Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
4 Sept 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of Work for this tender is "Any work involving supply , Installation , Testing and Commissioning of CCTV surveillance system using Fixed/Bullet/Dome/PTZ type camera."
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Two years warranty will be started after successful completion of the work and extended warranty /CAMC will be starting after expiry of two years warranty.
Provision of CCTV Cameras at Manned Non-Interlocked LC Gates over Howrah division.
SDSTE-CCTV-LC-GATE-HWH-26~ER
SDSTE-CCTV-LC-GATE-HWH-26
Open
Works - General
6 Months
Howrah, West Bengal
₹0
₹3.6 L
4 Sept 2026
14 Aug 2026
21 Aug 2026
50 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,79,16,103.01 | ||
| — | — | — | 11,85,536.88 | ||
| "Supply, Installation, Testing and Commissioning of Full HD Fixed Bullet type IP Colour Cameraalong with 128GB or Higher SDCard, housing and mount and all accessories required for installation purposes per RDSO Spec No RDSO/SPN/TC/65/2021 Version 6.0 with Amendment No. 1 & 2 or latest.Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 88.00 | — | — | |
| — | — | — | 3,46,577.44 | ||
| "Supply and installation of SIM based Router as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 88.00 | — | — | |
| — | — | — | 12,945.73 | ||
| "Supply and installation of 1 KVA Online UPS with half an hour backup as per annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 1.00 | — | — | |
| — | — | — | 9,86,344.04 | ||
| " Supply, installation and testing of 8 port PoE Managed switch as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(a) Supply of 8 port PoE Managed switch as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(b) Installation of Network switch | — | 44.00 | — | — | |
| — | — | — | 23,48,350.84 | ||
| "Supply installation testing and commissioning of pure sine wave 1275 VA Inverter with minimum 12V/180 AH Maintenance Free Battery JISC : 8702 ( Pt. I,II,III) without trolly Specification : 1. IGBT-PWM with inbuilt isolation transformer. 2. Input power single phase 160V- 260V sinewave, 50 hz, output power single phase 230V/+- 2% , 50Hz, 3. It should have overload protection with Auto Reset. 4. Battery should have 04 years warranty. Make: Luminous/APC/Delta/Microtek or betterInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 44.00 | — | — | |
| — | — | — | 1,56,640 | ||
| "Supply, testing and demontration of 600 VA UPS as per annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 44.00 | — | — | |
| — | — | — | 16,86,257.32 | ||
| "Supply and installation of Service Terminal (For Station) as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 44.00 | — | — | |
| — | — | — | 51,07,888.72 | ||
| "Supply, installation, testing and commissioning of Network Video Recorder with minimum 4 Channel for CCTV System (Including all accessories) and monitoring system as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(a) Supply of Network Video Recorder with minimum 4 Channel for CCTV System (Including all accessories) as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of Survelliance Hard Disk 8 TB as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c ) Supply of wireless mouse as per Annexure INSPECTION : CONSIGNEE.""(d) Supply of Standard computer Keyboard (Wireless) for CCTV monitoringsystem as per Annexure INSPECTION : CONSIGNEE.""(e ) Supply of 22 inch Monitoring Display with accesories as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(g) Supply of HDMI cable as per annexure.Inspection by Consignee."(h) Installation , testing & commissioning of CCTV recording system and monitoring system with display unit along with accessories at Stations via suitable arrangement as per site requirements | — | 44.00 | — | — | |
| — | — | — | 70,100 | ||
| Installation , testing & commissioning of CCTV recording system and monitoring system with display unit along with accessories at Division Headquarter via suitable arrangement as per site requirements | — | 1.00 | — | — | |
| — | — | — | 9,87,925.5 | ||
| Supply and laying of CAT-6 Cable "(a) Supply of STP LSZH CAT-6 Cable as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of UTP CAT-6 cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly. Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (the clamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site." | — | 13725.00 | — | — | |
| — | — | — | 1,76,000 | ||
| Supply and laying of Power Cable 3 X2.5 SQ. MM(a) Supply of Power Cable 3 X2.5 SQ. MM as per IS-694 . PVC insulated flexible 3 core x 2.5 sq. mm multistrand power cable provided for display boards shall conform to specification no IS694: 1990 reaffirmed 1995 or latest of reputed brand. Inspection: Consignee"(b ) Laying of Power cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly. Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site." | — | 2200.00 | — | — | |
| — | — | — | 1,21,440 | ||
| Supply and laying of 1 x 10 Sq.mm. (Red/Black) multi strand copper power wire"(a) Supply of 1 x 10 Sq.mm. (Red/Black) multi strand copper power wire as per IS: 694:2010 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and testparameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in- charge.Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b ) Laying of Power cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly. Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site." | — | 880.00 | — | — | |
| — | — | — | 2,59,272 | ||
| Supply and fixing of PVC conduit pipe(a) Supply of 25 mm PVC conduit pipe as per ISI grade. INSPECTION CONSIGNEE.(b) Execution/fixing of PVC conduit pipe on wall/Shed or as per site requirement including supply of all fixing materials & accessories by contractor. Returning the left- over material to the railway store. | — | 5200.00 | — | — | |
| — | — | — | 3,72,728.84 | ||
| "Supply and installation of Wall mounted 19"", 9U Rack with fan and 6 no sockets and accessories as per annexure INSPECTION : CONSIGNEE. " | — | 44.00 | — | — | |
| — | — | — | 2,56,872 | ||
| "Digging of trench 1.2 Mtrs. deep from rail flange/ road leveland 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed." | — | 924.00 | — | — | |
| — | — | — | 4,20,420 | ||
| "Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee." | — | 1716.00 | — | — | |
| — | — | — | 4,14,054 | ||
| Supply and laying of 40 mm dia permanently lubricated HDPE telecom: ducts "(a) Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(b) Laying of HDPE duct in trench and its protective work as per direction of site engineer | — | 6.00 | — | — | |
| — | — | — | 56,203.4 | ||
| "Supply and installation AnnexureINSPECTION CONSIGNEE." | — | 44.00 | — | — | |
| — | — | — | Complete | ||
| — | — | — | 6,62,640 | ||
| Supply and laying/fixing of GI pipes"(a) Supply of Medium class GI pipes 50 mm dia(3.6 mm thickness) as per IS 1239 ( Part 1 ) : 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends.Inspection: Consignee""(b) Laying & Fixing of Medium class GI pipes 50/100 mm dia(3.6 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends.Inspection: Consignee" | — | 1320.00 | — | — | |
| — | — | — | 4,53,041.6 | ||
| Cuting of the Platform surface (Tile/Slab/Mastic Pad/Concreat/road) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform (after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" ) as per site supervisor | — | 1760.00 | — | — | |
| — | — | — | 3,51,911.8 | ||
| Comprehensive Annual Maintenance Contract for 44 Nos NVRs for 5 Years | — | 5.00 | — | — | |
| — | — | — | 5,92,768.45 | ||
| Comprehensive Annual Maintenance Contract for 88 Nos Bullet cameras for 5 Years | — | 5.00 | — | — | |
| — | — | — | 8,43,128.65 | ||
| Comprehensive Annual Maintenance Contract for 44 Nos service terminal(Station) for 5 Years | — | 5.00 | — | — | |
| — | — | — | 47,055.8 | ||
| Comprehensive Annual Maintenance Contract for 01Nos service terminal (HQ) for 5 Years | — | 5.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureCCTVLCGate.pdf
ATTACHMENT
CheckListAnnexItoVIIIUPDATED_1.pdf
ATTACHMENT
AnnexureIX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI_1.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCC-2022-Updated-25.09.24.pdf
ATTACHMENT
VICINITYOFUNDERGROUNDCABLE-
ATTACHMENT
TermsofPayment.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4_c.pdf Labour Cess
ATTACHMENT
GCCwithCorrectionSlips1to10.pdf
ATTACHMENT
Updatedtenderdocument_cc.pdf
ATTACHMENT
ACS-11_compressed.pdf
ATTACHMENT
OnlineBG1.pdf
ATTACHMENT
MaintenanceschCCTV.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4_c.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .