| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹28.5 L+₹2.7 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹30.7 L+₹4.9 L (18.9%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S ROHIT CONSTRUCTION L2 | MSR INFRATECH L3 | Sh. Manoj Nagar L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. | 64 | CUM | 180 ₹11,520 | 180 ₹11,520 | 150 ₹9,600 Lowest |
| 2.00 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed | 36 | CUM | 100 ₹3,600 | 80 ₹2,880 | 70 ₹2,520 Lowest |
| 3.00 | M&L for earth filling including spreading and levelling in layer not exceeding 25 cm thick including watering and well ramming complete all as specified and directed. | 10 | CUM | 200 ₹2,000 | 80 ₹800 Lowest | 200 ₹2,000 |
| 4.00 | M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed.
Note:- Punned thickness of sand shall be measured and paid. | 6 | CUM | 300 ₹1,800 Lowest | 600 ₹3,600 | 400 ₹2,400 |
| 5.00 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. | 19 | CUM | 100 ₹1,900 | 80 ₹1,520 | 60 ₹1,140 Lowest |
| 6.00 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | 5 | CUM | 2,500 ₹12,500 Lowest | 2,850 ₹14,250 | 3,000 ₹15,000 |
| 7.00 | M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. | 1 | CUM | 3,000 ₹3,000 Lowest | 3,500 ₹3,500 | 3,500 ₹3,500 |
| 8.00 | M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed . Note - Reinforcement and form work shall be measured and paid separately. | 7 | CUM | 7,000 ₹49,000 | 7,000 ₹49,000 | 4,800 ₹33,600 Lowest |
| 9.00 | M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. | 15 | CUM | 7,000 ₹1,05,000 | 7,500 ₹1,12,500 | 4,800 ₹72,000 Lowest |
| 10.00 | M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. | 3 | CUM | 7,000 ₹21,000 | 7,500 ₹22,500 | 4,800 ₹14,400 Lowest |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
20 Oct 2025, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
SPECIAL REPAIR OF OFFICER MESS KITCHEN AND MESS STAFF ROOMS IN BUILDING NO P-517 OF SIKH REGT AND ADDITION / ALTERATION OF MES COMPLAINT CELL IN ZONE-III AREA UNDER GE(S) JAIPUR AT MIL STN JAIPUR
2025_MES_732000_1
GE(S)/J-45P/2025-26 8969/E8
Open Tender
Civil Works
Item Rate
180 days
GE (S) Jaipur
Class D and category a(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹58,000
Yes
15 Dec 2025
22 Sept 2025
27 Oct 2025
22 Sept 2025
20 Oct 2025
12 Oct 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
M&L for earth filling including spreading and levelling in layer not exceeding 25 cm thick including watering and well ramming complete all as specified and directed.
M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.
Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed . Note - Reinforcement and form work shall be measured and paid separately.
M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts and similar work complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in fins, fascia, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the similar work complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D (D-dia of bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including cleaning the holes by air blowers prior to fixing the new steel bars in position using Lokfix E77, a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive strength (EN196) not less than 122 N/sqmm, Flexural Strength (EN196) not less than 66 N/sqmm, E Modulus (EN ISO 527-2) 6300 N/sqmm or of equivalent make but excluding the cost of reinforcement, complete all as per direction of Engineer-in- Charge for 10mm shear connectors. Note : 1. Anchoring chemical shall comply with ETA 21/0354, ETA 21/0518 for anchoring bars for 10mm dia complete all as specified and directed. 2. Reinforcement shall be measured and paid separately.
M&L for applying bond coat of epoxy bonding agent & cement in 1:1 ratio for bonding old and new concrete on damaged surfaces after applying anticorrosive paint over cleaned rusted steel surface including demolition old RCC surfaces (chajjas, fins, beams , borders etc and applying 30mm thick polymer modified mortar in CM 1:3 including mixing of polymer latex additives for repair of Chajjas fins, border etc complete all as specified and directed. Note :- (i) Cleaning of rusted part of steel and applying anticorrosive paint over it. (ii) Qty of ploymer to be used 15% by weight of the cement or as per manufacturer instruction. (iii) Use of electrical mixer to get the homogeneous dough on bond coat surfaces. (iv) To achieve required thickness repeat this step after 24 hrs as required. (v) Keep the surfaces moist using water fog for 5 to 7 days etc complete all as specified and as directed. (vi) Rate shall be inclusive of all necessary scaffolding for building of height upto two storey. Make :- (i) The epoxy bonding agent shall be Krishna / Dr Fixit / MC Bauchemie / M/s Cemistik / Sika or equivalent as approved by GE. (ii) Polymer latex addictive shall be of Sika / Fosroc / Dr Fixit or equivalent as approved by GE.
M&L for 40mm thick damp proof course (DPC) in cement concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. Note :- Water Proof Compound (WPC) shall be measured and paid separately under respective items.
M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L brick work using old size bricks with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good cutting exc 20 cm girth complete all as specified and directed.
M&L for cutting holes in brick walls exc half brick but not exc one brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. Note:- The depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall.
M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed 15 mm thick in CM 1:6 complete all as specified & directed.
M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams etc and similar work, vertical or to batter for rough finished flat concrete surfaces complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed
M&L for form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves, for flat rough finished concrete surfaces complete all as specified and directed.
M&L for form work to fins, louvers, fascia, for flat, rough finished concrete surfaces complete all as specified and directed.
M&L for Form work to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal rough finished concrete surface complete all as specified and directed
M&L for form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof and sides of bands in walls, horizontal or sloping and similar work for rough finished concrete surface exc 10 cm but not exc 20 cm wide complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sqm but n.exc 4.0 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed.
S&F second class hard wood 30 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 35 mm thick second class hard wood rail and style plain framed factory made panelled shutter (two panel) with lock rail and panel of 9 mm BWP commerical ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 40 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and both face are covered with decorative face veneer with lipping / frame to match complete all as specified and directed.
Taking down shutters of any description exc. 1.00 Sqm but n.exc. 2.00 Sqm each complete all as specified and directed.
S & F for solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2020 Part-II complete all as specified and directed
S & F Factory made Solid PVC Moulded door shutter with particle board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts of extruded section 200 mm long complete all as specified and directed.
S&F aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy of 300 mm length of bolt complete all as specified and directed.
S&F butt hinges, medium weight, cold rolled mild steel 100 mm long complete all as specified and directed.
S&F brass handle of 100mm size, cast type, polished bright complete all as specified and as directed.
S&F extruded aluminium alloy handles fabricated type anodised of 150 mm size complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor, over all length of cover plate 140 mm complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for wire netting of galvanised steel wire 0.71mm dia and size of mesh in 20mm fixed with tinned tacks or wire staples.
M&L for auto close hinges, stainless steel, bright finish or electrogalvanised fixed complete all as specified and as directed.
S&F 25 mm dia stainless steel, silver & chrome finish, fancy type, anti-rust curtain rod complete as all specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bar 5 mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and directed
S&F pressed steel frames of size 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed.
M&L for powder Coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note:- Glass and other filling material in panels shall be measured and paid seperately.
S&F for powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note-Glass and other filling material in panels shall be measured and paid seperately
S&F providing, fabricating & assembleing and fixing anodized aluminium fixed partion using Jindal make, medium weight aluminium section as follow :- (i) Horizontal members - size 63.50 x 38.10 mm @ 0.75kg/m c/c spacing shall not exceed 90cm. (ii) Vertical members - size 63.50 x 38.10 mm @ 0.75kg/m c/c spacing shall not be more than 90cm. (iii) Bottom portion - 03 inch height portion, including prelaminated board 12mm thick and all necessary clips, rubber beading, aluminium beading and fixing to the adjoing / existing wall/portion beading etc. (iv) Top portion - 05mm thick plain glass / grounded glass with all necessary fittings / fixture etc, complete all as specified and directed. Note:- Section given above are of Make Jindal, the contractor may use similar section of other make as mentioned in Appx 'B' of PS.
M&L for roof tiles, Mangalore pattern, interlocking at side joints including screed bed 15 mm thick in CM 1:4 complete all as specified and directed.
M&L for preparation of roof surface by sweeping and removing all dust /dirt and cleaning with water etc and water proofing treatment to roof slab with following description as under : (i) The surface shall be painted with one coat of cold applied bituminous primer conforming to IS:3384, @ 0.40 kg per sqm. (ii) APP based polymeric membrane not less than 3 mm thick, weighing not less than 3.5 kg/sqm, reinforced with polyster non-woven fabric (weighing not less than 150gm/sq m). It shall be laid by torch application. Side overlaps shall be 75 mm and the ends shall be 100 mm and all overlaps and joints shall also be sealed by torch application. For parapets, membrane shall be taken to a height of min 60 cm and then inserted inside the parapet in a groove. The same shall be finished by a membrane flashing. (iii) Coved fillet in PCC(1:2:4) type B0 of radius 75mm shall be provided at the junctions of roof and parapet wall /mumty/ chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen, 30/40 grade conforming to IS:73, applied @ 1.20 kg per sqm over a coat of bituminous primer, conforming to IS:3384 applied @ 0.40 kg per sqm. (iv) Applying a coat of aluminium paint as per manufacturer instruction.
M&L for 12mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with screws to timber frame work complete all as specified and directed.
M&L for suspended false ceiling (Make - Armstong ANF AH 95 or equivalent as approved by GE) extra micro-perforation size of 600 x 600 x 15 mm ceiling tiles over suspension metal system (MICRO LOOK) designer grid (15 mm grid 8mm return) SILHOUETTE X L 15 MM (NOMINAL) of Make Armstorng or equivalent make including necessary hanging system arrangement which is required to be made from existing RCC roof /stone /slab /AC sheet of existing ceiling complete all as specified and directed.
M&L for 18-20 mm thick High Density high moisture resistant (HDHMR) board for kitchen cupboard / door shutter of make Action tesa / Pearlwood or equivalent make as approved by GE, one side colour / white laminate and other side decorative as in modular kitchen / cabinets / door shutter fixed with minifix hardware wherever required including edge band 22mm wide, 0.80mm thick of matching colour on exposed surfaces of board fixed with polymaster adhesive of REHAU make or equivalent including trimming edges of edge band to true line of thickness of board by manual trimmer, fixed to wall etc. complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate, 50 mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface, area of each tile exc. 0.08 sqm but n.exc. 0.16 sqm, 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing on treads of step and landing of stair including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring 40 mm thick surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in flooring 40 mm thick surface finished even and smooth with out using extra cememt complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7 mm / 300x 600x7 mm / 450x 300x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for double charged vitrified Ceramic tiles light shade cut out of 8mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in vertical surface such as dado / skirting / risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for double charged vitrified Ceramic tiles light shade 8mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed or bedding layer 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for chequered cement concrete tiles 25 cm x 25 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigments over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 as in ceiling surface and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 05 mm thick in CM 1:3 on ceiling surface and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering on stone masonry or other than fair faces of brick work of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for 15 mm thick cement plaster in one layer in CM 1:4 on concrete surface over roof slab finished even and smooth without using extra cement using WPC @ 3% by weight of cement over and including application of cement slurry @3 Kg/sqm after cleaning, sweeping the RCC slab to remove dust before application of cement plaster complete all as specified and directed.
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc.
M&L for preparation of old decorated surfaces of wall by complete removal of existing treatment complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and apply two coat of white wash including including 1 mm thick wall care putty complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling by complete removal of existing treatment and apply two coat of white wash including 1 mm thick wall care putty complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying two coat of oil bound distemper (OBD) complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface of wall of any description and applying two coats of oil bound distemper over and including 1 mm thick wall putty complete all as specified and directed.
M&L for preparation of new surface of wall of any description and applying two coats of oil bound distemper (OBD) over and including 1 mm thick wall putty all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coat of oil bound distemper complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two cement based paint complete all as specified and directed.
M&L for preparation of new surface of walls of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed. Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE. Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc.
M&L for preparing of old decorated surfaces of wall (Plastered or unplastered) including cornices plaster and other wall features by washing, rubbing down and stopping of distmpered, surface to be repaired by filling putty in holes & depression if required, to obtain even and uniform surface etc and applying two coats of Plastic Emulsion Paint (Luxury /Royal) on wall white or tinted including scaffolding arrangement, trestles, ladders etc complete all as specified and directed.
M&L for preparation of new surface of walls of any description with a coat of 2mm thick wall putty complete all as specified and directed.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
M&L for french polishing on surfaces of any description width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats till shining complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
Dismantling of AC/PVC water tank and S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position complete all as specified and directed.
S&F in repair bib taps cast copper alloy with crutch or butterfly handle, long body, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated of 15 mm bore dia of pipe complete all as specified and directed.
S&F for 15mm bore dia of pipe brass CP mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.
S&F in repair for 15mm bore dia of pipe brass CP kitchen mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.
S&F in repair for 15mm bore dia of pipe brass CP wall mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.
S&F stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed.
S&F in repair stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed.
S&F ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 20 mm bore dia of pipe complete all as specified and directed.
S&F PVC connection 15 mm size bore with PTMT nuts of length 450 mm complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) branch piece single (single Y) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction double,(double T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
M&L PVC (SWR) 'P' trap of 110 mm bore including jointing with solvent cement complete all as specified and directed
M&L PVC (SWR) floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed
M&L PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed
S&F in repair Soap dish, any type fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm, bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repair Water closet vitreous china squatting pan, orissa pattern 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) and including provision of lime concrete bedding ,'P' or 'S' trap 100 mm bore , flushing pipe ,anti-syphonage pipe and connection etc and making good to floor complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed.
M&L in repair for Wash basins, Vitreous China, white, flat back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets & cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed. Make :Jaquar,Kohler & Grohe
S&F kitchen plate rack of size 900 mm x 900 mm x 250 mm made out of 1 mm thick stainless steel sheet with shelf and dividing steel bars shelf fixed on wall with rawl plug and screws etc complete all as sapecified and directed.
S&F in repair kitchen plain basket of stainless steel size 520 x 485 x 100 mm of grade SS-304 complete all as specified and directed. Make : Godrej / Hindware / Lifetime or equivalent make as approved by GE.
S&F in repair kitchen cup & saucer basket of stainless steel size 520 x 485 x 100 mm of grade SS-304 complete all as specified and directed. Make : Godrej / Hindware / Lifetime or equivalent make as approved by GE.
S&F in repair kitchen plate / thali basket of stainless steel size 520 x 485 x 100 mm of grade SS-304 complete all as specified and directed. Make : Godrej / Hindware / Lifetime or equivalent make as approved by GE.
S&F in repair baskets guide channel of stainless steel suitable for running basket of grade SS-304, 50cm long and 30 to 40mm width including drilling over stone complete all as specified and directed.
S&F in repair kitchen cutlery & spoon basket (plain) of stainless steel size 520 x 485 x 100 mm of grade SS-304 complete all as specified and directed. Make : Godrej / Hindware / Lifetime or equivalent make as approved by GE.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core (Phase - Red, Neutral - Black) PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade PVC insulated and unsheathed cable inclosed in and including concealed PVC conduit 20 mm dia medium grade with all accessories ISI marked, including MS sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting fitting like switches, sockets fan regulators etc. including 1.5 Sqmm single core (Green colour) PVC insulated unsheathed copper earth continuity conductor FRLS cable 1100 V grade as continuous earth wire for one light / fan / bell point controlled by one, one way switch. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonry and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green), concealed in wall and drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for one 3 pin socket outlet 5 Amps on the same board with other switches, complete all as specified and as directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green), concealed in wall and drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 pin 5 Amps socket outlet on independent board, complete all as specified and directed. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sqmm (Green), concealed in wall, drawn into and including rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 Pin 15 Amps socket outlet on independent board, complete all as specified and directed. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Fan step regulator, 120W - 2 module complete all as specified and directed.
M&L in repair for sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 V grade with multistranded copper conductor ISI marked drawn through and including PVC rigid conduit / casing capping not less than 20mm and conduit accessories fixed on surface of wall / celing etc including provision of 1 Run of 6 Sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor as earth continuity complete all as specified and directed. Note : 02 Run of 06 Sqmm copper wire and 01 Run of 06 Sqmm copper earth wire along with PVC conduct shall be measured as one unit.
M&L in repair for sub main wiring complete with 4 Runs of 6 Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 V grade with multistranded copper conductor ISI marked drawn throughn and including PVC rigid conduit / casing capping not less than 25mm and conduit accessories fixed on surface/wall celing etc including provision of 1 Run of 6 Sqmm PVC insulated unsheathed FRLS cable with multi-stranded copper conductor as earth continuity complete all as specified and directed. Note : 04 Run of 06 Sqmm copper wire copper wire and 01 Run of 06 Sqmm copper earth wire along with PVC conduct shall be measured as one unit.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note : Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
S&F in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single Pole and 06 to 32 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed.
S&F in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F in repair sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB of capacity 20 Amps complete all as directed.
S&F exhaust fan, steel body AC single phase, 230V of size 450 mm sweep heavy duty with, blades, and frame and louvers complete all as specified and directed.
S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
S&F in repair LED lights fitting 1x20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F modular switch one way 6 A, 1 module complete all as specified and directed.
S & F modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F white cover plate with frame, 3 module complete all as specified and directed.
S&F white cover plate with frame, 4 module complete all as specified and directed.
S&F white cover plate with frame, 6 module complete all as specified and directed.
S&F in repair MCCB 4 pole, 100 Amps, 16 KA ,415 volt,AC thermal adjustable type between 70 to 100% including 4 spreader link set of same suitable for existing panel complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 8 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 12 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board TPN double door type concealed in wall 415 volt 4 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F ceiling rose 3 phase, PVC / polycarbonate, isolated body complete all as specified and directed.
M&L in repair for earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:3:6) type B-1 using 20mm graded stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm bore GI Pipe medium grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. Note :- 1. PCC Chammer shall be constructed atleast 2.5 metre away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner. 2. GI wire and protection pipe upto 7.5 meter from the earth plate electrode is deemed to be included in quoted rate. 3. Excavation for earthing to be done manually and Earth resistance below 3 Ohm should be obtained after measurement for every pit.
Fixing / hanging ceiling fan any sweep and connecting up including PVC flexible three core cable with copper conductor of size 16 / 0.20 mm from ceiling rose to fan of sufficient length and connecting complete all as specified and directed. Note : Old fan obtain from taking down shall be refixed.
Fixing only exhaust fan any sweep and connecting up including PVC flexible three core cable with copper conductor of size 16 / 0.20 mm from ceiling rose to fan of sufficient length and connecting complete all as specified and directed. Note:- Old exhaust fan obtain from taking down shall be refixed.
Taking down ceiling / exhaust fan any type, sealing cable end, dismantling blades and removing fan and blades to MES store complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep with minimum air delivery 210 cubic meter per minute (CMM) with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note:- The rate quoted by contractor shall deemed to be included for the followings : (i) The colour BLDC Fan shall be pearl white. (ii) Proper hanging arrangement like 0.45 meter down rod, canopy etc. (iii) Writing the Fan No. on fan body. (iv) Making connection with 1.5 Sqmm copper wire complete all as directed.
S&F electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and directed. Note:- Connection with geyser inlet and outlet with 15mm bore GI pipe including PVC pipe is included in the quoted rate
S&F in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN / FP and 40 to 100 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed.
S&F electrical chimney of 90 cm size, suction capacity not less than 11550 cubic meter/hr and air outlet size not less than 150 mm motion sensor touch control, turbo speed option, dual side touch control, blower type- metallic, speed 9, energy efficient BLDC motor complete all as specified and directed.
S&F white cover plate with frame, 12 module complete all as specified and directed.
S&F PVC blanking plate one module complete all as specified and directed.
Disconnecting and taking down Geyser and accessories of any type or make, safely and re-fixing after minor repair like heating element, thermostat, PVC connection pipe, cleaning, tightening of loose component etc and servicing in serviceable condition including provision of cable from ceiling rose or connector to geyser including painting of geyser by two coat of synthetic enamel paint of in white / off white colour by spraying including filling cavities with filler, after cleaning all dust etc. including writing Geyser No. on each geyser complete all as specified and directed.
S&F in repair LED street / security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floor, apron etc complete all as specified and directed.
Demolition of cement concrete un-reinforced in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of AC corrugated / semi corrugated or translucent sheet as in roof coverings complete all as specified and directed.
Dismantling of Mangalore pattern roofing tiles with ceiling tiles or slate roofing bedded in lime or cement mortar complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs/ blankets any thickness including cover fillets complete all as specified and directed.
M/S ROHIT CONSTRUCTION (BID ID -3455688)
MSR INFRATECH (BID ID -3457677)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
8969Tender.pdf
Tender Documents • 1.02 MB
BOQ_819543.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .