Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC tenderaccepted | |
| 2 | L2₹16.2 L+₹1.8 L (12.7%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
12 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faizabad
GE MES faizabad
SPECIAL REPAIR TO BLDG NO 22 AND SQUASH COURT OF HG LINE UNDER AGE BR I AT FAIZABAD
2020_MES_350920_4
9013/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹30,000
Yes
23 Nov 2020
28 Sept 2020
13 Oct 2020
28 Sept 2020
12 Oct 2020
29 Sept 2020
60 days
Amount
Demolition of Cement Concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) and removing rubbish off the premises complete all as specified.
All as item No 1 herein before but of any description and in any position not otherwise specifically provided for.
M&L 75mm thick Cement Concrete type D-2 1:4:8 (40mm graded crushed stone aggregate) as in sub base of floor complete all as specified.
M&L PCC type C-1, 1:3:6 ( 20 mm graded crushed stone aggregate) 75 mm thick as in plinth protection / paving finished fair and even complete all as specified. ( The width of plinth protection shall not be more than 75cms).
M&L PCC type B-1 1:2:4 (20mm graded crushed stone aggregate) 40mm thick as in floor finished surfaces even and smooth with using extra cement complete all as specified.
M&L PCC type B-0 1:2:4 (12.5mm graded crushed stone aggregate) 25mm thick as in floor finished surfaces fair and even to receive tile complete all as specified.
M&L screed bed or bedding layer of cement mortar 15mm thick in CM 1:6 for laying floor finishes to receive tiles complete all as specified.
M&L 10mm thick screeding bed on backing of verticles tiles in CM 1:4 complete all as specified.
M & L for antiskid ceramic heavy duty coloured tiles of size 300mmx300mmx8-9 mm thick, laid in floors set and jointed in neat cement slurry & pointed in white cement mixed with pigment to match the surface complete all as specified .
M&L for light shade Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L for light shade Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, as on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
S&F Glass dividing strips 3 mm thick and 38mm wide and inserted in position to conforming to design complete all as specified.
M&L PCC 1:3:6 type C-1 (20mm graded crushed stone aggregate) as in surface channels and drains complete all as specified.
M&L Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms moulds, mitred/stopped ends etc complete all as specified.
Taking down chowkhats with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm each complete all as specified.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified thickness of frame not less than 3mm.
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.
S & F 5.5mm thick glass pan ordinary quality and glazing with oil putty in square exc 0.5 sqm each pane complete all as specified.
S & F 5.5mm thick glass pan ordinary quality and glazing with oil putty in square n.exc 0.5 sqm each pane complete all as specified.
S&F Aluminium grill with aluminium anodized / powder coated mesh of size 75mm x 75mm with square tube (solid), 6mm dia Xpm type including fixing accessories such as suitable channel section and screwed at 300 mm centre to centre etc complete all as specified.
S&F plain solid straight chowkhats and framed wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints 2nd class hard wood complete all as specified.Type of wood SAL/ Biga Sal / benteak / Hollock
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, comercial type on both sides complete all as specified.
S&F 100mm mild steel butt hinges medium weight , cold rolled size of hinges complete all as specified.
S&F 200mm long mild steel barrel tower bolt store enamelled with bright bolts of long complete all as specified.
S&F MS pressed handle oval type stove enamel black 125 mm size complete all as specified.
S&F 300mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified.
S&F FI as in bands, straps, hold fast, twist clamp , two way or three way strap and similar articles conforming to Fe 310-O or Fe 410-O complete all as specified.
S&F Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like including all necessary labours, articles n exc 200 cu.cm each in 2nd class Hard Wood complete all as specified.
M&L tarring back of chowkats etc area tarred exc 0.1 Sqm but not exc 0.5 Sqm each complete all as specified.
All as per item No 30 herein before but small articles such as hold fast area tarred not exc 0.1 Sqm each complete all as specified.
M&L PCC type C-1, 1:3:6 (20mm graded crushed stone aggregate) as in bed plate complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
M&L Fe 410-W (Gde E-250 quality A) for Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M & L for E- board tiles ceiling on GI powder coated channel/Tee/Grid of make (Armstrong ) frame work with the following specification including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type BO / Cement mortar 1:3 complete all as specified and directed with following:- (a) M & L Plugging to wall around the rooms & supplying & fixing GI powder coated angle of make (Armstrong ) of size 25x25 mm (b) S & F of 1.60 mm dia GI wire suspenders with adjustable clamps including fixing to ceiling g dash free fasteners (c) S & F GI powder coated tee as in main & cross members at 595mm centre to centre to centre supported suspenders along with adjustable camp to maintain level. (d) S & F E- board (Make-Everest Industries Limited) ceiling tiles of size 595mmx595mm and 4-5 mm thickness, confirming to relevant IS in squares of GI powder coated tee with clips made to shape, shade and pattern of PVC board shall be as approved by GE, complete all as specified.
Demolition of Brickwork or stone/boulders masonry built in cement mortar including removing brick bats and rubbish off the premises complete all as specified .
M & L brick work with fly ash bricks, old size, straight or curved on plan exc 6 m mean radius built in CM 1 : 6 complete all as specified.
All as per item no. 39 but except bricks (old bricks retrieved shall be reused).
Taking down cement plaster on Brick or concrete surfaces including racking out joints hacking for key scrubbing down with water etc complete all as specified.
M & L rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing even and smoth without using extra cement complete all as specified .
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper(exterior grade) over a layer of chalk whiting, on plastered surface, preparatory to distempering to obtain smooth finish complete all as specified.
M&L for preparation of new plastered surfaces of walls, and applying two coats of cement based paint over a coat alkali resistant priming paint including curing complete all as specified .
M&L for preparation of old plastered surfaces of walls surfaces and applying one coat of cement base paint complete all as specified .
M&L for complete removal of existing treatment on surfaces of walls by wire brushing and washing, rubbing down and stopping of surfaces and applying two coats of oil bound distemper (exterior grade) over a layer of of chalk whiting or Wall care white Putty thickness not less than 2 mm complete all as specified .
M&L for preparation of decorated old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing , scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying 2 coats of oil bound distemper (exterior grade) over surface complete all as specified .
Repairs of damaged roof after complete removal of existing treatment and applying the following treatment all as directed in order of preedence as stated :- (a) "Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brush & dusting. Applying a layer of btuminious primer confirming to IS 3384 @ 0.4 Lit/Sqm on the surface. Laying 3mm thick APP membrane having non-woven polyster matt at core and under surface coated with plastic polythene film. Laying shall be done using btane torch maintaining 100mm i.e overlap & 150mm end overlap, sealing all overlaps complete including treatment at all junctions & corners. The membrane shall be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor" complete all as specified and as directed by Engr-in-Charge. Note : (i) Laying APP based polymeric membrane shall be done torch on method as per manufacture instruction. (ii) A minimum overlap of 100mm and 150mm should be made at the end of the polymeric membrane respectively and sealed all overlaps and joints as per manufactured instruction. (iii) APP based polymeric membrane shall be 3mm thick manufactured by M/s STP Ltd or M/s IWL or Pedilite. (iv) Bituminous primer shall be manufactured by M/S STP Ltd or M/s IWL or Pedilite (v) Rate of taking down OHT before operation and refixing the same after operation shall deemed to be included in the item rate where required.
M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified .
M&L cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
M&L for rendering 10mm thick in CM 1:4 on concrete surfaces finishing even and smooth without using extra cement and using water proofing compound all as specified . (WPC shall be measured & paid for separately)
M& L for 40 mm brick tiles laid on 15 mm thick bedding layer in CM (1:4) mixed with WPC (WPC shall be measured and paid seperately) over water proofing membrane and grouted and pointed flush in CM (1:3) with linseed oil @ 5% by weight of cement complete all as specified .
Supply only Liquid water proofing compound ISI marked as approved , complete all as specified.
M&L for cement concrete 1:2:4 type B-0 using 12.5mm ( graded crushed stone aggregate) as in filling of roof depressions, providing roof slopes or in roof kerbs including rounding complete all as specified.
M&L for Machine pressed precast concrete rubber moulded interlocking coloured paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade fixed with grey cement and pigment, laid over 25 mm thick white sand cushion, over 75 mm thick PCC 1:4:8 type D-2 using 40 mm ( graded crushed stone aggregate), etc, complete all as specified. (PCC & sand cushion will be measured and paid seperately).
M&L for fine Sand filling under floors or in foundation including watering and consolidation all as specified . (The compacted thickness shall be measured and paid for)
M&L 750mm height for stainless steel railing, welding, riveting, grinding complete all as specified .
M&L 20mm thick in CM 1:3 on fair faces of brick work mixing with cement and metalic hardner dust as per manufacturer's instruction as in squash court, surface to be fair and even complete all as specified .
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified.
M&L for One light/fan point controlled by one way switch 6 amps 240 volts, point wiring controlled with PVC insulated unsheathed multi stranded copper conductor (FR) cable of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) with one run PVC insulated unsheathed multi stranded copper conductor (FR) cable of size 1.5 Sqmm (as earth wire, colour code green) and connected to common earth dolly and drawn through in and including PVC Conduit medium grade, ISI marked (concealed) not less than 19.5 mm / 20 mm dia along with conduit fixing accessories and with suitable size pressed steel terminal box (thickness 1.6 mm) including painting with one coat of black bituminous paint (outer side) and in side primer with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/sockets/regulators complete, all as specified. Note - Colour code of cable will be as per IS pratice including making good surfaces as per existing specifications.
All as per item no. 59 but One 3 pin 6 Amps switch socket out let point on independent Board.
All as per item no. 59 but One 3 pin 6 Amps switch socket out let point on same board.
M&L for Point wiring with 2.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unsheathed cable 1100 volt grade drawn into and including non metalic rigid,ISI marked medium grade PVC conduit (concealed) of size not less than 20 mm dia with all acessories & fixing acessories such as MS shadle, cadium coated screws & rawl plug and also including PVC insulated ISI marked unseathed FRLS cable 1100 volts grade of size 1.5 sq mm copper conductor as earth wire connected to common earth dolly including pressed steel terminal box (1.6 mm thick) with painted (one coat of black bituminous paint outer surface and two coats of enamel paint in inner surface) and with 3 mm thick laminated sheet for provision of switch & sockets as per specified SSR and as directed by Engineer- in- Charge. :- Note - Colour code of cable will be as per IS practice including making good surfaces as per existing specifications.
S&F switch piano flush type 5 Amp one way, single pole, 240 volts complete all as specified.
S&F switch socket combination 2 in 1, 5 pin 5 Amp flush type, 240 volts complete all as specified.
S&F switch socket combination 5 in 1, 5 and 16 Amp flush type , ISI marked 240 volts complete all as specified.
S&F LED tube light fitting,1X18 watt cool day light (CDL) surface and wall mounted decorative ultra slim square profile with extruded polycarbonate, environmental friendly, energy efficient ready to use pack fitting including provn of twin core multi stranded copper cable of size 1.5 Sqmm from ceiling rose to tube light fitting complete all as specified.
Supply & fixing LED street light fitting 100W Rectangular LED Flood Light with innovative thermal management and available in multiple optics and equipped with IP66 protection with required connection wire multistand 2.5 Sqmm twin core sheathed weather proof up to ACSR conductor/ Ceiling rose and all as specified.
Supply and fixing Exhaust fan Copper wound 230 V 300 mm sweep including provision of cable from ceiling rose or connector to fan including exhaust fan shutter or louver on wall frame complete all as specified.
Supply & fix wall mounting air circulator fan 230 volts single phase oscillating 450 mm sweep complete all as specified.
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. NOTE - The cost of earth strip upto and including 7.5 mtr only from the top of earth electrode are deemed to be included under this item and additional earth lead, if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’.
S&F epoxy powder coated MCB, DB, double door SPN 8 way for MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall all as directed.
S & F MCB SPN, 32 Amps 230 Volts C series 10 KA, including necessary connection complete all as specified and as directed.
S & F MCB SP 6 to 32 Amps, 230 Volts C series 10 KA, including necessary connection complete all as specified and as directed.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, 10 Sq mm 2 core, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Excavating in trenches n. exc 1.5 mtr wide and n.exc 1.5 mtr depth for foundation, laying cables etc and getting out in soft / loose soil complete all as specified
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in soft / loose of soil complete all as specified
Removing excavated material to a distance n. exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, well ramming completed all as specified.
Supply and laying well burnt sub class ‘B’ bricks (designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified.
M&L for GI pipe light grade of 40mm bore with all fittings fixed to walls, ceilings or laid in floors for cable protection complete all as specified.
PUMA POWER
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .