Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC 6 A FIRST MAIN NEAR JAMIYA MASJID ISLAMPUR ANNASANDRAPALAYA HAL VIMANAPURA POST BANGALORE 560 017 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560017 | L1 | Accepted-AOC accepted | |
| 2 | L2₹37.0 L+₹31,993.77 (0.87%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹38.4 L+₹1.8 L (4.81%)Rejected-Finance NO 1 1ST MAIN ANANDNAGAR ATRIA INSTITUTE OF TECHNOLOGY CAMPUS HEBBAL BANGALURU 560 024 | BENGALURU URBAN | KARNATAKA | 560024 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹39.4 L+₹2.7 L (7.49%)Rejected-Finance H NO 11 1 MATHRU NILAYA 7TH MAIN 3RD CROSS NEAR GAUTHAM COLLEGE OF PHARMACY BHUVANESWARINAGAR RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹43.5 L+₹6.9 L (18.7%)Rejected-Finance 1280 A 7TH MAIN ROAD 3RD CROSS PRAKASH NAGAR RAJAJINAGAR III STAGE BANGALORE 560021 | BENGALURU URBAN | KARNATAKA | 560021 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
5 Sept 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
CERTAIN REPAIRS TO AREA DRAINAGE VERTICAL STACKS MANHOLES PATH WAYS CULVERTS COMPOUND WALL SECURITY WALL FENCING AND PERIODICAL SERVICES TO COMPOUND SECURITY WALL FENCING KERB STONES ETC UNDER OF DGQA UNDER THE AOR AGE BR N OF GE N BNG
2022_MES_543611_1
8332
Open Tender
Civil Works
Item Rate
270 days
BNG
Class D Category a(i) or (ii)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹80,000
Yes
3 Oct 2022
5 Aug 2022
7 Sept 2022
5 Aug 2022
5 Sept 2022
22 Aug 2022
5 Aug 2022 - 20 Aug 2022
Amount
Demolition of brick/stone/boulder /precast concrete articles and precast concrete block built in cement mortar etc complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry, type C1 1:3:6 (using 20mm graded aggregate) set in CM 1:4 with solid blocks,exc 10cm in width and setting in mortar complete all as specified and as directed.
Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of debris outside MD complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as insurface channels and drains complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20 mm graded stone agg) as in coping, beching of manholes and similar work etc complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surface finished fair and even without using extra cement complete all as specified and as directed.
Demolition of RCC man hole covers and similar works complete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded agg) as in cover slab for man hole/drain, size 600mm x 900mm, 100 mm thick including necessary form work and reinforcement set in CM 1:4 complete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded agg) as in cover slab for man hole/drain, size 600mm x 1200mm, 100 mm thick including necessary form work and reinforcement set in CM 1:4 complete all as specified and as directed.
S&F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings including necessary scaffolding up to four storey building complete all as specified and as directed.
As per Serial No. 11 here-in-before, but 110 mm dia complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) Bends with access door of any radious including necessary scaffolding up to four stoery building complete all as specified and as directed.
As per Serial No. 13 here-in-before, but for 110mm dia complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) branch piece, single ( single Y ) eqal or unequal of any radius including necessary scaffolding up to four storey building complete all as specified and as directed.
As per Serial No. 15 here-in-before, but for 110mm dia complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) branch piece,Double ( double Y ) eqal or unequal of any radious including necessary scaffolding up to four storey building complete
As per Serial No. 17 here-in-before, but for 110mm dia complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) junction single, (Single T) equal or unequal of any radius including necessary scaffolding up to four storey building complete all as specified and as directed.
As per Serial No. 19 here-in-before, but for 110mm dia complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) junction Double, (Double T) equal or unequal of any radius including necessary scaffolding up to four storey building complete all as specified and as directed.
As per Serial No. 21 here-in-before, but for 110mm dia complete all as specified and as directed.
S&F stainless steel pipe holding clamp 150 mm long for PVC up to 110 mm dia pipe fixed with stainless screw including removing of old clamps including necessary scaffolding up to four storey building complete all as specified and as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed by Engr-in-Charge
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry or laid dry and pointed complete all as specified and as directed by Engr-in-Charge
M&L for Plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) 100mm thick as in sub base of foot paths, pavements etc complete all as specified and as directed.
M&L for chequered cement concrete tiles 300 x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment, including screed bedding layer in cement mortar 1:4, 15mm thick, in flooring, complete all as specified and as directed.
M&L for 100mm thick Plain cement concrete 1:5:10, type E-2 (using 40mm graded stone aggregate) as in sub base of pavement complete all as specified and as directed.
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for Rubber moulded Machine pressed precast concrete interlocking paver block with grey cement and pigments any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed.
Demolition of existing roof treatment of any type including cement plaster 15 mm thick and providing screed bed/rendering 10mm thick in CM (1:3) mixed with and including supply of approved water proofing compound as per manufacturers instructions by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed.
M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, levelling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
As per Serial No. 34 here-in-before, but for plain sheet for ridge complete all as specified and as directed.
S&F rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisting and fixed in position on roofs including fittings & dismantling the old unserviceable water tank, complete all as specified and as directed.
As per Serial No. 36 here-in-before, but for 1000 litre capacity complete all as specified and as directed.
S&F in repairs 20mm bore dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed.
Disconnecting existing tanks with capacity exc 250 litres & n exc 500 litres, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning, repairing etc. measured separately) complete all as specified and as directed.
Disconnecting existing tanks with capacity exc 500 litres & n exc 1000 litres, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning, repairing etc. measured separately) complete all as specified and as directed.
Taking up or down 15 mm existing steel tubing and connections all as specified and as directed.
Taking up or down 20 mm existing steel tubing and connections all as specified and as directed.
Supply & laying 20 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials complete all as specified and as directed.
Supply & laying 25 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials complete all as specified and as directed.
Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement (External Surfaces) complete all as specified and as directed. Note :- WPC will be measured and paid separately.
Supply only integral liquid water proofing compound
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over one coat of primer on walls including in narrow widths/ bands etc complete all specified and as directed.
M&L for complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls and applying one coat of white wash including in narrow widths/ bands etc complete all specified and as directed.
M&L for preparation of old decorated surfaces of walls and applying two coats of white wash including in narrow widths/ bands etc complete all specified and as directed.
M&L for preparation of old decorated surfaces of ceilings and applying one coat of white wash including in narrow widths/ bands etc complete all specified and as directed.
M&L for preparation of old painted steel and iron surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
M&L for preparation of old decorated surfaces of walls including washing, rubbing down and stopping and applying one coat of oil emulsion distemper all as specified and directed.
M&L for preparation of old decorated surfaces of walls including washing, rubbing down and stopping and applying two coats of oil emulsion distemper including minimum 1mm thick wall care putty all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling including washing, rubbing down and stopping and applying one coat of oil emulsion distemper all as specified and directed.
M&L for preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying one coat of cement base paint at any position complete all as specified and directed.
M&L for preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying two coat of cement base paint at any position complete all as specified and directed.
M&L for preparation of old plastered surfaces of any description over 10cm girth or width and applying one coat of plastic emulsion paint of approved tint complete all as specified and as directed. MAKE : Royale luxury emulsion of Asian paint /silk luxury emulsion of Berger Paints / Satin stay bright of ICI Dulux
M&L for French polishing on old polished wooden surfaces of any description, width or girth exc 10cm including cleaning and preparing the surfaces with two or more coats including a coat of wood filler all as specified and as directed.
M&L for complete removal of existing treatment on walls of any description over 10cm girth or width and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over a 1 mm thick coat of plaster of paris to preapare the surfaces even and smooth on walls including in narrow widths/ bands etc complete all specified and as directed.
M&L for 4 mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 Sqm in each pane incl hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
M&L for 4mm thick Sheet glass, ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm in each pane incl hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
M&L for Rendering 15mm thick in CM 1:6 on brick or concrete surfaces , finished even and smooth with out using extra cement (Internal Surfaces) complete all as specified and as directed.
M&L for Rendering 5 mm thick in CM 1:3 on ceiling surfaces, finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash including in narrow widths/ bands etc complete all specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over one coat of primer including in narrow widths/ bands etc complete all specified and as directed.
Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including the roots after ensuring complete de-germification of palnt/weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings upto four storey high, complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
TCR CONSTRUCTIONS
Eeguchi Constructions
S SUDHAKAR
Suresh painters
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .