| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.7 L+₹3.4 L (32.5%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹14.3 L+₹3.9 L (37.6%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
22 Jan 2024, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF CEILING FANS, AIR CIRCULATOR, EXHAUST, GEYSERS AND ALLIED WORKS SERVICES FOR OTM ACCN AT JAIPUR MIL STN UNDER GE (S) JAIPUR
2023_MES_634419_1
GE(S)/J-55P/2023-24 8853/E8
Open Tender
Civil Works
Item Rate
270 days
Jaipur
Class E and category b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹30,000
Yes
30 Mar 2024
26 Dec 2023
31 Jan 2024
26 Dec 2023
22 Jan 2024
9 Jan 2024
Amount
Taking down carefully existing storage type Geyser 25/50 litres capacity for repair complete overhauling including cleaning of geyser assembly inlet outlet pipe etc and re-fixing in position complete all as specified and as directed.
Cleaning and preparation of outer surface of Geysers 25/50 litres capacity and painting with two coats of white synthetic enamel paint complete all as specified and as directed.
M&L for opening of geyser 20/50 litres capacity in position for carry out minor repair such as loose connection testing of thermostat, heating element, tightening of screws, PVC connection, bottom assembly pressure release valve, indicator etc. complete all as specified and as directed. Note :- Any major item required in measured and replacement shall be paid separately as supply only.
Supply only Stainless steel inner tank of capacity 25 Ltr.
Supply only Stainless steel tank of capacity 50 Ltr.
Supply only Glass wool/ rock wool for thermal insulation.
Supply only Outer tank made of MS sheet powder coated suitable for 50 Ltrs.
Suppy only Outer tank made of MS Sheet powder coated suitable for 25 Ltrs.
M&L dismantling of bottom assemble and de-scaling with acid and wire mess brush cleaning and refixing the same.
Suppy only PVC insulated and over all PVC sheathed copper conductor wire of size 2.5 Sqmm x 3 core, Lead wire with ISI marked.
Supply only Plug top 3 pin, 15 Amp rating ISI marked.
Supply only replacement of heating element of capacity 1.5 KW ISI marked.
Supply only heating element of capacity 2 KW ISI marked.
Supply only heating element of capacity 1.5 KW having 115mm dia base with 6 hole with diaphram washer suitable for geyser 25 litre capacity.
Supply only heating element Clip on made of copper, capacity 2 KW ISI marked.
Supply only Geyser bottom assembly of 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity Geysers as per requirement with the same make which is to be replaced.
Supply only Pressure release safety valve for Geysers spring loaded suitable for 15mm pipe chromium plated.
Supply only thermostat ISI marked of any make/ capacity of geyser.
Supply only thermostat ISI marked suitable for geyser venus T105 type TBS 16 A 250 Volt
Supply only thermostat ISI marked suitable for geyser make Bajaj with 2 male terminals and round base.
Supply only neon indicator lamp round or rectangular type.
Supply only PVC flexible connection hot and cold, high strength, impeccable finish, corrosion resistance 450mm long for geyser
Supply only PVC flexible connection hot and cold, high strength, impeccable finish, corrosion resistance 600mm long for geyser
S&F repair GI tubes 15mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors, complete all as specified and as directed.
S&F in repair 15 mm bore Angle stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 90gms), complete all as specified and as directed.
S&F in repair 15 mm Bib taps , cast copper alloy with crutch of butter fly handle screwed down , screwed for iron pipe or for brass ferrule, fancy type and fixed complete all as specified and as directed.
Disconnecting electrical connection and water connection and dismantling/ taking out Geyser of any make and capacity from any place and installation, commissioning and testing to another location including grounting nut and bolts with washers or with fasteners and testing complete all as specified and as directed.
M&L in repair Point wiring using approved colour coding as per IS, with stranded copper conductor 2.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, confirming to IS-694/ISI marked in and including PVC casing caping 25mm, medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coated and including mounting frame and over cover plate, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connected FRLS cable 1100 V grade as continuous earth wire to earth dolly for 3 pin switch socket outlet15Amp independent board complete all as specified and as directed including taking out old with switch and sockets.
S & F Switch Piano type type 230/ 250V grade on top covers 16 Amp, complete all as specified and as directed.
S & F Socket outlet multipurpose use, non/shuttering non/ interlocking flush mounting type, 230/250 Volts grade on top covers 16 Amp, complete all as specified and as directed.
Repair to solar water heater Descaling of solar collectors with acid (dilute)for solar water heater panel of 200 LPD as recommended by manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
Descaling of solar collectors with acid (dilute)for solar water heater panel of 100 LPD as recommended by manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
Taking down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) competer for solar panel 3 Nos suitable for 200 LPD having 6 Nos tubes in each panel, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mounting as recommended by manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
Taking down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) competer for solar panel 1 Nos suitable for 100 LPD having 6 Nos tubes, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mounting as recommended by manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
Supply and replace hose pipe for hot and cold water as per existing
Taking out U/S gate valve and supply and fixing of gate valve 15mm dia ISI marked complete all as specified and as directed.
Taking out U/S gate valve and supply and fixing of gate valve 20mm dia ISI marked complete all as specified and as directed.
Supply and replace U/S electric back up element 240 volt AC supply 3KW rating ISI marked including thermostate all as per sample, complete all as specified and as directed.
Supply and replace U/S electric back up element 240 volt AC supply 5 KW rating ISI marked including thermostate all as per sample, complete all as specified and as directed.
Taking out old rusted GI pipe including supply and fixing GI pipe 20 mm bore ISI marked medium grade complete as specified and as directed.
Repair to leakage for existing solor heater panel of 200 LPG complete all as specified and as directed.
Supply & replace following unserviceable item from sheet metal enclosure complete 240 Volts, AC supply.
Metallic Plug top.
Metallic socket
MCB 5 to 32 Amp, 10 KA, SP "C' Series
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 amp MCB 240V 'C' series complete all as specified and as directed.
S & F in replacement of rusted Angle iron of size 40x40x5 mm for supporting Solar panels on roof top including welding and fixing with suitable nut bolts and washer complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 in cement concrete for grouting angels in roof surface with using 12.5 mm graded stone complete all as specified and as directed.
Taking down carefully existing ceiling fans/wall fans of any make and sizes from ceiling/wall ,cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and reassembling after replacement of rubber real, wall fan blade , wall fan bracket ,MS nuts and bolts , split/safety pins and fan connector including replacement of old existing flexible cord connected from ceiling rose to fan through down rod and refixing and rehanging the same in existing position complete all as specified and as directed. Note: Rewinding shall be measured and paid separately under respective item.
M &L for dismantling of worn out/burnt out ceiling fans 1200 mm sweep Fans/Wall fans 200/400 mm and re-winding the ceiling fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and as directed.
All all as per serial item No 47 here in before but for Ceiling fans of 1400 mm sweep. Note:- (a) Repairs under serial item No 46 here in before shall be carried out at the site of work. Where as fans for repair under serial item No 47 and 48 shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. (b) Rewinding under srl item No 47 & 48 shall be done with winding machine (c) Fans will be given to contractor for rewinding under Gate Pass in Lots of appx 50 Fans and the same shall be returned by contracter in 10 Days time after all repairs and painting.And the panelity for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. (d) Spare parts like ball bearing, gun metal bush, capacitors and canopy required for repair/overhauling shall be measured and paid separately under relevant item of this schedule as supply only
Supply only ball bearing suitable for ceiling fans of any make, type and size.
Supply only bush made out of Gun metal suitable for ceiling fans of any make, type and size.
Supply only capacitors 2.5 MFD suitable for ceiling fans of any make, type and size.
Supply only canopy suitable for ceiling fans of any make, type and size.
Supply only down rod suitable for ceiling fans of any type and any size as per Sample/approved by GE complete all as specified and as directed.
Supply only clamp with nuts & bolts & locking pin suitable for ceiling fans of any make, type and size.
Supply only replacement rubber reels suitable for ceiling fans of any make, type and size.
Supply only fan regulator Piano type for ceiling fans of any make, type and size.
Supply only Ceiling cover Plate circular type for ceiling fans of any make, type and size.
Taking down carefully existing exhaust fans / PVC Air Freshner Fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fan and , refixing the same in position complete all as specified and as directed. Note:- Rewinding and spare parts like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule.
M &L for dismantling of worn out/burnt out Exhaust fans/ / PVC Air Freshner Fans 200 mm to 300 mm sweep and re-winding the exhaust fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut, bolt and washer complete all as specified and as directed.
M &L all as per serial item No 59 here in before but for Exhaust fans of size above 300 mm but up to 450 mm sweep, complete all as specified and as directed. Note: - (a) Repairs under serial item No 58 here in before shall be carried out at the site of work. Where as fans for repair under serial item No 59 and 60 shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. (b) Exhaust fans will be given to contractor for rewinding under Gate Pass in Lots of appx 50 Exhaust Fans and the same shall be returned by contracter in 10 Days time after all repairs and painting and the panalty for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. (c) Spare parts like ball bearing & capacitors etc required for repair/overhauling shall be measured and paid separately under relevant item of this schedule as supply only
Supply only ball bearing suitable for exhaust fans of size from 200 mm to 300 mm sweep.
Supply only capacitors 4.0 MFD for exhaust fans of size 300 mm to 450 mm sweep.
Material and labour for preparation of old surfaces of Exhaust fan by scraping out old paint with the help of emery paper/ wire brush including filling the cavities and painting with two coats of grey paint for exhaust fans and exhaust fan louver over a coat of red oxide primer with the help of spray machine complete all as specified and as directed.
S&F in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 250 mm to 300 mm sweep complete all as specified and as directed.
All as per serial item No 64 here in before but for exhaust fans above of size 300 mm to 450 mm sweep complete all as specified and as directed.
S&F in replacement of worn out nuts and bolts for fixing of Exhaust fans including finishing the disturbed surface of wall complete all as specified and as directed.
Supply and fix in replacement for PVC insulated and over all PVC sheathed copper conductor wire of size 1.5 Sqmm x 3 core, flexible wire ISI marked, for connection of fan from ceiling rose to fans complete all as specified and as directed.
M &L for hanging clamps with provision of hook made out of MS flat of 20mm x 3mm length 15 cm with suitable size nut, bolt and washer complete all as specified and as directed.
M &L for ceiling rose surface bakelite 65X50 mm, three terminal complete all as specified and as directed.
M/s Prakash Enterprises
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .