Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹39.0 L+₹2.8 L (7.60%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Not Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
25 Jul 2023, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N)P/T- 41 OF 23-24 REP/ MAINT OF COOLING APPLIANCES SUCH AS AIR CONDITIONERS WATER COOLERS, DEEP FREEZERS REFRIG AC PLANTS DESERT COOLERS INSTALLED AT VARIOUS LOCATIONS/ BLDGS AND OTHER ALLIED WK IN THE AREA OF AGE E/M (N) AREA UNDER GE (N) PUNE
2023_MES_607222_1
GE (N) P/TOKEN- 41 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹96,000
Yes
17 Oct 2023
30 Jun 2023
1 Aug 2023
30 Jun 2023
25 Jul 2023
13 Jul 2023
1 Jul 2023 - 6 Jul 2023
Amount
Servicing only of window type air conditioner in citu of capacity 1.5/ 2.0 Ton of any make and any type by replacing unserviceable parts (except compressor) from the machine including charging of Refrigerant if required, Brazing the suction / discharge tubes where required and cleaning of cooling coil, condensing coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defective thermostat switch, relay, capacitor and over load protector to achive proper cooling effect and testing commissioning complete all as specified and directed. (Note:- Additional gas required will paid & measured separately under relevant item.)
Taking out unserviceable Window type air conditioner of capacity 1.5/2.0 Ton of any make and any type by replacing unserviceable compressor and other parts from the machine. Brazing the suction / discharge tubes where required and cleaning of cooling coil, changing of wirings with proper size PVC insulated wires as directed. Install the Air conditioner at location where directed after proper repair and testing complete at site as per the satisfaction of Engr- in - charge.
Note for iten No 1 & 2 :- i) Compressor where ever is required shall be measured and paid separately under respective item. ii) Spares parts where ever is required shall be measured and paid separately under respective item of schedule A. iii) Unit rate is deem to be included for minor parts such as capilary tube, machine screw, washer, rubber bush etc required for proper setting of machine.
Supply only thermostat suitable for window type AC 1.5/2.0 ton capacity for 230 volt 50 Hz AC supply complete all as specified and directed.
Supply only PVC insulated, copper cable, 2.5 Sqmm , 3 core, complete all as specified and directed.
Supply only PVC insulated, copper cable, 4 Sqmm , 3 core, complete all as specified and directed.
Supply only for replacement of unserviceable swinging motor of indoor unit of split type AC up to 3TR capacity suitable for existing make/model complete all as specified and directed by Engr in charge
Supply only for replacement of blower motor with bush and washers as per existing make and model for split type AC up to 3 TR Capacity complete all as specified and directed.
Supply only for replacement of blower motor with bush and washers as per existing make and model for Window AC up to 2 TR Capacity complete all as specified and directed.
Supply only capillary tube special annealed double wound copper tubing suitable for 1.5/2 ton window type air conditioner of diameter 0.25 " bore as per existing complete all as specified and directed.
Supply only capillary tube special annealed double wound copper tubing suitable for 1.5/2 ton window type air conditioner of diameter 0.38" bore complete all as specified and directed.
Supply only cooling coil made out of copper tube as per existing coil capacity and specification suitable for 1.5/2 ton window AC of any make and type as per existing complete all as specified and directed.
Supply and fix condenser coil made out of copper tube per existing coil capacity and specification suitable for 1.5/2 ton window AC of any make and type as per existing complete all as specified and directed.
Supply and fix condenser coil made out of copper tube per existing coil capacity and specification suitable for 1.5/2 ton split AC of any make and type as per existing complete all as specified and directed. Note for iten No 13 :- i) Compressor where ever is required shall be measured and paid separately under respective item. ii) Spares parts where ever is required shall be measured and paid separately under respective item of schedule A. iii) Unit rate is deem to be included for minor parts such as capilary tube, machine screw, washer, rubber bush etc required for proper setting of machine.
Supply only hermetically/Rotary sealed compressor unit 1.5 TR capacity for window type AC as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make :- LG/Whirlpool/Blue Star/Godrej
Supply only hermetically/ Rotary sealed compressor unit 2 TR capacity for window type AC as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make :- LG/Whirlpool/Blue Star/Godrej
M & L for Taking out window type air conditioner of any capacity and make for shifting at other place after making necessary opening in window/ wall of any type and thikness, cutting of grill any type/ size fixing of AC after servicing, providing necessary plywood, commerical type, 6 mm thick of suitable size as packing material to cover the hole/ window complete all as specified and directed. Note :- Transportation for shifting of AC's will be provided by contractor and rate for same is deemed to be included in quoted rate.
Servicing only any type Split air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5/2.0 TR of any make and any type by replacing unserviceable parts from the machine including Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning complete all as specified and directed.
Supply only overload protector relay for split type AC of capacity 1.5 ton as per site requirement complete all as specified and directed.
Supply only running capacitor 36 MFD and complete all as specified and directed.
Supply only running capacitor 50+4, 50+6 MFD and complete all as specified and directed.
Supply only running capacitor 45 MFD and complete all as specified and directed.
Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed.
Supply only sub zero sensor for package type AC of existing makes and model of any capacity complete all as specified and directed.
Supply only display sensor for split type of capacity upto 2.0 TR AC of existing makes and model of any capacity complete all as specified and directed.
Supply only out door unit fan blade heavy duty of existing make Split AC of capacity 1.5 ton/ 2.0 ton as per existing complete all as specified and directed.
S & F for copper tubing of size 1/2” for discharge line any make of split AC of capacity 1/1.5 ton with insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed.
S & F for copper tubing of size 1/4” for discharge line any make of split AC of capacity 1/1.5 ton with insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed.
S & F for copper tubing of size 3/8” for discharge line any make of split AC of capacity 2 ton with insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed.
S & F for copper tubes of size 5/8” for Suction line of split AC of capacity 2 ton including insulation sheet of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed.
S & F for high wall blower fixed in indoor unit of make as per existing split AC 1.5/2 ton capacity including removal of old existing unsv one complete all as specified and directed.
S & F for indoor unit split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make/model as per existing including removal of old existing unsv one complete all as specified and directed.
S & F indoor unit for Inverter type split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make/model as per existing including removal of old existing unsv one complete all as specified and directed.
Taking down existing unserviceable outdoor unit fan blade motor and supply and fix new fan blade motor for outdoor unit of 1.0TR capacity Split AC make and capacity as per existing complete all as specified and directed.
Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 1.5 TR capacity Split AC of any make/model and capacity as per existing complete all as specified and directed.
Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 2.0 TR capacity Split AC of any make/ model and capacity as per existing complete all as specified and directed.
Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 3.0 TR capacity Split AC make and capacity as per existing complete all as specified and directed.
Taking down existing unserviceable outdoor unit condensor fan blade motor and supply and fix new fan blade motor for outdoor unit of 4.0 TR capacity Split AC make and capacity as per existing complete all as specified and directed.
Supply and fix for three phase preventer suitable for operation on 415 Volts 50 Hz AC supply including removal of existing unserviceable one compete all as specified and as directed. Make : L&T/ Minilec.
S & F for indoor unit split type air conditioner 2.0 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make/model as per existing including removal of old existing unsv one complete all as specified and directed.
S & F indoor unit for Inverter type split type air conditioner 2.0 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make/model as per existing including removal of old existing unsv one complete all as specified and directed.
S & F for flexible PVC pipe 20 mm dia heavy duty from outdoor unit to indoor unit including removal of old existing unsv one complete all as specified and directed.
Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 1.5 TR and supply and fixing new hermetically/Rotary/DC sealed compressor of as per site requirement for split AC of capacity 1.5 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make :LG/Whirlpool/Blue Star/Godrej
Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 2.0 ton and supply and fixing new hermetically/Rotary/DC sealed compressor of same make for split AC of capacity 2.0 TR as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make : LG/Whirlpool/Blue Star/Godrej
Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 3 TR and supply and fixing new hermetically/Rotary sealed compressor of same make for split AC of capacity 3 TR as per site requirement with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed. Make : LG/Whirlpool/Blue Star/Godrej
S & F for PCB (Printed circuit board) of indoor unit of 1.5/2.0 ton capacity split AC including removal of old existing unsv one complete all as specified and directed.
S & F PCB (Printed circuit board) for Inverter type AC indoor/outdoor unit of 1.5/2 ton capacity split AC including removal of old existing unsv one complete all as specified and directed.
S & F for new powder coated Mild Steel stand suitable for outdoor unit of split AC of existing size to install outdoor unit on wall/ floor as required on site with legs and bracing etc including removal of old existing unsv one complete all as specified and directed.
Taking down existing unserviceable outdoor unit and supply and fix new outdoor unit for 1.5 TR capacity Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired but with compressor of make as per existing complete all as specified and directed.
Taking down existing unserviceable outdoor unit and supply and fix new outdoor unit for 1.5 TR capacity Inverter type Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired but with compressor of make as per existing complete all as specified and directed.
Taking down unserviceable outdoor unit and supply and fix new outdoor unit for 2.0 capacity Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired with compressor of make as per existing complete all as specified and directed.
Taking down unserviceable outdoor unit and supply and fix new outdoor unit for 2.0 capacity Inverter type Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired with compressor of make as per existing complete all as specified and directed.
Supply and fix remote control for AC as per sample of any make, type, capacity including removal of extg unsv one complete all as specified and directed.
M & L for taking out Split type air conditioner indoor and outdoor unit complete with copper tubing of any size and make for shifting at other place after making necessary opening size, cutting of wall any type/ thickness and fixing of AC after necessary servicing, making suitable arrangement for fixing of AC complete all as specified and directed. Note :- (a) Transportation for shifting of ACs will be provided by contractor and rate for same is deemed to be included in quoted rate.
M & L for comphrensive maintenance of package air conditioner of capacity 11.00 TR including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
M & L for comphrensive maintenance of Package/ AC of 7.50 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
M & L for comphrensive maintenance of Package AC of 5.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
M & L for comphrensive maintenance of cassete/split type AC of 4.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
M & L for comphrensive maintenance of tower AC of 4.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
M & L for comphrensive maintenance of split/tower/cassette AC of 3.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
M & L for comphrensive maintenance of tower/cassette AC of 2.0 TR capacity including servicing the entire system, including cleaning the machines, cleaning the filters by water, cleaning the ducting and checking the all electrical connections, contactors, relays, oil greasing to electrical motors etc for smooth functioning of the plant complete all as specified and directed. (Note :- Maintemance of the plant will be carried out once in three month and will be masured as unit "Each Job")
Removing the old unserviceable sealed compressor unit from ductable package/ split AC of any make of capacity 7.50 TR and supply and fixing new hermatically sealed compressor of same existing make for ductable split AC of capacity 7.50 TR working with non CFC refrigerent including supply and charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete and all as specified and directed.
Removing the old unserviceable sealed compressor unit from ductable package/split AC of any make of capacity 5.0 TR and supply and fixing new hermatically sealed compressor of same existing make for ductable split AC of capacity 5.0 TR working with non CFC refrigerent including supply and charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete and all as specified and directed.
Removing the old unserviceable sealed compressor unit from ductable split/ tower/ package AC of same existing make of capacity 4.0 TR and supply and fixing new hermatically/Rotary sealed compressor of as per site requirement for ductable split AC of capacity 4.0 TR working with non CFC refrigerent including supply and charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete and all as specified and directed.
Removing the old unserviceable sealed compressor unit from ductable split/Tower AC of same existing make capacity 3.0 TR and supply and fixing new hermatically/Rotary sealed compressor of as per site requirement for ductable split/tower AC of capacity 3.0 TR working with non CFC refrigerent including supply and charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete and all as specified and directed.
Removing the old unserviceable sealed compressor unit from ductable split/Tower AC of same existing make of capacity 2.0 TR and supply and fixing new hermatically sealed compressor of same make for ductable split/tower AC of capacity 2.0 TR working with non CFC refrigerent including supply and charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete and all as specified and directed.
S & F for PCB (Printed circuit board) of ductable type AC unit 7.5 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas
S & F for PCB (Printed circuit board) of ductable type suitable for AC unit 5 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas
S & F for PCB (Printed circuit board) of ductable type package/ tower/ split AC suitable for unit 4.0 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas
S & F for PCB (Printed circuit board) of ductable type package/ tower/split AC suitable for unit 3.0 TR of existing make including removal of extg unsv one complete all as specified and directed. Make: Blue Star/ Voltas
Supply and fix DC motor for Inverter type split AC 1.5/2.0 TR outdoor unit 30 W 230 Volts single phase with 1300 RPM suitable for existing make/model complete all as specified and directed.
Supply and fix DC motor for Inverter type split AC 1.5/2.0 TR indoor unit 18W 230 Volts single phase with 900 RPM suitable for existing make/model complete all as specified and directed.
Supply only electric blower fan motor 1/20 HP 230 Volts single phase with 950 RPM suitable for water cooler complete all as specified and directed.
S & F for contactor for smooth functioning of control panel including removal of extg unsv one complete all as specified and directed. Make: Siemens Cat No. 3TF44 or equivalent from L&T. Note :- If Cat No. is revised, equivalent cat No. from latest Catalogue shall be considered.
M&L for leak detection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required on site quantity to achieve desire cooling complete all as specified an directed.
(a) Split type AC 1.5 TR capacity
(b) Split type AC 2.0 TR Capacity
(c) Split type AC 3.0 TR capacity
(d) Split type AC 4.0 TR capacity
(e) Split type AC 5.0 TR capacity
(f) Split type AC 7.5 TR capacity
M&L for leak detection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required on site quantity to achieve desire cooling complete all as specified an directed.
Window type AC 1.5 TR capacity
Window type AC 2.0 TR Capacity
M&L for replacement of unsv contactor kit of split type AC as per existing make & model up to 3 TR complete all as specified and directed.
Taking out water cooler of any capacity and make, from site for servicing, cleaning of cooling coil, condenser coil and water storage tank, oiling to blower motor, checking of electrical circuit and replacement of defective spare parts such as capacitor, relay, over load protection, blower motors etc, found defective on site as required, testing for smooth functioning etc complete all as specified and directed. Note :- Supply only spare parts shall be measured and paid separately under relevant Items given below.
Supply only overload protector of SR-2612 to water cooler complete all as specified and directed.
Supply only starting capacitor 40/60/80/100 MFD for water cooler any type/size complete all as specified and directed.
Supply only running capacitor 10 to 36 MFD complete for water cooler any type/size complete all as specified and directed.
Supply only relay for water cooler of any type & capacity as per existing and complete all as specified and directed.
M&L for leak detection by nitrogen pressure test in refrigerant system of Refrigerator,Water cooler & Deep freezer by cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required on site quantity to achieve desire cooling complete all as specified an directed.
(a) Refrigerator of any capacity and make.
(b) Water cooler of any capacity and make.
(c) Deep freezer of any make and capacity.
Supply only electric blower fan motor 1/20 HP 230 Volts single phase with 950 RPM suitable for water cooler complete all as specified and directed.
S & F for Brass ball valve, 15 mm dia, ISI marked, high pressure with polythelene float (Wall thickness of floats is 1.5 mm ) and fly nut complete screwed for iron pipe or brass ferrule and fixed, minimum finished weight 0.28 Kg each ball valve as specified in SSR Part I including removal of extg unsv one complete all as specified and directed.
S & F for Push Cock of size 15mm bore ,Chromium plated,cast copper alloy, heavy duty,screwed for iron pipe or for brass ferrule including removal of extg unsv one complete all as specified and directed.
S & F for thermostat suitable for water cooler of capacity 40 ltr to 300 ltrs for 230 volt 50 Hz AC including removal of extg unsv one complete all as specified and directed.
S & F for condensing coil suitable for water cooler of capacity 40 Ltr/hr cooling capacity as per existing including removal of extg unsv one complete all as specified and directed.
S & F for condensing coil suitable for water cooler of capacity 60 Ltr/hr cooling capacity as per existing including removal of extg unsv one complete all as specified and directed.
S & F for PVC drain out pipe 32 mm dia bore medium grade as per existing including providing necessary GI clamps, nut bolt etc including removal of extg unsv one complete all as specified and directed. Make : Prayag /Supreme/Prince
M & L for preparation of old steel surfaces by using wire brush /emery paper etc and making the surface smooth by using putty and painting to the outer Cover/external surfaces of water cooler with two coats of synthetic enamel paint and re-writing the SM / MES No etc capacity of water cooler 40/60 Ltr/hr complete all as specified and directed.
S & F for PVC connection of 450mm long, 15mm bore with chromium plated brass check nuts at both side of superior quality including removal of extg unsv one complete all as specified and directed.
Removing the old unserviceable sealed compressor unit from water cooler of 40/60/80 ltrs capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent including supply and charging of non CFC refrigerent gas and oil to adequate level ,and testing complete all as specified and directed. Make of compressor : Shriram / Kirloskar / Usha
S & F for MCB Protected Socketed with sheet enclosure SRCD (Socket residual current device) single pole and neutral enclosure with a two pin and earth plug and socket complete with 20 Amps MCB single pole.
Taking out Refrigerator of any capacity and make from the site for servicing, Cleaning of evaporator coil, condenser coil, vegetable tray, checking the electrical circuit and replacement of unserviceable spare parts like indicator lamp,evaporator coil , relay as required, testing for smooth functioning etc complete all as specified and directed. Note :- Supply only spare parts shall be measured and paid separately under relevant Items.
Supply only bio metallic fuse for double door refrigerator of any make and model as per site requirement complete all as specified and directed.
Supply only timer switch for double door refrigerator of any make and model as per site requirement complete all as specified and directed.
Supply only indicator lamp of refrigerator, any watt, thread/ pin type as per site requirement complete all as specified and directed. Make - Bajaj / Philips / Surya.
Supply only evaporator coil for Refrigerator of any type & capacity as per existing and complete all as specified and directed.
Supply only relay suitable for refrigerators of different capacities and makes for smooth functioning of refrigerator as per existing and complete all as specified and directed.
S & F for condensing coil for Refrigerator of any type & capacity as per existing including removal of extg unsv one as directed
S & F for thermostat for Refrigerator of any type & capacity as per existing including removal of extg unsv one complete all as specified and directed.
S & F for Chiller door of approved brand, for refrigerator of any make and capacity 165/180 ltr as ordered and suitable for fitted with existing cooling chamber of Refrigerator including removal of extg unsv one complete all as specified and directed .
S & F for Chiller door of approved brand, for refrigerator of any make and capacity 220/ 250 / 300/ 310 ltr as ordered and suitable for fitted with existing cooling chamber of Refrigerator including removal of extg unsv one complete all as specified and directed .
S & F for Chiller tray of approved quality/ Brand suitable for 165/ 180/ 220/ 250/ 300/ 310 Ltr cap refrigerator including removal of extg unsv one complete all as specified and directed
S & F for Vegitable / Fruit tray of approved quality / Brand suitable for 165/ 180/ 220/ 250/ 300/ 310 Ltr cap refrigerator including removal of extg unsv one complete all as specified and directed.
S & F for Magnatic door gasket any make of refrigerator of capacity 165 to 300 ltr including removal of extg unsv one complete all as specified and directed.
M & L for preparation of old steel surfaces by using wire brush /emery paper etc and making the surface smooth by using putty and painting to the outer Cover/external surfaces of refrigerator of capacity 165/170/200 Ltr with two coats of synthetic enamel paint and re-writing the SM/MES No etc complete all as specified and directed.
M & L for preparation of old steel surfaces by using wire brush /emery paper etc and making the surface smooth by using putty and painting to the outer Cover/external surfaces of refrigerator of capacity 250/286/300 Ltr c Ltr with two coats of synthetic enamel paint and re-writing the SM/MES No etc complete all as specified and directed.
Removing the old and unserviceable sealed compressor unit from refrigerator 310/300 ltr capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent including supply and charging of non CFC refrigerent gas as per existing for Refrigerator in exchange of defective uncut sealed unit including making connection and oil at adequate level and testing complete all as specified and directed.
Taking out Deep freezer of capacity 165/200/310 Litres from the site for servicing, applying one coat of synthetic enamel paint in side, cleaning of evaporator coil and condenser coil, checking the electrical circuit and replacement of unserviceable spare parts thermostat , Over load protection,relay, starting capacitor, running capacitor, testing for smooth functioning etc.complete all as specified and directed. Note :- Supply only spare parts shall be measured and paid separately under relevant Items given below.
Supply only thermostat suitable for deep freezer of capacity 165 ltr to 300 ltrs for 230 volt 50 Hz AC supply complete all as specified and directed.
Supply only Over load protection suitable for deep freezer of capacity 200/300/310 Ltrs as per existing complete all as specified and directed.
Supply only relay suitable for deep freezer of any capacity as above as per existing complete all as specified and directed.
Supply only starting capacitor suitable for deep freezer of any capacity as above complete all as specified and directed.
Supply only running capacitor suitable for deep freezer of any capacity as above complete all as specified and directed.
S & F for Magnatic door gasket any make of deep freezer of capacity 165 to 310 ltr including removal of extg unsv one complete all as specified and directed.
Removing the old and unserviceable sealed compressor unit from deep freezer 310 /300 ltr capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent for deep freezer in exchange of defective uncut sealed unit including making connection and charging of non CFC refrigerent gas and oil at adequate level and testing complete all as specified and directed. Make: Shriram/ Kirloskar/ Usha
S & F for wood saving pads of desert coolers including taking out of old pads including removal of extg unsv one complete all as specified and directed.
S & F for tullu pump 0.6 KW, 1.25 Mtr head of desert cooler suitable for operation on 230 volt 50 Hz AC supply including removal of extg unsv one complete all as specified and directed.
S & F for blower motor of 1/8 HP, 1460 RPM for existing desert cooler suitable for operation on 230 volt, 50 Hz, AC supply including removal of extg unsv one complete all as specified and directed.
Supply and fix voltage stablizer with digital display for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 5 KVA suitable for AC complete all as specified.
Supply and fix voltage stablizer with digital display for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 4 KVA suitable for AC complete all as specified.
M & L Attending emergent complaints i.e Window/ Split Air conditioners any type, water cooler any type, Refrigerator any type including water leakage of AC carrying out minor repairs including replacing necessary capacitors, thermostat,relays, PCB etc as required to make the system in order/ functional complete all as specified and directed. Note :- Rate of spare parts shall be measured and paid separately under relevant items. Minor parts deemed to include in cost of item.
M & L Submain wiring with 3 runs of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including PVC casing and capping heavy duty ISI marked and its accessories including one run of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removal of extg unsv one c complete all as specified and directed. Note:- Two runs of 4 sqmm cable,one run of 4sqmm cable and one run of PVC casing caping will be measured as one unit.
Supply and Charging of non CFC Refrigerant Gas R -134a for AC plant water cooler, refrigerator and deep freezer of any type, make and capacity complete all as specified and directed.
Supply and Charging of non CFC Refrigerant Gas R -407C all as specified and directed.
Removing the old and unserviceable sealed compressor unit from refrigerator 165 to 265 ltr capacity and supply and fixing new hermetically sealed compressor working with non CFC refrigerent including supply and charging of non CFC refrigerent gas as per existing for Refrigerator in exchange of defective uncut sealed unit including making connection and oil at adequate level and testing complete all as specified and directed.
M & L for replacement of existing old unserviceable insulation of refrigerent pipes of split AC's upto 3 TR capacity all as specified and as directed.
M&L for servicing of elect control panel of AHU central/chiller type AC Plant by cleaning the panel with blower, checking of electric circuits/connections, replacement of unsv burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unsv item (taken as supply only) as directed by Engr-in-charge. Note:(i) Unserviceable parts as MCB, MCCB, contactor, relay etc. will be measure and paid separately (ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in item rate
M&L for servicing of 30 to 100 TR screw type water cooled chiller unit by authorised OEM service Engineer of voltas including cleaning of electric control panel & its parts, chiller units parts, checking all parameters of Microprocessor, MVPD and other controls including repairing of PCB /MVPD if reqd and setting the parameters as per design and outside conditions, descaling of condenser top up of refrigerant gas, oil if required and submission of service report to the Engr in Charge from authorised dealer of voltas. Make of installed AC plant-Voltas Note: spares, Refrigerant gas & oil shall be measured and paid in respective items.
Supply and fix in replacement of unserviceable MCS CT (CX1) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable MCB TPN 10 Amp C series complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable play relay (Sulzer MKG-2) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable voltage protection device complete all as specified and directed by Engr-in-charge
Supply and fix inreplacement of unserviceable contactor (3TS49) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable fuse unit (160 Amp) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Oil level switch complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable catch all core drier complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable Compressor oil (solest 120) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable Oil return line solenoid coil valve set complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable chiller line water pressure differential switch (Danfoss) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable condenser line water pressure different switch (indfoss) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable CT fan auto switch (Danfoss) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable water flow switch complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable chiller and condenser line sensor complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable liquid line sensor complete all as specified and directed by Engr-in-charge
M & L for repairing of unserviceable 100 TR screw compressor dismantling shaft seal, oil filters, pressure relief valve and reassembled after testing including pressure holding test with N2 for 24 hrs and non CFC gas charging complete all as specified and directed by Engr-in-charge. Note:- R134a gas charging will be measured and paid separately under relevent items.
Supply and fix in replacement of unserviceable AHU V belt size B130 complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable AHU blower motor shaft bearing complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Condensor motor bearing and water seal complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable AHU 1/4 Drier complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable V Belt Size A55 complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable AHU blower motor shaft bearing complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable Compressor Oil POE160 SZ complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable Condensor motor bearing and water seal complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable MCB TPN (C40) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable Siemens Contactor(3TF33) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unserviceable Condensor line water diffential Switch (indfos) complete all as specified and directed by Engr-in-charge.
M&L for taking out existing Unsv scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR 270A, Max Oper-58A, thermally protected system, LP side (PS 20 bar, TS max 53oC TS min-35oC, Vol 32.8I) HP side (PS 29.6 bar, TS max 68.3oC TS min-35oC, Vol 2.oI), having lubricant POE160SZ, heater etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make- Danfoss commercial compressors Model No-SZ185S4RC. Note:- Refrigerant gas shall be measured and paid in respective item.
Supply and fix in replacement of unserviceable Drier (EKD 307) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable MCB TPN (C32) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable MCB TPN (C20) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Overload Relay Range (0 to 10 amp) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Phase Relay (USP D1) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable L & T Star Delta Timer complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Auxiliary Switch (2NO/2NC) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable L&T Contactor MNX25 complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Indicator Lamp Green Colour complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Indicator Lamp Red Colour complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Indicator Lamp Yellow Colour complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Indicator Lamp Blue Colour complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Start Push Button complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Stop push button complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable L&T VAF Meter complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable L&T KWH Meter complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Connector 25mm complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of unserviceable Connector 63mm complete all as specified and directed by Engr-in-charge
M&L for Condensor pump bearing and seal replacement.
M&L for descaling of condenser with dilute sulphuric acid solution (as per OEM manufacturers specification) by using backwash pressure for circulation of solution and brushing with nylon brush by opening both side covers and cleaning/flushing out the dirt, sludge with water up to satisfaction of Engr in charge and re-fixing the side cover with new gasket, replacement of worn out nut, bolts & washers and leak detection complete all as specified of following:- (a) Capacity up to 30 to 100 TR
Material and labour for taking out unsv burnt electric motor of compressor/Cooling Tower/Blower/condenser and rewinding by removing the burn out copper coil & cleaning the motor and winding with copper wire of same gauge & turns including varnish, heating the winding including replacement of unsv bearing, bush etc. , refixing to its original place and testing after repair complete all as specified and directed by Engr in charge. for following capacity:- Note: Rates for transportation from site to workshop & return shall be deemed to be included in item rate.
(a) Up to 1 HP single Phase
(b) 5 HP to 7.5 HP 3 phase
M&L for taking down, dismantling complete and servicing of Monoblock Centrifugal pump set by greasing, cleaning the shaft replacing gland packing/bush bearing of existing size, replacement of unserviceable nut, bots & washers etc. for capacity 5 to 7.5 HP pump complete all as specified and directed by Engr in charge.
M&L for taking out U/S air filters of any capacity and size (610x310x50mm) as per site requirement incl S&F double united polymer fabric HDPE mesh air filter washable /cleanable type having efficiency 95% to 99% down to particles size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over a coat of red oxide primer, with lifting handles, Box/flanged type, aluminum spacer etc. all as per existing size as directed by Engr-in-charge.
M&L for taking out U/S air filters of any capacity and size (310x310x50mm) as per site requirement incl S&F double united polymer fabric HDPE mesh air filter washable /cleanable type having efficiency 95% to 99% down to particles size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over a coat of red oxide primer, with lifting handles, Box/flanged type, aluminum spacer etc. all as per existing size as directed by Engr-in-charge.
M&L for taking out U/S air filters of any capacity and size (610x610x50mm) as per site requirement incl S&F double united polymer fabric HDPE mesh air filter washable /cleanable type having efficiency 95% to 99% down to particles size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over a coat of red oxide primer, with lifting handles, Box/flanged type, aluminum spacer etc. all as per existing size as directed by Engr-in-charge.
M&L for servicing of cooling tower motor of capacity 5 to 7.5 HP, greasing, replacement of u/s bearing/bush/shaft etc. as directed by Engr-in-charge.
M&L for servicing, cleaning of Cooling tower up to 100 TR Cap including taking out perils , cleaning the same and refixing, cleaning the storage tank, removal of all sludge , servicing, greasing of cooling tower motor with hub assembly etc. complete up to satisfaction of Engr in charge.
M&L for leak detection of water cooled condenser unit of chiller type AC plant up to 100 TR cap including cutting, brazing to leak condenser coil & testing after brazing work with nitrogen pressure etc complete all as specified & directed by Engr in charge. Note:- (i) Necessary topping up of refrigerant gas & oil shall be measured and paid in respective items.
M&L for chiller water pipe line insulation class O nitrile rubber based thermal insulation 19 mm thick with treated woven glass fiber covering of 0.18mm thick, density of 200+25 GSM, Tensile strength 275+20 Kg/mm for exposed to sun application (green colour) including fixing with adhesive which is specifically formulated for pipe insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof, including taking out existing unsv insulation material, cleaning the pipe surface complete all as directed by OEM & specified by Engineer-in-Charge. Make - Armacell/Vidoflex/Eurobatex.
M&L for replacement of Non return valve (NRV) including taking out existing unsv butter fly valve and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller/condenser pipe line) of following size
(a) 50 mm dia
(b) 100 mm dia
M&L for replacement of condensor/chiller water pressure gauge including taking out existing unsv one and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller/condenser pipe line) all as specified and as directed.
M&L for replacement of thermostate meter size 15mm including taking out existing unsv one and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller/condenser pipe line) all as specified and as directed.
M&L for temprature gauge of range 0 - 100 degree celcius in replacement of old unsv as per sample all as specified and as directed.
M&L for replacement of spray pump 1.0 HP including taking out existing unsv spray pump and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller/condenser pipe line).
M&L for water pressure gauge of range 0 - 150 psi in replacement of unsv water pressure gauge as per sample all as specified and as directed.
M&L for replacement of defective sprinkler assy of complete as per existing type & model of cooling tower cap 30 TR all as specified and as directed.
M&L for replacement of defective sprinkler assy of complete as per existing type & model of cooling tower cap 100 TR all as specified and as directed.
M&L for carefully painting on central AC plant water cooled type having condenser, Cooling tower, condenser water pipe line, refrigerant pipe line, control sluice valve/butter fly valves, angle iron foundation frames, compressor motor, compressors, drain water MS duct, condenser , chiller monoblock pump sets etc. of central type ac plant complete with two coat of synthetic enamel paint after scrapping out existing rusted/bubbled paint as per existing colour coding and marking water flow directions with suitable size arrow mark complete including cleaning the stains of paint after painting complete all as specified and directed by Engr-in-charge Note :- for measurement one complete plant taken as one job
M&L for taking out Unsv PVC fills of cooling tower of 30 to 100 TR cap (bottle/rectangular type) after taking down cooling tower motor and keeping aside, cleaning the hydrant pipe, sprinkler assembly and inside complete body of cooling tower complete up to satisfaction of Engr in Charge.
Supply & fixing PVC fills of cooling tower of 30 to 100 TR as per OEM standard fixing sequance including cutting & filling the gaps so that the water of cooling tower spread equally complete all as specified and as directed Engr in Charge.
M&L for cleaning of Y strainer & pot strainer of central AC plants 50 to 100mm of chiller line, condensor line by carefully opening the top & taking out the strainer and refixing after cleaning/washing out the line durt/sludge & replacement of defective nut bolts, rubber gasket, damaged strainer as per existing size if required after cleaning filling water in condensor/ chiller line by using additional pump, taking out the air in chiller & condensor line complete all as reqd at site & directed by Engr-in-charge.
M&L for replacement of unsv water strainer of size 65mm including replacement of Unsv rusted nut bolts, washers, & gasket complete all as red at site & directed by Engr in charge.
M&L for replacement of unsv water strainer of size100mm including replacement of Unsv rusted nut bolts, washers, & gasket complete all as red at site & directed by Engr in charge.
Taking of defective micro processor printed cicuit board of split AC of existing Make/Model upto 3TR capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed by Engr-in-Charge.
Taking of defective micro processor printed cicuit board of Inverter type split AC of existing Make/Model upto 2TR capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed by Engr-in-Charge.
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
ANAND ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .