Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance K701 MARVEL ZEPHYR KHARADI PUNE MAHARASHTRA 411014 UDYAM MH 26 0652381 27AADCE9912F1ZM B R | PUNE | MAHARASHTRA | 411014 | Admitted-Finance |
| 2 | Admitted-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
20 Mar 2021, 9:00 amClosed
COL N K SAH
CWE AF LOHEGAON
Provision of consultancy work services for P Block at Sion of Air Force Station Mumbai
2021_MES_426026_2
30011/JOB/26/2020/E3
Limited
Miscellaneous Works
Works
30 days
GE AF THANE
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
22 Mar 2021
12 Mar 2021
22 Mar 2021
12 Mar 2021
20 Mar 2021
14 Mar 2021
Provision of consultancy work services for P Block at Sion of Air Force Station Mumbai. Bldg No. P-23 to P-26 each in (G+4) Storeys WORK DETAILS:- 1. Preliminary site visit, data collection, calculation and preparation of any retrofitting detail if required, providing the structural stability certificate with reference to current state and expected life after proposed measures.- Each Job. 2. Testing work as per the standard method for the structures as below:- (a) Concrete cores for compressive strength -08 Nos. (b) Surface Hardness by Rebound hammer -08 Nos. (c) Ultrasonic pulse velocity for quality of concrete -08 Nos. (d) Petrography -08 Nos. (e) Sulphate content -08 Nos. (f) Half-cell potential -07 Nos. (g) Cover depth -07 Nos. (h) Carbonation depth -07 Nos. (j) Chloride concentration -07 Nos. Consultancy should comment on the safety of bldg and should clearfy propose actions there of including preparation of BoQ for retrfitting.
Bldg No. P-27 to P-30 each in (G+4) Storeys WORK DETAILS:- 1. Preliminary site visit, data collection, calculation and preparation of any retrofitting detail if required, providing the structural stability certificate with reference to current state and expected life after proposed measures.- Each Job. 2. Testing work as per the standard method for the structures as below:- (a) Concrete cores for compressive strength -08 Nos. (b) Surface Hardness by Rebound hammer -08 Nos. (c) Ultrasonic pulse velocity for quality of concrete -08 Nos. (d) Petrography -08 Nos. (e) Sulphate content -08 Nos. (f) Half-cell potential -07 Nos. (g) Cover depth -07 Nos. (h) Carbonation depth -07 Nos. (j) Chloride concentration -07 Nos. Consultancy should comment on the safety of bldg and should clearfy propose actions there of including preparation of BoQ for retrfitting.
RS ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .