Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹20.6 L
EMD Value
₹41,280
Closing Date
18 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
ADDN ALTN OF BUILDING NO P301 AT AFDTS AND ADDITIONAL ALTERATION TO VIP ROOM NO 01 PROVN OF CERTAIN BR WORKS AT CLO COMPLEX PROVN OF DRAIN WITH IRON GRILL GRATING IN FRONT OF MAIN GATE FIXING OF CEMENTED JALI AND SUPPORT POLES OF OFFICERS MESS
2020_MES_354857_3
GE (FBD)/AF-06/2020-2021
Open Tender
Civil Works
Item Rate
180 days
AF STATION FARIDABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹41,280
Yes
20 Jul 2020
10 Jul 2020
20 Jul 2020
10 Jul 2020
18 Jul 2020
11 Jul 2020
75 days
Amount
M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in drain and surface chanel foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Demolition brick work or stone/boulder masonary,built in cement mortar or cement lime mortar including all quions, arches pillars,etc but ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed by the Engineer-in-Charge.
M&L for brickwork using old size bricks Sub class B straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for brickwork with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L for vertical posts and Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
S & F MS steel work in tubular trusses including special shaped washers etc., complete using but ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 with one shop coat of zinc chromate primer paint complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel plates (Plain or chequred) channel square cut or not chequred (ordinary and counter sunk) ferming holes, sithout any attachment for Fe-410-W Gde-E 250 quality 'A'complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel screw bolts(Machine made) with hexagonal or square head at one end and screwed the other end n exc 5 cm long and diametre of neck exc 5 mm but n exc 10 mm dia complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvatume aluminium zince coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvatume aluminium zince coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and as directed by the Engineer-in-Charge.
Providing plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates, 25mm thick, as in floor/sub base and finishing concrete surface fair and even to receive top floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for Dismantling floor, hearth or wall tiling including cement mortor bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
Vitrified Ceramic coloured tiles of approved shade and pattern, 600 x 600 x10-12mm thick, conforming to Group B-IIA of IS-13712, first quality, laid in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge.
M&L for non skid coloured ceramic tiles 7 to 8mm thick 600mm x 600mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge.
M&L for 10mm thick rendering in CM 1:4 as in backing coat to receive tile finish as in skirting and dados complete all as specified and as directed by the Engineer-in-Charge.
M&L for glazed ceramic coloured tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge.
S&F Wood grain printed PVC wall pannel consisting of 5mm thick sheet, fixing at site on wall all as per specified and directed by engineer in charge.
S&F Armstrong/instrulla mineral fibre acoustical ceiling panels of 16 mm thick RH 99 dune (Tegular) over in true in horizontal level false ceiling grid of XL 24mm system manufactured by M/S Armstrong works industries Ltd using hot dipped steel section exposed surface chemically cleaned caping pre-finished in baked polyster paint, wall angle of size 3000X19X19mm used in periphery of the ceiling fixed to wall partition /RCC column / band walls with the help of screws at 600mm C/C , main runner of size3000X24X32mm suspended at 1200mm C/C by using 2mm dia , GI wire hanger securely fixed to the structural soffit of slab by using 6mm anchor fastener at every 1200mm (max) and 1200mm long cross tee of size 24X27mm to be interlocked between in main runner at 600mm long cross tee of size 24X27mm fixed in between 1200mm long cross tee to forming a grid of 600X600mm complete all as per manufacturers complete all as specified and as directed by the Engineer-in-Charge.
Taking down of chowkat with shutter without taking off shutters from the frame exceeding 1.5sqm each but not exceeding 4 sqm complete all as specified and as directed by the Engineer-in-Charge.
Taking down of shutters of any description exceeding 1 sqm each and not exceeding 2 sqm each complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium frames and shutters for doors,windows,ventilators & partitions with one or more rebates including jointing cleat for fixing etc complete all as specified and as directed by the Engineer-in-Charge. NOTE:- Floor spring/door closer ,Glazing& panelling shall be measured and paid separatly
M & L 09 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to timber frame work in cup board shutters/ shelves complete all as specified and as directed by the Engineer-in-Charge.
S & F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sq. M in each pane complete all as specified and as directed by the Engineer-in-Charge.
S & F 200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs 100 mm long Aluminium, anodised, barrel tower bolts of extruded section, fixed in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S & F Continuous (piano) hinges,mild brass, bright finish or electrogalvanised Width 30mm of flaps (when open) in mm complete all as specified and as directed by the Engineer-in-Charge.
M & L 18/19 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to timber frame work in cup board shutters/ shelves complete all as specified and as directed by the Engineer-in-Charge.
S&F butt hinge, medium weight ,cold rolled mild steel 100mm long complete all as specified and as directed by the Engineer-in-Charge.
S&F Door closer hydraulically regulated, designation No 3, aluminium (die cast ) body, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed including taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 2 levers Mortice lock, vertical type, size 100 mm complete all as specified and as directed by the Engineer-in-Charge.
S&F 30mm thick (styles) factory made solid panel PVC door shutters consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width tuck inside with solvent cement for styles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and joined together with solvent cement and fixing in the frame at site all as shown on drawing on page 146 of SSR Part-II 2004 including taking down the old PVC door shutters complete all as specified and as directed by the Engineer-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel tube & fixed in position as per manufacturer's instruction all as specified, as shown on drawing on page No 150 of SSR Part-II 2004 including taking down the old PVC door frame complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel pressed handles, 150 mm oval type, stove enameled black complete all as specified and as directed by the Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position complete all as specified and as directed by the Engineer-in-Charge and directedin SSR Pt I
S&F for 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 20mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore galvanized steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore galvanized steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge.
S & F in Repairs Vitreous Ware wash down water closet pan (Pedestal pattern), white (ETWC) with plastic water closet seat, black closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by the Engineer-in-Charge.
s& f Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP Pillar tap, brackets,waste coupling , PVC Connection, cutting and pinning in ends of brackets or erecting stand fixed in repairs complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC flushing cistern, low level,10 litres capacity , valveless, syphonic action type, white, with inlet, ball valve, float, handle, flush pipe of polythlene of low or high density or PVC, 32 mm dia and taking down of existing old cistern complete all as specified and as directed by the Engineer-in-Charge.
S&F for flow square hand shower with 2.5 mtr stainless steel flexible tube with hook (make : jaquar or equivelent) complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated fancy type foam flow as approved by engr-in-charge 2 in 1 bib tap Complete of Make - Jaguar (Product code No 539) or equivalent in M/s Parry ware/M/s Johnson including taking down the unserviceable one all as specified and directed. complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Stop/angle valve,15mm bore, fancy type, brass chromium plated, concealed type, with long shank and cup, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated /PVC health foaset along with 1.5m PVC tube & swinging wall hook fancy type as approved by engr-in-charge Complete of Make - Jaguar or equivalent in M/s Parry ware/M/s Johnson including taking down the unserviceable one complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC connection, 15mm size, with PTMT nuts, of length 450 mm long including taking down of existing old pipe complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Towel Rail,20mm dia brass chromium plated. D type, 600 mm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with mild steel chromium plated bracket guard and railing 60cm long complete all as specified and as directed by the Engineer-in-Charge.. Make- Jaquar or equivalent in (2) Hindware (3) ZIM
S & F in repair CP Toilet paper holder of complete all as specified and directed by Egnr-in-Charge Make-Jaquar or equivalent in (2) Hindware (3) ZIM
M&L granite tile 18mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white/coloured cement with admixture of pigment to match the shade of granite store including cutting and polishing etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour forMachine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by the Engineer-in-Charge.complete all as specified and directed.
S & F in repair CP towel rack 600mm size with lower hanger complete all as specified and directed by Egnr-in-Charge Make-(1)Jaquar or equivalent in (2) Hindware
M&L PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement including all necessary concrete work and connecting jobs for making good the area complete all as specified and as directed by the Engineer-in-Charge.
PVC (SWR) pipes, 75 mm bore, single socketed, in any length, with rubber ring joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge..
S&F PVC (SWR) bends any radius, 75mm bore, fitted with oval access door complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) junction single,(Single T) equal or unequal, 75mm bore, fitted with oval access door complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 for complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparing new surfaces of walls, distempering 2 coats with oil emulsion distemper white or tinted over one coat of wall care putty complete all as specified and as directed by the Engineer-in-Charge
M&L for washing down and stopping old distempered walls including cornices, pillasters etc, preparing the surfaces and applying one coat of oil bound distemper complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 68 above but on ceiling surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for washing down and stopping old cement base painted wall surfaces including cornices, pillasters etc, preparing the surfaces and applying one coat of cement based paint complete all as specified & as directed complete all as specified and as directed by the Engineer-in-Charge.
Complete removal of existing treatment including preparation of surfaces and applying two coats of weather proof emulsion (Apex Ultima) of electric blue or white colour over a coat of exterior wall primer in (projections of column/wall/edges of chajja, roofs and other narrow locations in buildings upto ground plus three floor) complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as in plinth protection or path including necessary formwork complete all as specified and as directed by the Engineer-in-Charge
S&F mild steel pressed handles, 150 mm oval type, stove enameled black complete all as specified and as directed by the Engineer-in-Charge
Demolition of plain cement concrete in ground floor incl tiles and pavings n. exc 15 cm thickness below and above ground level complete all as specified and as directed by the Engineer-in-Charge
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr deep for foundation etc or for shafts wells, cess pits, manholes, pier holes etc n exc 10 sqm on plan and getting out in Hard/dense soils complete all as specified and as directed by Engr-in-charge
M/L M-25 using 20mm graded stone aggregate in foundations, footing, plinth beams, columns and slab, complete (reinforcement to be measured separately) complete all as specified and as directed by the Engineer-in-Charge
Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick complete all as specified and as directed by the Engineer-in-Charge
Form work to sides of concrete fdns, footings, bases of columns, raft and raft beams, sides and soffits of fdn and plinth beams and similar works complete all as specified and as directed by the Engineer-in-Charge
Form work to sides of pillers, columns, struts, parts etc complete all as specified and as directed by the Engineer-in-Charge
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with dips icl, anchoring and welding at places as directed quilety conforming to IS complete all as specified and directed by Engr in Charge.
As per item No 80 above but 5mm dia and over upto incl 10mm dia in stirrups, spacers and binders complete all as specified and as directed by the Engineer-in-Charge
M & L PCC 1:2:4 type B-1 using 20mm graeded stone aggregates as in floor 40mm thick finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M & L 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregates in sub base complete all as specified and as directed by the Engineer-in-Charge
M & L glazed coloured joint free virified ceramic tiles to10 mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering on stone masonry surfaces or surfaces other than fair faces of brick work in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge. Make - Somani, Kajaria, Johnson or equivalent
M&L for 10mm thick cement plaster on brick or concrete surfaces, as in ceiling / facia / chajja etc. in cement mortar 1:3 finished even and smooth without using extra cement,complete all as specified and as directed by the Engineer-in-Charge
Preparing new plastered surfaces and applying Two coats of weather proof paint over a coat of alkali resistant priming paint complete all as specified and as directed by the Engineer-in-Charge
Preparing new surfaces of walls and ceiling and applying two coats of plastic emmulsion over a coat of primer over wall care putty complete all as specified and as directed by the Engineer-in-Charge
Complete removal of existing treatement of walls and ceiling and applying two coats of plastic emmulsion over a coat of primer over wall care putty complete all as specified and as directed by the Engineer-in-Charge
Epoxy treatment for bonding new or old Brick /concrete surfaces with applying chemical fosroc and Nitto Bond AR complete all as specified and as directed by the Engineer-in-Charge and as per manufacturers instructions
M&L 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed by the Engineer-in-Charge
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings Such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and as directed by the Engineer-in-Charge
Taking down carefully copper/aluminium point wring 4.0 Sqmm removing material to store for keeping in safe custody for re-use or as credit of complete all as specified and as directed by the Engineer-in-Charge
Taking down carefully aluminum two core sub main wiring of sizes 6 Sqmm /4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and as directed by the Engineer-in-Charge
Taking down MCB DB from existing building and removing service connection complete all as specified and as directed by the Engineer-in-Charge
M&L point wiring with 1.5 Sqmm (Nominal area) PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper concuctor in and including PVC concealed conduit and conduit accessories along with continuous earth wire 1.5 Sqmm PVC insulated, unsheathed stranded copper conductor cable and connected to common earth dolly, with and including complete with all accessories for one light point/Fan point controlled by one ,one way switch complete all as specified and as directed by the Engineer-in-Charge
All as mentioned in item No 95 here in above but one light point controlled by 2 way switches with cable 1.5 Sqmm complete all as specified and as directed by the Engineer-in-Charge
All as per Item No 95 mentioned here-in- before but on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and as directed by the Engineer-in-Charge
All as per item No 95 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 95 mentioned here-in- before but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and as directed by the Engineer-in-Charge
All as per item No 95 mentioned here-in- before but for Single pole and neutral enclosure with 4.0 sq mm PVC insulated and sheathed copper conductor with 4.0 sq mm PVC insulated copper conductor single core for continuous earthing complete complete all as specified and as directed by the Engineer-in-Charge
S&F Piano switch , flush button type single pole one way 5 Amp complete all as specified and as directed by the Engineer-in-Charge
S&F two way switch piano push, flush type 5/6 Amps complete all as specified and as directed by the Engineer-in-Charge
S&F socket outlet, in repairs, flush type 2 in 1, 2 pin and 3 pin 5 Amp multipurpose complete all as specified and as directed by the Engineer-in-Charge
S&F socket outlet, in repairs, flush type 2 in 1, 3 pin and 5 pin 15 Amp multipurpose complete all as specified and as directed by the Engineer-in-Charge
S&F stepped type electronic fan regulator socket type 5 step, 240 V AC , flush type on the existing phenolic laminated sheet etc complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts 8 way with neutral bus bar 200 Amp rated double door type regal grey all as Specified and Directed by Engr-In-Charge.
S&F in repairs,MCB SP 5-32 Amps,"B" series 240 Volts complete all as specified and as directed by the Engineer-in-Charge
S & F in repairs,MCB SPN 32 Amps,"B" series 240 Volts complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm three terminals complete all as specified and as directed by the Engineer-in-Charge
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm in and incl. duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly all complete all as specified and directed by Engr-in-charge.(Flexible Copper Wire Used In FRLS)
S&F lamp batten holder, in repairs, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by the Engineer-in-Charge
S&F LED tube light batten,20W LED,6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-charge
S&F in repairs,LED tube light batten,12W LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-charge
S&F in repair energy efficient LED building secruity lights 1x30W with lens, PDC aluminium body and clear glass LED lens for wide beams distributions efficay >100 Lm/W, CCT 5700K, IP-65 complete with bracket nut bolts and washers suitable for fitted in building complete all as specified and as directed by the Engineer-in-Charge
M & L in repairs earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm dia size means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and as directed by the Engineer-in-Charge
S&F modular switches 1 way, 6 Amp, 1 module complete all as specified and as directed by the Engineer-in-Charge
S&F socket modular 6A-2/3 pin combined with 2 module complete all as specified and as directed by the Engineer-in-Charge
S&F switch modular 1 way, 16 Amp, 1 module complete all as specified and as directed by the Engineer-in-Charge
S&F socket modular 16A-2/3 pin combined with 2 module complete all as specified and as directed by the Engineer-in-Charge
S&F Switch modular Bell Push 1 Way,6 Amp complete all as specified and as directed by the Engineer-in-Charge
S&F Call Bell Ding Dong multi musicType complete all as specified and as directed by the Engineer-in-Charge
S&F modular fan regulator, stepped type 120W, 2 module complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs,sheet metal enclosure for MCCB DB's TPN 4 Way, 415 volts with neutral bus bar 200 Amp rated double door including MCCB 63 Amp, 10 KA, incomming, and suitable for MCB SPN/SP outgoing complete all as specified and directed. all as Specified and Directed by Engr-In-Charge.Make- .Make: Havells/Standrad/Anchor
S&F in repairs,MCB SP 5-32 Amps,"C" series 240 Volts complete all as specified and as directed by the Engineer-in-Charge.Make: Havells/Standrad/Anchor
S & F in repairs,MCB SPN 40 Amps,"C" series 240 Volts complete all as specified and as directed by the Engineer-in-Charge Make: Havells/Standrad/Anchor
S&F in repairs LED light fitting,18 Watt,6000K (4 ft.),Wall mounted,diffused batten type, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver,life of 30000 burning hours,No UV and IR radiations connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size for connecting with ceiling rose all as specified and directed by Engr-in-charge,
S&F recessed mounting edgelit slim LED panel light 6W round powder coated PDC aluminium body and high quality LGP & PMMA diffuser with seperate driver mounted square fixture in white finish with and separate electronic driver,life of 30000 burning hours,No UV and IR radiations suitable for low depth ceiling complete with all accessories, internally pre-wired including three core twisted flexible copper conductor of suitable size for connecting with ceiling rose all as specified and directed by Engr-in-charge
S&F exhaust fan 300mm sweep, metal body heavy duty with louvers complete with making suitable hole and fixing accessories complete all as specified and as directed by the Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in any position not otherwise specifically provived complete all as specified and as directed by the Engineer-in-Charge
M&L PCC in 1:2:4 type B2 using 40 mm graded stone aggregate as in foundation/drains and surface channels etc complete all as specified and as directed by the Engineer-in-Charge
M&L for reinforced cement concrete ( design mix) M-30 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete all as specified and directed by engineer-in-charge
S&F mild steel framed work such asgrills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders: framed balusters, wall ways, railings, frame work of water tanks and similar work confirming to to Fe.290.Gde-E-165 all as specified and directed by engineer-in-charge
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm all as specified and directed by engineer-in-charge
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point all as specified and directed by engineer-in-charge
S & F Expanded steel metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed to wood or steel members work weight exceeding 4 Kg per Sq. M complete all as specified and directed by engineer-in-charge
Material and labour for PCC 1:2:4, Type B-0 [using 12.5 mm graded aggregate] in copings ,benching complete all as specified and as directed by Engineer - in - Charge.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4 louvres and jallies, 25mm thick (mea sured solid outer to outer edge), including all mould- ings but excluding frame (Pre cast frame shall be measured separately and paid complete all as specified and as directed by Engineer - in - Charge. (Note:- Design of jali will be approved by GE)
S & F precast cement concrete type B0 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4 fancy designed boundary Jali Pillar of minimum cross section area of (10x10)Sqcm of approved design complete all as specified and as directed by Engineer - in - Charge. (Note:- Design of jali will be approved by GE)
M&L for preparation of new cemented surfaces and applying two coats of weather proof emulsion (Apex Ultima) of approved colour over a coat of exterior wall primer in (projections of column/wall/edges of chajja, roofs and other narrow locations in buildings upto ground plus three floor) complete all as specified and as directed by the Engineer-in-Charge
Providing plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregates, 100mm thick, as in sub baseto receive top floor finishes complete all as specified and as directed by the Engineer-in-Charge
M&L for chequered and coloured cement concrete car parking tiles 20 to 25mm thick (square/ rectangular) area of each tile exc 0.09 sqm but n.exc 0.25 sqm in car parking floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge (Note- colour and design will be approved by GE)
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished ) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment ot match with shade of granite including 15mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for pre-cast reinforcement cement concrete (1:2:4) Type B-1, using 20 mm graded stone aggregate as in cover slab for manholes etc.and set in cm 1:6 complete all as specified and as directed by the Engineer-in-Charge
S & F in repairs Sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge
S&F for 50mm dia High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm complete all as specified and as directed by the Engineer-in-Charge
M&L for cutting holes n.exc. 150Sqcm into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed by the Engineer-in-Charge
laxmi enterprises
H.B. Traders
airstack india
M/S Satyam Associates
sunil traders
G M CONSTRUCTION COMPANY
M/S Davinder Kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .