Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹26.5 L+₹2.8 L (11.7%)Rejected-AOC | L2 | Rejected-AOC Higher rate | |
| 3 | L3₹31.6 L+₹7.9 L (33.2%)Rejected-AOC | L3 | Rejected-AOC Higher rate | |
| 4 | L4₹33.2 L+₹9.4 L (39.8%)Rejected-AOC B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | L4 | Rejected-AOC Higher rate |
Tender Value
₹33.6 L
EMD Value
₹67,200
Closing Date
3 Aug 2020, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI ARMY HOSPITAL R AND R COMPLEX RAO TULA RAM MARG DELHI CANTT 10
SPECIAL REPAIRS TO ROOM NO 130A PRINCIPAL IFA AND ASSOCIATED OFFICES AT SOUTH HUTMENTS, PVC LAMINATES FLOORING IN STAIRCASE OF MAIN BLDG OF HQ IDS AT KASHMIR HOUSE AND ADDN/ ALTN TO TECH AREA STORES AT AFDC IN THE AOR OF AGE BR KASHMIR HOUSE UNDER
2019_MES_298301_2
GE/ND-59/2019-20
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE NEW DELHI
₹67,200
Yes
20 Aug 2020
13 Jul 2020
5 Aug 2020
13 Jul 2020
3 Aug 2020
20 Jul 2020
Amount
Dismantling floor,wall & ceiling boards of any description as in panelling ceiling, partition, cub boards etc incl cover fillets in any surfaces complete
S&F prelaminated PVC rigid foam sheet wall panelling of 5 mm thick stuck on inner frame work of 35 mm wide strips of 5 mm thick rigid foam sheet. The strips should have a groove of 6 mm width and 2 mm depth for sinking the head of screw used to fix the strips to the all and should be placed vertically at equal intervals of 300 mm C/C. The PVC strips to be fixed to the all using 65 mm long MS screws through the groove in the strip by using PVC fasters including necessary moulding workon doors, windows, pillars and opening etc complete all as specified and directed .Make:- Rajshri Note:- (a) Work for fixing of wall panelling shall be got executed through manufacturers authorised applicators only under the close supervision of their technical staff. (b) The entire qty of wall panelling and their allied ancillaries shall be procured directly from the manufacturer or their authorised dealer only.
M&L for GI powder coated micro preforated micro look false ceiling with fleece lay- in- type 0.50mm thick, suitable for grid/frame module of 600mmx600mm size complete with GI powder coated grid consisting of silhouette main T runner 15mm suspended at 1200mm centre to centre and cross T runner of 15mm size suspended at 600mm centre to centre suspended by 4mm GI rod from roof slab including steel fastner wall angle and T with interlocking arrangement as required for framing grid suitable for module size 600x600mm ceiling etc complete all as per specification and directed (Make : armstrong/hunterduglas)
Dismantling floor hearth or wall tiling including cement mortar bedding and removing rubbish of the premises
M&L 600 X 600 X (9-10) mm thick vitrified tiles (double charge light shade) of premium quality in floors etc set and jointed in next cement slurry and pointed in coloured cement over and incl 20 mm thick screed bed in cm (1:6)
S&F non skid ceramic tiles area of each tile exc 0.11 sqm but not exc 0.18 sqm in floor 7-8mm thick coloured tiles set and jointed in neat cement slurry and pointed in white or coloured to match over and incl 15 mm thick rendering in CM 1:6
M&L for glazed coloured ceremic tiles in vertical surface of size 450X300X7 mm on vertical Surfaces of wall with highlighter tile on 10mm cement mortar 1:4 set and jointed in net cement slurry and pointed in white or colour cement to match complete all as specified
S&F exterior finish wall designer wall tiles of size 450X300X7mm thick on vertical surface set and jointed in neat cement slurry and pointed in white or coloured to match over and incl 10 mm thick rendering in CM 1:4
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete.
M&L brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM 1:6 with old size bricks
Taking down cement plaster on brick wall surfaces including racking out joints hacking for key scrubbing down with water etc and removing the rubbish out of Mod Land
M&L 15 mm thick rendering fair/unfair faces of brick work on concrete surfaces finishing even and smooth without using extra cement in CM 1:6 on walls
Taking down chowkhats or frame without taking off shutters exc 1.50 sqm but n.exc 4.00 sqm
Taking down chowkhats or frame without taking off shutters n. exc 1.50 sqm
S&F powder coated aluminium window incl frame using 63 mm X 38 mm X 1.6 mm chowkhats with 48mm X 48 mm X 1.6mm openable section as in shutter including ornamental aluminium grill 8 mm dia, 75 X 95 mm aperture, 5.5 mm thick glass panes of approved make with rubber for fixing glass and including builders hardware such as aluminium handles 100 mm -02 Nos, tower bolts 100 mm 02 Nos, butt hinges SS 100 mm 04 Nos etc complete all a specified and directed by Engr-in-Charge
S&F aluminium ornamantal grill 8mm dia 75x95mm aperture complete incl U channel complete all as specified and as directed
S&F powder coated aluminium door incl frame using 96.6mm X 44.8 mm X 1.6 mm aluminium chowkhats 84.0 x44.7mmX1.6mm section vertical styles 101.60X44.88X1.6mm rails mounted on floor spring mortice lock vertical type mild steel 100 mm size (Make Godrej/Harrison) including aluminium powder coated builders hardware 02 Nos tower bolt 150 mm , sliding bolt 300 mm long 01 No, door handles and fittings complete all as specified and directed by Engr-in-Charge bottom panel with 12 mm thick laminated Novapan and top panel with 5.5 mm thick plain/colour glass fixed with snap beading /rubber gasket of suitable size and each shutter n.exc 0.95 mtr in width Make of glass:-MODI/ FLOAT/ ATUL
Dismantling boarding any descriptin , fixed in any position with screws
S&F powder coated aluminium partition n.exc 1.20 Sqm in each panel using 95.6 mm x 44.8mm x 1.6mm frame work with 12 mm thick exterior grade veneered particle boards with decorative veneers on both faces/5.50 mm thick frosted glass as directed by Engr-in-Charge including aluminium beading for fixing board (Make: GLASS Make MODI/ FLOAT/ ATUL).
S&F 18mm thick MDF board pre laminated both side fixed with screws as in storage cabinet/cub board and built in modular tables etc incl 75 mm size brass tower bolts, magnet catcher, brass hasp and staple 75 mm brass piano hinges 30 mm, brass mortice lock 65 mm two lever and hole cap incl lipping etc and sliding rail complete all as directed by Engr-in-Charge
S&F 100 mm wide Venetian blinds vertical type incl guide rail, pulling thread etc incl taking down existing pelmets/venetian blinds.
Demolition of cement concrete surface of any type in ground floor and pavings n.exc 15 cm in thickness below or above ground level & removing the rubbish out of MOD land kashmir house premises
M&L 75 mm thick PCC Subbase type C2 1:3:6 (40 mm graded aggregate) as in sub base floors pavings etc all as directed by Engr-in-charge
M&L PU Coated chequerred cement concrete tiles 30X30X25 MM thick with grey cement and pigments, set ,jointed and pointed in neat cement slurry in floors etc all as directed with Engr-in-charge
M&L for PU coated machine pressed precast conctete paver block of approved colour, shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 Grade in any tint, as in floors/pavings laid over 40 mm thick sand cushioning layer (sand shall be paid seperately) filling the joints with sand and compacting with plate vibrator complete as per IRC SP 63-2004 complete in all respect and all as specified.
Supply only sand for cushion under interlocking tiles 25 mm compacted thickness
Demolition of stone slabs and tiles or interlocking paver blocks laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. including removing the demolished material outside the MOD land.
S&F 20 mm thick granite (any type ) stone machine cut bedded and jointed with grey cement slurry and pointed with white cement with pigment to match incl cutting and polishing over 20 mm thick screed in CM 1:6 in floors
Taking down steel tubing and connections etc incl cleaning for refixing or removal from site 15 mm bore
S&F Steel water tubing , medium grade galvanized, ISI marked with all fittings laid in floors, trenches, along wall and on ceiling laid in floor complete with all fittiangs (such as bends, elbows tee, short pieces connection back nuts diminishing pieces caps and plugs unions etc of nominal bore 15 mm including taking out complete all as specified and directed
S&F Steel water tubing , medium grade galvanized, ISI marked with all fittings laid in floors, trenches, along wall and on ceiling laid in floor complete with all fittiangs (such as bends, elbows tee, short pieces connection back nuts diminishing pieces caps and plugs unions etc of nominal bore 20 mm including taking out complete all as specified and directed
S&F PVC connection 15mm bore size with PTMT nuts of length 450mm, complete, all as specified and directed.
S&F in repairs snow white vitreous china EWC single peice type 700X370X645 mm incl seat cover and flush fittings complete fixed in floor with brass screw complete Make : JAQUAR CAT Part No: SLSWHT-6851P or equivelent of Parryware,Johnson Pedder complete all as specified and directed by Engr-in-Charge
S&F in repair 15 mm bore chromium plated fancy type brass angle valve with elegant knob screwed down high pressure screwed both ends for iron pipe or for unions. Make : JAGUAR CAT Part No:KUB-35053F complete all as specified and directed by Engr-in-Charge
S&F in repair 15 mm bore chromium plated TWO way bib taps with knob to operate, complete all as specified and directed by Engr-in-Charge. Make : JAGUAR CAT Part No:KUB35041F
S&F in repair 15 mm bore chromium plated swan neck mixer tap for WHBs with elegant knob and long screw, shanks, screwed doun high pressure complete. Make : Parko Cat No. 1536 or equivelent of parko
S&F in repair CP toilet paper holder fixed to wall with CP brass screws complete Make JAQUAR CAT Part No :CAN-1153N complete all as specified and as directed
S&F in repair CP bottle trap, fixed to waste coupling complete make JAQUAR CAT Part No ALD 769 complete all as specified and directed by Engr-in-Charge
S&F in repair CP soap dish fixed to wall with brass screw complete make Jaquar Cat Part No CAN-1131N complete all as specified and as directed
S&F in repair tubular towel rails 20mm dia 60cm long of brass chromium plated fixed to wall with chromium plated brass screws and cup washers complete Make : Jaquar Cat part No AQN-7711 complete all as specified and as directed
PVC in repair connection 15mm bore size with PTMT nuts of length 450mm, complete, all as specified and directed.
S&F in repair brass CP health faucit with flexible tube
S&F towel ring (make : Jaquar Cat part No AQN7721 or equivelent fixed with CP brass screws and wooden/plastic cleats.
S&F CP brass grating 125mm size square or rounded etc fixed with cement complete all as specified and as directed
Dismantling water tanks exc 500 ltr and n. exc1000 ltr and removal from site complete all as specified and directed.
S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position including Tank Nipple, 20 mm bore ball brass valve and with union (Two Nos each), fittings complete all as specified and directed.
S&F in repair oval type wash hand basin vitreous china white counter basin of size 540x480mm including making good the surface/joint with white cement complete all as specified make CERA cat part No 1009 or equivalent
S&F in repair cast iron 75mm bore soil waste pipe in any length with or without ears with cement joint laid in trenches and floor
S&F in repair cast iron 100mm bore soil waste pipe in any length with or without ears with cement joint laid in trenches and floor
S&F in repair cast iron floor trap for 75mm outlet pipe including nointing to waste pipe in cement concrete type B-1 (1:2:4)
S&F in repair sinks made of stainless steel lmm thick kitchen or laboratorywith plugs, washers and wastes including bedding in cementmortar on to dwarf wall orincluding fixing cantilever bracketsand connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed
S&F 7 mm thick PVC solid floor laminates WPC core type fixing with click lock installation including angle at stair case corner stuck on inner frame work of 5mm thick rigid foam sheet base. The sheets should have a groove of 6 mm width and 2 mm depth for sinking the head of screw used to fix the sheets . The PVC sheets to be fixed to the all using 65 mm long MS screws through the groove in the sheets by using PVC fastners. etc all as directed and approved by Engr-in-charge. Make:- REHAU or its equivalent as approved by GE Note:- (a) Work for fixing of floor laminates shall be got executed through manufacturers authorised applicators only under the close supervision of their technical staff. (b) The entire qty of floor laminates and their allied ancillaries shall be procured directly from the manufacturer or their authorised dealer only.
Preparation of new or previously untreated wooden surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of anti termite treatment chemical.
S&F second class soft wood timber scantling as in timber framed work.
S &F in repair block boards 18/19 mm thick Grade II interior grade commercial type with decorative face veneer on both faces fixed with screws incl 6mm thick teak wood lipping as in cub boards incl builders hardware fittings complete all as specified and directed. Make : Kitply,Ecoboard, M/s Green Ply.
M&L vitrified ceramic tiles of light shade 9-10 mm thick(Square/Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white of coloured cement to match over and including 15 mm thick screed bed in cm 1:6.
M&L Cement concrete 1: 2 : 4 type B-0 ( using 12.5mm graded crushed stone aggregate) 25 mm thick as in sub floor, finishing surfaces of concrete topping even and rough to receive the floor topping.complete all as specified
Dismantling steel sheeting plain (corrugated semi corrugated etc) sheet in roof coveriing and other cladding work
S&F Pre-painted galvatume aluminium zinc coating GI based profile steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L Washed stone grit plaster on exterior walls in two layers , under layer 12 mm cement [laster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool , applying cement slurry on the under layer @ 3 kg of cement per square metre , top layer 15 mm cement plaster 1:1/2:2 (1 cement:1/2 coarse sand: 2 stone chipping 10 mm nominal size ) (add 1/2 part marble powder) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (payments for providing grooves shall be made separately) ( colour of marble chips and marble powder shall be approved by engr-in-charge )
M&L forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engr-in-charge the groove shall be finished with bituminous paint all as specified and directed
Supply only integral water proofing compound
S& F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
S&F 10 mm thick coloured polycarbonate multiwell sheet manufactured from high quality, UV stabilzed resins in roof covering incl necessary fittings & fixtures like aluminium strips coach screw and washers etc with silicon joints filler for fixing complete of any colour all as specified and directed by engineer in charge
M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying tow coats of synthetic enamel paints over one coat of red oxide primer
Taking down carefully existing copper /aluminum point wiring (Light, fan, socket or power) complete including fittings and fixtures such as switches ceiling roses socket, regulator etc. and making good disturbed surfaces of walls, floors etc to match with the existing surface/ finishes complete all as specified & directed.
M&L for Point wiring with 1.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/neutral and connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors etc, and also incl suitable modular bottom sunk type pressed steel terminal box and suitable modular top cover with frame and No of modules for the following :-make for cable- RR Kabels, Havells, Finolex. make for conduit- Kalinga, Plaza,
One light/fan/bell point controlled by one, one way switch.
One three pin socket outlet 5 Amp controlled by one, one way switch on same board
One three pin socket outlet 5 Amp controlled by one, one way switch on independent board
M&L for Point wiring with 2.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of 1.5 sqmm connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors etc, and also incl suitable modular bottom sunk type pressed steel terminal box and suitable modular top cover with frame and No of modules for 15 Amp socket out let on independent board.
Supply and fix switch modular 6 Amps 1 module 230 Volts one way
Supply and fix modular switch 1 way 16 Amps 1 module 230 Volts
Supply and fix modular socket , 6 Amp 2/3 pin combined 230 Volts
Supply and fix modular socket , 16 Amp 2/3 pin combined 230 Volts
Supply and fix modular type fan regulator electronic step type 250 Volts single phase 2 module,120 watts connecting suitable for ceiling fan 1200 /1400 mm sweep complete.
S&F ceiling fan 1200 mm sweep complete with down rod etc complete all as specified and directed. Make:- Havells Bajaj/ Crompton Graves/ Usha.
S&F wall mounted 450 fan mm sweep, iron body complete with all acessories etc complete all as specified and directed. Make:- Almonard/Havells/Bajaj.
Supply and fixing exhaust fan of 300 mm, ms body sweep, single phase 230V AC, 900 RPM, light duty with louvered shutters including mounting frame and connecting the fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sq mm not less than 0.5 mtr long for connections complete all as specified. Make-Havells/Crompton/Usha/bajaj
S & F in replacement LED Ligtht fitting revolutionary anti glare luminaires immaculate soft 33 watts 2x2 Ultra 4000 K modern recess mounting luminaire suitable for armstrong/grid/POP ceiling complete with separate electronic driver & high brightness SMD LEDs, 33 W LED 4000K lamp type. Make:- CRC010R033HP57UGR Wipro , Phillips Cat part No- Havells Cat Part No LHEWEJP7PL1W034/Phillips
S & F in replacement LED tube Ligtht fitting 20 watts surface an wall mountednLED batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Make:- Havells Cat Part No. LHEWEBP5IN1W020 or equivalent in Wipro/Phillips/Bajaj
S&F in replacement sub main wiring with two runs PVC insulated unsheathed FRLS stranded copper conductor cable of size 4 Sqmm alongwith one run of PVC insulated unsheathed stranded copper conductor cable of size 4.0 sqmm as earth wire connected to earth dolly fixed on surface of wall/ceiling/in existing concealed conduits complete all as specified and directed. Note :- Two run of 6 sqmm copper conductor cable,one run of 6 sqmm copper cable and one run of PVC conduit shall be measured as one unit length.Work includes chases cutting work if requiredMake- RR Kabels/ Havells/ Finolex
Sub main wiring with two single core 6 sqmm copper conductor PVC insulated multistranded unsheathed FRLS cable drawn in and including ISI marked 25 mm dia medium grade PVC conduit concealed in wall surface/ceiling including 6 sqmm PVC insulated unsheathed multistranded copper conductor, FRLS cable as earth wire complete as directed. Note :- Two run of 6 sqmm copper conductor cable,one run of 6 sqmm copper cable and one run of PVC conduit shall be measured as one unit length.Work includes chases cutting work if required Make- RR Kabels/ Havells/ Finolex
Taking down U/S sub main wiring of any type/size complete all as specified and directed
supply and fix MCB SP 5 to 30 Amps to KA rupturing capacity, IS-8828 marked.
S&F MCB DBs single pole with neutral sheet metal enclosures double door type 8 way, 240 Volts, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete with out MCB and with enclosures blank plate for unused way suitable for 8 way.Make-Legrand/Schneider/ABB
MCB SPN 240 Volt of capacity 32 to 60 Amp rating, "B" Series complete all as directed. Make-Legrand/Schneider/ABB
S&F sheet metal enclosure 2-in-1 3 pin metalic socket and plug top with plug socket and MCB 20 Amp SP. Make-Legrand/Schneider/ABB
M&L for shifting of ACs(indoor and outdoor unit) of any capacity to specified locaton , cutting of roof slab, drawn through and fixed /laid concealed in walls/ceilings, making good to disturbed surface of wall/floor etc to match the existing surface/ finishes all as directed, incl rectification minor defects and make the equipment functional complete all as directed.
Supply and Fixing in replacement of synthetic rubber tube insulation of thickness 9 mm & Internal Diameter - 13 mm (1/2")for refrigerant copper piping of split AC units. Make Supreme/Gulf-o-flex/Superlon.
Supply & charging as top-up of gas refrigerant R-22 or as existing No to split/window type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
S&F copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for ACs.
S&F copper tubing heavy duty inner dia 13 mm (1/2") for refrigerant for ACs.
S/F non metallic PVC conduit of size 25 mm dia including of tees, bends & elbows, reducers etc complete.
Supply and fix Modular metal flush gang Boxes 6 module for housing electrical accessories and recessed into a wall or ceiling shall be of sheet steel or cast iron as indicated and shall conform to IS 14772-2000. Complete all as specified and as directed by Engr-in-Charge
Supply and fix Modular metal flush gang Boxes 3 module for housing electrical accessories and recessed into a wall or ceiling shall be of sheet steel or cast iron as indicated and shall conform to IS 14772-2000. Complete all as specified and as directed by Engr-in-Charge
Supply and fix modular face plate 6 module cover with frame for fixing on sunken boxes and for mounting modular type switches , sockets, fan regulators etc. Complete all as specified and as directed by Engr-in-Charge
Supply and fix modular face plate 3 module for fixing on sunken boxes. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down ceiling/wall mounted/exhaust fan, after dis-connecting cable end, regulator, dismantling of blades and refixing of the ceiling fan taken down after painting and refixing the same. complete all as specified and directed. Note: Contractor has to ensure safety of ceiling fan installed and in case of any theft Contractor shall be held responsible
Supply and fix in replacement MCB DBs single pole 12 way with neutral sheet metal enclosures double door type, 240 Volts, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete with out MCB and with enclosures blank plate for unused way suitable for 12 way. Make-Lrgrand/Schneider/ABB
S&F plain, glavanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275.
sony engineering works
B Kumar and Co
BEHAL TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .