Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹51,091
Closing Date
16 Aug 2022, 4:00 pmClosed
EXECUTIVE ENGINEER (ELECT.)
BSNL ELECTRICAL DIVISION-I, EASTERN COURT, JANPATH, NEW DELHI-110001
Op. and non comp. mtce. of Microprocessor HVAC System of capacity 5x100TR, 3x100TR Chilling machines with reciprocating comp. and air cooled cond. and 2x100TR chilling machines with screw comp. and Air cooled cond. at BSB, Janpath, ND
2022_BSNL_125148_1
17/NIT/E-Tender/2022-23/ED-I
Open Tender
Electrical Works
Item Rate
180 days
NEW DELHI
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
A.O.(Cash) o/o CGM BSNL, NTR, New Delhi
₹51,091
18 Aug 2022
8 Aug 2022
18 Aug 2022
8 Aug 2022
16 Aug 2022
8 Aug 2022
SH-I Man Power
Operation Of Microprocessor based HVAC machines with capacity of 5 x 100 TR (3 Nos. of 100 TR Chilling machines with reciprocating compressor & air cooled condenser and 2 Nos. 100 TR chilling machines with screw compressor and Air cooled condenser) as detailed in Annexure- I ,by deputing the following staff: Skilled Unskilled Supervisor 6 AM to 2 PM 2 2 0 2 PM to 10 PM 2 2 0 General Shift 9AM to 5 PM 0 0 1 Note : The Work includes: i) Operation of the Pumps i/c releasing of the Air from the Pumps and water pipe lines. ii) Operation of AHUs & TFA units of different floors iii) Operation Of the electrical panels iv) Recording readings of all chillers, AHUs , pumps by providing Logbook & recording temperature readings of the different floors by providing digital v) To attend the floor complaints and recording them in the register vi) Weekly washing of the AHUs Filters and AHUs room vii) Chemical Cleaning of the Chiller condenser coil and AHUs cooling coil as per requirement viii) General checking /testing and attending minor faults in the electrical panels , motors viz. tightneing of connections, replacement of thimbles etc. as required ix) Out of skilled manpower one skilled operator shall be Electrician x) To carry out leak test of the compressors, condenser coil with the help of soap solution
Sub Head II(Material , If required during the currency of contract
Repairing refrigerant circuit of 40 TR circuit of Voltas make chiller i/c pressure testing with nitrogen, leakage detections, brazing and repairing work, again nitrogen pressure testing and to hold nitrogen pressure of 24 hours, vacumisation of refrigerant circuit , vacuum break and charging of R22 refrigerant & commissioning of complete refrigerant circuit of chiller unit etc. as reqd.
Repairing refrigerant circuit of 60 TR circuit of Voltas make chiller i/c pressure testing with nitrogen, leakage detections, brazing and repairing work, again nitrogen pressure testing and to hold nitrogen pressure of 24 hours, vacumisation of refrigerant circuit , vacuum break and charging of R22 refrigerant & commissioning of complete refrigerant circuit of chiller unit etc as reqd.
Repairing refrigerant circuit of 40 TR/ 60 TR capacity circuit of Voltas make chiller i/c storage refrigerant into empty cylinder pressure testing with nitrogen, leakage detections vacumisation of refrigerant circuit vacuum hold and vacuum break & commissioning of complete refrigerant circuit of chiller unit etc. as reqd.
Repairing of the microprocessor of 40TR/ 60 TR circuit of 100 TR capacity chiller Voltas make i/c to make chiller functional, testing and commissioning etc. complete as required.
Repairing of the microprocessor of 40TR/ 60 TR circuit of 100 TR chiller of Voltas make by replacement of the faulty analog card i/c to make chiller functional, testing and commissioning etc. complete as required.
Repairing of the microprocessor of 40TR/ 60 TR circuit of 100 TR chiller of Voltas make by i/c programming of the controller, to make chiller functional, testing and commissioning etc. complete as required.
Providing and fixing of following items for existing 100 TR Chilling machines with reciprocating compressor & air cooled condenser i/c dismantling of existing defective parts from existing chiller unit ,fixing, connections, testing etc. as required:
Anti fridging cutout switch
Water differential pressure switch
Topping up of Refrigerant Gas R-22
Suction, discharge and compressor oil Pressure transducers
loading/ unloading solenoid valve Coil
LP,HP & OP cutout calibration with PLC
Controller display with FRC cable
Condenser fan MPD overload
MPD for condenser fan
Automatic Air Relief valve
Temperature sensor
Repairing of the Existing horizontal split casing type Kirloskar Make Centrifugal water pump (Model No. DSM 65/32A) by replacement of mechanical seal with new mechanical seal i/c Opening of the pump casing nuts & bolts , shaft, taking out the worn out part to the workshop , machining work and refitting it again, making motor and pump alignment etc. complete as per site requirement.
Dismantling of existing faulty bearing of chilled water pumps of 30 HP capacity and replacing of bearing with new one i/c testing and commissioning etc. complete as required.
Rewinding of 30 HP capacity , 3 phase, 1440 RPM motor stator with super enameled copper winding wire, ‘E’ class insulation i/c Varnishing, Baking cutting and dismantling old brunt winding wire, replacement of Bearing & Terminal plate, reassembling, re-installation, making motor & pump alignment ,testing, commissioning, loading unloading & to and fro cartage from site to work shop etc. as reqd.
Rewinding of 2 HP capacity Condenser fan motor stator with super enameled copper winding wire, ‘E’ class insulation i/c Varnishing, Baking cutting and dismantling old brunt winding wire, replacement of Bearing & Terminal plate, reassembling, re-installation, testing, commissioning, loading unloading & to and fro cartage from site to work shop etc. as reqd.
Providing and fixing of following items for the existing ZECO make AHUs of different floor i/c dismantling of existing defective parts from the AHU ,fixing, connections, testing etc. as required:
AHU Canopy Lamp
AHU Canopy door limit switch
AHU Canopy door hinges
AHU Canopy door handle
V Belt
Replacement of the following items of existing Electrical Panels i/c identifying and rectifying the fault ,dismantling of existing defective parts, fixing, connections, testing etc. as required:-
MNX-40 Contactor (Make: L&T)
MNX-32 Contactor (Make: L&T)
MNX-25 Contactor (Make: L&T)
MNX-18 Contactor (Make: L&T)
2NO+2 NC Add on Block (Make: L&T)
Overload relay MN 2 of range 20 to 33 Amps (Make: L&T)
Overload relay MN 2 of range 9 to 15 Amps (Make: L&T)
Overload relay MN 2 of range 4.5 to 7.5 Amps (Make: L&T)
SPP VSPD1
SPP VSPD2
ON/ OFF Push button with elements
LED Indication lamp ( R, Y, B, G )
Providing & Fixing of 63 Amp 4 Pole MCCB
Providing & Fixing of 20 Amp 3 Pole MCB
Glass Relay 8 Pin (220 Volt)
Timer ST-100 Make. L&T
6 Amp capacity HRC fuse
400 Amp Capacity HRC Fuses
160 Amp. Capacity HRC Fuses
125 Amp. Capacity HRC Fuses
Replacement of the defective/ broken tyre coupling of 40 /60 TR circuit of Voltas make chillers with new one i/c replacement of nut bolts, making motor & compressor connection/ alignment etc. complete as per site requirement.
Replacement of the defective/ broken tyre coupling of 30 HP capacity Kirloskar make pump with new one i/c replacement of nut bolts ,making motor & compressor connection/ alignment etc. complete as per site requirement.
Attending water leakages in the water pipe line i/c welding work and making water pipe line operational etc. complete as per site requirement
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.
125 mm dia.
100 mm dia.
Providing and fixing in position the industrial type pressure gauges with gunmetal/ brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
Remarks:
Note:- 1. 1. The Agency has to submit police verification record & ID proof of each staff. 2. The firm shall provide each staff with working cell phone. 3. The staff may be deputed for duty as per instruction of concerned SDE (E)/JTO (E). 4. Penalty shall be imposed in case of absence of any staff as per T & C of contract. 5. The GST / other Input Tax Credit (ITC) taxes shall be quoted by the firm as applicable as per latest amendments of GST Rules. 6. The contractor shall provide correct tariff heads & other details to enable BSNL claim Input Tax Credit. 7. Bidder must mandatorily quote for all GST components (CGST, SGST, and IGST) as required. 8. If annual maintenance contract charges are required to be quoted as per SOW, basic charges should be shown in column 4 & the Goods and Service Tax (GST) in column 7 to 12. 9. The bidder who submits the offer with concessional Goods and Service Tax (GST) shall submit the proof of applicable concessional GST. In case the Concessional GST is not creditable to BSNL it should be included in the price of the goods/services. 10. In case, dealer is registered under compounding scheme or any rule/notification where the BSNL is not eligible for input tax credit then the bidder should not disclose any amount in column 7 to12 & 14. 11. % age Rate of FF & Packing should be shown of basic unit price excluding all taxes & charges (i.e. as %age of col.4). 12. The FF & packing amount quoted shall not be subject to change after bid evaluation /ordering on account of change of copper, lead base price, change in duties & taxes of item etc. 13. Bidder must mandatorily mention HSN & SAC numbers. 14. Evaluation of bids: - The evaluation and comparison of responsive bids shall be done on the basis of Net cost to BSNL on the prices of the goods & Services (i.e. complete work) offered along with all applicable Taxes, packing Forwarding Freight & Insurance charges etc. exclusive of GST. Declaration by Bidder 1. We hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the GST Act introduced w.e.f. 1 July 2017 and further extended on more items till date. 2. We hereby certify that HSN/SAC shown in column 17 are correct & credit of GST for the amount shown in column 14 above are admissible as per GST Laws. Name of bidder: Seal of Company: GST No./(s)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .