Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹24.0 L+₹65,180.50 (2.79%)Rejected-AOC 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L2 | Rejected-AOC AOC | |
| 3 | L3₹25.5 L+₹2.1 L (9.15%)Rejected-AOC AZARA GUWAHATI ASSAM 781017 | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-AOC AOC | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to non-enlistment requisite |
Tender Value
Refer Docs
EMD Value
₹49,000
Closing Date
25 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Borjhar
HQ CWE (AF) Borjhar, Military Engineer Services, PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele 0361 2841626
PROVN OF 02 x 125 KVA VOLTAGE STABILIZERS AT AFS BORJHAR
2023_MES_634576_1
CWE(AF)/BOR/TOKEN-36 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Borjhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Borjhar
₹49,000
Yes
26 Mar 2024
27 Dec 2023
1 Feb 2024
27 Dec 2023
25 Jan 2024
11 Jan 2024
Amount
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point , complete all as specified and as directed.
Supply and spreading dry sand of approved quality for cushioning of UG cable laid in trenches 8 cm deep before laying the cable and 15 cm thick after laying & streching the cable complete all as specified and directed. (NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for).
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
Supply and fix GI pipe light grade 100 mm bore for cable protection including all fittings laid in trenches or fixed on pole with suitable clamps complete all as specified and directed.
Supply and fix GI pipe light grade 80 mm bore for cable protection including all fittings laid in trenches or fixed on pole with suitable clamps complete all as specified and directed.
M&L for auguring under road, pavement, hard standing, runway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI pipe of 100 mm and 80 mm bore complete all as as directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 185 sqmm 3.5 core (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 120 sqmm 3.5 core (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core PVC/XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and as directed. Make: Raychem/3M/M-Seal
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core PVC/XLPE armoured aluminium conductor cable of size 185-300 sqmm complete all as specified and as directed. Make: Raychem/3M/M-Seal
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, Cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 sqmm to 95 sqmm.Make: Raychem/3M/M-Seal
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 m depth below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip 20x3mm mm dia by means of brass nut. bolt, washer & protection pipe for earth strip from the earthing plate to the equipments/Panel, (40 mm bore, Light grade), watering pipe from plate to earthing pit (20 mm bore, medium grade), funnel with wiremesh. The earthing pit made up of PCC 1:3:6 type Cl and pit cover made up of 40 mm thick pre cast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work as shown in SSR Part 1 plate no 5 as specified & directed. Note:- (i) The copper strip and protection pipe beyond 7.5 m length shall be measured and paid separately However, earthwork for the same is deemed to be included in this rate. (il) The desired value of earth resistance is less than 5 Q, on testing after completion if the desired earth resistance is not obtained: the earthing will be redone at no extra cost, otherwise it will not be measured and paid to the contractor. (iii) Form work of size 0 9m x 0.6m ‘or pouring charcoal & salt is deemed to be included in this rate (iv) During earth work if surface water found ai site. the cost for dewatering through pumpset is deemed to be included in this rate.
Supply, installation, testing and commissioning of servo controlled voltage stablizer outdoor type leonfirming to IS 9815:1994, copper wound naturally oil cooled , 3 phase 415 V 2.5% AC, 50 Hz of sapacity 125 KVA for unbalanced load with input voltege variation from 300V-480 V between phase to |phase with alarm/protection and by pass facility input voltage & current etc. and comprised of digital multifunction meter complete including platform as per |manufacturer’ s norms and first filling of transformer ‘oil complete all as specified and as directed with the undermentioned features as mentioned below:- Make: Volina/Brent Ford/AE FEATURES OF VOLTAGE STABILIZER: - (a) Micro controller tech based control module (b) Correction speed minimum 13 V per second and response time 20 mili second (c) High and low voltage cut off system (d) Overload and short circuit protection (e) High and low voltage cutoff (f) Earth leakage protection system (g) By pass switch shall have 3 position as below :- Position No 1: Stabilized supply to load Position No 2: No supply (both load and stabilizer are disconnected from mains. Position No 3: Stabilizer is by passed and isolated and load is directly feed from mains. Notes:- (i) The manufacturer shall state the no load and full load losses corresponding to minimum rated input voltages. The tolerances on these declared values shall be provided in Table 7 of IS 2026 (part-I): 1977. The no-load current shall not be more than 5% of the rated output current, Please ref BIS clause 9.4&9.5. (ii) The efficiency of servo voltage stabilizer shall be not less than 95% as per clause 9.6 of BIS. (iii) The following testing of servo voltage stabilizer should be carried out in manufacturer work shop in presence of Rep of Accepting Officer :- (a) Physical examination (b) Insulation resistance (c) High voltage test (d) Leakage current test (e) Provision for earthlings (f) Output voltage (g) No load current (h) Measurement of no load losses (j) Inducted voltage test
Supply, installation, commissioning and testing of double copper wound transformer step down, oil immersed, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage within limit, all as per IS 1180 (Part-I 2014 As per amendment No 4 . Mar 2021, Level I) of capacity 200 KVA complete. Make- Andrew Yule/Bharat Bijlee/Voltamp/ABB/ITE. The Transformer shall have following specification complete all as specified. (i) No Load Voltage ratio - 11000/433 Volt (ii) Tapping on HV % - + 7.5, + 5, + 2.5 (iii) 3 Phase and frequency - Phase and 50 Hz. (iv) Vector group - Dyn 11 (v) Connection - Delta star (vi) Type of cooling - ONAN (ix) Impedance - 4.5 % (x) Temp rise in Oil - 35 Deg C (xi) Type - Out door (xii) Temp rise in winding - 40 Deg CTerminal arrangement HV Side - Three Nos Weather proof LV side - Quad furcating cable Box with copper bus bar terminal suitable to connect PVC cable. One additional neutral bushing terminal for earthing purpose. Fittings:- (i) Externally hand operated off circuit Tap switch with position indicator and locking device (ii) Conservator with oil gauge, filling hole, with plug and hole with lug (iii) undercarriage with four plain roller - (iv) Oil filling hole cum air release plug - one no (v) Drain valve cum sampling valve - One No (vi) Filter valve with plug - One No (vii) Rating plate & Diagram plate - One (viii) Lifting lugs For transformer - Two No (ix) Lifting lugs Forlids - Two No (x) Earthing terminals-Two no (xi) Thermometer pocket- One (xii) Silica gel breather - One (xiii) Explosion vent - One (xiv) Inspection cover- One (xv) 6" Dial type thermometer with alarm & trip & max temp indicator- One
MONA GENERATOR SEVICES PVT. LTD.
M/s Torrent Inc
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .