Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹50.8 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹52.2 L+₹1.4 L (2.66%)Rejected-Finance | 2 | Rejected-Finance L2 |
Tender Value
₹49.0 L
EMD Value
₹1.0 L
Closing Date
21 Jan 2024, 3:05 pmClosed
Ex. Engineer (E and M)-V, MCD
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE EXECUTIVE ENGINEER (E and M-V) Room NO - 219,2nd Floor, Dhansa Stand, NEW DELHI-110043
Repairing, Supply, installation, testing and commissioning of pumpsets and other allied equipments at Sector-3 Pkt-16 Dwarka, Adarsh Appartment, Madhu Vihar pumping station under Najafgarh zone, MCD.
2024_SDMC_181181_1
MCD/2023-24/EandM/NGZ/11
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
Najfgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹1.0 L
CE (E and M) MCD, 10th Floor, Dr. SPM Civic Centre
30 Jan 2024
10 Jan 2024
22 Jan 2024
10 Jan 2024
21 Jan 2024
10 Jan 2024
15 Jan 2024
Amount
Providing, laying, testing & commissioning of 'C' class heavy duty MS reducer including Welding, fittings like flanges, nuts bolts, rubber gaskets etc. and painting with two or more coats of synthetic enamel paint of required shade complete as required of diameter 450mm to 300mm.
P&F of C.I. Swing Type Non Return Valve Flanged end as per IS: 5312 having PN 1.6 pressure rating with SS plates vulcanized NBR seal, GI bolts, nuts, washers, rubber gaskets, painting with approved shade etc of 350mm diameter.
P&F of Fully Automatic Star Delta Starter in Steel sheet Enclosure with SPP and overload relay feature i/c connections etc. complete as required 50 hp 3-phase 415V 50 Hz motor.
SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/ mixed/ sewage water having minimum Discharge of 800 m3/hr at Head- 10 Mtrs, RPM - 986 RPM (ind) having suction 300mm and delivery size 350 mm dia. mounted on a common base frame coupled with Min. 50 HP rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. as Casing- C.I., Impeller- C.I., Shaft- 40C8 complete with coupling, coupling guard and foundation bolts.
P&F of Onload changeover switch four pole in existing cubicle panel with advance neutral conforming to IS:13947 (Part-3) including drilling holes in cubicle panel, making connections, etc. complete as required of 250 A
P&F of 4 pole Switch Disconnector in existing Cubical Panel conforming to IEC:60947-3 complete as required of 250 A
P&F of 4 pole Switch Disconnector in existing Cubical Panel conforming to IEC:60947-3 complete as required of 200 A
Repairing of Sluice Valve of diameter 450 mm with following works :- A)Removing of nut bolts of upper dome and removing one by one of bolts and removing of complete sluice valve along with body with the help of lifting arrangement to taking out side ot pump house and making dead by Blank Plate. B)Dismantling of, upper dome, flape, spindle, nut etc. from the main body & taking of each parts one by one. C)Cleaning of all parts like SS spindle, GM nut, flape, body ring etc. by chemical solution, polishing with polish wheel. D)Servicing by opening & cleaning of all parts one by one by chemical solution. E)Replacement of hardware items like nut bolt, rubber packing & gland studs etc. F)Repairing of SS Spindle by remetelling & rethreading etc. as required. G)Assembling flape upper dome SS spindle, G.M nut, Bearings, gland housing and at workshop loading to truck and return back to plant. H) Removing of dead flange of both side line & fixing with new rubber packing, nut bolts etc. at site.
Repairing of Sluice Valve of diameter 350 mm with following works:- A)Removing of nut bolts of upper dome and removing one by one of bolts and removing of complete sluice valve along with body with the help of lifting arrangement to taking out side ot pump house and making dead by Blank Plate. B)Dismantling of, upper dome, flape, spindle, nut etc. from the main body & taking of each parts one by one. C)Cleaning of all parts like SS spindle, GM nut, flape, body ring etc. by chemical solution, polishing with polish wheel. D)Servicing by opening & cleaning of all parts one by one by chemical solution. E)Replacement of hardware items like nut bolt, rubber packing & gland studs etc. F)Repairing of SS Spindle by remetelling & rethreading etc. as required. G)Assembling flape upper dome SS spindle, G.M nut, Bearings, gland housing and at workshop loading to truck and return back to plant. H) Removing of dead flange of both side line & fixing with new rubber packing, nut bolts etc. at site.
P&F of four pole MCCB having rating capacity of 250A and breaking capacity of 36KA(Icu) with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
P&F of four pole MCCB having rating capacity of 200A and breaking capacity of 16KA(Icu) with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 300 mm width X 62.5 mm depth X 2 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required of 100 mm width X 50 mm depth X 1.6 mm thickness
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098 of 3.5 core having size 240 sq. mm.
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098 of 3 core having size 35 sq. mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required upto 35sq.mm. (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 185 Sq mm and Up to 400 sq.mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 3.5X240 sq. mm(62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 3X35 sq. mm(28mm)
Supplying, installation, testing and commissioning of Silent Type DG Sets,AMF Panel, Bus Ducting/ Cables from DG Sets to Essential Panel, Synchronizing Panel where required, DG Set enclosure room sound insulation/ventilation/smoke exhaust as required, Earthing of DG Set system, control cabling, Fuel tank/piping, DG set Exhaust piping/ Exhaust Chimney as per CPCB norms, Civil works connected with DG Sets including Foundation as required of 82.5 KVA
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. All works upto plinth level (For 03 Nos. main pump sets 2*1*.10 = 0.2 cum each )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (85 Kg of Iron Bar required for 1 Cu.m.).
SITC of 150W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt+/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
S.I.T.C LED tube type luminaire 20 watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficiency LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
Supply, Installation, Testing and Commissioning of1200 mm sweep, BEE 5 star rated,ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required.
Supply of 15'' ( 380 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Providing and fixing 4.5 kg Co2 type fire extinguisher sqeeze grip type , trolly wheel as well as wall mounting type complete in all respect with ISI mark i/c fixing arrangement etc as required as per technical specification attached .
Supply,installation,testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtrmtr,suction and delivery 25X25 mm
KAMLESH ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .