Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | ₹27.9 L Quoted ₹29.7 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹35.9 LRejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | ₹35.9 L | L2 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 3 | L3₹36.6 LRejected-Finance 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | ₹36.6 L | L3 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 4 | L4₹36.7 LRejected-Finance | ₹36.7 L | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 5 | L5₹36.8 LRejected-Finance | ₹36.8 L | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
| Sl No | Description | Qty | Unit | K.P Construction Co L7 | ESS PEE UDYOG L6 | BHASKAR SUPPLY AGENCY L2 | JAY MA TARA TRADERS L1 | R T BUILDERS L4 | NIRMAL DAS AND CO. L5 | MS JYOTI INDUSTRIES L3 | SK CONSTRUCTION SYNDICATE & ENGG CO L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom suface to required level complete all as specified and directed
Note :- Rate inclusive of taking down and refixing any type of tile at sitte and making good as per exisitng | 294 | Cum | 350 ₹1.0 L | 350 ₹1.0 L | 295 ₹86,730 | 300 ₹88,200 | 325 ₹95,550 | 385 ₹1.1 L | 370 ₹1.1 L | 350 ₹1.0 L |
| 2.00 | Excavation in trenches not exc. 1.5 m wide and exc 1.5 m but not exc 3.0 m in deep in soft/loose soil for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom suface to required level complete all as specified and directed. | 7.3 | Cum | 600 ₹4,380 | 622 ₹4,540.60 | 500 ₹3,650 | 500 ₹3,650 | 460 ₹3,358 | 485 ₹3,540.50 | 450 ₹3,285 | 700 ₹5,110 |
| 3.00 | Returning filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed. | 136.1 | Cum | 140 ₹19,054 | 135 ₹18,373.50 | 180 ₹24,498 | 80 ₹10,888 | 98 ₹13,337.80 | 260 ₹35,386 | 145 ₹19,734.50 | 120 ₹16,332 |
| 4.00 | Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed | 161 | Cum | 220 ₹35,420 | 190 ₹30,590 | 260 ₹41,860 | 140 ₹22,540 | 160 ₹25,760 | 285 ₹45,885 | 180 ₹28,980 | 180 ₹28,980 |
| 5.00 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation base of poles and other similar locations including demoltion of old PCC/broken PCC complete all as specified & directed. | 4.5 | Cum | 6,800 ₹30,600 | 7,800 ₹35,100 | 6,800 ₹30,600 | 6,500 ₹29,250 | 8,200 ₹36,900 | 7,800 ₹35,100 | 7,000 ₹31,500 | 8,000 ₹36,000 |
| 6.00 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate with and including all necessary form work including demoltion of old PCC/broken PCC complete all as specified & directed. | 9 | Cum | 7,800 ₹70,200 | 9,000 ₹81,000 | 7,800 ₹70,200 | 7,800 ₹70,200 | 9,600 ₹86,400 | 8,800 ₹79,200 | 9,250 ₹83,250 | 9,800 ₹88,200 |
| 7.00 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form work and plastering to make good surface including demoltion of old PCC/broken PCC complete all as specified & directed. | 5 | Cum | 9,300 ₹46,500 | 9,100 ₹45,500 | 9,200 ₹46,000 | 8,500 ₹42,500 | 9,800 ₹49,000 | 9,000 ₹45,000 | 9,600 ₹48,000 | 9,900 ₹49,500 |
| 8.00 | Supply and Fixing in repair LED street light fitting of cap 90 Watt (or nearest higher Cap), and efficacy > 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die-cast aluminium IP65 protection with high power LEDs as light source, including all accessories for fixing or mounting complete all as specified and directed. | 20 | Each | 6,600 ₹1.3 L | 6,250 ₹1.3 L | 7,225 ₹1.4 L | 5,400 ₹1.1 L | 7,000 ₹1.4 L | 6,210 ₹1.2 L | 7,000 ₹1.4 L | 5,900 ₹1.2 L |
| 9.00 | Supply and Fixing in repair LED Street light fitting 60 Watt, and efficacy > 110 LPW 240 Volts new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device , connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed. | 20 | Each | 4,500 ₹90,000 | 4,180 ₹83,600 | 4,680 ₹93,600 | 4,000 ₹80,000 | 4,600 ₹92,000 | 4,725 ₹94,500 | 4,850 ₹97,000 | 4,800 ₹96,000 |
| 10.00 | Supply and Fixing in repair LED street light fitting 45 Watt, and efficacy > 110 LPW 240 Volts, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP66 protection and impact resistance of IK07 connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed. | 18 | Each | 3,380 ₹60,840 | 3,600 ₹64,800 | 3,650 ₹65,700 | 2,650 ₹47,700 | 3,280 ₹59,040 | 3,100 ₹55,800 | 3,380 ₹60,840 | 3,450 ₹62,100 |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
19 Dec 2025, 6:00 pmClosed
SHRI RAKESH KUMAR
GARRISON ENGINEER (CENTRAL) KOLKATA NAPIER ROAD HASTINGS 700022
REPAIR / MAINT OF STREET LIGHT, GARDEN LIGHTS, POLES AND OTHER CONNECTED ITEMS AT BMC AND AFCB UNDER GE (C) KOLKATA
2025_MES_742209_1
8883/E8
Open Tender
Miscellaneous Works
270 days
Kolkata
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(CENTRAL) KOLKATA
₹55,000
Yes
13 Feb 2026
29 Nov 2025
20 Dec 2025
29 Nov 2025
19 Dec 2025
14 Dec 2025
29 Nov 2025 - 13 Dec 2025
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom suface to required level complete all as specified and directed Note :- Rate inclusive of taking down and refixing any type of tile at sitte and making good as per exisitng
Excavation in trenches not exc. 1.5 m wide and exc 1.5 m but not exc 3.0 m in deep in soft/loose soil for laying of cables, GI pipe or filling of earth resistance enhance compound and getting out including levelling of bottom suface to required level complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation base of poles and other similar locations including demoltion of old PCC/broken PCC complete all as specified & directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate with and including all necessary form work including demoltion of old PCC/broken PCC complete all as specified & directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form work and plastering to make good surface including demoltion of old PCC/broken PCC complete all as specified & directed.
Supply and Fixing in repair LED street light fitting of cap 90 Watt (or nearest higher Cap), and efficacy > 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die-cast aluminium IP65 protection with high power LEDs as light source, including all accessories for fixing or mounting complete all as specified and directed.
Supply and Fixing in repair LED Street light fitting 60 Watt, and efficacy > 110 LPW 240 Volts new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device , connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed.
Supply and Fixing in repair LED street light fitting 45 Watt, and efficacy > 110 LPW 240 Volts, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP66 protection and impact resistance of IK07 connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed.
Supply and Fixing in repair LED flood light fitting for high mast of cap 150 Watt, and efficacy > 110 LPW 240 Volts 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
Supply and Fixing in rep[air LED flood light fitting of cap 120 Watt, 240 Volts, and efficacy > 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
Supply and Fixing in repair LED flood light fitting of cap 80Watt, 240 Volts, and efficacy_> 110 LPW 240 Volts energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
Supply and Fixing in repair post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection and efficacy > 110 LPW 240 Volts with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
Supply and Fixing in repair post top LED lantern of capacity 20 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection and efficacy > 110 LPW 240 Volts with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
S & F in repair focus light / spike light made up of dia cast,aluminium housing with stem efficacy > 110lm/w, AC 120-300V, CRI 70+, IP 66 rating ,10 watt in red/green/blue/ warm white with surge protection greater then 4KV & THD <10% with electrical connection complete all as directed.
Supply and fix in repair LED bollard light tulip shaped 9/10 watt capacity with opal acrylic IP 65 protection including necessary connection and including taking down old unserviceable one complete all as specified and as directed.
S&F in replacement LED drivers suitable for capacity 35 to 150 watt operating voltage 180v-270v AC 50/60 HZ out put voltage 36V DC/2.8 Amp power factor 0.95 for any make street light/Flood light complete all as specified and directed.
S&F in replacement surge protection device 10 KV for LED light fitting complete all as specified & directed.
S&F in replacement street light bracket made to shape out of GI pipe 32 mm bore light grade, 1.5 meter length fixed with & including necessary MS Clamps of size 40x5mm including nuts, bolts and washers on pole/wall etc complete all as specified and directed.
S&F in replacement 20mm rigid non-metallic PVC conduit inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified & directed.
S&F in replacement FRLS PVC insulated and PVC sheathed 2.5 sqmm 3 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
S&F in replacement FRLS PVC insulated and PVC sheathed 1.5 sqmm 3 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
S&F in replacement FRLS PVC insulated and PVC sheathed 6 sqmm 4 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
Prunning / trimming the branches of trees if any along pole, 3 mtr on all side below/ above/ sides of overhead line/pole and removing the same upto 150 mtr away & each span not exceeding 70 mtr etc complete all as specified and directed. Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required.
M&L for preparation of old painted surface of steel tubular LT poles 9m/11m long and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed.
Labour only for disconnecting, taking out defective under ground LT cable of length not more than 3 meter and of size upto 25 sqmm including excavation, taking out bricks cover and relaying the old cable in loop and making connection with proper new thimbles with cut out boxes, Feeder pillar box, MCBs etc including refilling of sand, relaying old bricks and returning, filling in soil etc complete all as specified and directed.
Taking out the old unserviceable LT underground cable of any size & any description 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc including brick cover complete all as specified and directed. Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Laying only in trenches bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. Note:- Old serviceable bricks obtained from taking down item shall be reused.
Supply , laying , jointing, testing and commissioning of size 10 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed. Note : Excavation, earth work, sand cushion & brick protection shall be paid separately.
All as per item No 33.00 here-in-before but of size 16 Sqmm 4 core complete all as specified and directed.
All as per item No 33.00 here-in-before but of size 25 Sqmm 4 core complete all as specified and directed.
S&F in replacement twin core flat 4 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
S&F in replacement twin core flat 6 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 50mm outer dia and 38 mm inner dia complete all as specified and as directed
S&F in repair MCB SPN of capacity 6A to 32A , 10 KA, type 'C', 240 volts complete all as specified and directed.
M & L steel tubular sewaged pole 9 mtr long completed with MS base plate, finial taper plug nut bolts, screws as specified type 410 SP-31 as per relevant IS specifiecation including two coats of aluminimum paint over a coat of red oxide primer including taking down old one all as directed by Engineer-in-Charge. Note : Earth work/excavation and PCC work shalll be measured and paid sepratly.
M&L for boring of holes under road / pavement / hard standing by any means and suitable for passing pipe and making good for both ends complete all as specified
S&F Straight through joint kit heat shrinkable 10 to 25 sqmm 4.0 core for LT 1100 Volts grade complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured conductor cable of following sizes including testing of cable after joints all as specified and directed.
M&L Rewinding of electric motor AC 3phase 415 volts 50- HZ of capacity upto 3 HP with supper enamel copper wire of same size and heating and vernishing after removing the old burnt out winding including replacement of bearing, transportation for repair and back etc testing & commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix Timer switch with ML2 CONTACTOR of Analogue type for street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed.
Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed
S & F in repair flexible LED strip is designed to perform in harsh outdoor with of power 6W/mtr in cool day white/warm white/blue/green/red/pink/ with system efficacy >100 IM/w, AC 120-300 V, 50Hz, 25,000 hrs, IP 65 ,PF:> 0.95 I SURGE PROTECTION :> 4KV & THD: <10%. with power adapter & electrical connection complete all as directed. Make- Magik Cat No. RUSR006 or equivalent in phillips, crompton, surya.
S & F in repair flexible LED strip light adapts to all shapes and sizes ,self adhesive 3M tape on the back ease of installation with an excellent colour consistency in coolday white / Warm white / Blue / Green /Red / Pink , system efficancy >110 Im/w ,AC 120-300 V, 50 Hz,25000 hrs,with IP 20 , PF:> 0.95 I SURGE PROTECTION :> 4KV & THD: <10%. with power adapter & electrical connection complete all as directed.
BHASKAR SUPPLY AGENCY (BID ID -3502347)
MS JYOTI INDUSTRIES (BID ID -3502344)
R T BUILDERS (BID ID -3502305)
NIRMAL DAS AND CO. (BID ID -3502757)
ESS PEE UDYOG (BID ID -3502295)
K.P Construction Co (BID ID -3501282)
SK CONSTRUCTION SYNDICATE & ENGG CO (BID ID -3502289)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TENDER8883.pdf
Tender Documents • 1.40 MB
BOQ_831114.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid