Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 CrRejected-Finance 16 5 KUMARASAMY STREET KALAIMAGAL SCHOOL ROAD ERODE | ₹22.0 Cr | L1 | Rejected-Finance Higher Quote |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically non compliant and substantially non responsive |
| Sl No | Description | Qty | Unit | vivek vijay and company |
|---|---|---|---|---|
| 1.00NOTE: 1.Evaluation will be done by excluding Provisional sum and GST Amount 2.GST is to be quoted @ rate of 18% 3.The bid price shall be net of Input Tax credit availed by the bidder i.e., base price shall not have any GST component in it. In effect, the clause 171 of GST, that is, the Anti-Profiteering Rule shall be adhered to. A self-declaration from the bidder on clause 171, shall be attached with the invoice. The output GST paid by the bidder shall be reimbursed by CHENNAI METRO RAIL LIMITED on production of the documentry evidence | ||||
| 1.01 | SUMMARY OF PRICE BID | 1 | Nos | 22,03,14,778.89 ₹26.0 Cr |
Updated dates
Tender Value
₹20.8 Cr
EMD Value
₹20 L
Closing Date
20 Mar 2026, 3:00 pmClosed
Director (projects) for Managing Director
Metros,CMRL, Nandanam, Chennai-600 035
Construction of High Rise Building Near Arumbakkam Metro Station Consisting of Basement and Stilt Floor (4 Tier Mechanical Car Parking System) Plus 7 Floor of Commercial Space Including Structural, Architectural, MEP, Signages, HVAC, Lifts, Facade
2026_CMRL_897054_1
CMRL/CP/TDR-63-CON/2026
Open Tender
Civil Works - Buildings
550 days
chennai
Please refer Tender documents.
10 documents required · 10 mandatory
₹32,000
Yes
CHENNAI METRO RAIL LIMITED
₹20 L
Yes
Chennai
27 May 2026
5 Feb 2026
20 Mar 2026
5 Feb 2026
20 Mar 2026
4 Mar 2026
5 Feb 2026 - 17 Feb 2026
17 Feb 2026
NOTE: 1.Evaluation will be done by excluding Provisional sum and GST Amount 2.GST is to be quoted @ rate of 18% 3.The bid price shall be net of Input Tax credit availed by the bidder i.e., base price shall not have any GST component in it. In effect, the clause 171 of GST, that is, the Anti-Profiteering Rule shall be adhered to. A self-declaration from the bidder on clause 171, shall be attached with the invoice. The output GST paid by the bidder shall be reimbursed by CHENNAI METRO RAIL LIMITED on production of the documentry evidence
SUMMARY OF PRICE BID
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
ARCHITECTURAL ITEMS:
PAVEMENT FOR FOOTPATH
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
BLOCKWORK
200THK - Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
100THK - Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Parapet Wall at Upper Terrace Floor- 230THK - Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Compound Wall Construction: 230THK - Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and applying 12mm thick plaster in cement mortar 1:4 (1 cement : 4 fine sand); to exposed surfaces of concrete and masonry works ,keeping the surface rough (with sponge) to receive finishing work or as required to receive specified architectural finish, to correct line, plumb and level to external faces of walls, including rounding off corners wherever required smooth rendering, including raking out joints, hacking concrete surfaces, preparing junctions of concrete / masonry by neat cleaning, pointing / grouting using non-shrink mortar and further grouting junctions by pressing square crush aggregate; preparing jambs, sills, grooves, pattas, wattas, rounding of corners, etc.including provision of corner beads to prevent accidental damage at all levels, heights, locations with all lifts and all leads, including scaffolding, cost of materials, labour, cleaning of surfaces, curing, etc. to complete as per specifications and as directed by the Engineer.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
PAINTING @ COMMON AREAS
Interior Painting in Common Areas:Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime
Exterior Painting in Common Areas & Parapet at Terrace Floor: Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm sqm 223.60
FLOORING
Lift Lobby Area: Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm.
Stair Case area: Lift Lobby Area: Providing and laying (including Thread,landing area & skirting) gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm.
Staircase Riser: Providing and fixing machine cut, mirror polished 18 mm thick Granite stone for skirting, risers of steps of approved colour in required size, design and patterns, all complete as per the architectural drawings, over 12mm thick base Cement mortar (1:3) laid and jointed with neat cement slurry mixed with pigment to match the shade of garnite stone including lead and lift at all levels and for all heights and location complete as per specifications and drawings as approved by the engineer.With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm.With granite stone of area less than 0.50 sqm.
Electrical Room Floor: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
WALL CLADDING
Lift Wall Granite Cladding: Providing and fixing dry cladding upto 10 mtrs height with 18mm thick Gang saw cut polished granite stone of approved colour in required size, design and patterns, fixed to structural steel grame and or with the help of steel clamps/cramps, pins, etc., sealing the joints with approved weather sealant as approved drawing and direction of engineer. Rates to be inclusive of all cramps, clamps, pins, etc.,
FALSE CEILING @ COMMON AREA(LOBBY)
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles
STRUCTURAL GLAZING ON THE THREE FACES OF STRUCTURE
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
SS HANDRAILS at Staircase
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
DOORS @ COMMON AREAS
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).
WINDOWS @ COMMON AREAS(STAIRCASE)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
ROLLING SHUTTERS
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. a)80x1.25 mm M.S. laths with 1.25 mm thick top cover total 3 rolling shuttes of size 1.3(w)x4.1(h)
Extra for providing mechanical device chain and crank operation for operating rolling shutters.A, Exceeding 10.00 sqm and upto 16.80 sqm in the area
Design, Supply, Erection, Testing and commissioning of passenger lift with Stainless Steel finish Car enclosure to carry 13 passengers of 884kgs of machine roomless, synchronizing motor - Gearless VVVF controller in the existing lift well / shaft having minimum speed of 2 m/sec with a total travel of 30 (Approx) mtrs. Stilt plus 7 upper floors, servicing 7 stops and 7 landings on the same side with / without attendant operation. The car cabin wall shall be by the combination of MS base plate of 1.5mm thick over which skin plate of 0.6mm etched / scratch proof stainless steel is affixed and bonded to farm a over all wall thickness of 2.1mm and with all necessary safety features and in accordance with Lift Service particulars, General / Technical Specification, special condition etc. The design pattern shall be of combination of etched / scratch proof stainless steel and shall be as per Architect / Owner requirement and approval.
MECHANICAL CAR PARKING SYSTEM FOR 36 CARS
Four Tire Mechanical ventilated car parking for 36 cars - Design, manufacture, supply, installation, testing and commissioning of a fully automated mechanical ventilated car parking system for 36 cars, including complete system engineering, structural supports, control systems, safety devices, power and drive mechanisms, electrical works, trial runs, training of personnel and obtaining statutory approvals, all complete as per Employer’s Requirements and approved drawings.The system shall include 3 years warranty from the date of commissioning. After expiry of the warranty period, the Contractor shall provide Comprehensive Operation & Maintenance including supply of all spares, consumables and materials for a period of 3 years at 4% of the basic project cost per annum.
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
GENERAL
SITE CLEARANCE:
Site Clearance: Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
SURVEYING:
SURVEYING - Carrying out detailed topographical survey of the vacant land using Total Station / DGPS equipment, establishing survey control points with reference to permanent benchmarks, recording all existing ground features, levels and spot levels at regular grid intervals of 3 m × 3 m, preparation of contour plan, site plan and level sheets, including demarcation of plot boundary, grid setting-out, traversing, computation, plotting, and submission of survey drawings in soft and hard copies in approved scale and formats (AutoCAD & PDF). The work shall include all labour, instruments, calibration, data processing, transportation, setting out materials, and incidental works complete as directed by the Engineer-in-Charge, in accordance with relevant IS codes and Employer’s Requirements.
STRUCTURAL ITEMS:
Providing confirmatory Geotechnical soil investigation works including mobilization of plant, machinery and manpower; setting out; drilling of two (2) nos. boreholes up to a depth of 40 metres each using rotary/percussion drilling methods through all types of soil/strata (including gravels, hard strata, weathered rock etc.); collection of disturbed and undisturbed soil samples at specified depths; conducting in-situ tests including SPT at 1.5 m intervals and at change of strata; core drilling and recovery in rock; preservation, labelling and transport of samples; laboratory testing including index and strength tests as required; preparation of bore logs; groundwater table observation; and submission of a detailed geotechnical investigation report including recommendations on allowable bearing capacity, settlement, pile capacity (if applicable), geotechnical design parameters and strata profiles, complete as per relevant IS codes and to the satisfaction of the Engineer-in-Charge.(Rate to include all labour, materials, equipment, transportation, testing, reporting and incidental works complete.)
Temporary Shoring: Sheet Piling
Temporary Shoring with 'Z' section MS sheet piles side by side in all kinds of soil mechanically or manually as per approved drawings with contractor's own arrangement complete in all respects and removal of sheet piles after completion of the work as directed by engineer in-charge (Note - Payment will be made as per actual driven lemgth of Pile)
RCC Piling Works:
RCC Piling Works 750mm DIA Pile including Boring: Piles:- Providing and installing cast-in-situ vertical bored piles of required depth as per approved GFC drawing with M30 grade of reinforced cement concrete using Portland slag cement including all operations such as mobilization, installation and shifting of piling rig etc., in all soil strata, rock grade V, IV & III, road, footpath including boulders and kankar (other than in rock grade GI and GII). The item includes disposal of earth, muck, slush released from piles, top cut portion of pile at contractor's dumping ground with all leads and lifts .Disposal / utilization of the excavated soil as per contractors own arrangements / choice including loading , transportation, unloading to any lead with all necessary safety / environmental compliances measures as defined in the relevant section of the contract document. The rate shall include all operations required for installation of pile such as installation of rig, shifting of hydraulic rig, construction of approach temporary road / bridge for pilling rig etc.The cost shall also include the cost of empty boring with MS temporary liner as per site requirement. The Cost shall also include cutting/chipping of pile up to cut off level or up to good concrete and built up of pile up to required level( as per drawing). Rate shall include cost of using required dosage of admixture in concrete for obtaining required workability as per approval of Engineer in Charge. Cost for temporary casing shall be included in the rate.Piling / Drilling shall be done by use of hydraulic rotary rigs using temporary casing till required depth(Min 4.5 Mtr ). Bentonite/Polymer slurry to be used as directed by the Engineer-in-charge. The item shall also include the cost of bentonite/Polymer to be used for stabilisation of bore. Bentonite/Polymer shall be allowed with the specific approval of Engineer based on the soil strata. Socketing shall be as per specification and the decision of Engineer shall be final . Reinforcement works shall be paid seperately Note: Pile measurement shall be from cut-off level to founding level as shown in the drawing
BORED PILE FOUNDATION 450mm DIA: Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles
NDT test pile
Conducting Cross Hole Sonic Logging test and report submission - for 25% of executed Piles or as per relevant codes
Pile integrity test for 100% of executed piles
Initial Pile Load Test -VERTICAL: Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 50 tonne and upto 100 tonne Safe capacity: Initial test (Test Load 2.5 times the Safe capacity)
Initial Pile Load Test - LATERAL: Lateral load testing of single pile in accordance with IS : Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile : Above 50 tonne and upto 100 tonne capacity pile
EARTH WORK:
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
Excavation
Dewatering by pumping including hire and running of pumps, labour, fuel, power, pipes, hoses and accessories, maintaining dry condition during execution of basement works.
WATER PROOFING WORKS:
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm per coat
Exterior Surface of Retaining wall + Interior Surface of Sump
For horizontal surface one coat @1.10 kg per sqm.
Base slab of Sump
Water Proofing at Upper Terrace: Providing and laying integral cement-based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a. Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with + treatment. b. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. d. Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. d. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. "all above operations to be done in order and direct and specified by the Engineer in charge." (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:with average thickness of 120 mm and minimum thickness of khurra at 65mm
PLAIN CEMENT CONCRETE: Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. All works upto stilt level. Concrete of M15 grade with minimum cement content of 240 kg /cum.
stormwater drain
Basement Raft slab including Sump base slab
Compound Wall - Plinth Beam
REINFORCED CEMENT CONCRETE WORKS M30 Grade:
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate erived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M30 grade with minimum cement content of 350 kg /cum. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
SUBSTRUCTURE & FOUNDATION WORKS:
Pile cap
Pile Cap
Raft slab
Raft slab
Sump Wall
EFFULENT TANK - BASE SLAB
EFFULENT TANK - WALL
EFFULENT TANK - COVER SLAB
Sump Wall - WALL
ROOF BEAM
Column & Shear Wall
Lift Pit
RC WALL
RC SLAB
Stair Case
MID LANDING
FLIGHT
Retaining wall
Retaining wall
Basement Roof Slab
Sump Cover Slab
Common Area
Basement Roof Beam
COMPOUND WALL
COLUMN
REINFORCED CONCRETE WORKS: SUPER STRUCTURE M30:
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate erived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M30 grade with minimum cement content of 350 kg /cum. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto upper Terrace level: Concrete of M30 grade with minimum cement content of 350 kg /cum
beam & column
PT Beam at All floors
RC BEAM at All floors
TIE BEAM AT LINTEL LEVEL OF COMMON AREAS
Column
Stair Case
MID LANDING
FLIGHT
PT SLAB
RC SLAB
OVER HEAD TANK- 1 - RC WALL
OVER HEAD TANK 2 - RC WALL
OVER HEAD TANK 1- Cover Slab
OVER HEAD TANK 2 - Cover Slab
OVER HEAD TANK 1 - Base Slab
OVER HEAD TANK 2 - Base Slab
STORM WATER DRAIN - M25:
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum
BASE SLAB
RC WALL
RC COVER SLAB
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Structure.-Thermo -Mechanically treated bars of grade FE-500D or more.
Pile cap
Retaining wall
Ug sump, OHT,Tanks
storm water drain
Beam & column
PT SLAB
PT BEAM
COMPOUND WALL - COLUMN
COMPOUND WALL - BEAM
COMPOUND WALL - COLUMN
Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (Gl corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the PMC / Employer. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Engineer-in-charge Supply & execution of post tensioning work shall be carried out by approved specialized agency, with their own design, equipment, accessories & skilled manpower for satisfactory completion of work as per approved drawings. The contractor shall have minimum 5 years experienced technical staff for proper monitoring, ensuring & certifying the correctness of entire prestressing operations. Prestressing work shall be duly tabulated and report shall be submitted. Item also to include the required scaffolding etc. including marking the PT strand path locations for easy identification etc. all complete to the entire satisfaction of PMC/Employer.
PT SLAB Tendons
PT BEAM Tendons
CENTRING & SHUTTERING:
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.,
Foundation
Retaining wall
Basement Raft slab
SUMP - WALL
columns
ROOF SLAB
OHT 1 - SLAB
OHT 1 - RC WALL
OHT 2 - SLAB
OHT 2 - RC WALL
COMOUND WALL
COLUMN
PLINTH BEAM
TIE BEAM AT TOP
Earthwork backfill
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Earthwork backfill
Sunken filling in Toilet of Common Area
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
MS GATE AT MAIN ENTRANCE
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes
Screed Concrete: 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SANITARY FIXTURES & FITTINGS
Supply ,Fixing, testing and commissioning of white vitreous china Wall Mounted Type European Water Closet including C.P. bolts, nuts, C.I. chair ( painted with two coats of enamel paint over a coat of primer ) or other hanging arrangements, bakelite / poly propylene seat & cover with C.P. hinges & rubber buffers, complete with all accessories. Including cutting & making good the walls & floors wherever required. Make: Parryware
Supply ,Fixing, testing and commissioning of Concealed Cistern (3/6 LPF) with Push plate suiable for wall mounted EWC. The works shall include cutting and making good the walls & floors complete as required. Make: Parryware
Supply ,Fixing and testing of 15 mm CP brass Health Faucet of approved make with necessary CP flexible hose 1000 mm long nozzle, CP wall flange etc., complete. Make: Parryware
Supply ,Fixing, testing and commissioning of 15 mm dia C.P. brass 2 Way Cock With C.P. Wall Flange of approved quality and making good as required. Make: Parryware
Supply, Fixing, testing and commissioning of white coloured vitreous china Regular Oval / Rectangular Wash Basin with brackets / G.I. rag bolts and nuts painted. The work shall include cutting / chasing and making good the walls and floors. Make: Parryware
i)Manualy operated pillar cock for wash basin
ii)32mm dia CP brass waste coupling
iii)15mm dia CP brass angle valve
iv)15mm dia flexible cold connection pipe
Supply & Fixing, testing and commissioning of Urinal basin with automatic flushing systems opearating AC power supply for urinal to ensure pre-flush & flushing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning. Including necessary wall cutting / chasing and making good, as required. Make: Parryware
Supply, checking, storing & fixing 15 mm. dia exposed Concealed stop cock with 1/2" outlet with wall flange and all accessories. (For Water Inlet control)
Fixing of C.P brass Toilet paper holder with PVC rawl plug & C.P. brass screw complete as required.
Fixing of C.P. brass Twin coat hook with PVC rawl plug & C.P. brass screw complete as required.
Fixing of Soap Dish Holder with necessary fixing with SS screws and clamps etc., complete.
Fixing of of Hand dryer of approved make or equivalent with necessary accessories etc all complete as directed by the Engineer-in-charge.
SOIL WASTE AND RAIN WATER PIPES
Supplying, fixing, testing and commissioning of PVC Soil, waste and ventilating pipes (SWR) conforming to IS:13592 /1990 -Type B with rubber ring (conforming to IS : 5382) joints inclusive of all necessary specials like bends, tee, offsets, door bends, junctions, cowls etc., laid under floor /fixed on walls and in pipe shaft with proper pipe support like brackets, hangers, MS grip bolts etc., complete. The support shall be painted with two coats of enamel paint.
INTERNAL
40 mm for Wash basin drains
50 mm for Urinal drains
75 mm Waste pipe
110 mm soil pipe
110 mm Rain pipe
VERTICAL RISER
110 mm (Rain water - vertical)
110 mm (soil - vertical)
75 mm (waste - vertical)
Supplying, installing, testing and commissioning of Special type bathroom grating. outlet fixed on a bed of cement concrete with standard size stainless steel type grating with cover (Heavy duty type) etc., complete. The cost shall include.
Supplying, installing, testing and commissioning of PVC Floor trap with 110mm dia inlet and 75mm dia. outlet fixed on a bed of cement concrete with 150 x 150mm stainless steel type grating with threaded cover (Heavy duty type) etc., complete. The cost shall include Cockroach Traps.,
Providing and fixing Heavy class S.S. grating with cockroach/mosquito proof S.S. strainer of Chilly or equivalent make, as approved, (inch cockroach trap) including setting in floor with cement mortor to match with floor finish as per architect requirements.
Fixing of the C.I khurra incl 100x300mm Bell Mouth Roof Drain within the water proofing fill above roof and taking out rain water outlet by fixing an elbow to the khurra outlet and making connection to the rain water down coming pipe, painting the grating with one coat of primer and two coats of black enamel paint.
INTERNAL WATER SUPPLY SYSTEM
Supplying, installing, testing & commissioning Chlorinated Polyvinyl Chloride (CPVC) pipes, SDR 11 as per IS 15778: 2007 & fittings as per ASTM D2846 / D2846M - 14, both of approved make having thermal stability for hot & cold water supply make with Solvent cement joint, including all CPVC plain & brass threaded fittings such as bends, elbows, tees, sockets, unions, plugs etc., including fixing the pipe., including necessary drilling holes, chasing walls and making the same good in as directed by the Engineer in-charge.
Cold Water - Internal
a) 20 mm dia
b) 25 mm dia
Flush Water - Internal
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
DWS Terrace Ring Main (UPVC)
a) 40 mm dia OHT Outlet
b) 50 mm dia OHT Inlet
FWS Terrace Ring Main (UPVC)
a) 50 mm dia OHT Outlet
b) 65 mm dia OHT Inlet
DWS Riser (UPVC)
a) 25 mm dia OHT Outlet
b) 32 mm dia OHT Outlet
c) 40 mm dia OHT Outlet
d) 50 mm dia OHT Inlet
FWS Riser (UPVC)
a) 32 mm dia OHT Outlet
b) 40 mm dia OHT Outlet
c) 50 mm dia OHT Outlet
d) 65 mm dia OHT Inlet
Supplying, installing and testing and commissioning of approved make PN 16 class GM ball valves with necessary unions etc., complete in all respect.
a) 32 mm dia (Screwed ends)
b) 40 mm dia (Screwed ends)
c) 50 mm dia (Screwed ends)
Supplying, installing, testing and commissioning PN 16 CI butterfly valves with standard lever conforming to BS 5155 with necessary connecting 'fittings like flanges, nuts and bolts etc., complete in all respect.
a) 65mm dia
b) 100mm dia
Providing and fixing GM Air release valve inch 25 to 20 reducer, double acting, of approved make, having 2 chambers with ebonite ball, small and large orifices with isolating stop screw down valve, GM seats, high tensile brass spindle with cap, conforming to standard water works pattern. Flanges as per IS : 15381, flat faced and drilled, complete of the following nominal bore (NB) size:
INTERNAL SUMP AND OHT PUDDLE FLANGES
Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy duty D.I frame and cover for under ground water tank complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table F with thickness of wall ratio 1:2, accessories comprising of the following
Fire UG Tank - 1 ( 1 Nos )
Approx. Sise = 11.2m (Length), 4.70m (Width) & 1.50m (Depth, Including 0.300m free board)
1a) MS manhole frame & cover (16G Sheet) with locking facility.
1b) Inlet puddle flanges
100 mm Dia, Tanker Inlet
50 mm Dia, Borewell Inlet
32 mm Dia, Metro Inlet
1c)outlet puddle flanges
80 mm Dia, OHT Inlet
1d) vent pipe 100mm dia.
1e) Overflow Pipes 100mm dia.
1f) Sleeves for level controllers (25 mm dia.)
1g) 65mm Dia, Spare
1h) 100mm Dia, Fire to Fire Interconnect
1i) PVC Rungs
Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy duty D.I frame and cover for under ground water tank complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table F with thickness of wall ratio 1:2, accessories comprising of the following
Fire UG Tank - 2 ( 1 Nos )
Approx. Sise = 11.2m (Length), 4.70m (Width) & 1.50m (Depth, Including 0.300m free board)
1a) MS manhole frame & cover (16G Sheet) with locking facility.
1b)outlet puddle flanges
80 mm Dia, OHT Inlet
1c) vent pipe 100mm dia.
1d) Overflow Pipes 100mm dia.
1e) Sleeves for level controllers (25 mm dia.)
1f) 65mm Dia, Spare
1g) 100mm Dia, Fire to DWS Interconnect
1h) PVC Rungs
Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy duty D.I frame and cover for under ground water tank complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table F with thickness of wall ratio 1:2, accessories comprising of the following
DWS UG Tank - 2 ( 1 Nos )
Approx. Sise = 2.20m (Length), 4.70m (Width) & 1.50m (Depth, Including 0.300m free board)
1a) MS manhole frame & cover (16G Sheet) with locking facility.
1b)outlet puddle flanges
65mm Dia, OHT Inlet
1c) vent pipe 100mm dia.
1d) Overflow Pipes 100mm dia.
1e) Sleeves for level controllers (25 mm dia.)
1f) 65mm Dia, Spare
1g) PVC Rungs
Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy Duty D.I frame for Overhead water tank, complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table with thickness of wall ratio 1:2, accessories comprising of the following.
Fire Over Head Tank - 1Nos
Approx. Size = 5.16m (Length), 4.40 (Width) & 0.9m (Depth, Including 0.300m free board)
1a) MS manhole frame & cover (16G Sheet) with locking facility.
1b) Inlet puddle flanges
50 mm Dia, Inlet
1c)outlet puddle flanges
100 mm Dia, OHT Outlet
1d) vent pipe (100mm dia.) with mosquito proof mesh
1e) Overflow Pipe 100 mm Dia
1f) 65mm Dia, Spare
1g) Drain pipe puddle flange - 50 mm dia
1h) Sleeves for level controllers (25 mm dia.)
1i) 100mm Dia, Fire to DWS Interconnect
1j) PVC Rungs
Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy Duty D.I frame for Overhead water tank, complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table with thickness of wall ratio 1:2, accessories comprising of the following.
DWS Over Head Tank - 1Nos
Approx. Size = 1.10m (Length), 4.40m (Width) & 0.90m (Depth, Including 0.300m free board)
1a) MS manhole frame & cover (16G Sheet) with locking facility.
1b) Booster outlet puddle flanges
40 mm Dia, OHT Outlet
1c)outlet puddle flanges
40 mm Dia, OHT Outlet
1d) vent pipe (100mm dia.) with mosquito proof mesh
1e) Overflow Pipe 100 mm Dia
1f) Drain pipe puddle flange - 50 mm dia
1g) Sleeves for level controllers (25 mm dia.)
1h) PVC Rungs
Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy Duty D.I frame for Overhead water tank, complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table with thickness of wall ratio 1:2, accessories comprising of the following.
Flush Over Head Tank - 1Nos
Approx. Size = 2.24m (Length), 2.25 (Width) & 0.9m (Depth, Including 0.300m free board)
1a) MS manhole frame & cover (16G Sheet) with locking facility.
1b) Inlet puddle flanges
65 mm Dia, Inlet
1c)outlet puddle flanges
50 mm Dia, OHT Outlet
1d) vent pipe (100mm dia.) with mosquito proof mesh
1e) Overflow Pipe 100 mm Dia
1f) Drain pipe puddle flange - 50 mm dia
1g) Sleeves for level controllers (25 mm dia.)
1h) PVC Rungs
EXTERNAL SEWERAGE SYSTEM
Providing and fixing testing and commissioning of PVC pipe for Risers to IS:13592 of SWR quality Type B, for stilt floor buried lines, external buried including all fittings like tees, elbows, bends, collars, coupling, brackets, clamps, fasteners, , etc jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste complete. The pipes shall be fixed properly aligned vertical with suitable Galvanised MS pipe clamps. Work to include making necessary holes in the masonary walls etc.. and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified.
Drainage Network
50mm dia
75mm dia
80mm dia
110mm dia
160mm dia
Supplying, fixing and testing of PVC Fabricated Gully Trap with top square bodies 300mm x 300mm, set in PCC 1:3:6 bed with RCC chamber and top cover shall be as indicated in the drawings, internal and external plastering 12mm thick in CM1:6 with water proofing compound including, excavating, refilling and ramming ,D.I (heavy duty type 40T) manhole cover with frames Heavy duty etc., complete
Soil Network
a) 450mm x 450mm (clear internal dimension)
b) 600x600 internal dimension Depth up to 600mm
a) 450mm x 450mm (clear internal dimension)
Constructing percolation pit of RCC structure , filling it with 300mm thick coarse sand layer of 1.5 to 2mm above 300mm thick gravel layer of 5-10mm size and boulders of 50mm to 200mm size of 300mm thick. Including Boulders of 100 -200 mm size at the top of about 100mm thick to avoid splashing at the entry Includes drilling auger bore hole of required dia and depth from pit bottom & fixing slotted pipe of required dia, filling the space between the pipe and bore hole with fine gravel of 3 to 6mm, covering the pit with R.C.C perforated cover slab & with bail plug at the bottom of the pipe. Includes earthwork excavation, getting out the excavated soil and returning the suitable soil as required for refilling, consolidating and disposal of surplus excavated soil within a lead of 50m, all complete as per specifications and as directed by the engineer in charge.
a) Size of Percolation pit ( 1.2m Dia X 3.5m deep)
b) 200mm dia slotted pipe-1nos of 6m deep
EXTERNAL WATER SUPPLY
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50mm dia SDR.11, ASTM CTS, and above 50mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50mm dia SDR.11, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc. with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 and restore the same in original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent conforming to ASTM F-4931 / 724. The solvent used shall be of approved make as recommended by the pipe manufacturer. Rate shall include necessary MS supports, clamps, hanging rods, Grip bolts and painting of all supports with 02 coats of ename paint etc., complete in all respect.
a) 50 mm dia
a) 65 mm dia
Construction of Valve Chamber with 230 mm best quality TM bricks in CM 1:4 over a bed of 100 mm thick PCC1:4:8, internal walls plastered smooth with necessary water proof compound in CM 1:3 and external walls plastered rough with sponge finish including curing with all necessary leads, backfilling around the cmaber and lift and providing heavy duty cast iron cover with frame with locking arrangements etc., complete including Heavy duty cast iron cover of size 750 x750
Supplying and fixing in position approved make PN 16 non-return valve conforming to IS 778 with unions etc., complete.
a) 32 mm dia
b) 40mm dia
Supplying and fixing in position approved make pot / Y - strainer complete conforming to IS standards etc., complete.
a) 50 mm dia
Supplying and fixing Level controller of approved quality and making good as required
a) Level controller (UG Sump & OHT)
b) 20 mm dia
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PUMPS & PUMPS ACCESSORIES
Supply ,Testing & Commissioning , of a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient Verical pump of SS-304 body,Impeller & Shaft mounted on a MSEP skid complete with all accessories as per manufacturer specifications. Accessories like ball valves, butterfly valves, non return valves, pressure gauges and dead end flanges on suction and discharge headers complete as required with all accessories integrated variable frequency drive for each pump, with inbuilt controller.
Multible VFD and controller to control the system requirement,.The pump logic controller shall have function such as Pressure control, Multi master function, Min time between start stop, Dry running, Low flow stop functoin, Fault primary sensor, Soft pressure built up Specific energy consumption,automatic pump alternations for run time equalization, Programmable number of starts/stops per hour to prevent pump hunting, Redundant primary sensor for pressure monitoring, soft pressure built-up. The system should be compatible with BMS through MODBUS.
Vertical in line multistage pump Motor enclosure shall be IP 55, motor insulation class shall be of Class F ,motor to be of efficiency IE3 and Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts, GI suction and Delivery manifold & float switch etc complete.
Pump capacity: 0.55 LPS/each
Pump configuration: 3Nos (2W+1S)
Head: 49MWC
Purpose: Domestic water Distribution
Location: WTP Pump room
Pump capacity: 3.35 LPS/each
Pump configuration: 2Nos (1W+1S)
Head: 40 MWC
Purpose: Flushing water Distribution
Location: STP Pump room
Supply, installation in position, testing and commissioning of electrically driven factory-assembled and tested non clog open impeller Dewatering pumps of approved make or equivalent, capable of discharging as mentioned below including fasteners, expansion bolts, nuts, with necessary accessories etc. all complete as directed by Engineer in Charge. Motor to be Hermetically sealed, capacitor-start type, with built-in overload protection; dry run protection; three-conductor waterproof power cable of length required, and with grounding plug and cable-sealing assembly for connection at pump.f) Motor enclosure shall be IP 68 in accordance with IS/IEC 60034 : Part 5 : 2000 (Reaffirmed 2007) and motor insulation class shall be of Class F in accordance with IS 1271:1985 (Reaffirmed 2007)/IEC 60085:2004.Pump motors shall be of Efficiency class IE 3 & operating range within 5 % of BEP. MODbus/BACnet port connectivity for interface to building automation system for On, Off, Run & alarm status of each pump.
(1 set =1W+1S)
Pump capacity: 4.5 LPS/each
Head : 55-60mwc
Solid Handling : 50mm
MOC : CI Body , Impeller & SS Shaft
Location: Raw sewage Transfer pump incase of STP failure.
Supply, installation in position, testing and commissioning of Horizontal centrifugal pump, Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have CI body, bronze impelleer. Pumps shall be provided with mechanical seal. The pump shall be suitable for auto / manual operation.
Pump capacity: 4.5 LPS/each
Pump configuration:2Nos (1W+1S)
Head: 55-60MWC
Purpose: Excess treated water transfer pump
Location: STP Pump room
Flow rate : 4.5 LPS/each
Pump configuration:2nos (1W+1S)
Head : 12-15MWC
Solid Handling : 10-12mm
MOC : CI Body & Impeller and SS Shaft
Maximum depth of sump:4m
Location: WTP & STP PUMP ROOM
Supply, installation, testing and commissioning of Class C GI pipe work for all pump suction / discharge line with common header complete with all fittings like elbow, tee, reducer, flange, union etc. conforming to IS:1239 (Part 1) for pipes and IS : 1879 (Part 1 to 10) for fittings including fixing in wall / ceiling / floor level, supported by galvanized clamps, hangers, vertical pipe support etc.
Cost shall be inclusive of all hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and then supply of the same shall also be included for rates under this head. Also rates including flusing and chemical cleaning of pipes.Charges for Labelling of pipe as per color schedule over painted surface of the pipes.
Location:pump room suction and delivery
150mm nominal bore
100mm nominal bore
80mm nominal bore
Supply installation testing and commissioning of Expansion bellows at pump delivery side with high tensile nylon/polyester cord body, high tensile nylon flanges with positive sealing, NEOPRENE rubber outer Cover & with Leakproof Abrasion resistant seamless lining of Rubber, Metal Retaining Rings embedded in body, including all necessary accessories like nuts, bolts etc. all complete of approved make as directed by the Engineer in charge.
150mm nominal bore
100mm nominal bore
Supply & installation of Suitable Cement concrete foundation with plaster for pumps
Supply, installation, testing and commissioning of Flanged butterfly valve of CI body SG iron rilson coated disc ,Working pressure not less than 16Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.
150mm nominal bore
100mm nominal bore
80mm nominal bore
65mm nominal bore
Supplying & fixing full way lever operated forged brass ball valve working pressure not less than PN30 with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
50mm nominal bore
Supply & fixing of flanged C.I. body Dual plate Check valve of rating PN16 including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required.
100mm nominal bore
65mm nominal bore
Supply, installation, testing and commissioning of dual flange Cast-iron 'Y'-Strainer (flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange / unions, nuts, bolts and wahsers complete as required.
150mm nominal bore
100mm nominal bore
80mm nominal bore
Supply, Installation, testing & commissioning of 100 mm dia dial type pressure gauge with pressure scale of 0 to 20 Kg / sqm. Coated rate shall be inclusive of isolation ball valve ,necessary fiitings etc.,
Supply, installation, testing and commissioning of capacitance rod type level controller for continious level monitoring of water tanks mounting top of the UG tanks .cost inclusive of cable from indicator to panel and display.Level controler should monitor the level of water tank and protect the pump from dry running .Necessary control logic should be consiered to make the system automatic as said above.
Level controller should be compitable for IBMS hook up for monitoring the level of tank
Location: Under ground tanks (Over all depth of tank:0-5.0m)
PLUMBING SYSTEM MCC PANEL
MCC PANEL FOR PLUMBING PUMP ROOM
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels.
PANEL-1:Location Plumbing plant room
Supply, Installation, Testing and Commissioning of Motor control center for Domestic water HNS 1 set(2W+1SB), and submersible drain pump 3set(1w+1s) , level indicator(1nos),complete with incomer, DOL STARTER bus bar, protective fuses, indicating lamps with interlock facility with bottom entry with foot mounting type complete with all accessories as per CEIG requirements. Before fabrication panel drawings get approved from electrical consultant.
Notes:
Provision of 20% for spare feeder
Provision shall be made to ensure system protection from dry running of the pump.
Provision shall be made for providing potential free contacts to all pumps starters for connection to BMS monitoring the ON/OFF/TRIP status.
Provision shall be made for auto operation of the pump.
PANEL-2:Location:Sewage treatment plant
Supply, Installation, Testing and Commissioning of Motor control center for Flushing water HNS system 1set (1w+1sb), Excess Treated Water transfer punp-1set(1w+1s), Raw sewage transfer pump(incase STP failure)-1set(1w+1s), level indicator(1nos), irrigation pump-1set (1w+1sb) submersible drain pump 3set(1w+1s) complete with incomer, DOL STARTER bus bar , protective fuses, indicating lamps with interlock facility with bottom entry with foot mounting type complete with all accessories as per CEIG requirements. Before fabrication panel drawings get approved from electrical consultant.
Notes:
Provision of 20% for spare feeder
Provision shall be made to ensure system protection from dry running of the pump.
Provision shall be made for providing potential free contacts to all pumps starters for connection to BMS monitoring the ON/OFF/TRIP status.
Provision shall be made for auto operation of the pump.
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
VENTILATION FANS
supply, installation and testing and commissioning of single/double skin cabinet inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip , Cowl piece with bird mesh and supporting arrangements. The fan motor shall be suitable for operating on 230V, 1 phase, 50Hz AC with ON/OFF Breaker ,The exposed Units should have Canopy for weather protection
Note. Vibration isolator detail shall be submitted before installation to consultants/PMC for approval
600 CFM-External static pressure -15 MM -without filter
supply, installation and testing and commissioning of CIRCULAR INLINE FAN with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip , Cowl piece with bird mesh and supporting arrangements. The fan motor shall be suitable for operating on 230V, 1 phase, 50Hz AC with ON/OFF Breaker
Direct driven PVC type Propeller fan ,rubber pad etc. complete,Each fan shall be complete with accesseries like finger proof steel wire guard at inside & Gravity louvers at outside of the fan .The fan shall be suitable for 230 volts ± 10% ,frequency 50Hz ± 5% , single phase AC supply ,Motor shall be with IP 54 protection .EFF1/ 2** efficiency & class F insulation,Suitable size of Cu flexible FRLS cable of length 5 meter with 3 pin plug top shall be included in the rates.
Toilet Exhaust fan - 650CFM
Supply, Laying & Termincation of 2C x 2Sqmm Armoured copper cable beween isolater to Exhaust Fan
DUCTS / GRILLS / DAMPERS
RECTANGULAR DUCT
Sheet Metal Work using with Ductmate/TDF Flanges for all sizes of the duct. Fabrication as per SMACNA Standards
All duct construction and installation shall be in accordance with SMACNA standards. In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts.required Bottom of the support rubber pad shall be part of this line item
All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes.
The Duct shall be fabricated with required splitters dampers ,turning vanes & cleats. Ducting works with all sizes made of TDF ( Up to 1200 mm width ) & slip-on flange joints ( for more than 1200 mm in width ) as specified in technical specs -Factory fabricated Ducting -- for 500** Pascal test pressure as per IS 655:2006 standards .
The Duct shall be supported with Hi-tech Supports at regular intervalas as mentioned in the technical specifications. Required ms supports shall be part of this line item. The bracing shall be as per ISS 655-1963. Supports for ducts shall be MS sections at 2.4m-distance apart up to 2250/1.2m distance apart for longer ducts Where duct and clamp are of dissimilar material, a gasket shall be provided in between. Contractor shall ensure that all ducts with insulation are not in direct contact with the hangers (duct supports). duct should be store in site ,all the duct should be coverd in both side .
Air balancing shall be done as required.
Duct testing shall be acrreid out as per Smacna standard , smoke test & pressure test ,as direcetd by client/PMC
Sheet Metal Ducting As per Specification.
DOOR LOUVER
Supply & fixing - Extruded Aluminimum powder coated louver without VCD with necessary GI Screw, bolt, nut & supports. ( colour for the grill to b conifremed by Arch/ PMC team before placing the order)
EXTERNAL LOUVER
Supply & fixing - Aluminimum powder coated LOUVER with BIRD SCREEN/MESH necessary GI Screw, bolt, nut & supports. ( colour for the Louvel to be confirmed by Arch/ PMC team before placing the order)required civil work like wall chasing ,wall cutout ,wall opening, and required finishing work shall be part of this line iem.
FRESH/EXHAUST AIR GRILL
Supply & Fixing of aluminium Fresh air/ Exhaust air powder coated grills with collar damber , color code shall be ar per architect approval
150x150-Grill with collar damper with plenum box
150x150-Grill with collar damper without plenum box
CANVAS
Supply Fabrication , and erection of Double canvas connection made out ,canvas should be atleast 2 hours fire rating required , fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc
UNDER DECK INSULATION
Supply and installation of Underdeck 25mm thickness insulation of class " O " Closed cell Nitrile rubber based elastomeric. The insulation shall have fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame as per BS 476 and also pass Fire Propagation requirement as per BS476 Part 6 to meet the Class ‘O’ Fire category as per 1991 Building Regulations (England & Wales) and the Building Standards (Scotland) Regulations 1990. Thermal conductivity of elastomeric nitrile rubber shall not exceed 0.035 W/m°K at an average temperature of 0°C. Material should be FM (Factory Mutual), USA approved. Moisture Diffusion Resistance Factor ‘µ’ value should be minimum 7000.this line item shall be use wherever its required to avoid the condensation.
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
FIRE PUMP ROOM EQUIPMENTS
Supply, Installation, Testing & Commissioning (SITC) of The Electrical motor driven pump, common stand by pump of horizontal centrifugal end suction backpull out type with gland packing and capable to deliver. The pump shall be coupled to S1 DUTY TEFC IE3 motor of suitable HP with speed of 2950 RPM and complete set shall be mounted on common base frame for pump and motor from M.S. Channel of required size with epoxy coated edging complete with Antivibration pads with bolt & nuts for the pumps to be considered. (Common Pump for Hydrant & Sprinkler system)
The pump shall be capable of giving a discharge of not less than 150 per cent of the rated discharge, at a head of not less than 65 per cent of the rated head. The shut off head shall be within 120 per cent of the rated head.
The motor shall be squirrel cage A.C. induction type suitable for operation on 415 volts 3 phase 50 Hz. system. The motor shall be totally enclosed fan cooled type conforming to protection clause IP 55 & Class F insulation. The synchronous speed shall be 2950 RPM as specified. The motor shall be rated for continuous duty and shall have a horse power rating necessary to drive the pump at 150 per cent of its rated discharge with at least 65 percent rated head. The motor shall conform to I.S.325-1978.
Arrangement of Gland leak drain to nearest drain point shall also be considered along with necessary accessories
NOTE: Pumps shall be factory assembled and factory tested with all test certificate to be submitted before dispatch, 3rd party performance inspection to be done at factory.
Flow : 2280 LPM
Head : 77 mts
Supply, installation, testing & commissioning (SITC) of Diesel Engine Driven common stand by pump, common stand by pump of horizontal centrifugal end suction backpull out type with gland packing and capable to deliver.Also the pump shall be capable of giving a discharge of not less than 150 per cent of the rated discharge, at a head of not less than 65 per cent of the rated head. The shut off head shall be within 120 per cent of the rated head. Complete set shall be mounted on common base frame for pump and motor from M.S. Channel of required size with epoxy coated edging complete with Antivibration pads with bolt & nuts for the pumps to be considered. (Standby pump, common for Hydrant & Sprinkler system)
Pump shall be with automatic / manual starting mechanism and other accessories with fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity for 6 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), gauge glass, fuel piping with necessary valves, 2 Nos. x 12 volt battery, & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required.
The pump shall be coupled to suitable HP of Diesel engine radiator water cooled type with speed ranging from 1800 to 2300 RPM.
Arrangement of Gland leak drain to nearest drain point shall also be considered along with necessary accessories
NOTE: Pumps shall be factory assembled and factory tested with all test certificate to be submitted before dispatch, 3rd party performance inspection to be done at factory, 3rd party performance inspection to be done at factory.
Flow : 2280 LPM
Head : 70mts
Supply, installation, testing & commissioning of Electrical motor driven Vertical Inline Jockey pump with mechanical seal and capable to deliver.The pump shall be coupled to S1 DUTY TEFC IE3 motor of suitableHPwith speed of 2900 RPM and complete set shall be mounted on common base frame for pump and motor from M.S. Channel of required size with epoxy coated edging complete with Antivibration pads with bolt & nuts for the pumps to be considered. (Common Pump for Hydrant & Sprinkler system)
Arrangement of Gland leak drain to nearest drain point shall also be considered along with necessary accessories
NOTE: Pumps shall be factory assembled and factory tested with all test certificate to be submitted before dispatch, 3rd party performance inspection to be done at factory.
Flow : 180LPM
Head : 70mts
Control Panel for Fire pumps. (CPRI Approved) IP55
Fabricating & Supply, installing, testing and commissioning of compartmentalised common control panel with Electrical Interlocking system, necessary hooters on top of it for Electrical motor driven pumps and Diesel engine driven pumps.
INCOMING (TOP ENTRY ONLY)
1 no. 160A 4 POLE MCCB
1 Set of 160 Amps. 4 POLE Al. Bus bars with colour coded heat shrinkable PVC sleeves.
1 Set of RYB indicating lamps with 6A MCB
OUTGOING
Feeder for main pumps - 2 Nos.
1 No. 125A TPN MCCB
Soft starter, comprising the following (Commom Pump for Sprinkler &Hydrant System ) with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons.
When main pumps/Diesel Pump are on, respective Jockey pumps should be automatically turned off
Jockey pump should be automatically turned off when respective main pumps/Diesel Engine are on
Feeder for Jockey pumps - 2 Nos.
1 Nos. 32A TPN MCCB
Soft starter, with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons.
DIESEL ENGINE MAIN PUMP 1 No.
a) 20Amps DPMCB - 1 No.
c) 1 set of indicating lamps for the following :
1. phase indication
2. battery charger on
3. over load relay
4. DC supply on
5. control switch on
6. Engine fails to start
7. Pump on
8. Low oil pressure
9. High water temperature
d) 1 sets of push button stations for the following :
1. Engine Start
2. Engine Stop
3. Engine - hooter ACK
4. Engine - fault reset
f) Auxilary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set.
g) Hooter for audio alarm (Industrial type) - 1 No.
All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffners ( if required). The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.
Also panel shall have sufficient (min. 1Nos incoming & 3Nos Outgoing per pumpset) NO/NC contacts for extending the status of fire pumps to the Fire alarm panel / BMS. Panel Vendor shall include factory inspection & the provision of accommodating holes for Panel suppression system for the panel for future integration of the same. Panel vendor should be CPRI approved with latest renewal (if any) and panel shall be IP 55, it shall consist of relaying the status of pumps, incoming feeders to Fire Alarm Control Panel/BMS through the necessary module placed near the Fire MCC panel by Fire Alarm Vendor
1100 V GRADE POWER / CONTROL CABLES
Supplying, laying, testing & commissioning of Fire Survival, PVC outer sheath, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc. The cables shall be laid in tray / Hume pipe / in trenches/on walls/ floor etc. as required. The minimum size of the cables is mentioned below:
3.C x 70 sq.mm for main pumps (Al)
3 C x 6 Sqmm. Jockey pumps / Booster Pumps (CU)
12 C x 2.5 Sqmm. Diesel engines (CU)
2 C x 2.5 Sqmm. for Instrumentation (CU)
CABLE TRAY
Supplying and fixing of perforated G.I.sheet cable tray with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 50mm X 500mm, 2mm thick Size of the tray shall be suitable for laying the above mentioned cables.
50mm x 100mm, 2mm thick (Diesel engine & Jockey pump)
50mm x 150mm, 2mm thick (Electrical main pump)
50mm x 300mm, 2mm thick (Panel)
50mm x150mm, 2mm thick (Above fire pumps)
Supplying and fixing of G.I. Earthing strips of 25mm X 6mm thick, strip shall be run on floor / ceiling / walls, from the equipment to the nearest Earth pit with necessary accessories as required. ( Earth pit shall be executed by other agencies).
Note: The suction headers to have end flange with dummy flange as per BS-10 standards: Table - E
250mm nominal dia 6.35mm thick
200mm nominal dia 6.35mm thick
150mm nominal dia
100mm nominal dia
80mm nominal dia
50mm nominal dia
25mm nominal dia
Supply, Erection, Testing and commissioning of C.I. Gate valves with Limit switch as per IS:5312 (PN 16 Rating, for suction side of the pumps) and rising spindle type with necessary adapter flanges, bolts, nuts, washers, gaskets etc.
250mm nominal dia
200mm nominal dia
100mm nominal dia
80mm nominal dia
Supplying, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh,suitable adapter flanges, nuts, bolts, gaskets etc. complete. (suction side) PN16 Rating
200mm dia.
100mm dia.
Supplying, installing, testing and commissioning of CI Non-return valves (PN 20) Ball type with required adapter flanges, nuts, bolts and gaskets etc. complete.
150 mm nominal dia
80 mm nominal dia
Supplying, Installing, testing and commissioning C.I butterfly valves with Limit switch, SG IRON DISC & STEM, as per BS 5155 (PN-16) slim seal standard lever operated type. Above 150mm shall be gear operated, with required flanges, nuts, bolts etc. complete. Location: Hydrant & Sprinkler Riser Tappping
150mm nominal dia
Supplying, installing, testing and commissioning of Brass Ball valves (PN20) with fittings of screwed end type.
25 mm dia ( For drain)
50 mm dia ( For manifold )
Supply, Installation of Flow metre (Electronic type) on Test line to measure 150 % of pump flow and suitable to 150 mm dia. (PN20) with fittings of screwed end type.
Supply and installation of Differential pressure switch (5Nos) of suitable range of (03 to 15 bar pressure B-series ) for pumpsets with Ball valves, Fittings like unions / colors / reducers etc.
Supply and installation of Pressure gauges of suitable range (03 to 15 bar pressure) for pumpsets with Ball valves, siphon, Fittings like unions / colors / reducers etc. Glycol filled Pressure gauge with dial 150mm
Supply, Installation, Testing & Commissioning of double flanged Air cushion tank(ACT)/ pressure vessel of 450mm dia fabricated from 10mm M.S. plate with dished ends from 10mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with approved quality of pressure switches, pressure gauge and all other required accessories to operate Main fire pump, Sprinkler pump and Jockey pump at drop of pressure, automatically at required pressure setting (pressure sketch to be issued separately). With valves to operate as per operating sequences including drain valve, air release valve with stop cock on the top, inlet with isolating valve duly painted from inside and outside complete as required. Height of the ACT should be considered above Delivery header
SITC of Exhaust pipe for Diesel engine of 150 mm dia M.S. Medium grade with mineral wool insulation, 12mm or 48kg/cum and 22 gauge aluminum sheet cladding including fittings, fixings & brackets. Necessary Silencer shall be included in to mitigate the noise, 150mm dia M.S. Medium Grade shall be laid above ground with structural steel supports & SITC of bird mesh at the terminating/exhaust side of the pipe
EXTERNAL HYDRANT SYSTEM
150 mm dia
80 mm dia
Supplying, installing, testing and commissioning of M.S. (Class C) Below Ground Pipes confirming to IS 3589, Heavy grade with suitable type of supports, malleable specials such as Reducers,Tees, elbows, (Socket Weld fitting up to 50mm dia) flanges. Including cutting, Welding as per drawings. The rate quoted should be included with anticorrosive treatment with 4 mm thick polymer corrosion resistant tape as per IS 10221, overlap shall be 15mm minimum.The pipe shall not be less than 1.0 m below ground level at any point. The application process shall be strictly according to manufacturer’s specification.
150 mm dia
Supply, Installation, Testing & Commissioning of Single headed SS 304 hydrant valve as per IS: 5290 (Type A). The valves should be complete with hand wheels, quick coupling connections, springs and blank caps.
Supply and installation of controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia and 15 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested for flame resistance test in accordance to IS:8423. Hose shall be complete with ISI marked SS(304) male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire (Location : External fire hydrant)
Supply and installation of 63 mm dia instantaneous pattern ISI mark SS (304) branch short pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supply and installation of weather proof lockable cabinet of size not less than 0.75 x 0.60 x 0.25 mtr made out of SS304 sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade.
Supplying, Installing, testing and commissioning C.I butterfly valves, SG IRON DISC & STEM, as per BS 5155 (PN-16) slim seal standard lever operated type. Above 150mm shall be gear operated, with required flanges, nuts, bolts etc. complete. Location : Entry & Exit Gate Crossing
150mm nominal dia
Supply, Installation, Testing & Commissioning of NP2 Class Hume Pipe for road crossing
WET RISER SYSTEM
Also rates including flushing and chemical cleaning of pipes.
150 mm dia
80 mm dia
Supply, Installation, Testing & Commissioning of Single headed SS 304 hydrant valve as per IS: 5290 (Type A). The valves should be complete with hand wheels, quick coupling connections, springs and blank caps.
Supplying & fixing non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) type-B of 63 mm dia and 15m length as described below. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS(304) male & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire (Location : Internal fire hydrant).Cost Shall be iclusive of M.S. Channel &Angles.
Supplying and fixing 63 mm dia instantaneous pattern ISI mark SS(304) branch short pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supply, Installation, Testing & Commissioning of swinging type First Aid hose reel in red color drum with 36 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia gate valve stop cock, (IS:778, class - II) terminating with G.M. coupling & nozzle of 6mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastener, bolts & nuts conforming to IS:884-1985 (Reaffirmed 2000) complete as required.
Supplying and fixing standard fireman's axe with heavy rubber handle and Axe holder.Cost Shall be iclusive of M.S. Channel &Angles.
Supply and installation of Pressure gauges of suitable range (3 to 15 bar pressure) for pumpsets with necessary fittings, dapter flanged ends, Ball valves, siphon, Fittings like unions / colors / reducers etc. Glycerine filled Pressure gauge with dial 150mm
Supplying, installing, testing and commissioning of CI Non-return valves (PN 20) Ball type with required adapter flanges, nuts, bolts and gaskets etc. complete.
150 mm nominal dia
Supplying and fixing approved make 20mm dia. of Forged Brass automatic air release valve with Forged Brass Ball valve, union etc. with necessary fittings, adapter flanges, complete set.
Supply & Installation of pre-cast P.C.C for pipe supports & MS Supports on the terrace complete inclusive of necessary accessories to complete.
Note: Vendor shall get approval from consultant/client prior to fabrication.
SPRINKLER SYSTEM
Also rates including flushing and chemical cleaning of pipes.
150mm dia
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
Supply, Installation, Testing & Commissioning of Standard response Upright Type Sprinklers with 68 Deg.C.Temp. rating K80 sprinkler
Supply, Installation, Testing & Commissioning of Standard response Pendent Type Sprinklers of 68 Deg.C.Temp. rating K80 sprinkler
Supply, Installation, Testing & Commissioning of standard response Sidewall Sprinklers of 68 Deg.C.Temp. rating K80 sprinkler
Supply and Installation of approved type rosette plates (Recessed type, in two piece) for Sprinklers below false ceiling area.
The Rosette shall be fabricated by S.S. 304 of 2mm thick and the finish shall be powder coated and color shall be as approved by architects / clients.
Supply, Installation, Testing & Commissioning of UL/FM approved 1.5m corrugated SS-304 /braided flexible sprinkler pipe droplet for 12 kg/ sq. cm. working pressure Flexible Drop to all ceiling mounted sprinkler heads.
Supply, Installation, Tesing & Commissioning of electrically operated water flow switches (Vane type) including tamper switch and accessories, complete with tap off socket arrangement as required, with potential free contact with 2 Nos. NO/NC.
100mm dia
Supply, installation, testing and commissioning of butterfly valve PN-16 with Tamper switch of CI body SG iron rilson coated disc , Working pressure not less than 16 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.( LEVER TYPE)The tamper switch shall be provided with potential free contact with 2 nos. NO/NC.
100mm dia
Supply, installation, testing and commissioning of inspectors test assembly complete with test valve PN 16 Rating, with all necessary accessories.
50mm dia
Providing & fixing dial type (150 mm) pressure gauge with isolation forged brass ball valve suitable for working pressure of 250PSI. Cost shall be inclusive of fittings etc as required.
Supplying, installing, testing and commissioning of hydraulically operated 150mm dia Sprinkler control valve, with water motor gong bell and trims as required, with butterfly valve on upstream and downstream, necessary pressure gauges, drain valves, ball valves, check valves, strainers etc. Necessary adapter flanges, fittings, complete shall be considered. Alarm valve shall be UL / FM Listed
CO2 FLOODING SYSTEM FOR MAIN ELECTRICAL & MAIN LT PANEL ROOM
Supplying, installing, testing and commissioning of Cylinder with Valve assembly 68 Litres water capacity CO2 Cylinder with 45 Kgs of Gas, Master Valve and 24 VDC Solenoid for Auto and Manual Operation and required accessories
Type : High Pressure Seamless Brand New Rechargeable type CO2 Cylinder.
Water Capacity :68 Ltrs; 3. CO2 Capacity : 45 Kg; 4. Standard : IS-7285
Test Pressure : 250 Kg/cm2; 5. Working Pressure : 150 Kg/cm2
Make : ROTAREX (CEODEUX ); 9. Max. Working Pressure : 250 Kg/ Cm2
Supplying, installing, testing and commissioning of Cylinder with Valve assembly 68 litres water capacity CO2 Cylinder with ISI marked and CCE Approval to fill 45 Kg CO2 gas and required accessories
Type : High Pressure Seamless Brand New Rechargeable type CO2 Cylinder.
Water Capacity :68 Ltrs; 3. CO2 Capacity : 45 Kg; 4. Standard : IS-7285
Test Pressure : 250 Kg/cm2; 5. Working Pressure : 150 Kg/cm2
Approval : BIS & CCOE; 7. Cylinder Make : EKC
Make : VTI / KEW/ Equivalent ; 9. Max. Working Pressure : 250 Kg/ Cm2
Supplying, installing, testing and commissioning of Cylinder with Valve assembly CO2 Cylinder Bank Accessories (Suitable for 45Kg Capacity CO2 Cylinders) and required accessories
1 Manifold a. Material : Seamless Sch.80 pipe as per
ASTM-A-106 Gr.B b. Finishing : finishing with P.O Red shade
Frame Assemble
Holding Rod & Nut is provided for cylinders c. Finishing
Powder Coating finishing d. Grouting :
Suitable Holes Provided for Anchor Fastener
Gas Weight Monitor Fixing Rail Assembly
Material : Finishing : Powder Coating finishing with RED shade
Supplying, installing, testing and commissioning of Continuous Gas Weight loss Monitor with required accessories.Make - UFC
Supplying, installing, testing and commissioning of Online Cylinder Weight Monitoring Panel with required accessories.
Supplying, installing, testing and commissioning of Co2 Discharge Nozzle with required accessories. Make - UFC
Supplying, installing, testing and commissioning of NRV for C02 cylinders with required accessories. Make - UFC
Supplying, installing, testing and commissioning of 1/2" H.P.Hose from cylinder manifold with required accessories.
Supplying, installing, testing and commissioning of 1/4" H.P. Hose from valve to pneumatic head with required accessories.
Supplying, installing, testing and commissioning of Master adaptor for cylinder with required accessories.
Supplying, installing, testing and commissioning of conventional smoke/heat detector with required accessories.
Supplying, installing, testing and commissioning of Gas Release Panel with standby battery with required accessories.
Supplying, installing, testing and commissioning of Manual Gas Abort unit with required accessories.
Supplying, installing, testing and commissioning of Manual Gas Release unit -WP with required accessories.
Supplying, installing, testing and commissioning of Co2 Discharge Pressure Switch with required accessories.
Supplying, installing, testing and commissioning of Manifold safety outlet with required accessories.
Supplying, installing, testing and commissioning of Sounder cum Flasher with required accessories.
Supplying, installing, testing and commissioning of Sounder cum Flasher with required accessories.
Supplying, installing, testing and commissioning of Schedule 40 seamless pipe along with elbows, tees, reducer etc with required accessories.
Supplying, installing, testing and commissioning of 2 x 1.5 sq mm cu conductor cable with glands with required accessories.
PANEL TUBE BASED SUPPRESSION SYSTEM
Supply of 2kg Clean Agent (FK-5-1-12) cylinder with DLP valve, cylinder mounting bracket,1/4-6 Male connector with spring top end of line adaptor with pressure guage,pressure switch and Master control panel with all required accessories. Location :Main Electrical Panel
Supplying, installing, testing and commissioning of Fire Detection tube (CE Approved ) etc with required accessories.
FK-5-1-12 CLEAN AGENT FIRE EXTINGUISHING SYSTEM FOR FIRE COMMAND CENTRE
Supplying, installing, testing and commissioning of Cylinder - Valve assembly with 80Ltr cylinder /valve assembly with pessure Gauge and filled with FK-5-1-12 gas. Cost Shall be Inclusive of Filling Agent.
Supplying, installing, testing and commissioning of Valve Actuators and Accessories for Master cylinder following comprising of ;
Solenoid actuator assembly 24V DC
Manual Actuator
Actuation hose
1.5"Discharge Hose Flexible
Elbow
1/4 NPT X 1/4 BSPP M Adaptor
Discharge Nozzles
Pressure Switch
Cyilnder Strap
warning signages to indicate during the fire
Supply,Installation, Testing & Commissioning of Fire Detection system for to integrate with FK-5-1-12 system follwing comprising of;
2Zone conventional Panel with Gas Release switch with Battery.( Non UL listed)
Conventional Multi Detector( Non UL listed)
Manual abort switch ( Non UL listed)
Manual release switch ( Non UL listed)
Horn Strobe ( Non UL listed)
Supply, wiring, testing and commissioning of ISI Certified 2Cx1.5 sq.mm, twisted shield, FRLS type, armored double insulated copper cable with Ferrules, Lugs, saddles, saddles base & other accessories complete as required.
FIRE EXTINGUISHERS
Supply, installation, testing and commissioning of following types of extinguisher of halogen free with provision of wall bracket (fixed with anchor fastener)
Supply, Installation, Testing & Commissioning of ABC Stored Pressure type Fire Extinguisher 4kg with necessary accessories etc.
Supply, Installation, Testing & Commissioning of CO2 type Fire Extinguisher 9kg with necessary accessories etc. Location :Main Electrical room
Supply, Installation, Testing & Commissioning of CO2 type Fire Extinguisher 4.5 kg with necessary accessories etc.
Supply, Installation, Testing & Commissioning of clean agent fire extinguisher of 4kg.capacity with necessary accessories etc.
Supply, Installation, Testing & Commissioning of AFF Mechanical Foam type capacity of 9 lit fire extinguisher.
Locations: Fire Pump room & DG Area
Supply & Installation of fire bucket (fabricated from 20SWG MS sheet) with lid and filled with river sand complete including painting with white colour inside & Red out side and Letter "FIRE" in black out side as approved by Engineer-in Charge with all contractors material, labour, transportation, lead & lift etc. complete including cost of incidental charges for successful completion of work as per specifications and as directed by Engineer-in-charge at site.
FIRE SIGNAGES
The following descriptive photoluminescent Green or Red color safety signages in different sizes / graphics /colours / texts can be made according to the standards accepted by the local Fire service department.The intensity of glow in dark should last not less than 2 hours and the strongest glow shall be produced in the first 30 minutes
RUNNING MAN ARROW DOUBLE SIDE (150X400mm)
EXIT (400x150mm)
FIRE EXIT (400x150mm)
INCASE OF FIRE DONT USE LIFT,USE STAIRCASE (250x300mm)
FIRE HYDRANT & HOSE REEL(150x200mm)
MANUAL CALL POINT (150X400mm)
FIRE EXTINGUISHER (150x400mm)
Supply & Installation of EVACUATION MAP color which needs to be displayed onto a GLASS frame which are Self Glow type. Size should be A2 Size 17" x 22". (samples to be shown before execution) Placed Inside the FCC Room & Each Floor.
Supply & Installation of" Fire Pump Details & Operation Sequence"t should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3' * 4'
Supply & Installation, in position the signages "FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3' * 4'
Type -I comprising the following
A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.
B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POINTS.
C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.
E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUTION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
Type - II comprising the following
ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.
A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM.
B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: 101, xxxxxxxxxxxxxxxxxxxx
C) REFER EVACUTION PLAN FROM EVACUATING STANDARD PEOPLE.
D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE
E) IN CASE OF THE CASUALITIES, CALL AMBULANCE BY DIALLING NUMBER…………….
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
FIRE ALARM PANEL
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent Analog Addressable Type 8 Loops Fire Alarm Control Panel with with auto dailer with 160 character LCD display, four access level. 1000 event historic logging, flash EPROM sufficient numbers of programmable relay control, 240V DC standby & Battery backup/battery charger minimum of 24 hrs (please provide battery calculations), auto dialer, built in or external continuous on line printer.. The FACP shall have provision of loop expansion, The FACP shall be networkable type. The FACP shall also house inbuilt 120W mixed amplifier for firemen communication system. The FACP loops is designed considering 125 detectors & devices per loop and each loop is loaded 80%. FA Panel should have provision of RS 485 MODBUS/Bacnet protocal for BMS integration
REPEATER PANEL
Supply, Installation, Testing & Commissioning of remote annunciators with 4 line 80 character LCD display. The annunciator shall have built in memory to record the alarm events and shall have standard buttons for alarm ack, reset etc. Max of 32 remote annunciators shall be loopable to one FACP.
DETECTORS
Photo Detectors: Supply, Installation, Testing and Commissioning of Intelligent Addressable Photo Electric Type Smoke Detectors Above False Ceiling with indicating lamp, mounting base and all other mounting accessories complete as required.
Photo Detectors: Supply, Installation, Testing and Commissioning of Intelligent Addressable Photo Electric Type Smoke Detectors - Below False Ceiling with indicating lamp, mounting base and all other mounting accessories complete as required.
Photo Detectors: Supply, Installation, Testing and Commissioning of Intelligent Addressable Photo Electric Type Smoke Detectors - Below False Flooring with indicating lamp, mounting base and all other mounting accessories complete as required.
Heat Detector (Addressable): Supply, Installation, Testing and Commissioning of Intelligent Addressable Heat Detectors with indicating lamp, mounting base and all other mounting accessories complete as required.
Multi Sensor Detector: Supply, Installation, Testing and Commissioning of Intelligent Addressable Multi Sensor Detectors with indicating lamp, mounting base and all other mounting accessories complete as required.
Response Indicator: Supply, Installation, testing and commissioning of Response Indicator with all mounting accessories complete as required.
DEVICES
Isolator Module: Supply, Installation, testing and commissioning of Isolator Module with indicating lamp, mounting base and all other mounting accessories complete as required.
Manual Call Points: Supply, Installation, testing and commissioning of Intelligent Addressable Manual Call Points with indicating lamp, mounting base and all other mounting accessories complete as required.
Control Module for Hooter: Supply, Installation, testing and commissioning of Addressable Control Modules for activating hooters with all the mounting accessories complete as required. One CM shall provide one activation signals.
Control Module for Fire Damper: Supply, Installation, testing and commissioning of Addressable Control Modules for activating hooters with all the mounting accessories complete as required. One CM shall provide one activation signals.
Control Module for Access Controllers System Integration: Supply, Installation, testing and commissioning of Addressable Control Modules for overriding access door command with all the mounting accessories complete as required.
Control Module for Base builder FA Panel Integration: Supply, Installation, testing and commissioning of Addressable Control Modules for Base builder FA Integration with all the mounting accessories complete as required. (Base builder Need to add One no. of Monitor Module for Integration)
Control Module for PA Integration: Supply, Installation, testing and commissioning of Addressable Control Modules for overriding PA system with all the mounting accessories complete as required. One CM shall provide one activation signals.
Relay Module for High Voltage Applications: Supply, Installation, testing and commissioning of Addressable Relay Modules for Tripping the AHU's Equipments with all the mounting accessories complete as required.
Monitor Module: Supply, Installation, testing and commissioning of Addressable Monitor Modules for Interfacing PFC/Dry Inputs of Fire Pump Signals, Sprinkler Line Flow Switch Status, Base builder fire alarm panel integration with all the mounting accessories complete as required.
Panic Bars
Supply, Installation, Testing & Commissioning of Panic Bars. The panic bar shall have Lock, local hooter, and potential free contacts for integration with FAS or BMS
NOTIFICATION DEVICES
Hooters: Supply, Installation, testing and commissioning of ceiling type Hooters with all mounting accessories complete as required.
Hooters with Strobes: Supply, Installation, testing and commissioning of Hooters with Strobes with all mounting accessories complete as required.
CABLES, CONDUITS:
Supply, wiring, testing and commissioning of ISI Certified 2Cx1.5 sq.mm, twisted shield, FRLS type, armored double insulated copper cable with Ferrules, Lugs, saddles, saddles base & other accessories complete as required. The cable specification shall meet FACP & detectors manufacturer requirement. (Including hooter cabling)
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PA Rack
Supply, Installation, Testing & Commissioning of sheet metal 15U rack (or vendor shall calculate and propose suitable rack) for mounting of PAS Controller & Amplifier as per the technical specification with all mounting accessories etc
System Controller
Booster Amplifiers
Supply, Installation, Testing & Commissioning of Booster Amplifier for PA system with RMS output (actual) 480 W with all mounting accessories etc.
Supply, Installation, Testing & Commissioning of Booster Amplifier for PA system with RMS output (actual) 240 W with all mounting accessories etc.
Speakers
Ceiling Mount Type Without Mounting Box : Supply, Installation, Testing & Commissioning of Ceiling mount type Round Speakers of 6 Watts Rated Power with Dual Cone High Sensitivity Loudspeaker Drivers, Opening Angle of 180o and builtin 100 Volts Matching Transformer. The Speaker Cabinet shall be White Color with mounting base and all other mounting accessories complete as required.
Mounting Box for Ceiling speaker : Supply, Installation, Testing & Commissioning of mounting box for Round Speakers of 6 Watts Rated Power with Dual Cone High Sensitivity Loudspeaker Drivers, Opening Angle of 180o and builtin 100 Volts Matching Transformer. The Speaker Cabinet shall be White Color with mounting base and all other mounting accessories complete as required.
BOX Speaker: Supply,installation & commissioning of 6 W rated Horn Speakers with wall mounting brackets other required mounting accessories
Cable & Conduit
Supply, Laying, Terminating, Testing & Commissioning of 2 core 24/0.2 mm ATC twin twisted, FRLS type Unarmored Cable as per the technical specification with all mounting accessories etc
Supply & Laying of FRLS Conduit of 3/4” dia & 2mm thickness with accessories like saddles, saddle base etc complete as required as per the technical specification with all mounting accessories etc
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supply, Installation,Testing Commissioning of IP Based CCTV System comprising of following:
Supply, Installation, Testing & Commissioning of Indoor 1/3" CCD Dome colour camera ensure HD 1080P resolution, 5 Mega pixel ,IR Camera(Day/Night) 2.8mm to 12mm varifocal lens with mounting accessories -IP based
Supply, Installation, Testing & Commissioning of IP Varifocal bullet POE Camera, 5MP, support 1080p,1/3" Progressive CMOS, ICR with IR, , The bullet camera shall install indoor / outdoor areas. Power supply to be taken from Ethernet cable. Camera should be above to cover a distance of (30 / 50) Mtrs minimum.
Multilens(3.6mm) camera with IR for 360° coverage,1/3'' 4MP PS CMOS Image sensor,Camera should be above to cover a distance of 30 Mtrs minimum,WDR (120dB), Day/Night (ICR), 3D NR, ROI, AWB, AGC, BLC, HLC.
MONITOR
Supply, Installation, Testing & Commissioning of 42'' LCD Monitors complete with wall mount kit
Supply, Installation, Testing and Commissioning of15U Wall mounted Rack.
CABLE & CONDUIT
Supply, Installation, Testing & Commissioning of 24 port layer 2 switch with 10/100/1000 POE Manage Switches with IP multicast snooping and data-driven IGMP support and with two 1000baseT single mode FO uplink ports and all related termination accessories as per site specific System requirement.
Supply Laying, Terminating & Testing of Unarmoured Cat-6 cable, laid on Surface with required terminations as required with Cable tie`s & Tags.
Supply & Laying of FRLS Conduit of 3/4” dia & 2mm thickness with accessories like saddles, saddle base etc complete as required as per the technical specification with all mounting accessories etc
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
HT PANEL
RING MAIN GEAR
Supply of 11KV, 25 KA, 630A, Outdoor type Ring Main Gear (RMG) as per the specification and annexure
11KV 25KA 630Amps HT RING MAIN GEAR comprising of Two Incoming Air Break Load Break Switches and One Outgoing HT Vacuum Circuit Breaker for OUTDOOR Installation
The specification of the Panel should be approved by TNEB
HT PANEL - POINT OF SUPPLY
Supply of 630A 11kV HT VCB Panel for OUTDOOR Installation
11KV, 25 KA, 630A, OUTDOOR SINGLE PANEL VACCUM
CIRCUIT BREAKER complete as per Specification
Sub total
Total
Provision to receive Incoming/Outgoing cable excluding cable glands and cable termination Kit etc.,
HT PANEL SPECIFICATION
Vaccum Circuit Breaker
11KV, 630A, 25KA Horizontal Draw out/isolation VCB fitted with Manual/Motor operated spring charging mechanism with 230V AC motor and motor control switch, shunt trip coil of 110V DC, closing coil of 110V DC, Auxiliary Contact 4NO+4NC, Mechanical ON/OFF indicator, mechanical operation counter, Anti pumping feature, Automatic safety shutters and Push button
Load Break Swith
11kV 630A, 25kA, Load break switch with Earth switch, with 2NO+2NC Aux. Contact, Spring charged mechanism Manually operated
Potential Transformer
Three Phase, Resin Cast, Dry type, Draw out PT with HT/LT fuses of ratio (11KV/1.732)/(110V/1.732), Core 1:Cl. 0.2 50VA
Current Transformer
Single phase, Resin Cast, Dry Type Current Transformer of suitable ratio/5-5A, Core 1: Cl. 0.5 / 15VA for metering, Core 2: Cl. 5P10 / 15VA for protection
Meters
Provision for digital Trivector Meter L & T (or) Secure Make
Protection Relays
Numerical type Triple-pole Non-Directional, IDMT, 2O/C + 1E/F with High set with 1.3 Sec M140A
Auxiliary Relays
Master trip Relay-MVAJH 13
Indication Lamps
VCB On/OFF/Auto Trip/Spring Charge/Trip Circuit Healthy Indication Lamps
R,Y,B Phase Indication Lamps
Control Switches
Breaker Control Switch (Close-Neutral-Trip)
Test Terminal Block-Nelster Make/Reputed
Bus Bars
Main Bus: 630Amps Copper Bus bar with PVC Sleeve insulation
Common for Switch gears
Control wiring with 2.5sqmm wire in appropriate colour
Heater ON/OFF switch with filament type 80W space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp, Door limit switch, MCBs / Fuses for AC / DC Control
Auxiliary DC Power Source – 230V AC to 110V DC
Enclosure
MS Sheet steel suitable for Outdoor Installation Powder Coated with Siemens Grey Paint finish
Termination
Incoming (Excluding cable termination kits, lugs and glands)
Outgoing (Excluding cable termination kits, lugs and glands)
Others
Mechanical ON/OFF Indication
Manual Trip Push Button
Panel Mounting Surge Arrester-9KV,10KA
SINGLE HT PANEL - POINT OF SUPPLY
Vaccum Circuit Breaker
Horizontal Draw Out VCB fitted with Manual / Motor Operated mechanism with 230V AC Motor & Motor Control Switch, Mechanical ON / OFFspring charging, indicator Operation Counter, Automatic safety shutters & push button,
Shunt trip Coil
Closing Coil
Spare auxiliary contact
Anti pumping Feature
Power Pack
Potential Transformer
Three Phase, Resin Cast, Dry type, Draw out PT with HT/LT fuses of ratio (11KV/1.732)/(110V/1.732), Core 1:
Current Transformer
Single phase, Resin Cast, Dry Type Current Transformer of suitable ratio/5-5A, Core 1: Cl. 0.5 / 15VA for metering, Core 2: Cl. 5P10 / 15VA for protection
Meters
Provision for digital Multi Function Meter
Protection Relays
Numeric Non directional IDMT combined 3O/C+1 E/F relay with high set
High speed /Master trip relay
Indication Lamps
VCB On/OFF/Auto Trip/Spring Charge/Trip Circuit Healthy Indication Lamps
R,Y,B Phase Indication Lamps
Control Switches
Breaker Control Switch (Close-Neutral-Trip)
Flush Head type Trip Circuit Healthy Push Button
Bus Bars
Main Bus: 630Amps Copper Bus bar with PVC Sleeve insulation
Common for Switch gears
Control wiring with 2.5sqmm wire in appropriate colour
Heater ON/OFF switch with filament type 80W space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp, Door limit switch, MCBs / Fuses for AC / DC Control
Auxiliary DC Power Source – 230V AC to 110V DC
Enclosure
MS Sheet steel suitable for Outdoor Installation Powder Coated with Siemens Grey Paint finish
Termination
Incoming (Excluding cable termination kits, lugs and glands)
Outgoing (Excluding cable termination kits, lugs and glands)
Panel Mounting Surge Arrester-9KV,10KA
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
250kVA Outdoor Type Unitized Substation
Supply erection testing and commissioning of 250kVA outdoor type Unitized substation with following specification
11KV 25KA 630Amps HT VCB -1No. As HT incomer specification
250kVA Dry type transformer with OLTC -1No. As transformer specification - Copper Busbar
630A, 4P, MDO Indoor type 50KA, Microprocessor based MCCB inbuilt overload, short circuit and earth fault release with CT including Interconnecting with Multifunction meter and indicating lamps -1No. Bus bar Copper
The specification of the Panel should be approved by TNEB
Provision to receive Incoming/Outgoing cable excluding cable glands and cable termination Kit etc.,
SINGLE HT PANEL - TRANSFORMER PROTECTION
Vaccum Circuit Breaker
630A, 350MVA. Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 110V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Button, and mechanical Operating Counter
Shunt trip Coil
Closing Coil
Spare auxiliary contact
Anti pumping Feature
Power Pack
Potential Transformer
Three Phase, Resin Cast, Dry type, Draw out PT with HT/LT fuses of ratio (11KV/1.732)/(110V/1.732), Core 1:
Current Transformer
Single phase, Resin Cast, Dry Type Current Transformer of suitable ratio/5-5A, Core 1: Cl. 0.5 / 15VA for metering, Core 2: Cl. 5P10 / 15VA for protection
Meters
Provision for digital Multi Function Meter
Protection Relays
Numeric Non directional IDMT combined 3O/C+1 E/F relay with high set
High speed /Master trip relay
Transformer fault annunciator on type auxiliary relay
Auxiliary Relay for OLTC
Indication Lamps
VCB On/OFF/Auto Trip/Spring Charge/Trip Circuit Healthy Indication Lamps
R,Y,B Phase Indication Lamps
Control Switches
Breaker Control Switch (Close-Neutral-Trip)
Flush Head type Trip Circuit Healthy Push Button
Annunciator- 8 Window
Buzzer
Bus Bars
Main Bus: 630Amps Copper Bus bar with PVC Sleeve insulation
Common for Switch gears
Control wiring with 2.5sqmm wire in appropriate colour
Heater ON/OFF switch with filament type 80W space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp, Door limit switch, MCBs / Fuses for AC / DC Control
Auxiliary DC Power Source – 230V AC to 110V DC
Enclosure
MS Sheet steel suitable for Indoor Installation Powder Coated with Siemens Grey Paint finish
Termination
Incoming (Excluding cable termination kits, lugs and glands)
Outgoing (Excluding cable termination kits, lugs and glands)
Panel Mounting Surge Arrester-9KV,10KA
250kVA Transformer Dry Type
250kVA Transformer
Supply of Transformer with following specification
11KV/433V INDOOR DRY TYPE CAST RESIN TRANSFORMER WITH OLTC/RTCC/AVR
Impedence : 5.5%/IS Tolerence
No Load Loss : 1.9kW
Load Loss : 8.5kW
Including Neutral CT and all other standard accessories complete set
Approved Makes:-
ESENNAR / CREL / KIRLOSKAR / VOLTAMP
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
01. Unloading, receiving at SITE, loading storing and leading shall be contractors account only.
02. Refer Schematic diagram and all panels should be as per the Schematic diagram only
LT PANELS CHECK LIST
Vendor should refer SLD for more details
Vendor should get GA drawing approval before fabrication
A Technical specification and make of materials should be get approved before the procurement of the materials
For Bus bars - 0.8A/Sqmm for Al & Earthing should be twin earthing
The withstanding capacity mentioned is Ics only
All MCCB should be with adjustable overload and fixed short circuit relays
All MCCB upto 250A should be with thermal magnetic release (O/C & S/C) and 250A & above should be with micro processer release (O/C & S/C)
All outgoing MCBs should be fixed inside the panel with view glass
All Incoming breakers should be 4P and outgoing breaker should be TPN
The Panel board construction should be 3B construction
All Incoming breakers should be with shunt trip facility for remote operation
All the meters should have RS 485 modbus output for BMS integration
Multi functionmeter should be with following parameters ; Volts, Amps, F, PF, W/VA, Wh /Vah ()
All Incoming & Outgoing breaker should be with ON/OFF/TRIP indication lamps as per SLD
All ACB should be with O/C, SC, E/F Release.
All Incoming breaker (ACB ) should have built-in RS 485 port.
All starter feeders (DOL & Star Delta Starter) should be considered as per Type-II Cordination Chart suitable for IE -2 motors
MV PANEL
Supply erection testing and commissioning of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 16 SWG MS sheet complete with bus bars, MV danger notice plate,Dual source multifunction meter protection relays, digital multi funtion meter/Load manager with RS 485, CTs interconnections with suitable capacity / solid Copper strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required.
Incomer .. 2No
630 Amps 35kA 4Pole MicroProcessor based MCCB
Metering CT : 630/5A, Cl:1.0 ,15VA - 3Nos for Metering
Machanicalinterlocking
Earth Fault Relay - 1 Set
Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set
Surge Protection Devcie - 1 Set
APFC Relay - 1 Set
Outgoing
i)400A 25kA TPN Micro Processor based MCCB - 3 Nos.
ii)125A 25kA TPN MCCB - 1 Nos.
01.The withstanding capacity mentioned is Ics only
02. All MCCB should be with adjustable overload and fixed short circuit relays
03. The Surge arrester should be class B/Type -1 for the protection of Lightning surge of 10/350µs wave form for EB Incomer.
04. 100% Neutral busbar
BUSBAR : Aluminium
RATING : 630 AMPS
POWER PANEL
Supply erection testing and commissioning of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 16 SWG MS sheet complete with bus bars, MV danger notice plate,Dual source multifunction meter protection relays, digital multi funtion meter/Load manager with RS 485, CTs interconnections with suitable capacity / solid Copper strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required.
EB Incomer .. 1No
400 Amps 35kA 4Pole microprocessor based MCCB
Metering CT : 400/5A, Cl:1.0 ,15VA - 3Nos for Metering
Earth Fault Relay - 1 Set
Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set
Surge Protection Devcie - 1 Set
APFC Relay - 1 Set
Outgoing
i)160A 25kA TPN based MCCB - 2 Nos.
ii)100A 25kA TPN based MCCB with Dual source Multi Function Meter with RS485 Port-7 Nos.
iii)100A 25kA TPN based MCCB - 2 Nos.
01.The withstanding capacity mentioned is Ics only
02. All MCCB should be with adjustable overload and fixed short circuit relays
03. The Surge arrester should be class B/Type -1 for the protection of Lightning surge of 10/350µs wave form for EB Incomer.
04. 100% Neutral busbar
BUSBAR : Aluminium
RATING : 415 AMPS
COMMON AREA PANEL
Supply erection testing and commissioning of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 16 SWG MS sheet complete with bus bars, MV danger notice plate,Dual source multifunction meter protection relays, digital multi funtion meter/Load manager with RS 485, CTs interconnections with suitable capacity / solid Copper strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required.
EB Incomer .. 1No
400 Amps 35kA 4Pole based MCCB
Metering CT : 400/5A, Cl:1.0 ,15VA - 3Nos for Metering
Earth Fault Relay - 1 Set
Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set
Surge Protection Devcie - 1 Set
APFC Relay - 1 Set
Outgoing
i)250A 25kA TPN based MCCB - 1 Nos.
i)63A 25kA TPN based MCCB - 7 Nos.
ii)40A 25kA TPN based MCCB - 4 Nos.
ii)32A 10kA DP MCB - 1 Nos.
01.The withstanding capacity mentioned is Ics only
02. All MCCB should be with adjustable overload and fixed short circuit relays
03. The Surge arrester should be class B/Type -1 for the protection of Lightning surge of 10/350µs wave form for EB Incomer.
04. 100% Neutral busbar
BUSBAR : Aluminium
RATING : 415 AMPS
70KVAR APFC Panel
Supply of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 14 SWG MS sheet complete with bus bars, MV danger notice plate, protection relays, digital multi funtion meter with RS 485, CTs interconnections with suitable capacity / solid aluminium strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required.
Incomer
160 Amps 4Pole 25kA MCCB-1No.
OUTGOING :
63 AMPS 10kA TPN MCB with 20KVAR Capacitor Duty Contactor: 2Nos.
40 AMPS 10kA TPN MCB with 10KVAR Capacitor Duty Contactor: 2Nos.
20 AMPS 10kA TPN MCB with 5KVAR Capacitor Duty Contactor: 2Nos.
01. All MCCBs shall have Adjustable Overload and Short Circuit setttings.
02. The withstanding capacity shall be Ics only.
An 6-Step APFC Relay with transducer shall be incorporated to maintain the power factor. The Panel shall also be made suitable to accommodate the following Capacitor Banks with all interconnections. Contactor switching should be with necessary protection fuse etc.,
20KVAR .. 2 Nos. 7% Detuned with harmonic filters
10KVAR .. 2 Nos. 7% Detuned with harmonic filters
5KVAR .. 2 Nos. 7% Detuned with harmonic filters
BUSBARS : ALUMINIUM
RATING : 160 AMPS
There shall be One Set of Metering Compartment incorporated with the following for Incomer:-
Metering CT : 160/5A, Cl:160,5VA - 3Nos for Metering
Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set
MCB DBs
Supplying, fixing, connecting & commissioning the following Compartmentalised MCB DISTRIBUTION BOARDS fixed flush with the wall. All MCB DBs shall be double door only.
B Curve MCB should be used for Lighting DB
C Curve MCB should be used for Raw Power DB
D Curve MCB should be used for UPS DB
All Sigle Phase Distribution boards should be 7 Segmented DB.
All RCCB should be with 30mA breaking capacity
All DBs shall have incoming adopter box (Powder coated) to receive wires in pipes / cables etc. The adopter box shall have a minimum height of 150mm.
LIGHT DISTRIBUTION BOARD (LDB) 7 Segmented DB.
Common Area Lighting DB
Supply, ercetion, testing and commissioning of 4 way TPN DB with following specifications.
INCOMER : 40 AMPS 4 P MCB .. 1 No.
OUTGOING :
32 AMPS D P 30 mA RCBO .. 3 Nos.
6/10 AMPS SP MCB .. 12Nos.
EMERGENCY LIGHITNG DISTRIBUTION BOARD (ELDB)
Supply, ercetion, testing and commissioning of 8 way SPN DB with following specifications.
INCOMER : 32 AMPS DP RCCB .. 1 No.
OUTGOING :
10/6 AMPS SP MCB .. 6nos.
CRITICAL DB
Supply, ercetion, testing and commissioning of 8 way SPN DB with following specifications.
INCOMER : 32 AMPS DP RCCB .. 1 No.
OUTGOING :
10/6 AMPS SP MCB .. 6nos.
POWER DISTRIBUTION BOARD (PDB)
Supply, ercetion, testing and commissioning of 4 way TPN DB with following specifications.
INCOMER : 40 AMPS 4 P MCB .. 1 No.
OUTGOING :
32 AMPS D P 100 mA RCBO .. 3 Nos.
16/25 AMPS SP MCB .. 12Nos.
EXTERNAL DISTRIBUTION BOARD (EXDB)
Supply, ercetion, testing and commissioning of 4 way TPN DB with following specifications.
INCOMER : 40 AMPS 4 P MCB .. 1 No.
OUTGOING :
25 AMPS D P 30 mA RCBO .. 3 Nos.
10/16/25 AMPS SP MCB .. 12Nos.
LIFT DISTRIBUTION BOARD (LIFT DB)
Supply, ercetion, testing and commissioning of 12 way SPN DB with following specifications.
INCOMER : 40 AMPS 4P MCB .. 1 No.
OUTGOING :
32 AMPS TP MCB .. 1 No.
16 AMPS DP MCB .. 1 No.
6 AMPS DP MCB .. 1 No.
PHE DB
Supply, ercetion, testing and commissioning of 12 way SPN DB with following specifications.
INCOMER : 63 AMPS 4P MCB .. 1 No.
OUTGOING :
25 AMPS SP MCB .. 4nos.
16 AMPS SP MCB .. 4nos.
CABLES/TERMINATIONS
Supply, Laying, connecting and commissioning the following 1.1KV Grade AYFY/YFY/YWY Under Ground cables with necessary clamps screws etc. and the cables shall be laid in trench/clamped along wall/column/laid in cable tray etc(the rates inclusive of suitable clamps, screws etc but exclusive of cable tray complete.
3C x 185Sqmm Al 11kV XLPE Cable ( HT CABLE )
3.5C x 240Sqmm Al XLPE Cable
3.5C x 185Sqmm Al XLPE Cable (FIRE PANEL)
3.5C x 150Sqmm Al XLPE Cable (PANEL)
3.5C x 70Sqmm Al XLPE Cable (APFC)
3.5C x 50Sqmm Al XLPE Cable (PANEL)
3.5C x 35Sqmm Al XLPE Cable upto isolator panel
4C x 10Sqmm Cu XLPE Cable (car elevator)
4C x 6Sqmm Cu XLPE Cable (PHE/LDB/PDB/EXDB)
4C x 6Sqmm Cu Flex Cable (LIFT)
3C x 6Sqmm Cu flexible Cable
Supplying, terminating, connecting & commissioning the above underground cables with double compression type glands with all sockets etc complete
Note : Single compression gland cane be used upto 120Sqmm cable and double compression glan can be used cable from 120Sqmm and above.
3.5C x 185Sqmm Al 11kV XLPE Cable ( HT CABLE )
3.5C x 240Sqmm Al XLPE Cable
3.5C x 185Sqmm Al XLPE Cable (FIRE PANEL)
3.5C x 150Sqmm Al XLPE Cable (PANEL)
3.5C x 70Sqmm Al XLPE Cable (APFC)
3.5C x 50Sqmm Al XLPE Cable (PANEL)
3.5C x 35Sqmm Al XLPE Cable upto isolator panel
4C x 10Sqmm Cu XLPE Cable (car elevator)
4C x 6Sqmm Cu XLPE Cable (PHE/LDB/PDB/EXDB)
4C x 6Sqmm Cu Flex Cable (LIFT)
3C x 6Sqmm Cu flexible Cable
ISOLATORS
100A 4P Isolator with IP55 Manufacture's enclosure MCB Type(Floor)
63A 4P Isolator with IP65 Manufacture's enclosure MCB Type(Lift)
40A DP Isolator with IP55 Manufacture's enclosure MCB Type(Inverter)
25A 4P Isolator with IP55 Manufacture's enclosure MCB Type(Pump)
25A DP Isolator with IP55 Manufacture's enclosure MCB Type(Mechanical parking)
EARTHING
Supply erection testing and commissioning of Maintenance Free Earthing system comprising of 14.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding & 1 bag of Carbon based Ecosafe environment friendly backfill and suitable clamp, as per IS 3043. CPRI test report should be produced at the time of supply including the inspection chamber, cover HDPE complete set.
DG Set .. 2 Sets
LT Panel .. 2 Sets
Lightning Arrestor .. 2 Sets
UPS .. 2 Sets
Lift .. 4 Sets
Supply erection testing and commissioning of Earth Electrodes, 17.2mm dia copper bonded steel rod 3meter length, 100 micron , along with jef corbon based ecosafe backfill compound 50 pounds , along with tin coated copper clamp.CPRI test report should be produced at the time of supply.including the inspection chamber, cover HDPE complete set.
DG Set .. 2 Sets
Tenants : 14 Set ( Space provision only )
Supplying, laying and connecting 50 x 6 mm. GI Flat laid in open fashion with necessary clamps,screws, interlinks etc for inter connecting, Typical floor, DG set & power Panel of the earth pits
Supplying, laying and connecting 25x 6 mm. Cu Flat laid in open fashion with necessary clamps,screws, interlinks etc for Neutral Earthing of DG Sets
Supplying, laying and connecting 25 x 6 mm. GI Flat laid in open fashion with necessary clamps,screws, interlinks etc for Body Earthing of Sub Panels Etc.,
Supplying, laying and connecting 25 x 3 mm. GI Flat laid in open fashion with necessary clamps,screws, interlinks etc for Body Earthing of Lift Etc.,
Supplying, laying and connecting 8SWG GI wire laid in open fashion with necessary clamps,screws, interlinks etc for earthing of All DBs ,Fans & AC Equipments
Supplying, laying and connecting 25 x 6 mm. 300mm Cu Flat AS EARTH LINK with necessary holes, complete set
Supplying, laying and connecting 50 x 6 mm. 500mm GI Flat AS EARTH LINK with necessary holes, complete set
Supplying, laying and connecting 25 x 6 mm. 400mm GI Flat AS EARTH LINK with necessary holes, complete set
Supplying, laying and connecting 25 x 3 mm. 400mm GI Flat AS EARTH LINK with necessary holes, complete set
CABLE TRAY
Supplying,erecting & connecting and commissioning Cable Trays of following measurements with necessary Box Channel for cable supports and other allied fabrication works. Fixing to concrete surfaces shall be done with the help of expandable type anchor fastners capable of bearing a weight of 500 Kgs. Fixing to brick walls shall be done by grouting. The distance between two supports shall be 2000 mm. The materials and labour for grouting, cable supports and other allied fabrication work shall supplied by the Contractor. The price includes all support for cable tray and allied fabrication works..etc complete along with necessary earthing of the cable tray with necessary 2R 25x 3mm GI Strip run along with cable tray. The price inclusive of GI strip and other accessories.
450 x 50 x 1.6mm perforated Type Cable tray with 2R 25x 6mm GI Strip
150 x 50 x 1.6mm perforated Type Cable tray with 2R 25x 3mm GI Strip
RAW POWER WIRING
Supplying, wiring, connecting & commissioning the Light Points with 2 Runs of 4 + 1R 2.5 Sqmm. PVC Insulated multistranded copper conductor FRLS wires (one each for Phase, Neutral and earth) in heavy duty 25mm MS Conduits in wall / Ceiling partitions or laid in open fashion above false ceiling with necessary clamps, screws, etc.,
Supplying, wiring, connecting & commissioning the Light Points with 3 core 4 sq.mm PVC Insulated multistranded copper conductor cable in heavy duty 32mm MS Conduits in wall / Ceiling partitions or laid in open fashion above false ceiling with necessary clamps, screws, etc.,
Supplying, and fixing 6/16 AMPS Switched Socket combined in 1.6 mm. thick in Manufacturer's mounting box fixed flush with the wall.
Supplying, and fixing 6 AMPS Switched Socket combined in 1.6 mm. thick in Manufacturer's mounting box fixed flush with the wall.
Supplying, and fixing 25 AMPS Switched Socket combined in 1.6 mm. thick in Manufacturer's mounting box fixed flush with the wall. (Ev charging)
LIGHT POINT WIRING
Mains Wirng (DB to Switch Board)(MCB in LDB to first point)
Supplying, wiring, connecting & commissioning the Light Points with2 Runs of 2.5 + 1R 1.5 Sqmm. PVC Insulated multistranded FRLS copper conductor/FRLS wires (one each for Phase, Neutral and earth) in already laid PVC Heavy duty Conduits laid in open fashion in wall / in ceiling with necessary clamps, screws, etc., MCB in the LDB to First light point
POINT WIRING
Average length (switch board to first point 6 to 8M)
Average length (first point to Second Point -3M to 5M, in MCB controlled light)
Supplying, wiring, connecting & commissioning the Light Points with 3 Runs of 1.5 Sqmm. PVC Insulated multistranded copper conductor FRLS wires (one each for Phase, Neutral and earth) in already laid 25/20mm heavy duty PVC Conduits in wall / ceiling with necessary clamps, screws, GI Flexible Hose, etc., including supplying and fixing 6 AMPS Switch in Manufacturer's mounting box fixed flush with the wall
One Light Controlled by one Switch.
Two Light Controlled by one Switch.
Three Light Controlled by one Switch.
Four Light Controlled by one Switch.
Five Light Controlled by one Switch.
Six Light Controlled by one Switch.
Seven Light Controlled by one Switch.
Four Light Controlled by one MCB
Five Light Controlled by one MCB
Six Light Controlled by one MCB
Staircase Light one light Controlled by 2 way one Switch
CEIG APPROVAL
Preparation of TNEB Drawings, submission, getting drawing approval, arranging inspection, attending the defects with regard to electrical, getting safety certificate etc., The job includes submission of as built drawings. The contractor should submit 5set. It is the sole responsibilty of the contractor to get the required sanctions & approvals from the CEIG & to submit the same to the Employer in the allocated timeframe.
Preparation of TNEB Drawings, submission, getting drawing approval, arranging inspection, attending the defects with regard to electrical, getting safety certificate for DG SETS etc., The job includes submission of as built drawings. The contractor should submit 5set. It is the sole responsibilty of the contractor to get the required sanctions & approvals from the CEIG Safety certificate for DG SETS & to submit the same to the Employer in the allocated timeframe.
LIGHT FIXTURES
Supply Installation testing and commissioning of light fixtures
28W 4feet LED light
15W LED Ceiling light
15w Wall light
Bulk Head light with 9W Led Bulb
Mirror Light
Supply & Installation of Standard commercial roadway lighting poles of 4.0mtr height with control box, loop in loop out connectors, SP MCB , single straight arm luminaire fixing bracket of 1.5mtrs length , Pole earthing with 8SWG GI wire, interconnection between control box luminaire with 3cx1.5sq.mm copper PVC sheathed cable, necessary M.S base work for pole, 40mm GI Sleeves for cable in / out, excavation, concreting, coping etc., complete including required civil & fabrication works. Also including one-coat of red-oxide & two coat of approved enamel paint. As approved by Project Manager. Light Fitting Shall be of LED Type. Excluding LED light fixture
LED Street Light -50W
Ceiling fan
Exhaust fan
Supply & Erection testing and commissioning of 5 kVA UPS of following specification with 15 mins battery backup, complete set.
INVERTER
Supply & Erection testing and commissioning of 5 kVA Inverter of following specification with 90 mins battery backup, complete set.
PVC CONDUIT / PIPE
Supply and laying of heavy duty PVC conduit concealed in wall/floors/ceilings with necessary clamps, screw with 1 Run of 16SWG G.I. Fish wire Finishing of concealed pipes ( in side the wall) by chicken mesh, etc., complete set.
20mm heavy duty PVC Conduit for Telephone/Data
450mm heavy duty RCC hume pipe NP2 for power cable including 3 feet sand excavation & re filling. ( EB Cable )
300mm heavy duty RCC hume pipe NP2 for power cable including 3 feet sand excavation & re filling. ( EB Cable )
150mm heavy duty RCC hume pipe NP2 for power cable including 3 feet sand excavation & re filling. ( DG/Networking )
32mm hdpe pipe for external work
LIGHTNING PROTECTION
Design & Supply of Air Termination
Supply, design and testing of Early Streamer Emission (ESE) lightning conductor. Equipped with Stainless central pick up rod. Full electrical continuity between the tip and the earth point. Fully autonomous (no battery, no external power supply required). Collect energy through streamer emission controlled with detects the lightning and trigger a streamer (3,5KV and 20A). Manufactured as per CPRI Requirements Rating for which tested 5+ve and 5-ve lightning impulse current (8/20ms) of 70KA temperature in degree celsius 25 degree, atmosphere Pressure in mm of Hg680, relatire humidity rh%77 & Indian standard. Radius52mtr at LEVEL-4
Supporting Pole & stay arrangement
Supply of 5 mtr elevation pole made of GI with a dia of 40mm with a M20 thread at the top to fix the unit. Supplied with Bracket, clamps and all required fixing equipments.
Supply of Down Conductor
Supply of 50mm² insulated copper cable. As a down conductor
Supply of Lightning flash counter
SAFETY EQUIPMENTS
Supplying, erecting and connecting Treatment Chart in English and Local Language directly fixed on to the wall with necessary screws etc.
Supplying 440 V Gloves
Supplying, and laying 2000 mm. x 1000 mm x 3 mm. thick ISI Marked Rubber mats to be laid in Front of the Panel Boards.
First Aid Box
Supplying and fixing 440 V Danger Board.
CONSTRUCTION LIGHTING
Supply of Construction Lighting accessories such as Light fittings, Cables , Switches, & Sockets etc complete with all accessories
1. cable treanch not include in this above BOQ.
2. Earth excavation work not include in this above BOQ.
Item Wise BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
275kVA DG SET
220 KW/275 KVA Prime Power Rated Radiator cooled Type Diesel generating Set 415 V, Mounted on a Channel Iron Base Frame, Residential Silencers Flexible Bellows First Fill of Lube Oil, Radiator Coolant, Batteries Set of Foot Mounted AVM Pads Engine Controller Radiator Control Panel along with Acoustic Enclosure for outdoor application along with built in fuel tank etc.,
DG SET ACCESSORIES
Unloading and Positioning of the DG Set and its allied accessories in the prepared foundation.
6" MS Class B Exhaust Pipe Line for 275KVA from turbo to silencer inlet
8" MS Class B Exhaust Pipe Line for 275KVA from Silencer to Verticle height
Exhaust Pipe bends
"Y" Joint after Silencer
Thermal Insulation 50mm thick Mineral Wool and Cladding for Residential Silencer
Thermal Insulation 50mm thick Mineral Wool and Cladding of 8" MS Pipe Line for 275KVA
SS exhaust bellow after silencer
Lightning Arrestor, Aviation lamp including connecting accessories
DG set exhaust pipe size and insullation as to be OEM standard.
CONTROL WIRING
Supply laying and jointing of control cables between DG set , Power Panel ( Distance between DG Set & power Panel will be around 30 Mtrs.)
Vendor has to provide test certificate, drawings and approval from pollution control board or any other Govt. departments. (Excluding safety certificate from CEIG for safe installation of above DG set)
Civil works such as plat form for DG set shall be done by the client
All the panels should be compatible with BMS
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_942898.xls
BOQ • 2.13 MB
RD.pdf
Tender Documents • 7.28 MB
Part1.pdf
Tender Documents • 2.29 MB
Part3conditions.pdf
Tender Documents • 1.33 MB
SectionVIIAC.pdf
Tender Documents • 7.95 MB
SectionVIIBOHSE.pdf
Tender Documents • 2.82 MB
SectionVIICdrawings.pdf
Tender Documents • 18.16 MB
Download all tender documents and submit your bid