Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 CrAccepted-AOC | ₹5.7 Cr | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹5.7 Cr+₹2.3 L (0.40%)Rejected-Finance | ₹5.7 Cr+₹2.3 L (0.40%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹5.8 Cr+₹8.7 L (1.53%)Rejected-Finance | ₹5.8 Cr+₹8.7 L (1.53%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹5.9 Cr+₹21.3 L (3.73%)Rejected-Finance | ₹5.9 Cr+₹21.3 L (3.73%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹6.0 Cr+₹24.7 L (4.32%)Rejected-Finance | ₹6.0 Cr+₹24.7 L (4.32%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
18 May 2022, 6:00 pmClosed
Chief Engineer Lucknow Zone
HQ Chief Engineer Lucknow, 17 Cariappa Road, Lucknow Cantt
PROVN OF DEFICIENT ACCN INCLUDING GUARD ROOM AT HQ MUPSA CAMP LOC AT LUCKNOW
2021_MES_466897_2
CELZ/LKO/T-05 OF 2021-22
Open Tender
Civil Works
Lump-sum
540 days
LUCKNOW
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (Project) Lucknow
₹5.5 L
16 Aug 2022
30 Mar 2022
20 May 2022
30 Mar 2022
18 May 2022
4 May 2022
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Sewage Disposal)
Total amount of Sch 'A' Part VI (Road, Path & Culvert )
Total amount of Sch 'A' Part VII (Area Drainage)
Total amount of Sch 'A' Part VIII (Security Wall & Gate )
Total amount of Sch 'A' Part IX (External Water Supply )
Total amount of Sch 'A' Part X (External Electrification )
Total amount of Sch 'A' Part XI (Rain Water Harvesting )
Total amount of Sch 'A' Part XII (Refrigerator, Water Cooler & Desert Cooler)
Total amount of Sch 'A' Part XIII (Solar Water Heater )
Total amount of Sch 'A' Part XIV(Conduit for Telephone /TV)
Total amount of Sch 'A' Part XV (Dismentling /Demolition )
Sch 'A' Part - XVI (Miscellaneous Items) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S& F of jet with flexible lead & brass nozzle 15 mm bore pipe complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost..
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insualted and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete one 5 pin 05/15 Amps switch socket out let on an independent board with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area) ,ISI marked, multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and MS conduit in roof/floorslab excluding flush metal GI boxes complete,including 1.5 Sqmm,FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light/Fan/Exhaust Fan point controlled by one modular switch with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate,outer plate, top cover in all accessory, including 1.5 Sqmm PVC, FRLS unsheathed FRLS cable 1.5 sqmm (nominal area) ISI marked multistranded copper conductor single core for earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-Red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One 5 Pin 6 Amp modular socket outlet point on an indepndent board with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate,outer plate, top cover in all accessory, including 1.5 Sqmm PVC, FRLS unsheathed FRLS cable 1.5 sqmm (nominal area) ISI marked multistranded copper conductor single core for earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-Red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One 5 Pin 6 Amp modular socket outlet point on same board with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate,outer plate, top cover in all accessory, including 1.5 Sqmm PVC, FRLS unsheathed FRLS cable 1.5 sqmm (nominal area) ISI marked multistranded copper conductor single core for earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-Red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One 5 Pin 16 Amp modular socket outlet point on an independent board with PVC insualted and unsheathed FRLS cable 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate,outer plate, top cover in all accessory, including 2.5 Sqmm PVC, FRLS unsheathed FRLS cable 2.5 sqmm (nominal area) ISI marked multistranded copper conductor single core for earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-Red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Supply and fixing of blanking plate for one module complete all as specified and directed. Make :- Legrand(Arteor)/Havells Crabtree/Anchor Roma Plus)
Supply and fixing telephone socket Modular type complete with all acessories complete all as specified and directed.
Supply and fixing Switch flush type 5/6 Amps single pole two way complete all as specified and dierected..
Supply and fixing LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (14W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
S&F LED type mirror light 10/11 watt with white powder coated aluminium housing with integrated electronic driver .complete all as specified and directed. Make : Philips/Bajaj/Crompton
S&F LED light 10/12 watt with white powder coated aluminium housing with integrated electronic driver of complete all as specified and directed. Make :- Cat part No INTEGRANEOSURFACEDLS 10 W LED857S of Havells/ Cat part No SM250C LED 12S-6500PSU WH of Philips /Cat part No LCDSPLNR-12-WW of Crompton
S&F adjustable type LED study lamp with deffuser light 10 Watts recessed/Wall mounted LED wall min 120 Lum/Watts washers, tilled 70 degree outwards and swivels 360 degree to offer the best lamination on the wall/floor/retailer display all as specified and directed. MakePhilips cat part No 48042 3 Watt LED Bed side light or Cat Part No LHFHDNE 1 TN 1G020 of Havells or equivlent cat part of Cropton
Supply and fixing fullglow and fully diffused recessed mounted 2'x2' LED luminaire with high transmitive diffuser suitable for indoor spaces complete all as specifed and directed. Make : Phipips cat part No RC380B LED36S-6500 G4L60 W60 PSD OD/Crompton Cat part No. ICTRF7-36-WW/ Havells cat part No LHFHDNE1TN1G020 .
Supply and fix decorative wall mounting Engment light chrome finish fixture with textured glass including 11 watts Red and Green LED lamp complete all as specifed and directed. .Make Havells cat part no LHFOFDC1TZ1C040 or philips
Supply and fixing Ceiling fan 1200 mm sweep single phase 230V AC, ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection complete all as specified. Make Bajaj model Electra 50 or technocommercially equivalent in Philips/Crompton.
Supply and fixing Ceiling fan 1400 mm sweep single phase 230V AC, ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection complete all as specified.. Make Bajaj model Electra 50 or technocommercially equivalent in Philips/Crompton.
Supply and fixing Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 300 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor complete all as specified and directed. Make- Usha/Baja/havells/CG.
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 380 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model no Supreme Dlx /havells/CG
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model no Supreme Dlx /havells/CG
MCCB 4 pole ,415 V ,AC fixed type 125 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB 4 pole ,415 V ,AC fixed type 100 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. Note: MCCB shall be measured and paid seprately under respective item.
Supply and fixing MCB DB 12 WAY single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked all as specified and directed
Supply and fixing MCB DB 8 WAY single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked all as specified and directed
S&F MCB TP 63 Amps 'B" series,,10 KA 240 Volts, AC complete all as specified and directed.
MCB single pole 6 to 32 Amp rating 'B' Series, 10 KA 240 volt complete all as specified and directed.
MCB single pole and neutral 40 Amps rating 'B' Series, 10 KA 240 volt complete all as specified and directed.
Submain wiring with two single core 2.5 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 2.5 sqmm copper conductor, one run PVC conduit and one run of 2.5 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Submain wiring with two single core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Submain wiring with four single core 10 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Four single core 10 sqmm copper conductor, one run PVC conduit and one run of 10 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x6 mm thick buried directly in ground (earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 25mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 Type B-1 reinforced with 8mm dia TMT bars @ 8mm c/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed.
SEWAGE DISPOSAL Providing and laying 150mm internal diameter pipe of Class-SN8 Structured Wall polyethelene Piping systems (Pipe with online/offine coupler and elastomeric sealing ring) with non-smooth External Annular Corruqated and smooth Internal surface (Double Wall) for non-pressure underground Sewerage & Drainage application conforming to IS:16098:2013 including all materials, labours, T&P required for proper completion of work complete all as specified and directed.
Providing and laying 200mm internal diameter pipe of Class-SN8 Structured Wall polyethelene Piping systems (Pipe with online/offine coupler and elastomeric sealing ring) with non-smooth External Annular Corruqated and smooth Internal surface (Double Wall) for non-pressure underground Sewerage & Drainage application conforming to IS:16098:2013 including all materials, labours, T&P required for proper completion of work complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of brick masonary valve pit chamber of size 900mm x 900 mm x 900mm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
Construction of brick masonary valve pit chamber of size 1050mmx1050 mm x1050mm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
Boring of holes up to 150 mm bore under road crossing, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine complete all as specified and directed.
Taking up/Dismantling of CI/GI pipe line including valves of 100/80 mm dia including necessary earth work in any type of soil complete all as specified and directed.
Taking up/Dismantling of GI pipe line including valves of 50/40 mm dia including necessary earth work in any type of soil complete all as specified and directed.
Taking up/Dismantling of GI pipe line including valves of 25/20 mm dia including necessary earth work in any type of soil complete all as specified and directed.
Dismantling of valve pit of any size complete all as specified and directed.
Laying only GI tubing of any size up to 50 mm dia on new route including fitting suitable size complete all as specified and directed. Note :- Excavation, Returning filling shall be measured and paid sepratly under Sch 'A' Part II in respectiove item.
Laying only GI tubing of 50 to 80 mm dia on new route including fitting suitable size complete all as specified and directed. Note :- Excavation, Returning filling shall be measured and paid sepratly under Sch 'A' Part II in respectiove item.
EXTERNAL ELECTRIC SUPPLY Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 6 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 185 Sqmm 3.5 core complete all as specified and directed.
Supply & fixing Integral LED street luminaire 70/75 watt comprising of PDC housing enclosed with toughened glass cover suitable for & including 32/40 mm OD GI Pipe not less than 1.2 mtr long bent to shape bracket ingress protection 66 Complete all as specified and directed. Make : Surya cat part No SLE UL 72 W IP 66 LXN or Philips/CG/Havells equivlant make as approved by GE.
Supply & fixing polycarbonate junction box of size 250x200x150 mm with 01 No MCB SP 6 Amp,02 nos aluminium bus bar of size 25x3 mm fixed on porcelain support with hinged cover and locking arrangement fixed to pole complete all as specified and directed.
Supply & fixing Solar street light system smart integrated solar street light with buillt in Mono Crystalline Panel lithium Ion Battery ( LifePO4) MPPT charge controller and PIR Sensor with Colour Temp 6000-6500K 20 Watt without hybrid switch 40 Wp with 21 Ah 3 day backup including galvanised steel pole installation commissioning including materials and labour for masonary work complete all as specified and directed.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1 using (20 mm graded stone aggregate), mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 15 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, erecting and installation of steel tubular, swaged, pole of overall length 9 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-31 conforming to IS-2713-1980 for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be deemed to be included in the unit rate.
Supply and fixing high power LED flood light 60 Watt IP 66 Energy saving & environmental frindly long life Versatile pressure dia cast aluminium road way luminaire with high power LEDs as light source and electronic driver fixed on pole/wall alongwith service bracket as per sample, clamps, nuts, bolts and washers as directed including electric connection with 1.5 sqmm multistranded twin core aluminium cable PVC insulated from junction box to light fittings laid in in pole/ service bracket complete all as specified and directed.
Supply and fixing weather junction box of Size nearest 328 mmx 239 mmx129 mm, outdoor type made out of thermo polycarbonate to accmmodateed 04 nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and tringular locks shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete including fixing of thimbles and cable gland complete all specified and directed.
Supply and fixing MCCB 160 Amps 4 Pole, 35 KA with suitable enclosure for incoming taping point complete all specified and directed.
(a) Aluminium bus bar, 3 Nos for phase (R,Y,B) of rating 400 Amp and 01 for neutral raiting 200 Amp mounted on heavy duty rubberised/porcelain support -04 Nos .
(b) INCOMING: MCCB 4 pole 160 amps Icu=35KA, Ics =100% of Icu with thermal magnetic release and adjustable overload (min 70% to 100%) -01 no
(c) OUTGOING : MCCB 4 Pole 100 Amp 35 KA 440 V , 50 HZ- 01 No
(d) MCCB 4 Pole 63 Amp 25 KA 440 V , 50 HZ- 02 Nos
(e) MCCB 4 Pole 32 Amp 16 KA 440 V , 50 HZ- 02 Nos
(f) MCB SPN 20 Amp , 230 Vols , 50 HZ- 01 No
(g) Multifunctional Energy mtr - 1 No for each outgoing and incoming.
(h) RYB LED indicating lamp -01 Set (set of three)
(i) MS work incl angle iron frame and PCC work
(j) Street light timer switch
(i) Street light timer MicroRex W31 Su/Wi-Weekly time switch analog time switches Manual switching ON/automatic/OFF Horly/daily/weekly switching dail with captive segments clock precision + 5 min for the daily time switch 10˚ to 50 ˚ C opertingtemprature Make :- Legrand uitable for operation of street light with necessary switchgear such as contactor,timer inch necessary internal wiring.
(ii) MCB TPN 16 Amp 10 KA
(iii) Toggle switch 16 Amp
(iv) Conductor suitable size
(v) Wiring of panel complete all as specified and directed.
Dismantling & Taking out LT UG cable 1100 Volts of any size complete all as specified and directed.
Dismantling of old U/S GI wire of any size complete all as specified and directed.
Dismantling of old U/S earthing complete all as specified and directed.
Dismantling of old U/S house services bracket complete all as specified and directed.
Dismantling of LT panel of any type and any size complete all as specified and directed.
Dismantling old U/S MCB DB and MCB/Main switch complete all as specified and directed.
RAIN WATER HARVESTING Plain PVC pipe 100 mm dia bore as per IS 12818 including lowering & jointing complete all as specified and directed.
Screened PVC pipe 100 mm dia bore as per IS 12818 including lowering & jointing complete all as specified and directed.
Bore/Drilling 200 mm dia size duct bore through any kind of soil/strata by direct rotary method up to and including 90 mtr deprh complete all as specified and directed.
Reaming of bore upto 300 mm (only for recharge well) pilot bore in any ind of soil/strata including hard stone /boulder by means of direct rotary method up to and including 60 RM depth each below ground level complete all as specified and directed.
Pea Gravel packing for trail bores of size to be designated by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed.
Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/ dirty water complete all as specified and directed.
PVC end cap for 100 mm bore pipe complete all as specified and directed.
Plain PVC bend 87.5˚for 100 mm bore pipe with nylon wiremesh for to covering one end complete all as specified and directed.
Piezometer (Steel Tape 25 mm wide and 50 metre long with plumb) complete all as specified and directed.
REFRIGERATOR, WATER COOLER,DESERT COOLER Supply and fixing of Refrigerator of capacity 190 to 210 liter, electric driven, single phase, 230 volts AC 50 Hz 3 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Supply and fixing of Refrigerator of capacity 250 to 310 liter, electric driven, single phase, 230 volts AC 50 Hz 3 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Supply and installation of desert cooler electric driven motor heavy duty with operating regulator ( single phase) having nominal air flow capacity of 4000 Cum per hours and gauge of sheet 1.6 mm thick grill type front side up and down,horizontal and vertical adjustable PVC grill, three side fince type cabinet of min thickness 1.6 mm with handle floor provision including water pipe connection wiith PVC pipe connection having brass coupling nuts at other ends and PVC float valve and other necessary fittings and electric plug connection with and including plug top 5 Amps complete all as specified and directed.
Supply and installation of Voltage stabilizer of capacity 1.00 KVA for automatic operation single phase naturally air cooled indoor type & designed for input voltage between 170 volts to 250 Volts with out put voltage stablized at 230 Volts with accuracy of + 2.5 % complete all as specified and directed.
Supply and installation of Voltage stabilizer of capacity 5.00 KVA for automatic operation single phase naturally air cooled indoor type & designed for input voltage between 170 volts to 250 Volts with out put voltage stablized at 230 Volts with accuracy of + 2.5 % complete all as specified and directed.
DISMANTLING/DEMOLITION Dismantling of Urinal any type with fitting complete all as specified and directed.
Dismantling of WC any type with fitting complete all as specified and directed.
Dismantling of flushing cistern with fitting complete all as specified and directed.
Dismantling of Wash hand basin any type with fitting complete all as specified and directed.
Dismantling of looking mirror complete all as specified and directed.
Taking down of Towel Rail complete all as specified and directed.
Taking down of old unserviceable copper/aluminium point wiring for light, fan, socket or power complete all as specified and directed.
Taking out of old unserviceable copper/aluminium submain wiring of various size complete all as specified and directed.
Taking out of old unserviceable tube light fitting of any type/ description complete all as specified and directed.
Taking out of old unserviceable holder of any type complete all as specified and directed.
Taking out of old unserviceable switch socket 6 Amp complete all as specified and directed.
Taking out of old unserviceable switch socket 15 Amp complete all as specified and directed.
Taking out of old unserviceable ceiling rose complete all as specified and directed.
Taking out of old unserviceable fan regulator complete all as specified and directed.
D.M.BROTHERS
Gambhir Constructions
SHRIPATI INFRASTRUCTURES PVT LTD
SEAHAWK ENTERPRISES PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .