| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 CrAdmitted-Finance | ₹11.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹12.2 CrAdmitted-Finance | ₹12.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹13.1 CrAdmitted-Finance | ₹13.1 Cr | L3 | Admitted-Finance |
| 4 | L4₹13.1 CrAdmitted-Finance | ₹13.1 Cr | L4 | Admitted-Finance |
| 5 | L5₹14.4 CrAdmitted-Finance | ₹14.4 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Sumit Gupta L2 | TBA INFRASTRUCTURE PVT LTD L5 | M/S CONSTRUCTION ENGINEERS L4 | Sanjiv Kumar Sharma L3 | KAPAHI CONTRACTS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 in all kind of soil | 28 | Sqm | 3,333 ₹93,324 | 2,000 ₹56,000 | 1,500 ₹42,000 | 500 ₹14,000 | 5,000 ₹1.4 L |
| 2.00 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in all kind of soil | 8,780 | Cum | 303 ₹26.6 L | 170 ₹14.9 L | 150 ₹13.2 L | 150 ₹13.2 L | 150 ₹13.2 L |
| 2.10 | Ordinary rock | 300 | Cum | 333 ₹99,900 | 350 ₹1.1 L | 300 ₹90,000 | 250 ₹75,000 | 250 ₹75,000 |
| 2.20 | Hard rock (Required Blasting prohibited) | 150 | Cum | 666 ₹99,900 | 500 ₹75,000 | 500 ₹75,000 | 350 ₹52,500 | 350 ₹52,500 |
| 3.00 | Extra for every additional lift of 1.5 M or part therefore in all kinds of soil. | 1,497 | Cum | 99 ₹1.5 L | 30 ₹44,910 | 80 ₹1.2 L | 20 ₹29,940 | 50 ₹74,850 |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed. | 435 | Cum | 4,005 ₹17.4 L | 4,200 ₹18.3 L | 3,600 ₹15.7 L | 4,000 ₹17.4 L | 2,500 ₹10.9 L |
| 5.00 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work upto plinth level. | 1,775 | Cum | 5,454 ₹96.8 L | 6,700 ₹1.2 Cr | 6,800 ₹1.2 Cr | 7,000 ₹1.2 Cr | 7,000 ₹1.2 Cr |
| 6.00 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work above plinth level upto floor V level. | 1,255 | Cum | 6,999 ₹87.8 L | 7,200 ₹90.4 L | 7,700 ₹96.6 L | 8,000 ₹1.0 Cr | 7,000 ₹87.8 L |
| 7.00 | Providing and laying in position 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level | 45 | Cum | 6,066 ₹2.7 L | 6,500 ₹2.9 L | 6,800 ₹3.1 L | 6,000 ₹2.7 L | 7,500 ₹3.4 L |
| 8.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) | 26 | Cum | 6,066 ₹1.6 L | 6,500 ₹1.7 L | 7,800 ₹2.0 L | 8,500 ₹2.2 L | 7,500 ₹1.9 L |
Tender Value
₹15.4 Cr
Closing Date
14 Dec 2021, 6:00 pmClosed
XEN PWD Udhampur
Udhampur
Pl. refer to BOQ
2021_PWDJK_150067_1
e-NIT No. 126 of 2021-22 dated 25.11.2021
Open Tender
Civil Works
720 days
Majalta Udhampur
Pl. refer to NIT/SBD
2 documents required · 2 mandatory
₹6,000
XEN PWD Udhampur
Exempted
Jammu
28 Dec 2021
25 Nov 2021
15 Dec 2021
26 Nov 2021
14 Dec 2021
26 Nov 2021
6 Dec 2021
Amount
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 in all kind of soil
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in all kind of soil
Ordinary rock
Hard rock (Required Blasting prohibited)
Extra for every additional lift of 1.5 M or part therefore in all kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work upto plinth level.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge All work above plinth level upto floor V level.
Providing and laying in position 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).with 20% boulder
Providing and laying DPC 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and curing complete.
Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 fine sand).
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement : 6 fine sand).
Extra for brick work in super structure above plinth level upto floor V-level.
Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand).
Extra for half brick work in super structure above plinth level upto floor V-level.
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.
6mm thick cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand).
12mm cement plaster of mix 1:6 (1 cement : 6 fine sand).
15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand).
15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 6 fine sand).
15mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating cost of neat cement on the rough side of single or half brick wall.
Extra for plastering exterior walls of the height more than 10 Mtrs from ground level for every additional height of 3 Mtrs or part thereof.
Making of grove 12mm x 10mm between brick and RCC.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size below flooring, retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M.
Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete.
Dumping stones including cost of stones in horizontal or level.
Add or deduct for plaster drip coarse / groove in plastered surface of moulding to RCC projections.
Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed.
Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Centering and shuttering including strutting, propping etc. and removal of form work for :-
Foundations, footings, bases of columns.
Columns, pillars, piers.
Lintels, beams, plinth beams.
Suspended floors, roofs, landings and access platforms.
Edges of slabs and breaks in floors and walls upto 20cm wide.
Edges of slabs and breaks in floors and walls above 20cm wide.
Stairs (excluding landings) except spiral stair cases.
Wall (any thickness) including attached pilasters, buttresses, plinth and string courses fillets etc.
Weather shades, chajjas, corbels etc. including edges.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 mtr. of part thereof (Plan area to be measured). Suspended floors, roofs landing, beams and balconies (Plan area to be measured).
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- charge with average thickness of 120mm and minimum thickness at khurra as 65 mm.
Providing and laying water proofing treatment (Make Armocreate of SWC Chryso France) to vertical and horizontal surface of depressed portions of W.C., kitchen and the consisting of (i) Ist course of applying cement slurry @ 4.4 kg /sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding of junctions of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions including rounding of junctions of vertical and horizontal surface. (iii) III course of applying blown or / residual bitumen applied hot at 1.7 kg per sqm of area. (iv) Ivth course of 400 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm.
Providing and laying glossy finished vitrified ULTRA CHARGE TILES PRM QUALITY floor tiles of 60x60cm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make of Somany, NITCO and Kajaria make in colours and shade Dacia Series, Crown series, Nuvaro series and Luciano series with the combination of light and dark color laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with matching Epoxy OR Grouts of Make Somany,Nitco, Kajaria etc. complete.
Providing and laying glossy finished vitrified ULTRA CHARGE TILES PRM QUALITY floor tiles of 60cmx120cm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make of Somany, NITCO and Kajaria make in colours and shade In Colpi white, magnus Ivory,Magnus Slate grey, magnus white, Oynx Pearl, Monza red, Monza Green, Statuario pearl with the combination of light and dark color laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with matching Epoxy OR Grouts of Make Somany,Nitco, Kajaria etc. complete.
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand).
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying 16mm thick Granite of any colour and shape (area of slab upto 0.5 Sqm) gang saw cut mirror polished (pre moulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Extra for providing edge moulding to 18mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.
Extra for providing opening of required size and shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble / stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Providing and fixing Ceramic glazed floor tiles (Anti skid) 600x600mm of PRM Quality conforming to ISO : 13006 of NITCO, SOMANY, KAJARIA with Water absorption <6% of color and shades In Aegis series, Champion series, Fence series IN SLIP SHIELD laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete.
Providing and fixing PRM Quality Ceramic Glazed wall tiles of Size 300x600 mm conforming to IS : 15622 of minimum thickness 7mm with water absorption < 20% of approved make like NITCO,SOMANY, KAJARIA in all colour and shades in Sierra series, Sterno series, Vivo series, Diano series, Perlino series, Aleta series, Arian series, Edric series, Elemento series, Julian series over 12mm thick bed of cement mortar 1:3 (1cement : 3coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing Ceramic glazed Tiles 600x600mm of PRM Quality conforming to ISO : 13006 of NITCO, SOMANY, KAJARIA with Water absorption <6% of color and shades In Aegis series, Champion series, Fence series in V.C. SHIELD laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) sal wood
Providing & fixing glazed shutters 35mm thick for doors, windows and clear story windows using 10Kg/Sqm (4mm thick) glass panes including stainless steel but hinges of size 75mm x 62mm x 2mm of make Kitch, Arch, Blum with necessary stainless screws in second class deodar wood.
Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauge of average width for aperture 1.4mm in both direction with wire of dia 0.63mm for doors, windows and clerestory windows with hinges and necessary screws in second class deodar wood.
Providing and fixing of glass panes weighing 12.50 kg/sqm (5.0mm thick) with deodar wood fillets.
Providing and fixing ISI marked 35mm flush door shutters conforming ti IS: 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both face of shutters including ISI marked M.S pressed bright finished butt hinges with necessary screws of required size
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (glazing and panelling to be paid for separately).
For fixed portion using Powder coated aluminium (minimum thickness of powder coated 50 microns).
For shutters of doors, windows and ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coated 50 microns).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc. with PVC / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item). With glass panes of 5.50 mm thickness (weight not less than 13.75 kg/sqm).
Providing and fixing 12mm thick prelaminated three layer medium density (exterior grade) particle board Grade-I, Type-II conforming to IS : 12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows shutters and partition frames with C.P brass / stainless screws etc. compete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS:6315 marked for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge with brass cover plate.
Providing and fixing structural glazing on required portion of the building with aluminium section (12 gauze using 5.5mm toughen glass with all necessary fittings) as per direction of Engineer-in-charge.
Providing and fixing aluminium tower bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing aluminium handles ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter.
Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :-
Coupler 110mm.
Single tee with door 110 x 110 x 110mm.
Bend 87.5* 110mm.
Providing and fixing aluminium sliding door bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 300x16mm.
Providing and fixing oxidized M.S. hasp and staple (Safety type) conforming to IS : 363 with necessary screws etc. complete.
Providing 40x5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper.
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on xposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600x1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminum frame work shall be paid separately).
Applying priming coat with ready mixed pink or grey of primer of approved brand and manufacture on wood work (hard and soft wood).
Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work (Wood work).
Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade (two or more coats) on new steel work.
P/F stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc, including welded, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,
Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approve steel primer all complete (fixed to openings/wooden frames with rawl plugs, screws etc.).
Steel work welded in built-up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladders, railings, brackets, gates and similar work.
Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacture,over the plasterted wall surface to prepare the surface even and smooth complete
White washing with lime to give an even shade. New work (three or more coats)
Finishing wall with acrylic smooth exterior paint of required shade on New work (two or more coats applied @ 1.67 litre/10 sqm over and including base coat of water proofing cement paint applied @ 2.20kg/10sqm)
Finishing walls with textured exterior paint of required shade on New work (two or more coats Rustic Regular of any colour as per Engg. incharge) over and including base coat of exterior primer applied @ 3.00kg/10sqm.
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
Maintaining 50mm joint right from foundation to top and allowing its free moment throughout the life span of structure "Providing/Supply of Dura Board HD 100, 50mm, Premounded Compressible filler Board in Black colour manufactured by the Supreme industries Ltd. or equivalent, conforming to MORTH specifications (clause 1015), having minimum density 95 kg/cum, non staining with less than 1% water absorption and compression recovery 93% minimum as per specifications" in the joint through and through (foundation to top) in brick masonary, columns and beams.
Sealing of joint 50mm. Clean the joint both the side and apply Master Brace ADH 2200 adhesive throughly on the clean surface along the joint with spatula and thickness should be 1mm -2mm. Place the Master Seal 1930 10mm on the ADH 2200 on the both sides keeping the centre totally for free movement.
Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
Stone aggregate below 40mm size for an average lead of 20 Kms.
Stone aggregate Above 40mm size for an average lead of 20 Kms.
Stone for an average lead of 10 Kms.
Sand for an average lead of 35 Kms .
Bricks for an average lead of 20 Kms .
Brick bats (size 25mm to 115mm) for an average lead of 20 Kms.
Providing, laying and making kerb channel 30cm wide and 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth etc. complete as per direction of Engineer-incharge for paver tiles
Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).Size 300x250x100mm
Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete Non-pressure NP-3 class (Medium duty) R.C.C. pipes 1000 mm dia. R.C.C. pipe (laying by manual/mechanical means)
Plumbing
SUB HEAD - I : SANITARY FIXTURES
Providing & fixing of white vitreous China pedestial type water closet (European Type) with cistern (A/PHAS-100 Cat No. 201100+Cat No. 21054 / Kerovit model No. 112 and flush tank model no. 1001) with CP bolts, nuts, CI chair hanging arrangements, bakelite seat & cover with CP hinges & rubber buffers, CP brass screw, washer with all accessories with WC connector with Rubber Lip / Buffer and side gap filled with silicon sealant wherever required. Including brass / SS screws and washer complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-in-charge.
Providing & fixing of white vitreous china under counter oval wash basin/circular basin (Hindware 10080 / Kerovit model No. 206 & 207) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge.
Providing & fixing of white vitreous china wash basin with pedestal (Hindware Cat No. 1008 + Ped Cat No. 11003 / Kerovit model No. 234 Ped Model no. 305) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge.
Providing and fixing CP single liver extended basin mixer (height 85mm) without Popup waste system with 450mm long Braided Hoses and brass nuts with all fittings and accessories as per direction of Engineer-in-charge (Jaquar FUS 290238).
Providing & fixing white vitreous china flat back urinal with automatic flushing systems (Hindware 60021 / Kerovit model No. 505) comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning including necessary wall cutting / chasing and making good, as required for urinal flushing complete as mentioned above as per direction of Engineer-Incharge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610 x 460 mm bowl depth 200 mm (Pantry)
Kitchen sink without drain board 610 x 460mm bowl depth 200mm (Pantry).
Providing and fixing, testing and commissioning of C.P. brass single hole sink mixer with CP wall flange, swinging spout complete as required and making good as per direction of Engineer-in-Charge (Jaquar Cat No. CQT-23167D)
Providing & fixing C.P. hand spray with lever control (health faucet) (Jaquar Cat. No. ALDCHR-565 / Kerovit make KA580001) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore (Make Jaquar CQT 23059 / Kerovit make Cat No. KB 1511003).
Providing & fixing C.P. brass robe hook (Jaquar Cat No. ACN 1191N) or approved equivalent) fixed to wall/door with plastic rawl plugs and C.P brass screws including cutting and making good the walls wherever required as per direction of Engineer-Incharge.
Providing & fixing recessed liquid soap dispenser (Jaquar Cat No. ACN 1135N) as per direction of Engineer-Incharge.
P/F of Soap Dish Holder with all fittings as per direction of Engineer-in-charge (Jaquar Cat No. ACN 113 N).
Providing and fixing of Tumbler Holder with all fittings as per direction of Engineer-in-charge (Jaquar Cat ACN 114 N).
Providing and fixing Bottle Trap (Jaquar Cat No. ALD. 769L) and other ancillary fittings. Cutting and making good the walls wherever required compete as per directions of Engineer-Incharge.
Providing and fixing complete set of sanitary fixtures for handicapped toilets, Hindware Cat. no. 70002) comprising of EWC - P , Cistern, Seat Cover, Twin Flush Fittings, Wash Basin 450x300, Half pedestal, 1 faucet with spatula lever, 1 hinged rail and 2 grab bars, including cutting and making good the walls and floors wherever required complete as per directions of Engineer in charge.
Providing and fixing 6mm copper backed float glass mirror MODI / SAINT-GOBAIN including 6mm thick BWR type ply board, 40mm stainless steel channel plugged to wall, hard wood treated with two coats of wood preservative, etc. all complete as specified and shown in drawing complete to the satisfaction of Engineer in charge.
P/F brass towel ring round with round flenge of approved make complete with all fittings (Jaquar Cat No. CAN 11021 BN / Kerovit make Cat No. KA 930004).
Providing and fixing of glass shelf 600m long with all C.P fittings of approved quality complete item (Jaquar Cat No. ACN 11071 N).
Providing and fixing toilet paper holder with all fittings Jaquar Contienal ACN 1153 N.
Providing and fixing 15 mm dia. C.P. brass bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (Short Body) (Make Jaquar Cat No. CQT-23047)
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (15 mm dia.) (Make Jaquar Cat No. CON-107KN / Kerovit make Cat No. KB 1511004 CP)
P/F of regular body concealed stop cock suitable for 15mm pipe line with protection cap (Jaquar Cat No. ALD 083 / Kerovit make Cat No. KB 111030 CP and exposed part Cat No. KB 1511032) with exposed part angular stop cock with flange FUS 29.53.
Sub Head- II-Water Supply
Internal work:- Exposed on wall Providing and fixing of Polyethylene/Aluminum/Polyethylene (PE-AL-PE) composite Pipes as per IAPMO IGC-INDIA 308, UMC-1 TM certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer's name or trade mark including all relevant DZR brass fittings as Female Elbows/Tees, MTC/FTC and Engineering plastic fittings with internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplers, Clamps at one meter spacing, with PAP valves and brass tank Nipples etc. Including testing of lines and joints as per Engineer in charge. Make Kitec, Maithilee and Vista.
2532 (32mm OD) pipe
3240 (32mm OD) pipe
Conceal Inside the walls:- Providing and fixing of Polyethylene/Aluminum/Polyethylene (PE-AL-PE) composite Pipes as per IAPMO IGC-INDIA 308, UMC-1 TM certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer's name or trade mark including all relevant DZR brass fittings as Female Elbows/Tees, MTC/FTC and Engineering plastic fittings with internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplers, Clamps at one meter spacing, with PAP valves etc. Make Kitec, Maithilee and Vista. Concealed, installation including cutting chases and making good in the wall etc, Complete in all respect. 1620 (20mm OD) pipe.
1620 (20mm OD) pipe
2025 (25mm OD) pipe
External work:- Providing and fixing of Polyethylene/Aluminum/Polyethylene (PE-AL-PE) composite Pipes as per IAPMO IGC-INDIA 308, UMC-1 TM certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer's name or trade mark including all relevant DZR brass fittings as Female Elbows/Tees, MTC/FTC and Engineering plastic fittings with internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplers, Connectors, with PAP valves etc. Trenching, re filling and testing etc. Complete as per Engineer In Charge. Make Kitec, Maithilee and Vista.
1620 (20mm OD) pipe
2025 (25mm OD) pipe
2532 (32mm OD) pipe
3240 (32mm OD) pipe
SUB HEAD - III : DRAINAGE SYSTEM
Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed.
Providing at site of works and lowering, laying and jointing HDPE pipes and required specials of outer diameters conforming to IS : 14333-1996 and bearing ISI mark in prepared trenches to required grade and level icluding cost of jointing materials, chemicals, labour required for handling and making joints etc. including hydraulic testing of pipes, refilling of trenches etc. complete note :- Water for initial testing will be made available free by MIDC if possible. For subsequent fills necessitated on account of rectifications water will be charged at the prevailing industrial water rates in respective industrial area.
110 mm dia 6 Kg/cm2
160 mm dia 6 Kg/cm2
200 mm dia 6 Kg/cm2
Construction brick measonery man hole in cement motor 1:4 (1 cement: 4 Coarse Sand) R.C.C top slab with 1:2:4 mix (1 cement: 2 Coarse Sand: 4 graded stone aggrigate 20 mm nominal size) foundation concrete aggrigate 40 mm Nominal Size, in side palstering 12mm thick with cement mortor 1:3 (1 cement:3 Coarse sand) finshed with floating coat near cement and making channels in cement concrete 1:2:4 (1 cement:2 Coarse snad:4 graded stone aggirgate 20mm nominal size) finished with floating coat of neat cement complete as per standard design. inside size 90cmx80cm and 45cm deep including cast iron cover with frame (light duty) 455x610mm internal dimensionals. total wt. of cover and frame to be not less than 38kg (wt. of cover 33kg and wt.of frame 15kg) with F.P.S bricks of class designation 75 (crush stone aggrigate)
Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. (With F.P.S. bricks)
Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge. (Size 100 mm dia) (ISI Marked)
Providing and fixing heavy class SS grating plane including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge (Size 100 mm dia) (ISI Marked)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, Lotous or equivalent having valid ISI license).
Making soak pit 2.5m diameter 3.0 M deep with 45x45cm dry brick honey comb shaft with bricks of class designation 75mm and S.W. drain pipe 100mm diameter 1.8 m long complete as per standard design with FPS bricks.
SUB HEAD - WATER SUPPLY, DRAINAGE, PUMPS & EQUIPMENT
Supply, assembly, erection, testing and commissioning of pumping system comprising the following:
Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (wilo,ebara and matherplatt etc.)
Pump Capacity 180 lpm, at 30 m head (1 working + 1 standby) (Domestic water relift pump).
External Sewerage and Rain water Harvesting
Construction of rain water harvesting well of 2.5 meter dia and 3.0 meter effective depth with the operation of earth work in excavation and drilling with RC/DC/Calyx rig having 400/450mm dia bore size up to aproximate 45m deep in all kind of starta including hard rock, back filling with available exavated earth, with necessary compaction and shifting of surplus earth outside by mechanical means as directed by the Project Incharge, PCC 1:5:10 , 200mm thick foundation concrete, brick work in cement mortar 1:4 (1 cement : 4 coarse sand), PVC coated safety steel foot rest of 12mm dia MS bars grouted rigidly in cement concrete 1:2:4 @300mm c/c, 200mm thick RCC tank cover slab in cement concrete M20 i/c providing and placing necessary steel raft, bars and to keep the provision of removable slab of approx. 1mx1m size, filling 300mm, 300mm & 300mm thick of 40-65mm nominal size graded stone aggregate, small stone and sand layer respectively, CI vent pipe, (100mm dia), 250mm dia uPVC slotted pipes 6Kg./sq cm working pressure, filling around the slotted pipes and packing 3mm to 6mm sized graded and screened rounded pea gravel duly washed fabricating and placing grating at the mouth of pipes, placing 560mm dia SFRC manhole cover with frame etc. i/e all necessary materials and equipments required for all relevant operations as shown in the drawing
Construction of brick masonry desilting chamber of size 200x100x60cm (effective depth) before rainy well with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement inside and rough plaster on outside, including fixing of grating , neatly finished complete in all respects including neccessary excavation, refilling and disposal of surplus earth, complete as per attached Sketch.
Excavation of trenches of required width for pipes etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning soil as required, in layers not exceeding 20cm depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed outside the site to the approved dumping ground. Minimum width of the trench should be external dia plus 400mm. Trenches to be excavated with required slope and shall be aligned as per drawing .
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing, fixing, jointing, testing and commissioning of UPVC “NU-DRAIN” for Drainage and sewerage/strom water application Pipe conforming to IS:15328 with all fittings such as bends, tees, elbow. The wall thickness of pipe and technical characteristic conforms to IS:15328 in SN8 stiffness class. The fitting dimension conforming to BS: EN1401-1998. The jointing to be completed with rubber ring/solvent weld joint as suitable at site for above basement level.(Aprroved Make- Supreme/prince/jain)
200 mm diameter
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With Sewer bricks conforming to IS : 4885
Supplying and fixing C.I. cover without frame for manholes:
Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg.
FIRE PUMPS AND ACCESSORIES
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
1620 lpm at 70 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects,as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
1620 lpm at 70 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 70 m Head
CONTROL PANELS
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
INCOMING
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A
OUTGOING
Main Fire Pump
Jockey Pump
DIESEL ENGINE CONTROL
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming toIS1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
150 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Note: Pipe upto 50 mm dia shall be threaded joints, with Ductile iron fitting above 50 mm shall be welded joints As per NBC 2016 & IS Code 15105
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia (wall thickness 6.3 mm)
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : for pump room
80mm dia
100mm dia
150mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required
100mm dia
150mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
100mm dia
150mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
3 way - 150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (E&M)
Providing and fixing MS cabinet (size 750x600x250 mm) fabricated from 16 gauge MS sheet with full front glass door & locking arrangement for pad lock with suitable shelves for keeping 25 Nos. spare sprinklers & one no. spanner properly fixed in shelves. Cabinet shall be painted with enamel paint of approved shade. (Cost shall include 20 Nos. spare sprinklers (5 Nos side wall 20Nos pendent, one No. spanner and 5 rolls of teflon tape ).
Note: All valves shall be of PN16 rating
PORTABLE FIRE EXTINGUISHERS
Providing & fixing of ISI marked (IS:15683) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667 of not more than 0.667 and wall suspension bracket
Capacity 4.5 kg
6 Kg. ABC Powder type fire extinguishers are manufactured and marked to Indian standard IS: 15683. Suitable first aid appliance for fighting fires in Class A, B & C fire that is wood, textile, flammable liquids & gases.
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube,high pressure discharge hose,discharge nozzle, ISI marked as per IS:2878 finished externally with red enamel paint.
Capacity 22.5 kg.
Electrical
Sub-Head : WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Make:- CCI/havells/polycab
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Make:- CCI/havells/polycab
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make:- CCI/havells/polycab
2 X 1.5 sq. mm +1X 1.5 sq. mm earth wire (For Light)
2 X 2.5 sq. mm +1X 2.5 sq. mm earth wire (for Computer 5amp)
4 X 4 sq. mm +2X 4 sq. mm earth wire
4 X 10 sq. mm +2X 6 sq. mm earth wire
4 X 16 sq. mm +2X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make:- NORTHWEST(PLATIA), SCHNEIDER(ZEN CELO), MK (BLENZE), L&T(Englaze).
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make:- NORTHWEST(PLATIA), SCHNEIDER(ZEN CELO), MK (BLENZE), L&T(Englaze).
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. Make:- NORTHWEST, SCHNEIDER, MK , L&T.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Sub-Head : MCCB, MCB & OB'S
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB Make:- Schnider ACTI-9 / SIEMENS Betagaurd(8GB32)/Hager Novello
4 way (4 +12), Double door
6 way (4 +18), Double door
8 way (4 +24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) Make:- Schnider ACTI-9 / SIEMENS Betagaurd(8GB32)/Hager Novello
6 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) Make:- Schnider ACTI-9 / SIEMENS Betagaurd(8GB32)/Hager Novello
6 way (4 + 18), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MAKE:- SCHNIDER(ACTI - 9)/SIEMENS(BETA GUARD)/L&T (AU).
Single pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. MAKE:- SCHNIDER (ACTI - 9) / SIEMENS ( BETA GUARD) / L&T (AU).
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.MAKE : SCHIENDER / SIEMENS / ABB
100 A, 16 KA MCCB
125 A, 16 KA MCCB
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required. FOR LIFT MAKE:- SCHNIDER(ACTI - 9)/SIEMENS(BETA GUARD)/L&T (AU).
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Sub-Head : EARTHING
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. (For Transformer/MLP/MDB/HT Panel/HT Meter)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. (For Transformer/UPS)
Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (FOR EX. LIGHTING FEEDER PILLAR)
Supplying and laying 25 mm X 5 mm G.l strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required.
Sub-Head : LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.l. tube, having single prong at top, with 85 mm dia 6 mm thick G.l. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.l. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc as required.
Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) ____
Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) //
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.l. strip, 125 mm long, with 4 nos. of G.l. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.l. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Sub-Head : MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable Anti Rodent of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. MAKE : CCI , HAVELLS / POLCAB
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable Anti Rodent of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. MAKE : CCI , HAVELLS / POLCAB
Above 120 sq. mm and upto 400 sq. mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.l. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Sub-Head : MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. MAKE:- COMET/PEECO/Siemons/Dowells
3½ X 300 sq. mm
3½ X 240 sq. mm
3½ X 185 sq. mm
3½ X 50 sq. mm
4 X 25 sq. mm
4 X 16 sq. mm
4 X 10 sq. mm
2 X 10 sq. mm
Sub-Head : HT CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. MAKE : CCI / HAVELLS/POLYCAB
Above 120 sq. mm and upto 400 sq. mm
Sub-Head : HV CABLE JOINTING & END TERMINATION
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Sub-Head : MISC. CIVIL ITEMS
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
INTELLIGENT FIRE ALARM SYSTEM
Two Loop Panel.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 4 zone, with microphone assembly complete as required.
CABLING & WIRING
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. MAKE :CCI / HAVELLS POLYCAB
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. MAKE :CCI / HAVELLS/POLYCAB
speaker cable Two pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
SUBHEAD I - WIRING
SUBSATION EQUIPMENTS
TWO POLE STRUCTURE WITH GO-DO SWITCH
Supplying, fixing, testing and commissioning of two pole structure for receiving 11 KV 3 phase incoming line for dept. comprising of :-
2 nos 11 mtrs long, Steel pole as per sate electicity board(SEB) specifications.
Cement Concrete foundation (1:2:4), 2250 mm below ground and 450 mm above including excavation and refilling etc as shown on drawings.
Steel cection, channels, angles, flats, clamps, GI nuts, bolts and required hardware etc. of different sizes for cross arms, bracings, supports for pole, insulators, lightning arrestors, GO switch, GI pipe for 11 KV cables, supports for terminations, including anti climbing barbed wires, danger plate as per specification of SEB.
11 KV class disc / pin / support insulator complete with clamps and fixing hardware etc.
3 nos , one per phase ,11 KV station class thyrite type lightning arrestors complete with mounting arrangement on the incoming overhead line along with earthing connections complete as per specification and as required.
1 set of G.O. Air break switch with DO fuse 400 Amp. With gang operated devices, with pad locking arrangement. Operating rod, supports, complete with operating handle and locking arrangement complete as per UHBVN.specification and as required.
50 Mtrs. - size 6/1/4.09 mm ACSR Conductor and connectors for tapping the connection and for connections with in two pole structure with heat shrinkable insulating sleeves for protection of connections etc as shwon on drawing.
50 mtrs -Earth connection with 50 x 6 mm GI Strip.
SUPPLY & INSTALLATION OF TWO POLE STRUCTURE WITH GO-DO SWITCH
11 KV ENERGY METER
Supply, fixing , testing and commissioing of Energy meter for the 11 KV connections including testing of the meter by SEB lab and control cabling from CTPT to the meter complete with all respect as per the norms and the requirement of SEB.
OIL TYPE TRANSFORMER
Supplying, installation, testing and commissioning of 400KVA, 11/0433 KV, 50 Hz, Dyn 11, outdoor ONAN type,copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x185sqmm XLPE cable of 11 KV grade arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5 & as per specification attached complete in all respects as required at site.
11KV HT PANELS
Design, manufacture, assembly,Testing & inspection at works, supply, and delivery (at Site), of 11kV, 350 MVA, in-door type Switchgear Panel with horizontal Isolation and Horizontal draw out vacuum circuit breaker, having anti pumping and trip free feature and complete In metal clad floor mounted vermin proof panel board, fabricated out of minimum 2mm thick CRCA sheet as per specifications. The panel shall be complete with all accessories / fitting / wiring, cable termination boxes suitable for 3C x 185 Sqmm XLPE armored, aluminium conductor cable for incoming and outgoing feeder, foundation bolts etc. The Panel shall be complete with required for Metering and protection relays,CTs/PTs and other related accessories, as required as per SLD and as per specifications. The Panel Shall consisting of following:-
1 Nos 11 kV, 350 MVA, 630A, Electrically operated, draw-out VCB complete with stored energy mechanism for manual operation, three position isolator/ earthing switch with manual operating mechanism & auxillary switch with 6NO + 6NC contacts, busbars, interlocking and earth bar etc.as per specifications. Incommer shall be provided with necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc.
Breaker shall be provided with the following for metering Indication and protection:
One (1) set of CTs of ratio 20/5A with metering and protection cores. Metering core shall be of class 0.5 and of 5VA, the core for protection shall be of 15VA and class 5P10.
One (1) set of PTs of ratio 11KV/rt3 / 110V/rt3 , class 0.5 and of burden 100 VA.
One (1) No. Multifunction meter (MFM-1) with RS-485 Port suitable for measurement of voltage, currents, power factor, frequency, Energy (KWH, KVARH KVAH), Power (KW, KVA and KVAR), harmonics and maximum demand indication.
One (1) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue).
One (1) set of Red/ Green indicating lamp for close and open position.
One (1) No. amber indicating lamp for auto trip.
One (1) No. clear indicating lamp for trip circuit healthy.
One (1) No. blue indicating lamp for spring charged.
One (1) Set of Power Pack
One (1) No Hooter
One (1) Set of Multifunctional, Protection Relay with communication compatibility and with min. protection 51, 51N, 27 & 59
Master Trip Relay.
Trip circuit supervision relay
Note : Necessary Co-ordination shall be done by the Panel Manufacturer / Vendor with the vendor of "Gas flooding system" for fire protection, for making suitable provisions in the panels, at the Design stage, Manufacturing stage, stage of testing at works & stage of commissioning at site.
SUPPLY & INSTALLATION OF MAIN DISTIBUTION BOARD AS DESCRIBED ABOVE MAKE SCHIENDER / SIEMENS /ABB OR THEIR AUTHORISED CHANNEL PARTNER
MAIN LT PANEL
Design, manufacture, supply, installation, testing and commissioning of following Utility panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 2mm thick CRCA sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber . The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line Diagram.
Important Notes: Common for all Switchboard:
The BOQ shall be read inconjunction with general notes, specification and Single Line Diagram (attached for Ref.). Incase of any discrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered.
ALL MCCB Shall Be Ext ROM And Spreader Links
All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C releases. All rating MCCB's shall be thermalmagnetic type.
Incoming MCCBs shall be provided with micro processor based releases O/C, S/C, and Earth fault under voltage, over voltage protection releases.
Outgoing MCCBs shall be provided with variable thermal magnetic O/C, short circuit protection.
All feeder doors shall have pad locking arrangement.
All TP feeders shall have solid isolable neutral link.
All power contactors including NIC shall be of AC3 duty.
All meters are digital type.
Panel shall be powder coated of approved shade with minimum 60 micron thickness.
ACB's/MCCB's in one particular panel shall be of one similar make.
Size of Voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded terminal shall be used in the panel.
Bus bar chamber shall be kept at top of the all panels.
All bus bar shall be insulated with coloured PVC Sleeve i.e.RYB,BK as per colour code.
Internal wiring of panel shall be with size 2.5sqmm Flexible Copper Conductor for CT circuit and control wiring with 1.5 sqmm.
All indicating light shall be LED type .
Each vertical section of floor mounted panel shall have independent base frame (75mm x 40mm) size made out of 3 mm sheet steel (LT Panel & DG Panel).
All the makes shall be as per Client approved make list only.
Note : Necessary Co-ordination shall be done by the Panel Manufacturer / Vendor with the vendor of "Gas flooding system" for fire protection, for making suitable provisions in the panels, at the Design stage, Manufacturing stage, stage of testing at works & stage of commissioning at site.
OUTDOOR TYPE MAIN LT PANEL
INCOMER
2 Nos. 630Amp 36KA 4P MCCB having microprocessor based over current, short circuit & earth fault, under & over voltage protection incomer shall be complete with following.
METERING FOR EACH INCOMER
One No. Digital Multifunction meter with RS-485 port suitable for measurement of voltage, currents, Power Factor, Frequency, Power & Energy (Conzerv EM 6400 or equivalent) with one set (3 Nos.) of CTs of ratio 600/300/5A (Dual Core) Class 1.0, 15VA.
One (1) set of 600/300/5A, (Dual Core) C.L 1.0 CTs for input to APFC relay. (Only for Transformer)
Three phase indicating lamps (LED type) with MCB.
ON OFF TRIP indicating lamps (LED type).
PROTECTION FOR EACH INCOMER
Master trip relay
IDMT relay
One (1) set of 600/300/5A, (Dual Core) C.L 5P10 CTs for input to protection relay.
INTERLOCKING
Provide the interlocking between transformer & D.G Incomeing Breaker in such a way that Grid supply and DG supply can not be paralleled in any circumstances..
BUSBAR
1 Set of 800A, TPN Aluminum bus bars with colour coded sleeves.
OUTGOING UNITS
1 Nos. 250Amp TPN MCCB 25KA with thermal magnetic releases.
1 Nos. 200Amp TPN MCCB 25KA with thermal magnetic releases.
5 Nos. 63Amp TPN MCCB 16KA with thermal magnetic releases.
1 Nos. 40Amp TPN MCCB 16KA with thermal magnetic releases.
1 Nos. 250Amp TPN MCCB 16KA with thermal magnetic releases.(SPARE)
3 Nos. 63Amp TPN MCCB 16KA with thermal magnetic releases.(SPARE)
All Outgoing MCCB having ON,OFF,TRIP Indication LED Lamp.
SUPPLY & INSTALLATION OF MAIN DISTIBUTION BOARD AS DESCRIBED ABOVE MAKE:- TRICOLITE, ADLEC, SIMON FABRICATOR JAMMU, Electricfield
MAIN DISTIBUTION BOARD-1
INCOMER
1 Nos. 250Amp 16 KA 4P MCCB complete having microprocessor based over current, short circuit & earth fault protection incomer shall be complete with following.
METERING FOR EACH INCOMER
3 Nos. Cast resin current transformers of Class 1.0 for metering.
Three phase indicating lamps (LED type) with MCB.
ON OFF TRIP indicating lamps (LED type).
BUSBAR
1 Set of 300A, TPN Aluminum bus bars with colour coded sleeves.
OUTGOING UNITS
4 Nos. 100Amp TPN MCCB 16KA with thermal magnetic releases.
6 Nos. 63Amp TPN MCCB 16KA with thermal magnetic releases.
All Outgoing MCCB having ON,OFF,TRIP Indication LED Lamp.
SUPPLY & INSTALLATION OF MAIN DISTIBUTION BOARD AS DESCRIBED ABOVE MAKE:- TRICOLITE, ADLEC, SIMON FABRICATOR JAMMU, Electricfield
MAIN DISTIBUTION BOARD-2
INCOMER
1 Nos. 200Amp 16 KA 4P MCCB complete having microprocessor based over current, short circuit & earth fault protection incomer shall be complete with following.
METERING FOR EACH INCOMER
3 Nos. Cast resin current transformers of Class 1.0 for metering.
Three phase indicating lamps (LED type) with MCB.
ON OFF TRIP indicating lamps (LED type).
BUSBAR
1 Set of 300A, TPN Aluminum bus bars with colour coded sleeves.
OUTGOING UNITS
2 Nos. 100Amp TPN MCCB 16KA
6 Nos. 63Amp TPN MCCB 16KA
All Outgoing only MCCB having ON,OFF,TRIP Indication LED Lamp.
SUPPLY & INSTALLATION OF MAIN DISTIBUTION BOARD AS DESCRIBED ABOVE MAKE:- TRICOLITE, ADLEC,, SIMON FABRICATOR JAMMU, Electricfield
EXTERNAL LIGHTING FEEDER PILLAR OUT DOOR TYPE
INCOMER
1 Nos. 40Amp 16KA 4P MCCB complete having microprocessor based over current, short circuit & earth fault protection incomer shall be complete with following.
1 Nos. 60Amp AC3 4P Contactor with timer be complete as required.
METERING FOR EACH INCOMER
3 Nos. Cast resin current transformers of Class 1.0 for metering.
Three phase indicating lamps (LED type) with MCB.
ON OFF TRIP indicating lamps (LED type).
BUSBAR
1 Set of 100A, TPN Aluminum bus bars with colour coded sleeves.
OUTGOING UNITS
09 Nos. 6/32Amp TPN MCB 10KA
SUPPLY & INSTALLATION OF EXTERNAL LIGHTING FEEDER PILLAR AS DESCRIBED ABOVE MAKE:- TRICOLITE, ADLEC,, SIMON FABRICATOR JAMMU, Electricfield
MCB FOR DB's
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. MAKE:- SCHNIDER (ACTI - 9) / SIEMENS ( BETA GUARD) / L&T (AU).
UNINTERRUPTED POWER SUPPLY SYSTEM
Supply, Installation, Testing and Commissioning of true parallel redundant 1 x 30kVA, online, UPS system suitable for providing power supply to emergency lighting and Computerised Control panel load of approved make, suitable for incoming 440 volts, single phase +10 % -20%, 50 Hz, supply and three phase 440 volts, output voltage, variation ± 1%, including inbuilit , rectifier/dual converter, static switch, inverter, filters, Bypass & static transfer switch for automatic switch over without giving any break of power, maintenance bypass switch, Microprocessor/software controlled annunciation, protection (including against input phase reversal), and menu run diagnostic module, associated cabling and connections/terminations, erection including associated foundation/masonorey or RCC work for mounting on base channels etc. complete as per specifications and as required.
Supply, Installation, Testing and Commissioning SMF VRLA Battery Banks for UPS stipulated in item 1 above, having 30 minutes back up time at full load with interconnecting cables, racks and standard accessories UPS above. Battery shall comply with relevant regulations & Battery racks shall be made of acid resistant material and shall be supplied inclusive of above item.
Supplying, installation, testing and commissioning of accessories like Battery Rack, Interconnecting links, DC circuit breaker and cable between UPS & battery bank for above UPS.
SUPPLY OF FIXTURES
Supply of the following light fixtures complete with housing, reflectors, complete with all accessories i.e. driver, lamp, holders etc. complete as required. MAKE HAVELLS / PHILIPS / WIPRO
12W LED Recessed Celling Light Fixture.
15W LED Recessed Celling Light Fixture.
36W LED Recessed Celling Light Fixture.
6W LED Bulk Head Light Fixture
12W LED Surface Light Fixture
40W LED T5 Light Fixture
1200 Dia Fan
225MM Dia Ex. Fan
LT CABLES
FIRE SURVIVAL CABLES
Providing, installing, testing and commissioning of Fire Survival Armoured Cable (600/1000V) with Aluminium/Copper Conductor having crosslinkable EPR insulation and LSZH inner and outer sheath as per BS- 7846 for copper and IEC -60502-1 for Aluminium & BS – 8519 (Latest Edition). Should retain circuit integrity as per BS 8491:2008-120 mins & BS 8434-2 (latest edition). MAKE HAVELLS / CCI / POLYCAB
50 sq mm 3.5 Core cable Al. conductor (For Fire Pump)
16 sq mm 4 Core cable Al. conductor (For LIFT)
LT NORMAL CABLE
Supplying of following sizes of XLPE/ PVC insulated Aluminum/ Copper conductor and Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.MAKE CCI / HAVELLS / POLYCAB
XLPE insulated Al. Ar.Cable
3.5C x 300 sq.mm.
3.5C x 240 sq.mm.
3.5C x 185 sq.mm.
3.5C x 50 sq.mm.
4C x 25 sq.mm.
4C x 16 sq.mm.
4C x 10 sq.mm.
2C x 10 sq.mm.
HT CABLE
Supplying of following sizes of XLPE/ PVC insulated Aluminum/ Copper conductor and Armoured, overall PVC sheathed 11 KV grade cables conforming to relevant IS code and technical specifications. MAKE CCI / HAVELLS / POLBCAB
3C x 185 sq.mm.
EXTERNAL LIGHTING
Supplying, erection, testing and commissioning of HOT dip galvanized octagonal steel pole of 7 meter height made out of 3mm thick sheet having bracket length of 500mm long including built in connector control box with flush cover and supplying and fixing of 6 Amp SP MCB C-Series and 32 Amp heavy duty connector etc. for making connections with suitable size of copper wire and thimbles / lugs in the connector box, base plate of 200mm x 200mm x 12mm thick, bolt size 4 nos 24mm long, bolt length 750mm, projected bolt length 125mm and anchor plate thickness of 3mm. The pole shall be installed in cement concrete foundation (1:3:6) i.e. 1 cement, 3 coarse sand and 6 graded stone with the help of anchor bolts of 3/4" dia by laying iron bar mesh fabricated with 6mm dia iron bar, earthing of pole, connection etc. complete as required.
Supplying and fixing of Street light fixture 70 Watts LED complete with glass cover etc. and its wiring with 3 x 2.5 sq.mm PVC insulated copper wire from junction box complete ).MAKE: PHILIPS / WIPRO / HAVELLS
Providing and fixing 6SWG dia GI Wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required.
Supplying, laying and connecting 2 nos 2.5. sq.mm copper conductor PVC insulated 1100 volts grade wires from terminal block to light fixture along with end terminations and including the cost of 1 no. 2.5 sq.mm PVC insulated copper wire for earthing of the light fixture complete as required.
Sumit Gupta
Sanjiv Kumar Sharma
M/S CONSTRUCTION ENGINEERS
TBA INFRASTRUCTURE PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
SBD.pdf
Tender Documents • 2.25 MB
BOQ_327794.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid