| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.2 L+₹37,691.06 (1.15%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹34.6 L+₹1.8 L (5.49%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹34.9 L+₹2.1 L (6.33%)Rejected-Finance MALANCHA ROAD KHARAGPUR 721304 DIST WEST MIDNAPORE WEST BENGAL | KHARAGPUR | WEST MIDNAPORE | WEST BENGAL | 721304 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹37.0 L+₹4.2 L (12.7%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
3 Feb 2024, 6:00 pmClosed
MAJOR M K YADAV,
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
ADDITION/ALTERATION OF CEO COMPLEX WITH PARKING AND EATHING PIT BASE COVER AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2024_MES_636038_1
C/8931/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹87,000
Yes
8 Mar 2024
6 Jan 2024
5 Feb 2024
6 Jan 2024
3 Feb 2024
20 Jan 2024
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Surface excavation in hard/dense soil not exceeding 30cm deep and averaging 15cm deep and getting out complete including removal to distance exceeding 250m but not exceeding 1000m all as specified and directed.
Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed.
Materials and Labour for, broken stone or boulder hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface , complete all as specified and directed.
M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts or floor , punned down to desired thickness complete all as specified and directed. (Note: For payment purposes only punned down thickness of sand shall be measured )
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief.
S&F aluminium powder coated of approved colour door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
M&L for 12mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work with and including all connected fitting and acesssories complete all as specified and directed
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
Materials and Labour for reinforced cement concrete M-20 nominal mix in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete ,complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-20 nominal mix in columns; pillars; piers; posts; struts etc,complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
Supply and fix mild steel TMT bars 5 mm dia. and over up to and including 10 mm dia. in stirrups, spacers, binders etc. cut to length, bend to shape required including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces ,cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
Supply & Fixing for rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250 ) quality-A complete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brasshandles etc., as specified, erected in position and securing runners with holdfasts and brackets with and including all connected acessories, complete all as specified and as directed
M & L for ceramic fully vitrified tiles, coloured ceramic floor tiles (group B Ia), 600 mm X 600 mm X 9-10 mm in floors laid with and including over 20 mm thick screed bed or bedding layer in cement mortar(1:4) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed.
M & L for ceramic fully vitrified tiles, coloured ceramic floor tiles (group B Ia), 600 mm X 600 mm X 10 mm in skirting's/ vertical surfaces with and including laid over 10 mm thick backing coat in cement mortar(1:3) set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
M&L for machine cut kota stone slab flooring 18-20 mm thick laid over cement screed base and jointed and pointed , grinding and polishing to obtain mirror finishes over and including 20 mm thick rendering in CM 1:4 complete all as specified and directed.
All as per item No.34.00 above but as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with grey cement and pigment cement over and including 10 mm thick screed bed in CM 1: 3 complete all as specified and directed.
Material and Labour for chequered ceramic tiles, coloured, 10-12 mm thick (square/rectangular) area of each tile exceeding 0.06 Sq M but not exceeding 0.11 Sq M, conforming to IS 4457-2007, on floors, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour,complete all as specified and directed.
M & L 75 mm thick plain cement concrete M15(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as hadstanding/subase/Plinth protection complete all as specified and as directed.
M & L 100 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as as in sub base floor/paving/hardstanding complete all as specified and directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as as in sub base floor/paving/hardstanding complete all as specified and directed.
M & L 100 mm thick plain cement concrete M15(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as as in sub base floor/paving/hardstanding complete all as specified and directed.
Materials and Labour for Forming contraction (dummy) joints 75mm deep x 10mm wide filled with sealing compound complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - Note : Water proofing compound deemed to be inclusive rates
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated any approved profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall ,over and including with a coat of 1.5 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified.
M & L for applying Two 100 % Acrylic Exterior Emulsion paint in camouflage pattern (Three colours as approved by GE) (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand over a coat of exterior wall primer on new concrete/wall surfaces up to 18 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L 4mm thick ACP board (Aluminium composite panel), exterior grade, (approved colour) fixed with aluminium tapperd clip to aluminium frame work all complete all as specified and as directed
S&F Vitreous china urinal partition white of minimum size 310x700 mm with and including all connected acessories complete all as specfied and directed
M&L Brick work with flyash bricks old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:4 all complete all as specified and directed.
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
S&F point wiring with 1.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010 , ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as per existing specification without any extra cost One light/Fan point controlled by one 5 Amps switch one way complete
All as per item 54.00 here in before but One 3 pin 5 amp switch socket combination point on independent board with other switches complete all as specified and directed by EIC.
All as per item 54.00 here in before but power point wiring with 2.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010, ISI marked , PVC insulated unsheathed cable & including PVC casing caping of 25 mm wide , including all accessories casing caping complete with PVC 2.5 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point.complete all as specified and directed by EIC.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
S&F switch piano flush type single pole,5 Amp. AC, 230 V one way complete all as specified and directed by EIC.
S&F stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed by Engr-in- charge.
S&F Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.
S&F switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed by EIC.
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S&F LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2400, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed.
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4000, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.
S&F in repair PVC casing caping of size 38X16mm exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking out old u/s all as specified and directed by Engineer in charge.
Supply Installation, fixing PVC Raceway fitting with GI cover of 1.5 mm thickness ( GI rectangular conduit) with fittings, compatible with Cat 6 structured cabling system to be laid in wall in concealed or in underground in floor (for screed floor) complete of size 50 mm (width) x 38 mm (height) , single compartment with its mounting accessories, length of raceway cut to size as per site requirement complete all as specified and directed by Engineer in Charge Make Legrand Cat Part No. 689510 or as equivalent in L&T / C&S. Note:(i) Raceway shall be in standard length of 2.44 mtr. (ii) Cost of chase cutting in wall for fixing of raceway on wall in concealed and make good to be included in unit rate of item. No extra cost will be paid in ths account.
Supply and Fix, Heavy Duty Exhaust Fan, 300 mm sweep, 1400 RPM, Single Phase, 230 V, 50 Hz, all as per Model “Turbo Force” of Make ‘Havells’ or equivalent Model of Make ‘Bajaj’ /’Cromptron Greaves’/’USHA’ and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan with and including taking down existing old unserviceable exhaust fan any type and model, shall be deposited MES store by the contractor and received voucher to be obtained and submitted alongwith RAR/Final Bill complete all as specified and directed by Eng in Charge.
Cutting openings, through brick walls built in cement mortar or cement lime mortar, for exhaust fan and other openings or enlarging existing openings, superficial area exceeding 0.16 Sqm but not exceeding 0.25 Sqm, making good distrubed portion, grouting of suitable bolts with nuts & washers for fixing exhaust fan,rendering 15 mm thick plaster in CM (1:4) around jambs of opening, complete all as specified and directed.
Supply and Hanging, ISI marked ceiling fan, 1200 mm sweep with down rod, canopy, fan blades,safety wire and connected accessories, BEE 5 Star Rated, Service value not less than 7.00 all as approved ADG(NEI) group I make ’, and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan with and including taking down existing old unserviceable fan any type and model, shall be deposited MES store by the contractor and received voucher to be obtained and submitted alongwith RAR/Final Bill complete all as specified and directed by Eng in Charge.
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4200, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L70 and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. .
S&F point wiring with 1.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010 , ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including 20mm dia rigid non metalic PVC conduit, including all accessories as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as per existing specification without any extra cost One light/Fan point controlled by one 5 Amps switch one way complete
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.6 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick 2-nos mild steel nuts, bolts incuding painting two coats of aluminium paint over a coat of primer all as specified and directed by Engineer In Charge. including taking down old unservieable complete all as specified and directed.
Taking down ceilling fans/Exhaust fan, sealing cable end, including painting of fan with systhetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc. and repositioning & hanging ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as directed by engineer in charge.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & Fin repair sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. Note : (i) MCCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Taking down existing outdoor and indoor unit of split AC machine capacity 1.5/2Ton including existing accessories like copper pipe, water droping pipe etc and refixing the same unit at same location /other as directed after comprehensive servicing for Split Type Air Conditioner of any make by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration ncluding cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil and including necassary fixing arrangement complete (indoor unit at suitable place and hight inside the room and outdoor unit at suitable place outside the room) including metallic bracket as per OEM recommendation with and including fixing bolts, anchore fashner for fixing bracket for mounting outdoor unit, insulated piping,making all electrical connections etc from Power supply socket to AC unit by providing suitable size PVC insulatated sheathed copper conductor cable size not less than 4 Sqmm x 3 core, complete all as specified and as directed.
S&F LED recessed panel ceiling light fittings 40/36 watt LED 1x4 FT extruded aluminium housing. HET diffuser for uniform homogeneous, LED wattage of minimum 3 watt each and Maximum 5 watt each, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear of size 1200 mm x 300 mm , with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white, including making electric connection from source with PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and fixing light in celing by all providing all arrangements complete all as specified and directed by Engr-in-Charge.
Supply and Installation, fixing, testing and commissioning of Split Air conditioner unit of 1.5 TR capacity of indoor and outdoor unit white colour, electric driven, Single Phase, 230 Volt , 50 Hz and 5 Star BEE rating, inverter AC, having rotary compressor, copper tube condenser with R-32 refrigerant, cooling capacity above 5280W, dehumidification including necassary fixing arrangement complete indoor and out door unit at suitable place including heavy metallic bracket, fastners for outdoor unit and wrapping of PVC insulation thermal tape for copper insulated pipe includig tie, watering pipe approx 3 mtr, making all electrical connections, distrubed surface match with existing surface etc, including taking down old u/s AC complete all as specified and directed . NOTE : 1. Instalation of New AC will be carried out only through OEM or authorized agencies at site.
Supply & fixing MS pipe (with down rod, canopy), heavy duty as per OEM specification for hanging ceiling fan including nut bolts, and necessary fixing arrangement complete all as specified and as directed.
CLASSIC CONSTRUCTION AND SUPPLIERS
Kalpana Traders
T K Construction
SHARMA ENTERPRISES
NATIONAL CONSTRUCTION CO
Guru Charan Mahata
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .