Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAdmitted-Finance | ₹4.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.8 Cr+₹87.3 L (22.0%)Admitted-Finance | ₹4.8 Cr+₹87.3 L (22.0%) | L2 | Admitted-Finance |
| 3 | L3₹5.4 Cr+₹1.4 Cr (36.1%)Admitted-Finance | ₹5.4 Cr+₹1.4 Cr (36.1%) | L3 | Admitted-Finance |
| 4 | L4₹5.8 Cr+₹1.8 Cr (45.8%)Admitted-Finance | ₹5.8 Cr+₹1.8 Cr (45.8%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S A.G. ENTERPRISES L1 | AMIT ENGINEERING CORPORATION L2 | PREMIER ENGINEERING COMPANY L3 | DEVYANSH CONSTRUCTION AND DEVELOPERS PVT. LTD. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | ST Pole 11 Mtr. SP-55 | 474 | No. | - | - | - | - |
| 2.00 | ST Pole 13 Mtr. SP-72 | 22 | No. | - | - | - | - |
| 3.00 | ST Pole 11 Mtr. SP-55 for Stud Pole | 15 | No | - | - | - | - |
| 4.00 | BOM of M+ 6 Type Tower for 33 KV Line. ( as per schedule) | 2 | No. | - | - | - | - |
| 5.00 | X-Arm Channel 100x50x6 mm V-type | 360 | No. | - | - | - | - |
| 6.00 | 11 KV Disc Insulator B&S type 70 KN | 1,224 | No. | - | - | - | - |
| 7.00 | 11 KV Disc Fittings B&S type 70 KN | 306 | No. | - | - | - | - |
| 8.00 | 33 KV Pin insulator | 1,305 | No. | - | - | - | - |
| 9.00 | 33 KV GI Pin with Nut & washer | 1,305 | No. | - | - | - | - |
| 10.00 | M.S. Angle Iron 65x65x6mm, 4300 mm long (5.8 kg/mtr.) bracing with clamp. | 73 | Set. | - | - | - | - |
Tender Value
₹6.6 Cr
EMD Value
₹6.6 L
Closing Date
11 Mar 2020, 2:00 pmClosed
S.E., E.W.C., Lucknow(MVVNL)
TIPE IV/3, TRANSMISSION STAF COLONY DEVA ROAD, CHINHAT,Lucknow
CONSTRUCTION OF NEW 33 KV INDEPENDENT FEEDER EMANATING FROM 132 KV PRIMARY SUBSTATION AMAWA, RAEBARELI TO AIIMS HOSPITAL, DISTRICT -RAEBARELI ON TURN-KEY BASIS.
2020_MVVNL_438969_1
25/EWCL/2019-20
Open Tender
Miscellaneous Works
Turn-key
180 days
RAEBARELI
As per Tender Documents
2 documents required · 2 mandatory
₹5,900
A/CNo.-0758002100009592,IFCS Code-PUNB0075800
₹6.6 L
S.E., E.W.C., Lucknow(MVVNL)
16 Mar 2020
24 Feb 2020
12 Mar 2020
24 Feb 2020
11 Mar 2020
24 Feb 2020
29 Feb 2020
ST Pole 11 Mtr. SP-55
ST Pole 13 Mtr. SP-72
ST Pole 11 Mtr. SP-55 for Stud Pole
BOM of M+ 6 Type Tower for 33 KV Line. ( as per schedule)
X-Arm Channel 100x50x6 mm V-type
11 KV Disc Insulator B&S type 70 KN
11 KV Disc Fittings B&S type 70 KN
33 KV Pin insulator
33 KV GI Pin with Nut & washer
M.S. Angle Iron 65x65x6mm, 4300 mm long (5.8 kg/mtr.) bracing with clamp.
M.S. Top Channel 125x65mm, 3200 mm (13.10 kg/mtr) with clamp, bolts, nuts and washers.
M.S. Channel 125x65mm, (3200mm+2000 mm ) (13.10 kg/mtr) for Cable Expouser DP.
MS Channel 100x50mm for Cable Stand
M.S. Angle Iron 65x65x6 mm (5.8 Kg /mtr.) for Cable Expouser DP/ Guarding.
G.I. Wire 6 SWG for Guarding.
Earthing of Pole/Rod by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
Earth wire clamp with nut & bolt
P.G. Clamp for Dog
33 kV SMC Number plate with clamp with N&B
33 kV SMC Danger board with clamp with N&B
Stone pad (300x300x75 mm)
Armour Rod with Ferrule for ACSR Dog Helical performed
Packing piece for Cross Arm
G.I. Barbed wire (2 Kg. / Pole)
Alluminium Binding wire-6 SWG ( 0.5 Kg./ Pole)
Alluminium paint
Post Office Paint
Red Oxide paint
E Bracket for 33 KV
F bracket for 33kV / Top Cleat
Turn buckle
Eye Bolt
Concreting of supports with plinth (0.268 Cu.m. each)
Concreting of supports with plinth (0.44 Cu.m. each)
Grouting and Plinting for Cable stand (0.44 Cu.m./Cable stand )
33 KV Stay complete ( Stay rod 20x1800mm, stay wire 7/8 SWG 10kg, stay clamp bolt & nut with concrete grouting).
Bolt, Nut and Washers all Size
Holding Clamp for ST / PCC/Cross arm/ Cable DP/ Stud Pole/ Guarding .
ACSR Dog Conductor
Tree cutting compensation
Single Core PVC Cable 1x400 sq.mm
Alluminium lugs
33KV 3x300 mm2 XLPE cable
Heat Shrinkable jointing kit for 33 kV 3x300 Sq. mm. XLPE outdoor
Heat Shrinkable jointing kit for 33 kV 3x300 Sq. mm. XLPE indoor
Heat Shrinkable Cable jointing kit straight through for 33 kV 3x300 Sq. mm. XLPE Cable
GI Pipe 150 mm Diameter
MS Pipe 150 mm diameter
RCC Pipe 150 mm diameter (2 mtr./ Pipe)
G.I.Holding clamp with bolts & nuts
Cable Holding Clamp with bolt & nuts
Hoisting of 33 KV cable with GI Pipe
Dilling and Laying of 3x300 sq.mm 33 KV, XLPE insulated underground cable in MS pipe (Pipe to be laid by HDD method), single circuit below minimum 1.5 mtr depth from ground level .
Drilling and laying of 33 KV 3x300 sq.mm, XLPE insulated underground cable using HDD method without using MS pipe, single circuit, below minimum 1.5 mtr depth from ground level.
Laying of 33 KV, 3x300 sq.mm XLPE cable (double circuit) by digging method depth minimum 1.2 mtr below ground level and 750 mm wide by excavation of earth. The work include supplying of fine sand , bricks, stone slab, refilling and ramming of the left out soil and levelling etc.
Cable route marker
High pressure Testing
Road Restoration Charges for Pucca Road Crossing and documentation , approval fee etc.
Road Restoration Charges for Kucchha Road Crossing and documentation , approval fee etc.
NHAI /Highway crossing charges documentation and approval fee etc.
Railway Crossing charges documentation and approval fee etc.
Forest crossing charges documentation and approval fee etc
Electrical Safety Department NOC charges documentation and approval fee etc
33 KV Pilfer Resitant metering Cubical with 33 KV Electronic TVM
33 KV CT / PT Unit for Pole mouted Outdoor Structure.
AMIT ENGINEERING CORPORATION
PREMIER ENGINEERING COMPANY
DEVYANSH CONSTRUCTION AND DEVELOPERS PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .