Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC P 45 JOGENDRA GARDEN KOLKATA 700078 | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹46.7 L+₹4.1 L (9.70%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.8 L+₹4.2 L (9.89%)Rejected-Finance FLAT NO B2 2 13 RABINDRANAGAR M B ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹48.4 L+₹5.8 L (13.7%)Rejected-Finance B4 60 1 NEW SANTOSHPUR THANDER PARA STATION ROAD 24 PARGANAS SOUTH PIN 700142 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 700142 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹48.5 L+₹5.9 L (13.8%)Rejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
8 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO BLDG NO T-574, T-573, T-668A, T-370, T-652 AND T-575 AT 1803 PNR UNIT UNDER GE (FW) KOLKATA
2024_MES_637005_1
8210/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹78,000
1 Mar 2024
11 Jan 2024
9 Feb 2024
11 Jan 2024
8 Feb 2024
25 Jan 2024
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling of boarding, any description, fixed in any position with screws etc all as directed.
M&L for providing and fixing Gypsum Board 600x600x12mm thick in ceiling fixed with screw in anodised aluminium snap grid frame work for false ceiling as per manufacturers instructions with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for. complete all as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade FE 410 W grade E 250 quality A. complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings etc complete all as directed.
S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and as directed.
S&F Plain, 0.71 mm thick Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) etc complete all as specified and as directed.
M&L for Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specified and directed by Engineer-in-charge.
Dismantling of floor hearth, wall tiling incl cement mortar bedding( but not backing) removing of serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for dark shade verified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over laid screed bed 20 mm thick CM 1:6 complete all as specified and directed.
M&L for dark shade verified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over laid backing coat 10mm thick plaster CM 1:4 complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-1(using 20mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and as directed by Engineer-in-charge..
S&F for anodised aluminium powder Coating minimum thickness of powder coating 50 micron to frame for doors, windows, ventilators, Almirah, cup board and partition walls with one or more rebates including joining cleat for fixing . rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.
S&F for Anodised aluminium powder coating 50mm micron window and ventilator shutters, cup board shutter for sliding type etc fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F for 4.8 mm thick plain sheet glass, ordinary quality and glazing rubber beading in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing etc complete all as specified and as directed.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site etc complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for 100mm thick cement concrete type B-1, 1:2:4 using 20mm graded aggregate in floors finishing cement concrete surface even and smooth using extra cement complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-22mm thick over 20 mm thick cement screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed.
M&L for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over laid backing coat 10 mm thick CM 1:4 complete all as specified and directed.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing over 20 mm thick screed in CM(1:4) etc complete all as specified and as directed.
M&L Preparing old decorated Plaster Surfaces of Wall and applying One Coat of oil bound distemper complete all as specified and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
All as per item No 26 but one coat etc complete all as specified and as directed.
M&L Preparing old Wooden Surfaces of any description not otherwise described over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIC WORKS) Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site complete and make good the disturbed surface as existing complete all as specified and as directed.
Taking down of old Submain wiring upto 10 sqm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M & L for Modular point wiring with 1.5 sqm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sq mm (nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan/ceiling fan/ call bell point point controlled by one switch Note : Wiring Color code i.e. Red/Yellow/Blue for Phase, Black for neutral and Green for earth shall be maintained.( for concealed wiring chase cutting will be measured and paid seperately.)
All as per item No 31 above but for one three pin socket outlet on same board
All as per item No 31 above but for one three pin socket out let 5 amps on independent board.
S&F Modular switch 1 way 6A, 1 module complete all as specified and as directed.
S&F Ceiling rose surface type 3 terminals 65x20mm compelete all as specified
S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S&F Switch socket outlet 3 pin 6 amp' flush type complete all as specified and directed.
S & F Modular Bell push 6A, 1 module complete all as specified and directed.
S&F Bell Multi Music type complete all as specified and directed.
S&F Fan step regulator, 120W - 2 module complete all as specified and directed.
S&F White cover plate with frame, 1 module complete all as specified and directed.
S&F White cover plate with frame, 2 module complete all as specified and directed.
S&F White cover plate with frame, 3 module complete all as specified and directed.
S&F White cover plate with frame, 4 module complete all as specified and directed.
S&F White cover plate with frame, 6 module complete all as specified and directed.
S&F White cover plate with frame, 8 module complete all as specified and directed.
S&F Metal flush box 1/2 module complete all as specified and directed.
S&F Metal flush box 3 module complete all as specified and directed.
S&F Metal flush box 4 module complete all as specified and directed.
S&F Metal flush box 6 module complete all as specified and directed.
S&F metal flush box, 8 module complete all as specified and directed.
M & L for point wiring with 4.00 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade for 3 Pin socket outlet 15 Amps on independent board with PVC conduit (ISI Marked) medium duty not less than 20mm dia with accessories such as elbow, tees,internal & external bend etc. of suitable size including continuous earth wire FRLS PVC insulated 4.00 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified. Note : 1) Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. 2) Necessary chase cutting for conduits if requires, shall be measured & paid separately under respective items in this schedule.
S&F modular Switch Socket combination outlet 6 pin 16 Amps flush type complete all as specified and directed.
S&F AC Starter of 32 Amps Alongwith Plug top complete all as specified and directed.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring.Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.
Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity 40 to 63 AMP in the MCB DB complete with connection testing and commissioning as specified and directed.
S&F sheet metal enclosure of Bus bar of SPN 8 way complete as specified and directed. .
S&F sheet metal enclosure of 12 way TPN DB complete as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning TPN /FP 40 to 100 AMP as specified and directed.
Cutting chases for concealed conduit wiring and making good, cutting not exc 10 cm girth complete as specified and directed.
Supply and fixing squre shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete as specified and directed. .
S & Fix Energy efficient light fitting (LED ) Batten fitting 2FT (Cute linea,surface &wall mounting LED 2ft batten with extruded synthetic housing,3" X3" PVC block 2 Nos,Lamps,driver,connector etc incl hanging arrangement with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting through suitable size flexible PVC pipe making good to wall for old fitting including taking down old fitting of complete all as specified and directed. Make Crompton Cat No CCS-102-10-30-SL-DP-NWH or equivalent in Bajaj/CG
Supply and fixing LED lights fitting 1x 20W 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete as specified and directed.
S & F Building security light 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified and directed.
Supply and fix exhaust fan copper winding of sweep 300mmade of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, complete as specified and directed.
Taking down ceiling fan 1200 mm to 1400 mm sweep of any make sealing cable ends, dismantling blades , cleaning thoroughly with kerosene oil including filling cavities with filler etc, complete with painting of two coats, hanging the ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S SRINIVASA CONSTRUCTION
Piu Projects
DGR CONSTRUCTION
MODERN AGENCY
MARUTI ENTERPRISES
M/S SHRI P K ACHARJEE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .