Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹17.9 L+₹89,843 (5.29%)Rejected-AOC | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹18.0 L+₹98,505 (5.80%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹18.4 L+₹1.4 L (8.52%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹49,520
Closing Date
1 Mar 2021, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
DEVELOPMENT OF BOREWELL AND CONNECTED WORKS IN THE AREA OF AGE U WS III UNDER GE U WATER SUPPLY DELHI CANTT 10
2021_MES_418059_1
GE/WS/D-153 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹49,520
Yes
19 May 2021
2 Feb 2021
3 Mar 2021
2 Feb 2021
1 Mar 2021
16 Feb 2021
Amount
Disconnecting Electric connections from LT Control pannel and starter of submerssible pump set of any size 5HP to 20 HP and removing the pipe line connections from discharge side and taking out submerssible pump set along with, column pipe from bore well with the help of chain pully block for repair / development of borewell and lowering of same pump in bore well after repair including replacement of rusted nuts bolts, rubber gasket complete all as specifeid and as directed.
Labour for opening the submerssible pump set, repairing, rewinding and assembling the pump set including insulating material of any size 5HP to 20 HP capacity complete all as specified and as directed. make KSB, BS and Great India. ( Copper winding wire and other spare parts required for repairing will be measured under relevant item as supply only)
Supply only copper winding wire of existing gauge for submerssible pump sets of capacity 5 to 20 HP`
M & L Painting of submerssible pump set with two coat of synthetic enamel paint over a coat of red oxide primer.
Supply and fixing of GI Nippple with flange welded heavy duty 40 x 300 mm
Supply and fixing of GI nipple with flange welded Heavy duty 50 x 300 mm
Supply and fixing in replacement GI Column pipe 50 mm bore of 3 meter length Heavy duty duly flange welded on both ends complete all as specified and as directed
Supply and fixing in replacement GI Column pipe 80 mm bore heavy 'C' class of 3 meter length, Heavy duty flange welded on both ends complete all as specified and as directed
Supply and fixing in replacement of submersible copper cable of size 2.5 Sq mm 3 core, 1100 Volts complete all as specified and as directed
Supply and fixing in replacement of submersible copper cable of size 4.00 Sq mm 3 core, 1100 Volts complete all as specified and as directed
Supply and fixing in replacement of submersible copper cable of size 6.00 Sq mm 3 core, 1100 Volts complete all as specified and as directed
S&F in replacement moulded case circuit breakers 3 pole 100 Amps having breaking capcity 10 KA at 415 volts type DH-100 Cat Part No.CM98922OOOO
S&F in replacement moulded case circuit breakers 3 pole 63 Amps having breaking capcity 10 KA at 415 volts type DU-100 cat part No. CM97757OOOO
S&F in replacement 3 pole power contactor ML-2, 32 Amps 415 volts, 50 HZ suitable for fixing in existing panel Cat Part No SS-90701
S&F in replacement 3 pole power contactor MNX-25-, 32 Amps 415 volts, 50 HZ suitable for fixing in existing panel Cat part CS93110
S&F in replacement 3 pole power contactor MNX-32, 32 Amps 415 volts, 50 HZ suitable for fixing in existing panel Cat part CS93111
S&F in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel Cat Part No SS-91851
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD make L&T cat No SS91855
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-2.0 FASD make L&T cat No SS90705
Supply and fixing in replacement Electronic Timer
M&L in replacement of single phase preventor type VSP-II complete all as specified and as directed
S&F Numerical Motor protection relay with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic
S&F Submersible pump contriller MUG-6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic
S&F Thermal over load relay type ML-2/3 relay range 20-32 Amps
Development of borewell/ tube well with air compresser of rating 310-450 CFM with pressure line at 8 to 10 Kg per Sqcm complete all as specified and as directed. Note :- Rate quoted deemed to inclusive of necessary transportation of compressor & DTH/Rotary ring etc including other T&P required.
Supply and fixing in replacement of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed.
Material and labour for replacement of rubber packing suitable for flange 50 O 100 mm dia complete all as specified and as directed .
Supply and fixing well cap suitable for 250/300 mm bore pipe consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricated out of mild steel sheet 3.15 mm thick complete all as specified and as directed .
M&L for 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base.
M & L 50 mm thick sand filling under pavor block including spread and levelled watering and ramming consplidation etc complete all as specified and directed.
M & L 60mm thick factory made Machine pressed precast concrete interlocking paver block, M-35 grade rubberised any shape and size confirming to IS 15658-2006 Grade, with grey cement and pigment approved by GE and joints filled with and complete all as specified and as directed
M & K PCC type B-1 1:2:4 using 20 mm graded aggregate as in kerb & sides of hardstanding complelet all as specified and directed
M&L 20 mm thick rendering on concrete surface in cement mortar (1:4) surface finished even and smooth without using extra cement on brick/concrete surfaces including taking down complete all specified and as directed.
M&L 10 mm thick rendering in CM 1:3 of ceiling finished fair even and smooth without using extra cement including three coat of white wash on ceiling surface complete all as specificed and directed.
M&L for repair to steel rolling shutter including repair/replacement of locking arrangement, spring , greasing, one coat of synthetic enamel paint with existing colour complete all as specified and as directed
M&L in repalcement of Sign Board of size 600x450mm made out of 2 mm thick Stainless Steel and including marking of outer border in numerical and figure height 100 mm upto 20 Nos as per approved pattern complete all as specified and as directed
An amount of Rs 93630.00 shall be deducted from BOQ on account of schedule of credit
B.R. Enterprises
Sumit Enterprises
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .