Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-AOC | ₹6.2 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹8.2 Cr+₹2.0 Cr (31.6%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹8.2 Cr+₹2.0 Cr (31.6%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹9.5 Cr+₹3.3 Cr (52.5%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹9.5 Cr+₹3.3 Cr (52.5%) | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹9.9 Cr+₹3.7 Cr (59.8%)Rejected-Finance | ₹9.9 Cr+₹3.7 Cr (59.8%) | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹10.1 Cr+₹3.9 Cr (63.1%)Rejected-Finance NOT SPECIFIED | ₹10.1 Cr+₹3.9 Cr (63.1%) | L5 | Rejected-Finance Being not lowest |
Tender Value
₹5.7 Cr
EMD Value
₹6.1 L
Closing Date
25 Sept 2020, 6:00 pmClosed
CE (AF) Gandhinagar
Lekawada Patia, Chiloda, Gandhinagar 382042
COMPLETION OF INCOMPLETE WORK FOR PROVN OF OTM ACCN FOR HQ MAO IAF AT PKT B SANTACRUZ AT AF STATION MUMBAI
2020_MES_359304_1
84157RCE8
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) Thane
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹3,000
GE (AF) Thane
₹6.1 L
Yes
7 Apr 2021
9 Jul 2020
28 Sept 2020
9 Jul 2020
25 Sept 2020
25 Aug 2020
16 Jul 2020 - 30 Jul 2020
Amount
NOTE: Schedule ‘A’ Part I to XV are under Ser No. 2.00 to 17.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Internal Water Supply as listed inSch `A’ Part II
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part III.
Lump sum price worked out for Excavation and Earth Work as listed in Sch `A’ Part IV
Lump sum price worked out for Hard standing/ Path as listed in Sch `A’ Part V.
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI.
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VII.
Lump sum price worked out for Security Wall as listed in Sch `A’ Part VIII
Lump sum price worked out for External Electrification as listed in Sch `A’ Part IX
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part X
Lump sum price worked out for Fire Fighting as listed in Sch `A’ Part XI
Lump sum price worked out for Lightening Arrester as listed in Sch `A’ Part XII
Lump sum price worked out for Lift as listed in Sch `A’ Part XIII
Lump sum price worked out for Fire Alarm System as listed in Sch `A’ Part XIV
Lump sum price worked out for Defects Rectification and Removal of Set Cement as listed in Sch `A’ Part XV
Lump sum price worked out for Provisional Lump Sum as listed in Sch `A’ Part XVI
SCHEDULE `A' PART - XVII [ MISC items (to be quoted by tenderers)] Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
EXTERNAL ELECTRIFICATION
Supply, install, test and commission of HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker with Three Modules ( 1- Incomer, 2- Out Going) with independent breaking mechanism, with motorized charging facility having rupturing capacity 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 800 Amp complete including taking down of old OCB/ACB/VCB of any capacity and size and depositing to stores all as specified and as directed by Engr-in-Charge.
(xix) Panel Ilumination CFL with Switch (xx) Breaker Racking Handle (xxi) Breaker handling Trolley (xxii) Necessary Provsion to Terminate Incoming and Out Going Cables (xxiii) Self powered Over current and Earth Fault Protection relay (xxiv) Cable cover standard with Interlocking (xxv) Cable bushings (xxvi) Motorized Breaker Charging Facility with Battery Back up (xxvii) Necessary Base Frames for Founation Note - Make of VCB Panel Shall be Siemens/ABB/Crompton
Supply install, test and commissioning LT Feeder Pillar board (CPRI Approved) cubical type Indoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 2mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75 x 40 mm duly coated with zinc entry of armoured cable metal coating. A detachable predrilled gland plateof thickness not less than 2 mm thick zinc metal coated
should be used at the bottom for of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and panel shall be powder coated ( for rust proof) sprayed of approved thickness coated complete as specified and consisting the following :- (i) Busbar Copper TPN 1200 Amps -1 Set. (ii) Incoming ACB 4 Pole 800 Amps 415 Volts, Microcessor Based, Draw out type - 01 No. (iii) MCCB FP 360 A 415 Volts 50 kA - 02 Nos (Bldg). (iv) MCCB FP 250 A 415 Volts 50 KA - 01 No (AMF) (v) MCCB FP 200 A 415 Volts 50 KA - 01 No (APFC) (vi) MCCB FP 120 A 415 Volts 25 kA 01 No (vii) MCCB FP 25 Amps 16 KA -02 Nos (viii) VAPFKWH Meter -01 No. Make - Make of VCB panel shall be Siemens / ABB /Crompton.
All as per Item 20 here-in-before but of Out Door Type made out of 3 mm thick CRCA sheet with the following incoming and outgoing feeders:-
(i) Busbar Copper TPN 600 Amps -1 No (ii) Incoming MCCB FP 360 A 415 Volts 50 kA - 01 Nos (iii) MCCBTP 50 Amps 415 Volts 35 kA - 01 Nos (iv) MCCB TP 40 Amps 415 Volts 35 kA - 01 Nos (v) MCCB TP 63 Amp 415 Volts 35 kA - 2 Nos (vi) MCCB TP 25 Amps 415 Volts 35 KA - 01 No (vii) VAPFKWH Meter (viii) Indicating Lamps LED Type - 03 Nos (ix) One No spare compartments fitted with dinrail for fixing MCCB of range 160 Amps 50 KA. Note : Make pf MCCB/ACB Shalbe - ABB/Siemens/
All as per Item 20 here-in-before but with the following incoming and outgoing feeders:-
(i) Busbar Copper TPN 200 Amps -1 No (ii) Incoming MCCB FP 63 A 415 Volts 35 kA - 01 No (iii) Outgoing (a) MCCB TP 40 Amps 415 Volts 35 kA - 02 Nos (Lift1, Lift2) (b) MCCB TP 25 Amps 415 Volts 35 KA - 01 No (Lift Lighting) (c) MCB sPN 32 A 230 V - 2 Nos (d) VAPFKWH Meter (iv) Indicating Lamps LED Type-03 Nos (v) One No spare compartments fitted with dinrail for fixing of MCCB of range 160 Amps 50 KA Note : Make of MCCB/ACB Shalbe - ABB/Siemens/.
All as per Item 20 here-in-before but with the following incoming and outgoing feeders:-
(i) Busbar Copper TPN 400 Amps -1 No (ii) Incoming MCCB FP 160 A 415 Volts 50 kA - 01 No. (iii) Outgoing (a) MCCB TP 63 Amps 415 Volts 35 kA - 02 Nos (Lift) (b) MCB SPN 63 Amps, 230 Volt - 08 Nos. (c) MCB SPN 63 Amps - 02 Nos. (d) VAPFKWH Meter. (iv) Indicating Lamps LED Type-03 Nos. (v) One No spare compartments fitted with dinrail for fixing MCCB of range 160 Amps 50 KA.
Supply and fix post top latern CFL type including all accessories and prewired suitable for and including S type CFL 1 x 18 watt CFL conforming to Cat No CFPT 18 of CG or equivalent from Philips, Bajaj complete including clamps, GI pipe braket, nuts bolts washers etc necesary for installation of the fittings all as specfied and as directed by Engr-in-Charge.
Supply and fix street light fittings energy efficient type all for 4 x 24 watt T5 lamp type complete with and including electronic ballast, side holders, fitting and 4 Nos of T5 24W lamps prewired complete. Make : HAVELLS Cat No.CRYPTON DD Series for T5,4x24W T5 HO,LHRF15424042 or Equivalent as approved by GE from Crompton Greaves,Bajaj (If Cat No is revised, equivalent Cat No from Latest Catlauge shall be considered)
Supply & Fix FRP looping / juction box prewired complete fitted with terminal connector block bakelite 8 way of 20 Amps rating with shorting strip copper, fitted with one Nos of MCB SP 05 to 30 Amps, 240 Volts for termination of incoming of incoming and outgoing cables, local connection to fittings complete all as specified and as directed by Engr-in-Charge. Make : Sintex Cat No.GSJB.2817 or Equivalent as approved by GE from Modi/Presto fit (If Cat No is revised, equivalent Cat No from Latest Catlauge shall be considered).
Supply and fix pole mounted out door type center openable double door street light timer panel fabricate from 3mm CRCA sheet with powder coated and including pole mounting MS brackets/clamps with nuts/bolts & the following accessories:- (a) MCCB, TPN, 25 Amps, 25 KA, 415 Volts - 01 No. (b) Timer FM 200 - 01 No. (c) Contactor three pole 415 volts, ML-2 type - 01 No.
Material and labour for cutting into the existing road/hard standing surfaces to a depth of 60cm and 50cm wide and getting out for laying under ground cable including returning filling in, watering, well ramming in layers not exceeding 25cm in any type of soil and filling the top surface 15cm thick with PCC 1 : 2 : 4 type B1 using 20mm graded stone aggregate and finished even and fair without using extra cement including disposal of surplus soil all as specified and as directed by Engineer-in-charge.
Material and labour for chemical earthing complete with copper plate electrode (98 percent conductivity when annealed) 1000 mm x 600 mm x 3 mm thick buried directly in ground ( Earth pit not less than 2.25 Meters deep below normal ground level and 1.3 mtr wide) with top edge of the plate not less than 1.5 mtr below ground level earth plate connected to copper strip (98 percent conductivity when annealed) 32 x 6mm (drawn in and including earth lead protection pipe light gade GI of size 65 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in Plate No 5 of SSR Part I connected to earthing lead , fillig with Charcoal 400 KG , dust and common salt 325 KG and Magnesium sulphate 100 KG, neccesary excavation and earth work in any type of soil, perforated watering pipe , funnel with wire mesh, earth lead protection pipe light grade PCC Chamber 1: 3 :6 type C1 ( for even finish on boh the faces ) and RCC cover 1:2:4 type B1, 550 x 550 x 50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 nos of handles of 10 mm dia Steel rod 500 mm Long all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc complete all as specified and as directed by Engr-in-Charge.Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and Earth lead . Any variation in length shall be adjusted through deviation order.(ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost.
EXTERNAL WATER SUPPLY
Supply, install, testing of centrifugal pump having Minimum discharge capacity of 4 LPS at minimum 40 Meter head 1450 RPM HP directly coupled with suitable induction motor AC 3 Phase, 415 Volts, 50 Cycles TEFC mounted on MS chaneel/Common base plate and fixed with suitable base bolts, grouted in PCC Foundation, 30 Cm above floor level including single core multi stranded PVC insulated copper conductor of 10 Sqmm size connection between starter & Motor Terminal, drawn through PVC conduit all as directed. Make Pump & Motor- Kirloskar/Crompton. (i) Brass Foot Valve (Make- Kirlosker/Venus) - 1 No Suitabe for Suction of Pump (ii) Flanged Gun Metal Butterfly Gate Valve valve - 1 Nos Suitable of Deliverry of Pump, (iii) Flange CGun Metal NRV - 1 Nos, Suitable for Delivery of Pump (iv) Suction pipes of Dia as Specified by Manufactures to a Length Not More than 9 Meters.
(v) Delivery pipes of Dia as Specified by Manufactures to a Length Not More than 6 Meters. (vi) Burden type pressure gauge on delivery of Pump set. (vii) Interconnection of Delivery mains. (viii) 20 mm GI Pipe line fo Priming. (ixi) 20 mm Gun Metal Late Valve (Priming Valve) - 1 No.
Material and labour for construction of for Valve Pit /Chamber in PCC solid block masonry (1:5:8) built in CM 1:6 ,over 150 mm thick PCC foundation 1:3:6 type C2, 10mm thick internal CM 1:6 & 12mm thick external plaster in CM 1:4 provided with 3 mm thick MS sheet cover and MS angle iron chamber frame fixed in coping in PCC 1:2:4 type B-1 with locking arrangement and handle, painting of MS work with one coat of red oxide primer and two coat of synthetic enamel black paint complete including excavation & earth work in any type of strata complete all as shown on drawing No.CEAA/TD/57sheet No 1.1,dated 28.05.92,amended upto 31.12.92, but of internal size 1200mm(L) x 1200mm(B) x 900mm (D) etc all as specified and directed by engineer-in-charge.
S&F gun metal Reflex valve threaded both sides of 50mm size all as specified and as directed by Engr-in-Charge.
Supply install test, commission & testing of Electrochlorination Plant capable to produce 1Kg of chlorine in 8Hrs in the form of hypo chlorite solution of strength 7-8gpl with and including the folowing acessories etc complete all as specified and as directed by Engr-in-Charge:-
(a) Power Pack unit:- (i) Rectifier Unit - 1 No. (ii) Transformer. (iii) Control Panel with Digital Voltmeter & Am meeter Make - Siemens/Enercon. (iv) Input and Out Put Cables. (b) Electrodes - Bipolar type with connecting brushes all made out of Titanium plate coated with multi metal oxide. (c) Electrolyser unit including acessories, PVC pipes & fittings, Rank of Capacity - 150 Ltrs. (d) Hypo Dozing Tank of Capacity 150 Ltrs. (e) Adid Bath Tank -of Capacity 50 Ltrs. (f) Hypo Dozing Pump Qty - 2 Nos with discharge of 12 LPH including starters, MCB & MCB DBs (g) Piping & Valvers as required for the smmoth function of the plant shall be included. (h) Cable & Conduict for the smooth functuioning of the Pplant incluing switches shall be included.
Supply install, test and commissioning LT Feeder Pillar board (CPRI Approved) cubical type indoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 2mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75x40 mm.
A detachable predrilled gland plateof thickness not less than 2 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and the panel shall be of Powder coated complete as specified and consisting the following :- (i) Busbar Copper TPN 200 Amps -1No. (ii) Incoming MPCB 3 Phase 50 Amps 415 Volts 35 KA -01 No. (iii) Outgoing MCB TPN 32 Amps 415 Volts - 01 No. (iv) MPCB 32 Amps 3 Phase 415 Volts - 03 Nos. (v) MCB SPN 16 Amps 10 KA 2 Nos. (vi) DOL Starter suitable for 3 Phase 3 HP to 7.5 HP Pump - 2 Nos. (vii) VAF PF Meter -01 No. (viii)Ammeter Conforming to DM 3258 of Conzerv - 02 Nos. (ix) Indicating Lamps LED Type-03 Nos. (x) One No spare compartments fitted with dinrail for fixing of MCCB. Make of MPCB/MCCB/Starter- Siemens/ABB/Schnider
Supply, install, testing of MCCB TP 40 Amps, 25 KA, 440 Volt, including factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate MCCB. The MCCB shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves all as specified and as directed by Engr-in-Charge.
SEWAGE DISPOSAL
Design, supply, installation, commissioning and testing including all civil, electrical mechanical works as per OEM specifications for packaged sewage treatment plant based on Hybrid of Aerobic and Anaerobic or based on Aerobic process of capacity 30,000 litres per day consisting of fiber glass reinforced plastic (FRP) tank made by chop hoop winding process from suitbale polyester resinb and glass fiber with hollow ribbing of polymetric material of 90mm thickness encased on the outside of the tank with suitbale polyster resin and fibre glass to make tank suitbale for underground application up to an over burden of 2.25 metres in soil having diamneter of 2.43 mtr with ususal process variation and having a length of 11.061 mtr with ususal process variation. The tank to have Zones-first Zone to work as anaerobic septic zone created with suitable partition of FRP with advanced polymeric media with a surface area 190 Sqm/Cum suitably encased in a polymeric net to allow free movement of he media within fixed space created by the net, the third zone to work as sedimentation zone in the remainder area of the tank Aerobic zone have Twin Lobe Air blower installed for providing air flow of minimum 1251 ltr/min by coarse aeration in the zone for speedy reductioin of BOD.
Sedimentation zone have submiersible pump of the size of 1hp for pumping the activated sludge back to the anaerobic zone by way of PVC pipes of 50mm dia on a regular basis. The whole plant to be controlled by automatic control panel made from sheet molded compound of size 900 x 400 x 1000mm consisting of other accessories such as PVC pipe fittings, 4 Nos FRP strap of 8000 mm length, 4 Nos turn buckle, 8 mtr wire rope, 4 Nos of conrete RCC block having dimention of 5530 x 300 x 300mm, 4 Nos manhole cover of 550mm size, 8 Nos eye bolt and 8 Nos of wire lock, of make Syntex/ION Exchange / Micro vision / Enzotech (solutions)/ Hydrotech Paryavaran (India) Pvt Ltd. Mohali. The input and output characteristic of effluent sewage and treated sewage are as given below: - Sl No. Description Input Output (i) PH 6.5-8 6.5-8 (ii) COD 600 mg/l < 100 mg / l (iii) BOD 275 mg/l < 30 mg / l (iv) SS 400 mg / l < 10 mg / l (v) Residual Chlorine - <1 mtr / l
FIRE FIGHTING
Supply and fix Canvasfire hose of dia 63 mm and length 15 meter of PIL Dura type conforming to IS 636/1988 Type - A, with proper exterior and interior coatings , including binding charges all as specified and as directed by Engr-in-Charge.
Supply and fix gunmetal hand controlled chromium plated branch pipe 63mmdia with 20mm Nozzle size with male insert provsion and incorporated with arrangments for Jet stream, spray and shut off etc. all as specified and as directed by Engr-in-Charge.
Supply and fix rubber hose of size 20mm and length 30 Meter of type - 2 WP 10 Kgf/Cm2 for first aid hose reel drum, the hose reel shall be properly rolled and connected with inlet and delivery lines all as per IS 444/1987 all as specified and as directed by Engr-in-Charge.
Supply and fix Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in 100mm cast iron water supply mains all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, Dry chemical powder (ABC) type of 5 Kg Capacity cnforming to IS : 2171/13849/14609) incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, CO2 type of 6.5 Kg Capacity cnforming to IS : 22878) incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, water CO2 type of 3 Kg Capacity conforming to IS : 22878, incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, Dry chemical powder (ABC) type of 2 Kg Capacity cnforming to IS : 2171/13849/14609) all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, CO2 type of 2 Kg Capacity cnforming to IS : 22878) all as specified and as directed by Engr-in-Charge.
Supply and fix fire Extinguisher cabniet made of 2mm thick CRCA Sheet, duly coate with fire red colour, front openable doors, provied with acrylic glass on door all for size 1200mm*1200mm*500mm size incluing bottom channels, grouting all as specified and as directed by Engr-in-Charge.
Supply and fix Fire Hydrant cabinet door (Size not More than 2000mm*2000mm) made out of MS sheet of thickness 4mm MS Sheet, suitable for fixing in walls & dually supported with Angle Iron Frames, grouted on wall, including transparent acrylic sheet of 4mm thick and painted with FIRE RED with firemen locking arrangement of size 8"X8",
Supply install, test and commissioning LT Feeder distribution Panel (CPRI Approved) cubical type Indoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded
sleeves. The cubicle shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plateof thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and panel shall be powder coated ( for rust proof)sprayed of approved thickness coated complete as specified and consisting the following : -
(i) Busbar Copper TPN 250 Amps -1No. (ii) Incoming MCCB 4 Pole 100 Amps 415 Volts 35 KA -01 No. (iii) Outgoing MCCB FP Pole 63 Amps 415 Volts 36 kA - 1 Nos. iv) Automatic star delta starter suitable for 50 HP pump. V) MCCB FP 25 Amps 415 Volts 16 kA - 1 Nos. Vi) DOL starter suitable for 5 HP Jockey pump (Frequent ON/OFF Operation) vii) MCB TPN 16 Amps 415 Volts 10 kA - 2 Nos. viii) VAF PF Meter -01 Nos. iX) Indicating Lamps LED Type-03 Nos. (x) One No spare compartments.
INTERNAL ELECTRIFICATION
Supply and fix telephone copper one pair 0.5mm including 20mm dia PVC medium grade concealed conduit complete all as specified and as directed by Engr-in-Charge.
Supply and fix RJ 11 Telephone outlet 4 wire shuttered with and including inner sheet/frame with plate for single module and metal box of size 78 x 78 x 50mm single module complete all as directed by Engr-in-Charge. Cat Part No of Telephone socket is HwAM002, cat part of inner sheet / frame with plate HWAI002 and cat part No of metal box is HWAX002 of Indoasian or equivalent make like Legrand or Anchore etc.
Supply and fix compact flyorescent lamp fitting witrh holder of capacity of 13W DF 3U 6500K with all accessories fixed on walls, on round block of size 80mm dia and 40mm depth open recessed type (2 Nos) and connecting up complete with 23/0.0076 (or equivalent size in mm) flexible three core twisted copper cable all as specified and as directed by Engr-in-Charge.
Supply & Fix Fluorescent tube light fitting, single tube, 1x28W, 230V, Energy Efficient T5, surface mounted,with and including tube 28W, with automatic electronic ballasts, bipin holder, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-Charge.
Supply & fix Street Light luminaries 1 X 28 Watt with asthetically designed sheet aluminium housing and UV stabilized clear acrylic cover,with lamp and accessories and internal connection with 3 core, 1.5 Sqmm PVC insulated copper conductor cble including fixing arrangement comprising of 25 mm dia GI pipe light grade 1.2 mtr long bend at 120 degree fixed to wall with help of 02 Nos clamp made of flat iron 50x6mm and necessary nut bolt and wahser complete including 28W tube lamp.
MAKE: PHILIPS Cat No HSG 120 1 x TL 528 W EBE or Equivalent from Wipro. (If Cat No is revised, equivalent Cat No from Latest Catlauge shall be considered) .
Supply and fix decorative wall mounting Porch luminaire with perforated octagonal shape frame with opal PMMA diffuser complet with lamp and internal connection including bracket all as specified and as directed by Engr-in-Charge. Make - Wipro Cat No WCP 42113/118, 1 x 13 W CFL or equivalent in Bajaj, CG, Havells.
Material and labour for sub main wiring with four runs of single core 10.00 sqmm Flame retardant (FRLS) PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.00 sqmm single core flame retardant PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn through and including PVC concealed Conduit 32 mm dia external with wall thickness not less than 1.8 mm , heavy duty ISI marked, with necessary fixtures/ accessories, fixed on wall/ ceiling etc. all as specified.
Note :All runs of cables, one run of earth wire cable and one run of Conduit and its accessories shall be measured & paid as one length.
Material and labour for sub main wiring with four runs of single core 6.00 sqmm Flame retardant (FRLS) PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.00 sqmm single core flame retardant PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn through and including PVC concealed Conduit 25 mm dia external with wall thickness not less than 1.8 mm , heavy duty ISI marked, with necessary fixtures/ accessories, fixed on wall/ ceiling etc. all as specified.
Note :All runs of cables, one run of earth wire cable and one run of Conduit and its accessories shall be measured & paid as one length.
Material and labour for sub main wiring with two runs of single core 4.00 sqmm Flame retardant (FRLS) PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 sqmm single core flame retardant PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn through and including PVC concealed Conduit 25 mm dia external with wall thickness not less than 1.8 mm , heavy duty ISI marked, with necessary fixtures/ accessories, fixed on wall/ ceiling etc. all as specified.
Note :All runs of cables, one run of earth wire cable and one run of Conduit and its accessories shall be measured & paid as one length.
Material and labour for sub main wiring with two runs of single core 6.00 sqmm Flame retardant(FRLS) PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.00 sqmm single core flame retardant PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn through and including PVC concealed Conduit 20 mm dia external with wall thickness not less than 1.8 mm , heavy duty ISI marked, with necessary fixtures/ accessories, fixed on wall/ ceiling etc. all as specified.
Note :All runs of cables, one run of earth wire cable and one run of Conduit and its accessories shall be measured & paid as one length.
Material and labour for sub main wiring with two runs of single core 4.00 sqmm Flame retardant(FRLS) PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 sqmm single core flame retardant PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn through and including PVC concealed Conduit 20mm dia external with wall thickness not less than 1.8 mm , heavy duty ISI marked, with necessary fixtures/ accessories, fixed on wall/ ceiling etc. all as specified.
Note :All runs of cables, one run of earth wire cable and one run of Conduit and its accessories shall be measured & paid as one length.
Supply & Fix MCB DB TPN, 415 Volts, 04 Way (8+12) vertical double door type power coated sheet steel encloure -1 No (1st Floor -02 & 4th Floor - 02) with following:- (a) Isolator 63 Amp -01No. (b) MCB SPN 40AMP -03 Nos. (c) MCB SPN 20A -03 Nos.
Supply & Fix MCB DB TPN, 415 Volts, 04 Way (8+12) vertical double door type power coated sheet steel encloure -1 No (3rd Floor -01 & 2nd Floor - 01) with following:- (a) Isolator 50 Amp -01No. (b) MCB SPN 26 AMP -03 Nos. (c) MCB SPN 20A -03 Nos.
Supply & Fix MCB DB TPN, 415 Volts, 04 Way (8+12) vertical double door type power coated sheet steel encloure -1 No (Ground Floor -01 & 2nd Floor - 01) with following:- (a) Isolator 40 Amp -01 No. (b) MCB SPN 20 AMP -03 Nos. (c) MCB SPN 16A -03 Nos.
Supply & Fix MCB DB TPN, 415 Volts, 04 Way (8+12) vertical double door type power coated sheet steel encloure -1 No (3rd Floor -01 & 4th Floor - 01) with following:- (a) Isolator 25 Amp -01No. (b) MCB SPN 16 AMP -03 Nos. (c) MCB SPN 10A -03 Nos.
Supply & Fix MCB DB SPN 08 way horizontal double door type power coated sheet steel encloure -1 No (sub DB-01) with following:- (a) MCB SPN 40 Amp - 01 No. (b) MCB SP 10A - 02 Nos. (c) MCB SP 6A - 04 Nos.
Supply & Fix MCB DB SPN 08 way horizontal double door type power coated sheet steel encloure -1 No (sub DB-02) with following:- (a) MCB SPN 26 Amp - 01 No. (b) MCB SP 10A - 02 Nos. (c) MCB SP 6A - 04 Nos.
Supply & Fix MCB DB SPN 08 way horizontal double door type power coated sheet steel encloure -1 No (sub DB-03) with following:- (a) MCB SPN 20 Amp - 01 No. (b) MCB SP 10A - 02 Nos. (c) MCB SP 6A - 04 Nos.
Supply & Fix MCB DB SPN 08 way horizontal double door type power coated sheet steel encloure -1 No (sub DB-04) with following:- (a) MCB SPN 16 Amp - 01 No. (b) MCB SP 10A - 02 Nos. (c) MCB SP 6A - 04 Nos.
Supply & Fix MCB DB SPN 08 way horizontal double door type power coated sheet steel encloure -1 No (sub DB-05) with following:- (a) MCB SP 10A - 01 Nos. (b) MCB SP 6A - 03 Nos.
DG SET
Supply and install, testing and commissioning of silent diesel Engine driven generating set 150 KVA capacity, 3 phase 4 wire, 415 Volt 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures having salient features such as modular bolted construction with fabrication on imported CNC torrent punch machines, nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application / installation, intergrated design thereby facilitating / easy handing installation & shifting of the equipment at site.The design of integral acoustic enclosure should be of the type approved by National physical laboratory as per central pollution control board (CPCB) latest norms/ regulation) with fuel tank, battery and standred accessories and including cost of PCC (1:2:4) type B-1 foundation for (acoustic enclosure also 30 CM above GL) as recommanded by manufacturer, vibration pad, sand cushioning around PCC foundation etc all and tools & spares as provided by manufacturer all as per following specifications:-
(A) ENGINE : Water cooled diesel of at 1500 RPM capacity to match the 150 KVA alternator under NTP conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to BS-5514 /IS-10001/10002 the Engine shall consist of the following :- (i) Fly wheel with starter ring. (ii) Flexible coupling with guard. (iii ) Cooling fan. (iv) Radiator with guard and water pump engine mounted. (v) Dynamo of suitable capacity.(vi) Air cleaner heavy duty dry. (vii) Fuel injection pump. (viii) Radiator fan (Blower type) with guard. (ix) Electronic/A1 class governer. (x) Fuel filter (Mounted). (xi) Lubricating oil filter (mounted). (xii) 24 V self regulating alternator belt driven by engine. (xiii) Exhaust silencer heavy duty residential type
(xiv) Corrosion resistor/ scale inhibitor. (xv) Starter 24 V DC. (xvi) Lubricating oil cooler. (xvii) Lubricating oil pump (Gear type) (xviii) Turbo charger. (xix) Exhaust piping shall be insulated with asbastos rope duly cladded with aluminium sheet. (xx) Insturment panel complete with of the following:- (a) Auto manual starting switch with key. (b) Lubricating oil temperature guage. (c) Lubricating oil pressure guage. (d) Water tempreature guage. (e) Battery charging ammeter. (f) Battery charging indicating lamp. (g) Hour meter with RPM indicator. (h) Sefety control against high temperature of water. (j) Sefety control against low lubricating oil pressure. (k) Over speed stop with double driven adoptor. (B) BRUSH LESS ALTERNATOR (i) Alternator coupled to Engine through a flexible coupling. (ii) Type :- Self excited self regulated with automatic voltage regulator.
(iii) Rating :-150 KVA at 0.8 PF lagging 4 pole hozontal at NTP condition. (iv) Speed :- 1500 RPM (v) System :- 433 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected dip proof. (viii) Ventilation :- Self ventilated (ix) Insulation :- Insulation Class H (C) CONTROL PANEL:- Control panel with aluminium busbar, bottom entry and exit of cable, current transformer, set of control fuse, Multifunctional meter, it should display time and dare, volts, frequency, current KW, KWH, PF, RPM, cumulative Run hours, oil pressure, coolant temp, charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 150 KVA DG set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable an cable connection with lugs/thimbles complete as per latest IS/BS and all as specifed and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) FUEL TANK :- Fuel tank shall be as per manufacturer's design of capacity 8 hours running on full load and mounted as per manufacturer's instructions alongwith level indicator, drain plug, necessary piping and strainer etc. (i) Level indicator (ii) Drain plug (iii) MS class 'C' piping for inlet from pump to tank of engine (iv) Fuel strainer (v) Fuel tank shall be mounted as per manufacturers instructions. Fuel tank capacity shall be sufficient for 8 hrs and mounted as per manufacturer's instructions. (b) SEMI ROTARY PUMP:- Manually operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5.5 mtr flexible hose pipe of suitable size heavy duty for suction of diesel from barrel. (c) BATTERY :- Heavy duty battery one No 12 Volt 120 AH connected to the system with multistranded flexible copper conductor cable complete Make : Exide, Amaron, Standard. (d) BASE PLATE :- Fabricated out of MS channel ISMC of suitable size for fixing of DG set all as specified by the manufacturer.
Supply installation, testing and commissioning of indoor cubical type AMF Panel, free standing floor mounted including of steel structure required for installation on cable trench with base frame AMF panel woking on 440 Volts 3 Phase 50 Hz AC Supply with S/C and adj O/L . E/F relief, UV coil alongwith electrical and mechanical interlocks. It shall be extendable at both ends, withj copper bus bars, fully compartmentalized, dust proof and vermin proof, 2 mm thick CRCA thick steel enclosure, as per the spcifications and having the following details: (a) Copper bus bar 3 phase 4 wire suitable for 600 A cap (b) AC / DC relay (c) AC / DC timer (d) KWH meter (e) AMF Contoller including electrical wiring (f) Power contactor 4 pole 250 Amps-02 Nos (Make - Siemens/Telemechanique) (g) O/L relay for DG set (h) MCCB FP 250 Amps 35 KA - 3 Nos (DG, Mains& Out Going) (make ABB/Siemens) (j) Digital VAFPAF meter for mains and DG set
Supply install, test and commissioning LT Feeder distribution Panel (CPRI Approved) cubical type Indoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plateof thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with
glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and panel shall be powder coated (for rust proof) sprayed of approved thickness coated complete as specified and consisting the following : - (i) Busbar Copper TPN 400 Amps -1 No. (ii) Incoming MCCB 4 Pole 250 Amps 415 Volts 35 KA -01 No. (iii) Outgoing MCCB TP Pole 160 Amps 415 Volts 35 kA - 1 No (Bldg). MCCB TP Pole 100 Amps 415 Volts 35 kA - 1 No. MCCB TP Pole 40 Amps 415 Volts 30 kA - 1 No. (iv) MCB SPN 32 Amps -04 Nos. (v) Indicating Lamps LED Type-03 Nos. (x) One No spare compartments fitted with dinrail for fixing of Make - MCCB-Slemens/ABB.
FIRE ALARM
Supply and lay armoured CAT-5 cable in ground, along the wall/ floor all as specified and as directed Engr-in-Charge.
Supply and fix 1.5 Sqmm 2 Core Copper Conductor multistranded FRLS Armoured cable along ceiling/along the wall/ floor/ trench etc including saddles, screws, junction boxes.
Supply and fix 1.5 Sqmm 4 Core Copper multistranded FRLS Armoured cable ceiling/along the wall/ floor/ ground etc including bens, end caps, junction boxes.
AIR CONDITIONING
Supply, installation, testing and commissioning of Water cooled type chilling packages of Following:- 25 TR Scroll type refrigeration Compressor with R407c refrigerant with Microprocessor panel and suction and Discharge valves, crank case Heater Shell and tube water cooled type Condenser with all accessories Such as safety valves, purging cocks etc. DX chiller along with M. S. ‘C’ class refrigeration piping For hot gas and suction line only With heat exchanger globe valves, Strainers, expansion valves, Solenoid valve antifreeze Thermostat etc. M S stands to install chiller. Microprocessor type panel board with compressor starter. Including all incidental expenses like octroi etc. Chiller should be designed for 11°C/6°C chilled water temperature range and 32°C/36.2°C condenser water range. (2 W + 1 SB) all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of Mono block pump for Chilled water as per technical spec. with TEFC motor, Base frame (2 W + 1 SB) all as specified and as directed by Engr-in-Charge. (a) Water quantity 67 US GPM (Each) (b) Static Head 25 M (c) Impeller Bronze
Supply, installation, testing and commissioning of Mono block pump for Chilled water as per technical spec. with TEFC motor, Base frame (2 W + 1 SB) all as specified and as directed by Engr-in-Charge .(a) Water quantity =100 US GPM (Each),(b) Static Head = 20 M and (c) Impeller = Bronze
Supply, installation, testing and commissioning of 50 TR Induced draft type cooling tower of FRP complete with All Accessories, basin, fittings, fan, fan motor etc. with following tech. data all as specified and as directed by Engr-in-Charge. (a) Water flow/tower = 200 US GPM (Each) (b) Ambient WB Temp. = 83o F (c) Ent. Water Temp. = 97.5o F (d) Basin water Temp. =90o F
Supply, installation, testing and commissioning of uninsulated piping & valves for condenser water as all as specified and as directed by Engr-in-Charge of the following sizes:-
Mild steel 'C' class water pipe 100mm dia
Mild steel 'C' class water pipe 75mm dia
Balancing valve 75mm dia
Butterfly Valve 100mm dia
Butterfly Valve 75mm dia
Butterfly Valve 50mm dia
Non return Valve 75mm dia
Pot strainer 100mm dia
Needle Valve 25mm dia
Pressure Gauge
Thermometer
Hand held digital multi digital scale meter
Supply, installation, testing and commissioning of uninsulated piping & valves for condenser water as all as specified and as directed by Engr-in-Charge of the following sizes:-
Mild steel 'C' class water pipe 65mm dia
Mild steel 'C' class water pipe 75mm dia
Balancing valve 65mm dia
Butterfly Valve 65mm dia
Butterfly Valve 75mm dia
Non return Valve 65mm dia
Pot strainer 75mm dia
Needle Valve 25mm dia
Pressure Gauge
Thermometer
PVC drain piping 50mm dia
Y' Strainer 65mm dia
Purge Valve
3 Way valves motorized with 240 V actuator 65mm dia
Supply, installation, testing and commissioning of uninsulated piping & valves for condenser water as all as specified and as directed by Engr-in-Charge of the following sizes:-
Mild steel 'C' class water pipe 65mm dia (32mm)
Mild steel 'C' class water pipe 75mm dia (38mm)
Balancing valve 65mm dia (32mm)
Butterfly Valve 65mm dia (32mm)
Butterfly Valve 75mm dia (38mm)
Non return Valve 65mm dia (32 mm)
Y' Strainer 65mm dia (32 mm)
Pot strainer 75mm dia (38 mm)
3 Way valves motorized with 240 V actuator 65mm dia (32 mm)
Supply, installation, testing and commissioning of Expansion Tank of Sintex make of 500 litres. Capacity complete with make-up drain and overflow connection and duly insulated with 75 mm thick insulation finished with sand cement plaster data all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of make up water tank FRP 10000 Litre. Complete with inlet and out let pipe connection, float valve and isolation valves data all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of Air Handling Unit as all as specified and as directed by Engr-in-Charge of the following sizes:-
(a) The Unit made out of double skin GI construction As per technical specification. Capacity and size as per AHU details provided. Each AHU will have 6 R Coil, AHU-1, 24 TR / 10000 CFM (CM UNIT)
(b) The Unit made out of double skin GI construction As per technical specification. Capacity and size as per AHU details provided. Each AHU will have 6 R Coil, AHU-2, 26 TR / 13000 CFM (CM UNIT)
Supply, installation, testing and commissioning of G.I. Sheet Metal work as all as specified and as directed by Engr-in-Charge of the following sizes:-
G.I ducting as per specification 24 G
G.I ducting as per specification 22 G
G.I ducting as per specification 18 G
G.I ducting damper of opposed blade type.
S.A diffuser with V.C.D. 450x450
S.A diffuser with V.C.D. 600x600
S.A grill with V.C.D. 600x200
S.A grill with V.C.D. 900x300
S.A Diffuser without V.C.D. 450x450
S.A Diffuser without V.C.D. 600x600
R.A Grill without V.C.D. 1800x200
R.A Grill without V.C.D. 2700x200
R.A Grill without V.C.D. 4500x200
R.A Grill without V.C.D. 2700x300
Fire dampers with fusible link 1000x600
Fire dampers with fusible link 1250x600
F.A louvers with bird screen
Supply, installation, testing and commissioning of insulation as all as specified and as directed by Engr-in-Charge of the following sizes:-
Supply, installation, testing and commissioning of thermal Insulation for Exposed duct with 32 mm with Nitrile Rubber data all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of Acoustic Insulation for supply air duct with 10 mm Nitrile Rubber data all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of thermal Insulation for supply air duct with 13 mm with Nitrile Rubber data all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of thermal Insulation for return air duct with 13 mm with Nitrile Rubber data all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of under deck insulation with 25 mm nitrile rubber with 40-60 KG density data all as specified and as directed by Engr-in-Charge.
Painting Work of Condenser and Chilled water piping with all valves and fittings including Pumps.
Main panel as per SLD and APFC panel as per SLD (Note : For technical specification refer PS Clause No 30.65.4 & 30.66 page 235 & 236)
Lockable Push button for cooling tower.
Supply, installation, testing and commissioning of armoured power cable as all as specified and as directed by Engr-in-Charge of the following sizes:-
3.5 Core x 240 sqmm Aluminium Cable
3.5 Core x 50 sqmm Aluminium Cable
4 Core x 6 sqmm Copper Cable
4 Core x 2.5 sqmm Copper Cable
Laying & Testing only of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of the following sizes in trenches, cable ducts, along wall & Terminating the cables at LT Panels by proper Glands, Lugs etc complete all as specified and as directed by Engr-in-Charge of the following sizes:-
150 Sqmm, 3.5 Core.
120 Sqmm, 3.5 Core.
35 Sqmm, 3.5 Core.
16 Sqmm, 4 Core.
10 Sqmm, 4 Core.
SCHEDULE OF CREDIT AMOUNT Rs. 1405272.01
Vishal Builders
SOOD ASSOCIATES PVT LTD
M/s Gujarat Construction Company
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .