Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC The letter of Acceptance of tender | |
| 2 | L2₹18.8 L+₹2.9 L (17.9%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Meeting the eligibility criteria |
Tender Value
₹21.4 L
EMD Value
₹43,000
Closing Date
16 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer (Army) Mumbai
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
AUGMENTATION OF POWER SUP OF 600 KVA LOAD AT BTC BAMBOLIM
2020_MES_347659_1
83930/P/E8
Open Tender
Civil Works
Item Rate
180 days
GE PANAJI GOA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE PANAJI GOA
₹43,000
13 Jul 2020
27 May 2020
17 Jun 2020
27 May 2020
16 Jun 2020
4 Jun 2020
27 May 2020 - 9 Jun 2020
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard / Dense soil.
All same as per item No 1 above but depth exc 1.5 mtr but not exceeding 3 mtr.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose/hard/dense soil.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point.
M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Thickness of sand cushion after punning down i.e 18 Cm shall be measured for payment
M&L for PCC 1:3:6 type C2 (40mm graded aggregates) as in foundation, filling and mass concrete.
M&L PCC 1:4:8 type D2 (using 40 mm graded stone aggregate as in foundation filling and mass concrete
M&L for cement concrete 1:3:6 type C-1 using 20mm graded stone aggregates as in coping / pedestal of poles including necessary formwork complete all as specified and directed
M&L for brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and as directed.
M&L Cement concrete1:2:4 type BI in copings including weathering, slightly rounded for chamfered angles and throating.
M&L Cement concrete1:2:4 type BI in surface channels and drains using 20mm graded aggregate in place of 40mm.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
M & L for Bricks, sub class B, laid on edge in floors; old size bricks beded in CM 1:6 and jointed in CM 1:3.
M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces using WPC @ 3% by weight of cement, complete all as specified and directed. (Supply only water proofing compound shall be measured and paid for separately)
Supply only Integral water proofing compound, ISI marked, complete all as specified and directed.
M & L for pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in man hole covers etc set in cement mortar 1:4, complete all as specified and directed.
M & L for MS TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia all as directed and specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required, internal dia of pipe 150mm all as specified and directed.
M & L for RCC pipes class NP2 150mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed (excavation, earthwork and PCC shall be measured and paid for separately)
M & L Concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested; in cement concrete 1:4:8 type D2 bore of pipe 150 mm
S & L un-reinforced precast concrete cable cover , class , HV , Type I flat size 300 x 180 x 40 mm laid dry in trenches over under ground cables.
Supplying, Errecting and fixing in repair Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, complete all as specified and directed.( for Two pole structures - 01 No)
S & F XLPE insulated (Earthed) , screened PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with aluminium conductor, 11000 volts grade,3 core,cross sectional area 95 sq.mm including inspection and testing.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
All same as per item No 24 above but for Indoor Termination
S & F in repair 80 mm dia steel tubes, 'light grade', galvanised, with all fittings; laid in trenches/ fixed on wall/pole all as directed.
S & F 50 mm dia steel tubes, 'Med grade', galvanised, with all fittings; laid in trenches/ fixed on wall/pole all as directed.
All same as per item No 27 above but for 40 mm dia steel tubes.
All same as per item No 27 above but for 25 mm dia steel tubes.
All same as per item No 27 above but for 20 mm dia steel tubes.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of the size suitable for 50 mm dia GI PipE.
All same as per item No 31 above but for 40 mm dia GI Pipe.
All same as per item No 31 above but for 25 mm dia GI Pipe.
All same as per item No 31 above but for 20 mm dia GI Pipe.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed.
M & L for stringing and fixing in position of ACSR conductor in of any size as per site requirement including provision of aluminum binding wire complete all as specified and as directed.
S & F Pin type porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height and 150 mm dia suitable for working pressure 11000 Volts grade complete.
S & F switch air break gang operated horizontal type triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps 11000 volts grade complete all as directed.
S & F D O fuse unit 3 pole 11 KV channel mounted from 50 to 100 Amps complete
S & F Lightning arrestor suitable for HT, 11000 volt grade, non liner resistor type, horn gap and chocking coil with all fitting for outdoor use.
Surface excavation n. exceeding 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil in Transformer Yard complete all as directed.
Excavating in post holes( or similar holes) each n exceeding 0.5 cu.m, getting out ,returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm of surface in hard/dense soil for embeding fencing post.
Supply only Chain link MS Galvanized fencing 50mm Mesh x 3.15 mm dia of standard height 2.1 Mtr complete all as specified.
Fixing only chainlink fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) including demolition of old brick work built in cement mortar complete all as specified and directed.
M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar of 1:4 complete
M & L for Providing precast cement concrete slabs 10cm thick (with plain as directed) setting in cement mortar of 1:6 type B1 1:2:4, complete, all s specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Loose filling with aggregates of gauge 40 mm in Transformer Yard / Sub-station, deposited spread and levelled in layers not exc 15 cm watered and rammed to a true surface complete all as specified and directed.
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and fixed with MS clamps, bolts and nuts of approved size, for HT, 25X20cm size.
S & F HT 11 KV, 3 phase 50 cycles, outdoor type, totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity upto 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 400 Amp.
M & L for Earthing (OH/Sub station) with galvanised steel earth plate electrode 60 cm x 60 cm x6.3 mm hick, burried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connectedto main earth lead GI FI 32 mmx6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GE earh lead protected by GE pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soilto 50 metre, Main earth lead upto 7.5 metre incl of filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI llight grade watering pipe, earth test point, commissioning & testing complete.
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .