Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC LOWEST TENDERER. | |
| 2 | L2₹12.2 L+₹35,450 (2.99%)Rejected-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC NOT LOWEST TENDERER. |
Tender Value
₹12 L
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTANANCE OF CENTRAL AIR COOLING SYSTEM AT COMMAND BUILDING AT VSN NAGPUR
2022_MES_568044_2
8576
Open Tender
Civil Works
Item Rate
180 days
VSN NAGPUR
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
Exempted
10 Mar 2023
17 Jan 2023
20 Feb 2023
17 Jan 2023
13 Feb 2023
24 Jan 2023
Amount
Taking down electric motor 30/25 HP 415 volt coupled to blower pulley after disconnecting the electrical connection, and earth connections removing from its foundation and transporting to work shop , checking the serviceability of ball bearing both side of motor , greasing of bearing up to free rotation of shaft on re-assembling the motor complete, re-installation on foundation, re-connecting back the cable and earth connections and varnsihing, drying, opening, overhauling , greasing , alignment of motor with blower pulley poperly authorised mechnical including repair to foundation if required at site etc complete in all respect and starting the pump all as directed. Note: 1 Contractor shall be responsible for maintaining required RPM after repair ,non compliance of speed considered as incomplete repair. 2 Cost of rewinding & bearings shall be measured and paid separately under relevant item.
Taking down electric motor 0.5 to 1 HP 415 volt after disconnecting the electrical connection and earth connections removing from its foundation and transporting to work shop , checking the serviceability of ball bearing at both side of motor , greasing of bearing up to free rotation of shaft of motor complete re-assemblying the motor & re-installation on foundation, reconnecting back the cable and earth connections and alignment of pump/ motor poperly by authorised mechanic including priming of PVC foot valve etc complete in all respect and starting the pump all as directed. Note :1. Cost of rewinding , bearings shall be measured and paid separately under relevent item. 2. Contractor shall be responsible for maintaining required RPM including priming coat for motor for taking out water cellouse pads after repair ,non compliance of speed considered as incomplete repair
Supply only spare parts for motor of capacity 30/25 HP vide item No.1 as follows:-
a) Supply only motor shaft as per exiting site requirement complete
b) Supply only check nut.
c) Supply only ball bearing as per exiting site requirement fitted in motor complete Make : SKF/ Timken /NSK/ URB
Material and labour for painting with dark Blue colour of synethetic enamal paint of air blower motor of capacity upto 30 HP blower stand and floor of ambient chamber , water pump including motor of capacity 0.5 HP water pump after removing all dust, dirt etc and clean the surface thoroughly and applying two coats of synthetic enamel paint by spray painting including writing MES No. complete all as specified and as directed .
Material and labour for existing colour of synethetic enamal painting of LT motor control panel for central cooling system board mounted in floor after removing all dust, dirt etc and clean the surface throughly outer/inner side and applying two coats of synthetic enamel paint by spray painting including writing name of feeder / equipment complete all as specified and as directed .
Material and labour for Dismantling the motor,seperating the stator and rotor assembly ,cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding of stator with super enamelled solid copper conductor (winding wire) of appropriate gauge and size to match with the existing winding so as to acheive desired RPM including varnishing, drying, ovening, overhauling, greasing, provisioning insualtion and re-assembling stator and rotor , connecting coils/ winding in star and delta mode at the junction box/terminal , fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed.
(a) 0.5 upto 1 HP
Supplying and laying synthetic rubber insulated mats 2.0 mm thick for voltage upto 1100 V for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Material and labour for aluminium composite panel of 4 mm thick with 0.5 mm aluminium coil thickness complete including aluminium strip/angle for fixing the same over the nitrile insulation complete all as specified as directed.
Supply and fix industrial exhaust fan axial flow motor with blade and frame heavy duty copper wound industrial exhaust fan 36 inch / with IP 55 specification, rigid frame with rubber mounting for silent operation epoxy powder coated and better resistance to corrosion and acid alkali fumes , totally enclosed highly efficient single phase AC including taking down u/s exhaust fan complete all as specified and as directed.
Supply & fixing V belt for capacity of 30000 to 40000 cfm blower motor suitable for the existing plant size 32/20 including taking down u/s V belt complete all as specified and as directed.
Supply & install blower pully as per existing blower capacity fitted at site for air washer ambiator chamber including taking down old u/s pulley complete all as specified and directed Note : Sample available at AGE E/M office of GE (AF) Nagpur.
Supply and fix new nitrile insulation 13 mm thick nitrile rubber sheet fixed with suitable adhesive out side of duct/ inside of duct and air washer chamber for weather proofing Including taking down U/S old nitrile insulation / glass insulation complete all as specified and directed .
All as per item No 15 here-in-before but 25 mm thick nitrile rubber sheet.
Suply and fix aluminium strip 25x3 mm thick by providing suitable support for fixing of nitrile insulation inisde/outside of AHU and duct for air washer plant complete all as specified and directed . Note: The quoted rate shall deemed to be included cost for making holes in strip , nut bolts and washers etc all as specified and as directed,
Material and labour for scaffolding by using steel structure for repair of existing duct / duct insulation and rigidly supported for safe working up to height of 13 mtrs complete all as specified and directed . Note : The quoted rate shall deemed to be included cost for removing scaffolding after completion of repair work and cost of transportation and labour.
Supply and fix short neck of duct connected with air diffuser with long type and complete fixing with air sealed diffuser for avoiding of noise and air leakge includind taking down ol u/s neck of duct complete all as specified and directed . Note : If found leakge or noise in the duct or plant the contractorshall be responsible to repair the same without any extra cost of material and labour.
Supply and fix high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 60cmx60cm, having features low initial pressure drop, disposable,washable , maintenance free, compact design including taking down ol u/s part complete all as specified and directed . Note : Sample available at AGE E/M office of GE (AF) Nagpur. Make : Alpha Kel India/ AAF Camfil/ Freudenberg
All as per item No 20 here-in-before but suitable for existing plant size of filter 30cmx30cm.
Material and labour for cleanig of duct including rusted portion / dust settlement inside the duct including branches of each plant complete from AHU to final diffuser / opening all as specified and directed. Note: The quoted rate shall deemed to be included cost for painting of rusted portion of duct with red oxide primer.
Material and labour for comprhensive mainnence /overhauling /repair of complete air washer ambiator chamber including necessary oil / greasing , cleaning and realignment of motor properly by skilled technician if any motor require aliignment with blower of plant of capacity 10000 to 40000 CFM Grease gun shall be used for greasing whenever necessary all as directed Make of Greasing : Castrol/ Lithium Grease/ Servo MP3 Note :- The quoted rate shall deemed to be included cost for material and lobour for oil/ greasing.
Supply and fix aluminium grills for air supply made out of powder coated extruded aluminium adjustable type with variable angle and vertical and horizantal louvers and gape between louvers should be 25 mm with volume controls dampers including taking down ol u/s aluminium grills complete all as directed Make:- Aircon Airiqpment/Mapro/Air flow Note :- (a) The quoted rate shall deemed to be included cost for cutting of wall and POP work for fixing aluminium grill at site.
Taking down U/S Cellulose or celdek pads and supply and fix new consists for cellulose wood fibres in paper form . having high quality standard and posses on efficiency of more than 85% (sample available as AGE E/M office) Make Hutek/Munters/DRI Note : Damage portion shall only to be changed.
Supply and fix ball bearing for blower shaft as per existing type fitted in site for air washer ambiator chamber including takin down U/S complete all as specified and directed.
Supply & install motor pulley as per existing motor capacity fitted in site for air washer ambiator chamber complete including takin down U/S complete all as specified and directed.
Taking down old u/s exhaust fan heavy duty of size 36 inch , removing old unsv copper winding , rewinding the same with existing guage copper wire winding complete including testing after rewinding and repainting with existing colour and refixing in original position complete all as specified and directed.
Supply and fix MCB 4 pole 63 amps, breaking capacity 10 KA, confirming to IEC60947-2, 415 volts, 50 Hz including making necessary incoming and out going electrical connection with suitable size of copper lugs etc. including taking down old MCB complete all as specified and directed. Make : Legrand Cat No. BB40630B or equivalent in Hager/ Siemens/ L& T/ Schneider
Supply and fix MCCB 4 pole 250 amp , breaking capacity 36 KA (Thermal magnetic TM- d trip unit) 415 volts, 50 Hz confirming to IEC60947-2 including necessary incoming and out going electric connection with suitable size of copper lugs etc ncluding taking down old MCCB complete all as specified and directed. Make : Legrand Cat No 408702 or equivalent in Hager/ Siemens/ L& T/ Schneider
Supply and fix single core PVC insulated 1100 volt grade heavy duty cable FRLS multistranded copper conductor and connection upto the electrical system of size 4 sqmm single core wire complete all as specified
All as per item No 31 here-in-before but of size 2.5 sqmm single core wire.
Supply and laying or fixing or passing through pipe testing and commissioning of 1100 Volts grade 'heavy duty" PVC sheathed armoured cable LT, XLPE insulated copper conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 16 sqmm nominal cross sectional area 3 core confirming to IS specification. (Make : Havells/Polycab /Finolex)
Taking out unserviceable burnt control wiring including unserviceable spares from control panel of central air cooling duct and Material and labour for new control wiring with FRLS copper wire of existing size and length by using suitable lugs/thimble etc complete including replacement of old unserviceable spares and making necessary setting to work the plant in auto mode complete all as specified and as directed. Note :- Spare part shall be measured and paid separately under relevant item.
Supply only RYB indicator complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only voltmeter CTs 0-500 Volt Digital type complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only ampere meter CTs 0-300 Amps complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only over laod relay range 0.2-15 A complete all as specified and directed. Make: Schneider/L&T/Siemens
Supply only auxillary contactor 2 NO-2 NC complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only on delay timer 0.2 to 60 second complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only push button start/ stop complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only red indication complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only yellow indication LED neon bulb complete all as specified and directed. Make : Schneider/ L&T/ Siemens
Supply only green indication LED neon bulb complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply and fix 4 sqmm copper wire for internal wiring single core FRLS including taking down u/s copper wire complete all as specified and directed. Make : Finolex/Polycab/Havells
Taking down u/s and supply and fix suitable size copper lugs complete all as specified and directed.
Supply only Add on 2 NO - 02 NC M MCX 9-80/MO 9-110 complete all as specified and directed. Make :- Schneider / L&T / Siemens
Supply only spreader link kit complete all as specified and directed. Make :- Schneider / L&T / Siemens
Material and labour for GI duct of difference sizes made out of 2.0 MM thick galvanised iron sheet of any size duly cutting , bending required shape, welding / revetting as required for different size ducts and making necessary arrangement for fixing the same with MS channel / angle / RCC slab etc including aking down old U/S complete all as specified and directed.
All as per item No 50 above but GI duct of sizes made out of 0.5 MM thick.
Material and labour for MS angle frame of different sizes as per requirement at site for installation of GI duct of different sizes including fabrication work ie cutting / welding / making hole etc including aking down old U/S complete all asspecified and directed.
Supply and fix MCCB 4 pole 125 amp, breaking capacity 25 KA, 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. including aking down old U/S MCCB complete all asspecified and directed. Make : L&T Cat No. EM90984OOLO or equivalent in Hager/ Siemens/ Legrand/ Schneider
All as per item No 53 above but MCCB 4 pole 63 amp. Make : L&T Cat No. EM90984OOHO or equivalent in Hager/ Siemens/ Legrand/ Schneider
Supply and fix MCB SP 6 to 32 amp, breaking capacity 10 KA, 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. including aking down old U/S MCB complete all asspecified and directed. Make : L&T or equivalent iin Hager/ Siemens/ Legrand/ Schneider
Supply only power contactor 3 pole 415V AC type 32A MNX 32, Make : L&T Cat No. CS94111 or equivalent in Siemens/ C&S/ Schneider/ Legrand
All as per item No 56 above but 25A MNX 25, Make : L&T Cat No. CS94110 or equivalent in Siemens/ C&S/ Schneider/ Legrand
Supply only electronic type electronic timer ST 100 with time range 3 to 30 second, 360 Volt - Make : L&T Cat No ST803280000 or equivalent in Siemens/ C&S/ Schneider/ Legrand
Supply and fix PVC insulated 1100 volt grade heavy duty cable FRLS multistranded copper conductor and connecting panel to Exhust fan to the electrical system of size 4 sqmm 3 core ncluding PVC Conduit/Flexiable conduit as per site requirement including aking down old U/S cable complete all asspecified and directed.
All as per item No 59 above but cable of size 2.5 sqmm 3 core.
Material and labour for providing earthing complete with copper plate of size 600 mm x 600 mm x 3.15 mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to copper earth strip 20x 3mm up to test point and icluding test terminal box with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note: copper earth wire and protection pipe upto 7.5mtr is deemed to be included in the quoted rate.
Taking down U/S and dismantlling of canvas Air washer to duct supply and fix high performance double layered flexible canvas duct to air washer. Make- Resistoflex/ Dnlop Aircon/Air equipment and spares
M/S SHARADA ASOCIATE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .