Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC C 748 SECTOR C NEAR SHIV MANDIR SHAHPURA BHOPAL | BHOPAL | BHOPAL | MADHYA PRADESH | ₹14.8 L | L1 | Accepted-AOC Accepted due to being lowest rate |
| 2 | L2₹15.8 LRejected-Finance | ₹15.8 L | L2 | Rejected-Finance Rate quoted more than L1 |
| 3 | L3₹15.9 LRejected-Finance | ₹15.9 L | L3 | Rejected-Finance Rate quoted more than L1 |
| 4 | L4₹16.1 LRejected-Finance | ₹16.1 L | L4 | Rejected-Finance Rate quoted more than L1 |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Disqualified by committee |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Dec 2025, 5:30 pmClosed
Executive Engineer P.W.D. Maint. Dn. No.I Bhopal
Executive Engineer P.W.D. Maint. Dn. No.I Bhopal
AR SR works of sewer line chambers drain etc in Resi. buildings GST department work at all Section of PWD. City Sub Dn. No.3 Bhopal.
2025_PWDRB_466683_1
90/SAC/2025-26 dt.08.12.2025
Open Tender
Civil Works - Buildings
330 days
Bhopal
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
₹50,000
16 Mar 2026
8 Dec 2025
29 Dec 2025
8 Dec 2025
26 Dec 2025
8 Dec 2025
SCHEDULE OF ITEMS
General description of work : A.R, S.R. works of sewer line, Chambers, drain etc in residential buildings, GST Department works at all sections of P.W.D City Sub Dn N0. - 03, Bhopal.
Probable Amount of contract : Rs. 25.00 Lakh.
(Rs. In Figures) : Rupees Twenty five Lacs only.
Time Allowed : Eleven months i/c rainy season
S.No SOR Item Particulers of Item Unit Rate Remarks
1 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre.
1.2.1 Lime, moorum, building rubbish cum 53.43
1.2.2 Earth cum 66.78
1.2.3 Manure or sludge cum 58.07
1.2.4 Excavated rock cum 106.85
1.2.5 Sand, stone aggregate below 40mm nominal size cum 66.78
1.2.6 Stone aggregate 40mm nominal size and above cum 72.2
1.2.7 Stone soling cum 78.57
1.2.8 Bricks 1000 Nos. 124.66
1.2.9 S.W. Pipes
1.2.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and reinforced cement pipes
2 1.3 Add extra for every additional lead of 50 metre or part thereof.
1.3.1 Lime, moorum, building rubbish cum 11.63
1.3.2 Earth cum 14.54
1.3.3 Manure or sludge cum 12.64
1.3.4 Excavated rock cum 23.27
1.3.5 Sand, stone aggregate below 40mm nominal size cum 14.54
1.3.6 Stone aggregate 40mm nominal size and above cum 15.72
1.3.7 Stone soling cum 17.11
1.3.8 Bricks 1000 Nos. 27.14
1.3.9 S.W. Pipes
3 1.3.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and unreinforced cement pipes
4 2.1 Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil. 100 sqm 803
5 2.2 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 100 sqm 414
6 2.3 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 100 sqm 213
7 2.4 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material.
2.4.1 beyond 30 cm girth up to and including 60 cm girth each 350
2.4.2 beyond 60 cm girth up to and including 120 cm girth each 1150
2.4.3 beyond 120 cm girth up to and including 240 cm girth each 3500
2.4.4 above 240 cm girth each 6300
8 2.5 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil sqm 43
9 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil cum 147
10 2.7 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.
2.7.1 Ordinary rock cum 287
2.7.2 Hard rock (requiring blasting) cum 519
2.7.3 Hard rock (blasting prohibited) cum 828
11 2.8 Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means)
2.8.1 Ordinary rock cum 216
2.8.2 Hard rock (requiring blasting) cum 452
2.8.3 Hard rock (blasting prohibited) cum 593
12 2.9 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil
2.9.1 Pipes, cables etc., not exceeding 80 mm dia. metre 96
2.9.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 156
2.9.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. metre 244
13 2.1 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). metre 1.34
14 2.11 Extra for excavating trenches for pipes, cables, etc., in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) metre 3.45
15 2.12 Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m including including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :
2.12.1 Ordinary rock :
2.12.1.1 Pipes, cables etc. not exceeding 80 mm dia. metre 139
2.12.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. metre 344
2.12.1.3 Pipes, cables exceeding 300 mm dia but not exceeding 600mm dia metre 395
2.12.2 Hard rock (requiring blasting)
2.12.2.1 Pipes, cables etc. not exceeding 80 mm dia. metre 251
2.12.2.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 621
2.12.2.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia metre 715
2.12.3 Hard rock (blasting prohibited)
2.12.3.1 Pipes, cables etc. not exceeding 80 mm dia. metre 270
2.12.3.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 670
2.12.3.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia. metre 770
16 2.13 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceedin metre 1.02
17 2.14 g 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) metre 2.52
18 2.15 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 3m in depth but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.)
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.15.1 sqm 118
Depth not exceeding 1.5 m. 2.15.2 sqm 122
Depth exceeding 1.5 m but not exceeding 3 m. 2.15.3 sqm 130
19 2.16 Depth exceeding 3 m but not exceeding 4.5 m.
Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). 2.15.1 sqm 120
Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered) : 2.15.1 sqm 105
22 2.23 Extra for planking, strutting and packing materials for cavities (in close timbering) if required to be left permanently in position. (Face area of timber permanently left to be measured).
Extra rates for quantities of works, executed: 2.23.1 In or under water and/or liquid mud, including pumping out water as required. 0.2
metre depth 2.23.2 In or under foul position, including pumping out water as required. Note: - The extra percentage rate is applicable in respect of each item but limited to quantity executed in difficult conditions. The depth shall be reckoned correct to 0.1 metre. 0.05 metre or more shall be taken as 0.1 metre and less than 0.05 metre ignored. 0.25
23 2.24 metre depth cum 95
24 2.25 Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) 2.25.1 cum 30
All kinds of soil. 2.25.2 cum 53
25 2.26 Ordinary or hard rock. cum 672
26 2.27 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm.
Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 cum 393
With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) 2.27.2 cum 331
27 2.28 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete.
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then refiling the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc., disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5m. 2.25.1 each 42
2.28.1 Ordinary rock each 68
2.28.2 Hard rock (requiring blasting) each 138
2.28.3 Hard rock (blasting prohibited) each 151
28 2.29 2.28.4 Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) 174
Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.30.1 metre 36
Along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.2 metre 42
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.3 sqm 199
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.4
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep metre 50
holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.5 metre 201
30 2.31 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. cum 22
31 2.32 Deduct for disposed soil not levelled and neatly dressed. sqm 136
32 2.33 Preconstruction antitermite treatment to the building under construction by providing.Stage 1: Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. metre 205
33 2.34 Making bore holes for providing dowel bars at designed depth in rock foundation by drilling 40 mm dia bore hole in rock including necessary bending hooking, in position and grouting with cement slurry etc. complete as per drawing and specification. (Steel to be paid separately). cum 55
34 2.35 Excavation in soil using hydraulic excavator and including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- section, and transporting to the appropriate ground contour, location and levelling and dressing earth neatly with all lifts and lead upto 1000 metre. cum 130
35 2.36 Earth work in rough excavation by any means and banking\filling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne in embankments for roads, flood banks, marginal bank and guide bank of filling up ground depression within campus, lead upto 50m and all lift. All kinds of soil. cum 80
36 2.37 Banking\filling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne roller or wooden or steel rammers etc. and rolling every 3rd and top-must layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal bank and guide bank etc. lead upto 50m and lift upto 1.5m. All kinds of soil. cum 19
37 2.38 Deduct for not rolling with power roller of minimum 8 tonnes for banking\filling excavated earth in layers not exceeding cum 15
38 2.39 20cm in depth.
Deduct for not watering with the excavated earth for banking\filling Providing and laying of permanent piping technology anti-termite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30 cm interval in the tube,. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineer-in- charge with bond of 5 year warranty. sqm 113
2.39.1 Permanent piping system with Junction boxes sqm 53
40 2.41 Anti-termite chemical injected area sqm 897
41 2.42 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (All kinds of soil)
Providing , laying, spreading, and compacting, brick bats in uniform thickness 250 mm with hand packing, rolling, with vibratery roller 8-10 tonnes in stages to proper grade, watering and compacting to required density. 2.42 Ground and embankme nt filling Supplying and filling in Ground and embankment including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. cum 331
43 3.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. cum 5929
44 3.3 Cement mortar 1:1 (1 cement: 1 sand) cum 5127
45 3.4 Cement mortar 1:2 (1 cement: 2 sand). cum 4361
46 3.5 Cement mortar 1:3 (1 cement: 3 sand). cum 3948
47 3.6 Cement mortar 1:4 (1 cement: 4 sand) . cum 3595
48 3.7 Cement mortar 1:5 (1 cement: 5 sand). cum 5497
49 3.8 Cement mortar 1:6 (1 cement: 6 sand). cum 5516
50 3.9 Cement mortar 1:2 (1 cement: 2 stone dust). cum 9189
51 3.1 Cement mortar 1:2 (1 cement: 2 marble dust). cum 3637
52 3.11 White cement mortar 1:2 (1 white cement: 2 marble dust). cum 7416
53 3.12 Cement mortar 1:5 (1 cement: 5 marble dust). cum 5158
54 3.13 White cement mortar 1:3 (1 white cement: 3 marble dust). cum 4024
55 4.1 White cement mortar 1:5 (1 white cement: 5 marble dust).
Mortar in lime , surkhi (50% red and 50% light yellow) and marble dust 1:1.5:0.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :
4.1.1 With 20mm nominal size graded stone aggregate. cum 6338
4.1.1.1 M-25 – Grade concrete cum 4933
4.1.1.2 M-20 – Grade concrete cum 4471
4.1.1.3 M-15 – Grade concrete cum 3890
4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate )
4.1.2 With 40mm nominal size graded stone aggregate. cum 4403
4.1.2.1 M-15 - Grade concrete cum 3808
4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) cum 3474
4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate
4.1.3 With fly ash. 4.1.3.1 3459
1:2:3½:9 (1 ordinary Portland cement : 2 Fly ash : 3½ sand: 9 graded stone aggregate 40 mm nominal size) Cum 4.1.3.1 3150
1:2½:4:11 (1 ordinary Portland cement : 2½ fly ash : 4 sand : 11 graded stone aggregate 40 mm nominal size) Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing :
4.2.1 With 20mm nominal size graded stone aggregate. 4.1.3.1 6582
With 20mm nominal size graded stone aggregate 4.2.1.1 4.1.3.1 5177
4.2.1.2 M 20 – Grade concrete 4.1.3.1 4714
4.2.1.3 M 15 – Grade concrete 4.1.3.1 4134
4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate
4.2.2 With 40mm nominal size graded stone aggregate. cum 4647
With 40mm nominal size graded stone aggregate 4.2.2.1 cum 4052
M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Centering and shuttering including strutting, propping etc. and removal of form work for : Sqm 169
4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. sqm 267
4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. Sqm 356
Above plinth: Columns, pillars, posts and struts. Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . cum 4471
4.4.1 M-15 (With 20mm nominal size graded stone aggregate) cum 3890
60 4.6 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement morta1:3 (1 cement : 3 sand) on exposed surfaces complete.(With 20mm nominal size graded stone aggregate) Providing and fixing upto floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 sand) on exposed surfaces complete. cum 5095
4.6.1 M-25 (With 20mm nominal size graded stone aggregate) cum 5558
4.6.2 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . cum 5095
M-20 (With 20mm nominal size graded stone aggregate) 4.6.3 cum 4515
M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . cum Providing and fixing upto floor two level precast cement concrete solid block including hoisting and setting in position with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete :
M-10 (M 10) (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . cum 5339
Providing and Fixing upto floor two level pre cast concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete. 4.8.1 cum 5072
64 4.1 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. Sqm 200
65 4.11 Add extra for item no. 4.6, 4.7 and 4.8 above floor two level for every additional floor or part there of sqm 247
66 4.12 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size). 44
67 4.13 Extra for providing and mixing water proofing material as per IS standard in cement concrete work quantity as prescribed by the manufacturer. Sqm 124
68 4.14 Per bag of 50 kg of cement cum 0.01
69 4.15 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. Extra for concrete work in superstructure above floor two level for each floors or part thereof 297
70 4.16 Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. Note for item No. 4.15:- The quantity will be calculated by multiplying. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored. cum 109
71 4.17 cum per meter depth sqm 351
72 4.18 Extra for laying concrete in or under foul positions. 45
73 4.19 Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) each 485
74 4.2 Extra for addition of synthetic polyester triangular fiber of length 12 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/ Water retaining structures by using 125 gms of synthetic polyester triangular fibre for 50 kgs cement used as per directions of Engineer-in- Charge. cum 6583
75 4.21 per bag of 50 kg of cement cum 9843
76 4.22 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. cum 7469
77 4.23 Providing and fixing up to floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size)
78 5.23 Providing and fixing up to floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size)
Providing and fixing up to floor two level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete . 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) cum 5810
Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Note : (1) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacemen to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC. 4.23.1.1 cum 5720
M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.1.2
M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) cum 5930
79 4.24 All works above plinth and upto floor two level
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in- charge. Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) cum 5910
All works up to plinth level: 4.23.1.2
4.24.1.1 Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) cum 6315
Plum Cement concrete 1:2:4 with 75% graded metal of maximum size 40 mm and 25% plum of 150mm size.
Providing and laying cement concrete in Sunken floors of WC, Toilet, Wash Area, etc with 1:5:10 (1 cement : 5 coarse sand (zone-3) : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) cum 6153
excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 cum 5397
83 5.2 M-20 Grade Concrete
5.1.2 Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) cum 6231
84 5.3 M-15 Grade Concrete
Reinforced cement concrete with 20mm graded nominal size stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) cum 6541
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) cum 5542
Providing and laying upto floor two level reinforced cement concrete (with20 mm nominal size graded stone aggregate) in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with Concrete grade. Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) 6906
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in arches, archribs, domes, vaults, shells, folded plate above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in Concrete grade. Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) cum 6337
Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in chimneys, shafts, upto floor two level excluding the cost of centring, shuttering, finishing and reinforcement with Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) cum 5448
90 5.9 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in well-steining excluding the cost of centering, shuttering, finishing and reinforcement with
5.7.1 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in vertical and horizontal fins individually or forming box louvers, facias and eaves boards up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in M 20 –Grade Concrete sqm 190.6
Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.1
Foundations, footings, bases of columns, etc. for concrete upto plinth level 5.9.2 sqm 219
Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 sqm 330
Uptoplinthlevel. 5.9.2.2 sqm 40
Above plinth upto 3.6 m height from plinth level 5.9.2.3 sqm 439.6
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. 5.9.3 sqm 290
Suspended floors, roofs, landings, balconies and access platform. 5.9.4 sqm 356
Shelves(Cast in situ) 5.9.5 sqm 471.2
Lintels, beams, girders, bressumers and cantilevers 5.9.6 sqm 435.7
Columns, P i l l a r s , Piers, Abutments, Posts and Struts. 5.9.7 sqm 450
Stairs, (excluding landings) except spiral- Staircases. 5.9.8 sqm 1141.6
40307 Spiral staircases (including landing). sqm 451.3
41038 Arches, domes,vaults upto 6m span sqm 1481
41403 Extra for arches, domes, vaults exceeding 6 m span sqm 264
41768 Chimneys and shafts sqm 643.4
42133 Coffer/waffle slab of any size or shape as shown in the drawing. sqm 0.2
42499 Well steining sqm 191
42864 Vertical and horizontal fins individually or forming Box louvers band, facias and eaves boards. sqm 565
43229 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). sqm 529.6
43594 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. sqm 534.2
43960 Cornices and mouldings sqm 575.35
44325 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. sqm 521.2
91 5.1 Weather shade, Chajjas, corbels etc., including Edges.
Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of S.E. in case of B & R works and from Additional Project Director in case of PIU works) Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of S.E. in case of B&R works and from Additional Project Director in case of PIU works) sqm 212
92 5.11 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof (Plan area to be measured) cum 7830
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. sqm 790
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 sand) etc. complete excluding plastering of the jambs, sills and soffits. 5.12.1 sqm 689
50 mm thick 5.12.2 sqm 598
94 5.13 40 mm thick cum 6934
96 5.15 25 mm thick sqm 408
97 5.16 Encasing rolled steel sections, in beams and columns, with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) including centering and shuttering complete but excluding cost of reinforcement.
Encasing rolled steel section in grillages with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including centering and shuttering but excluding cost of expanded metal and hangers. Extra for providing and fixing expanded metal mesh of size 20x60mm and strands 3.25mm wide 1.6mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages excluding cost of hangers. kg 78
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.1 kg 75
Mild steel and Medium Tensile steel bars. 5.16.2 kg 81
Hard drawn steel wire 5.16.3 kg 81
Cold twisted bars (CTD) 5.16.4 kg 76
Hot rolled deformed bars 5.16.5 kg 80
98 5.17 Hard drawn steel wire fabric kg 0.2
99 5.18 5.16.6 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 D or more conforming to IS 1786 472
100 5.19 Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. Providing and fixing in position copper plate as per design for expansion joints. 45353
101 5.2 Kg Providing and fixing in position copper plate as per design for expansion joints. 13863
102 5.21 Providing and filling in position, blown bitumen in expansion joints. per cum 104.54
103 5.22 Providing and filling in position bitumen mix filler of Proportion 80 kg. Of hot bitumen, 1 kg. Of cement and 0.25 cubic metre of sand for expansion joints.
Providing and filling gap in expansion joint between RCC/ Stone/Ceramic tiles/Granite/ Marble by providing silicon sealant over backer rod of approved quality weather sealant as per drawing and direction of engineer in charge up to 25mm width & 12 mm depth. Per cm depth per cm width one m long. sqm 402
Providing and fixing in position bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound in expansion joints. 5.12.2 sqm 574
5. 22.1 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. sqm 674
104 5.23 12 mm thick
Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 RM 102
Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 RM 137
250mm wide. 5. 23.2 RM 483
Aluminium fluted strips 3.15mm thick. 5. 23.2.1 RM 646
Stainless steel Grade 304 plate-1.0 mm thick 5. 23.2.2 RM 555
108 5.27 Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete. Note- For Item No. 5.25:-The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering unde
r sub – soil water condition Extra for laying reinforced cement concrete in or under foul positions. cum 6100
Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-20 grade for reinforced cement concrete work using cement content as per approved mix design concretewithout impairing strength and durability as per direction ofEngineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 320 kg/cum) and no extra payment for extra cement used as per mix design. cum 6581
5.27.1 All works upto plinth level. cum 72
All works above plinth level and upto floor five level. 5.27.3 cum 110
Add extra for each floor for all works above floor five level. Extra for providing richer mixes of BMC design mix as per item no 5.27 upto plinth level and at all floor levels. (No extra payment for using extra cement as per requirement of mix design.) cum 140
5. 28.1 Providing M-25 grade concrete instead of M- 20 grade.(Note : minimum cement content is @ 330 kg/cum) cum 280
111 5.3 Providing M-30 grade concrete instead of M- 20 grade.(Note: : minimum cement content is @ 340 kg/cum)
5. 28.3 Extra for laying reinforced cement concrete in or under foul positions. cum 6332
Providing M-35 grade concrete instead of M- 20grade.(Note: minimum cement content is @ 350 kg/cum) Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in M-20 –Grade Concrete (with graded stone aggregate 10mm nominal size. including provision of steel hooks for lifting and form work, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement. cum 6814
Providing and laying in position ready mixed concrete (RMC) of M-20 grade for reinforced cement concrete work, using cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Note: Minimum cement content is @ 320 kg/cum. (No extra payment for using extra cement as per requirement of mix design.) 5.30.1 cum 72
112 5.31 5.30.2 cum All works above plinth level and upto floor V level.
Extra for each additional floor for all works above floor five level Extra for R.C.C. work above floor two level for each floors or part thereof. (except items 5.27 and 5.30) sqm 93
1% of respective item Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. sqm 100
Non pigmented wet curing compound 5.32.2 RM 366
Pigmented wet curing compound. Providing and fixing in position factory made precast RCC M-40 doors, windows and ventilator frames having excellent smooth finish, as per IS: 6523 with 6mm dia main reinforcement each polymer block having at least four holes for passing one or adjacent rebates to hold fast grill or steel bar, ventilator frame provided with grooves for louvers at an angel of 45 degree at spacing to block direct vision etc. complete, as per the direction of Engineer-in-charge. The cost of hold fast and cement concrete block of 1:3: 6 (1 Cement: 3 sand: 6 Graded stone aggregate 20mm nominal size) mix is also included in the item. RM 339
5. 33.1. Frame 125 mmx 60 mm (double rebate) RM 325
116 5.35 Frame 100mmx 60 mm (Single rebate)
Frame 85mmx 60 mm (Single rebate) Per cm depth per cm width one m long. sqm 441
Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 sand). Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water sqm 894
absorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 5. 35.1 sqm 1194
118 5.37 25 mm thick.
5. 35.3 50 mm thick. meter 96
Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. Providing and fixing sheet covering over expansion joints with iron screws as per design. Non- asbestos cement bonded particle board 6 mm thick as IS: 14276 meter 130
5.37.1 150mm wide meter 160
119 5.38 5.37.2 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 D or more conforming to IS 1786 168
120 5.39 200mm wide
5.37.3 250mm wide metre 4857
Providing & laying in position Prestressing steel strands (low relaxation) on hollow core bed by using mechanical pulling arrangement like Rabbit/ Bed master including all accessories for Stressing &destressing operations as per approved make conforming to IS1343 & grade FY-1860 etc, complete as per drawings and direction of Engineer -in- charge. Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In- Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer - inCharge. (Material shall confirm to ASTM 6063). metre 5946
5. 39.1 Floor Joint of 100 mm gap metre 7616
Floor Joint of 150 mm gap 5. 39.3 metre 4044
Floor Joint of 200 mm gap Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). metre 4552
5. 40.1 Wall Joint of 100 mm gap metre 5293
Wall Joint of 150 mm gap 5. 40.3 metre 4509
Wall Joint of 200 mm gap Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge.The joints shall be of extruded aluminum base members with self aligning and self centeringarragement support plates asper ASTM B221-02. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contam metre 5017
inants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 5.41.1 metre 5950
123 5.42 Roof Joint for 100 mm gap sqm 20
125 6.1 Roof Joint for 150 mm gap
5.41.3 Roof Joint for 200 mm gap cum 5818
Providing and fixing Scaffolding net of required width made of high density Polyethylen UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 5626
126 6.2 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not less than 40kg /cm2 and water absorption not more than 15% in foundation and plinth i/c curing etc. complete.
6.1.1 Roof Joint for 200 mm gap cum 6012
Cement mortar 1:4 (1 cement : 4 sand) Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 5821
Cement mortar 1:6 (1 cement : 6 sand) Roof Joint for 200 mm gap cum 5252
Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process ,crushing strength not less than 40kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level i/c curing etc. complete. 6.2.1 cum 5061
Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not les than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Roof Joint for 200 mm gap cum 5446
Cement Mortar 1:6 (1 cement:6 sand). Roof Joint for 200 mm gap cum 4347
Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete 6.4.1 cum 4155
6.6.1 Roof Joint for 200 mm gap cum 4541
6.6.2 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. cum 4350
6.5.2 Cement Mortar 1:6 (1 cement: 6 sand).
Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg/cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete Roof Joint for 200 mm gap cum 5384
Cement Mortar 1:6 (1 cement : 6 sand) Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : cum 5162
6.7.1 Having 100 kg / cm2 average compressive strength.
6.7.1.1 Roof Joint for 200 mm gap cum 5271
6.7.1.2 Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 5049
Cement mortar 1:6 (1 cement : 6 sand) 6.7.2
Having 75 kg / cm2 average compressive strength. Roof Joint for 200 mm gap cum 5158
6.7.2.1 Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 4936
6.7.3 Roof Joint for 200 mm gap cum 5287
Having 50 kg / cm2 average compressive strength. Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 5095
135 6.11 Brick work with calcium silicate bricks machine moulded conforming to IS:4139, having 100 kg/cm2 average compressive strength in super structure above plinth level upto floor II level in : cum 0.02
6.8.2 Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) sqm 697
Brick work with extruded burnt fly ash clay sewer bricks (conforming to IS: 4885) in archesin foundation and plinth including centering and shuttering complete in cement mortar 1:3 (1 cement: 3 sand). Roof Joint for 200 mm gap sqm 673
137 6.13 Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item .
Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) sqm 639
6.12.1 Roof Joint for 200 mm gap sqm 615
138 6.14 Cement mortar 1:3 (1 cement : 3 sand)
6.12.2 Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) sqm 546
Providing half brick masonry with well burnt chimney bricks in bull pattern trench kiln crushing strength not less than 25kg/cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level. 6.13.1 sqm 522
Providing half brick masonry with well burnt open bhatta bricks crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level 6.14.1
6.14.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 570
Half brick masonry with fly ash lime Gypsum bricks(FALG bricks) conforming to IS:12894, in super structure above plinth and upto floor two level. 6.15.1 sqm 551
Having 100 kg/cm2 average compressive strength. 6.15.1.1
Cement mortar 1 : 3 (1 cement : 3 sand) Cement mortar 1:4 (1 cement : 4 sand) sqm 524
Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.2
Having 75 kg/cm2 average compressive strength. Cement mortar 1:4 (1 cement : 4 sand) sqm 479
142 6.18 Having 50 kg/cm2 average compressive strength. sqm 456
145 6.21 Extra for half brick masonry in superstructure, above floor two level for every floor or part thereof respective item. cum 9691
146 6.22 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. metre 210
147 6.23 Honey-comb brick work 10 cm thick with well burnt chimney bricks manufactured by ghol process crushing strength not less than 40kg /sqcm and water absorption not more than 15% in cement mortar 1:4 (1 cement : 4 sand). Extra for forming cavity 5cm to 7.5cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. Ties 300mm long of 25x3mm section at not less than 3 ties per sqm as per approved design 297
148 6.24 Brick work in plain arches in superstructure including centering and shuttering complete with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 cement : 3 sand). cum 109
149 6.25 Brick work in gauged arches in superstructure in cement mortar 1:3 (1 cement : 3 sand) including centering and shuttering complete, with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% cum 5052
150 6.26 Providing half brick masonry with kiln burnt clay bricks of 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 Cement : 3 sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10 cm wide bitumen felt type 3 grade 1.
Extra for laying brick work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of brick work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. cum per metre depth cum 5500
151 6.27 Extra for laying brick work in or under foul position. cum 0.01
152 6.28 Providing and laying cellular concrete blocks masonry having density cum 5700
153 6.29 ranging from 800kg/m3 in super structure above plinth level up to floor two level in cement mortar 1:4 (1 cement: 4 sand) The nominal dimensions of the concrete blocks shall be as follows in additional block shall be of half lengths of 200, 250 or 300 mm to correspond to the full lengths. The size of the blocks specified other than those specified may also be used. cum 5800
Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM international standard including raking out joints. Vertical bands shall be placed along jams (vertical member of chowkhats) and extend upto lintel levels to arrest cracking at corner openings. RCC bands shall be measured with AAC block masonry. Rates include all materials including steel bars, wastages, scaffolding and all labour etc. complete.
155 6.31 AAC Masonry in polymer modified mortar cum 4237
156 6.32 Extra for AAC masonry work in superstructure above floor two level for each additional floor or part thereof
Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced roof slabs, lintels and chhajjas as per IS: 6073 -2006 grade D specifications (dry density, without steel, 550 kg/m3 to 650 kg/m3 and minimum compressive strength 3.5 N/mm2) reinforcement steel provided inside AAC slab, lintel and chhajja shall be ascertained on the basis of manufacturer’s certificate and also by random destructive testing done by engineer-in-charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Deflection & ultimate load test for AAC reinforced roof slab and lintel shall be as per annex. B of IS: 6073 -2006 and criteria for conformity and sampling shall be as per clause-13 of IS: 6073 -2006. Precast autoclaved aerated concrete (AAC) reinforced wall panels:- Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced wall panels as per IS:6072 -1972 grade D (dry density, without steel, 550 kg/m3 to 650 kg/m3 and inside AAC panels.Quantity of reinforcement steel in AAC panels shall be cum 4689
Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced roof slabs, lintels and chhajjas as per IS: 6073 -2006 grade D specifications (dry density, without steel, 550 kg/m3 to 650 kg/m3 and minimum compressive strength 3.5 N/mm2) reinforcement steel provided inside AAC slab, lintel and chhajja shall be ascertained on the basis of manufacturer’s certificate and also by random destructive testing done by engineer-in-charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Deflection & ultimate load test for AAC reinforced roof slab and lintel shall be as per annex. B of IS: 6073 -2006 and criteria for conformity and sampling shall be as per clause-13 of IS: 6073 -2006. ascertained on the basis of certificate of the manufacturer and also by random destructive testing by engineer-in- charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Cost of reinforcement inside AAC panels shall be paid separately. cum 5236
157 6.33 Add extra for AAC wall panels, roof slabs, lintels and chhajjas above floor two level for each additional floor as per item no 6.29 and 6.30.
Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry Jali work, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM 1660-09,applied in uniform thickness of 2 to 3 mm in horizontal and verticals joints using special trowel, polymer modified mortar having minimum compressive strength and minimum splitting tensile strength of not less than 5MPa and 0.34 MPa respectively as per ASTM international standard including raking out joints. The surface of masonry units (AAC- Block) should be slightly moist prior to Precast autoclaved aerated concrete (AAC) reinforced wall panels:- Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced wall panels as per IS:6072 -1972 grade D (dry density, without steel, 550 kg/m3 to 650 kg/m3 and inside AAC panels.Quantity of reinforcement steel in AAC panels shall be cum 4038
Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) ascertained on the basis of certificate of the manufacturer and also by random destructive testing by engineer-in- charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Cost of reinforcement inside AAC panels shall be paid separately. cum 4563
159 6.35 From ground level upto plinth level sqm 70
160 6.36 Above plinth level upto floor II level sqm 1838
161 6.37 Brick work with modular bricks of class designation 7.5 in exposedbrick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level up to plinth level in cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor two level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 Extra for Gypsum panel Partitions in superstructure above floor two level for every four floors or part thereof. cum 5115
Providing and laying Red Brick work of size 200X100x50 mm on exposed wall in cement morter 1:3 including racking and jointing rubbing and filler polishing 2 coat as per direction by Engineer in Charge. Brick work with fly ash bricks up to plinth Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, cum 4904
6.37.1 Having100 kg / cm2 average compressive strength.
6.37.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5007
6.37.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4797
6.37.2 Having75 kg / cm2 average compressive strength.
6.37.2.1 Cement mortar 1:4 (1 cement : 4sand) cum 4900
6.37.2.2 Cement mortar 1:6 (1 cement : 6sand) cum 4797.00 cum 4689
Having50 kg / cm2 averagecompressive strength. Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 4147
Cement mortar 1:4 (1 cement : 4sand) 6.37.3.2 cum 4351
164 7.3 Cement mortar 1:6 (1 cement : 6sand) cum 0.025
165 7.4 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level with :
7.1.1 Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. cum 213
7.2.1 Cement mortar 1:6 (1cement: 6 sand). cum 894
166 7.5 Extra for random rubble masonry with hard stone in superstructure above floor two level for every floors or part thereof cum 354
167 7.6 Extra for random rubble masonry with hard stone in :
7.4.1 Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 4603
Square or rectangular pillars Extra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete) Note:- Applicable to item No. 13.1 to item No. 13.10 cum 4342
Circular pillars. Extra for random rubble masonry with hard stone c cum 4803
urved on plan for a mean radius not exceeding 6 m. Coursed rubble masonry(1st or 2nd sort)with hard stone in foundation and plinth. cum 4541
Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor two level. Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. cum 235
7.7.1 Cement mortar 1:6 (1cement: 6 sand). cum 1003
Masonry work (first sort) in cement mortar 1:6 (1 cement : 6 sand) 7.7.2 cum 384
171 7.1 Masonry work (second sort) , in cement mortar 1:6 (1 cement : 6 sand)
Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above floor two level for every floors or part thereof Extra for coursed rubble masonry with hard stone (first or second sort) in :
7.9.3 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 12998
Stone work in plain ashlar masonry in super structure upto floor two level in cement mortar 1:6 (1 cement : 6 sand) including pointing with cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the sand stone shade : 7.10.1
One face dressed. 7.10.1.1 cum 18003
Red sand stone Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 18080
White sand stone Extra for coursed rubble masonry with hard stone (first or second sort) in :
Both face dressed. Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 17207
Red sand stone. 7.10.1.1 cum 22264
7.10.2.2 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 22341
173 7.12 Stone work plain ashlar masonry in arches in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade.
7.11.2 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 27912
Stone work plain ashlar masonry in domes, in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.12.1 cum 39770
174 7.13 One face dressed
7.12.2.2 White sand stone. cum 1654100
Stone work ashlar masonry punched (ordinary) in superstructure above plinth level and upto floor two level in cement mortar 1:6 (1 white cement: 6 sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.13.1 cum 16618
175 7.14 Red sand stone one face punched. cum 123
Red sand stone both face punched Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. cum 1771
178 7.17 White sand stone one face punched. sqm 503
White sand stone double face punched 7.9.2 cum 20629
Extra for stone work, plain ashlar or ashlar punched above floor two level for every floor or part thereof. Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 19706
180 7.19 Extra for plain ashlar or ashlar punched in :
7.15.1 Extra for stone work; plain ashlar or ashlar punched in curved on plan with a mean radius not exceeding 6 m. cum 2310
Extra for additional cost of centering for arches exceeding 6m span including all strutting, bolting, wedging etc. And removal (area of soffit to be measured). Stone work sunk or moulded or sunk and moulded upto floor Two level in cement mortar 1:6(1cement : 6 sand) including pointing with white cement mortar 1:2 (1 white : 2 marble dust) with an admixture of pigment matching the stone shade : cum 6545
182 7.21 Extra for stone work sunk or moulded or sunk and moulded or carved in
7.19.1 Triangular or Square or rectangular pillars
7.19.2 Circular or polygonal pillars sqm 1321
Extra for stone work sunk or moulded in cornices. per metre per cm girth sqm 1299
Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 meter height backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of clamps which shall be paid for separately): Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. sqm 1276
7.21.1 Red sand stone - exposed face fine dressed with rough backing. sqm 1257
7.21.1.1 70 mm thick. sqm 1230
7.21.1.2 60 mm thick.
7.21.1.3 Circular or polygonal pillars sqm 1808
7.21.1.4 per metre per cm girth sqm 1785
40 mm thick. Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. sqm 1762
7.21.1.5 Red sand stone - exposed face fine dressed with rough backing. sqm 1739
30 mm thick. 70 mm thick. sqm 1717
7.21.2 Red sand stone- Exposed face machine cut and table rubbed with rough backing.
7.21.2.1 Circular or polygonal pillars sqm 1327
7.21.2.2 per metre per cm girth sqm 1303
7.21.2.3 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. sqm 1280
7.21.2.4 Red sand stone - exposed face fine dressed with rough backing. sqm 1256
7.21.2.5 70 mm thick. sqm 1233
7.21.3 White sand stone - exposed face fine dressed with rough backing.
7.21.3.1 Circular or polygonal pillars sqm 1813
7.21.3.2 per metre per cm girth sqm 1790
7.21.3.3 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. sqm 1766
7.21.3.4 Red sand stone - exposed face fine dressed with rough backing. sqm 1743
7.21.3.5 70 mm thick. sqm 1719
184 7.23 White sand stone-Exposed face machine cut and table rubbed with rough backing. kg 631
Extra for stone work (veneer work) curved on plan with a mean radius not exceeding 6 m. Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement :2 sand) including making the necessary chases in stone and holes in walls wherever required. sqm 1196
188 7.27 Providing and fixing stone dowels of size 10x5x2.5cm cut to double wedge shape as per design in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases.
Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1:4 (1cement :4 sand) including pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the stone shade: 7.9.2 sqm 744
7.26.1 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. sqm 744
189 7.28 Red sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. sqm 891
191 7.3 White sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength.
Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the 7.9.2 cum 13187
stone shade: Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. cum 13249
30mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement: 4 sand) including finishing complete. Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. sqm 5797
193 7.32 Providing and fixing red sand stone brackets 55x22.5x45cm sunk and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6mm 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design. Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 296
196 7.35 Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1cement :3 sand) including pointing in white cement mortar 1:2 (1white cement: 2stone dust) with an admixture of pigment , matching the stone shade, jali slab without any chamfers etc.
Extra for laying stone work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of stone work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. cum/mtr depth sqm 1469
Extra for laying stone work in or under foul position. Wall lining butch work upto 10m height with red sqm 900
/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width 75mm thick strips i/c 12mm thick bed of cement mortar 1:3 (1 Cement : 3 sand) i/c ruled pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in- charge. Stone work ( machine cut edges) for wall lining upto 10 m height etc. (Veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 Cement : 3 sand) and jointed with Cement mortar 1:2 (1 cement : 2 marble dust) including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid for separately) sqm 1122
25mm thick Kota stone slabs exposed face dressed and rubbed. 7.35.2 sqm 1524
25mm thick Dholpur stone slabs exposed face dressed and rubbed. 7.35.3 sqm 1119
198 7.37 20 to 25mm thick kota stone slabs exposed slab not dressed and rubbed. sqm 67
20 to 25mm thick Dholpur stone/shivpuri stone not dressed and rubbed. 7.10.1.1 sqm 1639
Stone tile work with 8mm thick mirror polished and machine cut edge for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sand), including pointing in white cement with an admixture of pigment to match the stone shade. Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. sqm 1706
201 7.4 Granite stone of any colour and shade each 208
203 8.2 Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble sqm 2674
204 8.3 Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. sqm 3200
Providing and fixing dry stone cladding upto 10 metre height with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and/ or with the help of cramps, pins etc. And sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins. shall be paid for separately.)
207 8.6 Providing and fixing structural steel frame (for dry stone cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/rectangular tube in the required pattern as per architectural drawing including including drilling necessary steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution).The frame work shall be fixed in true horizontal and vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel clamps shall be paid for separately and nothing extra shall be paid.) sqm 1706
208 8.7 Providing and fixing adjustable stainless steel clamps of approved quality and of required shape and size adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding fixed on frame
Providing and supplying aluminium extruded tubular and other aluminium sections frame work as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coated of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. sqm 3800
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.8.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. sqm 3556
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick having density 48 kg/m3, conforming to IS: 8183 and BS: 3958 Part 5.The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non- woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm/sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. sqm 3312
209 8.8 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in Sqm 5983
210 8.9 the vision panels etc., included in cost of relevent Item). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. sqm 4004
211 8.1 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (ACP) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places. sqm 3883
4 mm thick alumminium composite pannel material consisting of 3 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.5mm thick) 8.7.2 cum 90618
4 mm thick alumminium composite pannel material consisting of 3.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 8.7.3 cum 71309
3 mm thick alumminium composite pannel material consisting of 2.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) Design, supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete.For the purpose of payment actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. cum 72744
Providing and fixing aluminium magnesium alloy (FACADE) wall cladding system consisting of panels 200mm wide x 17mm deep x 0.5mm thick of maximum length of 6.0 mtr. coil coated on a continuous paint line double baked and roll formed from centre to centre at a distance of maximum 1.20 mtr. The stringer shall be fixed to a suitable rigid structure. All panels shall be achromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and the other side (inner side) with a primer coat on a continuous paint line, and fixed as per the direction of the Engineer-in-Charge. Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line. Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 meter 389
Second class teak wood 9.1.2 meter 457
213 9.2 Sal wood cum 92195
Kiln Head wood seasoned and chemically treated hard wood (Haldu, Kail, Bija wood.) 8.7.3 cum 76229
9.1.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 77538
9.1.4.1 Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line. Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places. cum 64833
215 9.4 Frame of size 100mmX60mm single or double rebate
Frame of size 120mmX60mm double rebate. 8.7.3 cum 7131
Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001(Part-B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixing in position with hold fast lugs or with dash fasteners of required dia and length ( hold fast lugs or dash fastener shall be paid for separately). Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) cum 7275
9.3.1 Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line. Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places. cum 6030
Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 8.7.2
9.3.3 Extra for additional labour wood work in circular shape, such as in frames of fan light : sqm 2776
9.4.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood.
Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Extra for additional labour wood work in circular shape, such as in frames of fan light : sqm 2205
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling/glazing which will be paid for separately, all complete as per direction of Engineer-in-charge. 9.5.1
9.5.1.1 Extra for additional labour wood work in circular shape, such as in frames of fan light : sqm 2060
35 mm thick shutters 9.4.2 sqm 1816
9.5.1.2 30 mm thick shutters
217 9.6 Kiln seasoned selected planks of sheesham wood.
Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood shutters 9.5.4.1 sqm 971
35 mm thick 9.5.4.2
30 mm thick Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: sqm 1439
Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.6.3
15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. 9.6.4 sqm 1861
Ply wood 5 ply, 9 mm thick : 9.6.4.1 sqm 1650
Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. 9.6.4.2
Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type 9.6.5 sqm 791
Ply wood 7 ply, 9 mm thick : 9.6.5.1 sqm 1087
Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. 9.6.5.2 sqm 1333
Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type 9.6.6 sqm 1390
Particle Board 12 mm thick 9.6.6.1 sqm 1298
Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. 9.6.6.2
Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. 9.6.6.3 sqm 973
Pre-laminated particle board with decorat ive lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. sqm 1046
9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. sqm 1532
9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick sqm 580
9.6.7 Float glass panes sqm 754
218 9.7 4 mm thick glass pane (weight not less than 10 kg/sqm)
9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) sqm 2717
9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading sqm 2868
9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum sqm 2775
4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick 8.7.2
laminated sheet with density not less than 1400 kg/cum 9.5.2.1 sqm 3408
Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer-in- charge and panelling with panels of: 9.5.3 sqm 3033
12mm thick plain grade - 1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT - I IS : 3087 marked bonded with BWP type synthetic resin adhesive as per IS : 848 : 9.5.2.1 sqm 2758
12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre- lamination conforming to IS : 12823 Grade 1, Type - II marked: 9.5.1
12 mm thick one side pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and prelamination conforming to IS : 12823 Grade -1, Type II marked: 9.5.3 sqm 2331
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.8.1
9.8.1.2 Extra for additional labour wood work in circular shape, such as in frames of fan light : sqm 1589
9.8.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood sqm 400
222 9.11 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B) , using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked fixing with M.S. pressed butt hinges bright finished of required size with necessary screws as per directions of Engineer-in- charge. 30 mm thick shutters. sqm 236
223 9.12 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) sqm 15
225 9.14 5 mm thick instead of 4 mm thick.
9.10.2 10 to 12 mm float glass sqm 170
9.10.3 5.5 mm safety glass sqm 53
10-12mm safety glass Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Deduct for providing pin headed glass panes instead of ordinary float glass panes 4mm thick in doors, windows and clerestory windows, shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). Extra for S.S, hinges providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). sqm 2736
Deduct for not providing hinges in doors, windows or clerestory window shutters with : 9.14.1 sqm 2753
Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. 9.14.2
ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. Providing and fixing 25 mm thick Second class teak wood shutters using 4mm float glass for cup board etc. : sqm 2815
9.15.1 Panelled or panelled and glazed shutters : sqm 2759
Using ISI marked anodised aluminium butt hinges with necessary screws. Per cm depth per cm width one m long. sqm 555
9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 654
Glazed shutters : Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 1270
229 9.18 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws.
9.15.2. 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 2823
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) : 9.16.1 sqm 2648
9.16.2 18 mm thick sqm 2465
230 9.19 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative and other side balancing lamination Grade I,Type II exterior grade IS :12823 marked in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately).
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.16.1 sqm 1696
9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 1623
232 9.21 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 401
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. sqm 157
9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 244
236 9.25 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws.
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only. Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 9.22.1 sqm 3174
Rectangular or square. 9.22.2 sqm 2599
Circular. Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door sqm 2452
shutters to be measured). Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wire gauze shutters using galvanised M.S. wire gauze of average width of aperture 1.4mm in both direction with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws: 9.22.1 sqm 3291
35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door sqm 2569
9.25.1.1 Second class teak wood.
Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.22.2 sqm 2306
9.25.1.3 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door sqm 2179
Kiln seasoned selected class of sheesham wood. 9.25.2
35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.22.1 sqm 2914
30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. Extra for additional labour wood work in circular shape, such as in frames of fan light : sqm 2427
9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. each 16
9.25.4.3 Kiln seasoned selected class of sheesham wood. each 21
Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, and as per TADS 15 :2001 (Part B) using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568 for doors, windows and clerestory windows including ISI marked M.S. pressed fixing with butt hinges bright finished of required size with necessary screws as per directions of Engineer-in-charge: 9.26.1 each 25
9.26.2 Providing 50x50x50mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 sand) and making good the walls etc. each 28
240 9.29 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete.
9.28.1 Red sand stone - exposed face fine dressed with rough backing. sqm 5407
25 mm long Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water sqm 3469
9.28.2 32 mm long sqm 2802
9.28.3 Per cm depth per cm width one m long. sqm 1768
241 9.3 40 mm long
50 mm long Per cm depth per cm width one m long. sqm 1174
9.28.5 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 1410
60 mm long 5.12.2 sqm 1525
242 9.31 Providing and fixing 2nd class teak wood plain lining tongued and grooved including wooden plugs complete with necessary screws and priming coat on unexposed surface. cum 96415
20 mm thick Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 1626
246 9.35 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre- laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on
unexposed surface, with necessary fixing arrangement and screws etc. complete : 9.30.1
Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Providing and fixing plywood 4 mm thick one side decorative veneer conforming to IS: 1328 (type-1) for plain lining / cladding with necessary screws, priming coat on unexposed surface with: Decorative veneer facings of approved manufacture. metre 147
Providing and fixing 4mm thick coir veneer board, ISI marked IS:14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw)
Providing and fixing skirting of Pre- laminated with(one side decorative and other side balancing lamination) flat pressed, 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : 9.30.3 metre 85
247 9.36 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : sqm 1773
249 9.38 2nd class teak wood metre 466
50x12 mm 9.35.1.2 metre 34
50x20 mm Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50x12 mm beading complete with : Second class teak wood. metre 289
Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked,, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842, including top cover of 6 mm coir veneer board, nickle plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. metre 377
Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18mm thick 150mm wide. 9.39.1 metre 382
253 9.42 Non decorative veneer on both sides.
9.39.2 Particle board with decorative veneering on both sides. metre 127
Providing and fixing teak wood lipping of size 25x3 mm in pelmet. Providing and fixing of 1.25 mm thick chromium plated brass plate, with two chromium plated curtain rods brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: metre 141
12 mm dia. 9.41.2 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 D or more conforming to IS 1786 119
20 mm dia. 9.41.3 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 D or more conforming to IS 1786 128
256 9.45 Providing and fixing nickel plated curtain rods M.S. pipe with nickel plated brackets : sqm 1224
20 mm dia (heavy type) 9.42.2 sqm 1000
25 mm dia (heavy type) Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. sqm 681
259 9.48 Fixed to steel windows by welding. each 95
Fixed to openings /wooden frames with rawl plugs screws etc. Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete. cum 72600
Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. cum 72550
With 2nd class teak wood beading 62x19 mm. 9.46.2 each 30
With 12 mm mild steel U beading. Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. each 23
Providing 40x5 mm flat (iron hold fast 40 cm long) (0.628 kg) including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) Providing wooden beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : each 18
9.49.1 Sal wood. each 10
Haldu, Kail, Bija wood. Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : each 53
Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete : Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. each 23
9.51.1 Providing wooden beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : each 17
125x90x4.00 mm Sal wood. each 10
50x40x2.50 mm Prov each 46
iding and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 9.52.1 each 39
Providing and fixing ISI marked oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete : 9.53.1 each 163
Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : 9.54.1 metre 133
150 mm 9.54.2 metre 138
125 mm 9.54.3 metre 141
Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 9.55.1 each 170
269 9.58 Providing M.S. Piano hinges ISI marked IS: 3818 finished with nickel plating and fixing with necessary screws etc., complete.
9.56.1 Overall width 35 mm. each 68
9.56.2 Overall width 50 mm. each 60
9.56.3 Overall width 65 mm. each 42
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 9.57.1 each 35
250x16 mm Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : each 72
Providing and fixing ISI marked 85x42mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete 9.52.4 each 23
Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 9.60.1 each 20
300x20x6 mm 9.60.2 each 17
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.61.1 each 40
75 mm Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : each 28
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. Overall width 35 mm. each 148
9.63.1 Overall width 50 mm. each 93
300 mm weighing not less than 200 gms. Overall width 65 mm. each 71
278 9.67 250 mm weighing not less than 150 gms. each 86
200 mm weighing not less than 120 gms. Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : each 211
Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors. (Weighing not less than 450 gms.) 250x10 mm each 173
280 9.69 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete:
Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.58.4 each 48
282 9.71 Providing and fixing ISI marked 85x42mm stainless steel pull bolt lock with necessary screws bolts, nut and washers etc. complete.
Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 9.61.1 each 79
9.68.2 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : each 49
283 9.72 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : each 272
Providing and fixing stainless steel hasp and staple (safety type) conforming to IS specification with necessary screws etc. complete : 9.70.1 each 59
Providing and fixing stainless steel casement stays (straight peg type) conforming to IS specification with necessary screws etc. complete. Sal wood. each 25
Providing and fixing stainless steel safety chain with necessary fixtures for doors. Conforming to IS specification (Weighing not less than 450 gms.) Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : each 60
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.74.1 each 148
75x50x2.50 mm Providing and fixing 50 mm Stainless steel cup board or wardrobe knob with necessary screws (best make of approved quality) each 145
Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete. Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : each 74
9.77.1 125x85x5.5 mm (heavy type) each 32
125x70x4 mm (ordinary type) 9.77.3 each 385
100x85x5.5 mm (heavy type) 9.77.4 each 345
100x70x4 mm (ordinary type) 9.77.5 each 304
75x65x4 mm (heavy type) 9.77.6 each 239
290 9.79 75x40x2.5 mm (ordinary type)
9.77.7 50x40x2.5 mm (ordinary type) each 400
Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : Overall width 35 mm. each 329
9.78.1 Overall width 50 mm. each 261
150x125x27x5 mm Overall width 65 mm. each 221
292 9.81 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
Providing and fixing bright finished brass door latch with necessary screws etc. complete. 9.80.1 each 374
297 9.86 Providing and fixing bright finished brass handles with necessary screws etc. complete. each 678
Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete. 9.82.1 each 150
299 9.88 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). each 51
300 9.89 Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). each 91
301 9.9 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). each 72
302 9.91 Providing and fixing bright finished brass night latch including necessary screws etc. complete (best make of approved quality).
Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) : 9.87.1 each 184
Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best make of approved quality) 9.60.1 each 94
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 9.60.2 each 80
304 9.93 Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. each 92
305 9.94 Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : each 780
307 9.96 300 mm weighing not less than 330 gms each 777
309 9.98 250 mm weighing not less than 280 gms each 766
200 mm weighing not less than 240 gms Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete: each 144
9.92.3 Providing and fixing Cromium plated brass hanging type floor door stopper with necessary screws, etc. complete. each 167
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. each 196
311 9.1 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). each 68
312 9.101 Providing and fixing chromium plated brass 100 mm mortice latch with one d
ead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 9.79.5 each 268
Providing and fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). 9.80.1 each 245
313 9.102 Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of :
9.99.1 Size 40 mm each 260
9.99.2 Size 50 mm each 198
9.99.3 Size 65 mm each 164
9.99.4 Overall width 50 mm. each 113
Size 75 mm Overall width 65 mm. each 91
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. 9.57.1 each 73
314 9.103 Providing and fixing chromium plated brass sliding door bolts ISI marked with nuts and screws etc complete.
Providing and fixing chromium plated brass tower bolts ISI marked with nuts and screws etc complete. 9.102.1 each 243
Providing and fixing chromium plated brass door latch ISI marked with necessary screws etc complete. 9.87.2 each 178
Providing and fixing chromium plated brass night latch ISI marked with necessary screws etc complete. Providing and fixing chromium plated brass handles with necessary screws etc. complete: each 108
9.105.3 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. each 93
Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete : 9.107.1 each 90
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Note:- Aluminum hinges shall not be used in wooden shutters. 9.108.1 each 75
100x63x4 mm Size 40 mm each 123
9.108.6 Overall width 35 mm. each 102
75x63x4 mm Overall width 50 mm. each 82
9.108.7 Overall width 65 mm. each 69
324 9.113 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.58.4 each 46
328 9.117 Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. complete. kg 441
329 9.118 Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.113.1 each 44
330 9.119 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.114.1 Single rubber stopper each 62
9.114.2 Twin rubber stopper each 82
331 9.12 Providing and fixing aluminium casement window stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. Providing and fixing aluminum U beading of required size to Pre-laminated /flush door shutter including fixing etc. complete as per direction of Engineer-in-charge. each 87
Providing and fixing PTMT handles with necessary screws etc. complete. 9.118.1 each 106
332 9.121 125x34x24 mm weighing not less than 23 gms. each 37
334 9.123 150x34x24 mm weighing not less than 26 gms.
Providing and fixing PTMT Butt hinges with necessary screws etc. complete. 9.119.1
75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms. 9.22.1 sqm 3583
9.119.2 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) sqm 3008
100x75x10 mm fitted with 5.5 mm dia MS Bright Bar Rod weighing not less than 53 gms. 9.25.2.3 sqm 2862
Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
152x42x18 mm weighing not less than 60 gms. Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) sqm 3125
202x42x18 mm weighing not less than 78 gms. Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms.
Providing and fixing PTMT hanging type floor door stoper with necessary screws etc complete. 9.22.1 sqm 3206
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) sqm 2715
35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.1.1
9.123.1.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) sqm 2832
9.123.2.3 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. sqm 1370
337 9.126 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. metre 182
9.123.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. each 28
342 9.131 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
9.124.1 9.124.2 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 209
Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50mm (base and height). Providing and fixing 2nd class teak wood lipping/ moulded beading or Taj beading of size 18x5mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer- in-charge. Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 256
Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete (Best make of approved quality). Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 302
344 9.133 Triple strip vertical type.
Double strip (horizontal type). Providing and fixing magic eye in door shutters including fixing. Complete (Best make of approved quality). sqm 1591
Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 sqm 1660
345 9.134 300mm long
each set 9.131.2 sqm 851
450mm long 9.131.3 sqm 691
346 9.135 500mm long sqm 1688
347 9.136 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by P/F stainless steel rollers to run inside C or
E aluminium channel section (The payment of C or E channel shall be made separately) Providing and fixing 12mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and sqm 1433
clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. 9.133.1 sqm 1322
348 9.137 Marine plywood conforming to IS: 710 sqm 1412
Fire retardant plywood conforming to IS: 5509. Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. sqm 919
9.134.1 1.5 mm thick. sqm 1161
9.134.2 Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water sqm 1230
350 9.139 1.0 mm thick. sqm 1726
351 9.14 Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge
Providing and fixing cup board shutters with 25mm thick veneered particle board IS : 3097 marked exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in- Charge. Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 1493
352 9.141 With decorative veneering on one side and commercial veneering on other side.
With non decorative veneering on both sides. Providing and fixing factory made shutters of 25 mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beading and hinges will be paid for separately). sqm 1212
Providing and fixing in wall lining MDF board medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 9.138.1 sqm 905
12 mm thick. 9.138.2 sqm 1491
18 mm thick. 9.138.3 sqm 1212
Providing and fixing 25mm thick pre- laminated medium density fibre board exterior grade(Grade-I) IS:14587:1998 marked one side decorative to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickeled plated bright finishing M.S. piano hinges IS:3818 marked with necessary screwed complete Providing and fixing skirting with Pre- laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand complete. sqm 1450
353 9.142 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a
flush finish with recommended jointing compound, jointing tape, angle beads at corner (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 9.141.1 sqm 834
75mm overall thickness partition with 12.5 mm thick double skin fire rated glass reinforced gypsum (GRG) plaster board conforming to IS: 2095: part 3 1996 Board with BIS certification marks. 9.141.2 sqm 550
75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS:2095: part I 1996 Board with BIS certification marks. 9.141.3 sqm 675
66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./sq.cm. 9.141.4 sqm 1072
66mm overall thickness partition using 8mm thick double skin non- asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre cement screw. 9.141.5 sqm 760
354 9.143 68mm over all thickness partition using 9mm thick Heavy Duty Fibre Cement Board double skin non asbestos, reinforced with cellulose fibre,manufactured through autoclaving proces(High presssure steam cured)Type A, Category 4 onforming to IS 14862:2000. (for wet areas) kg 101
70 mm overall thickness Partition using 10mm thick double skin non-asbestost multipurpose termite, fire & moisure resistance (acoustic 30db) cement bonded particle board as per IS: 14276 with suitable cement bonded board screw.
356 9.145 Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the 'W' profile (0.55mm thick ) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55 mm, placed @ 610mm C/C with fully threaded self- tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200mm C/C., all complete as per the drawing and directions of engineer-in-charge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish.
9.142.1 10 mm thick tapered edge calcium silicate board made with calcareous and siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure, with compressive strength 225 kg/sq.cm, Bending strength 100 kg/sq.cm. sqm 811
9.142.2 12 mm thick Gypsum board conforming to IS: 2095 Part-I. sqm 943
8 mm thick non-asbestost multipurpose termite, fire & moisure resistance cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 1055
358 9.147 8mm Both side Factory Prelamianted cement bonded particle board as per IS: 15786. sqm 7566
360 9.149 9mm thick non asbestos,heavy duty fibre cement board reinforced with cellulose fibre manufactured through autoclaving process(High pressure steam cured) Type A,Category 4, conforming to IS 14862.
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically and horizontally ) including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer- in-charge. sqm 1427
Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 sqm 1303
361 9.15 Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). sqm 1040
9.145.1 Board 12 mm thick sqm 1210
9.145.2 Board 18 mm thick sqm 1320
362 9.151 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). sqm 3716
365 9.154 Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric (colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel having metal framing, of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending outward. Then panels shall positioned and pressed into place. sqm 771
366 9.155 Providing and installation of acoustical wall panelling wood finish Slats made out of HDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts bothways.
Providing and installation of paintble acoustic wall panelling consisting of strand kerfed edge paint finished as approved by Engineer in charge. magnesite bonded wood fiber panels of size 600x2400x20mm having density 400kg/m3, weight 8- 20kg/m2 which is fixed to GI strut system. fastened to wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channel at 600mm centers. The Kerfed edge panels shall be then inserted into the H-spline against wall to perfect fit. 9.149.1 sqm 1578
Wt. 4.2 kg/m2 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-in-charge. (Frame work shall be paid for separately) sqm 1984
9.150.1 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-in-charge. (Frame work shall be paid for separately) sqm 3320
367 9.156 12mm thick commercial ply conforming to IS: 1328 BWR type. sqm 768
369 9.158 18 mm thick commercial ply conforming to IS: 1328 BWR type.
Providing and Installation of acoustic wall panelling consisting of Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x2400x20mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI strut system. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers. Kerfed edge Fabric wrapped panels shall be then inserted into the H-spline against wall to perfect fit. Providing and Installation of acoustic wall panelling consisting of Soak Cord of selected colours as approved by Engineer in charge, square edge Fabric wrapped wood fiber panels of size 600x1200x10mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI struts,Z bars. GI Z bars having 40mm height, thickness 1.2mm is first fixed behind the panels by identifying resin spots by using suitable fasteners.Clean exposed surfaces of wall and ensure walls are in plumb line before installing on wall (provide necessary packing shims if required). Soak cord square edge panels shall be slided into the Z bars fixed on wall. metre 203
Providing and installation of acoustic wall panelling consisting of Stretch NRC by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 10mm thick, rigid vinyl Stretch Tracks half wrap/ full wrap 25mm and Midseam 300mm centers. The fabric is stuck on the Align Tape (by removing the protective cover) at the same time as being stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module width would be 1600mm. Providing and Installation of wall panelling consisting of Square edge Magnesia core panels of size1100x2400x8mmmm having density 1000kgs/m3, weight 8kg/m2 installed by using GI Strut system. The GI struct system includes Cross channel having thickness 0.45mm, length 3600mm, knurled web 40, depth 10mm and equal flanges of 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c.The panels to be fixed on the cross channel with suitable fasteners. metre 208
370 9.159 Supplying and installation of magnesia block 66 mm thick drywall partition including Framework includes Floor/ Head GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed to floor and ceiling with suitable fasteners at 300mm centers staggered. Second layer of magenesia oxide block 8mm thick should be fixed other side of the frame work similar fashion as the first layer. 3mm gap should be maintained between boards.3 mm gap shall be filled with jointing compound. Magnesia oxide block shall have following physical charecterstics. sqm 1750
372 9.161 Using 8mm thick magnesia block sqm 1968
374 9.163 Using10mm thick magnesia block metre 342
Using12mm thick magnesia block
Add extra for providing and fixing Thermal insulation by providing 50mm thick synth PF having dencity 1000 GSM within the cavity held in position by using chicken wire mesh/ cross bracing/ pasting to the wall.
377 9.166 Providing and laying Gypsum panel partitions 100mm thick with water proof Gypsum panels of size 666x500x100mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor II level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2.
Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge: sqm 2026
9.158.1 Extruded section Profile size 48x40 mm. sqm 2490
379 9.168 Extruded section Profile size 42x50 mm.
Providing and fixing Panelled UPVC door shutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). Providing and fixing UPVC panelled door shutter UPVC 30 mm thick factory made PVC or UPVC door shutter made of styles and rails of a UPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge sqm 2026
Providing and fixing 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mmx25mm or less as per requirement with an average wall thickness of 1mm (± 0.3mm). PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. The Top and Bottom edges of the shutter are covered with an end-cap of the size 25mmx 11mm. Door shutter shall be reinforced with special polymeric reinforcements as per required specification and direction of Engineer-in- charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100mmx37mm with wall thickness 2mm (±0.2mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos. of plastic brackets of size 100mmx37mm, wall thickness 2mm (+0.2mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100mmx20 mm, and inserting 2 nos. tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-charge. sqm 2432
380 9.169 Providing and Fixing, factory made, PVC door frame made of PVC extruded sections of size 75mmx53 mm, having wall thickness 2.0mm (±0.2mm). Both verticals sides of the frame reinforced with PVC profile of cross section size 28mm x 30mm x2mm thickness (± 0.2 mm) and 75mmx200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos. and sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer-in-charge.
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115mm x 37mm with wall thickness , panels of 100 x 20 mm printed and laminated and inserting 2 nos. 6 mm dia. bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-Charge. RM 459
Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturer's specification and direction of Engineer-in- Charge. RM 720
Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall have a coat of steel primers and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing 9.166.1 RM 923
381 9.17 Plain PVC door shutters.
9.166.2 Pre laminated PVC door shutters. sqm 2250
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles and rails shall be of size 75 mmx30 mm having wall thickness 5 mm. The styles, top and bottom rails shall have one side wall thickness of 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge: sqm 3250
9.168.1 Non decorative finish. sqm 3693
9.168.2 Decorative finish (both side wood grained finish). sqm 4135
382 9.171 Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be p
aid separately) 9.169.1 sqm 3858
Single rebate (75 mm X 50 mm) 9.169.2 sqm 4417
383 9.172 Single rebate (100 mm X50 mm)
9.169.3 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. sqm 2423.65
Single or double rebate (125 mm X 65 mm) 5.12.2 sqm 3083.95
384 9.173 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 800
9.170.2 Per cm depth per cm width one m long. sqm 1300
385 9.174 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 2700
386 9.175 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter metre 517
35 mm thick WPC (Wood polymer composite) solid plain flush door shutter
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) . 9.171.1 sqm 2037
30 mm thick WPC (Wood Polymer Composite)solid decorative type flush door shutter 9.171.2 sqm 2142
388 9.177 35 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter sqm 313
389 9.178 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) metre 535
392 9.181 Providing and fixing factory made single extruded WPC (Wood polymer composite solid plain white color board for backing of cupboards and bathrooms/ kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-in-Charge. (Note: stainless steel screws shall be paid separately) sqm 4625
395 9.184 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 of approved steel primer, placed at grid made at 1.0 x 1.0 m sqm 27797
or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately.
396 9.185 Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5 mm (±0.2 mm) made out of single piece extruded PVC profile, with mitred cut joints and joint with 2nos of PVC bracket of size 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100mm long anchor fasteners complete, all as per manufacturer’s specification and direction of Engineer -in- charge 35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded soild PVC profiles, 5mm (±0.2mm) thick, having styles and rails (except lock rail) of size 95 mm x 35mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be 6091
397 9.186 tapered (on both side), having one side thickness of 15 mm solid core in middle of rail section integrally extruded, fixing the styles and rails with the help of solvent and self driven self tapping screws of 125 mm x11 mm, including providing 5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in- charge metre 435
Non decorative finish (matt finish). 9.176.2
Decorative finish (wood grained finish). Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. metre 422
Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat .Doorframe laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibreglass from all sides. MS stat shall be provided Providing and fixing to existing door frames. 30 mm thick glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames. metre 403
Providing and fixing door frame FRP 30mm thick fiberglass reinforced Plastic (F.R.P.) flush door shutter in different plain and wood inish made with fire retardant grade unsaturated polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. metre 434
Providing and fixing factory made Fibreglass Reinforced plastics (F.R.P.) chajja 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2nos. vertically and 1nos. horizontally 50x2mm thick M.S. flat with 12mm in built hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gelcoat U/V coating on Top for complete resistance from the extreme of temperature, weather and sunlight. Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating metre 99
not less than 120 gm/sqm) duly filled with vermuculite based of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in- charge (Dash fastener to be paid for separately). Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Engineer-in-charge with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). metre 130
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc. complete all as per direction of Engineer- in-charge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch and Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. Nos. metre 495
Providing and Fixing factory made UPVC door frame made of UPVC exturded sections, of size 65 mmx55 mm with wall thickness 2.0 mm (±0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mmx30 mm having wall thickness 2 mm (±0.2mm), including providing and fixing 3 nos. of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number and size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge. Providing and Fixing, UPVC factory made, white colour casement/sliding window and door made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8 mmx100 mm long fasteners, all complete as per direction of Engineer-in-charge. (Glazing, hardware hinges and fitting etc. to be paid separately.) metre 519
9.187.1 Casement Window (Outward/Inward opening) with hinge System. metre 178
9.187.1.1 Frame (50 mm x 50mm)
9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) metre 566
9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) metre 529
9.187.1.4 ‘T' Profile (one vertical length in between two shutters) (24mm x 34.5mm) metre 139
9.187.1.5 Glazing bead (12mm x 18mm) metre 178
9.187.2 Casement Window (With friction hinge and outward opening)
9.187.2.1 Sash (Style and Rail) (62 mm x 34 mm) metre 539
Casement Frame (67mm x 62mm) 9.187.2.2 metre 653
Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) 9.187.2.3 metre 139
Casement Glazing bead (35mm x 18 mm) Glazing bead (12mm x 18mm) metre 178
Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 each 321
Two Track Sliding Frame (67mm x 52mm) 9.187.3.2 each 369
Sliding window Sash (60mm x 44mm) 9.187.3.3 each 462
Sliding Interlock for Window(one vertical length in each shutter)(45.5mmx28 mm) 9.187.3.4 each 526
Sliding Glazing bead (35 mm x 18 mm) 9.187.4 each 636
400 9.189 Sliding Door (Two Track, 2/4 Shutters) each 214
403 9.192 Sliding Door Sash (80mm x 44mm) each 115
405 9.194 Sliding Interlock for Door(one vertical length in each shutter)(45.5mmx28mm)
9.187.4.4 Providing and fixing stainless steel (SS- 304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality with necessary stainless steel screws etc. as per direction of Engineer-in-charge. sqm 6798
400 x 19 x 1.9 mm Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete. sqm 5290
406 9.195 Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc. complete.
Providing and fixing steel roller for UPVC sliding window with necessary screws etc. complete.
Providing and fixing steel roller for UPVC sliding door with necessary screws etc. complete. Providing and fixing steel (white powder coated) crescent lock for UPVC sliding window/ door with necessary screws etc. complete. sqm 4860
407 9.196 Providing and fixing factory made UPVC white colour casement/casement cum fixed glazed windows comprising of UPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) sqm 7085
9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) sqm 7063
408 9.197 frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm).
9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). sqm 5060
9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) sqm 6880
9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both sqm 5134
having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) 9.194.6 sqm 6371
Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion 67 x 80 all having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for sqm 5913
409 9.198 fixing frame to finished wall, plastic packers, plastic capsof approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 4332
Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.196.1 sqm 3532
410 9.199 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).
Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. sqm 3676
9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 3810
9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). sqm 4361
9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). sqm 5617
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension.(Area of window above 1.75 sqm).
Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x62mm both having wall thickness of 2.3 ±0.2 mm and single glazing bead/ double glazing bead of appropriate dimension.(Area of window above 1.75sqm) Providing and fixing factory made UPVC white colour sliding glazed window above 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. sqm 2250
9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm). sqm 3229
Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly sqm 3693
reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section madAfter fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & directionof Engineer- in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: - For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. sqm 3461
Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 10.00 sqm). 9.199.2 sqm 3339
Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto10.00 sqm). 9.199.3 sqm 3171
Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) 9.199.4 sqm 3005
415 9.204 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)
Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture PVC beading as gap insert below top and bottom rail joined together using solvent cement adhesive. An additional 5mm thick Prelaminated PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ channel using PVC solvent cement adhesive etc. complete as per direction of Engineer-in- charge. Manufacturer’s specification and drawing. 30 mm thick pre laminated PVC door shutters. sqm 1953
Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet(Single Extruded)with density not less than 600 kg/cum, conforming to IS:2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO:9001 -2000 certified company. 9.201.1 sqm 1772
24 to 25 mm thick plain solid PVC flush door shutter 9.201.2 sqm 1532
416 9.205 28 to 30 mm thick plain solid PVC flush door shutter sqm 401
417 9.206 Providing and fixing factory made pre laminated solid PVC flush door shutters 28 to 30 mm thick made from co-extruded three layer rigid PVC foam sheet with density not less than 600 kg/cum, conforming to IS: 2380 part 14, for screw holding strength and outer layers laminated on both sides by laminated sheet with density not less than 1400 kg/cum, lamination shall be at the manufacturing process itself and manufactured by an ISO: 9001-2000 certified company.
9.202.1 1mm thick laminated sheet
9.202.2 0.12 mm thick laminated sheet sqm 5920
Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) laminated type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens with well matched 3mm thick commercial 3ply veneering consisting of vertical grains, cross bands withing frame of door/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS: 2202. The rate shall be inclusive of all material and labour complete and as per specification and dirction of Engineer-in-Charge. 9.203.1 sqm 7212
35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.2
35mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 0.12 mm thick laminated sheet sqm 6512
25mm thick (for cupboard) including 3 nos. 75mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) non decorative type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens (strips) and frame of kiln seasoned and chemically treated, finger jointed cross bands including all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50cm. Each shutter shall be factory made to the exact opening size within frame of doors/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and confirmity with IS:2202.
9.204.1 0.12 mm thick laminated sheet sqm 7550
35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary. 9.203.1 sqm 9960
419 9.208 30mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws.
9.204.3 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. sqm 3366
Deduct for not providing 2nd class teak wood batten lipping in factory made shutters i.e. item no 9.203 and 9.204. Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. sqm 3268
9.206.1 Acrylic Solid Surface sheet – Glacier white designer whit sqm 3056
420 9.209 9.206.1.16 mm thick sheet 9.206.1.212 mm thick sheet9.206.2MAcrylic Solid Surface sheet - Any Solid colours/Hospital use Medi Blue 9.206.2.1 9.206.2.29.206.3)Acrylic Solid Surface sheet - Any other 9.206.3.1 9.206.3.2hProviding and fixing of 8mm thick non asbestos multipurpose board reinforced with cellulose fibers for wall cladding will consist of following operations:1. Fixing of a layer of 6mm Moisture/fire Resistance Heavy Duty fibre cement Boards over above mentioned 6 mm heavy duty fibre cement board with the help of 25mm self drilling, self tapping Fibre Cement screws @ 300mm c/c. All external corners are to be protected with the use of suitable corner profile of GI or PVC. All above operation is to be done in order and as directed by Engineer-in-Charge.(frame work to be paid separately).1Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS: 15380(2003), eco-friendly, termite resistant, borer free, anti warping phenol formaldehyde (PF), decorative designe moulded or rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company gujcon, century, green shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B).9.208.135 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws.9.208.230 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws.9.208.3k25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws.«Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), non decorative designe moulded and labor complete as per specifications and direction of engineer-in- charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B).9.209.19.209.230 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws9.209.3úProviding and fixing IS marked factory made High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), 2 and 4 Panel designe moulded or plain construction with particle board shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B).9.210.19.210.2 HDF decorative prelaminated pine wood panel door with glass / wiremash:- Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B).9.211.19.211.2ÞProviding and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), . The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B).9.212.19.212.232 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws.9.212.3k25 mm thick ISI marked heavy weight nickel plated bright finished M.S. Piano hinges with screws.Non Decorative Pine Wood Flush Door:- Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer- in-charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:22029.213.135 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws.9.213.230 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws.9.213.3ª25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws.ÚProviding and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned sheet shall be as per IS: 2046 type S of approved quality. Each shutter shall be factory made to the exact size (opening) within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, bat
ch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in- charge.Ê@Ì=9.214.135 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws.9.214.230 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws.9.214.3 Providing and fixing ISI marked factory made flush door shutters conforming to IS:2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned within frame of doors/cupboards and shall be stamped by the manufacturer to display nameof manufacturer, batch number of product and conformitywith IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in-charge.9.215.19.215.29.215.3©25mm thick (for cupboard) including 3 nos. 75 mm long ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws.QProviding and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) veneer decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) s and commercial grade face veneers on both outer faces of shutters including kiln seasoned and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202.Þ@à=9.216.19.216.29.216.3fProviding and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides,made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastne with necesary stainless steel screws, all complete as per direction of Engineer-in-charge.Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity.Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge_Fire resistant Providing and fixing fire resistant door door frame (2 hr fire rating) frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zink coating not less than 120gm/m2) suitable for mounting 120 min fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool insulation provision of GI. Anchor fasters 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made Template for ss Ball Bearing Hinges of size 100x89x3 mm for fixing of fire rated glazer shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the direction of Engineer-in-charge.(Coast of ss ball beating hinges is excluded). Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with u clip, EPDM rubber / neoprene gasket complete. 9.220.1d S.S. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. ]Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 minutes Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/ m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016 and directions of Engineer - in- charge.Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm 9Providing and fixing of ISI marked Un- insulated fire rated GI Sheet doors conforming to FD 120 classification of IS 3614 :2021 with fire rating of 120 minutes integrity. The factory manufactured door frame and shutter assembly shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns.The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021. The Door frame shall be single rebate grooved profile of size minimum 125mm x 55mm made out of 1.50mm (18gauge) minimum thick galvanized steel sheet. Frames shall be butt / mitred joint and field assembled with bolting system. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip of size 10x4mm. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastener with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonry wall opening. Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from 1.2mm (18gauge) thick galvanised steel sheet. The infill material shall be proprietary insulation material. All doors shall be factory prepared 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. sqm 2175
for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x89x3 mm along with all suitable hardware). Vision lite size 185 *285 or 300x400 mm (max area 0.12sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 2021 with a clipon arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness with min. 15mm width all-around on either face. ûProviding and fixing of Fully Insulated Non Metallic Wooden doors as per IS 3614:2021, for 120 min integrity & 120 min insulation. The door is made out of thoroughly seasoned hard wood. The moisture content of any material used in the construction of wooden composite fire door sets comprises of both frame and shutter shall not be more than 15% approx. in accordance with IS 287. The fire door must have earlier test evidence as per IS/ISO 3008-1. It must have successfully tested from CBRI Roorkee/ NABL accrediated lab. Door and frame shall be finished with fire retardent primer FR880. All accressesories like hardware, fire seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021. Every door must carry a label confirming to type of door & its fire rating. Door frame shall be Single rebate profile of section 120 x 60 mm made out of Hard wood - Red meranti / Ivory Coast (2nd class ) or equivalent having density of 550-600 kg/m3 approx. with factory made groove of Âsuitable size so as to accomodate intumuscent Fire seal of size 20x4mm . An EPDM seal also to be provided in the frame to check spread of smoke. The frame must be primed with Fire retardant primer FR880. The frame to be fixed to fire exit opening with minimum 10 nos. 10 mm dia and minimum 120 mm long HDG (hot dip galavanized) headed screws with polyamide sleeves. Wooden shutter must be of minimum 50 mm of thickness finished with commercial ply on both faces. If required, the Commercial ply may be replaced with teak ply or may be pasted with 1mm thick Laminate on both faces in desired regular SF grade . The composite thickness of the core insulation will be 37mm consists of minimum 10mm thick Calcium Silicate boards and treated wool Insulation material. The calcium silicate board must have Density not more than 90kg/m3 , having thermal conductivity 0.15W/mK . The shutter should be provided with heat activated intumescent fire seal strip of size 20mm x 4 mm mounted in the suitable grooves all three sides except bottom provided on Exposed OR concealed wooden lipping .The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges along with all suitable hardware.Vision lite size 200x300 mm or 150 x 400mm(max area 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021. Every Glass pane must carry a permanent marking of its glass manufacturer. JSupply and installation of termite proof, moisture/fire resistant 8mm thick cement bonded particle board confirming to IS: 14276: 1995 in wall panel on structure to form wall/partition wall on external face of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 125 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27mm and 37mm, at 1200 mm centre tocentre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre fixed the self- drilling/tapping screws/fasteners of approved make. as per the directions of Engineer-in-Charge.Providing and fixing 2 Hrs fire rated acoustic wooden Door of approved make, the door and whole system and criteria shall be comply with IS: 3614 2021, also the door shall be acoustic suitable to achieve minimum 35db sound reducing properties, the system shall comprising of door frame, shutter with hardware and other accessories & ancillary material as per approved manufacturer specification, as given in description/technical specification and as directed Engineer-In-Charge. Door Frame: The grooved Frames for Fire resistant door shall be Hardwood (Red merandi), densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel as per IS: 401 and kiln seasoned to moisture level, the moisture content of any material used in the construction of wooden fire rated door, shall not be more than 15 percent, in accordance with IS 287. Wood dry density shall be above 450kgs/cum, The size of frame shall be min. 140 X 90 mm or as per approved manufacturer, with approved intumescent strip of size 20mmx4mm or as approved manufacturer to be concealed in the groove of the Frame for fire and smoke sealing, etc. Frame rebate shall be as per manufacturer standard, the frame to be fixed with anchor fastener / dash fasteners or as per approved manufacturer and as approved by EIC. Complete all as per direction of Engineer in Charge.Shutter: The thickness of shutter shall be 77-85mm (ASBESTOSWFREE) with commercial ply on both faces. Acoustic Door Shutter shall be complying with fire performance - FD 120 as per IS: 3614-2021. The frame work to make shutter shall be hardwood made (Red merandi) , densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel as per IS:401 and seasoned to moisture level, the moisture content of any material used in the construction of wooden fire rated door, shall not be more than 15 percent, in accordance with IS 287. Wood dry density shall be above 450kgs/cum, The shutter system shall be comprising of 2 x 12 mm thick noncombustible Calcium Silicate boards, approved in filled material with appropriate density as per IS 3614, other approved infill material as acoustic insulation filler, interlayer Rubber sheet, Fire retardant or approved plywood, internally lipped with hardwood beading and all around shutter etc. shall be as approved by EIC and as per approved manufacturer. The frame work, lipping shall be fire r etardant primer/paint finish. The Intumescent seals shall 20 mm x 4 mm, the seal affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom. Rebate shall be as per manufacturer standard, The shall be finished with 1 mm thick approved laminate on both side, All complete as per approved manufacturer standard and as directed by EIC. Supplying & Installation of Non-Woven 100% Polyester Fibre Acoustic wall Panels made from polyester short fibre. It is prepared by needle punching on multi folded polyester fabric sheets is lightweight and flexible along with excellent tension/compression stiffness. The panel can be easily cut into any desired shape pattern and V-Grove pattern (arranged by carding process). The final material consists of a three-dimensional network structure with breathable open cells. fixed with Rubber adhesive.Physical Properties×Physical Properties 1. Eco-friendly 2. 100% recyclable 3. Moisture proof,Humidity Resistance 4. Flammability tested as per IS 11871 A 5. Thickness 10 mm 6. NRC: High Performance 0.60 to 0.90 7. Density 180-200kg/m3 êProviding & Fixing PVC ceiling system profile panel with click system inter sqm 2075
慰敮楳敺㐠〰洰硭㐳洰硭洱敲楳瑳湡散琠敷瑡敨数晲捥⁴楦楮桳椠潷摯朠慲湩☠猠汯摩挠汯畯慭湩整慮据牦敥删獥獩慴据潴眠慥桴牥琠畲祬愠瑮慢瑣牥慩眠瑩摥敧瀠潲楦敬䨠琭楲湯瀠牥灩敨祲☠挠湥整牰景汩ⵔ牴浩椠慰敮潪湩⁴潃灭敬整匠獹整琠戠楦數湯†⹇⹉牦浡睥牯景挠楥楬杮猠捥楴湯愠⁴㔴‰浭搠獩慴据楷桴攠瑮牥猠捥楴湯猠獵数摮摥戠特潯祢䜠䤮湡汧慨杮牥椠牰灯牥氠湩…敬敶瑥潣灭敬整Ʈ倁刀伀䐀唀䌀吀 匀倀䔀䌀䤀䘀䤀䌀䄀吀䤀伀一匀㨀䴀攀攀琀猀 漀爀 攀砀挀攀攀搀猀 琀栀攀 猀琀愀渀搀愀爀搀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 漀昀 ⠀䄀匀吀䴀 䐀ⴀ㐀㐀㜀㜀⤀ 愀渀搀 椀琀猀 爀攀昀攀爀攀渀挀攀搀 搀漀挀甀洀攀渀琀猀⸀䤀洀瀀愀挀琀 爀攀猀椀猀琀愀渀挀攀㨀 一漀 搀攀昀漀爀洀愀琀椀漀渀 漀戀猀攀爀瘀攀搀⸀ ⠀吀攀猀琀攀搀 愀琀 㔀 䰀䈀匀⤀吀攀渀猀椀氀攀 猀琀爀攀渀最琀栀Ⰰ 䴀倀愀㨀 㸀㌀㜀⸀ 吀攀渀猀椀氀攀 洀漀搀甀氀甀猀Ⰰ 䴀倀愀㨀 㸀㈀ 匀甀爀昀愀挀攀 搀椀猀琀漀爀琀椀漀渀㨀 一漀渀攀 愀琀 ㈀ 䘀 匀焀甀愀爀攀渀攀猀猀㨀 㰀⼀㠀ᴀ†漀昀 猀焀甀愀爀攀 䰀攀渀最琀栀㨀 圀椀琀栀椀渀밀ᴀ†漀昀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 䰀漀挀欀 挀漀渀琀爀漀氀㨀 䌀漀洀瀀氀椀攀猀 䌀漀氀漀爀 䌀栀愀渀最攀㨀 㰀㈀ 最爀愀礀猀挀愀氀攀猀 ⠀㘀 栀爀猀 甀渀搀攀爀 ㈀ 圀⼀洀㈀ 唀嘀 爀愀搀椀愀琀椀漀渀 愀琀 㔀 搀攀最爀攀攀猀⤀ꔀ牐癯摩湩…楆楸杮䘠扡楲捁畯瑳捩圠污慐敮楬杮匠獹整景猠穩㈱〰浭洮硡浩浵椠楷瑤…敌杮桴愠敲畱物摥愠数楳整䌠湯楤楴湯眠瑩㔲浭琠楨正猠牴瑥档栠污 畦汬眠慲⁰楲楧楶祮牴捡獫琠敢映硩漠硥獩楴杮猠牵慦散眠瑩噐⁃湩敳瑲愠摮猠牣睥獡爠煥極敲慰瑴牥湩瀠湡汥愠敐敲畱物摥洠摯汵㈠洵桴捩捡畯瑳捩爠捯睫潯慰景ㄠ〰杫搠湥楳祴䘠物汃獡ⵁ‱獡瀠牥䔠⁎㌱〵ⰱ丠䍒㰠⸰〷琠敢映汩湩瀠湡汥映硩摥戠⁹畲扢牥愠桤獥癩䄠灰潲敶慦牢捩琠敢朠楲⁰湩猠牴瑥档琠慲正戠⁹畴正湩潴汯潴洠歡慰敮湩瀠潲数楬敮愠摮氠癥汥眠瑩牷湩汫牦敥映湩獩吠敨猠牴瑥档琠慲正挠敲瑡⁖牧潯敶⼠䈠瑵⁴潪湩⁴湩攠捡慰敮䌠浯汰瑥慥数慳楴晳捡楴湯戠⁹湅楧敮牥椠档牡敧봮牐癯摩湩…楆楸杮䰠浡湩瑡摥眠潯楦楮桳ㄠ‹浭琠楨正䄠潣獵楴慣潌癵牥慷汬瀠湡汥猠獹整慭敤映潲㜱浭琠楨正☠㈠㐴洰敌杮桴䑍⁆敐晲牯瑡摥朠潲癯摥倠湡汥眠瑩ⴲ洴桴捩牧潯敶…〱ㄭ洳桴捩楐捴眠瑩洲桴捩慢正湩景倠汯敹瑳牥楦牢剆朠慲敤䄠潣獵楴慣敆瑬倠湡汥琠敢映硩摥眠瑩潔杮敵愠摮朠潲癯牡慲杮浥湥⁴楦數湯愠畬業畮档湡敮瑡㜠〵浭搠獩慴据数灲湥楤畣慬潴瀠湡汥眠瑩⹇⹉挠楬獰汁浵湩浵挠慨湮汥琠敢映硩漠⹇⹉匠捥楴湯漠楳敺㐠洵硭㈱浭へ㤮‰浭琠楨正椠瑮牥敭楤瑡档湡敮㔠‰浭琠楨正☠㐠‸杫搠湥楳祴删捯睫潯楆敲挠慬獳䄠ㄭ愠数久㌱〵‱剎⁃⸰㠸琠敢映汩湩愠物朠灡琠敨琠瑯污愠潣獵楴慣慰敮楬杮猠獹整楦楮桳摥椠牰灯牥氠湩…敬敶愠数慳楴晳捡楴湯戠⁹湅楧敮牥椠档牡敧浭琠楨正椠瑮牥敭楤瑡档湡敮㔠‰浭琠楨正☠㐠‸杫搠湥楳祴删捯睫潯楆敲挠慬獳䄠ㄭ愠数久㌱〵‱剎⁃⸰㠸琠敢映汩湩愠物朠灡琠敨琠瑯污愠潣獵楴慣慰敮楬杮猠獹整楦楮桳摥椠牰灯牥氠湩…敬敶愠数慳楴晳捡楴湯戠⁹湅楧敮牥椠档牡敧欮牐癯摩湩湡楦楸杮ㄠ‸浭琠楨正眠污慰敮楬杮眠瑩潣浭牥楣污瀠祬栠癡湩湯楳敤瘠湥敥洴桴捩䤨䥓洠牡敫卉㨠ㄠ㠴㈴Ⱙ椠据畬楤杮倠⁕潐楬桳椠据畬楤杮挠獯⁴景爠煥極敲畃畏獴捳敲ⱷ瀠楲業杮挠慯ⱴ匠慣晦汯楤杮映牯愠汬栠楥桧獴潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲吠楨瑩浥猠慨汬†敢†硥捥瑵摥†湯祬†晡整琠敨†牰潩灡牰癯污漠桃敩湥楧敮牥鈮牐癯摩湩湡楦楸杮㈠‴浭⠠㠱浭⬠㘠洠⥭琠楨正挠浯敭捲慩汰⁹䤨䥓洠牡敫卉›㐱㐸⤲眠污慰敮楬杮慨楶杮㘠浭朠潲敶癯牥㘠浭戠慯摲䀠ㄠ〰洠楄瑳湡散漠慷汬瀠湡汥湩Ⱨ映湩獩敨楷桴䐠捥潐楬桳愠数牁档瑩捥畴慲牤睡湩潣灭敬整眠瑩敮散獳牡⁹捳敲獷潣灭敬整愠数楳整爠煥極敲敭瑮愠摮搠物捥楴湯漠湥楧敮牥椭档牡敧桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥Ɯ倀潲楶楤杮愠摮映硩湩潄牯瀠湡汥湩㠱浭琠楨正挠浯敭捲慩汰⁹湩汣摵湩㈱浭挠浯敭捲慩汰⁹潦敒慢整眠瑩湯楳敤瘠湥敥洴桴捩䤨䥓洠牡敫卉㨠ㄠ㠴㈴Ⱙ眠瑩啐倠汯獩潣灭敬整眠瑩敮散獳牡⁹捳敲獷愠数牁档瑩捥畴慲牤睡湩潣灭敬整眠瑩敮散獳牡⁹捳敲獷潣灭敬整愠数楳整爠煥極敲敭瑮愠摮搠物捥楴湯漠湥楧敮牥椭挠慨杲吠楨瑩浥猠慨汬戠硥捥瑵摥漠汮⁹晡整桴牰潩灡牰癯污漠桃敩湥楧敮牥∮牐癯摩湩湡楦楸杮眠污慰敮楬杮ㄠ洸桴捩潣浭牥楣污瀠祬眠瑩敄潣倠汯獩湩汣摵湩潣瑳漠敲畱物摥䌠瑵伭瑵ⱳ猠牣睥牰浩湩潣瑡捓晡潦摬湩潦污敨杩瑨挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥椭䌠慨杲桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥9倀潲楶楤杮愠摮映硩湩〵浭堠㈠‵浭爠晡整楷桴搠捥潰楬桳刀瑭剳牐癯摩湩湡楦楸杮㜠洵⁘㔳浭洠晤爠晡整楷桴㐠浭琠楨正瘠湥敥湡⹐⹕倠汯獩M倀潲楶楤杮愠摮映硩湩〵浭堠㈠‵浭爠晡整楷桴㐠浭琠楨正瘠湥敥湡啐瀠汯獩倀潲楶楤杮愠摮映硩湩㔶洠灓捥慩敤楳湧挠慨捲慯潍汵楤杮桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥倀潲楶楤杮愠摮映硩湩㠳洠灓捥慩敤楳湧挠慨捲慯潍汵楤杮桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥倀潲楶楤杮愠摮映硩湩㈲洠灓捥慩敤楳湧挠慨捲慯潍汵楤杮桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥ý倀潲楶楤杮愠摮映硩湩卉⁉慭歲摥倠敲業浵焠慵楬祴䄠瑮煩敵䈠慲獳琠睯牥戠汯⁴䈨牡敲祴数 楷桴渠捥獥慳祲猠牣睥瑥挠浯汰瑥䄠汬挠浯汰瑥獡瀠牥搠物捥楴湯戠⁹湥楧敮牥椠档牡敧桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥㐀〵洠潬杮搠慩ㄠ洰፭牐癯摩湩湡楦楸杮倠敲業浵焠慵楬祴䄠瑮煩敵䈠慲獳猠楬楤杮搠潯潢瑬ⱳ䤠䥓洠牡敫潴爠煥極敲潣潬牵漠桳摡ⱥ眠瑩畮獴愠摮猠牣睥瑥挠浯汰瑥汁潣灭敬整愠数楤敲瑣潩祢攠杮湩敥湩挠慨杲吠楨瑩浥猠慨汬戠硥捥瑵摥漠汮⁹晡整桴牰潩灡牰癯污漠桃敩湥楧敮牥ᐮ〴‰浭氠湯楤㘱浭×倀潲楶楤杮愠摮映硩湩牐浥畩畱污瑩⁹湁楴畱牂獡慨摮敬楷桴渠捥獥慳祲猠牣睥瑥䄠汬挠浯汰瑥獡瀠牥搠物捥楴湯戠⁹湥楧敮牥椠档牡敧桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥㔀〶洠潬杮搠慩㈠洵慨摮敬ť倀潲楶楤杮愠摮映硩湩牐浥畩畱污瑩⁹湁楴畱牂獡票牤畡楬潤牯挠潬敳栨癡湩牢湡潬潧眠瑩卉ⱉ䤠⁓›㔳㐶浥潢獳摥漠桴潢祤潤牯眠楥桧⁴㔱‰⹋⁇湡潤牯眠摩桴甠⁰潴㜠〰洠⥭楷桴渠捥獥慳祲愠捣獥潳楲獥愠摮猠牣睥瑥䄠汬挠浯汰瑥獡瀠牥搠物捥楴湯戠⁹湥楧敮牥椠档牡敧桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥ď倀潲楶楤杮愠摮映硩湩牐浥畩畱污瑩⁹湁楴畱牂獡㈱‵浭洠牯楴敳氠瑡档眠瑩湯牴潢瑬眠瑩桴敲敫⁹楰牥愠摮愠瀠楡景氠癥牥栠湡汤獥漠灡牰癯摥焠慵楬祴眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥ā倀潲楶楤杮愠摮映硩湩牐浥畩畱污瑩⁹慓楴楦楮桳摥ㄠ㔲洠潭瑲獩慬捴楷桴漠敮搠慥牴潢瑬愠摮愠瀠楡景氠癥牥栠湡汤獥漠灡牰癯摥焠慵楬祴眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整桔獩椠整桳污敢攠數畣整湯祬愠瑦牥琠敨瀠楲牯愠灰潲慶景䌠楨晥攠杮湩敥̜䜀⁉敭慴潤牯栠癡湩潷摯湥映湩獩桴潲杵畳汢浩瑡潩牰湩楴杮眠瑩潰摷牥挠慯楴杮瀭潲楶楤杮愠摮映硩湩景洠瑥污搠潯楷桴漠瑵牥映慲敭牆浡楓敺㤠砹㤵洠畳瑩扡敬猠捥楴湯映牯搠潯慭敤漠瑵映潲牰獥敳潦浲摥䜠卐⁐桳敥⁴景琠楨正敮獳ㄠ㈮䌠湯楦浲湩潴䤠㉓㜷 Acrylic Solid Surface sheet – Glacier white designer whit sqm 1975
421 9.21 . With honey necessary cut-outs of locks and handle etc. 42mm thick Sandwich panel door made from 0.8 mm thick GPSP Sheet duly filed with honeycomb paper core 40/12 for sound absorbing and provide more strength to door shutters and fixing with necessary stainless steel ball bearing hinges. The complete shutter & Frame (inside & outside) shall be wooden finish through sublimation printing with powder coating outer frame will be grouted on wall with Anchor fastener of suitable size and quantity as per direction of engineer-in-charge.SQM÷Providing and fixing commercial ply conforming to IS: 1328 BWR type of approved brand for frame work of boxes, shelves, racks, Amirah, cupboard and drawer etc. including necessary nails, screws etc. Complete as per direction of Engineer-in-charge.'9 mm thick BWP grade commercial plywood-12 mm thick BWP grade commercial plywood.18 mm thick BWP grade commercial plywood -25 mm thick BWP grade commercial plywoodProviding and fixing Stainless steel tubular H handle bar (Grade 304) with SS screws etc .complete set as per direction of Engineer-in-Charge.25 mm outer dia & 300 mm longEach Set32 mm outer dia & 450 mm long32 mm outer dia & 600 mm long¹Add Extra for Providing and Fixing, UPVC factory made, coloured / other than white colour casement/sliding window and door (for item no. 9.187, 9.194, 9.195,9.196, 9.197, 9.198, 9.199)30% of Respective item9.258.1\Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.âStructural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.BStructural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.ßProviding and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required.Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S.gusset plates at the junction and corners 25mm dia pulley,40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer.Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.;Using M.S. angels 40x40x6mm for diagonal bracesDUsing flats 30x6mm for diagonal braces and central cross piece.Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. <80x1.25mm M.S. laths with 1.25 mm thick top cover.980x1.20 mm M.S. laths with 1.20 mm thick top cover.980x0.90 mm M.S. laths with 0.90 mm thick top cover.vExtra for providing suitable mechanical device chain and crank operation for operating rolling shutters.3Exceeding 10.00 sqm and upto 16.80 sqm in the area.Exceeding 16.80 sqm in area.¾Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured).AProviding and fixing ball bearing for rolling shutters.¥Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment).ÎFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size).sFixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately).ïExtra for providing and fixing steel beading of size 10x10x1.6mm (box type) approved shape and section with screws instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units.Providing and fixing L-iron or T-iron frames for doors, windows and ventilators of mild steel L-section or T-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge:<Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1>Fixing with adjustable lugs with split end tail to each jamb. 10.12.1.2tFixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately).:Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 10.12.2.2@Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 10.12.3.2<Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 10.12.4.2:Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 10.12.5.2@Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 10.12.6.2>Providing and fixing M.S. Tubular frames and shutters or frames only or shutters only for doors, windows, ventilators and cupboard with any sections, made of 1.60 mm or 1.25 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size as per drawing, including fixing of necessary butt hinges, stays and screws and applying a priming coat of approved steel primer excluding cost of all fittings such as handles, tower bolts, sliding door bolts, latches etc. and panels. 10.13.110.13.2=Steel work in built up M.S. tubular section (round, s
quare or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.14.1Hot finished welded type tubes10.14.2 Hot finished seamless type tubes10.14.3?Electric resistance or induction butt welded tubes.RDesign, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats of Epoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code.ßProviding and fixing M.S. fan clamp type I or II of 16mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete.ÆProviding and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing.hProviding and fixing mild steel round holding down bolts with nuts and washer plates complete.?Providing and fixing bolts including nuts and washers complete.:Providing and fixing M.S. rivets of sizes in position.hWelding by gas or electric plant including transportation of plant at site etc. complete.cmÕSteel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.22.1In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.10.22.2RIn gratings,frames, guard bar, ladder,railings, brackets,gates and similar works. ïProviding and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer.10.23.1 M.S. tube.10.23.2 E.R.W. tubes.uProviding and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge.º@»=10.24.110x60 mm10.24.210x80 mm10.24.3 10x120 mm10.24.4 10x140 mm10.24.510x160mm5Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete.10.26.1`Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides10.26.2bStainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.¡Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete.10.27.1With 4.0 mm thick glass panes10.27.2With 5.50 mm thick glass panes10.27.3HWith 1mm thick mild steel sheet i/c 10x10x1.6mm box beading.10.27.4\With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm box beading.10.27.5BWith 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading.10.27.6With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading.10.27.7With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading.10.27.8With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading.UAdd extra for providing and fixing froasted glass instead of float glass.10.28.1With 4.0 mm thick glass panes.10.28.2With 5.5 mm thick glass panes.Supplying at site:10.29.1wR.C.C. Standards post/ struts/rails/ poles of mix 1:1.5:3 (1 cement : 1.5 sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge including fixing (cost of earth works in excavation, concrete works in foundation to be paid separately).10.29.24Angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (cost of earth work in excavation and concrete work in foundation to be paid separately)10.29.3Supplying at site -Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming painting to be paid for separately).lSupplying and fixing turn buckles and straining bolts for barbed wire fencing. (Labour rate only).óFencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) with GI barbed wire.ÜFencing with barbed G.I. wire angle iron post placed fitted to at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used. Fixing Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, provided with we 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. sqm 3789
lded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, painting, earth work in excavation and cement concrete to be paid for separately). (Labour rate only) . mProviding and fixing G.I. or PVC coated G.I.wire chain link fabric fencing of required width and mesh size including strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer- in-charge. (Cost of post, painting earthwork & c.c. to be paid separately) 10.34.1Made of G.I. wire.10.34.2jMade of G.I. wire, PVC coated to achieve outer dia. not less than 5mm in required colour and shade.úProviding and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and washers as required complete, with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer-in- Charge. (cost of post painting earth work & C.C. to be paid separately)©Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). »Providing and fixing of ISI marked insulated fire rated GI Sheet doors conforming to FD 120-PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The Door frame shall be single rebate grooved profile of size minimum 125 mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip of size 10x4mm. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonary wall opening.£factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 89x3 mm along with all suitable hardware (Payable in extra item). Vision lite size 185x285 (max area up to 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clip on arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness with min. 15mm width al around on either face. Every Glass pane must carry a permanent marking of its glass manufacturer.dProviding and fixing of factory make air tight casement windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, colour coated/ powder coated (base steel as per IS 513 of D" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) outer frame section 46x52x0.58 mm, shutter section 46x46x0.58mm, mullion section 46x70x0.58mm, beading section 18x25x0.58 mm, windows panelled without glazing (glazing shall be paid separately as per SOR rate) with EPDM (Ethyl Propylene Diamine Monomer) gasket and the sections cut to length mitre joined with corner bracket centre mullions fixed using mullion cap and with handle made of powder coating high grade aluminum with nylon receiver, corner brackets made of CRCA (Cold Rolled Close Annealed) with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 10.38.1Openable window10.38.2 Fixed windowsProviding and fixing of factory make single rebate openable/fixed windows made of roll formed galvanized pre- pained steel with epoxy primer of 5-7 microns thick Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. sqm 3643
422 9.211 , finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick) heavy duty pivot hinges per shutter and window fitted without glazing including 10mm square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto
湡‵浭眠摩桴椠敢睴敥瑳敥牦浡湡摡慪散瑮删䍃 䈠楲正 匠潴敮†潷歲†祢†牰癯摩湩敷瑡敨楳楬潣敳污湡⁴癯牥戠捡敫潲景愠灰潲敶†畱污瑩⁹†獡†瀠牥†愠捲楨整瑣牵污搠慲楷杮愠摮†楤敲瑣潩漠䔠杮湩敥湩档牡敧挠浯汰瑥畍汬潩慣獰洠摡景朠慬獳映汩敬祮潬Ɱ映慲敭楦數潴琠敨挠湯牣瑥洯獡湯祲眠污祢洠慥獮漠敳晬攭灸湡楤杮猠牣睥䤠据畬楤杮映汩楬杮琠敨朠灡甠瑰‵浭搠灥桴愠摮㔠洠楷瑤湩戠瑥敷湥猠整汥映慲敭愠摮愠橤捡湥⁴䍒⽃䈠楲正 瑓湯潷歲戠⁹牰癯摩湩敷瑡敨楳楬潣敳污湡⁴癯牥戠捡敫潲景愠灰潲敶畱污瑩⁹獡瀠牥愠捲楨整瑣牵污搠慲楷杮湡楤敲瑣潩景䔠杮湩敥湩挭慨杲潣灭敬整ਮ⸰㤳ㄮ伀数慮汢楳杮敬爠扥瑡楷摮睯⸰㤳㈮䘀硩摥猠湩汧敲慢整眠湩潤뙷牐癯摩湩†湡†楦楸杮†漠†慦瑣牯⁹†慭敫搠畯汢†敲慢整†眠湩潤獷†洠摡†景††爠汯潦浲摥†朠污慶楮敺牰ⵥ慰湩整瑳敥楷桴攠潰祸瀠楲敭景㔠㜭洠捩潲獮琠楨正楦楮桳瀠楡瑮摥†楷桴†瀠汯敹瑳牥†慰湩⁴漠ㄠⴲ㘱洠捩潲獮琠楨正愠摮戠捡潣瑡摥眠瑩污祫慢正牥†㔠㜭†洠捩潲獮†琠楨正†漠†潰摷牥挠慯整眠瑩瀠牵瀠汯敹瑳牥†潰摷牥†灵†潴㔠ⴰ〶†洠捩潲獮†琠楨正†††楦瑴摥†甠楳杮†䔠䑐⁍䔨桴汹††牐灯汹湥†䐠慩業敮††潍潮敭⥲朠獡敫獴†湩汣摵湩映硩湩眠湩潤獷†湩†桴潣据敲整洯獡湯祲†慷汬†祢†敭湡漠猠汥ⵦ攠灸湡楤杮††猠牣睥ⱳ††椠据畬楤杮††ㄠ洰煓慵敲†慢獲†敷摬摥†潴†砶㈱浭†汦瑡†瑡†楤瑳湡散ㄠ〵浭挠振⠠楰捴⥨†瑥䤠据畬楤杮映汩楬杮琠敨朠灡甠瑰‵浭搠灥桴愠摮㔠洠楷瑤湩戠瑥敷湥猠整汥映慲敭愠摮愠橤捡湥⁴䍒⽃†牂捩⽫†瑓湯眠牯戠⁹瀠潲楶楤杮眠慥桴牥猠汩捩湯猠慥慬瑮漠敶慢正牥爠摯漠灡牰癯摥†焠慵楬祴†愠†数†牡档瑩捥畴慲牤睡湩獧†湡搠物捥楴湯†景†湅楧敮牥椭挠慨杲潣灭敬整⸮⸰〴ㄮ伀数慮汢潤扵敬爠扥瑡楷摮睯⸰〴㈮䘀硩摥搠畯汢敲慢整眠湩潤꩷牐癯摩湩†湡†楦楸杮†漠†慦瑣牯⁹†慭敫映硩摥氠畯敶獲映扡楲慣整牦浯爠汯潦浲摥猠捥楴湯洠摡漠朠污慶楮敺瀠敲瀭楡瑮摥猠整汥†楷桴†灥硯⁹瀠楲敭漠㔠㜭†業牣湯桴捩Ⱬ映湩獩慰湩整楷桴愠瀠汯敹瑳牥瀠楡瑮漠ㄠⴲ㘱†業牣湯琠楨正†湡戠捡挠慯整楷桴†污祫戠捡敫㔠㜭†業牣湯琠楨正†牯瀠睯敤†挠慯整†眠瑩†瀠牵†瀠汯敹瑳牥瀠睯敤灵琠〵㘭‰業牣湯桴捩Ⱬ挠汯畯潣瑡摥瀯睯敤潣瑡摥†湉汣摵湩映汩楬杮†桴慧⁰灵潴㔠洠敤瑰湡‵浭眠摩桴椠敢睴敥猠整汥†牦浡愠摮†摡慪散瑮†䍒⽃䈠楲正 匠潴敮†潷歲†祢†牰癯摩湩眠慥桴牥猠汩捩湯††敳污湡⁴†漠敶†戠捡敫†爠摯††景愠灰潲敶†畱污瑩⁹†獡†瀠牥†愠捲楨整瑣牵污搠慲楷杮愠摮†d搀物捥楴湯†景†湅楧敮牥椭挠慨杲挠浯汰瑥†木慬楺杮†桳污戠瀠楡敳慰慲整祬愠数体⁒慲整㬩牐癯摩湩湡楦楸杮漠映捡潴祲洠歡牰慰湩整猠整汥†汳摩湩眠湩潤⁷㈠†牴捡′慰敮汳摩湩楷摮睯映扡楲慣整牦浯爠汯潦浲摥猠捥楴湯慭敤漠慧癬湡穩摥猠整汥眠瑩攠潰祸†牰浩牥†景†ⴵ‷洠捩潲獮†桴捩Ⱬ映湩獩瀠楡瑮摥†楷桴†瀠汯敹瑳牥†慰湩⁴漠㈱ㄭ‶業牣湯桴捩湡慢正挠慯整楷桴愠歬摹戠捡敫ⴵ‷業牣湯桴捩牯瀠睯敤潣瑡摥†楷桴†異敲†潰祬獥整瀠睯敤甠⁰琠〵㘭‰†洠捩潲獮†桔†扡癯†牦浡獥†猠潨汵†敢映硩摥†潴†桴挠湯牣瑥⽥慭潳牮⁹眠污獬†祢洠慥獮†††景†††敳晬攭灸湡楤杮†††捳敲獷湉汣摵湩楦汬湩桴慧⁰灵潴㔠洠敤瑰湡㔠†浭†楷瑤椠戠瑥敷湥†瑳敥映慲敭愠摮愠橤捡湥⁴䍒⽃䈠楲正 瑓湯潷歲戠⁹牰癯摩湩†敷瑡敨†楳楬潣†敳污湡⁴†癯牥戠捡敫爠摯†景†灡牰癯摥†畱污瑩⁹愠瀠牥愠捲楨整瑣牵污†搠慲楷杮†湡†楤敲瑣潩†景䔠杮湩敥湩挭慨杲潣灭敬整ᜮ牐癯摩湩愠摮†映硩湩瀠敲†慰湩整†瑳敥汳摩湩眠湩潤⁷㌠†慦牢捩瑡摥†牦浯†潒汬映牯敭敳瑣潩獮洠摡景朠污慶楮敺瑓敥楷桴†灥硯⁹瀠楲敭漠㔠㜭†業牣湯琠楨正楦楮桳†慰湩整眠瑩愠†潰祬獥整瀠楡瑮†景ㄠⴲ㘱洠捩潲獮琠楨正愠摮戠捡潣瑡摥眠瑩污祫慢正牥㔠㜭洠捩潲獮琠楨正漠潰摷牥挠慯整眠瑩瀠牵瀠汯敹瑳牥†潰摷牥†灵†潴㔠ⴰ〶††業牣湯†吠敨†愠潢敶†映慲敭†桳畯摬†戠楦數琠琠敨†潣据敲整洯獡湯祲†慷汬戠⁹敭湡††漠††猠汥ⵦ硥慰摮湩††猠牣睥䤠据畬楤杮映汩楬杮琠敨朠灡甠瑰‵浭搠灥桴愠摮†‵洠眠摩桴†湩†敢睴敥猠整汥†牦浡湡摡慪散瑮删䍃 牂捩⽫匠潴敮眠牯祢瀠潲楶楤杮†眠慥桴牥†猠汩捩湯†猠慥慬瑮†漠敶慢正牥†潲漠愠灰潲敶焠慵楬祴†獡†数牡档瑩捥畴慲†牤睡湩獧†愠摮†搠物捥楴湯†漠湅楧敮牥椭档牡敧挠浯汰瑥上〴†浭†桴捩䌠浥湥⁴挠湯牣瑥映潬牯湩ㄠ㈺㐺†ㄨ挠浥湥⁴㨠†′†猠湡㨠†‴朠慲敤猠潴敮†条牧来瑡⥥㈠洰渠浯湩污†楳敺†瑳湯愠杧敲慧整†湩†慰敮獬映湩獩敨†楷桴†愠†映潬瑡湩†潣瑡†漠†敮瑡†挠浥湥⁴湩汣摵湩散敭瑮猠畬牲ⱹ戠瑵攠捸畬楤杮琠敨挠獯⁴景渠獯湩景猠整獰攠捴潣灭敬整⠮牁慥漠慰敮潮⁴潴攠捸敥⸲‰煳⥭Ƞ㔀′†浭†琠楨正†挠浥湥⁴†潣据敲整†映潬牯湩†楷桴挠湯牣瑥栠牡敤敮琠灯楰杮甠摮牥†慬敹㐠‰洠桴捩散敭瑮挠湯牣瑥㨱㨲‴ㄨ挠浥湥㩴㈠猠湡㩤㐠朠慲敤瑳湯条牧来瑡〲洠潮業慮楳敺 湡潴⁰慬敹㈱洠桴捩散敭瑮栠牡敤敮潣獮獩楴杮漠業⁸㨱′ㄨ挠浥湥⁴慨摲湥牥洠硩›′牧摡摥猠潴敮愠杧敲慧整†㘠†洠†潮業慮†楳敺 †祢†瘠汯浵ⱥ栠牡敤楮杮挠浯潰湵業數⁀′楬牴数〵杫漠散敭瑮†牯†獡†数洠湡晵捡畴敲獲†灳捥晩捩瑡潩獮桔獩椠据畬敤潣瑳漠散敭瑮猠畬牲ⱹ戠瑵攠捸畬楤杮琠敨挠獯⁴景渠獯湩景猠整獰攠捴潣灭敬整⌮㈶†洠†桴捩†散敭瑮†挠湯牣瑥†汦潯楲杮†眠瑩潣据敲整†慨摲湥牥†潴灰湩Ⱨ†湵敤氠祡牥†〵†浭琠楨正挠浥湥⁴潣据敲整ㄠ㈺㐺⠠‱散敭瑮›′慳摮›‴牧摡摥†瑳湯愠杧敲慧整†〲浭†潮業慮猠穩⥥†湡潴⁰慬敹㈱浭琠楨正挠浥湥⁴慨摲湥牥挠湯楳瑳湩景洠硩ㄠ㈺⠠‱散敭瑮栠牡敤敮業㩸㈠朠慲敤瑳湯条牧来瑡ⱥ††洶†渠浯湩污††楳敺 †戠⁹†瘠汯浵ⱥ栠牡敤楮杮挠浯潰湵業數⁀′楬牴数〵杫漠散敭瑮漠獡瀠牥洠湡晵捡畴敲灳捥晩捩瑡潩獮桔獩椠据畬敤潣瑳漠散敭瑮†汳牵祲戠瑵攠捸畬楤杮琠敨挠獯⁴景渠獯湩景猠整獰攠捴潣灭敬整輮敃敭瑮瀠慬瑳牥猠楫瑲湩㠱洠桴捩用瑰〳挠敨杩瑨 楷桴挠浥湥⁴潭瑲牡ㄠ㌺⠠‱散敭瑮›″慳摮 楦楮桳摥眠瑩汦慯楴杮挠慯⁴景渠慥⁴散敭瑮ꄮ敃敭瑮挠湯牣瑥慰敶敭瑮眠瑩敃敭瑮挠湯牣瑥㨱㨲‴ㄨ挠浥湥㩴㈠猠湡㩤㐠朠慲敤瑳湯条牧来瑡〲††浭††潮業慮†猠穩⥥††湩汣摵湩†映湩獩楨杮挠浯汰瑥挊慍楫杮†档煥敵獲†景†灡牰癯摥†慰瑴牥漠挠浥湥⁴潣据敲整映潬牯ⱳ猠整獰慬摮湩Ⱨ瀠癡浥湥獴攠捴䜮〴†浭†桴捩洠牡汢挠楨獰†汦潯楲杮†畲扢摥†湡潰楬桳摥琠牧湡汯瑩楨楦楮桳湵敤慬敹㐳洠桴捩散敭瑮挠湯牣瑥㨱㨲‴ㄨ挠浥湥⁴›′慳摮㨠㐠朠慲敤瑳湯条牧来瑡㈱㔮浭渠浯湩污猠穩⥥愠摮琠灯氠祡牥㘠浭琠楨正眠瑩桷瑩ⱥ戠慬正档捯汯瑡ⱥ朠敲ⱹ†敹汬睯漠牧敥慭扲敬挠楨獰漠楳敺牦浯ㄠ浭琠洴潮業慮楳敺氠楡湩挠浥湥⁴慭扲敬瀠睯敤業⁸㨳‱㌨挠浥湥⁴›‱慭扲敬瀠睯敤⥲戠⁹敷杩瑨†湩†牰灯牯楴湯†景†㨴‷⠠‴挠浥湥⁴洠牡汢潰摷牥†洠硩†㨠†㜠†洠牡汢†档灩⥳†戠⁹†潶畬敭椠据畬楤杮†散敭瑮†汳牵祲†瑥†潣灭敬整†›⠠牁慥†景瀠湡汥渠瑯琠硥散摥㈠〮猠浱⠩慄歲猠慨敤瀠杩敭瑮眠瑩牯楤慮祲挠浥湥&䰀杩瑨猠慨敤瀠杩敭瑮眠瑩桷瑩散敭瑮䤮敍楤浵†桳摡瀠杩敭瑮†楷桴†〵‥眠楨整†散敭瑮愠摮㔠┰漠摲湩牡⁹散敭瑮℮桗瑩散敭瑮眠瑩潨瑵愠祮瀠杩敭瑮⤮楌桧⁴桳摡楰浧湥⁴楷桴漠摲湩牡⁹散敭瑮牏楤慮祲挠浥湥⁴楷桴畯⁴湡⁹楰浧湥Ⱥ㐀‰洠琠楨正†慭扲敬†档灩映潬牯湩Ⱨ†畲扢摥†湡潰楬桳摥†潴†牧湡汯瑩楨映湩獩ⱨ†湵敤氠祡牥†ㄳ浭琠楨正挠浥湥⁴潣据敲整ㄠ㈺㐺⠠‱散敭瑮㨠㈠猠湡›‴牧摡摥猠潴敮愠杧敲慧整ㄠ⸲洵潮業慮楳敺 湡潴⁰慬敹洹桴捩楷桴眠楨整汢捡Ⱬ挠潨潣慬整牧祥礠汥潬⁷牯朠敲湥洠牡汢档灩景猠穩獥映潲洴潴㜠浭渠浯湩污猠穩慬摩椠散敭瑮洠牡汢潰摷牥洠硩㌠ㄺ⠠″散敭瑮㨠ㄠ洠牡汢潰摷牥 祢眠楥桧⁴椠瀠潲潰瑲潩漠㐠㜺†㐨†散敭瑮†慭扲敬瀠睯敤㨠†‷洠牡汢挠楨獰 戠⁹瘠汯浵椠据畬楤杮挠浥湥⁴汳牵祲攠捴潣灭敬整䄨敲景瀠湡汥渠瑯琠硥散摥㈠〮猠浱⠩慄歲猠慨敤瀠杩敭瑮眠瑩牏楤慮祲挠浥湥â㐀‰洠琠楨正†慭扲敬†档灩映潬牯湩Ⱨ†畲扢摥†湡潰楬桳摥琠牧湡汯瑩楨楦楮桳湵敤慬敹㠲洠桴捩散敭瑮挠湯牣瑥㨱㨲‴ㄨ挠浥湥⁴›′慳摮㨠㐠朠慲敤瑳湯条牧来瑡㈱㔮浭渠浯湩污猠穩⥥愠摮琠灯††慬敹†ㄠ洲†茠桴捩†眠瑩†眠楨整†戠慬正档捯汯瑡ⱥ†牧祥†敹汬睯†牯†牧敥洠牡汢挠楨獰†景猠穩獥†牦浯†洷琠ㄠ洰†渠浯湩污†楳敺†慬摩†湩挠浥湥⁴洠牡汢瀠睯 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. sqm 4483
der mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm)íMarble chips skirting (upto 30 cm height) 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 sand) : rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix :7 marble chips) by volume :Extra for laying terrazo flooring on staircase treads not exceeding 30 cm in width including cost of forming, nosing etc.qProviding and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors.v18 mm thick crazy marble stone white, black or as specified marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5 mm nominal size), including rubbing, polishing and cement slurry etc.complete .CPrecast terrazo tiles 22mm thick with graded marble chips of size upto12mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) :11.14.1Light shade using white cement.11.14.2?Medium shade using 50%white cement and 50% ordinary cement.11.14.3!Dark shade using ordinary cement.11.14.4PExtra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width.iPrecast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1:3 (1 cement : 3 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :11.16.1'Light shade pigment using white cement.11.16.2EMedium shades pigment using 50% white cement and 50% ordinary cement.11.16.3)Dark shade pigment using ordinary cement.11.16.4Chequeredterrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) :11.17.111.17.2AMedium shade pigment using 50% white cement, 50% ordinary cement.11.17.311.17.4ZChequered precast cement concrete tiles any finish, any size 22 mm thick IS:13810-1993 ISI mark in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles, 15mm thick screed bad in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.11.18.111.18.2@Medium shade pigment using 50% white cement 50% Grey cement.11.18.311.18.4Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sandand grey cement slurry, joints treated with white cement mixed with pigment to match colour of stone including rubbing and polishing complete with : (area of slabs over 0.5 sqm)11.19.1Makrana white second quality.11.19.2Raj Nagar plain.11.19.3Agaria White/Morgarh11.19.4 Katni marble11.19.5 Black Zebra.11.19.6Udaipur / Baroda green marble11.19.7Pink plain marble.11.19.8Jaisalmer YellowpMarble stone 18 Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. sqm 4269
423 9.212 摩漠敶〲洠愨敶慲敧 桴捩戠獡漠挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮†›㐠猠湡⥤氠楡湡潪湩整楷桴眠楨整挠浥湥⁴汳牵祲䀠㐠㐮欠⽧煳湩汣摵湩潰湩楴杮眠瑩桷瑩散敭瑮猠畬牲⁹摡業數楷桴瀠杩敭瑮琠慭捴桴慭扲敬猠慨敤椠据畬楤杮爠扵楢杮畣楲杮愠摮瀠汯獩楨杮攠捴污挠浯汰瑥愠猠数楣楦摥†湡愠搠物捥整戠⁹琠敨䔠杮湩敥湩䌭慨杲ਊ7䤀慴楬湡洠牡汢汦潯楲杮椠敲畱物摥搠獥杩湡慰瑴牥獮⸱㠲ㄮ̞倀潲楶楤杮愠摮氠祡湩慭档湩畣ⱴ洠物潲潰楬桳摥䤠慴楬湡䴠牡汢瑳湯㠱洠桴捩瑉污慩慍扲敬猠潴敮猠慬Ɫ敐汲瑡Ɐ删獯潳瘠牥湯ⱡ䘠物敒牯䐠牡浅数慲潤敲攠捴映潬牯湩Ⱨ椠敲畱物摥搠獥杩匨浩汰敧浯瑥楲慣ⱬ愠獢牴捡⁴瑥 湡湩瀠瑡整湲湩挠浯楢慮楴湯眠瑩瑉污慩慭扲敬猠潴敮景搠晩敦敲瑮挠汯牯ⱳ猠慨敤湡楦楮桳摥猠牵慦散琠硥畴敲攠捴Ⱞ椠楬敮牡瀠牯楴湯景琠敨戠極摬湩Ⱨ愠汬挠浯汰瑥獡瀠牥琠敨愠捲楨整瑣牵污搠慲楷杮ⱳ眠瑩ㅨ‸浭琠楨正猠潴敮猠慬慬摩漠敶〲洠愨敶慲敧 桴捩慢敳漠散敭瑮洠牯慴㨱‴ㄨ挠浥湥⁴›‴慳摮 慬摩愠摮樠楯瑮摥眠瑩桷瑩散敭瑮猠畬牲⁹ੀ⸴‴杫猯浱椠据畬楤杮瀠楯瑮湩楷桴眠楨整挠浥湥⁴汳牵祲愠浤硩摥眠瑩楰浧湥⁴潴洠瑡档琠敨洠牡汢桳摡湩汣摵湩畲扢湩Ⱨ挠牵湩湡潰楬桳湩瑥愠汬挠浯汰瑥獡猠数楣楦摥愠摮愠楤敲瑣摥戠⁹桴湅楧敮牥椭桃牡敧ܮㄱ㈮⸸防牐浥畩楨桧儠慵楬祴洠捡楨敮畣ⱴ洠物潲潰楬桳摥瑩污慩慭扲敬⠠業楮畭潣灭敲獳癩瑳敲杮桴ㄠ〸‰獰獩挠浯異獬牯⥹椠敲畱物摥猠数楣污搠獥杩湡湩爠煥極敲灳捥慩慰瑴牥湩挠浯楢慮楴湯眠瑩楤晦牥湥⁴慶楲瑥獥椠慴楬湡洠牡汢湡楦楮桳摥猠牵慦散琠硥畴敲氠湩慥潰瑲潩景琠敨戠極摬湩污潣灭敬整愠数牡档瑩捥畴慲牤睡湩獧楷桴ㄠ‸浭琠楨正猠潴敮猠慬楷桴猠潴敮猠慬慢敳猠摩灥硯⁹潣瑡湩楷桴映扩敲渠瑥愠摮琠灯猠摩灥硯⁹潣瑡湩潦湩牣慥敳猠牴湥瑧湡慬摩漠敶〲浭⠠癡牥条⥥琠楨正戠獡景挠浥湥⁴潭瑲牡ㄠ㌺⠠‱散敭瑮㨠㌠猠湡 慬摩愠摮樠楯瑮摥眠瑩桷瑩散敭瑮猠畬牲⁹⁀⸴‴杋猯浱椠据畬楤杮瀠楯瑮湩楷桴眠楨整挠浥湥⁴汳牵祲愠浤硩摥眠瑩楰浧湥⁴潴洠瑡档琠敨洠牡汢桳摡敲楳湡灥硯⁹晡整癥牥⁹畲扢湩潣瑡甠敳灥硯⁹湡敲楳湩汣摵湩畲扢湩Ⱨ挠牵湩湡潰楬桳湩瑥䤨慴楬湡洠牡汢慨潴戠牴慥整楷桴攠潰祸爠獥湩湡慭捴楨杮瀠杩敭瑮潴椠据敲獡瑩瑳敲杮桴愩汬挠浯汰瑥獡ƼȈ䜀慲楮整眠牯慧杮猠睡挠瑵⠠潰楬桳摥愠摮洠捡楨敮挠瑵 漠琠楨正敮獳†㠱浭†潦眠污氠湩湩⠠敶敮牥眠牯⥫戠捡楫杮†楦汬摥†楷桴†朠潲瑵†景†癡牥条ㄠ′浭琠楨正椠散敭瑮洠牯慴㨱″ㄨ挠浥湥㩴㌠猠湡⥤椠据畬楤杮†潰湩楴杮†楷桴†桷瑩挠浥湥⁴洠牯慴ㄠ㈺⠠‱桷瑩散敭瑮›′慭扲敬搠獵⥴眠瑩湡愠浤硩畴敲漠瀠杩敭瑮†潴†慭捴琠敨†慭扲敬†桳摡㩥†吨戠敳畣敲潴琠敨戠捡楫杮戠⁹敭湡景挠慲灭ⱳ眠楨档猠慨汬戠慰摩映牯猠灥牡瑡汥⥹䔮ᨀ䬀㴀܀ㄱ㈮⸹ᨱ牁慥漠汳扡漠敶⸰〵猠浱 ⸱㤲ㄮㄮ|䘀湩牧楡敮牧湡瑩慤歲䈠慬正搯牡敒⽤圠楨整漠煥極慶敬瑮†楷桴猠汥敤楳湧 慰瑴牥⽮牣獹慴獬漠瑯敨潣潬獲漠汧瑩整ॲㄱ㈮⸹⸱茲潃牡敳朠慲湩摥朠慲楮整氠杩瑨䈠慬正氯杩瑨删摥 景桗瑩牯攠畱癩污湥⁴楷桴猠汥敤楳湧 慰瑴牥⽮牣獹慴獬漠瑯敨潣潬獲漠汧瑩整ॲㄱ㈮⸹⸱㌳片祡倯湩⽫牂睯牯攠畱癩污湥⁴楷桴瘠牡潩獵瀠瑡整湲ݳㄱ㈮⸹ᨲ牁慥漠汳扡甠瑰⸰〵猠浱 ⸱㤲㈮ㄮ ⸱㤲㈮㈮}䌀慯獲牧楡敮牧湡瑩慤歲䈠慬正搯牡敒⽤圠楨整漠煥極慶敬瑮眠瑩敳晬搠獥杩⽮瀠瑡整湲振祲瑳污景漠桴牥挠汯牯景朠楬瑴牥 ⸱㤲㈮㌮4䜀慲⽹楐歮䈯潲湷漠煥極慶敬瑮†楷桴瘠牡潩獵瀠瑡整湲띳牐癯摩湩湡慬楹杮朠湡慳⁷畣⁴㠱洠桴捩Ⱬ洠物潲潰楬桳摥瀠敲潭汵敤眨敨敲敶敲畱物摥 湡牰潰楬桳摥洠捡楨敮挠瑵朠慲楮整猠潴敮潷歲椠汦潯楲杮漠敲畱物摥猠穩桳灡景愠灰潲敶桳摡ⱥ挠汯牯愠摮琠硥畴敲椠汦潯楲杮氠楡癯牥㈠‰浭琠楨正戠獡景挠浥湥⁴潭瑲牡ㄠ㐺⠠‱敃敭瑮›‴慳摮 湩汣摵湩牧畯楴杮琠敨樠楯瑮楷桴眠楨整挠浥湥⁴業數楷桴洠瑡档湩楰浧湥獴攠潰祸琠畯档甠獰攠捴潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩桃牡敧ܮㄱ㌮⸰ऱㄱ㌮⸰⸱笱楆敮朠慲湩摥朠慲楮整搠牡求捡⽫慤歲删摥 桗瑩牯攠畱癩污湥⁴楷桴猠汥敤楳湧 慰瑴牥⽮牣獹慴獬漠瑯敨潣潬獲漠汧瑩整ॲㄱ㌮⸰⸱लㄱ㌮⸰⸱ܳㄱ㌮⸰लㄱ㌮⸰⸲ऱㄱ㌮⸰⸲簲潃牡敳牧楡敮牧湡瑩慤歲䈠慬正搯牡敒⽤圠楨整漠煥極慶敬瑮眠瑩敳晬搠獥杩⽮瀠瑡整湲振祲瑳污景漠桴牥挠汯牯景朠楬瑴牥 ⸱〳㈮㌮ȡȈ倀潲楶楤杮愠摮氠祡湩慧杮猠睡挠瑵㌠‰浭琠楨正業牲牯†潰楬桳摥†牰洠畯摬摥†湡瀠敲†潰楬桳摥洠捡楨敮†畣⁴朠慲楮整†瑳湯漠爠煥極敲猠穩愠摮猠慨数†景†灡牰癯摥†桳摡ⱥ†潣潬牵†湡琠硥畴敲†湩映潯灴瑡ⱨ映潬牯湩湩†潲摡猠摩汰穡獡†湡楳業慬潬慣楴湯ⱳ†慬摩†癯牥†〲浭†桴捩戠獡漠挠浥湥⁴潭瑲牡†㨱‴⠠挱浥湥㩴†‴猠湡⥤†湩汣摵湩朠潲瑵湩桴潪湩獴眠瑩桷瑩散敭瑮洠硩摥眠瑩慭捴楨杮瀠杩敭瑮攠潰祸†潴捵甠獰†瑥†潣灭敬整†獡†数楤敲瑣潩†景†䔠杮湩敥湩䌭慨杲†⠠牡慥†漠†汳扡洠牯桴湡〠㔮‰煳⥭"(=⸱ㄳㄮ䘀湩朠慲湩摥†牧湡瑩搠牡䈠慬正搯牡删摥 圠楨整漠攠畱癩污湥⁴眠瑩猠汥搠獥杩⽮†慰瑴牥⽮牣獹慴獬†景漠桴牥挠汯牯景朠楬瑴牥⸱ㄳ㈮䌀慯獲朠慲湩摥†牧湡瑩氠杩瑨†求捡⽫楬桧⁴删摥 漠晦圠楨整††漠††煥極慶敬瑮††眠瑩††敳晬††搠獥杩⽮瀠瑡整湲振祲瑳污景漠桴牥挠汯牯景朠楬瑴牥⸱ㄳ㌮A䐀摥捵⁴潦潮⁴潰楬桳湩牧湡瑩汦潯楲杮⠠瑩浥渠ㄱ㈮‹…ㄱ㌮⤰'䄀摤攠瑸慲映牯瀠汯獩楨杮漠牧湡瑩潷歲Ǻ倀潲楶楤杮愠摮氠祡湩片湡瑩瑳湯汦潯楲杮椠敲畱物摥搠獥杩湡慰瑴牥獮椠楬敮牡愠敷汬愠畣癲汩湩慥潰瑲潩獮漠桴畢汩楤杮愠汬挠浯汰瑥獡瀠牥琠敨愠捲楨整瑣牵污搠慲楷杮楷桴ㄠ‸浭琠楨正猠潴敮猠慬癯牥㈠‰浭⠠癡牥条⥥琠楨正戠獡景挠浥湥⁴潭瑲牡ㄠ㐺⠠‱散敭瑮㨠㐠挠慯獲慳摮 慬摩愠摮樠楯瑮摥眠瑩散敭瑮猠畬牲⁹摡業數楷桴瀠杩敭瑮漠慭捴楨杮猠慨敤椠据畬楤杮爠扵楢杮畣楲杮愠摮瀠汯獩楨杮愠摮愠楤敲瑣摥戠⁹桴湅楧敮牥椭桃牡敧䜠慲楮整猠潴敮猠慬慄歲䈠慬正慄歲删摥桗瑩牯攠畱癩污湥ݴㄱ㌮⸳ᔱ汆浡摥䘠湩獩片湡瑩ݥㄱ㌮⸳ᔲ敌瑡敨楆楮桳倠汯獩片湡瑩瑳湯眠牯㠱浭琠楨正漠湡⁹潣潬牵椠楲敳景猠整獰歳物楴杮慤潤愠摮瀠汩慬獲氠楡湯ㄠ′浭愠敶慲敧琠楨正挠浥湥⁴潭瑲牡ㄠ㌺⠠‱散敭瑮㌺猠湡⥤愠摮樠楯瑮摥眠瑩桷瑩散敭瑮猠畬牲⁹業數楷桴瀠杩敭瑮琠慭捴桴桳摡景猠慬Ů倀潲楶楤杮†愠摮†映硩湩†〱ㅸ砰⸷〵†挠†片湡瑩瑳湯汢捯慨摮挠瑵愠摮档獩汥搠敲獳摥漠潴Ɒ映牯瀠癡湩湩映潬牯ⱳ搠慲湩瑥氠楡癯牥㈠洰桴捩慢敳†洠牯慴†㨱‴†ㄨ散敭瑮㐺†猠湡⥤†眠瑩†潪湩獴ㄠ洰眠摩映汩敬眠瑩猠浡洠牯慴洠硩摥†楷桴洠瑡档湩瀠杩敭瑮††湩汣摵湩爠汵摥†潰湩楴杮†瑥挠浯汰瑥獡瀠牥搠物捥楴湯漠湥楧敮牥椭档牡敧㨮潋慴†瑳湯猠慬映潬牯湩漠敶㈠‰洠⠠癡牥条⥥琠楨正†慢敳氠楡癯牥愠摮樠楯瑮摥眠瑩牧祥挠浥湥⁴汳牵祲洠硩摥眠瑩楰浧湥⁴潴洠瑡档琠敨猠慨敤漠桴汳扡椠据畬楤杮爠扵楢杮愠摮瀠汯獩楨杮挠浯汰瑥楷桴†慢敳†景†散敭瑮†潭瑲牡†‱㨠†‴⠠‱挠浥湥⁴㨠†‴慳摮 㔲洠琠楨正⠮牁慥漠猠慬潴戠癯牥〠㈮‵煳⥭`䐀摥捵楴湯映牯甠楳杮㈠‰洠桴捩汳扡椠獮整摡漠㔲洠桴捩汳扡漠潫慴猠潴敮椠瑩浥渠ㄱ㌮ℵ潋慴猠潴敮猠慬獢椠楲敳獲漠瑳灥ⱳ猠楫瑲湩Ⱨ†慤潤愠摮瀠汩慬獲氠楡湯ㄠ′浭⠠癡牥条⥥琠楨正挠浥湥⁴潭瑲牡†㨱″⠠‱挠浥湥⁴㌠†潣牡敳†慳摮 愠摮†潪湩整楷桴†牧祥†散敭瑮†汳牵祲†業數眠瑩瀠杩敭瑮†潴洠瑡档†桴猠慨敤†景†桴猠慬獢椠据畬楤杮†畲扢湩湡潰楬桳湩潣灭敬整ܮㄱ㌮⸸ั〱ㄭ′浭琠楨正⸱㠳㈮Ĥ䬀瑯猠潴敮†汳扡†愨敲氠獥琠慨〠㔮†煳⥭†潲杵档獩汥摥搠敲獳摥愠敶慲敧㐠‰浭琠楨正映潬牯湩潦慰歲湩愠摮†灯湥†牡慥†景†桴捩湫獥漠敶㈠‰洠愨敶慲敧 琠楨正†慢敳†慬摩†癯牥†湡樠楯瑮摥†楷桴朠敲⁹散敭瑮猠畬牲⁹潣灭敬整眠瑩慢敳漠散敭瑮洠牯慴㨱‴ㄨ䌠浥湥⁴›‴慓摮牐癯摩湩攠杤洠畯摬湩琠ㄠ洸琠楨正†慭扲敬猠潴敮††潣湵整獲†嘠湡瑩敩ⱳ††楷摮睯††楳汬†攠捴湩汣摵湩慭档湩潰楬桳湩潴攠杤潴朠癩楨桧朠潬獳映湩獩瑥挠浯汰瑥獡瀠牥搠獥杩灡牰癯摥戠⁹湅楧敮牥椭桃牡敧ܮㄱ㐮⸰慍扲敬眠牯ݫㄱ㐮⸰ല片湡瑩潷歲퐮硅牴映牯†楦楸杮†慭扲敬†术慲楮整†瑳湯漠敶愠摮愠潢敶†挠牯敲灳湯楤杮†戠獡捩†椠整Ɑ†椠†慦楣†湡牤灯漠眠摩桴†灵潴†㔱‰洠眠瑩攠潰祸†敲楳慢敳摡敨楳敶椠据畬楤杮挠敬湡湩瑥挠浯汰瑥ņ䔀瑸慲†潦瀠潲楶楤杮†灯湥湩漠爠煥極敲猠穩愠摮猠慨数†潦眠獡戠獡湩⽳†楫捴敨猠湩椠欠瑩档湥瀠慬晴牯Ɑ†慶楮祴†潣湵整獲†湡猠浩汩牡†潬慣楴湯†湩洠牡汢⽥片湡瑩⽥瑳湯†潷歲†椠据畬楤杮†渠捥獥慳祲栠汯獥†映牯†瀠汩慬†慴獰†攠捴†湩汣摵湩†潭汵楤杮畲扢湩湡潰楬桳湩景挠瑵攠杤獥攠捴潣灭敬整茮楍牲牯††瀠汯獩楨杮††漠††慭扲敬††眠牯⽫片湡瑩潷歲猯潴敮†潷歲†桷牥癥牥†敲畱物摥†潴†楧敶†楨桧朠潬獳映湩獩
complete.Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1cement : 5 sand) with joints finished flush.11.44.111.44.211.44.3Grey lime stone11.44.4 Kota stoneâ40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5(1cement: 5 sand) including pointing with cement mortar 1:2 (1cement:2 sand) with an admixture of pigment to match the shade of stone.11.45.111.45.2ß40 mm thick machine rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 sand) mixed with G pigment to match the shade of stone and pointing with same mortar11.46.111.46.2PExtra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.cExtra for Kota stone/ sand stone in treads of steps and risers using single length upto 1.05 metre.aProviding and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete.úProviding and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete.Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete.Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete.^Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete.Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.mDeduct for not using 20mm thick cement mortar 1:4 (1 cement: 4 sand) bedding in laying of floor tiles.ÂFixing glazed/ Ceramic/Rectified/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness./Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.ÔProviding and fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:nProviding and laying 500x500x40mm thick Turf paver on 150mm thick sub grade of compacted bed of 20mm nominal size stone aggregate and base course with 50mm thick sand and filling joints with sand including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. %Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and colour using acid and/ or alkali resisting mortar bedding and joints filled with acid and/ or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge.11.60.1}In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 sand)Acid and alkali resistant tile. 11.60.2}In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 sand).Acid and alkali resistant tile. "8 mm thick.stones Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete.11.61.1"Marble tiles (polished) Raj Nagar.11.61.2!Granite tile of any colour /shadeProviding and fixing cramps of required size and shape in RCC/ CC /Stone/ Brick masonry backing with cement mortar 1:2 ( 1 cement :2 sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 11.62.1Gunmetal cramps.11.62.2Stainless steel cramps.Providing and fixing expansion hold fasteners of wedge expansion type on C.C. / R.C.C./ Brick masonry surface backing including = drilling necessary holes and the cost of bolt etc complete.11.63.1 Fastener with threaded dia 6 mm.11.63.2"Fastener with threaded dia 10 mm.11.63.3"Fastener with threaded dia 12 mm.»Providing and fixing stone slab table rubbed on both faces edges rounded and polished of size as required and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.11.64.1White Agaria Marble Stone.11.64.2 Granite Stone of approved shade.aProviding and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer- in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.11.65.1"300 mm Finished Floor Height (FFH)11.65.2#450 mm Finished Floor Height (FFH).<Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with gr 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. sqm 4350
ey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge.ðProviding Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. fwith 5 year defect liability period (This item is to be used only for operation theaters in hospitals)11.67.1 1 mm thick11.67.2 2 mm thick11.67.3 3 mm thick"Providing and fixing acoustic PVC (Poly Vinyl Flooring) EN (European Standard) over fiberglass mat PVC foam backing (EN 14904), total thickness is 3.25mm (EN 428/EN 427), wear layer is 0.85 mm thick (EN 429), anti-bacterial and anti-fungus surface treatment , chemical resistance test qualified (EN-423)-high resistance, thermal and underfloor heating test qualified (EN12524) - all vinyl sheets must be linked crosswise with a continuous copper strip and finally connected to earth for grounding electrostatic electrical charges. Suitable and slip resistant. Recommended to use in area like Lecturer room, Conference room, Kids area, School, colleges, Residential and all commercial official scope etc. ¯Providing and fixing 2 mm thick heterogeneous PVC (poly vinyl flooring) EN (European Standard) with wear layer is 0.55mm thick of PVC, total weight is 2300 g/m2 approx. PUR (polyurethane reinforced), residual indentation approx.0.05 mm, castor wheel test qualified, dimensional stability d"0.10%, static electrical charge .The floor finish should termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto100mm. Recommended to use in area like Patient rooms , Doctor room Lecturer room, Kids area, School, Colleges, Residential and all commercial official scope etc.Providing and fixing 8mm and above thick laminated (wooden flooring) of AC4 and above grade product of approved made out of core high density fibre board (HDF), surface layer shall be high preasure laminated treated for abrasion, scratch, moisture protection, flame protection U.V resistant, layer of acrylic resin, aluminium oxide or similer layer having above properties, backing under layer on min 2 mm thickness shall provide as sound absorbent and moisture protection layer, The seamless impregenated decorative layer of specified size, design, colour and pettern, all bonded together under high temperature and pressure with eco-friendly. The material shall be applicable warranty formaldehyde free, eco- friendly and fully recyclable (eco-freindly) and matching shed and excluding quantity of skirting and profile.àBrick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, 1:6 (1 cement : 6 sand) including filling the joints with same mortar, with common burntclay non modular bricks11.71.1 100 mm thick11.71.2 200mm thickCProviding and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colour and pattern over 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of Engineer-in-Charge.11.72.1*80 mm thick C.C. paver block of M-35 grade11.72.2*60 mm thick C.C. paver block of M-35 grade11.72.3*60 mm thick C.C. paver block of M-30 gradeProviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- Charge). 5Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side(top & bottom), including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-Charge.ßProviding and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite of approved shade, colour and texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand) Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1>Granite Door frame for 100mm thick wall Thickness.11.75.2>Granite Door frame for 200mm thick wall Thickness.ÕProviding and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete11.76.1:Plain ivory light shade : Size 600X600mm thickness 9-10mm 11.76.2:Dark shade (terracotta) : Size 600X600mm thickness 9-10mm ÔProviding and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete @=11. 77.111. 77.28Dark shade (terracotta):Size 600X600mm thickness 9-10mm òProviding and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& sha des, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 78.1-In light shade glossy/ rustic /stain finished 11. 78.1.1!Size 600X600 mm thickness 9-10 mm 11. 78.1.2 Size 800X800mm thickness 11-12mm 11. 78.1.3"Size 800X1200 mm thickness 11-12mm11. 78.2,In dark shade glossy/ rustic /stain finished 11. 78.2.1%(a) Size 600X600 mm thickness 9-10 mm 11. 78.2.2$(b) Size 800X800mm thickness 11-12mm 11. 78.2.3&(c) Size 800X1200 mm thickness 11-12mmîProviding and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete/@1=11. 79.1 11. 79.1.1 11. 79.1.2 11. 79.1.311. 79.2*In dark shade glossy/rustic/stain finished 11. 79.2.1 11. 79.2.2 11. 79.2.3°Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete11. 80.1<In light colour and shades as ivory, beige blanco, grey etc. 11. 80.1.1%(a) Size 300X300 mm thickness 9-10 mm 11. 80.1.2#(b) Size 600X600mm thickness 9-10mm 11. 80.1.3¶(c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.)11. 80.2In dark colour and shade etc. 11. 80.2.1 11. 80.2.2 11. 80.2.3¿(c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.)ÈProviding and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting, riser laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. completeó@õ=11. 81.1 11. 81.1.1 11. 81.1.211. 81.2In dark colour and shades etc. 11. 81.2.1 11. 81.2.2gProviding and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality including grouting the joints with white cement and matching pigments etc. completeë@í=11. 82.1cFor floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 11. 82.1.2!Size 800X800mm thickness 9-10 mm 11. 82.1.3"Size 800X1600 mm thickness 9-10 mm 11. 82.1.4$Size 1000*1000 mm thickness 9-10 mm 11.82.1.5#Size 600*1200 mm thickness 9-10 mm11.82.16#Size 800*1200 mm thickness 9-10 mm 11.82.1.7$Size 1200*1200 mm thickness 9-10 mm 11.82.1.8$Size 1200*1800 mm thickness 9-10 mm 11.82.1.9$Size 1200*2400 mm thickness 9-10 mm11. 82.2For wall stain / rustic finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e.within 6 hours, " Size 300X600 mm thickness 9-10 mmProviding and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. completeÔ@Ö=11. 83.1TFor skirting, risers etc.glossy/rustic/stain/matt finished in all colours and shades 11. 83.1.1 11. 83.1.2 11. 83.1.3"Size 600X1200 mm thickness 11-12mm 11. 83.1.4×Granite work gang saw cut (polished machine cut) of thickness 12 mm for wall lining, skirting, risers of steps and dado (veneer work), back filling with a grout of average 12 mm thick in cement mortar 1:3 (1 Cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the beaching by means of cramps, which shall be paid for separately).11. 84.1Area of tiles not less 0.18 sqm 11. 84.1.1eFine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 84.1.2hCourse granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 84.1.3%Gray/Pink/Brown with various patterns½Providing and laying gang saw cut 12mm thick, mirror polished pre moulded (wherever required) and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in flooring laid over 20mm thick base of cemnt mortar 1:4(1cement:4sand) including grouting the joints with white cement mixed with matching pigments, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.11. 85.1 11. 85.1.1sFine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 85.1.2wCoarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 85.1.311. 86dProviding and fixing artificial synthetic green long and fine yarns grass, UV/water resistant with SBR latex backing eco-friendly durable high density 100 % PP ( Poly Poplin ) anti UV fiber.denier 12000 dtex, stich rate 18 stiches per 10cm, stich density 16800 stiches/m2, tufted weight 1830g/sqm approx.11. 86.1FRoll size will be 25.00m X 2.00m (25mm thick)- weight 150kg- per roll.11. 86.2FRoll size will be 25.00m X 2.00m (40mm thick)- weight 180kg- per roll.Providing and fixing laminated (engineered wooden flooring) of suitable thickness 10-14 mm of suitable grade category product of approved made out of core high density fibre board (HDF) &other component it treated for abrasion ,scratch ,moisture protection, flame protection,U.V resistant. backing with eco- friendly resins specified by the sqm 4150
nd above with total mass of 4100g/m2approx and with polyester fleece primary backing with standard dimensional stability with impact sound / noise reduction and recommended for high traffic acoustical area.Providing and fixing spc (stone plastic composite) virgin pvc water resistant proof vinyl flooring with a thickness between 4 to 8mmuv coated layer with a wear layer of 0.3 to 0.80mm with a SPC core layer of 2.00 to 5.00 mm with a SOP of heat resistant, voc free, easy to cut, anti microbial protection in the form of tiles, planks helpful in environmental of profection health.*Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone tile flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with white cement mix with matching pigment etc. complete as per direction of Engineer-in-Charge.11. 91.1 300x300mm11. 91.2 400x400mm11. 91.3 600x600mmJProviding and laying pre mirror polished/ pre polished fine grain machine cut sand stone slab flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size of area more then .50 sqm and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with cement mix matching pigment etc. complete as per direction of Engineer -in-Charge. Supply and application of vinyl flooring of 4.5 mm thick with 1.5 mm wear layer comes in oll size of (1.8mx15m) available in different color options. PVC vinyl cushion indoor flooring comes with I indentation of less than 0.5 and also have good abrasion and impact resistance. It also have better shock absorption property of more than 35 and good ball rebounce property of about 98%.\Providing corrugated G.S. Sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:1.00mm thick with zinc coating not less than 275gm/m²:0.80mm thick with zinc coating not less than 275gm/m²<0.63 mm thick with zinc coating not less than 275gm/m²Straight cutting in G.S. sheet of any thickness roofing for making opening of area exceeding 40 sq. decimetre for chimney stacks, sky light etc.Extra for circular cutting in C.G.S. sheet of any thickness roofing for making opening of area exceeding 40 square decimetre :ÑProviding ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.:0.63mm thick with zinc coating not less than 275gm/m²îProviding valleys of 90cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350gm/m² 4Providing and Fixing of 40 cm over all width plain, G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts,G.I.limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1cement : 3 sand).1.00mm thick with zinc coating not less than 275gm/m²æProviding and fixing 15 cm wide 45 cm over all semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete.åProviding reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia.G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc..ðExtra for circular cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated/ semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter.LExtra for providing and fixing wind ties of 40x 6 mm flat iron section.ðProviding and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.%Corrugated serrated adjustable ridgesPlain wing adjustable ridgesClose fitting adjustable ridgesUnserrated adjustable hipsYProviding and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete:12.13.1Corrugated apron pieces12.13.2Eave's filler pieces12.13.3North light curves12.13.4ventilator curves12.13.5 Barge boards12.13.6 Ridge finialspair12.13.7Special north light curves12.13.8S type louversProviding flat iron brackets 50x3mm size with necessary bolts, nuts washers etc. for fixing G.S. sheets gutters with purlins.KProviding and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. `Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self- tapping screws complete : 12.16.1Ridges plain (500 - 600mm).12.16.2 Flashings/ Aprons.( Upto 600 mm)12.16.3North light curves.12.16.4Barge board (Upto 300 mm)12.16.5 Crimp curve12.16.6 牥㘨〰洠癯牥愠汬朠物桴﬩牐癯摩湩†…†楦楸杮†唠⁖†瑳扡汩獩摥映扩牥汧獡†爠楥普牯散†瀠慬瑳捩††桳敥⁴潲景湩†灵†琠†湡⁹†楰捴ⱨ†椠据畬楤杮映硩湩眠瑩瀠汯浹牥†潣瑡摥†䨧‧漠✠❌栠潯獫戠汯獴†…渠瑵㠠浭†楤†⹇⁉汰楡⽮楢畴敭†慷桳牥†潣灭敬整†戠瑵攠捸畬楤杮†桴挠獯⁴漠瀠牵楬獮爠晡整獲牴獵敳†攠捴†吠敨††桳敥獴††桳污†戠慭畮慦瑣牵摥†畯⁴漠㈠〴‰吠塅†慰敮潲楶獧†湩潣灲牯瑡湩洠湩浩浵†⸰┳甠瑬慲瘭潩敬⁴猠慴楢楬敳椠爠獥湩†祳瑳浥甠摮牥愠灰潲楸慭整祬㈠〴‰獰湡潨⁴畣敲†吠敨⁹†桳污†敢†漠†湵晩牯楰浧湥慴楴湯愠摮琠楨正敮獳眠瑩潨瑵愠物瀠捯敫獴愠摮猠慨汬挠湯潦浲琠卉ㄠ㈹愠摮†䤠⁓†㈱㘸⸶桔†桳敥獴†猠慨汬†戠灯煡敵††牯††牴湡汳捵湥ⱴ††汣慥†漠楰浧湥整Ɽ†琠硥畴敲†牯†猠潭瑯†獡猠数楣楦摥ܮ㈱ㄮ⸷失洲桴捩潣牲杵瑡摥⠠⸲∵漠⸴∲漠∶ 漠猠整⵰潤湷†㈨漢㌠漢㘠⤢†獡猠数楣楦摥ܮ㈱ㄮ⸷༲洲桴捩汦瑡㈮牐癯摩湩愠摮†䘠硩湩漠†歳⁹氠杩瑨潣獮獩楴杮†漠†畍瑬†散汬琯杩瑨†挠汥潐祬慣扲湯瑡††慐敮††祓瑳浥††漠灡牰癯摥††挠汯畯Ⱳ††ㄠ‶††浭††琠楨正⠠業楮畭⥭†慨楶杮†湵晩牯椠挠汯牯眠瑩†愠†椠瑮来慲吠杩瑨䌭汥†挠牯潣獮牴捵整渠瑯†潴†硥散摥†洴硭洴湩†挠潲獳†ǝ 猠捥楴湯椠癮汯敶畳档愠†潢瑬†畮獴†愠摮†猠牣睥†瑥†愠摮氠扡畯潦畣瑴湩敢摮湩潴爠煥極敲牰景汩ⱥ渠捥獥慳祲猠慣晦汯楤杮潨獩楴杮椠瀠獯瑩潩攠捴映牯瀠潲数挠浯汰瑥潩景†琠敨†眠牯†瑥†挠浯汰瑥†獡†瀠牥猠数楣楦慣楴湯†牤睡湩獧†湡搠物捥楴湯漠†䔠杮湩敥†椠†挠慨杲††楆楮桳摥猠牵慦散愠敲景爠潯楦杮映硩摥漠敶瑳敥畴畢慬瑳畲瑣牵桳污敢洠慥畳敲潦慰浹湥䴠⁓慴畢慬牦浡潷歲猠慨汬戠敭獡牵摥猠灥牡瑡汥⁹潦慰浹湥⸲㠱ㄮ 洰桴捩ݫ㈱ㄮ⸸ਲ㘱浭琠楨正Ɣ倀潲楶楤杮猠湡瑳湯汳扡㐠‰潴㔠‰浭琠楨正†潦爠潯楦杮†湡氠祡湩琠敨椠散敭瑮†潭瑲牡†‱㨠†‴⠠‱挠浥湥⁴㨠†‴慳摮 漠敶眠潯敤欠牡楲獥†牯†⹒⹃⹃戠瑡整獮†漠†瑳畲瑣牵污†猠整汥†猠捥楴湯䬨牡楲獥†牯†慢瑴湥漠猠牴捵畴慲猠整汥猠捥楴湯††潴††戠††慰摩††猠灥牡瑡汥⥹椠据畬楤杮†潰湩楴杮†桴挠楥楬杮†潪湩獴眠瑩散敭瑮洠牯慴㨱″†††ㄨ挠浥湥⁴›″慳摮⤠挠浯汰瑥ܺ㈱ㄮ⸹ጱ敒慳摮猠潴敮猠慬ݢ㈱ㄮ⸹ᜲ桗瑩慳摮猠潴敮猠慬䌺慐湩楴杮†潴⁰†景†爠潯獦†眠瑩†敲楳畤污琠灹瀠瑥潲敬浵†楢畴敭漠朠慲敤†䝖ㄠ‰景愠灰潲敶畱污瑩⁹⁀㜱杫瀠牥ㄠ‰煳椠灭敲湧瑡摥†楷桴†挠慯⁴漠猠湡瑡††〶††畣†瀠牥††〱煳†椠据畬楤杮挠敬湡湩桴汳扡猠牵慦散眠瑩牢獵敨湡楦慮汬⁹楷桴愠瀠敩散漠汣瑯楬桧汴⁹潳歡摥椠敫潲敳敮漠汩挠浯汰瑥ᔺ牐癯摩湩愠摮†灡汰楹杮†睴挠慯獴†景䠠杩䄠扬摥瀠楡瑮†慨楶杮†業楮畭潓慬敒汦捥楴敶䤠摮硥⠠剓⥉ㄠ㠰⠠楷桴猠汯牡†††敲汦捥慴据††愠摮†††桴牥慭浥瑩慴据†整瑳摥†愠†数†十䵔 †⁃㔱㤴愠摮䄠呓⁍⁃㌱ㄷ爠獥数瑣癩汥⥹佖⁃敬獳琠慨〱挠⽣浧桔潣瑡湩桴捩湫獥†湡†桴†敭桴摯汯杯⁹†景愠灰楬慣楴湯†猠慨汬†戠†瑳楲瑣祬†愠†数慭畮慦瑣牵牥猧†猠数楣楦慣楴湯†湡†獡愠灰潲敶†戠⁹†攠杮湩敥†䤠†挠慨杲匠牵慦散†牰灥牡瑡潩椠据畬敤挠敬湡湩楷桴†敭慴眠物戠畲桳†潴†敲潭敶†污畤瑳映湵畧攠捴Ⱞ†湡眠獡楨杮†楷桴眠瑡牥†愠汬†挠浯汰瑥†吠敨†挠湯牴捡潴桳污††朠癩††朠慵慲瑮敥†††潦††琠敨瀠牥潦浲湡散†漠†剓⁉†湡†污潳†琠敨搠牵扡汩瑩⁹漠挠慯楴杮愠汬†潣灭敬整†獡瀠牥搠物捥楴湯漠湅楧敮牥椭档牡敧씮牐癯摩湩愠摮†楦楸杮†效瑡†敒楳瑳湡⁴敔牲捡楔敬㌨〰洠⁸〳‰浭砠㈠‰浭 楷桴匠䥒⠠潳慬敲牦捡楴敶椠摮硥 ‾㠷潳慬敲汦捥楴湯㸠⸰〷愠摮椠楮楴污攠業瑴湡散†㸠⸰㔷†漠†慷整灲潲景†愠摮猠潬数猠牵慦散†景†整牲捡ⱥ†慬摩†湯†〲洠琠楨正†散敭瑮†慳摮†潭瑲牡†湩†桴慲楴漠ㄠ㐺†ㄨ†散敭瑮†›㐠†慳摮 愠摮朠潲瑵湩琠敨†潪湩獴†楷桴†業⁸漠眠楨整挠浥湥⁴湡慭扲敬瀠睯敤湩爠瑡潩漠㨱ⰱ†湩汣摵湩爠扵楢杮†湡瀠汯獩楨杮漠謠桴猠牵慦散†灵潴†″挠瑵挠浯汰瑥ⱥ椠据畬楤杮†牰癯摩湩猠楫瑲湩甠瑰ㄠ〵洠栠楥桧⁴愠潬杮琠敨†慰慲数⁴眠污獬†湩琠敨猠浡慭湮牥欮牐癯摩湩湡慬楹杮瀠敲獳摥挠慬⁹楴敬愨†数†灡牰癯摥††瀠瑡整湲†㈠‰†浭渠浯湩污†琠楨正敮獳†愠摮†漠†灡牰癯摥猠穩⥥†漠†潲景†潪湩整†楷桴†挠浥湥⁴潭瑲牡ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⥤洠硩摥眠瑩†㈠‥†椠瑮来慲†眠瑡牥††牰潯楦杮挠浯潰湵氠楡漠敶愠†敢漠㈠‰洠桴捩散敭瑮洠牯慴㨱‴ㄨ挠浥湥⁴›‴慳摮 湡楦楮桳摥渠慥⁴潣灭敬整牐癯摩湩愠摮†楦楸杮†湯†潲景†牰獥敳汣祡†琠汩†䴨湡慧潬敲†琠汩⥥†㈠‰†浭渠浯湩污†琠楨正敮獳†愠摮†漠†灡牰癯摥猠穩愠摮†獡†数愠灰潲敶瀠瑡整湲†湯猠整汥††牦浡†眠牯†挠浯汰瑥†⠠瑳敥牦浡潷歲琠敢瀠楡敳慰慲整祬줩牐癯摩湩愠摮†慬楹杮†湯†潲景†牰獥敳汣祡†琠汩†楲杤†䴨湡慧潬敲†琠汩⥥†漠〲浭†桴捩湫獥漠愠灰潲敶瀠瑡整湲漠猠整汥†牦浡眠牯挠浯汰瑥⠠瑳敥牦浡潷歲琠敢瀠楡敳慰慲整祬牐癯摩湩朠汯㜠砵㔷†浭†湩†散敭瑮挠湯牣瑥㨱㨲‴ㄨ挠浥湥⁴›′†慳摮㨠㐠猠潴敮†愠杧敲慧整†ㄠ洰†湡†潤湷朠慲敤 †椠据畬楤杮††††楦楮桳湩†眠瑩散敭瑮洠牯慴㨱″ㄨ挠浥湥⁴›″慳摮 獡瀠牥猠慴摮牡敤楳湧㨠䤠†㔷㝸洵敤灥挠慨敳䴀歡湩桫牵慲㔴㑸‵浣⠠畳歮愠敲⥡眠瑩癡牥条業楮畭桴捩湫獥景㔠挠散敭瑮挠湯牣瑥㨱㨲‴ㄨ挠浥湥⁴›′猠湡㨠†‴朠慲敤猠潴敮†Ɩ愀杧敲慧整†景㈠‰†浭†渠浯湩污†猠穩⥥†漠敶†⹐⹖⹃猠敨瑥††洱ㅸ硭〴洰捩潲Ɱ††楦楮桳摥眠瑩†㈱浭†挠浥湥⁴†汰獡整†㨱″†ㄨ挠浥湥⁴㨠†″猠湡⥤†湡愠†潣瑡†景†敮瑡挠浥湥⁴潲湵楤杮琠敨攠杤湡慭楫杮愠摮映湩獩楨杮琠敨漠瑵敬⁴潣灭敬整猠獡琠敲散癩慲湩眠瑡牥 灳汩慬敧眠瑡牥漠潲景†湩†猠湵愠敲愠摮†潣灭敬整祬爠楡畯⁴湩愠渠慥数晲捥⁴瑳慲湩洠瑥牥洠瑯潩湩潴爠楡慷整楰数漮牐癯摩湩愠摮†楦楸杮†⹍⹓†潨摬牥†慢⁴汣浡獰†景†灡牰癯摥†敤楳湧†潴†⹃⹉†牏匠䌮䤮爠楡眠瑡牥†楰数攠扭摥敤椠湡湩汣摵湩散敭瑮挠湯牣瑥戠潬正〱ㅸ砰〱浣†漠††䌠浥湥⁴†潃据敲整ㄠ㈺㐺†業⁸⠠‱挠浥湥⁴㨠†′猠湡㨠†‴牧摡摥††瑳湯†愠杧敲慧整††〲††浭渠浯湩污†猠穩⥥†愠摮†挠獯⁴†景††挠瑵楴杮栠汯獥愠摮洠歡湩潧摯琠敨眠污獬攠捴ܮ㈱㈮⸸༱〱‰浭搠慩敭整ݲ㈱㈮⸸༲㔱‰浭搠慩敭整䅲牐癯摩湩湡楦楸杮䤠䥓洠牡敫慳摮挠獡⁴物湯爠楡慷整楰数܊㈱㈮⸹⨱〱‰洠搠慩†業楮畭眠污琠楨正敮獳㔠浭⸲㤲㈮*〵†浭†楤洠湩浩浵†慷汬†桴捩湫獥洵呭牐癯摩湩氠慥挠畡歬摥†潪湩獴†潴†慳摮挠獡⁴物湯爠楡慷整楰数湡楦瑴湩獧㨠⸲〳ㄮ〰洠楤倠灩ݥ㈱㌮⸰ဲ㔱‰浭搠慩楐数ì倀潲楶楤杮楦楸杮愠摮攠扭摥楤杮猠湡慣瑳†物湯†捡散獳牯敩映牯†慲湩†慷整楰数湩琠敨洠獡湯祲猠牵潲湵敤楷桴ㄠ′洠琠楨正†散敭瑮†潭瑲牡†景†桴慳敭†業ⱸ†獡†桴瑡†景†慭潳牮⁹⠠敬摡挠畡歬湩楷汬戠慰摩映牯猠灥牡瑡汥⥹㨠܊㈱㌮⸱ᔱ慓摮挠獡⁴物湯戠湥ऺ㈱㌮⸱⸱ऱ㈱㌮⸱⸱ܲ㈱㌮⸱ᰲ慓摮挠獡⁴物湯瀠慬湩猠潨獥㨠 ⸲ㄳ㈮ㄮ ⸲ㄳ㈮㈮ě倀潲楶楤杮†愠摮†映硩湩†湯†眠污†慦散删杩摩唠灮慬瑳捩獩摥爠杩摩倠䍖⠠灵捶 楓杮敬††潳正瑥摥††慲湩††慷整†瀠灩獥挠湯潦浲湩琠†卉†›ㄠ㔳㈹†祔数†⁁湩汣摵湩†樠楯瑮湩†眠瑩†猠慥†爠湩潣普牯業杮†潴††卉†›㔠㠳′氠慥楶杮†〱洠慧⁰潦桴牥慭硥慰獮潩:㜀‵†洠†搠慩敭整†⠠業楮畭†眠污桴捩湫獥⸱洸⥭㘊ㄱ‰†浭†搠慩敭整†洨湩浩浵†眠污桴捩湫獥⸲洲⥭Ō倀潲楶楤杮†愠摮†映硩湩†湯†眠污†慦散唠灮慬瑳捩獩摥††ⴠ††唠噐⁃††潭汵敤楦瑴湩獧 愠捣獥潳楲獥†潦唠灮慬瑳捩獩摥删杩摩†††噐⁃††爠楡††眠瑡牥†††楰数潣普牯業杮†潴†卉†›ㄠ㔳㈹††祔数†⁁湩汣摵湩†樠楯瑮湩†眠瑩†猠慥†爠湩潣普牯業杮†潴†卉†›㔠㠳′氠慥楶杮†〱洠慧⁰潦桴牥慭硥慰獮潩Ⰺ㔷†洠†洨湩浩浵†眠污†桴捩湫獥⸱洸⥭-〱†洠†洨湩浩浵†眠污†桴捩湫獥⸲洲⥭6㜀砵㔷㝸‵††浭††⠠業楮畭††慷汬琠楨正敮獳ㄠ㠮浭㌩ㄱ砰ㄱ砰ㄱ‰†浭†⠠業楮畭†慷汬琠楨正敮獳㈠㈮浭㨩ㄱ‰††浭††戠湥††洨湩浩浵††眠污桴捩湫獥⸲洲⥭*㜀‵浭匠潨洨湩浩浵眠污桴捩湫獥⸱洸⥭㨊ㄱ‰††浭††匠潨††洨湩浩浵††眠污桴捩湫獥⸲洲⥭Ŷ倀潲楶楤杮†湡映硩湩甠灮慬瑳捩獩摥†噐⁃楰数挠楬獰漠灡牰癯摥搠獥杩潴甠灮慬瑳捩獩摥†倠䍖†慲湩†慷整瀠灩獥戠⁹敭湡景㔠砰〵㕸‰浭栠牡潷摯瀠畬獧猠牣睥摥†楷桴†⹍⹓†捳敲獷†景爠煥極敲†氠湥瑧ⱨ††湩汣摵湩†挠瑵楴杮戠楲正†眠牯†湡†楦楸杮†椠†散敭瑮洠牯慴㨱‴ㄨ挠浥湥⁴›‴潣牡敳猠湡⥤愠摮††慭楫杮††潧摯††桴†眠污†攠捴潣灭敬整ਮꈊ牐癯摩湩†湡†楦楸杮†琠†桴†湩敬 sqm 3950
424 9.213 mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams.ØProviding and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.zProviding and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand)Providing and fixing of self-supported mechanically seamed roofing system, made of high quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A 792 M of base metal thickness from 0.8 mm to 1.6mm (tolerance ± 0.02mm). High grade steel sheet should have 55% aluminum and 45% zinc coating by hot-dip process of minimum 25 micron The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers/clamps for installation of lighting /fixtures /utility/ duct as per requirement and ventilators, skylight can also be provided at crown/ridge by making cuts into the panels which is to be paid separately. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise. 12.38.18Base metal thickness 0.8mm up to span 15 meter12.38.26Base metal thickness 0.9mm , up to span 18 meter12.38.36Base metal thickness 1.0 mm, up to span 21 meter12.38.46Base metal thickness 1.1 mm, up to span 23 meter12.38.53Base metal thickness 1.2mm, up to span 25meter12.38.66Base metal thickness 1.3 mm, up to span 27 meter12.38.73Base metal thickness 1.4mm, up to span 29meter12.38.86Base metal thickness 1.5 mm, up to span 31 meter12.38.96Base metal thickness 1.6 mm, up to span 33 meter12.38.10´Providing and fixing galvalume 1.0 mm thick clamps/hangers of size 75X140mm with saddle of 50mm dia, riveted at one side and nut and bolt at other side, to self-supported roofing system by mechanical seaming to suspend light fixture/cable stay/false ceiling/duct etc., at their location which should be planned earlier by engineer-in-charge. Clamps shall be fixed during seaming of panels.12.38.11ÖProviding and fixing advanced type hurricane turbo ventilator to self- supporting roof having neck dia 600mm made of aluminum having 24 nos vertical vanes made of aluminum sheet. Ventilator should be fixed on 1 to 2mm thick G.I. ring which shall be fixed on 2mm thick polycarbonate sheet. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates i/c of all material, labour fittings screw, rings, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof.12.38.12pProviding and fixing of 2mm thick polycarbonate sheet to self-supported roofing system. The sheet shall have tensile strength and elongation as per ASTM D 638, refractive index as per ASTM D 592, light transmission as per ASTM D 1003 and specific gravity as per STM D 792. Polycarbonate sheet shall have foam tap or s rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates include of all material, labour, fittings, screw, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof.Supply, fabrication and erection of three-dimensional space frame steel structure consisting of support node, primary space frame members, space notes nodes, bolts, sleeves (nut), purlin stool, purlin etc. to support roof sheet in plain or curved shape. (Approximate zinc coating thickness 77 Microns) and shall not be less than 400 g/sqm (Approximate zinc coating thickness 56 microns). Bolts, sleeves and cones shall be electro-galvanized to ASTM B 633 Type 2, SC3. Shop drawings along with structural design analysis shall be provided by the manufacturer for approval of the engineer in charge. Rate shall include cost of design, all material, all lifts, abour, transport, storage, machines, tools and plants, wastages, erection and installation at site all necessary scaffolding etc. necessary to provide finished product but excluding cost of erection/construction of support shaft and roof sheet. «Providing nd fixing rooofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).ÒProviding and fixing in position roof tile under lay using 12mm thick(minimum) Moisture/fire Resistance heavy duty fibre cement board(High Pressure Steam Cured) Type A,Category 4 conforming to IS 14862:2000, fixed on Steel frame work of 610mmx610mm or 610mmx1220mm grid by counter sunk stainless screw @ 300mm C/C all complete as per the drawings. The boards are to be fixed on the frame work in staggered manner keeping a uniform gap of 2mm.Finally, the roof tile like Shingles/Mangalorian Tiles etc may be laid on the board substrate by sealing the joints properly with filler material or sealant to ensure no leakage through joints. All completeas per drawings, specification and as per direction of Engineer-in-Charge.jNote - MS Section structure and roof tile like Shingles/Mangalorian Tiles etc cost will be paid seprately.Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building .¼@½=-Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183, density 16kg/m3, 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire.@=Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge :12.44.1 With Type N - Normal 50 mm thick12.44.28With Type SE - Self Extinguishing type 50 mm thick.âProviding and laying thermal insulation of roofing with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 mx2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. vProviding and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8
183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in- Charge.@=¢Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building.Æ@Ç=Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire. @=Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge¸Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.58.1H10mm thick plaster of Paris(gypsum anhydrous) sheet 10mm thick pop board 12.58.1.1Flat surfaces 12.58.1.2Curved surfaces 12.58.1.3Sunk or raised mouldings 12.58.1.4|Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level.sqm per mtr height 12.58.2,12.5 mm thick tapered edge gypsum board 12.58.2.1mPlain board conforming to IS: 2095- Part I : 2011 (Board with BIS certification marks). 12.58.2.2Fire resistant Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) 12.58.2.3 Gypsum moisture resistant board. 12.58.2.4BFully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.12.58.3¹8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of mainT" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 Ûx1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sec etal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screwsat 300mm center to centre, suspending the main C carrier and in direction perpendicular to it at 600mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive) Fixing with clip in/swing down tiles into spring 'T' with 12.60.1ßGI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.12.60.2ÏGI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.Providing & Fixing of Unperforated Antibacterial Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.7mm thick aluminium alloy 3105 with beveled edge of 4.15mm width and height of 32mm. The Tile will be manufactured on advanced equipment that includes several levelling stages in the manufacturing process by approved certified manufacturers. The Tile shall be clipped into clip in rail of 0.5mm thick G.I. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G.I.Road, Hold on Clamp with Clip. (Rate include all materials and labour).Providing and fixing board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately):12.62.112mm thick insulating board 12.62.1.1Natural colour insulating board550..00= 12.62.1.2White face insulating board 12.62.1.3%Flame retardant face insulating board12.62.2±Flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 12 mm thick marked in ceiling with necessary nails etc. complete12.62.3»6 mm thick plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete12.62.4ê6mm thick High Pressure Steam Cured non asbestos, reinforced with cellulose fibres,Moistur& fire Resistance heavy duty fibre cement board, Type A,Category 4 conforming to IS 14862:2000.(for wet areas)12.62.5æ4 mm thick High Pressure Steam Cured non asbestos, pre-painted, self- embossed, designer cement boardType B, Category 3 conforming to IS 14862:2000 . of approved texture,design patterns¢Extra for Circular cutting and wastages in ceiling with: board only (frame work) Natural colour insulating 12 mm thick board paid separately.JExtra for providing and fixing ceiling to curved surfaces in narrow widthsìProviding and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminium primer on both sides and edges including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately). Providing and Fixing colour coated profile sheet of minimum 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle ®square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. The sheet shall be fixed using self- drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape ÀExtra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain or design particle board ceiling tiles.wProviding and fixing expanded polystyrene (thermacol) false ceiling (frame work to be paid separately) :12.68.112.68.29With Type SE - Self Extinguishing type 50 mm thickProviding and fixing false ceiling with fabric fixing with nail etc. (frame work and beading to be paid separately).12.69.1costing upto 70/- per metre,12.69.2Rs 70- 150 per metersqm 12.69.3 Upto 200 per meter oProviding and fixing perforated Aluminium panel ceiling of white/ natural satin colour supplied by approved manufacturers consisting of panel of standard size with bevel edge, panel length up to 6 m, coil Coated on a Continuous Paint Line suitable for Interior application, double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 5050 (Al. Mg) for higher strength and good roll forming characteristics. Panel carrier shall be suspended by means of G.I. threaded rod having 6 mm diameter at a distance of 1.5 mtr. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.70.1With panels of size 300mm wide X30mm deep X 0.7mm thick and panel carrier of size 40.5mm wide X 62mm deep X 0.9mm thick12.70.2With panels of size 150mm wide X 15.5 mm deep X 0.5mm thick and panel carrier of size 32mm wide X 39mm deep X 0.95mm thick12.70.3With panels of size 84mm wideX16mm deep X 0.5mm thick and panel carrier of size 62mm wide X 29mm deep X 0.95mm thickËProviding and fixing un-perforated Aluminium Panel ceiling Supplied by approved manufacturers of standard white/ natural satin shade consisting of panel 30 mm/80mm/130mm/180mm wide X 15 mm deep X 0.5mm /0.6mm thick respectively, with square edges having panel len sqm 2775
gth up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 5050 (Al.Mg) for higher strength and good roll forming characteristics. The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter, and a Galvanised suspension spring clip at a distance of 1.7mtrs centre to centre. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc.fProviding and fixing U Baffle Aluminium panel ceiling of different colors and finish supplied by approved manufacturers, consisting of panel size 50 mm width X 100 mm deep using 0.6 mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al.Mg) for higher strength and good roll forming characteristics. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The measurements shall be wall to wall without any deductions for lights, diffuses, columns etc.As an option, ceiling area above U Baffle can be painted by the contractor in black colour or any other colour as per the architect for better aesthetics before fixing this system.12.72.1$Standard White / Natural Satin Shade12.72.2Wooden FinishpSupply & Fixing of perforated G.I false ceiling tile or plank using torsion spring fixing system supplied by approved manufacturer comprising of tile of 600 mm wide and 600 mm long manufactured out of 0.5 mm thick or plank of 600mm wide and 1200 mm long manufactured out of 0.6mm thick galvanised steel perforated with 2 mm dia. at a distance of 5mm centre to centre. Non-woven felt made of glass- reinforced fibre glued over the perforation at the back side of panels to provide noise reduction co efficient up to 0.7 NRc. Tee sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross runners 24 mm deep, inverted Tee sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced at a spacing of 600 mm on centre maximum. The measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.73.19Tile of 600 mm wide ,600 mm long and 0.5 mm thick12.73.21Plank of 600mm wide ,1200 mm long and 0.6mm thick¾Providing and fixing of composite perforated Gypsum board with Glass wool Fiber panel of Size 595x595x25 mm with 10mm square Perforation tiles false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main T runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge.ÄProviding and fixing of Composite perforated MDF board with Glass wool Fiber panel of Size 595x595x18 mm 10mm Square Perforation tiles (Square /Tegular Edge) false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main T runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. ÔProviding and fixing of Perforated Gypsum board with Acoustical Glass Fiber Tissue faced panel of Size 595x595x12.5mm, Square 10mm Pe rforation tiles (Square Edge) false ceiling panels in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge.倀潲楶楤杮†湡映硩湩映污敳†散汩湩愠⁴污栠楥桧獴†楷桴†㔱†浭†桴捩椠瑮来慲敤獮晩敩†††整畧慬†††摥敧†††潮挠浥湥楴楴畯†氠杩瑨渠†眠楥桧⁴†挠污楣浵猠汩捩瑡†慦獬†散汩湩†楴敬†爠楥普牯散楷桴†映扩敲†愠摮†渠瑡牵污†映汩敬†慦獬散汩湩琠汩獥†景†楓敺†㤵砵㤵‵洠漠灡牰癯摥†整瑸牵ⱥ†敤楳湧†湡瀠瑡整湲慨楶杮††丠䍒††⠠潎獩††敒畤瑣潩潣晥楦楣湥⥴漠⸰〵⠠業楮畭⥭愠数卉†㠠㈲㨵㤱㜸 〵洠潬杮‸浭漠瑵牥搠慩敭整ⵍ㘠†搠獡†慦瑳湥牥ⱳ†㘠†洠†楤†畦汬⁹桴敲摡摥†慨杮牥†潲甠瑰ㄠ〰‰洠敬杮桴†湡䰠猭慨数†敬敶愠橤獵整漠楳敺㠠砵㔲㉸砵′浭慇癬湡獩摥椠潲数楲敭整††眠污††湡汧††景††猠穩㐲㉸破⸰〴洠景氠湥瑧〳〰洠潴戠映硩摥†湯†数楲桰牥⁹眠污⼠†慰瑲瑩潩楷桴†桴栠汥⁰漠瀠慬瑳捩†慲汷†汰杵愠⁴㔴‰洠挠湥整琠挠湥整愠摮†〴†浭氠湯搠祲†慷汬†⹓⁓猠牣睥†桔眠牯桳污††敢††挠牡楲摥††漠瑵††愠††数数楣楦慣楴湯ⱳ†搠慲楷杮†愠摮†愠†数楤敲瑣潩獮漠桴湅楧敮牥椭桃牡敧ਮਊе倀潲楶楤杮†湡映硩湩映污敳†散汩湩愠⁴污栠楥桧獴†楷桴†㔱†浭†桴捩椠瑮来慲敤獮晩敩†洠捩潲††潬歯††摥敧†渠湯散敭瑮瑩潩獵††楬桧⁴†眠楥桧⁴†挠污楣浵猠汩捩瑡†慦獬†散汩湩†楴敬†爠楥普牯散楷桴†映扩敲†愠摮†渠瑡牵污†映汩敬†慦獬散汩湩琠汩獥†景†楓敺†㤵砵㤵‵洠漠灡牰癯摥†整瑸牵ⱥ†敤楳湧††桔眠牯桳污††敢††挠牡楲摥††漠瑵††愠††数灳捥晩捩瑡潩獮†牤睡湩†湡†獡†瀠牥搠物捥楴湯景琠敨䔠杮湩敥湩䌭慨杲〸朠慲獭瀠牥猠浱 㔠‰浭氠湯Ⱨㄠ′浭漠瑵牥搠慩敭整ⵍ‶慤桳映獡整敮獲眠瑩桴敨灬漠⁚汣慥⁴景㈠砷㜳㉸砷′浭㘠†浭†楤映汵祬†桴敲摡摥†慨杮牥爠摯甠瑰〱〰洠敬杮桴愠摮䰠猭慨数氠癥汥愠橤獵整景猠穩㔸㉸砵㔲㉸洠䜠污慶楮敳椠潲瀠牥浩瑥牥†慷汬†湡汧景猠穩㈲ㅸ砹⸰〴洠景氠湥瑧〳〰洠琠戠映硩摥†湯†数楲桰牥⁹眠污⼠瀠牡楴楴湯†楷桴†桴栠汥⁰漠瀠慬瑳捩†慲汷瀠畬獧†瑡㐠〵洠挠湥牴潴挠湥牴湡〴浭†潬杮†牤⁹眠污匠匮†捳敲獷吠敨眠牯†桳污†敢†挠牡楲摥†漠瑵†愠†数灳捥晩捩瑡潩獮†牤睡湩†湡†獡†瀠牥搠物捥楴湯景琠敨䔠杮湩敥湩䌭慨杲П倀潲楶楤杮愠摮映硩湩慦獬散汩湩瑡愠汬栠楥桧獴†眠瑩†㔱†洠†桴捩†湩整牧污搠湥楳楦摥†洠物汯潯†摥敧†眠瑩†䥂⁏䅓䕆†潣瑡湩愠瀠牥†卉⁏㜠㔲㨱〲㔰卉⁏†〲㐷㨳〲㜰†愠摮†䤠体†㈠㔱㜲ㄭ㈺〰ⰸ†慭楫杮†桴琠汩獥†敲楳瑳湡⁴琠慢瑣牥慩†朠潲瑷†椠†挠獡†漠†愠祮攠瑸牥慮戠捡整楲污†潣瑮捡⁴洠摡漠瑮桴猠牵慦散†景†楴敬ⱳ†潮散敭瑮瑩潩獵氠杩瑨†眠楥桧⁴†慣捬畩†楳楬慣整†映污敳挠楥楬杮†楴敬†敲湩潦捲摥†楷桴†楦牢愠摮渠瑡牵污映汩敬慦獬散汩湩楴敬景匠穩㤵砵㤵‵†浭††楷桴琠敨栠汥⁰景娠挠敬瑡漠㜲㍸砷㜲㉸洠Ɑ†‶洠搠慩†畦汬⁹琠牨慥敤栠湡敧潲灵潴ㄠ〰‰浭氠湥瑧湡ⵌ桳灡敬敶摡番瑳牥漠楳敺㠠砵㔲㉸砵′浭慇癬湡獩摥†物湯†数楲敭整眠污愠杮敬漠楳敺㈠砲㤱へ㐮‰浭漠敬杮桴㌠〰‰浭†潴†敢†楦數漠瀠牥灩敨祲†慷汬† 慰瑲瑩潩眠瑩琠敨†敨灬†景†汰獡楴爠睡汰杵愠⁴㔴‰浭†散瑮敲琠散瑮敲愠摮㐠洰氠湯搠祲†慷汬†⹓⁓猠牣睥†桔潷歲†猠慨汬†戠†慣牲敩†畯⁴†獡†瀠牥猠数楣楦慣楴湯ⱳ†搠慲楷杮†愠摮†愠†数楤敲瑣潩獮漠桴湅楧敮牥椭桃牡敧ਮਊਊҀ倀潲楶楤杮†湡映硩湩椠瀠獯瑩潩眠污慰敮汬湩愠⁴愠汬†敨杩瑨眠瑩ㄠ‵洠桴捩畦汬⁹数晲牯瑡摥猠畱牡⽥畢瑴攠杤楬桧⁴眠楥桧⁴挠污楣浵†楳楬慣整†慰敮獬 楴敬†渠湯挭浥湥楴楴畯ⱳ††敲湩潦捲摥眠瑩映扩敲†湡渠瑡牵污†楦汬牥栠癡湩剎⁃丨楯敳删摥捵楴湯䌠敯晦捩敩瑮 景〠ㄮⴰ⸰〲映牯瀠慬湩愠摮搠獥杩敮⸰㔱〭㐮‰†潦†楰桮汯†整瑸牵†湡†剎⁃⸰㔴〭㘮‵映牯†畦汬⁹瀠牥潦慲整琠汩獥†獡瀠牥†卉†㈸㔲ㄺ㠹ⰷ†潳湵愠瑴湥慵楴湯匠䅔㌭搲†景†⸰㔷†洨湩浩浵 愠瀠牥䤠⁓㠠㈲㨵㤱㜸†楌桧⁴删晥敬瑣湡散†景㠠┵†洨湩浩浵Ⱙ†潮潣扭獵楴汢愠数卂㐺㘷⠠慰瑲㐭Ⱙ㔠ⴰ㈵‥敲祣汣摥挠湯整瑮††椠据畬楤杮††映祬††愠桳吠敨樠楯瑮戠瑥敷湥†桴瀠湡汥牡琠戠搠汵⁹樠楯瑮摥†湡映湩獩敨獵湩爠捥浯敭摮摥†潪湩楴杮†慣捬畩楳楬慣整†戠獡摥†挠浯潰湵†湡†楦牢潪湩⁴琠灡爠汯㔠洰†眠摩†††††㤨‰敭牴⥥†潲汬†湡琠潷†潣瑡漠瀠楲敭畳瑩扡敬††映牯††瀠湡汥楬杮††愠††数慭畮慦瑣牵牥猧†猠数楣楦慣楴湯†愠†数楤敲瑣潩†漠†攠杮湩敥湩挭慨杲†愠汬挠浯汰瑥†圠瑩†㔱†洠†桴捩†畦汬⁹数晲牯瑡摥††煳慵敲戯瑵⁴†攠杤†氠杩瑨眠楥桧⁴慣捬畩楳楬慣整瀠湡汥⽳琠汩獥ਮ㴊牐癯摩湩…楦楸杮映污敳挠楥楬杮愠⁴污敨杩瑨楷桴䜠䝒⠠汇獡楆牢敒湩潦捲摥䜠灹畳⥭映污敳挠楥楬杮琠汩獥漠楓敺㔠㔹㕸㔹洠景愠灰潲敶整瑸牵ⱥ搠獥杩湡慰瑴牥獮栠癡湩潭獩畴敲挠湯整瑮氠獥桴湡㈠Ⱕ栠浵摩瑩⁹敲楳瑳湡散漠㤹Ⱕ丠䍒⸰〵琠⸰㔷愠数卉㠠㈲㨵㤱㜸潎据浯畢瑳扩敬愠数卂㐠㘷⠠慰瑲㐠ㄠ㜹‰湡楬桧⁴敲汦捥慴据景㠠┵⠠業楮畭⥭琠敢氠楡湩琠畲潨楲潺瑮污氠癥汥猠獵数摮摥漠湩整汲捯楫杮洠瑥污吠䜭楲景栠瑯搠灩数慧癬湡獩摥椠潲敳瑣潩景〠㌮洳桴捩木污慶楮敺ㅀ〲朠慲獭瀠牥猠浱椠据畬楤杮戠瑯楳敤⥳挠浯牰獩湩景洠楡⁔畲湮牥景 sqm 2675
ㄠ砵㈳洠景氠湥瑧〳〰洠Ɑ挠潲獳ⴠ吠漠楳敺ㄠ砵㈳洠景氠湥瑧㈱〰洠湡敳潣摮牡⁹湩整浲摥慩整挠潲獳⁔景猠穩㔱㍸′浭漠敬杮桴㘠〰浭琠潦浲朠楲潭畤敬漠楳敺㘠〰砠㘠〰浭畳灳湥敤牦浯挠楥楬杮甠楳杮朠污慶楮敳†業摬†猠整汥†椠整獭木污慶楮楺杮䀠㠠‰牧浡数煳⥭椠攮〵洠潬杮‸浭漠瑵牥搠慩敭整ⵍ㘠搠獡慦瑳湥牥ⱳ㘠洠楤畦汬⁹桴敲摡摥栠湡敧潲灵潴ㄠ〰‰浭氠湥瑧湡ⵌ桳灡敬敶摡番瑳牥漠獦穩㔸㉸砵′浭慇癬湡獩摥椠潲数楲敭整慷汬愠杮敬漠楳敺㈠破㐲へ㐮‰浭漠敬杮桴㌠〰‰浭琠敢映硩摥漠数楲桰牥⁹慷汬⼠瀠牡楴楴湯眠瑩桴敨灬漠汰獡楴慲汷瀠畬獧愠⁴㔴‰浭挠湥整潴挠湥整湡〴洠潬杮搠祲眠污潷摯猠牣睥吠敨眠牯桳污敢挠牡楲摥漠瑵愠数灳捥晩捩瑡潩獮牤睡湩湡獡瀠牥搠物捥楴湯景琠敨䔠杮湩敥湩桃牡敧ਮ⸲ㄸㄮL圀瑩敳業瀠牥潦慲整㈱浭琠楨正洠捩潲琠来汵牡攠杤摥䜠䝒映污敳挠楥楬杮琠汩獥ܮ㈱㠮⸱挲楗桴映汵祬瀠牥潦慲整〱浭琠楨正猠畱牡摥敧則⁇慦獬散汩湩楴敬潦潳湵牰潯湡捡畯瑳捩뀮ăProviding and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped 387alvanized steel sections (387alvanized387 @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre tocentre, and cross “T” of size 24x28mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mmpanel to from grid of size 600x600 mm, resting on periphery walls/ partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000Ӟ洁洀 洀愀搀攀 漀昀 ⸀㐀 洀洀 琀栀椀挀欀 ⠀洀椀渀椀洀甀洀⤀ 猀栀攀攀琀 眀椀琀栀 琀栀攀 栀攀氀瀀 漀昀 爀愀眀氀瀀氀甀最猀 愀琀 㐀㔀 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 眀椀琀栀 ㈀㔀 洀洀 氀漀渀最 搀爀礀 眀愀氀氀 猀挀爀攀眀猀 䀀 ㈀㌀ 洀洀 椀渀琀攀爀瘀愀氀 愀渀搀 氀愀礀椀渀最 㔀 洀洀 琀栀椀挀欀 搀攀渀猀椀昀椀攀搀 攀搀最攀猀 ㌀㠀㠀愀氀瘀愀渀椀 猀椀氀椀挀愀琀攀 挀攀椀氀椀渀最 琀椀氀攀猀 漀昀 愀瀀瀀爀漀瘀攀搀 琀攀砀琀甀爀攀 椀渀 琀栀攀 最爀椀搀Ⰰ 椀渀挀氀甀搀椀渀最Ⰰ 挀甀琀琀椀渀最⼀ 洀愀欀椀渀最 漀瀀攀渀椀渀最 昀漀爀 猀攀爀瘀椀挀攀猀 氀椀欀攀 搀椀昀昀甀猀攀爀猀Ⰰ 最爀椀氀氀猀Ⰰ 氀椀最栀琀 昀椀琀琀椀渀最猀Ⰰ 昀椀砀琀甀爀攀猀Ⰰ 猀洀漀欀攀 搀攀琀攀挀琀漀爀猀 攀琀挀⸀Ⰰ 眀栀攀爀攀瘀攀爀 爀攀焀甀椀爀攀搀⸀䴀愀椀渀 ᠀吠ᤀ†爀甀渀渀攀爀猀 琀漀 戀攀 猀甀猀瀀攀渀搀攀搀 昀爀漀洀 挀攀椀氀椀渀最 甀猀椀渀最 䜀⸀䤀⸀ 猀氀漀琀琀攀搀 挀氀攀愀琀猀 漀昀 猀椀稀攀 ㈀㔀砀㌀㔀砀⸀㘀 洀洀 昀椀砀攀搀 琀漀 挀攀椀氀椀渀最 眀椀琀栀 ㈀⸀㔀 洀洀 搀椀愀 愀渀搀 㔀 洀洀 氀漀渀最搀愀猀栀 昀愀猀琀攀渀攀爀猀Ⰰ 㐀 洀洀 䜀⸀䤀⸀ 愀搀樀甀猀琀愀戀氀攀 爀漀搀猀 眀椀琀栀 ㌀㠀㠀愀氀瘀愀渀椀稀攀搀 猀琀攀攀氀 氀攀瘀攀氀挀氀椀瀀猀 漀昀 猀椀稀攀 㠀㔀 砀 ㌀ 砀 ⸀㠀 洀洀Ⰰ 猀瀀愀挀攀搀 愀琀 ㈀ 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 愀氀漀渀最 洀愀椀渀 ᠀吠ᤀⰠ 戀漀琀琀漀洀 攀砀瀀漀猀攀搀 眀椀琀栀 ㈀㐀 洀洀漀昀 愀氀氀 吀猀攀挀琀椀漀渀猀 猀栀愀氀氀 戀攀 瀀爀攀ⴀ 瀀愀椀渀琀攀搀眀椀琀栀 瀀漀氀礀猀琀攀爀 戀愀欀攀搀 瀀愀椀渀琀Ⰰ 昀漀爀 愀氀氀 栀攀椀最栀琀猀Ⰰ 愀猀 瀀攀爀 猀瀀攀挀椀昀椀挀愀琀椀漀渀猀Ⰰ 搀爀愀眀椀渀最猀 愀渀搀 愀猀 搀椀爀攀挀琀攀搀 戀礀 䔀渀最椀渀攀攀爀ⴀ 椀渀ⴀ䌀栀愀爀最攀⸀一漀琀攀 㨀ⴀ 伀渀氀礀 挀愀氀挀椀甀洀 猀椀氀椀挀愀琀攀 昀愀氀猀攀 挀攀椀氀椀渀最 愀爀攀愀 眀椀氀氀 戀攀 洀攀愀猀甀爀攀搀 昀爀漀洀 眀愀氀氀 琀漀 眀愀氀氀⸀ 一漀 搀攀搀甀挀琀椀漀渀 猀栀愀氀氀 戀攀 洀愀搀攀 昀漀爀 攀砀瀀漀猀攀搀 昀爀愀洀攀猀⼀ 漀瀀攀渀椀渀最 ⠀挀甀琀 漀甀琀猀⤀ 栀愀瘀椀渀最 愀爀攀愀 氀攀猀猀 琀栀愀渀 ⸀㌀ 猀焀洀⸀吀栀攀 挀愀氀挀椀甀洀 猀椀氀椀挀愀琀攀 挀攀椀氀椀渀最 琀椀氀攀 猀栀愀氀氀 栀愀瘀攀 一刀䌀 瘀愀氀甀攀 漀昀 ⸀㔀 ⠀䴀椀渀椀洀甀洀⤀Ⰰ 氀椀最栀琀 爀攀昀氀攀挀琀椀漀渀 㸀 㠀㔀─Ⰰ 渀漀渀ⴀ 挀漀洀戀甀猀琀椀戀氀攀 愀猀 瀀攀爀 䈀⸀匀⸀ 㐀㜀㘀 瀀愀爀琀 䤀嘀Ⰰ ─ 栀甀洀椀搀椀琀礀 爀攀猀椀猀琀愀渀挀攀 愀渀搀 愀氀猀漀 栀愀瘀椀渀最 琀栀攀爀洀愀氀 挀漀渀搀甀挀琀椀瘀椀琀礀᐀牐癯摩湩湡楦楸杮甠癰汰湡Ⱬ倠慬歮猠穩㌨〴堠㈠〷‰ 浭愠数灡牰癯摥猠慨敤桴慰敮桳污敢氠獡牥挠瑡整湥景瀠慬歮映硩湩牴浩映硩摥愠摮挠牯敮摥敧漠散汩湩楦數⁵癰汣灩猠浡潣潬牵愠摮瀠潲楶楤杮愠摮映硩湩景映慲敭眠牯慭敤漠灳捥慩敳瑣潩獮潰敷牰獥敳牦浯䴠匮桳敥獴愠摮朠污慶楮敺楷桴稠湩潣瑡湩景ㄠ㔲朠獭猯浱⠠潢桴猠摩湩汣獵癩⥥愠数卉㨠㈠㜷愠摮挠湯楳瑳湩景愠杮敬挠敬瑡景猠穩㔲洠楷敤砠ㄠ㘮洠桴捩楷桴映慬杮獥漠㜲洠湡㜳浭瑡ㄠ〲‰浭挠湥牴潴挠湥牴ⱥ漠敮映慬杮楦數潴ʗ琀敨挠楥楬杮眠瑩慤桳映獡整敮㈱㔮洠楤⁸〵浭氠湯楷桴㘠浭搠慩戠汯獴漬桴牥映慬杮景挠敬瑡映硩摥琠桴湡汧慨杮牥景㈠砵〱へ㔮‰浭漠敲畱物摥氠湥瑧楷桴渠瑵…潢瑬景爠煥極敲楳敺愠摮漠桴牥攠摮漠湡汧慨杮牥映硩摥眠瑩湩整浲摥慩整䜠䤮档湡敮獬㐠砵㔱へ㤮洠畲湮湩瑡琠敨猠慰楣杮漠㈱〰洠散瑮敲琠散瑮敲潴眠楨档琠敨挠楥楬杮猠捥楴湯〠㔮洠桴捩潢瑴浯眠摥敧漠〸洠楷桴琠灡牥摥映慬杮獥漠㘲洠慥档栠癡湩楬獰漠〱㔮洠Ɑ愠⁴㔴‰浭挠湥牴潴挠湥牴ⱥ猠慨汬戠楦數湩愠搠物捥楴湯瀠牥数摮捩汵牡樬琠楲湥汣灩椠据畬敤湩琠楨瑩浥愠祮漠桴牥椠整潮⁴敢瀠楡敳牰瑡祬挠浯汰瑥湩愠汬爠獥数瑣愠数桴楤敲瑣潩獮漠湅楧敮牥椭桃牡敧Μ倁爀漀瘀椀搀椀渀最 ☀ 䘀椀砀椀渀最 倀嘀䌀 挀攀椀氀椀渀最猀礀猀琀攀洀 瀀爀漀昀椀氀攀 瀀愀渀攀氀 眀椀琀栀 挀氀椀挀欀 猀礀猀琀攀洀椀渀琀攀爀氀漀挀欀 瀀愀渀攀氀 猀椀稀攀 㐀 洀洀砀㌀㐀 洀洀砀洀洀 爀攀猀椀猀琀愀渀挀攀 琀漀 眀攀愀琀栀攀爀 瀀攀爀昀攀挀琀 昀椀渀椀猀栀 椀渀 眀漀漀搀 最爀愀椀渀 ☀ 猀漀氀椀搀 挀漀氀漀甀爀 洀愀椀渀琀攀渀愀渀挀攀 昀爀攀攀 刀攀猀椀猀琀愀渀挀攀 琀漀 眀攀愀琀栀攀爀 琀爀甀氀礀 愀渀琀椀 戀愀挀琀攀爀椀愀氀⸀ 眀椀琀栀 攀搀最攀 瀀爀漀昀椀氀攀 䨀ⴀ琀爀椀洀 漀渀 瀀攀爀椀瀀栀攀爀礀 ☀ 挀攀渀琀攀爀 瀀爀漀昀椀氀攀 吀ⴀ琀爀椀洀 椀渀 瀀愀渀攀氀 樀漀椀渀琀 䌀漀洀瀀氀攀琀攀 匀礀猀琀攀洀 琀漀 戀攀 昀椀砀攀搀 漀渀 䜀⸀䤀⸀ 昀爀愀洀攀眀漀爀欀 漀昀 挀攀椀氀椀渀最猀攀挀琀椀漀渀 愀琀 㐀㔀 洀洀 搀椀猀琀愀渀挀攀 眀椀琀栀 攀渀琀攀爀 猀攀挀琀椀漀渀 猀甀猀瀀攀渀搀攀搀 戀礀 爀漀漀昀 戀礀 䜀⸀䤀⸀ 愀渀最氀攀 栀愀渀最攀爀 椀渀 瀀爀漀瀀攀爀 氀椀渀攀 ☀ 氀攀瘀攀氀 攀琀挀 挀漀洀瀀氀攀琀攀 倀刀伀䐀唀䌀吀 倀䔀䌀䤀䘀䤀䌀䄀吀䤀伀一匀㨀䴀攀攀琀猀 漀爀 攀砀挀攀攀搀猀 琀栀攀 猀琀愀渀搀愀爀搀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 漀昀 ⠀䄀匀吀䴀 䐀ⴀ㐀㐀㜀㜀⤀ 愀渀搀 椀琀猀 爀攀昀攀爀攀渀挀攀搀 搀漀挀甀洀攀渀琀猀⸀ 䤀洀瀀愀挀琀 爀攀猀椀猀琀愀渀挀攀㨀 一漀 搀攀昀漀爀洀愀琀椀漀渀漀戀猀攀爀瘀攀搀⸀ ⠀吀攀猀琀攀搀 愀琀 㔀 䰀䈀匀⤀ 吀攀渀猀椀氀攀 猀琀爀攀渀最琀栀Ⰰ 䴀倀愀㨀 㸀㌀㜀⸀ 吀攀渀猀椀氀攀 洀漀搀甀氀甀猀Ⰰ 䴀倀愀㨀 㸀㈀ 匀甀爀昀愀挀攀 搀椀猀琀漀爀琀椀漀渀㨀 一漀渀攀 愀琀 ㈀ 䘀 匀焀甀愀爀攀渀攀猀猀㨀 㰀⼀㠀ᴀ†漀昀 猀焀甀愀爀攀䰀攀渀最琀栀㨀 圀椀琀栀椀渀 밀ᴀ†漀昀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 䰀漀挀欀 挀漀渀琀爀漀氀㨀 䌀漀洀瀀氀椀攀猀 䌀漀氀漀爀 䌀栀愀渀最攀㨀 㰀㈀ 最爀愀礀猀挀愀氀攀猀 ⠀㘀 栀爀猀 甀渀搀攀爀 ㈀ 圀⼀洀㈀ 唀嘀 爀愀搀椀愀琀椀漀渀 愀琀 㔀 搀攀最爀攀攀猀⤀ 需ĄProviding & Fixing of Mineral Fibre 1200x300mm (Nominal Size) tiles Acoustical Suspended Ceiling System with 16mm thick Beveled Tegular Edge Tiles and 15mm Bolt Slot Exposed Grid. The tiles shall have fissured visual with acoustical punctures, Humidity Resistance (RH) of 99%, NRC 0.6 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C- 423 standard, CAC of 35db as per ASTM E1414, Light Reflectance 87% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 0/7 and Class A as per ASTM E84 with 16mm Beveled Tegular edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building sqm 2575
425 9.214 application, with Recycled content of 32%. The tile shall have certifications from GRIHA/ green pro etc and SUSPENSION The tile shall be laid on grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour with metered ends & “bird's mouth” notches to provide mitred cruciform junctions colour global white (Matching to tile color). Grid shall have double stroke rotary stitching on all T sectionsDž椁⸀攀⸀ 琀栀攀 䴀愀椀渀 刀甀渀渀攀爀 ☀ ㈀ 洀洀 䌀爀漀猀猀 吀攀攀猀 眀椀琀栀 愀 吀栀攀 搀攀昀氀攀挀琀椀漀渀 氀漀愀搀椀渀最 漀昀 琀栀攀 猀礀猀琀攀洀 猀栀愀氀氀 戀攀 㜀⸀㤀 欀最⼀洀㈀ ⠀愀猀 瀀攀爀 猀琀愀渀搀愀爀搀 椀渀猀琀愀氀氀愀琀椀漀渀 氀愀礀漀甀琀 洀攀渀琀椀漀渀攀搀 戀攀氀漀眀⤀ 愀渀搀 洀愀椀渀 戀攀愀洀 琀攀猀琀攀搀 愀猀 瀀攀爀 䄀匀吀䴀 䌀㘀㌀㔀 ⠀䐀攀昀氀攀挀琀椀漀渀 氀椀洀椀琀 氀攀猀猀 琀栀愀渀 䰀⼀㌀㘀 ⤀ 眀椀琀栀 愀 搀攀昀氀攀挀琀椀漀渀 氀漀愀搀椀渀最 漀昀 㤀⸀㔀 欀最⼀洀⸀ 吀栀攀 攀渀搀 搀攀琀愀椀氀猀 漀昀 琀栀攀 挀爀漀猀猀 琀攀攀 猀栀愀氀氀 戀攀 洀愀搀攀 漀昀 瀀爀攀 栀愀爀搀攀渀攀搀 猀琀攀攀氀 挀氀椀瀀 昀椀砀攀搀 琀漀 琀栀攀 攀渀搀猀 漀昀 琀栀攀 挀爀漀猀猀 琀攀攀 琀漀 瀀爀漀瘀椀搀攀 搀漀甀戀氀攀 氀漀挀欀椀渀最 戀攀琀眀攀攀渀 ᰀ挠爀漀猀猀 琀攀攀 琀漀 挀爀漀猀猀 琀攀攀ᴀ†愀渀搀 ᰀ挠爀漀猀猀 琀攀攀縀Ćto main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull-out strength of mare than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of OT {Jemlfng capability. ,lj\|STALLATlON To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspen9ion system (specifications below) at 1200mm maximum. The First/ Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and tha last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 1200mm to form 1200 x 1200 mm module. Cut cross tees longef than 600mm require independent support. 1200 x 300mm module to be formed by fittinB 1200mm long flush fi\ting cross tees (with no mitre cut on cross tees) centrally between the 1200 mm cross tees(Miter cut at every 300 mm). Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure.SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia - 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 1 10 kgs. (Optionally, adjustable hook dips made of 0.7mm thick Grade 1 C55 galvanized spring eteel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). ͑倀潲楶楤杮☠䘠硩湩景䴠湩牥污䘠扩敲䄠潣獵楴慣畓灳湥敤敃汩湩祓瑳浥眠瑩業楮畭㐱琠㔱洠桴捩敂敶汬摥吠来汵牡䔠杤楔敬湡㔱浭䘠捡硅潰敳片摩桔楴敬桳污慨敶䄠獳牵摥瘠獩慵楷桴愠潣獵楴慣異据畴敲畈業楤祴删獥獩慴据⠠䡒 漠㤠┵丠䍒〠㔮⠠癁牥条慶畬景䄠獢牯瑰潩潃攭晦捩敩瑮爠慥楤杮慴敫瑡㈠〵䠠ⱺ㔠〰䠠ⱺㄠ〰‰穈愠摮㈠〰‰穈 獡瀠牥䄠呓⁍ⵃ㈴″瑳湡慤摲䅃⁃景㌠搰獡瀠牥䄠呓⁍ㅅㄴⰴ䰠杩瑨删晥敬瑣湡散㠠┵愠数十䵔䔠㐱㜷吠敨浲污†潃摮捵楴楶祴欠†⸰㔰′⸰㔰‷⽗䭭潃潬牵䜠漩慢桗瑩ⱥ䘠物敐晲牯慭据景挠慬獳〠ㄯ愠数卂㐠㘷倠牡⁴⼶‷湡汃獡⁁獡瀠牥䄠呓⁍㡅‴楷桴ㄠ洵敂敶汬摥吠来汵牡攠杤湡洸牤灯椠潭畤敬猠穩景㘠〰砠㘠住浭瑉猠慨汬戠畳瑩扡敬映牯䜠敲湥䈠極摬湩灡汰捩瑡潩Ɱ眠瑩敒祣汣摥挠湯整瑮漠〳⸥吠敨琠汩桳污慨敶挠牥楴楦慣楴湯牦浯䜠䥒䅈 片敥偮潲攠捴啓偓久䥓乏›ݡ吁渀攀 攀渀搀 搀攀琀愀椀氀猀 漀昀 琀栀攀 挀爀漀猀猀 琀攀攀 猀栀愀氀氀 戀攀 洀愀搀攀 漀昀 瀀爀攀 栀愀爀搀攀渀攀搀 猀琀攀攀氀 愀渀搀 昀椀砀攀搀 琀漀 琀栀攀 攀渀搀猀 漀昀 琀栀攀 挀爀漀猀猀 琀攀攀 琀漀 瀀爀漀瘀椀搀攀 搀漀甀戀氀攀 氀漀挀欀椀渀最 戀攀琀眀攀攀渀 ᰀ挠爀漀猀猀 琀攀攀 琀漀 挀爀漀猀猀 琀攀攀ᴀ†愀渀搀 ᰀ挠爀漀猀猀 琀攀攀 琀漀 洀愀椀渀 戀攀愀洀ᴀ⸠ 䄀氀氀 洀愀椀渀 戀攀愀洀 琀漀 洀愀椀渀 戀攀愀洀 愀渀搀 挀爀漀猀猀 琀攀攀 琀漀 挀爀漀猀猀 琀攀攀 挀漀渀渀攀挀琀椀漀渀 猀栀愀氀氀 栀愀瘀攀 愀 瀀甀氀氀 漀甀琀 猀琀爀攀渀最琀栀 漀昀 洀漀爀攀 琀栀愀渀 欀最⸀ 吀栀攀 吀 匀攀挀琀椀漀渀猀 猀栀愀氀氀 戀攀 洀愀搀攀 漀昀 栀漀琀 搀椀瀀瀀攀搀 最愀氀瘀愀渀椀稀攀搀 猀琀攀攀氀 漀昀 㤀 最猀洀 愀猀 瀀攀爀 䤀匀 ㈀㜀㜀 ⠀㈀ ㌀⤀ 愀渀搀 瀀爀攀ⴀ瀀愀椀渀琀攀搀 猀琀攀攀氀 眀椀琀栀 戀愀欀攀搀 瀀漀氀礀攀猀琀攀爀 瀀愀椀渀琀 眀椀琀栀 伀吀 戀攀渀搀椀渀最 挀愀瀀愀戀椀氀椀琀礀⸀ 䄀氀氀 戀漀爀搀攀爀 挀爀漀猀猀 琀攀攀⼀洀愀椀渀 戀攀愀洀 猀栀愀氀氀 戀攀 氀攀瘀攀氀氀攀搀 甀猀椀渀最 瀀攀爀椀洀攀琀攀爀 昀椀氀氀⸀ 䤀一匀吀䄀䰀䰀䄀吀䤀伀一㨀 吀漀挀漀洀瀀爀椀猀攀 洀愀椀渀 爀甀渀渀攀爀 猀瀀愀挀攀搀 愀琀 ㈀ 洀洀 猀攀挀甀爀攀尀礀 昀椀砀攀搀 琀漀 琀栀攀 猀琀爀甀挀琀甀爀愀氀 猀漀昀昀椀琀 甀猀椀渀最 猀甀猀瀀攀渀䜀椀漀渀 猀礀猀琀攀洀 ⠀猀瀀攀挀椀昀椀挀愀琀椀漀渀猀 愀戀漀瘀攀⤀ 愀琀 ㈀ 洀洀 洀愀砀椀洀甀洀⸀ 吀栀攀 䘀椀爀猀琀⼀䰀愀猀琀 猀甀猀瀀攀渀猀椀漀渀 猀礀猀琀攀洀 愀琀 琀栀攀 攀渀搀 漀昀 攀愀挀栀 洀愀椀渀 爀甀渀渀攀爀 猀栀愀氀氀 渀漀琀 戀攀 最爀攀愀琀攀爀 琀栀愀渀 㐀㔀伀洀洀 昀爀漀洀 琀栀攀 愀搀樀愀挀攀渀琀 眀愀氀氀 愀氀漀渀最 眀椀琀栀 琀栀攀 昀椀爀猀琀 愀渀搀 琀栀攀 氀愀猀琀 洀愀椀渀 戀攀愀洀 猀栀愀氀氀 戀攀 愀琀 氀攀猀猀 琀栀愀渀 㘀 洀洀 昀爀漀洀 琀栀攀 眀愀氀氀⸀ 䘀氀甀猀栀 昀椀琀琀椀渀最 ㈀ 伀洀洀 氀漀渀最 挀爀漀猀猀 琀攀攀猀 琀漀 戀攀 椀渀琀攀爀氀漀挀欀攀搀 戀攀琀眀攀攀渀 洀愀椀渀 爀甀渀渀攀爀猀 愀琀 㘀 洀洀 琀漀 昀漀爀洀 ㈀ 砀 㘀 洀洀 洀漀搀甀氀攀⸀ 䌀甀琀 挀爀漀猀猀 琀攀攀猀 氀漀渀最攀爀 琀栀愀渀 㘀 洀洀 爀攀㤀甀椀爀攀 椀渀搀攀瀀攀渀搀攀渀琀 猀甀瀀瀀漀爀琀⸀ 㘀 砀 㘀 洀洀 洀漀搀甀氀攀 琀漀 戀攀 昀漀爀洀攀搀 戀礀 昀椀琀琀椀渀
g 600mm long flush fitting cross teen centra\Iy between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be canied out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, jsre-straightened hanger wire of dia - 2.5 mm of 1.80 m length having a tensiie strength of 344-413 MPa and a minimum loading strength of 1 10 kgs. (Optionally, adjustable hook dips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 2Omm and 4 mm aquiiine wire to be used for level adjustment during installation purpose in main runners). ٶ倁爀漀瘀椀搀椀渀最 ☀ 䘀椀砀椀渀最 漀昀 䴀椀渀攀爀愀氀 䘀椀戀爀攀 䄀挀漀甀猀琀椀挀愀氀 匀甀猀瀀攀渀搀攀搀 䌀攀椀氀椀渀最 匀礀猀琀攀洀 眀椀琀栀 䈀攀瘀攀氀氀攀搀 吀攀最甀氀愀爀 䔀搀最攀 吀椀氀攀猀 漀昀 㘀洀洀 琀栀椀挀欀渀攀猀猀 愀渀搀 㔀洀洀 䈀漀氀琀 匀氀漀琀 昀愀挀攀 攀砀瀀漀猀攀搀 最爀椀搀⸀ 吀栀攀 琀椀氀攀猀 猀栀愀氀氀 栀愀瘀攀 猀愀渀搀 琀攀砀琀甀爀攀 瘀椀猀甀愀氀 眀椀琀栀 愀挀漀甀猀琀椀挀愀氀 瀀甀渀挀栀攀爀猀 Ⰰ 䠀甀洀椀搀椀琀礀 刀攀猀椀猀琀愀渀挀攀 ⠀刀䠀⤀ 漀昀 㤀㤀─Ⰰ 一刀䌀 ⸀㔀 ⠀䄀瘀攀爀愀最攀 瘀愀氀甀攀 漀昀 䄀戀猀漀爀瀀琀椀漀渀 䌀漀ⴀ攀昀昀椀挀椀攀渀琀 爀攀愀搀椀渀最猀 琀愀欀攀渀 愀琀 ㈀㔀 䠀稀Ⰰ 㔀 䠀稀Ⰰ 䠀稀 愀渀搀 ㈀ 䠀稀⤀ 愀猀 瀀攀爀 䄀匀吀䴀 䌀㐀㈀㌀ 猀琀愀渀搀愀爀搀Ⰰ 䌀䄀䌀 漀昀 ㌀㌀搀戀 愀猀 瀀攀爀 䄀匀吀䴀 䔀㐀㐀Ⰰ 䰀椀最栀琀 刀攀昀氀攀挀琀愀渀挀攀 攀㠢㔀─ 愀猀 瀀攀爀 䄀匀吀䴀 䔀ⴀ㐀㜀㜀Ⰰ 吀栀攀爀洀愀氀 䌀漀渀搀甀挀琀椀瘀椀琀礀 欀 㴀 ⸀ 㔀㈀ ⴀ ⸀ 㔀㜀 圀⼀洀䬀Ⰰ 䌀漀氀漀甀爀 䜀氀漀戀愀氀 圀栀椀琀攀Ⰰ 䘀椀爀攀 倀攀爀昀漀爀洀愀渀挀攀 漀昀 挀氀愀猀猀 ⼀ 愀猀 瀀攀爀 䈀匀 㐀㜀㘀 倀愀爀琀 㘀⼀㜀 愀渀搀 䌀氀愀猀猀 䄀 愀猀 瀀攀爀 䄀匀吀䴀 䔀㠀㐀 眀椀琀栀 㘀洀洀 戀攀瘀攀氀氀攀搀 吀攀最甀氀愀爀 攀搀最攀 愀渀搀 㠀洀洀 搀爀漀瀀 椀渀 洀漀搀甀氀攀 猀椀稀攀 漀昀 㘀 砀 㘀 洀洀⸀ 䤀琀 猀栀愀氀氀 戀攀 猀甀椀琀愀戀氀攀 昀漀爀 䜀爀攀攀渀 䈀甀椀氀搀椀渀最 愀瀀瀀氀椀挀愀琀椀漀渀Ⰰ 眀椀琀栀 刀攀挀礀挀氀攀搀 挀漀渀琀攀渀琀 漀昀 㐀 ─⸀ 吀栀攀 琀椀氀攀 猀栀愀氀氀 栀愀瘀攀 挀攀爀琀椀昀椀挀愀琀椀漀渀猀 昀爀漀洀 䜀刀䤀䠀䄀 ⼀ 䜀爀攀攀渀 倀爀漀⸀ 䔀琀挀⸀ 匀唀匀倀䔀一匀䤀伀一㨀 吀栀攀 琀椀氀攀 猀栀愀氀氀 戀攀 氀愀椀搀 漀渀 瀀爀漀昀椀氀攀 最爀椀搀 猀礀猀琀攀洀 眀椀琀栀 㔀洀洀 眀栀椀琀攀 昀氀愀渀最攀猀 椀渀挀漀爀瀀漀爀愀琀椀渀最 愀 㘀洀洀 挀攀渀琀爀愀氀 爀攀瘀攀愀氀 椀渀 眀栀椀琀攀⼀戀氀愀挀欀 挀漀氀漀甀爀 眀椀琀栀 洀椀琀爀攀搀 攀渀搀猀 ☀ ᰀ戠椀爀搀ᤀ猠 洀漀甀琀栀ᴀ†渀漀琀挀栀攀猀 琀漀 瀀爀漀瘀椀搀攀 洀椀琀爀攀搀 挀爀甀挀椀昀漀爀洀 樀甀渀挀琀椀漀渀猀 挀漀氀漀甀爀 最氀漀戀愀氀 眀栀椀琀攀 ⠀䴀愀琀挀栀椀渀最 琀漀 琀椀氀攀 挀漀氀漀爀⤀⸀ 䜀爀椀搀 猀栀愀氀氀 栀愀瘀攀 搀漀甀戀氀攀 猀琀爀漀欀攀 爀漀琀愀爀礀 猀琀椀琀挀栀椀渀最 漀渀 愀氀氀 吀 猀攀挀琀椀漀渀猀 椀⸀攀⸀ 琀栀攀 䴀愀椀渀 刀甀渀渀攀爀Ⰰ ㈀ 洀洀 ☀ 㘀 洀洀 䌀爀漀猀猀 吀攀攀猀 眀椀琀栀 愀 眀攀戀 栀攀椀最栀琀 漀昀 ㌀㠀洀洀 ⠀愀氀氀 猀攀挀琀椀漀渀猀⤀⸀ 吀栀攀 搀攀昀氀攀挀琀椀漀渀 氀漀愀搀椀渀最 漀昀 琀栀攀 猀礀猀琀攀洀 猀栀愀氀氀 戀攀 㜀⸀㤀 欀最⼀洀㈀ ⠀愀猀 瀀攀爀 猀琀愀渀搀愀爀搀 椀渀猀琀愀氀氀愀琀椀漀渀 氀愀礀漀甀琀 洀攀渀琀椀漀渀攀搀 戀攀氀漀眀⤀ 愀渀搀 洀愀椀渀 戀攀愀洀 琀攀猀琀攀搀 愀猀 瀀攀爀 䄀匀吀䴀 䌀㘀㌀㔀 ⠀䐀攀昀氀攀挀琀椀漀渀 氀椀洀椀琀 氀攀猀猀 琀栀愀渀 䰀⼀㌀㘀 ⤀ 眀椀琀栀 愀 搀攀昀氀攀挀琀椀漀渀 氀漀愀搀椀渀最 漀昀 㤀⸀㔀 欀最⼀洀⸀ 吀栀攀 攀渀搀 搀攀琀愀椀氀猀 漀昀 琀栀攀 挀爀漀猀猀 琀攀攀 猀栀愀氀氀 戀攀 洀愀搀攀 漀昀 瀀爀攀 栀愀爀搀攀渀攀搀 猀琀攀攀氀 挀氀椀瀀 昀椀砀攀搀 琀漀 琀栀攀 攀渀搀猀 漀昀 琀栀攀 挀爀漀猀猀 琀攀攀 琀漀 瀀爀漀瘀椀搀攀 搀漀甀戀氀攀 氀漀挀欀椀渀最 戀攀琀眀攀攀渀 ᰀ挠爀漀猀猀 琀攀攀 琀漀 挀爀漀猀猀 琀攀攀ᴀਠ需ăThe tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees witha web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) witha deflection loading of 15kg/m. and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of 0T bending capability. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum.ғ吁栀攀 䘀椀爀猀琀⼀䰀愀猀琀 猀甀猀瀀攀渀猀椀漀渀 猀礀猀琀攀洀 愀琀 琀栀攀 攀渀搀 漀昀 攀愀挀栀 洀愀椀渀 爀甀渀渀攀爀 猀栀愀氀氀 渀漀琀 戀攀 最爀攀愀琀攀爀 琀栀愀渀 㐀㔀 洀洀 昀爀漀洀 琀栀攀 愀搀樀愀挀攀渀琀 眀愀氀氀 愀氀漀渀最 眀椀琀栀 琀栀攀 昀椀爀猀琀 愀渀搀 琀栀攀 氀愀猀琀 洀愀椀渀 戀攀愀洀 猀栀愀氀氀 戀攀 愀琀 氀攀猀猀 琀栀愀渀 㘀 洀洀 昀爀漀洀 琀栀攀 眀愀氀氀⸀ 䘀氀甀猀栀 昀椀琀琀椀渀最 ㈀ 洀洀 氀漀渀最 挀爀漀猀猀 琀攀攀猀 琀漀 戀攀 椀渀琀攀爀氀漀挀欀攀搀 戀攀琀眀攀攀渀 洀愀椀渀 爀甀渀渀攀爀猀 愀琀 㘀 洀洀 琀漀 昀漀爀洀 ㈀ 砀 㘀 洀洀 洀漀搀甀氀攀⸀ 䌀甀琀 挀爀漀猀猀 琀攀攀猀 氀漀渀最攀爀 琀栀愀渀 㘀 洀洀 爀攀焀甀椀爀攀 椀渀搀攀瀀攀渀搀攀渀琀 猀甀瀀瀀漀爀琀⸀ 㘀 砀 㘀 洀洀 洀漀搀甀氀攀 琀漀 戀攀 昀漀爀洀攀搀 戀礀 昀椀琀琀椀渀最 㘀 洀洀 氀漀渀最 昀氀甀猀栀 昀椀琀琀椀渀最 挀爀漀猀猀 琀攀攀猀 挀攀渀琀爀愀氀氀礀 戀攀琀眀攀攀渀 琀栀攀 ㈀ 洀洀 挀爀漀猀猀 琀攀攀猀⸀倀攀爀椀洀攀琀攀爀 琀爀椀洀 琀漀 戀攀 眀愀氀氀 愀渀最氀攀猀 漀昀 猀椀稀攀 ㌀ 砀㤀砀㤀洀洀Ⰰ 猀攀挀甀爀攀搀 琀漀 眀愀氀氀猀 甀猀椀渀最 猀挀爀攀眀猀 愀琀 㐀㔀 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 洀愀砀椀洀甀洀⸀ 䤀渀猀琀愀氀氀愀琀椀漀渀 猀栀愀氀氀 戀攀 挀愀爀爀椀攀搀 漀甀琀 愀猀 瀀攀爀 䴀愀渀甀昀愀挀琀甀爀攀爀 爀攀挀漀洀洀攀渀搀攀搀 瀀爀漀挀攀搀甀爀攀⸀ 匀唀匀倀䔀一匀䤀伀一 匀夀匀吀䔀䴀 愀挀挀攀猀猀漀爀椀攀猀 猀甀瀀瀀氀椀攀搀 戀礀 䴀愀渀甀昀愀挀琀甀爀攀爀 挀漀渀猀椀猀琀椀渀最 漀昀 䴀㘀 䄀渀挀栀漀爀 䘀愀猀 teners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344- 413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).′浭挠浥湥⁴汰獡整景洠硩㨠J‵浭挠浥湥⁴汰獡整湯琠敨爠畯桧猠摩景猠湩汧牯栠污牢捩慷汬漠業ᵸ〲洠散敭瑮瀠慬瑳牥漠業⁸债㈱†浭†散敭瑮†汰獡整映湩獩敨眠瑩愠映潬瑡湩潣瑡漠敮瑡挠浥湥⁴景洠硩㨠s‵浭挠浥湥⁴汰獡整湯爠畯桧猠摩景猠湩汧牯栠污牢捩慷汬映湩獩敨楷桴愠映潬瑡湩潣瑡漠敮瑡挠浥湥⁴景洠硩¸‸†浭†挠浥湥⁴†汰獡整†湩†琠潷†挠慯獴甠摮牥氠祡牥ㄠ′浭琠楨正挠浥湥⁴汰獡整㨱‵ㄨ挠浥湥⁴›‵慳摮 楦楮桳摥眠瑩潴⁰慬敹洶桴捩散敭瑮瀠慬瑳牥ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⥤쬮㠱†洠†散敭瑮†瀠慬瑳牥†椠†睴†潣瑡湵敤慬敹㈱洠桴捩散敭瑮瀠慬瑳牥ㄠ㔺⠠‱散敭瑮㨠㔠猠湡⥤愠摮愠琠灯氠祡牥㘠浭琠楨正挠浥湥⁴汰獡整㨱″ㄨ挠浥湥⁴›″猠湡⥤映湩獩敨潲杵楷桴猠潰杮㰊‶洠挠浥湥⁴瀠慬瑳牥†景†業⁸㨠†㨱″⠠‱散敭瑮㨠㌠猠湡⥤Æ㘀洠散敭瑮瀠慬瑳牥ㄠ㌺⠠‱散敭瑮㨠㌠猠湡⥤†楦楮桳摥†楷桴†映潬瑡湩挠慯⁴漠敮瑡†散敭瑮†湡琠楨正†潣瑡†景†楌敭眠獡漠琠灯†景†慷汬桷湥†牤⁹映牯戠慥楲杮漠⹒⹃⹃猠慬獢愠摮戠慥獭팮潒杵†慣瑳†瀠慬瑳牥†甠瑰†〱†敨杩瑨愠潢敶†牧畯摮†敬敶眠瑩愠†業瑸牵漠慳摮†湡朠慲敶漠挠畲桳摥†瑳湯映潲洶†潴†ㄠ洰†潮業慮†楳敺†搠獡敨癯牥†湡椠据畬楤杮†桴映敲桳†汰獡整椠睴氠祡牥ⱳ†湵敤氠祡牥†㈱浭†散敭瑮瀠慬瑳牥†㨱‴⠠‱挠浥湥㩴†‴猠湡⥤†湡琠灯氠祡牥†ㄠ洰†散敭瑮†瀠慬瑳牥†ㄠ㌺†⠠‱散敭瑮›″慳摮 業數楷桴ㄠ┰映湩汥⁹牧畯摮摥†票牤瑡摥†楬敭†祢†潶畬敭†景挠浥湥䘠湩獩敨楷桴漠摲湩牡⁹散敭瑮댮敐扢敬†慤桳†汰獡整甠瑰ㄠ洰†敨杩瑨愠潢敶†牧畯摮†敬敶眠瑩愠†業瑸牵漠慷桳摥瀠扥汢牯挠畲桳摥猠潴敮㘠浭琠㈱㔮浭†潮業慮猠穩搠獡敨漠敶愠摮椠据畬楤杮†牦獥†汰獡整†湩†琠潷†氠祡牥湵敤慬敹㈱浭挠浥湥⁴汰獡整㨱‴ㄨ挠浥湥㩴†‴猠湡⥤†湡琠灯†慬敹ㄠ洰散敭瑮†汰獡整眠瑩挠浥湥⁴洠牯慴ㄠ㌺⠠‱挠浥湥㩴†″猠湡⥤†業數眠瑩ㄠ┰映湩汥⁹†朠潲湵敤†栠摹慲整†氠浩†戠⁹潶畬敭漠散敭瑮㬮牐癯摩湩†猠湡†映捡摥††汰獡整†甠瑰〱敭整†栠杩瑨††扡癯†朠潲湵†氠癥汥挠湯牣瑥漠戠楲正†慭潳牮⁹猠牵慦散椠睴潣瑡ⱳ戠獡潣瑡漠㌱洠桴捩湩挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮›㐠†慳摮Ⱙ挠敬牡湩琠敨†畳晲捡戠⁹挠浯楢杮†瑩†湡楦楮桳湩潣瑡漠‸浭桴捩湩挠浥湥⁴潭瑲牡†ㄠ㌺†⠠‱†散敭瑮›†″†慳摮 †湡慴楫杮漠瑵猠牵慦散朠慲湩祢洠捥慨楮慣牡慲杮浥湥⁴牯愠灰祬湩敳潣摮挠慯⁴祢洠捥慨楮慣洠慥獮†湩汣摵湩挠獯⁴漠愠汬洠瑡牥慩ⱬ氠扡畯Ⱳ愠摮吠愠摮倠椠据畬楤杮愠汬††敬摡†氠晩⁴†愠摮††捳晡潦摬湩†攠捴潣灭敬整訮硅牴映牯†牰癯摩湩愠摮†業楸杮†慷整牰潯楦杮†洠瑡牥慩†湩†挠浥湥⁴†汰獡整潷歲椠牰灯牯楴湯爠捥浯敭摮摥戠⁹桴慭畮慦瑣牵牥 瀀牥㔠‰杫挠浥湥⁴獵摥椠桴業ᑸ硅牴潦汰獡整楲杮⸳㔱ㄮf䔀瑸牥潩慷汬景栠楥桧⁴潭敲琠慨〱洠映潲牧畯摮映牯攠敶祲愠摤瑩潩慮敨杩瑨漠″牯瀠牡⁴桴牥潥ݦ㌱ㄮ⸵瘲湉整楲牯†慷汬漠栠楥桧⁴洠牯琠慨㘠†牦浯†汦潯氠癥汥†潦攠敶祲†摡楤楴湯污栠楥桧⁴景㌠洠漠慰瑲琠敨敲景B䔀瑸慲映牯瀠慬瑳牥湩湯挠物畣慬潷歲渠瑯攠捸敥楤杮㘠洠椠慲楤獵ܺ㌱ㄮ⸶湉漠敮挠慯ݴ㌱ㄮ⸶ల湉琠潷挠慯獴o䔀瑸慲†潦瀠慬瑳牥湩搠湯漠洠畯摬湩潣湲捩獥†牯†牡档瑩慲敶椠据畬楤杮†敮瑡映湩獩潴氠湩湡敬敶㩬⸳㜱ㄮ⸳㜱㈮E䔀瑸慲†潦瀠慬瑳牥湩匠桰牥捩污䜠潲湩摥挠楥楬杮汆睥湩潳晦瑩⸳㠱ㄮ匀桰牥捩污挠楥楬杮⸳㠱㈮䜀潲湩摥挠楥楬杮⸳㠱㌮䘀敬楷杮猠景楦獴ɢ圀獡敨猠潴敮†牧瑩†汰獡整漠攠瑸牥潩慷汬†景†栠楥桧⁴†灵潴†ㄠ‰†⹍†愠潢敶朠潲湵氠癥汥†湩†睴氠祡牥ⱳ†湵敤氠祡牥ㄠ洲散敭瑮瀠慬瑳牥ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⤠†畦牲睯湩琠敨†湵敤氠祡牥†楷桴猠牣瑡档湩琠潯ⱬ†灡汰楹杮†散敭瑮†汳牵祲漠琠敨†湵敤氠祡牥†⁀㈠†杋漠†散敭瑮瀠牥†猠畱牡†敭牴ⱥ†琠灯†氠祡牥†ㄠ洵散敭瑮†汰獡整ㄠㄺ㈯㈺†ㄨ†散敭瑮†›ㄠ㈯猠湡›′瑳湯档灩楰杮ㄠ洰潮業慮楳敺 湩瀠湡汥楷桴朠潲癯污牡畯摮愠数††愠灰潲敶††瀠瑡整湲†††湩汣摵湩捳畲扢湩愠摮†慷桳湩Ⱨ†桴琠灯†慬敹楷桴†牢獵敨愠摮†慷整琠攠灸獯琠敨猠潴敮†ꀠ†挠楨灰湩獧挬浯汰瑥††愠††瀠牥猠数楣楦慣楴湯愠摮搠物捥楴湯漠湅楧敮牥湩†挠慨杲†⠠慐浹湥⁴†映牯††牰癯摩湩牧潯敶桳污敢洠摡敳慰慲整祬⸩ŵ䘀牯業杮†牧潯敶†景†湵晩牯猠穩㈠‰漠㔱洠楷敤愠摮ㄠ‵浭搠敥⁰湩琠敨琠灯氠祡牥漠慷桳摥猠潴敮朠楲⁴汰獡整獡瀠牥愠灰潲敶慰瑴牥獵湩潷摯湥戠瑡整獮慮汩摥†琠†桴†湵敤†慬敹†湩汣摵湩敲潭慶景眠潯敤慢瑴湥ⱳ爠灥楡潴琠敨攠杤獥漠慰敮獬愠摮映湩獩楨杮琠敨朠潲癯潣灭敬整††獡††数†猠数楣楦慣楴湯†愠摮搠物捥楴湯漠桴湅楧敮牥椭档牡敧㨠»䔀瑸慲††潦†眠獡敨†朠楲⁴†瀠慬瑳牥††湯攠瑸牥潩⽲湩整楲牯†慷汬漠栠楥桧⁴洠牯桴湡†〱映潲朠潲湵⽤汦潯氠癥汥†潦癥牥⁹愠摤瑩潩慮栠楥桧⁴漠㌠†漠瀠牡⁴桴牥潥o䔀瑸慲†潦眠獡敨猠潴敮†牧瑩†汰獡整漠楣捲汵牡†眠牯†潮⁴†硥散摥湩†洶†椠慲楤獵⠠湩琠潷挠慯獴⸩ǘ䘀牯業杮†牧潯敶†景†湵晩牯猠穩映潲㈱ㅸ洲湡灵潴㈠砵㔱浭椠桴潴⁰慬敹†景†眠獡敨†瑳湯†牧瑩†瀠慬瑳牥摥猠牵慦散††愠††数††灡牰癯摥††瀠瑡整湲湩汣摵湩††瀠潲楶楤杮†††湡††映硩湩污浵湩浵†档湡敮獬†景†灡牰灯楲瑡猠穩湡琠楨正敮獳†渨瑯†敬獳†桴湡†′洠⥭慮汩摥琠桴湵敤慬敹楷桴爠獵⁴牰潯捳敲獷†愠摮†渠楡獬†愠摮†映湩獩楨杮†琠敨朠潲癯挠浯汰瑥愠瀠牥†灳捥晩捩瑡潩獮愠摮搠物捥楴湯漠桴湅楧敮牥椭桃牡敧礮硅牴潦獵湩桷瑩散敭瑮椠汰捡景漠摲湩牡⁹散敭瑮†湩†桴琠灯†慬敹漠琠敨椠整景眠獡敨瑳湯牧瑩瀠慬瑳牥ጮ牐癯摩湩愠摮†灡汰楹杮†㈱†浭†桴捩愨敶慲敧 牰浥硩摥映牯畭慬整湯潣瑡朠灹畳†氠杩瑨敷杩瑨††汰獡整†栠癡湩摡楤楴敶湡楬桧⁴敷杩瑨愠杧敲慧整獡瘠牥業畣楬整 †††瀠牥楬整††††敲灳捥楴敶祬挠湯潦浲湩潴䤠㩓㈠㐵‷倨牡⁴ㄭ愠摮䤠⥉ㄠ㜹ⰶ††灡汰敩†漠†栠捡敫⽤††湵癥湥戠捡杫潲湵猠捵愠戠牡戠楲正 戠潬正 䍒⁃眠牯漠眠污獬†湡挠楥楬杮†瑡†污汦潯獲†湡氠捯瑡潩獮攬捸畬楤杮†湩†慷汬眠楨档††慭⁹†挠浯†椠†挠湯慴瑣††楷桴搠浡湰獥†映湩獩敨湩猠潭瑯楬敮愠摮氠癥汥攠捴潣灭敬整央硅牴潦摡楤楴湯漠祳瑮敨楴潐祬獥整牴慩杮汵牡映扩敲漠敬杮桴㘠浭晥敦瑣癩楤浡瑥牥†ㄠⴰ〴†洠捩潲獮†愠摮†猠数楣楦牧癡瑩⁹†景†ㄠ㌮‴†潴†ㄠ㐮‰†湩†挠浥湥⁴汰獡整⽲潭瑲牡†戠⁹†獵湩†㈱朵獭†晏猠湹桴瑥捩†潐祬獥整琠楲湡畧慬映扩敲†潦〵†杋†散敭瑮†獵摥†湩†散敭瑮†潭瑲牡愠数楤敲瑣潩獮漠湅楧敮牥椭桃牡敧ᜮ数慢景㔠‰杫挠浥湥ꍴ牐癯摩湩愠摮†楦楸杮†敭桳†湩†敶瑲捩污愠摮†栠牯穩湯慴†番据楴湯†漠†䍒⁃†湡牢捩⽫䅁⁃眠牯椠据畬楤杮†捳晡潦摬湩湡污敬摡愠摮氠晩⁴瑥挠浯汰瑥ꕥ⹇⹉††挠楨正湥††洠獥††獡††瀠牥††䤠䥓猠数楣楦慣楴湯†湡椠琠敨†敲畱物摥†楷瑤楷桴†〵浭†潬杮†潂扭祡†慮汩戠晥牯汰獡整楲杮甠瑰ㄠ‰敭整敨杩瑨㌱㈮⸷ਲ倀潲楶楤杮愠摮映硩湩楦牢敭桳漠㐱‵升⁍†敷杩瑨†椠†敲畱物摥†眠摩桴†眠瑩散敭瑮†潭瑲牡†敢潦敲†汰獡整楲杮†灵潴ㄠ洰栠楥桧ਊ煓٭㐊⸵〰W′浭琠楨正瀠慬湩挠浥湥⁴潭瑲牡戠湡獤椠挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮†›㐠猠湡⥤㨠⸳㠲ㄮ 䘀畬桳䈠湡।浣瀠牥洠܊㌱㈮⸸ल畓歮䈠湡ݤ㌱㈮⸸ଳ慒獩摥䈠湡ݤ㌱㈮⸸ఴ潍汵敤慂摮U‸浭琠楨正瀠慬湩挠浥湥⁴潭瑲牡戠湡湩†散敭瑮†潭瑲牡†㨱‴⠠‱挠浥湥⁴㨠†‴慳摮㨩⸳㈠⸹࠱㌱㤲㈮⸳㈠⸹࠳㌱㤲㐮È‸洠琠楨正†潭汵敤挠浥湥⁴洠牯慴慢摮†湩†睴挠慯獴†湵敤氠祡牥†㈱浭琠楨正眠瑩散敭瑮洠牯慴㨱‵ㄨ挠浥湥⁴›㔠††慳摮 琠灯†慬敹㘠浭†桴捩眠瑩散敭瑮洠牯慴㨱⠴‱散敭瑮㨠㐠猠湡⥤儮潐湩楴杮漠牢捩潷歲漠牢捩汦潯楲杮眠瑩散敭瑮洠牯慴㨱⠳挱浥湥㩴″慳摮 ܺ㌱㌮⸱㘱汆獵† †畒敬 sqm 2775
/ Struck or weathered pointing.13.31.2Raised and cut pointing13.31.3 Sunk pointingFPointing on stone work with cement mortar 1:3 (1 cement: 3 sand).13.32.1Flush/ Ruled pointing13.32.2mRaised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3 marble dust)jPointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 sand): Flush/ Ruled pointingExtra for pointing on walls on the outside/inside at height more than 10 metre from ground/floor level for every additional height of 3 m or part there of.tProviding and fixing broken glass in cement mortar 1.3 including cost of mortar, over compound walls.Providing and fixing writing board green writing with chalk (regular modified polyster coated steel surface). of sizes.13.37.1size 1200mmx1800mm13.37.2size 1200mmx2400mm13.37.3size 1200mmx3000mmProviding and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth completePlaster of paris punning13.39.1¡Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete.13.39.2aExtra for making 12mm flute grove with6 mm depth to prepare the surface even and smooth complete.OExtra for lining out plaster to imitate stone or concrete blocks walling.µProviding and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. µ9AProviding and applying special putty in two coats based materials varnish, Belgium chalk, turpentine oil, white paint, safeda including sand papering for making the surface smooth for applying any or vinyl paints including all cost of material and labouretc complete.YWhite washing with lime to give an even shade: New work (three or more coats)Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime.(Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coat on new work.ÆWall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new workHDistempering by any mechanical or manual means with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.47.113.47.2"Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.48.113.48.2sWall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade.¿Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.èFinishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surfaceåFinishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface)ÑFinishing walls by any mechanical or manual means with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.54.1ÓPainting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture13.54.2åPainting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture.13.54.3Two or more coats applied on walls @ 1.25 ltr/10 sqm. Over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm.¸Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:13.55.1One coat13.55.2 Two coatsèFinishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution.4Applying a coat of mordant solution on G.S. sheet : 13.58.1LWith a solution of 38 gms of copper acetate in a litre of soft water 13.58.2ÎWith a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water.&Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint approved brand and manufacture over and including a priming of ready mixed zinc chromate yellow primer on new work :13.59.175 mm diameter pipes13.59.2100 mm diameter pipes13.59.3150 mm diameter pipesëPainting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work.13.60.113.60.213.60.3pPainting with oil type wood preservative of approved brand and manufacture: New work (two or more coats)ôProviding and applying two coats o f fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.$Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.13.67.1With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.13.67.2~With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre.13.67.3dWith water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work.¦Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work.Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new workBVarnishing with varnish of approved brand and manufacture:13.72.1hTwo or more coats of glue sizing with copal varnish over an under coat of flatting varnish.13.72.2aTwo or more coats glue sizing with spar varnish or an under coat of flatting varnish.]French spirit polishing: Two or more coats on new works including a coat of wood filler.nPolishing on wood work with ready mixed wax polish of approved brand and manufacture: New work.Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler.jFloor polishing on masonry or concrete floors with wax polish of approved brand and manufacture.MLettering with black Japan paint of approved brand and manufacture.per letter per cm heightEProviding and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on sqm 2675
k extruded polystyrene rigid insulation board (XPS) of required size over outer wall surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM and Fire retardant property as per DIN 4102, Part 1. XPS insulation of thickness 50mm shall be placed over brushed, algae free and levelled external wall by connecting the ship-laps joints and fixed by the washer and Self-Tapping Screw of suitable length at each corner and at distance 75mm from the edge and bitumen shall be applied over the joints and G.I. Expanded Mesh (Barfi Jali) shall be fixed over XPS board by a Self- Tapping Screw of suitable length at the centre of the board and 15mm PCC shall be applied over the board (paint of suitable choice can be used), all as per the directions of Engineer-in-Charge. &Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorption < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. pPainting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats)Scrapping/sand papering of existing surface with the help of mechanized sanding machine (having mechanical vaccum machine with bag for dust collection to make surface even and smooth) as per direction of Engineer-in- Charge.Providing and applying 1 coat of Triple booster primer-resist dampness, efflorescence, alkali & at the same time improve top coat coverage by 15-20% @1.0 lt/ 10 sqm, which confirms certfication of IS 109/1968. It can be applied by Brush/ Spray Machine and the work shall be carried out as per secification& the direction of the Engineer-in-Charge.ÃFinishing walls with water based anti- germ paint of with VOC < 50 g/l, that kills disease causing germs, teflon based washability and Anti fungal properties in two or more coats @ 1.08 ltr / 10 sqm over priming coat of interior primer applied @ 1.08 ltr / 10 sqm of required shade including removing of all dust complete as per direction of Engineer- in-Charge and submission of challans of materials on enquiry. /Providing and applying in two coats of 250 micron thick each layer of epoxy coating on prepared surface (cost includes preparing the plastered surface smooth ready to receive epoxy coating) for operation theater walls in desired colour as per direction of Engineer-in-Charge ZIndian ethnic art painting such as tribal Art Pithora or warli/Gond or Bhil Painting on any wall surface ( interior or exterior) by using textured/smooth exterior/interior paint of approved brand or Manufacturer including preparation of surface and cost of all material labour and scaffolding etc. complete as per direction of Engineer-in-charge.Exposed Concrete is composed of a mix natural and mix elements portland cement, hardest earthen material, special additives, natural grains and special polymers to create external beauty, aesthetic value and heritage effects of concrete. thickness 4mm to 6mm.(payment for providing grooves shall be made separately)First coat:- Base coat Apply of Cementous ready mix coarse dark grey color material for making of groove, applied on smooth plaster surface with the thickness of 0.75mm to 1.5mm by trowel Second coat:-Apply of Cementous ready mix fine material, applied on plaster surface with the thickness of 2mm to 3mm by trowel. with or with out groves as per requirement and with 6mm groves (if grooves requires) with masking top of dark grey colour as per approved sample, for the complete satisfaction of architect/Engineer in charge. Third coat :- Protective clear top coat sealer (water based) applied by roller/sponge.Applying two coats of sealer (special silicate water based water repellent protector) with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs on exterior stone façade and stone jali.At an approximate coverage of 50 to 70 Sq.f./Ltr.½Providing and applying plaster of Paris punning of 12 mm average thickness over plastered surface including 12mm flute grove with 6 mm depth to prepare the surface even and smooth complete.ÍExtra rate in internal plastering work for every additional floors above ground floor (due to lifting of material, ,scaffolding and labour etc. complete)Note:- Applicable to item No. 13.1 to item No. 13.10ñProviding and fixing of roller blinds / vertical blinds of washable fabric duly fixed with powder coated aluminum channel and clamps having nylon rope for manual operation of approved colour and company as per director by Engineer-In-Charge.¦Providing and fixing of Wallpaper of approved design, colour, pattern, as per direction of Engineer-In-Charge including all material, labour, fixing and installation.13.105.1%Standard pattern and design wallpaper13.105.23D pattern and design wallpaper13.105.3Customize design wallpaperRepairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out ¼joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand).ñFixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meters lead :14.2.1Door chowkhats14.2.2Window chowkhats14.2.3Clerestory window chowkhatsFixing chowkhat in existing opening in brick / RCC wall with dash fasteners/ chemical fastener of appropriate size (3nos on each vertical member of door chowkhat and 2 nos. on each vertical member of window chowkhats) including cost of dash fasteners/ chemical fastener."Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish as directed by Engineer- in-charge. For door/ window/ clerestory window.bRenewing glass panes, with putty and nails wherever necessary including racking out the old putty:14.5.1#Float glass panes of thickness 4 mm14.5.2%Float glass panes of thickness 5.5 mm@Renewing glass panes with now wooden fillets wherever necessary:14.6.114.6.2:Renewing glass panes and refixing existing wooden fillets:14.7.114.7.2;Supplying and fixing new wooden fillets wherever necessary:14.8.12nd class teak wood fillets14.8.2Haldu/Bija/Kail wood fillets.-Renewal of old putty of glass panes (length)..Refixing old glass panes with putty and nails.GFixing old glass panes with wooden fillets (excluding cost of fillets).-Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed port suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre tocentre, and cross “T” of size 24x28mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mmpanel to from grid of size 600x600 mm, resting on periphery walls/ partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000Ӟ洁洀 洀愀搀攀 漀昀 ⸀㐀 洀洀 琀栀椀挀欀 ⠀洀椀渀椀洀甀洀⤀ 猀栀攀攀琀 眀椀琀栀 琀栀攀 栀攀氀瀀 漀昀 爀愀眀氀瀀氀甀最猀 愀琀 㐀㔀 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 眀椀琀栀 ㈀㔀 洀洀 氀漀渀最 搀爀礀 眀愀氀氀 猀挀爀攀眀猀 䀀 ㈀㌀ 洀洀 椀渀琀攀爀瘀愀氀 愀渀搀 氀愀礀椀渀最 㔀 洀洀 琀栀椀挀欀 搀攀渀猀椀昀椀攀搀 攀搀最攀猀 ㌀㠀㠀愀氀瘀愀渀椀 猀椀氀椀挀愀琀攀 挀攀椀氀椀渀最 琀椀氀攀猀 漀昀 愀瀀瀀爀漀瘀攀搀 琀攀砀琀甀爀攀 椀渀 琀栀攀 最爀椀搀Ⰰ 椀渀挀氀甀搀椀渀最Ⰰ 挀甀琀琀椀渀最⼀ 洀愀欀椀渀最 漀瀀攀渀椀渀最 昀漀爀 猀攀爀瘀椀挀攀猀 氀椀欀攀 搀椀昀昀甀猀攀爀猀Ⰰ 最爀椀氀氀猀Ⰰ 氀椀最栀琀 昀椀琀琀椀渀最猀Ⰰ 昀椀砀琀甀爀攀猀Ⰰ 猀洀漀欀攀 搀攀琀攀挀琀漀爀猀 攀琀挀⸀Ⰰ 眀栀攀爀攀瘀攀爀 爀攀焀甀椀爀攀搀⸀䴀愀椀渀 ᠀吠ᤀ†爀甀渀渀攀爀猀 琀漀 戀攀 猀甀猀瀀攀渀搀攀搀 昀爀漀洀 挀攀椀氀椀渀最 甀猀椀渀最 䜀⸀䤀⸀ 猀氀漀琀琀攀搀 挀氀攀愀琀猀 漀昀 猀椀稀攀 ㈀㔀砀㌀㔀砀⸀㘀 洀洀 昀椀砀攀搀 琀漀 挀攀椀氀椀渀最 眀椀琀栀 ㈀⸀㔀 洀洀 搀椀愀 愀渀搀 㔀 洀洀 氀漀渀最搀愀猀栀 昀愀猀琀攀渀攀爀猀Ⰰ 㐀 洀洀 䜀⸀䤀⸀ 愀搀樀甀猀琀愀戀氀攀 爀漀搀猀 眀椀琀栀 ㌀㠀㠀愀氀瘀愀渀椀稀攀搀 猀琀攀攀氀 氀攀瘀攀氀挀氀椀瀀猀 漀昀 猀椀稀攀 㠀㔀 砀 ㌀ 砀 ⸀㠀 洀洀Ⰰ 猀瀀愀挀攀搀 愀琀 ㈀ 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 愀氀漀渀最 洀愀椀渀 ᠀吠ᤀⰠ 戀漀琀琀漀洀 攀砀瀀漀猀攀搀 眀椀琀栀 ㈀㐀 洀洀漀昀 愀氀氀 吀猀攀挀琀椀漀渀猀 猀栀愀氀氀 戀攀 瀀爀攀ⴀ 瀀愀椀渀琀攀搀眀椀琀栀 瀀漀氀礀猀琀攀爀 戀愀欀攀搀 瀀愀椀渀琀Ⰰ 昀漀爀 愀氀氀 栀攀椀最栀琀猀Ⰰ 愀猀 瀀攀爀 猀瀀攀挀椀昀椀挀愀琀椀漀渀猀Ⰰ 搀爀愀眀椀渀最猀 愀渀搀 愀猀 搀椀爀攀挀琀攀搀 戀礀 䔀渀最椀渀攀攀爀ⴀ 椀渀ⴀ䌀栀愀爀最攀⸀一漀琀攀 㨀ⴀ 伀渀氀礀 挀愀氀挀椀甀洀 猀椀氀椀挀愀琀攀 昀愀氀猀攀 挀攀椀氀椀渀最 愀爀攀愀 眀椀氀氀 戀攀 洀攀愀猀甀爀攀搀 昀爀漀洀 眀愀氀氀 琀漀 眀愀氀氀⸀ 一漀 搀攀搀甀挀琀椀漀渀 猀栀愀氀氀 戀攀 洀愀搀攀 昀漀爀 攀砀瀀漀猀攀搀 昀爀愀洀攀猀⼀ 漀瀀攀渀椀渀最 ⠀挀甀琀 漀甀琀猀⤀ 栀愀瘀椀渀最 愀爀攀愀 氀攀猀猀 琀栀愀渀 ⸀㌀ 猀焀洀⸀吀栀攀 挀愀氀挀椀甀洀 猀椀氀椀挀愀琀攀 挀攀椀氀椀渀最 琀椀氀攀 猀栀愀氀氀 栀愀瘀攀 一刀䌀 瘀愀氀甀攀 漀昀 ⸀㔀 ⠀䴀椀渀椀洀甀洀⤀Ⰰ 氀椀最栀琀 爀攀昀氀攀挀琀椀漀渀 㸀 㠀㔀─Ⰰ 渀漀渀ⴀ 挀漀洀戀甀猀琀椀戀氀攀 愀猀 瀀攀爀 䈀⸀匀⸀ 㐀㜀㘀 瀀愀爀琀 䤀嘀Ⰰ ─ 栀甀洀椀搀椀琀礀 爀攀猀椀猀琀愀渀挀攀 愀渀搀 愀氀猀漀 栀愀瘀椀渀最 琀栀攀爀洀愀氀 挀漀渀搀甀挀琀椀瘀椀琀礀᐀牐癯摩湩湡楦楸杮甠癰汰湡Ⱬ倠慬歮猠穩㌨〴堠㈠〷‰ 浭愠数灡牰癯摥猠慨敤桴慰敮桳污敢氠獡牥挠瑡整湥景瀠慬歮映硩湩牴浩映硩摥愠摮挠牯敮摥敧漠散汩湩楦數⁵癰汣灩猠浡潣潬牵愠摮瀠潲楶楤杮愠摮映硩湩景映慲敭眠牯慭敤漠灳捥慩敳瑣潩獮潰敷牰獥敳牦浯䴠匮桳敥獴愠摮朠污慶楮敺楷桴稠湩潣瑡湩景ㄠ㔲朠獭猯浱⠠潢桴猠摩湩汣獵癩⥥愠数卉㨠㈠㜷愠摮挠湯楳瑳湩景愠杮敬挠敬瑡景猠穩㔲洠楷敤砠ㄠ㘮洠桴捩楷桴映慬杮獥漠㜲洠湡㜳浭瑡ㄠ〲‰浭挠湥牴潴挠湥牴ⱥ漠敮映慬杮楦數潴ʗ琀敨挠楥楬杮眠瑩慤桳映獡整敮㈱㔮洠楤⁸〵浭氠湯楷桴㘠浭搠慩戠汯獴漬桴牥映慬杮景挠敬瑡映硩摥琠桴湡汧慨杮牥景㈠砵〱へ㔮‰浭漠敲畱物摥氠湥瑧楷桴渠瑵…潢瑬景爠煥極敲楳敺愠摮漠桴牥攠摮漠湡汧慨杮牥映硩摥眠瑩湩整浲摥慩整䜠䤮档湡敮獬㐠砵㔱へ㤮洠畲湮湩瑡琠敨猠慰楣杮漠㈱〰洠散瑮敲琠散瑮敲潴眠楨档琠敨挠楥楬杮猠捥楴湯〠㔮洠桴捩潢瑴浯眠摥敧漠〸洠楷桴琠灡牥摥映慬杮獥漠㘲洠慥档栠癡湩楬獰漠〱㔮洠Ɑ愠⁴㔴‰浭挠湥牴潴挠湥牴ⱥ猠慨汬戠楦數湩愠搠物捥楴湯瀠牥数摮捩汵牡樬琠楲湥汣灩椠据畬敤湩琠楨瑩浥愠祮漠桴牥椠整潮⁴敢瀠楡敳牰瑡祬挠浯汰瑥湩愠汬爠獥数瑣愠数桴楤敲瑣潩獮漠湅楧敮牥椭桃牡敧Μ倁爀漀瘀椀搀椀渀最 ☀ 䘀椀砀椀渀最 倀嘀䌀 挀攀椀氀椀渀最猀礀猀琀攀洀 瀀爀漀昀椀氀攀 瀀愀渀攀氀 眀椀琀栀 挀氀椀挀欀 猀礀猀琀攀洀椀渀琀攀爀氀漀挀欀 瀀愀渀攀氀 猀椀稀攀 㐀 洀洀砀㌀㐀 洀洀砀洀洀 爀攀猀椀猀琀愀渀挀攀 琀漀 眀攀愀琀栀攀爀 瀀攀爀昀攀挀琀 昀椀渀椀猀栀 椀渀 眀漀漀搀 最爀愀椀渀 ☀ 猀漀氀椀搀 挀漀氀漀甀爀 洀愀椀渀琀攀渀愀渀挀攀 昀爀攀攀 刀攀猀椀猀琀愀渀挀攀 琀漀 眀攀愀琀栀攀爀 琀爀甀氀礀 愀渀琀椀 戀愀挀琀攀爀椀愀氀⸀ 眀椀琀栀 攀搀最攀 瀀爀漀昀椀氀攀 䨀ⴀ琀爀椀洀 漀渀 瀀攀爀椀瀀栀攀爀礀 ☀ 挀攀渀琀攀爀 瀀爀漀昀椀氀攀 吀ⴀ琀爀椀洀 椀渀 瀀愀渀攀氀 樀漀椀渀琀 䌀漀洀瀀氀攀琀攀 匀礀猀琀攀洀 琀漀 戀攀 昀椀砀攀搀 漀渀 䜀⸀䤀⸀ 昀爀愀洀攀眀漀爀欀 漀昀 挀攀椀氀椀渀最猀攀挀琀椀漀渀 愀琀 㐀㔀 洀洀 搀椀猀琀愀渀挀攀 眀椀琀栀 攀渀琀攀爀 猀攀挀琀椀漀渀 猀甀猀瀀攀渀搀攀搀 戀礀 爀漀漀昀 戀礀 䜀⸀䤀⸀ 愀渀最氀攀 栀愀渀最攀爀 椀渀 瀀爀漀瀀攀爀 氀椀渀攀 ☀ 氀攀瘀攀氀 攀琀挀 挀漀洀瀀氀攀琀攀 倀刀伀䐀唀䌀吀 倀䔀䌀䤀䘀䤀䌀䄀吀䤀伀一匀㨀䴀攀攀琀猀 漀爀 攀砀挀攀攀搀猀 琀栀攀 猀琀愀渀搀愀爀搀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 漀昀 ⠀䄀匀吀䴀 䐀ⴀ㐀㐀㜀㜀⤀ 愀渀搀 椀琀猀 爀攀昀攀爀攀渀挀攀搀 搀漀挀甀洀攀渀琀猀⸀ 䤀洀瀀愀挀琀 爀攀猀椀猀琀愀渀挀攀㨀 一漀 搀攀昀漀爀洀愀琀椀漀渀漀戀猀攀爀瘀攀搀⸀ ⠀吀攀猀琀攀搀 愀琀 㔀 䰀䈀匀⤀ 吀攀渀猀椀氀攀 猀琀爀攀渀最琀栀Ⰰ 䴀倀愀㨀 㸀㌀㜀⸀ 吀攀渀猀椀氀攀 洀漀搀甀氀甀猀Ⰰ 䴀倀愀㨀 㸀㈀ 匀甀爀昀愀挀攀 搀椀猀琀漀爀琀椀漀渀㨀 一漀渀攀 愀琀 ㈀ 䘀 匀焀甀愀爀攀渀攀猀猀㨀 㰀⼀㠀ᴀ†漀昀 猀焀甀愀爀攀䰀攀渀最琀栀㨀 圀椀琀栀椀渀 밀ᴀ†漀昀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 䰀漀挀欀 挀漀渀琀爀漀氀㨀 䌀漀洀瀀氀椀攀猀 䌀漀氀漀爀 䌀栀愀渀最攀㨀 㰀㈀ 最爀愀礀猀挀愀氀攀猀 ⠀㘀 栀爀猀 甀渀搀攀爀 ㈀ 圀⼀洀㈀ 唀嘀 爀愀搀椀愀琀椀漀渀 愀琀 㔀 搀攀最爀攀攀猀⤀ 需ĄProviding & Fixing of Mineral Fibre 1200x300mm (Nominal Size) tiles Acoustical Suspended Ceiling System with 16mm thick Beveled Tegular Edge Tiles and 15mm Bolt Slot Exposed Grid. The tiles shall have fissured visual with acoustical punctures, Humidity Resistance (RH) of 99%, NRC 0.6 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C- 423 standard, CAC of 35db as per ASTM E1414, Light Reflectance 87% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 0/7 and Class A as per ASTM E84 with 16mm Beveled Tegular edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building sqm 2575
426 9.215 ion of the clamps complete.èReplacing sand stone slabs in roofing laid in cement mortar 1:4 (1 cement : 4 sand) including necessary repairs and cement pointing with same mortar complete including disposal of rubbish to dumping ground within 50 metres of lead :14.13.1.Red/ white sand stone slabs 30 to 50 mm thick.íRenewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead :14.14.1Sal wood battens.ëRenewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead :14.15.1$Not exceeding 4.00 metres in length. 14.15.1.1Sal wood beams 14.15.1.214.15.2.Above 4.00 metres and upto 5.00 metres length. 14.15.2.1 14.15.2.2¯Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground within 50 metres lead.Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking.òFixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand.¹Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer.³Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete.14.20.1Wheel 50 mm dia. and below. per wheel14.20.2Wheel above 50 mm dia.=Providing and fixing 25 mm thick shutters for cupboard etc. :14.21.1 14.21.1.1iSuperior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.1.2dIst class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws.14.21.2 14.21.2.1 14.21.2.2øProviding and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10mm laths placed 35mm apart (frames to be paid separately) including fixing 50x12mm beading complete with:14.22.114.22.2Hard wood, finger jointed¡Providing and fixing curtain rods of 1.25mm thick brass plates with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.14.23.120 mm diameter.14.23.225 mm diameter.Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.Providing joists (karries) including hoisting fixing in position and applying wood preservative on unexposed surface etc. complete with:14.25.114.25.2Haldu/Bija/Kail wood.8White washing with lime old work to give an even shade :14.26.1two or more coats14.26.2one or more coatsRemoving white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: Old work (one or more coats).ÂRemoving dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Old work (one or more coats).Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work :14.32.114.32.214.32.3Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with aluminium paint of approved brand and manufacture on old work :14.33.114.33.214.33.3³Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work :14.34.114.34.214.34.3hPainting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats)Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work.Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work.Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work.Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: One or more coats on old work.7French spirit polishing: One or more coats on old work.ÙMealamine polishing on wood work by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying Mealamine polish with air compressor. One or more coats on old work.´Lacquer polishing on wood work by preparing the surface applying putty base course. prepare the surface smooth by sand papering and then applying Lacquer polish with air compressor14.43.1One or more coats on old work.TPolishing on wood work with readymade wax polish of approved brand and manufacture :14.44.1Old workFRe-lettering with black Japan paint of approved brand and manufacture.lPainting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.WProviding and fixing C.P. brass chain and rubber plug complete for sink or wash basin :14.47.1 32 mm dia14.47.2 40 mm diaÎDistempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. As per manufacturer's specification. One or more coats on old work.@Finishing walls with textured exterior paint of required shade :14.50.1WOld work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm.14.50.27Old work (One or more coats) applied @ 1.82 ltr/10 sqm.FFinishing walls with Acrylic Smooth exterior paint of required shade :14.51.1YOld work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).14.51.26Old work (One or more coat applied @ 0.90 ltr/10 sqm).dFinishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade14.52.1[Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface.14.52.27Old work (one or more coats applied @ 0.83 ltr/10 sqm). Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :14.53.15One or more coats applied on walls @ 0.85 ltr/10 sqm.14.53.2oPainting wood work with Deluxe Multi Surface Paint of required shade. One or more coat applied @0.70 ltr/10 sqm14.53.3uPainting Steel work with Deluxe Multi Surface Paint to give an even shade. One or more coat applied @0.70 ltr/10 sqm.:Varnishing with varnish of approved brand and manufacture:14.54.1%One or more coats with copal varnish.14.54.2$One or more coats with spar varnish.<Melamine polishing on wood work (one or more coat). Old workaVarnishing with flatting varnish of approved brand and manufacture one or more coats on old work.Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade. One or more coat on old work.%40 mm thick s
tone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. Red sand stone / White sand stone) stone to be supplied by the department.14.58.1Rough chiseled dressed stone14.58.2Fine dressed stoneCoursed rubble masonry (second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 sand) (Stone shall be supplied by the department)_Laying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand) including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5mm) including making drainage opening wherever required etc. complete as per direction of Engineer-in- charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost)./Colour washing with lime to give an even shade:14.62.1(one or more coats)14.62.2(two or more coats)äConducting adequate no's. of scanning to detect the steel reinforcement in existing RCC elements by using ground/ Wall penetrating radar system to avoid the cutting of Main bars during drilling for inserting bolts etc. complete.Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge.Rebaring ofTM bars bydrilling hole &embedding bars of different diameter using epoxy grouting compound including all tools and tackles complete14.70.18 mm dia bar 10 mm dia hole Per 100 mm14.70.210 mm dia bar 12 mm dia hole14.70.312 mm dia bar 16 mm dia hole14.70.416 mm dia bar 20 mm dia hole14.70.520 mm dia bar 25 mm dia hole14.70.625 mm dia bar 32 mm dia hole14.70.732 mm dia bar 40 mm dia holeqProviding and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete.14.71.114.71.214.71.314.71.414.71.5Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete.PRepair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of f tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in- Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)litre¦Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer- incharge.¢Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge14.76.175mm average thikness14.76.250mm average thikness14.76.325mm averge thiknesspCleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.14.77.1Bars upto 12 mm diameter14.77.2Bars above 12 mm diameterSBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approvedProviding, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment underthis item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2)12 mm average thickness$25 mm average thickness in 2 layers.$50 mm average thickness in 3 layers.gProviding and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)ãCleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.&Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants !as approved by Engineer-incharge.Demolishing lime concrete manually/by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-Charge.Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge.BNominal concrete 1:3:6 or richer mix (i/c equivalent design mix).BNominal concrete 1:4:8 or leaner mix (i/c equivalent design mix).¼Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.½Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. work (Payment shall be made on the cross sectional area of R.C.C. work) as per direction of Engineer-in- Charge.OExtra for scrapping, cleaning and straightening reinforcement from R.C.C. work.ÅDemolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.15.6.1&In lime mortar with old mughal bricks.15.6.2In lime mortar.15.6.3In cement mortar.Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) :15.7.1From brick work in lime mortar.1000 nos15.7.2!From brick work in cement mortar.ÏDemolishing stone rubble masonry teners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344- 413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).′浭挠浥湥⁴汰獡整景洠硩㨠J‵浭挠浥湥⁴汰獡整湯琠敨爠畯桧猠摩景猠湩汧牯栠污牢捩慷汬漠業ᵸ〲洠散敭瑮瀠慬瑳牥漠業⁸债㈱†浭†散敭瑮†汰獡整映湩獩敨眠瑩愠映潬瑡湩潣瑡漠敮瑡挠浥湥⁴景洠硩㨠s‵浭挠浥湥⁴汰獡整湯爠畯桧猠摩景猠湩汧牯栠污牢捩慷汬映湩獩敨楷桴愠映潬瑡湩潣瑡漠敮瑡挠浥湥⁴景洠硩¸‸†浭†挠浥湥⁴†汰獡整†湩†琠潷†挠慯獴甠摮牥氠祡牥ㄠ′浭琠楨正挠浥湥⁴汰獡整㨱‵ㄨ挠浥湥⁴›‵慳摮 楦楮桳摥眠瑩潴⁰慬敹洶桴捩散敭瑮瀠慬瑳牥ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⥤쬮㠱†洠†散敭瑮†瀠慬瑳牥†椠†睴†潣瑡湵敤慬敹㈱洠桴捩散敭瑮瀠慬瑳牥ㄠ㔺⠠‱散敭瑮㨠㔠猠湡⥤愠摮愠琠灯氠祡牥㘠浭琠楨正挠浥湥⁴汰獡整㨱″ㄨ挠浥湥⁴›″猠湡⥤映湩獩敨潲杵楷桴猠潰杮㰊‶洠挠浥湥⁴瀠慬瑳牥†景†業⁸㨠†㨱″⠠‱散敭瑮㨠㌠猠湡⥤Æ㘀洠散敭瑮瀠慬瑳牥ㄠ㌺⠠‱散敭瑮㨠㌠猠湡⥤†楦楮桳摥†楷桴†映潬瑡湩挠慯⁴漠敮瑡†散敭瑮†湡琠楨正†潣瑡†景†楌敭眠獡漠琠灯†景†慷汬桷湥†牤⁹映牯戠慥楲杮漠⹒⹃⹃猠慬獢愠摮戠慥獭팮潒杵†慣瑳†瀠慬瑳牥†甠瑰†〱†敨杩瑨愠潢敶†牧畯摮†敬敶眠瑩愠†業瑸牵漠慳摮†湡朠慲敶漠挠畲桳摥†瑳湯映潲洶†潴†ㄠ洰†潮業慮†楳敺†搠獡敨癯牥†湡椠据畬楤杮†桴映敲桳†汰獡整椠睴氠祡牥ⱳ†湵敤氠祡牥†㈱浭†散敭瑮瀠慬瑳牥†㨱‴⠠‱挠浥湥㩴†‴猠湡⥤†湡琠灯氠祡牥†ㄠ洰†散敭瑮†瀠慬瑳牥†ㄠ㌺†⠠‱散敭瑮›″慳摮 業數楷桴ㄠ┰映湩汥⁹牧畯摮摥†票牤瑡摥†楬敭†祢†潶畬敭†景挠浥湥䘠湩獩敨楷桴漠摲湩牡⁹散敭瑮댮敐扢敬†慤桳†汰獡整甠瑰ㄠ洰†敨杩瑨愠潢敶†牧畯摮†敬敶眠瑩愠†業瑸牵漠慷桳摥瀠扥汢牯挠畲桳摥猠潴敮㘠浭琠㈱㔮浭†潮業慮猠穩搠獡敨漠敶愠摮椠据畬楤杮†牦獥†汰獡整†湩†琠潷†氠祡牥湵敤慬敹㈱浭挠浥湥⁴汰獡整㨱‴ㄨ挠浥湥㩴†‴猠湡⥤†湡琠灯†慬敹ㄠ洰散敭瑮†汰獡整眠瑩挠浥湥⁴洠牯慴ㄠ㌺⠠‱挠浥湥㩴†″猠湡⥤†業數眠瑩ㄠ┰映湩汥⁹†朠潲湵敤†栠摹慲整†氠浩†戠⁹潶畬敭漠散敭瑮㬮牐癯摩湩†猠湡†映捡摥††汰獡整†甠瑰〱敭整†栠杩瑨††扡癯†朠潲湵†氠癥汥挠湯牣瑥漠戠楲正†慭潳牮⁹猠牵慦散椠睴潣瑡ⱳ戠獡潣瑡漠㌱洠桴捩湩挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮›㐠†慳摮Ⱙ挠敬牡湩琠敨†畳晲捡戠⁹挠浯楢杮†瑩†湡楦楮桳湩潣瑡漠‸浭桴捩湩挠浥湥⁴潭瑲牡†ㄠ㌺†⠠‱†散敭瑮›†″†慳摮 †湡慴楫杮漠瑵猠牵慦散朠慲湩祢洠捥慨楮慣牡慲杮浥湥⁴牯愠灰祬湩敳潣摮挠慯⁴祢洠捥慨楮慣洠慥獮†湩汣摵湩挠獯⁴漠愠汬洠瑡牥慩ⱬ氠扡畯Ⱳ愠摮吠愠摮倠椠据畬楤杮愠汬††敬摡†氠晩⁴†愠摮††捳晡潦摬湩†攠捴潣灭敬整訮硅牴映牯†牰癯摩湩愠摮†業楸杮†慷整牰潯楦杮†洠瑡牥慩†湩†挠浥湥⁴†汰獡整潷歲椠牰灯牯楴湯爠捥浯敭摮摥戠⁹桴慭畮慦瑣牵牥 瀀牥㔠‰杫挠浥湥⁴獵摥椠桴業ᑸ硅牴潦汰獡整楲杮⸳㔱ㄮf䔀瑸牥潩慷汬景栠楥桧⁴潭敲琠慨〱洠映潲牧畯摮映牯攠敶祲愠摤瑩潩慮敨杩瑨漠″牯瀠牡⁴桴牥潥ݦ㌱ㄮ⸵瘲湉整楲牯†慷汬漠栠楥桧⁴洠牯琠慨㘠†牦浯†汦潯氠癥汥†潦攠敶祲†摡楤楴湯污栠楥桧⁴景㌠洠漠慰瑲琠敨敲景B䔀瑸慲映牯瀠慬瑳牥湩湯挠物畣慬潷歲渠瑯攠捸敥楤杮㘠洠椠慲楤獵ܺ㌱ㄮ⸶湉漠敮挠慯ݴ㌱ㄮ⸶ల湉琠潷挠慯獴o䔀瑸慲†潦瀠慬瑳牥湩搠湯漠洠畯摬湩潣湲捩獥†牯†牡档瑩慲敶椠据畬楤杮†敮瑡映湩獩潴氠湩湡敬敶㩬⸳㜱ㄮ⸳㜱㈮E䔀瑸慲†潦瀠慬瑳牥湩匠桰牥捩污䜠潲湩摥挠楥楬杮汆睥湩潳晦瑩⸳㠱ㄮ匀桰牥捩污挠楥楬杮⸳㠱㈮䜀潲湩摥挠楥楬杮⸳㠱㌮䘀敬楷杮猠景楦獴ɢ圀獡敨猠潴敮†牧瑩†汰獡整漠攠瑸牥潩慷汬†景†栠楥桧⁴†灵潴†ㄠ‰†⹍†愠潢敶朠潲湵氠癥汥†湩†睴氠祡牥ⱳ†湵敤氠祡牥ㄠ洲散敭瑮瀠慬瑳牥ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⤠†畦牲睯湩琠敨†湵敤氠祡牥†楷桴猠牣瑡档湩琠潯ⱬ†灡汰楹杮†散敭瑮†汳牵祲漠琠敨†湵敤氠祡牥†⁀㈠†杋漠†散敭瑮瀠牥†猠畱牡†敭牴ⱥ†琠灯†氠祡牥†ㄠ洵散敭瑮†汰獡整ㄠㄺ㈯㈺†ㄨ†散敭瑮†›ㄠ㈯猠湡›′瑳湯档灩楰杮ㄠ洰潮業慮楳敺 湩瀠湡汥楷桴朠潲癯污牡畯摮愠数††愠灰潲敶††瀠瑡整湲†††湩汣摵湩捳畲扢湩愠摮†慷桳湩Ⱨ†桴琠灯†慬敹楷桴†牢獵敨愠摮†慷整琠攠灸獯琠敨猠潴敮†ꀠ†挠楨灰湩獧挬浯汰瑥††愠††瀠牥猠数楣楦慣楴湯愠摮搠物捥楴湯漠湅楧敮牥湩†挠慨杲†⠠慐浹湥⁴†映牯††牰癯摩湩牧潯敶桳污敢洠摡敳慰慲整祬⸩ŵ䘀牯業杮†牧潯敶†景†湵晩牯猠穩㈠‰漠㔱洠楷敤愠摮ㄠ‵浭搠敥⁰湩琠敨琠灯氠祡牥漠慷桳摥猠潴敮朠楲⁴汰獡整獡瀠牥愠灰潲敶慰瑴牥獵湩潷摯湥戠瑡整獮慮汩摥†琠†桴†湵敤†慬敹†湩汣摵湩敲潭慶景眠潯敤慢瑴湥ⱳ爠灥楡潴琠敨攠杤獥漠慰敮獬愠摮映湩獩楨杮琠敨朠潲癯潣灭敬整††獡††数†猠数楣楦慣楴湯†愠摮搠物捥楴湯漠桴湅楧敮牥椭档牡敧㨠»䔀瑸慲††潦†眠獡敨†朠楲⁴†瀠慬瑳牥††湯攠瑸牥潩⽲湩整楲牯†慷汬漠栠楥桧⁴洠牯桴湡†〱映潲朠潲湵⽤汦潯氠癥汥†潦癥牥⁹愠摤瑩潩慮栠楥桧⁴漠㌠†漠瀠牡⁴桴牥潥o䔀瑸慲†潦眠獡敨猠潴敮†牧瑩†汰獡整漠楣捲汵牡†眠牯†潮⁴†硥散摥湩†洶†椠慲楤獵⠠湩琠潷挠慯獴⸩ǘ䘀牯業杮†牧潯敶†景†湵晩牯猠穩映潲㈱ㅸ洲湡灵潴㈠砵㔱浭椠桴潴⁰慬敹†景†眠獡敨†瑳湯†牧瑩†瀠慬瑳牥摥猠牵慦散††愠††数††灡牰癯摥††瀠瑡整湲湩汣摵湩††瀠潲楶楤杮†††湡††映硩湩污浵湩浵†档湡敮獬†景†灡牰灯楲瑡猠穩湡琠楨正敮獳†渨瑯†敬獳†桴湡†′洠⥭慮汩摥琠桴湵敤慬敹楷桴爠獵⁴牰潯捳敲獷†愠摮†渠楡獬†愠摮†映湩獩楨杮†琠敨朠潲癯挠浯汰瑥愠瀠牥†灳捥晩捩瑡潩獮愠摮搠物捥楴湯漠桴湅楧敮牥椭桃牡敧礮硅牴潦獵湩桷瑩散敭瑮椠汰捡景漠摲湩牡⁹散敭瑮†湩†桴琠灯†慬敹漠琠敨椠整景眠獡敨瑳湯牧瑩瀠慬瑳牥ጮ牐癯摩湩愠摮†灡汰楹杮†㈱†浭†桴捩愨敶慲敧 牰浥硩摥映牯畭慬整湯潣瑡朠灹畳†氠杩瑨敷杩瑨††汰獡整†栠癡湩摡楤楴敶湡楬桧⁴敷杩瑨愠杧敲慧整獡瘠牥業畣楬整 †††瀠牥楬整††††敲灳捥楴敶祬挠湯潦浲湩潴䤠㩓㈠㐵‷倨牡⁴ㄭ愠摮䤠⥉ㄠ㜹ⰶ††灡汰敩†漠†栠捡敫⽤††湵癥湥戠捡杫潲湵猠捵愠戠牡戠楲正 戠潬正 䍒⁃眠牯漠眠污獬†湡挠楥楬杮†瑡†污汦潯獲†湡氠捯瑡潩獮攬捸畬楤杮†湩†慷汬眠楨档††慭⁹†挠浯†椠†挠湯慴瑣††楷桴搠浡湰獥†映湩獩敨湩猠潭瑯楬敮愠摮氠癥汥攠捴潣灭敬整央硅牴潦摡楤楴湯漠祳瑮敨楴潐祬獥整牴慩杮汵牡映扩敲漠敬杮桴㘠浭晥敦瑣癩楤浡瑥牥†ㄠⴰ〴†洠捩潲獮†愠摮†猠数楣楦牧癡瑩⁹†景†ㄠ㌮‴†潴†ㄠ㐮‰†湩†挠浥湥⁴汰獡整⽲潭瑲牡†戠⁹†獵湩†㈱朵獭†晏猠湹桴瑥捩†潐祬獥整琠楲湡畧慬映扩敲†潦〵†杋†散敭瑮†獵摥†湩†散敭瑮†潭瑲牡愠数楤敲瑣潩獮漠湅楧敮牥椭桃牡敧ᜮ数慢景㔠‰杫挠浥湥ꍴ牐癯摩湩愠摮†楦楸杮†敭桳†湩†敶瑲捩污愠摮†栠牯穩湯慴†番据楴湯†漠†䍒⁃†湡牢捩⽫䅁⁃眠牯椠据畬楤杮†捳晡潦摬湩湡污敬摡愠摮氠晩⁴瑥挠浯汰瑥ꕥ⹇⹉††挠楨正湥††洠獥††獡††瀠牥††䤠䥓猠数楣楦慣楴湯†湡椠琠敨†敲畱物摥†楷瑤楷桴†〵浭†潬杮†潂扭祡†慮汩戠晥牯汰獡整楲杮甠瑰ㄠ‰敭整敨杩瑨㌱㈮⸷ਲ倀潲楶楤杮愠摮映硩湩楦牢敭桳漠㐱‵升⁍†敷杩瑨†椠†敲畱物摥†眠摩桴†眠瑩散敭瑮†潭瑲牡†敢潦敲†汰獡整楲杮†灵潴ㄠ洰栠楥桧ਊ煓٭㐊⸵〰W′浭琠楨正瀠慬湩挠浥湥⁴潭瑲牡戠湡獤椠挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮†›㐠猠湡⥤㨠⸳㠲ㄮ 䘀畬桳䈠湡।浣瀠牥洠܊㌱㈮⸸ल畓歮䈠湡ݤ㌱㈮⸸ଳ慒獩摥䈠湡ݤ㌱㈮⸸ఴ潍汵敤慂摮U‸浭琠楨正瀠慬湩挠浥湥⁴潭瑲牡戠湡湩†散敭瑮†潭瑲牡†㨱‴⠠‱挠浥湥⁴㨠†‴慳摮㨩⸳㈠⸹࠱㌱㤲㈮⸳㈠⸹࠳㌱㤲㐮È‸洠琠楨正†潭汵敤挠浥湥⁴洠牯慴慢摮†湩†睴挠慯獴†湵敤氠祡牥†㈱浭琠楨正眠瑩散敭瑮洠牯慴㨱‵ㄨ挠浥湥⁴›㔠††慳摮 琠灯†慬敹㘠浭†桴捩眠瑩散敭瑮洠牯慴㨱⠴‱散敭瑮㨠㐠猠湡⥤儮潐湩楴杮漠牢捩潷歲漠牢捩汦潯楲杮眠瑩散敭瑮洠牯慴㨱⠳挱浥湥㩴″慳摮 ܺ㌱㌮⸱㘱汆獵† †畒敬 sqm 3650
manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge:15.8.115.8.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge:15.9.115.9.2Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) :15.10.115.10.2Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead.&For thickness of tiles 10 mm to 25 mm.2For thickness of tiles above 25 mm and upto 40 mm.Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.7Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.¨Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :15.14.1Of area 3 sq. metres and below.15.14.2Of area beyond 3 sq. metres.}Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead:15.15.115.15.2Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead:15.16.1.Of sectional area below 40 square centimetres.15.16.22Of sectional area 40 square centimetres and above.Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres :15.17.1metre per metre span15.17.2cum per metre spanExtra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres :15.18.2 mtr/ mtr span15.18.1hDismantling steel work in single sections including dismembering and stacking within 50 metres lead in:15.19.1 R.S. Joists15.19.2 Channels, angles, tees and flatsüDismantling steel work in built up sections with span upto 10 meter and hieght 5 meter in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead.ÔDismantling steel work manually/ by mechanical means in built up sections with span upto 10 meter and hieght 5 meter without dismembering and stacking within 50 metres lead as per direction of Engineer-in-Charge.Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metreskg per metre spanExtra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres.kg per metre heightFExtra for marking of structural steel work required to be re- erected.FRemoval of old Tarfelt i/c disposal as directed by Engineer in charge.per sqmDemolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.xDismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of:15.27.1 G.S. Sheet15.27.2Asbestos/ Non asbestors sheetéDismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.¦Dismantling tiled roofing with battens boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.XDismantling wooden ballies in posts and struts including stacking within 50 metres lead.Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of :15.31.1T or L iron or pipe15.31.2R.C.C.Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead.sDismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.wDismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead.Dismantling expanded metal or I.R.C. fabrics f fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.$Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.13.67.1With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.13.67.2~With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre.13.67.3dWith water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work.¦Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work.Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new workBVarnishing with varnish of approved brand and manufacture:13.72.1hTwo or more coats of glue sizing with copal varnish over an under coat of flatting varnish.13.72.2aTwo or more coats glue sizing with spar varnish or an under coat of flatting varnish.]French spirit polishing: Two or more coats on new works including a coat of wood filler.nPolishing on wood work with ready mixed wax polish of approved brand and manufacture: New work.Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler.jFloor polishing on masonry or concrete floors with wax polish of approved brand and manufacture.MLettering with black Japan paint of approved brand and manufacture.per letter per cm heightEProviding and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on sqm 3550
as directed by Engineer-in-Charge.ÅDismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps:15.50.115.50.215.50.3200 mm diameter15.50.4250 mm diameter15.50.5300 mm diameter15.50.6350 mm diameter15.50.7400 mm diameter15.50.8440 mm diameterÍDismantling of manhole including R.C.C. top slab, C.I. cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead :15.51.1+Rectangular manhole 90x80 cm and 45 cm deep15.51.2-Rectangular manhole 120x90 cm and 90 cm deep.15.51.36Rectangular arch type manhole 140x90cm and 2.45m deep.15.51.40Circular manhole 122 cm diameter and 1.68 m deep'Extra for depth of manholes dismantled:15.52.14Rectangular manhole 90x80 cm and beyond 45 cm depth.15.52.25Rectangular manhole 120x90 cm and beyond 90 cm depth.15.52.3RRectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth).15.52.4LCircular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge.Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead :SDemolishing mud phaska in terracing and disposal of material within 50 metres lead.Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.ºDemolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge.»Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge :15.58.1Water bound macadam road15.58.2Bituminous road:Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge :15.59.1Up to 600 mm diameter per metre15.59.2Above 600 mm diameterãDismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge15.60.1Up to 150 mm diameter15.60.2ÜDismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 metres lead.ËDismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead:15.62.1!120 x 120 cm (outside to outside)15.62.2!210 x 120 cm (outside to outside)³Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in- charge.,Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :17.1.1]White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.17.1.2yStainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests.tProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :17.2.19W.C. pan with ISI marked white solid plastic seat and lid17.2.29W.C. pan with ISI marked black solid plastic seat and lid17.2.3qProviding and fixing AISI-304 (18/8) European type WC instead of white vitreous china pedestal type water closet.ÏProviding and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1:W.C. pan with ISI marked white solid plastic seat and lid.17.3.2:W.C. pan with ISI marked black solid plastic seat and lid.ßProviding and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low ²level flushing cistern with fitting and brackets, 40mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required White vitreous china dual purpose WC pan with white solid plastic seat and lid with 10 liter low level flushing cistern i/c C.P. flush bend.cProviding and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes ÷respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.6.1FOne urinal basin with 5 litre white P.V.C. automatic flushing cistern.17.6.2PRange of two urinal basins with 5 litre white P.V.C. automatic flushing cistern.17.6.3PRange of three urinal basins with10 litre white P.V.C.automaticflushing cistern.17.6.4PRange of four urinal basins with 10litre white P.V.C.automatic flushing cistern.»Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required.17.7.1HSingle half stall urinal with 5 litre P.V.C. automatic flushing cister n.17.7.2ORange of two half stall urinals with 5 litre P.V.C. automatic flushing cistern.17.7.3RRange of three half stall urinals with 10 litre P.V.C. automatic flushing cistern.17.7.4QRange of four half stall urinals with 10 litre P.V.C. automatic flushing cistern.ÃProviding and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required :17.8.1FSingle squatting plate with 5 litre P.V.C. automatic flushing cistern.17.8.2MRange of two squatting plates with 5 litre P.V.C. automatic flushing cistern.17.8.3PRange of three squatting plates with 10 litre P.V.C. automatic flushing cistern.17.8.4ORange of four squatting plates with 10 litre P.V.C. automatic flushing cistern.ÁProviding and fixing white vitreous china water less urinal of size 600x330x315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal.cProviding and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge.àProviding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :17.11.1\White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.17.11.2ZWhite Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.17.11.3\White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.17.11.4bWhite Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.17.11.5cWhite Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap.17.11.6cWhite Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap.17.11.7bWhite Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap.17.11.8White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated lever ISI marked.17.11.9White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked.17.11.10pOval shape wash basin over counter /under counter with 15 mm C.P brass pillar tap (Counter to be paid sepratly).17.11.11^Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap17.11.12]Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap.Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm.èProviding and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :17.14.1Kitchen sink with drain board 17.14.1.1510x1040 mm bowl depth 250mm. 17.14.1.2510x1040 mm bowl depth 225mm. 17.14.1.3510x1040 mm bowl depth 200mm. 17.14.1.4510x1040 mm bowl depth 178mm.17.14.2 Kitchen sink without drain board 17.14.2.1610x510 mm bowl depth 200 mm. 17.14.2.2610x460 mm bowl depth 200 mm. 17.14.2.3470x420 mm bowl depth 178 mm.)Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required :17.15.1Size450x300x150mm17.15.2Size600x450x200mm·Providing and fixing White glazed fire clay draining board of size 600x450x25mm with C.I. brackets including painting of brackets, cutting and making good the walls wherever required.RProviding and fixing white vitreous china water closet squatting pan (Indian type)17.17.1$Long pattern W.C. pan of size 580 mm17.17.2*Orissa pattern W.C. pan of size 580x440 mm^Extra for using coloured W.C. pan instead of white W.C. pan Orissa pattern W.C. pan 580x440 mmiProviding and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern.rProviding and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet:17.21.1 250x130x30 mm17.21.2 250x125x25 mm¸Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity17.22.1White17.22.2colouredProviding and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush capacity)17.23.117.23.2ColouredVProviding and fixing solid plastic seat with lid for pedestal type W.C. pan complete :17.24.117.24.2Black17.24.3%Coloured (other than black and white)SProviding and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively.\Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm.kProviding and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.zProviding and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :17.29.1'Flat back wash basin of size 630x450mm.17.29.2'Flat back wash basin of size 550x400mm.17.29.3(Angle back wash basin of size 600x480mm.17.29.4(Angle back wash basin of size 400x400mm.17.29.5'Flat back wash basin of size 450x300mm.17.29.6*Surgeon type wash basin of size 660x460mm.Providing and fixing kitchen sink including making all connections excluding cost of fittings. White glazed fire clay sink of size 600x450x250mm.vProviding and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings:17.31.1Size 450x300x150 mm.17.31.2Size 600x450x200 mm.0Providing and fixing soil, waste and vent pipes:17.32.1;Sand cast iron socket and spigot (S&S) pipe as per IS: 1729 17.32.1.1%75 mm dia with wall thickness of 5 mm 17.32.1.2&100 mm dia with wall thickness of 5 mm17.32.2;Spun cast iron socket and spigot (S&S) pipe as per IS: 3989 17.32.2.1'75 mm dia with wall thickness of 3.5 mm 17.32.2.2&100 mm dia with wall thickness of 4 mm 17.32.2.3$150mm dia with wall thickness of 5mm17.32.3ÔHubless Centrifugally cast (spun) iron pipe epoxy coated in side & out side including complete coupling assembly (EPDM rubber gasket stainless steel claim and external metallic/ protective shield as per IS:15905) 17.32.3.1 17.32.3.2'100 mm dia with wall thickness of 3.5mm 17.32.3.3%150mm dia with wall thickness of 4 mmProviding and filling sqm 3450
427 9.216 the joints with spun yarn cement slurry and cement mortar 1:2 ( 1 cement : 2 sand) in S.C.I./ C.I. Pipes :17.33.175 mm dia pipe17.33.2AProviding and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. :17.34.1For 75 mm dia pipe17.34.2For 100 mm dia pipe17.34.3For 150 mm dia pipe{Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.17.35.1 150 mm dia 17.35.1.1=Sand cast iron as per IS 1729 minimum wall thickness 6.5mm 17.35.1.2;Spun cast iron as per IS 3989 minimum wall thickness 5 mm 17.35.1.3FHubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm17.35.2 100 mm dia 17.35.2.1 17.35.2.2;Spun cast iron as per IS 3989 minimum wall thickness 4 mm 17.35.2.3DHubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm17.35.3 75 mm dia 17.35.3.1>Sand cast iron as per IS 1729 minimum wall thickness 6.5 mm 17.35.3.2=Spun cast iron as per IS 3989 minimum wall thickness 3.5 mm 17.35.3.33Providing and fixing plain bend of required degree.17.36.1 17.36.1.1 17.36.1.2 17.36.1.317.36.2 17.36.2.1<Sand cast iron as per IS 1729 minimum wall thickness 6.5mm 17.36.2.2 17.36.2.317.36.3 17.36.3.1 17.36.3.2 17.36.3.3,Providing and fixing heel rest sanitary bend17.37.1 17.37.1.1Sand cast iron as per IS - 1729 17.37.1.2Spun cast iron as per IS - 398917.37.2 17.37.2.1 17.37.2.2Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 17.38.1.1150x150x150x150 17.38.1.2Sand cast iron as per IS - 398917.38.2100x100x100x100mm 17.38.2.1 17.38.2.217.38.3 75x75x75x75mm 17.38.3.1 17.38.3.2DProviding and fixing double equal plain junction of required degree.17.39.1150X150X150X150 mm 17.39.1.117.39.2 17.39.2.1Sand cast iron as per IS 1729 17.39.2.2Spun cast iron as per IS 3989 17.39.2.3(Hubless cast(spun) iron as per IS- 1590517.39.375x75x75x75 mm 17.39.3.1 17.39.3.2 17.39.3.3Providing and fixing single equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.17.40.1150X150X150 mm 17.40.1.117.40.2100x100x100 mm 17.40.2.1 17.40.2.217.40.3 75x75x75 mm 17.40.3.1 17.40.3.2FProviding and fixing single equal plain junction of required degree :17.41.1 17.41.1.117.41.2 17.41.2.1 17.41.2.2 17.41.2.317.41.3 17.41.3.1 17.41.3.2 17.41.3.3¦Providing and fixing double unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75x75 mm17.42.117.42.2WProviding and fixing double unequal plain junction of required degree: 100x100x75x75 mm 17.43.1.1 17.43.1.2 17.43.1.3Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75 mm17.44.117.44.2UProviding and fixing single unequal plain junction of required degree : 100x100x75 mm17.45.117.45.217.45.3IProviding and fixing double equal plain invert branch of required degree:17.46.1100x100x100x100 mm 17.46.1.1 17.46.1.2 17.46.1.317.46.2 17.46.2.1 17.46.2.2JProviding and fixing single equal plain invert branch of required degree:17.47.1 17.47.1.1 17.47.1.2 17.47.1.317.47.2 17.47.2.1 17.47.2.2 17.47.2.3WProviding and fixing double unequal invert branch of required degree : 100x100x75x75 mm17.48.117.48.2ZProviding and fixing single unequal plain invert branch of required degree : 100x100x75 mm17.49.117.49.217.49.3?Hubless cast(spun) iron as per IS- 15905 minimum wall thickness@Providing and fixing sand cast iron S&S off sets as per IS: 172917.50.176 mm off sets 17.50.1.1With 75 mm dia pipe 17.50.1.2With 100 mm dia pipe17.50.2114 mm off sets 17.50.2.1 17.50.2.217.50.3152 mm off sets 17.50.3.1 17.50.3.2AProviding and fixing sand cast iron S&S off sets as per IS: 3989.17.51.175 mm off sets 17.51.1.1 17.51.1.2 17.51.1.3With 150 mm dia pipe17.51.2150 mm off sets 17.51.2.1 17.51.2.2 17.51.2.3]Providing and fixing door piece, insertion rubber washer 3mm thick, bolts and nuts complete :17.52.1 17.52.1.1 17.52.1.217.52.2 17.52.2.1 17.52.2.2$Providing and fixing terminal guard:17.53.1150mm 17.53.1.1 17.53.1.2 17.53.1.317.53.2 17.53.2.1 17.53.2.2'Hubless cast(spun) iron as per IS-1590517.53.3 17.53.3.1 17.53.3.2 17.53.3.3Providing and fixing collar:17.54.1 17.54.1.1%Sand cast iron S & S as per IS - 1729 17.54.1.2%Sand cast iron S & S as per IS - 398917.54.2 17.54.2.1 17.54.2.2$Sand cast iron S & S as per IS- 3989oProviding lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter:17.55.117.55.217.55.3qProviding and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :17.56.117.56.2Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of .cutting and making good the walls and floors :17.57.1100 mm inlet and 100 mm outlet 17.57.1.1%Spun cast iron S & S as per IS: 3989. 17.57.1.2%Sand Cast iron S & S as per IS: 1729. 17.57.1.317.57.2100 mm inlet and 75 mm outlet 17.57.2.1 17.57.2.2%Spun Cast iron S & S as per IS- 1729. 17.57.2.3*Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm)17.58.175 mm diameter17.58.2110 mm diameter÷Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.17.59.1 17.59.1.1 17.59.1.2110 mm17.59.2Single pushfit Coupler 17.59.2.1 17.59.2.217.59.3 17.59.3.1 17.59.3.2110x110x110 mm17.59.4 17.59.4.1 17.59.4.217.59.5 Bend 87.50 17.59.5.1 75 mm bend 17.59.5.2 110 mm bendÏProviding and fixing Unplasticised - PVC pipe clips of approved design to Unplasticised - PVC soil and waste pipes by means of bombay nail of required length including and making good the wall etc. complete.17.60.117.60.2Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outletÚProviding and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x1.6mm galvanised M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts
, bolts, and washers of size 25x6mm, one bolts on each side of the pipe.17.62.1UTotal bracket length 580mm of approved shape and design (for single, 100mm dia pipe).17.62.2STotal bracket length 810mm of approved shape and design (for two, 100mm dia pipes).17.62.3VTotal bracket length 1040mm of approved shape and design (for three, 100mm dia pipes).dCutting chases in brick masonry walls (clay brick/flyash brick/AAC blocks) for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 sand :6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 sand) :17.63.117.63.217.63.3 50 mm diagProviding and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.17.64.1Semi rigid pipe 17.64.1.1 17.64.1.217.64. teners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344- 413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).′浭挠浥湥⁴汰獡整景洠硩㨠J‵浭挠浥湥⁴汰獡整湯琠敨爠畯桧猠摩景猠湩汧牯栠污牢捩慷汬漠業ᵸ〲洠散敭瑮瀠慬瑳牥漠業⁸债㈱†浭†散敭瑮†汰獡整映湩獩敨眠瑩愠映潬瑡湩潣瑡漠敮瑡挠浥湥⁴景洠硩㨠s‵浭挠浥湥⁴汰獡整湯爠畯桧猠摩景猠湩汧牯栠污牢捩慷汬映湩獩敨楷桴愠映潬瑡湩潣瑡漠敮瑡挠浥湥⁴景洠硩¸‸†浭†挠浥湥⁴†汰獡整†湩†琠潷†挠慯獴甠摮牥氠祡牥ㄠ′浭琠楨正挠浥湥⁴汰獡整㨱‵ㄨ挠浥湥⁴›‵慳摮 楦楮桳摥眠瑩潴⁰慬敹洶桴捩散敭瑮瀠慬瑳牥ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⥤쬮㠱†洠†散敭瑮†瀠慬瑳牥†椠†睴†潣瑡湵敤慬敹㈱洠桴捩散敭瑮瀠慬瑳牥ㄠ㔺⠠‱散敭瑮㨠㔠猠湡⥤愠摮愠琠灯氠祡牥㘠浭琠楨正挠浥湥⁴汰獡整㨱″ㄨ挠浥湥⁴›″猠湡⥤映湩獩敨潲杵楷桴猠潰杮㰊‶洠挠浥湥⁴瀠慬瑳牥†景†業⁸㨠†㨱″⠠‱散敭瑮㨠㌠猠湡⥤Æ㘀洠散敭瑮瀠慬瑳牥ㄠ㌺⠠‱散敭瑮㨠㌠猠湡⥤†楦楮桳摥†楷桴†映潬瑡湩挠慯⁴漠敮瑡†散敭瑮†湡琠楨正†潣瑡†景†楌敭眠獡漠琠灯†景†慷汬桷湥†牤⁹映牯戠慥楲杮漠⹒⹃⹃猠慬獢愠摮戠慥獭팮潒杵†慣瑳†瀠慬瑳牥†甠瑰†〱†敨杩瑨愠潢敶†牧畯摮†敬敶眠瑩愠†業瑸牵漠慳摮†湡朠慲敶漠挠畲桳摥†瑳湯映潲洶†潴†ㄠ洰†潮業慮†楳敺†搠獡敨癯牥†湡椠据畬楤杮†桴映敲桳†汰獡整椠睴氠祡牥ⱳ†湵敤氠祡牥†㈱浭†散敭瑮瀠慬瑳牥†㨱‴⠠‱挠浥湥㩴†‴猠湡⥤†湡琠灯氠祡牥†ㄠ洰†散敭瑮†瀠慬瑳牥†ㄠ㌺†⠠‱散敭瑮›″慳摮 業數楷桴ㄠ┰映湩汥⁹牧畯摮摥†票牤瑡摥†楬敭†祢†潶畬敭†景挠浥湥䘠湩獩敨楷桴漠摲湩牡⁹散敭瑮댮敐扢敬†慤桳†汰獡整甠瑰ㄠ洰†敨杩瑨愠潢敶†牧畯摮†敬敶眠瑩愠†業瑸牵漠慷桳摥瀠扥汢牯挠畲桳摥猠潴敮㘠浭琠㈱㔮浭†潮業慮猠穩搠獡敨漠敶愠摮椠据畬楤杮†牦獥†汰獡整†湩†琠潷†氠祡牥湵敤慬敹㈱浭挠浥湥⁴汰獡整㨱‴ㄨ挠浥湥㩴†‴猠湡⥤†湡琠灯†慬敹ㄠ洰散敭瑮†汰獡整眠瑩挠浥湥⁴洠牯慴ㄠ㌺⠠‱挠浥湥㩴†″猠湡⥤†業數眠瑩ㄠ┰映湩汥⁹†朠潲湵敤†栠摹慲整†氠浩†戠⁹潶畬敭漠散敭瑮㬮牐癯摩湩†猠湡†映捡摥††汰獡整†甠瑰〱敭整†栠杩瑨††扡癯†朠潲湵†氠癥汥挠湯牣瑥漠戠楲正†慭潳牮⁹猠牵慦散椠睴潣瑡ⱳ戠獡潣瑡漠㌱洠桴捩湩挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮›㐠†慳摮Ⱙ挠敬牡湩琠敨†畳晲捡戠⁹挠浯楢杮†瑩†湡楦楮桳湩潣瑡漠‸浭桴捩湩挠浥湥⁴潭瑲牡†ㄠ㌺†⠠‱†散敭瑮›†″†慳摮 †湡慴楫杮漠瑵猠牵慦散朠慲湩祢洠捥慨楮慣牡慲杮浥湥⁴牯愠灰祬湩敳潣摮挠慯⁴祢洠捥慨楮慣洠慥獮†湩汣摵湩挠獯⁴漠愠汬洠瑡牥慩ⱬ氠扡畯Ⱳ愠摮吠愠摮倠椠据畬楤杮愠汬††敬摡†氠晩⁴†愠摮††捳晡潦摬湩†攠捴潣灭敬整訮硅牴映牯†牰癯摩湩愠摮†業楸杮†慷整牰潯楦杮†洠瑡牥慩†湩†挠浥湥⁴†汰獡整潷歲椠牰灯牯楴湯爠捥浯敭摮摥戠⁹桴慭畮慦瑣牵牥 瀀牥㔠‰杫挠浥湥⁴獵摥椠桴業ᑸ硅牴潦汰獡整楲杮⸳㔱ㄮf䔀瑸牥潩慷汬景栠楥桧⁴潭敲琠慨〱洠映潲牧畯摮映牯攠敶祲愠摤瑩潩慮敨杩瑨漠″牯瀠牡⁴桴牥潥ݦ㌱ㄮ⸵瘲湉整楲牯†慷汬漠栠楥桧⁴洠牯琠慨㘠†牦浯†汦潯氠癥汥†潦攠敶祲†摡楤楴湯污栠楥桧⁴景㌠洠漠慰瑲琠敨敲景B䔀瑸慲映牯瀠慬瑳牥湩湯挠物畣慬潷歲渠瑯攠捸敥楤杮㘠洠椠慲楤獵ܺ㌱ㄮ⸶湉漠敮挠慯ݴ㌱ㄮ⸶ల湉琠潷挠慯獴o䔀瑸慲†潦瀠慬瑳牥湩搠湯漠洠畯摬湩潣湲捩獥†牯†牡档瑩慲敶椠据畬楤杮†敮瑡映湩獩潴氠湩湡敬敶㩬⸳㜱ㄮ⸳㜱㈮E䔀瑸慲†潦瀠慬瑳牥湩匠桰牥捩污䜠潲湩摥挠楥楬杮汆睥湩潳晦瑩⸳㠱ㄮ匀桰牥捩污挠楥楬杮⸳㠱㈮䜀潲湩摥挠楥楬杮⸳㠱㌮䘀敬楷杮猠景楦獴ɢ圀獡敨猠潴敮†牧瑩†汰獡整漠攠瑸牥潩慷汬†景†栠楥桧⁴†灵潴†ㄠ‰†⹍†愠潢敶朠潲湵氠癥汥†湩†睴氠祡牥ⱳ†湵敤氠祡牥ㄠ洲散敭瑮瀠慬瑳牥ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⤠†畦牲睯湩琠敨†湵敤氠祡牥†楷桴猠牣瑡档湩琠潯ⱬ†灡汰楹杮†散敭瑮†汳牵祲漠琠敨†湵敤氠祡牥†⁀㈠†杋漠†散敭瑮瀠牥†猠畱牡†敭牴ⱥ†琠灯†氠祡牥†ㄠ洵散敭瑮†汰獡整ㄠㄺ㈯㈺†ㄨ†散敭瑮†›ㄠ㈯猠湡›′瑳湯档灩楰杮ㄠ洰潮業慮楳敺 湩瀠湡汥楷桴朠潲癯污牡畯摮愠数††愠灰潲敶††瀠瑡整湲†††湩汣摵湩捳畲扢湩愠摮†慷桳湩Ⱨ†桴琠灯†慬敹楷桴†牢獵敨愠摮†慷整琠攠灸獯琠敨猠潴敮†ꀠ†挠楨灰湩獧挬浯汰瑥††愠††瀠牥猠数楣楦慣楴湯愠摮搠物捥楴湯漠湅楧敮牥湩†挠慨杲†⠠慐浹湥⁴†映牯††牰癯摩湩牧潯敶桳污敢洠摡敳慰慲整祬⸩ŵ䘀牯業杮†牧潯敶†景†湵晩牯猠穩㈠‰漠㔱洠楷敤愠摮ㄠ‵浭搠敥⁰湩琠敨琠灯氠祡牥漠慷桳摥猠潴敮朠楲⁴汰獡整獡瀠牥愠灰潲敶慰瑴牥獵湩潷摯湥戠瑡整獮慮汩摥†琠†桴†湵敤†慬敹†湩汣摵湩敲潭慶景眠潯敤慢瑴湥ⱳ爠灥楡潴琠敨攠杤獥漠慰敮獬愠摮映湩獩楨杮琠敨朠潲癯潣灭敬整††獡††数†猠数楣楦慣楴湯†愠摮搠物捥楴湯漠桴湅楧敮牥椭档牡敧㨠»䔀瑸慲††潦†眠獡敨†朠楲⁴†瀠慬瑳牥††湯攠瑸牥潩⽲湩整楲牯†慷汬漠栠楥桧⁴洠牯桴湡†〱映潲朠潲湵⽤汦潯氠癥汥†潦癥牥⁹愠摤瑩潩慮栠楥桧⁴漠㌠†漠瀠牡⁴桴牥潥o䔀瑸慲†潦眠獡敨猠潴敮†牧瑩†汰獡整漠楣捲汵牡†眠牯†潮⁴†硥散摥湩†洶†椠慲楤獵⠠湩琠潷挠慯獴⸩ǘ䘀牯業杮†牧潯敶†景†湵晩牯猠穩映潲㈱ㅸ洲湡灵潴㈠砵㔱浭椠桴潴⁰慬敹†景†眠獡敨†瑳湯†牧瑩†瀠慬瑳牥摥猠牵慦散††愠††数††灡牰癯摥††瀠瑡整湲湩汣摵湩††瀠潲楶楤杮†††湡††映硩湩污浵湩浵†档湡敮獬†景†灡牰灯楲瑡猠穩湡琠楨正敮獳†渨瑯†敬獳†桴湡†′洠⥭慮汩摥琠桴湵敤慬敹楷桴爠獵⁴牰潯捳敲獷†愠摮†渠楡獬†愠摮†映湩獩楨杮†琠敨朠潲癯挠浯汰瑥愠瀠牥†灳捥晩捩瑡潩獮愠摮搠物捥楴湯漠桴湅楧敮牥椭桃牡敧礮硅牴潦獵湩桷瑩散敭瑮椠汰捡景漠摲湩牡⁹散敭瑮†湩†桴琠灯†慬敹漠琠敨椠整景眠獡敨瑳湯牧瑩瀠慬瑳牥ጮ牐癯摩湩愠摮†灡汰楹杮†㈱†浭†桴捩愨敶慲敧 牰浥硩摥映牯畭慬整湯潣瑡朠灹畳†氠杩瑨敷杩瑨††汰獡整†栠癡湩摡楤楴敶湡楬桧⁴敷杩瑨愠杧敲慧整獡瘠牥業畣楬整 †††瀠牥楬整††††敲灳捥楴敶祬挠湯潦浲湩潴䤠㩓㈠㐵‷倨牡⁴ㄭ愠摮䤠⥉ㄠ㜹ⰶ††灡汰敩†漠†栠捡敫⽤††湵癥湥戠捡杫潲湵猠捵愠戠牡戠楲正 戠潬正 䍒⁃眠牯漠眠污獬†湡挠楥楬杮†瑡†污汦潯獲†湡氠捯瑡潩獮攬捸畬楤杮†湩†慷汬眠楨档††慭⁹†挠浯†椠†挠湯慴瑣††楷桴搠浡湰獥†映湩獩敨湩猠潭瑯楬敮愠摮氠癥汥攠捴潣灭敬整央硅牴潦摡楤楴湯漠祳瑮敨楴潐祬獥整牴慩杮汵牡映扩敲漠敬杮桴㘠浭晥敦瑣癩楤浡瑥牥†ㄠⴰ〴†洠捩潲獮†愠摮†猠数楣楦牧癡瑩⁹†景†ㄠ㌮‴†潴†ㄠ㐮‰†湩†挠浥湥⁴汰獡整⽲潭瑲牡†戠⁹†獵湩†㈱朵獭†晏猠湹桴瑥捩†潐祬獥整琠楲湡畧慬映扩敲†潦〵†杋†散敭瑮†獵摥†湩†散敭瑮†潭瑲牡愠数楤敲瑣潩獮漠湅楧敮牥椭桃牡敧ᜮ数慢景㔠‰杫挠浥湥ꍴ牐癯摩湩愠摮†楦楸杮†敭桳†湩†敶瑲捩污愠摮†栠牯穩湯慴†番据楴湯†漠†䍒⁃†湡牢捩⽫䅁⁃眠牯椠据畬楤杮†捳晡潦摬湩湡污敬摡愠摮氠晩⁴瑥挠浯汰瑥ꕥ⹇⹉††挠楨正湥††洠獥††獡††瀠牥††䤠䥓猠数楣楦慣楴湯†湡椠琠敨†敲畱物摥†楷瑤楷桴†〵浭†潬杮†潂扭祡†慮汩戠晥牯汰獡整楲杮甠瑰ㄠ‰敭整敨杩瑨㌱㈮⸷ਲ倀潲楶楤杮愠摮映硩湩楦牢敭桳漠㐱‵升⁍†敷杩瑨†椠†敲畱物摥†眠摩桴†眠瑩散敭瑮†潭瑲牡†敢潦敲†汰獡整楲杮†灵潴ㄠ洰栠楥桧ਊ煓٭㐊⸵〰W′浭琠楨正瀠慬湩挠浥湥⁴潭瑲牡戠湡獤椠挠浥湥⁴洠牯慴ㄠ㐺†ㄨ†散敭瑮†›㐠猠湡⥤㨠⸳㠲ㄮ 䘀畬桳䈠湡।浣瀠牥洠܊㌱㈮⸸ल畓歮䈠湡ݤ㌱㈮⸸ଳ慒獩摥䈠湡ݤ㌱㈮⸸ఴ潍汵敤慂摮U‸浭琠楨正瀠慬湩挠浥湥⁴潭瑲牡戠湡湩†散敭瑮†潭瑲牡†㨱‴⠠‱挠浥湥⁴㨠†‴慳摮㨩⸳㈠⸹࠱㌱㤲㈮⸳㈠⸹࠳㌱㤲㐮È‸洠琠楨正†潭汵敤挠浥湥⁴洠牯慴慢摮†湩†睴挠慯獴†湵敤氠祡牥†㈱浭琠楨正眠瑩散敭瑮洠牯慴㨱‵ㄨ挠浥湥⁴›㔠††慳摮 琠灯†慬敹㘠浭†桴捩眠瑩散敭瑮洠牯慴㨱⠴‱散敭瑮㨠㐠猠湡⥤儮潐湩楴杮漠牢捩潷歲漠牢捩汦潯楲杮眠瑩散敭瑮洠牯慴㨱⠳挱浥湥㩴″慳摮 ܺ㌱㌮⸱㘱汆獵† †畒敬 sqm 3121
Flexible pipe (only in residential & complaxes) 17.64.2.1 17.64.2.2BProviding and fixing 100 mm sand cast Iron grating for gully trap.dProviding and fixing in position 25mm diameter mosquito proof coupling of approved municipal design.ÀProviding and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. sq. metre»Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6 mm thick hard board backing17.68.1Circular shape 450mm dia.17.68.2Rectangular shape 453x357mm17.68.3'Oval shape 450x350mm (outer dimensions)17.68.4Rectangular shape 1500x450 mmÊProviding and fixing glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.)Providing and fixing toilet paper holder:17.70.1 C.P. brass17.70.2Vitreous chinabProviding and fixing CP brass waste coupling of approved quality and make for sink and wash basin.17.71.13Waste coupling 31mm of 79mm length and 62mm breadth17.71.23Waste coupling 38mm of 83mm length and 77mm breadth_Providing and fixing CP brass bottle trap of approved quality and make for sink and wash basin.EProviding and fixing CP brass towel rail of approved quality and make17.73.1600x20mm17.73.2450x20mmTProviding and fixing CP brass towel ring of approved quality and make 200mm dia ringDProviding and fixing CP brass soap dish of approved quality and makeJProviding and fixing CP brass Urinal spreader of approved quality and makeæProviding and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall of standard shape with bracket of the same material with all fittings etc. of approved quality and conforming to IS: specification.eProviding and fixing C.P. brass grating of approved quality and make conforming to IS: specification.17.78.1 100 mm dia.aProviding and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.17.79.1UWaste coupling 31mm dia of 79mm length and 62mm breadth weighing not less than 45gms.17.79.2VWaste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60gms.>Providing and fixing PTMT Bottle Trap for Wash basin and sink.17.80.1Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm Dbreadth with 25mm minimum water seal, weighing not less than 260gms.17.80.2ÐBottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263gms.ëProviding and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. Weighing not less than 105 gms.áProviding and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms.ªProviding and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.17.83.1x450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms.17.83.2y600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms.Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes. Weighing not less than 60 gms.´Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms.¥Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms.þPainting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint over a coat of zinc chromate yellow primer (of approved quality) on the outside surface of the cistern, flush pipe, other fittings, etc. complete for new work.Re-painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint on the outside surface of the cistern, flush pipe, other fittings, etc. complete including polishing of wooden seat and lid and cleaning of W.C. pan with acid wherever necessary.©Repainting C.I. cistern with synthetic enamel paint of approved colour brand and manufacture on the outside surface of cistern flush pipe, other fittings etc. complete.òPainting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :17.91.175 mm diameter pipe17.91.2100 mm diameter pipe17.91.3150 mm diameter pipeÀRepainting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as chocolate, grey or buff etc :17.92.117.92.217.92.3=Repainting bath tub of size 1700x730x430mm with enamel paint.2Providing and laying Ceramic glazed half round pipe drain (having thickness 9 to 10mm) of approved make in colours such as White, Ivory, Grey, or any other colour, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete.17.94.1100 mm dia half round pipe17.94.2150 mm dia half round pipe17.94.3200mm dia half round pipeMProvoding d fixing coupler for PVC pipe and fitting waste rain water drainageaProviding and fixing PVC pipe and fitting waste rainwater draingedissssposal basin conection 40mmechMProvodin and fixing90degree band PVC pipes nd fitting waste/Rain water rie /wñConstruction of manually operated fire based incinerator for girls-toilet i/c (i) Fire and ash collection chamber 0.60x0.60 m, made of calcium silicate bricks, having 12mm dia steel bars grating @10 cm c/c, i/c MS mesh weldedon top including 300 mm x 450 mm MS openable door of half grill and half MS plate (3mm thick ).(ii) 0.40 m X 0.40 m duct made of 1.6 mm thick MS sheet for dropping napkins from the toilet opening.(iv) 150mm dia Class 'C' heavy duty MS pipe conforming to IS 3589/1239 for gas emission with cowel, up to 2.10 meter height above terrace level.(v) Opening in wall having MS flap (1.6mm thick) of size 0.25X 0.25 m, finished with granite.etc complete as per standard drawing no. 5313-B-NB4-9919- R1 dated 21.02.201717.99.1Fo f fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.$Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.13.67.1With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.13.67.2~With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre.13.67.3dWith water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work.¦Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work.Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new workBVarnishing with varnish of approved brand and manufacture:13.72.1hTwo or more coats of glue sizing with copal varnish over an under coat of flatting varnish.13.72.2aTwo or more coats glue sizing with spar varnish or an under coat of flatting varnish.]French spirit polishing: Two or more coats on new works including a coat of wood filler.nPolishing on wood work with ready mixed wax polish of approved brand and manufacture: New work.Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler.jFloor polishing on masonry or concrete floors with wax polish of approved brand and manufacture.MLettering with black Japan paint of approved brand and manufacture.per letter per cm heightEProviding and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on sqm 3021
r ground floor buildings.nos17.99.2'For Ground floor & Ist floor buildings.17.99.35Add extra for every additional floor above Ist floor.(Providing & Fixing Complete item of high-performance sound- insulating waste-water piping system (low Noise Drainage System) pipe having following properties 1. Density of pipe material is 1.9 g/cm^3 2. Tensile strength of 20n/mm^2 3. 3 layer of polypropylene with modulus of elasticity 1500 n/mm^2 4. Single (1) layer of polypropylene with modulus of elasticity 3800 n/mm^2, 5. Pipe handle the waste liquid with ph value 2 to 12. 6. Hot water resistant - short term 95°c / 203°f and long term 90°c / 194°f. Co-efficient of linear expansion .09 mm/mk. 17.100.1.Pipe 17.100.1.1160mm 17.100.1.2110mm 17.100.1.3 17.100.1.417.100.2Heavy Duty Saddle With Rubber 17.100.2.1 17.100.2.2 17.100.2.375mm 17.100.2.440mm17.100.3Bend without door 17.100.3.1 17.100.3.2 17.100.3.3 17.100.3.417.100.4Bend with door 17.100.4.1160 mm 17.100.4.2 17.100.4.3 17.100.4.417.100.5 Tee with door 17.100.5.1 17.100.5.2 17.100.5.3 17.100.5.417.100.6Tee without door 17.100.6.1 17.100.6.2 17.100.6.3 17.100.6.417.100.7Y Tee without door 17.100.7.1 17.100.7.2 17.100.7.3 17.100.7.417.100.8Double Y Tee without door 17.100.8.1 17.100.8.2 17.100..3 17.100.8.417.100.9 17.100.9.1 17.100.9.2 17.100.9.3 17.100.9.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.15 mm nominal outer dia Pipes.32 mm nominal outer dia Pipes.40 mm nominal outer dia Pipes.FConcealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes.[Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work18.7.7!62.50 mm nominal inner dia Pipes.18.7.875 mm nominal inner dia .Pipes.18.7.9100mm nominal inner dia .Pipes.18.7.10150 mm nominal inner dia Pipes.yProviding and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.40 mm dia. nominal bore50 mm dia. nominal boreoConcealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall.18.8.3.765 mm dia. nominal bore18.8.3.880 mm dia. nominal bore£Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment)18.9.118.9.1.115.88 mm outer diapipe 18.9. 1.222.22 mm outer diapipe18.9.1.328.58 mm outer diapipe18.9.1.434.00 mm outer dia Pipe18.9.1.542.70 mm outer dia Pipe18.9.1.648.60 mm outer dia Pipe18.9.2Internal work - Concealed Pipe18.9.2.115.88 mm outer dia .Pipes.18.9.2.222.22 mm Outer diaPipes]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :18.12.11With C.I. wheel of approved quality (screwed end) 18.12.1.1 18.12.1.232 mm nominal bore. 18.12.1.340 mm nominal bore 18.12.1.450 mm nominal bore 18.12.1.565 mm nominal bore 18.12.1.680 mm nominal bore18.12.2,With brass lever handle of approved quality. 18.12.2.1 18.12.2.2 18.12.2.3 18.12.2.418.13.318.13.418.14 3TProviding and fixing gun metal non- return valve of approved quality (screwed end) :18.15.1 18.15.1.1 Horizontal 18.15.1.2Vertical18.15.2 18.15.2.1 18.15.2.218.15.3 18.15.3.1 18.15.3.218.15.4 18.15.4.1 18.15.4.218.15.5 18.15.5.1 18.15.5.218.15.6 18.15.6.1 18.15.6.2aProviding and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :18.16.118.16.218.16.3IProviding and fixing uplasticised PVC connection pipe with brass unions :18.17.1 30 cm length 18.17.1.1 18.17.1.218.17.2 45 c suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre tocentre, and cross “T” of size 24x28mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mmpanel to from grid of size 600x600 mm, resting on periphery walls/ partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000Ӟ洁洀 洀愀搀攀 漀昀 ⸀㐀 洀洀 琀栀椀挀欀 ⠀洀椀渀椀洀甀洀⤀ 猀栀攀攀琀 眀椀琀栀 琀栀攀 栀攀氀瀀 漀昀 爀愀眀氀瀀氀甀最猀 愀琀 㐀㔀 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 眀椀琀栀 ㈀㔀 洀洀 氀漀渀最 搀爀礀 眀愀氀氀 猀挀爀攀眀猀 䀀 ㈀㌀ 洀洀 椀渀琀攀爀瘀愀氀 愀渀搀 氀愀礀椀渀最 㔀 洀洀 琀栀椀挀欀 搀攀渀猀椀昀椀攀搀 攀搀最攀猀 ㌀㠀㠀愀氀瘀愀渀椀 猀椀氀椀挀愀琀攀 挀攀椀氀椀渀最 琀椀氀攀猀 漀昀 愀瀀瀀爀漀瘀攀搀 琀攀砀琀甀爀攀 椀渀 琀栀攀 最爀椀搀Ⰰ 椀渀挀氀甀搀椀渀最Ⰰ 挀甀琀琀椀渀最⼀ 洀愀欀椀渀最 漀瀀攀渀椀渀最 昀漀爀 猀攀爀瘀椀挀攀猀 氀椀欀攀 搀椀昀昀甀猀攀爀猀Ⰰ 最爀椀氀氀猀Ⰰ 氀椀最栀琀 昀椀琀琀椀渀最猀Ⰰ 昀椀砀琀甀爀攀猀Ⰰ 猀洀漀欀攀 搀攀琀攀挀琀漀爀猀 攀琀挀⸀Ⰰ 眀栀攀爀攀瘀攀爀 爀攀焀甀椀爀攀搀⸀䴀愀椀渀 ᠀吠ᤀ†爀甀渀渀攀爀猀 琀漀 戀攀 猀甀猀瀀攀渀搀攀搀 昀爀漀洀 挀攀椀氀椀渀最 甀猀椀渀最 䜀⸀䤀⸀ 猀氀漀琀琀攀搀 挀氀攀愀琀猀 漀昀 猀椀稀攀 ㈀㔀砀㌀㔀砀⸀㘀 洀洀 昀椀砀攀搀 琀漀 挀攀椀氀椀渀最 眀椀琀栀 ㈀⸀㔀 洀洀 搀椀愀 愀渀搀 㔀 洀洀 氀漀渀最搀愀猀栀 昀愀猀琀攀渀攀爀猀Ⰰ 㐀 洀洀 䜀⸀䤀⸀ 愀搀樀甀猀琀愀戀氀攀 爀漀搀猀 眀椀琀栀 ㌀㠀㠀愀氀瘀愀渀椀稀攀搀 猀琀攀攀氀 氀攀瘀攀氀挀氀椀瀀猀 漀昀 猀椀稀攀 㠀㔀 砀 ㌀ 砀 ⸀㠀 洀洀Ⰰ 猀瀀愀挀攀搀 愀琀 ㈀ 洀洀 挀攀渀琀爀攀 琀漀 挀攀渀琀爀攀 愀氀漀渀最 洀愀椀渀 ᠀吠ᤀⰠ 戀漀琀琀漀洀 攀砀瀀漀猀攀搀 眀椀琀栀 ㈀㐀 洀洀漀昀 愀氀氀 吀猀攀挀琀椀漀渀猀 猀栀愀氀氀 戀攀 瀀爀攀ⴀ 瀀愀椀渀琀攀搀眀椀琀栀 瀀漀氀礀猀琀攀爀 戀愀欀攀搀 瀀愀椀渀琀Ⰰ 昀漀爀 愀氀氀 栀攀椀最栀琀猀Ⰰ 愀猀 瀀攀爀 猀瀀攀挀椀昀椀挀愀琀椀漀渀猀Ⰰ 搀爀愀眀椀渀最猀 愀渀搀 愀猀 搀椀爀攀挀琀攀搀 戀礀 䔀渀最椀渀攀攀爀ⴀ 椀渀ⴀ䌀栀愀爀最攀⸀一漀琀攀 㨀ⴀ 伀渀氀礀 挀愀氀挀椀甀洀 猀椀氀椀挀愀琀攀 昀愀氀猀攀 挀攀椀氀椀渀最 愀爀攀愀 眀椀氀氀 戀攀 洀攀愀猀甀爀攀搀 昀爀漀洀 眀愀氀氀 琀漀 眀愀氀氀⸀ 一漀 搀攀搀甀挀琀椀漀渀 猀栀愀氀氀 戀攀 洀愀搀攀 昀漀爀 攀砀瀀漀猀攀搀 昀爀愀洀攀猀⼀ 漀瀀攀渀椀渀最 ⠀挀甀琀 漀甀琀猀⤀ 栀愀瘀椀渀最 愀爀攀愀 氀攀猀猀 琀栀愀渀 ⸀㌀ 猀焀洀⸀吀栀攀 挀愀氀挀椀甀洀 猀椀氀椀挀愀琀攀 挀攀椀氀椀渀最 琀椀氀攀 猀栀愀氀氀 栀愀瘀攀 一刀䌀 瘀愀氀甀攀 漀昀 ⸀㔀 ⠀䴀椀渀椀洀甀洀⤀Ⰰ 氀椀最栀琀 爀攀昀氀攀挀琀椀漀渀 㸀 㠀㔀─Ⰰ 渀漀渀ⴀ 挀漀洀戀甀猀琀椀戀氀攀 愀猀 瀀攀爀 䈀⸀匀⸀ 㐀㜀㘀 瀀愀爀琀 䤀嘀Ⰰ ─ 栀甀洀椀搀椀琀礀 爀攀猀椀猀琀愀渀挀攀 愀渀搀 愀氀猀漀 栀愀瘀椀渀最 琀栀攀爀洀愀氀 挀漀渀搀甀挀琀椀瘀椀琀礀᐀牐癯摩湩湡楦楸杮甠癰汰湡Ⱬ倠慬歮猠穩㌨〴堠㈠〷‰ 浭愠数灡牰癯摥猠慨敤桴慰敮桳污敢氠獡牥挠瑡整湥景瀠慬歮映硩湩牴浩映硩摥愠摮挠牯敮摥敧漠散汩湩楦數⁵癰汣灩猠浡潣潬牵愠摮瀠潲楶楤杮愠摮映硩湩景映慲敭眠牯慭敤漠灳捥慩敳瑣潩獮潰敷牰獥敳牦浯䴠匮桳敥獴愠摮朠污慶楮敺楷桴稠湩潣瑡湩景ㄠ㔲朠獭猯浱⠠潢桴猠摩湩汣獵癩⥥愠数卉㨠㈠㜷愠摮挠湯楳瑳湩景愠杮敬挠敬瑡景猠穩㔲洠楷敤砠ㄠ㘮洠桴捩楷桴映慬杮獥漠㜲洠湡㜳浭瑡ㄠ〲‰浭挠湥牴潴挠湥牴ⱥ漠敮映慬杮楦數潴ʗ琀敨挠楥楬杮眠瑩慤桳映獡整敮㈱㔮洠楤⁸〵浭氠湯楷桴㘠浭搠慩戠汯獴漬桴牥映慬杮景挠敬瑡映硩摥琠桴湡汧慨杮牥景㈠砵〱へ㔮‰浭漠敲畱物摥氠湥瑧楷桴渠瑵…潢瑬景爠煥極敲楳敺愠摮漠桴牥攠摮漠湡汧慨杮牥映硩摥眠瑩湩整浲摥慩整䜠䤮档湡敮獬㐠砵㔱へ㤮洠畲湮湩瑡琠敨猠慰楣杮漠㈱〰洠散瑮敲琠散瑮敲潴眠楨档琠敨挠楥楬杮猠捥楴湯〠㔮洠桴捩潢瑴浯眠摥敧漠〸洠楷桴琠灡牥摥映慬杮獥漠㘲洠慥档栠癡湩楬獰漠〱㔮洠Ɑ愠⁴㔴‰浭挠湥牴潴挠湥牴ⱥ猠慨汬戠楦數湩愠搠物捥楴湯瀠牥数摮捩汵牡樬琠楲湥汣灩椠据畬敤湩琠楨瑩浥愠祮漠桴牥椠整潮⁴敢瀠楡敳牰瑡祬挠浯汰瑥湩愠汬爠獥数瑣愠数桴楤敲瑣潩獮漠湅楧敮牥椭桃牡敧Μ倁爀漀瘀椀搀椀渀最 ☀ 䘀椀砀椀渀最 倀嘀䌀 挀攀椀氀椀渀最猀礀猀琀攀洀 瀀爀漀昀椀氀攀 瀀愀渀攀氀 眀椀琀栀 挀氀椀挀欀 猀礀猀琀攀洀椀渀琀攀爀氀漀挀欀 瀀愀渀攀氀 猀椀稀攀 㐀 洀洀砀㌀㐀 洀洀砀洀洀 爀攀猀椀猀琀愀渀挀攀 琀漀 眀攀愀琀栀攀爀 瀀攀爀昀攀挀琀 昀椀渀椀猀栀 椀渀 眀漀漀搀 最爀愀椀渀 ☀ 猀漀氀椀搀 挀漀氀漀甀爀 洀愀椀渀琀攀渀愀渀挀攀 昀爀攀攀 刀攀猀椀猀琀愀渀挀攀 琀漀 眀攀愀琀栀攀爀 琀爀甀氀礀 愀渀琀椀 戀愀挀琀攀爀椀愀氀⸀ 眀椀琀栀 攀搀最攀 瀀爀漀昀椀氀攀 䨀ⴀ琀爀椀洀 漀渀 瀀攀爀椀瀀栀攀爀礀 ☀ 挀攀渀琀攀爀 瀀爀漀昀椀氀攀 吀ⴀ琀爀椀洀 椀渀 瀀愀渀攀氀 樀漀椀渀琀 䌀漀洀瀀氀攀琀攀 匀礀猀琀攀洀 琀漀 戀攀 昀椀砀攀搀 漀渀 䜀⸀䤀⸀ 昀爀愀洀攀眀漀爀欀 漀昀 挀攀椀氀椀渀最猀攀挀琀椀漀渀 愀琀 㐀㔀 洀洀 搀椀猀琀愀渀挀攀 眀椀琀栀 攀渀琀攀爀 猀攀挀琀椀漀渀 猀甀猀瀀攀渀搀攀搀 戀礀 爀漀漀昀 戀礀 䜀⸀䤀⸀ 愀渀最氀攀 栀愀渀最攀爀 椀渀 瀀爀漀瀀攀爀 氀椀渀攀 ☀ 氀攀瘀攀氀 攀琀挀 挀漀洀瀀氀攀琀攀 倀刀伀䐀唀䌀吀 倀䔀䌀䤀䘀䤀䌀䄀吀䤀伀一匀㨀䴀攀攀琀猀 漀爀 攀砀挀攀攀搀猀 琀栀攀 猀琀愀渀搀愀爀搀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 漀昀 ⠀䄀匀吀䴀 䐀ⴀ㐀㐀㜀㜀⤀ 愀渀搀 椀琀猀 爀攀昀攀爀攀渀挀攀搀 搀漀挀甀洀攀渀琀猀⸀ 䤀洀瀀愀挀琀 爀攀猀椀猀琀愀渀挀攀㨀 一漀 搀攀昀漀爀洀愀琀椀漀渀漀戀猀攀爀瘀攀搀⸀ ⠀吀攀猀琀攀搀 愀琀 㔀 䰀䈀匀⤀ 吀攀渀猀椀氀攀 猀琀爀攀渀最琀栀Ⰰ 䴀倀愀㨀 㸀㌀㜀⸀ 吀攀渀猀椀氀攀 洀漀搀甀氀甀猀Ⰰ 䴀倀愀㨀 㸀㈀ 匀甀爀昀愀挀攀 搀椀猀琀漀爀琀椀漀渀㨀 一漀渀攀 愀琀 ㈀ 䘀 匀焀甀愀爀攀渀攀猀猀㨀 㰀⼀㠀ᴀ†漀昀 猀焀甀愀爀攀䰀攀渀最琀栀㨀 圀椀琀栀椀渀 밀ᴀ†漀昀 猀瀀攀挀椀昀椀挀愀琀椀漀渀 䰀漀挀欀 挀漀渀琀爀漀氀㨀 䌀漀洀瀀氀椀攀猀 䌀漀氀漀爀 䌀栀愀渀最攀㨀 㰀㈀ 最爀愀礀猀挀愀氀攀猀 ⠀㘀 栀爀猀 甀渀搀攀爀 ㈀ 圀⼀洀㈀ 唀嘀 爀愀搀椀愀琀椀漀渀 愀琀 㔀 搀攀最爀攀攀猀⤀ 需ĄProviding & Fixing of Mineral Fibre 1200x300mm (Nominal Size) tiles Acoustical Suspended Ceiling System with 16mm thick Beveled Tegular Edge Tiles and 15mm Bolt Slot Exposed Grid. The tiles shall have fissured visual with acoustical punctures, Humidity Resistance (RH) of 99%, NRC 0.6 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C- 423 standard, CAC of 35db as per ASTM E1414, Light Reflectance 87% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 0/7 and Class A as per ASTM E84 with 16mm Beveled Tegular edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building sqm 2921
428 9.217 18.17.2.1 18.17.2.2³Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :-18.18.1BWith common burnt clay bricks of 25 kg /sqcm compressive strength.18.18.2@With well burnt flyash bricks of 50 kg/sqm compressive strength.[Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design18.19.118.19.2(With flyash bricks of 50 kg/cm2 strengthaConstructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :18.20.1@With common burnt clay bricks of 25 kg/cm2 compressive strength.18.20.2(With flyash bricks of 50kg/cm2 strength.MConstructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :18.21.118.21.24With flyash bricks of 50kg/sqm compressive strength.Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :18.22.115 mm diameter pipe.18.22.220 mm diameter pipe.18.22.325 mm diameter pipe.18.22.432 mm diameter pipe.18.22.540 mm diameter pipe.18.22.650 mm diameter pipe.ZRepainting G.I. pipes and fittings with synthetic enamel white paint of approved quality :18.23.118.23.218.23.325 mm diameter pipe18.23.432 mm diameter pipe18.23.540 mm diameter pipe18.23.650 mm diamet metre 238
429 9.218 er pipehPainting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :18.24.115 mm diameter pipe18.24.220 mm diameter pipe18.24.318.24.418.24.518.24.618.24.765 mm diameter pipe18.24.880 mm diameter pipeEProviding and filling sand all-round the G.I. pipes in external work.18.25.118.25.218.25.318.25.418.25.518.25.618.25.718.25.8 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)18.26.118.26.218.26.318.26.418.26.518.26.650mm nominal bore18.26.765mm nominal bore18.26.8äProviding and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :18.27.115 mm nominal bore.18.27.220 mm nominal bore.18.27.325 mm nominal bore.18.27.418.27.540 mm nominal bore.18.27.650 mm nominal bore.18.27.765 mm nominal bore.18.27.880 mm nominal bore.Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank;Providing and fixing brass bib cock of approved quality18.29.118.29.2:Providing and fixing brass stop cock of approved quality :18.30.118.30.2hProviding and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore.Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore.Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal boreProviding and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore.Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal boreProviding and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore.Providing and fixing C.P. brass pillar cock approved quality and make conforming to IS: specification. 15 mm nominal bore 125 mm long foam flow.Providing and fixing C.P. brass basin mixer of approved quality and make conforming to IS: specification.15 mm nominal bore.|Providing and fixing C.P. brass wall mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore.|Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore.Providing and fixing C.P. brass elbow operated bibcock of approved quality and make conforming to IS: specification. 15 mm nominal bore.Providing and fixing C.P. brass elbow operated pillar cock of approved quality and make conforming to IS: specification. 15 mm nominal bore.DProviding and fixing C.P. brass shower rose with 15 or 20 mm inlet :18.43.118.43.2TProviding and fixing PTMT bib cock of approved quality and colour 15mm nominal bore.18.44.1'86 mm long weighing not less than 88 gm18.44.2(122 mm long weighing not less than 99 gm18.44.3(165mm long weighing not less than 110 gm18.44.4&90mm long weighing not less than 93 gmCProviding and fixing PTMT stop cock of approved quality and colour.18.45.1=15 mm nominal bore, 86mm long. Weighing not less than 88 gms.18.45.2<20mm nominal bore, 89mm long. Weighing not less than 88 gms.18.45.3SConcealed stop cock, 15mm nominal bore, 108mm long. Weighing not less than 108 gms.EProviding and fixing PTMT pillar cock of approved quality and colour.18.46.1>15mm nominal bore, 107mm long. Weighing not less than 110 gms.18.46.2G15mm nominal bore, 125mm long foam flow weighing not less than 120 gms.DProviding and fixing PTMT, push cock of approved quality and colour.18.47.1=15 mm nominal bore, 98mm long. Weighing not less than 75 gms.18.47.2<15 mm nominal bore, 80mm long weighing not less than 46 gms.AProviding and fixing PTMT grating of approved quality and colour.18.48.1Circular type. 18.48.1.1100 mm nominal dia. 18.48.1.2)125 mm nominal dia with 25 mm waste hole.18.48.2,Rectangular type with openable circular lid. 18.48.2.1M150 mm nominal size square 100 mm diameter of the inner hinged round grating.\Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms.]Providing and fixing PTMT swivelling shower, 1 sqm 2742
430 9.219 倮牢獡睴慷⁹湡汧潣正眠瑩慷汬映慬杮景愠灰潲敶畱污瑩⁹潣普牯業杮琠卉猠慴摮牡獤㔱洠潮業慮潢敲倀潲楶楤杮愠摮映硩湩⹃⹐戠慲獳眠污潭湵楴杮琯扡敬洠畯瑮摥猠湩潣正眠瑩慷汬映慬杮景愠灰潲敶畱污瑩⁹潣普牯業杮潴䤠⁓瑳湡慤摲ⱳ㔱洠潮業慮潢敲倀潲楶楤杮愠摮映硩湩湩瀠獯瑩潩敢瑳䤠摮慩效污桴䘠畡散⁴楷桴㠠浭搠慩ㄠ㈮洠瑥牥氠湯汆硥扩敬吠扵湡慷汬戠慲正瑥眠瑩⹎删嘮渨湯爭瑥牵慷汬⸩j倀潲楶楤杮愠摮映硩湩⹃⹐戠慲獳匠潨敷牡楷桴眠污汦湡敧漠灡牰癯摥焠慵楬祴挠湯潦浲湩瑧卉猠慴摮牡獤ܬ㠱㘮⸸ܱ㠱㘮⸸ଲ〳‰浭氠湯ݧ㠱㘮⸸ଳ〶‰浭氠湯�牐癯摩湩Ⱨ氠祡湩湡潪湩楴杮朠慬敺瑳湯睥牡楰数汣獡偓ㄭ眠瑩瑳晩業瑸牵景挠浥湥⁴潭瑲牡椠桴牰灯牯楴湯漠㨱‱ㄨ挠浥湥⁴›‱慳摮 湩汣摵湩整瑳湩景樠楯瑮瑥挠浯汰瑥›硅慣慶楴湯琠敢瀠楡敳数慲慴祬⸹⸱ر㤱ㄮ㈮⸹⸱س㤱ㄮ㐮㈀〳洠楤浡瑥牥⸹⸱ص㤱ㄮ㘮²倀潲楶楤杮愠摮氠祡湩散敭瑮挠湯牣瑥㨱㨵〱⠠‱散敭瑮㨠㔠猠湡›〱朠慲敤瑳湯条牧来瑡〴洠潮業慮楳敺 污潲湵⹓⹗瀠灩獥椠据畬楤杮戠摥挠湯牣瑥獡瀠牥猠慴摮牡敤楳湧غ㤱㈮ㄮ〰洠楤浡瑥牥匠圮楰数⸹⸲ᤲ㔱‰浭搠慩敭整⹓⹗瀠灩٥㤱㈮㌮㈀〰洠楤浡瑥牥匠圮楰数⸹⸲ᤴ㌲‰浭搠慩敭整⹓⹗瀠灩٥㤱㈮㔮㈀〵洠楤浡瑥牥匠圮楰数⸹⸲ᤶ〳‰浭搠慩敭整⹓⹗瀠灩멥牐癯摩湩湡慬楹杮挠浥湥⁴潣据敲整ㄠ㔺ㄺ‰ㄨ挠浥湥⁴›‵慳摮㨠ㄠ‰牧摡摥猠潴敮愠杧敲慧整㐠‰浭渠浯湩污猠穩⥥甠瑰慨湵档獥漠⹓⹗瀠灩獥椠据畬楤杮戠摥挠湯牣瑥獡瀠牥猠慴摮牡敤楳湧㨠⸹⸳ر㤱㌮㈮⸹⸳س㤱㌮㐮⸹⸳ص㤱㌮㘮Ú倀潲楶楤杮愠摮氠祡湩敢潬⁷牧畯摮甠灮慬瑳捩獩摥倠䍖瀠灩潴眠瑩瑳湡潷歲湩牰獥畳敲漠‴杫振㉭猠楯摬眠獡整瀠灩獥挠湯楦浲湩潴䤠㩓㌱㤵′湡卉㐺㠹‵湩汣摵湩潪湩楴杮眠瑩敳污爠湩潣普物業杮琠卉㨠㈵㈸氠慥楶杮映〱浭朠灡映牯琠敨浲污攠灸湡楳湯愠汬渠捥獥慳祲映瑩楴杮瑥挠浯汰瑥䔠捸癡瑡潩潴戠慰摩猠灥牥瑡污⸹⸴⸱ㄱ‰浭搠慩敭整䑏⠠業眠污桴捩湫獥⸳洲⥭⸹⸴⸲㘱‰浭搠慩敭整䑏⠠業眠污桴捩湫獥⸴洰⥭⸹⸴⸳〲‰浭搠慩敭整䑏⠠業眠污桴捩湫獥⸴洹⥭⸹⸴⸴㔲‰浭搠慩敭整䑏⠠業眠污桴捩湫獥⸶洲⥭⸹⸴⸵〳‰浭搠慩敭整䑏⠠業眠污桴捩湫獥⸷洷⥭®倀潲楶楤杮愠摮氠祡湩散敭瑮挠湯牣瑥㨱㨳‶ㄨ挠浥湥㩴㌠猠湡㩤㘠朠慲敤瑳湯条牧来瑡〲洠潮業慮楳敺 污潲湵噐⹃瀠灩獥椠据畬楤杮戠摥挠湯牣瑥獡瀠牥猠慴摮牡敤楳湧غ㤱㔮ㄮ〱洠楤浡瑥牥倠䍖楰数⸹⸵ᤲ㘱‰浭搠慩敭整噐⹃瀠灩٥㤱㔮㌮㈀〰洠楤浡瑥牥倠䍖楰数⸹⸵ᤴ㔲‰浭搠慩敭整噐⹃瀠灩٥㤱㔮㔮㌀〰洠楤浡瑥牥倠䍖瀠灩륥牐癯摩湩湡慬楹杮挠浥湥⁴潣据敲整ㄠ㌺㘺⠠‱散敭瑮㨠㌠猠湡›‶牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩⥥甠⁰潴栠畡据敨景倠䍖楰数湩汣摵湩敢潣据敲整愠数瑳湡慤摲搠獥杩غ㤱㘮ㄮ⸹⸶ز㤱㘮㌮⸹⸶ᤴ㔲‰浭搠慩敭整噐⹃倠灩٥㤱㘮㔮Ġ倀潲楶楤杮愠摮映硩湩煳慵敲潭瑵⹓⹗朠汵祬琠慲⁰汣獡偓‱潣灭敬整眠瑩⹃⹉朠慲楴杮戠楲正洠獡湯祲挠慨扭牥眠瑩慷整楴桧⁴⹃⹉挠癯牥眠瑩牦浡景㌠〰砠〳‰浭猠穩椨獮摩⥥琠敨眠楥桧⁴景挠癯牥琠敢渠瑯氠獥桴湡㐠㔮‰杫愠摮映慲敭琠敢渠瑯氠獥桴湡㈠㜮‰杫愠数瑳湡慤摲搠獥杩غ㤱㜮ㄮ〰ㅸ〰洠楳敺倠琠灹ࡥ㤱㜮ㄮㄮ圀瑩敷汬戠牵瑮戠楲正ࡳ㤱㜮ㄮ㈮)圀瑩敓敷牢捩獫挠湯潦浲湩潴䤠⁓›㠴㔸⸹⸷ᤲ㔱‰⁸〱‰浭猠穩⁐祴数㤱㜮㈮ㄮ⸹⸷⸲⤲楗桴猠睥牥戠楲正潣普牯業杮琠卉㨠㐠㠸ص㤱㜮㌮〸ㅸ〵洠楳敺倠琠灹ࡥ㤱㜮㌮ㄮ⸹⸷⸳�牐癯摩湩湡慬楹杮渠湯牰獥畳敲丠㉐挠慬獳⠠楬桧⁴畤祴 ⹒⹃⹃瀠灩獥眠瑩潣汬牡潪湩整楷桴猠楴晦洠硩畴敲漠散敭瑮洠牯慴湩琠敨瀠潲潰瑲潩景ㄠ㈺⠠‱散敭瑮㨠㈠猠湡⥤椠据畬楤杮琠獥楴杮漠潪湩獴攠捴潣灭敬整㨠⸹⸸ᜱ〱‰浭搠慩⹒⹃⹃瀠灩٥㤱㠮㈮〵洠楤删䌮䌮楰数⸹⸸ᜳ㔲‰浭搠慩⹒⹃⹃瀠灩٥㤱㠮㐮㌀〰洠楤删䌮䌮楰数⸹⸸᜵㔴‰浭搠慩⹒⹃⹃瀠灩٥㤱㠮㘮㔀〰洠楤删䌮䌮楰数⸹⸸〶‰浭搠慩⹒⹃⹃瀠灩剥潃獮牴捵楴杮戠楲正洠獡湯祲洠湡潨敬椠散敭瑮洠牯慴㨱‴⠠ㄠ挠浥湥⁴›‴慳摮⤠删䌮䌮潴⁰汳扡眠瑩敃敭瑮䌠湯牣瑥㨱㨲‴業⁸⠠‱散敭瑮㨠㈠†猠湡›‴牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩⥥潦湵慤楴湯挠湯牣瑥㨱㨲‴業⁸⠠‱散敭瑮†›′慳摮㨠㐠朠慲敤瑳湯条牧来瑡〲浭渠浯湩污猠穩⥥椠獮摩汰獡整楲杮ㄠ洲桴捩楷桴挠浥湥⁴潭瑲牡ㄠ㌺⠠‱散敭瑮㨠㌠猠湡⥤映湩獩敨楷桴映潬瑡湩潣瑡漠敮瑡挠浥湥⁴湡慭楫杮挠慨湮汥湩挠浥湥⁴潣据敲整ㄠ㈺㐺⠠‱散敭瑮㨠㈠猠湡›‴牧摡摥猠潴敮愠杧敲慧整㈠洰潮業慮楳敺 楦楮桳摥眠瑩汦慯楴杮挠慯⁴景渠慥⁴散敭瑮挠浯汰瑥獡瀠牥猠慴摮牡敤楳湧⸹⸹�湉楳敤猠穩〹㡸‰浣愠摮㐠‵浣搠敥⁰湩汣摵湩⹃⹉挠癯牥眠瑩牦浡氨杩瑨搠瑵⥹㐠㔵㙸〱洠湩整湲污搠浩湥楳湯潴慴敷杩瑨漠潣敶湡牦浡潴戠潮⁴敬獳琠慨㠳欠眨楥桧⁴景挠癯牥㈠″杫愠摮眠楥桧⁴景映慲敭ㄠ‵杫 ࠺㤱㤮ㄮㄮ⸹⸹⸱ز㤱㤮㈮Û䤀獮摩楳敺ㄠ〲㥸‰浣愠摮㤠‰浣搠敥⁰湩汣摵湩⹃⹉挠癯牥眠瑩牦浡洨摥畩畤祴 〵‰浭椠瑮牥慮楤浡瑥牥潴慴敷杩瑨漠潣敶湡牦浡潴戠潮⁴敬獳琠慨ㄱ‶杫⠠敷杩瑨漠潣敶㠵欠湡敷杩瑨漠牦浡㠵欠⥧㨠⸹⸹⸲࠱㤱㤮㈮㈮⸹⸹�湉楳敤猠穩㈱砰〹挠湡〹挠敤灥椠据畬楤杮䌠䤮潣敶楷桴映慲敭⠠敨癡⁹畤祴 㘵‰浭椠瑮牥慮楤浡瑥牥潴慴敷杩瑨漠潣敶湡牦浡潴戠潮⁴敬獳琠慨〲‸杫⠠敷杩瑨漠潣敶〱‸杫愠摮眠楥桧⁴景映慲敭ㄠ〰欠⥧㨠⸹⸹⸳࠱㤱㤮㌮㈮䔀瑸慲映牯搠灥桴映牯洠湡潨敬ݳ㤱ㄮ⸰റ楓敺㤠砰〸挠७㤱ㄮ⸰⸱ऱ㤱ㄮ⸰⸱ܲ㤱ㄮ⸰า楓敺ㄠ〲㥸‰浣 ⸹〱㈮ㄮ ⸹〱㈮㈮ɯ䌀湯瑳畲瑣湩牢捩慭潳牮⁹楣捲汵牡琠灹慭桮汯⸰ㄹ湩整湲污搠慩愠⁴潢瑴浯愠摮〠㔮洶搠慩愠⁴潴⁰湩挠浥湥⁴潭瑲牡ㄠ㐺⠠‱散敭瑮㨠㐠猠湡⥤湩楳敤挠浥湥⁴汰獡整㈱洠桴捩楷桴挠浥湥⁴潭瑲牡ㄠ㌺⠠‱散敭瑮㨠㌠猠湡⥤映湩獩敨楷桴愠映潬瑡湩潣瑡漠敮瑡挠浥湥ⱴ映畯摮瑡潩潣据敲整ㄠ㌺㘺洠硩⠠‱散敭瑮㨠㌠猠湡›‶牧摡摥猠潴敮愠杧敲慧整㐠洰潮業慮楳敺Ⱙ愠摮洠歡湩敮散獳牡⁹档湡敮湩挠浥湥⁴潣据敲整†㨱㨲‴ㄨ挠浥湥⁴›′慳摮㨠㐠朠慲敤瑳湯条牧来瑡〲洠潮業慮楳敺 湩汣摵湩散瑮牥湩桳瑵整楲杮愠汬挠浯汰瑥⠠潆瑯爠獥獴愠摮ㄠ洲桴捩散敭瑮瀠慬瑳牥愠⁴桴硥整湲污猠牵慦散猠慨汬戠慰摩映牯猠灥牡瑡汥⥹㨠⸹ㄱㄮ⸹ㄱ㈮Z䔀瑸慲搠灥桴映牯挠物畣慬祴数洠湡潨敬〠㤮洱椠瑮牥慮楤愨⁴潢瑴浯 敢潹摮〠㤮洱琠⸱㜶ݭ㤱ㄮ⸲ܱ㤱ㄮ⸲☲楗桴匠睥牥戠楲正潣普牯業杮䤠⁓›㠴㔸Ȝ䌀湯瑳畲瑣湩牢捩慭潳牮⁹楣捲汵牡洠湡潨敬ㄠ㈮洲椠瑮牥慮楤瑡戠瑯潴湡⸰㘵楤瑡琠灯椠散敭瑮洠牯慴㨱‴ㄨ挠浥湥⁴㐺猠湡⥤椠獮摩散敭瑮瀠慬瑳牥ㄠ洲桴捩楷桴挠浥湥⁴潭瑲牡ㄠ㌺⠠‱散敭瑮㨠″慳摮 楦楮桳摥眠瑩汦慯楴杮挠慯⁴景渠慥⁴散敭瑮映畯摮瑡潩潣据敲整ㄠ㌺㘺⠠‱散敭瑮㨠㌠猠湡›‶牧摡摥猠潴敮愠杧敲慧整㐠洰潮業慮楳敺 湡慭楫杮渠捥獥慳祲挠慨湮汥椠散敭瑮挠湯牣瑥㨱㨲‴湩汣摵湩散瑮牥湩桳瑵整楲杮愠汬挠浯汰瑥⠠潆瑯爠獥獴愠摮ㄠ′浭琠楨正挠浥湥⁴汰獡整瑡琠敨攠瑸牥慮畳晲捡桳污敢瀠楡潦敳慰慲整祬ܩ㤱ㄮ⸳ܱ㤱ㄮ⸳帲硅牴敤瑰潦楣捲汵牡琠灹慭桮汯⸱㈲湩整湲污搠慩⠠瑡戠瑯潴⥭戠祥湯⸱㠶洠琠⸲㤲洠㨠⸹㐱ㄮ⸹㐱㈮ȧ䌀湯瑳畲瑣湩牢捩慭潳牮⁹楣捲汵牡洠湡潨敬ㄠ㔮′湩整湲污搠慩愠⁴潢瑴浯愠摮〠㔮‶楤瑡琠灯椠散敭瑮洠牯慴㨱‴ㄨ挠浥湥⁴›‴慳摮 湩楳敤挠浥湥⁴汰獡整㈱浭琠楨正眠瑩散敭瑮洠牯慴㨱″ㄨ挠浥湥⁴›″慳摮 楦楮桳摥眠瑩汦慯楴杮挠慯⁴景渠慥⁴散敭瑮潦湵慤楴湯挠湯牣瑥㨱㨳‶ㄨ挠浥湥⁴›″慳摮㨠㘠朠慲敤瑳湯条牧来瑡〴浭渠浯湩污猠穩⥥愠摮洠歡湩敮散獳牡⁹档湡敮湩挠浥湥⁴潣据敲整ㄠ㈺㐺⠠‱散敭瑮㨠㈠猠湡›‴牧摡摥猠潴敮愠杧敲慧整㈠洰潮業慮楳敺 楦楮桳摥眠瑩汦慯楴杮挠慯⁴景渠慥⁴散敭瑮愠汬挠浯汰瑥獡瀠牥猠慴摮牡敤楳湧㨠⸹㔱ㄮƨ㈀㌮洰搠敥⁰楷桴匠剆⁃潃敶湡牦浡栨慥祶搠瑵⁹䑈㈭‰牧摡敤楳湧瑡潩⥮㔠〶浭椠瑮牥慮楤浡瑥牥挠湯潦浲湩潴䤠匮㈱㤵ⰲ琠瑯污眠楥桧⁴漠潣敶湡牦浡潴戠潮⁴敬獳琠慨㠱′杫楦數湩挠浥湥⁴潣据敲整ㄠ㈺㐺⠠‱散敭瑮㨠㈠猠湡›‴牧摡摥猠潴敮愠杧敲慧整㈠洰潮業慮楳敺 湩汣摵湩散瑮牥湩桳瑵整楲杮愠汬挠浯汰瑥⠠潆瑯爠獥獴愠摮ㄠ′浭琠楨正挠浥湥⁴汰獡整瑡琠敨攠瑸牥慮畳晲捡桳污敢瀠楡潦敳慰慲整祬 ऺ㤱ㄮ⸵⸱ऱ㤱ㄮ⸵⸱唲硅牴敤瑰潦楣捲汵牡琠灹慭桮汯⸱㈵洠椠瑮牥慮楤愨⁴潢瑴浯 敢潹摮㈠㌮‰ܺ㤱ㄮ⸶ܱ㤱ㄮ⸶뼲牐癯摩湩⹍⹓映潯⁴敲瑳湩汣摵湩楦楸杮椠慭桮汯獥眠瑩〲㉸砰〱挠散敭瑮挠湯牣瑥汢捯獫ㄠ㌺㘺⠠‱散敭瑮㨠㌠猠湡›‶牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩⥥愠数瑳湡慤摲搠獥杩ܺ㤱ㄮ⸷ᠱ楗桴㈠砰〲洠煳慵敲戠牡⸹㜱㈮圀瑩〲洠楤浡瑥牥爠畯摮戠牡ɑ倀潲楶楤杮漠慲杮潣潬牵猠晡瑥⁹潦瑯爠獥⁴景洠 metre 1260
431 9.22 nimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.ÌReplacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size):19.19.119.19.2<Supplying and fixing C.I. cover without frame for manholes :19.20.1a455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.19.20.2[500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg.19.20.3\560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg.nProviding and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality19.21.1Light duty D- 2.5 19.21.1.1/Rectangular shape 600x450mm internal dimensions 19.21.1.2&Square shape 450mm internal dimensions 19.21.1.3&Circular shape 450mm internal diameter19.21.2Medium duty - 10 19.21.2.1%Square shape 450mm internal dimension 19.21.2.2&Circular shape 500mm internal diameter19.21.3Heavy duty D - 20 19.21.3.1'Circular shape 560 mm internal diameter19.21.4Extra Heavy Duty - 35 19.21.4.1#Circular shape 560 mm internal dia.Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg.Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :19.23.1 For pipes 100 to 230 mm diameter19.23.2 For pipes 250 to 300 mm diameter19.23.3 For pipes 350 to 450 mm diameteréProviding sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with cement mortar 1:1 (1 cement : 1 sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications :19.24.1*100 mm dia. sand cast iron drop connection19.24.2*150 mm dia. sand cast iron drop connectionJExtra for depths beyond 60 cm of sand cast iron drop connection complete :19.25.1.For 100 mm dia. sand cast iron drop connection19.25.2.For 150 mm dia. sand cast iron drop connectionÃRaising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Brick work for Raising depth of manhole to be paid separately) :19.26.1PRectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.519.26.2MRectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 1019.26.3MRectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 2019.26.4[Circular manhole 140 cm dia with circular cover 600 mm dia of grade Extra heavy duty HD -35ÑConstructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design :19.27.119.27.2(With fly ash bricks 100 key/c
瑩慭桮汯潣敶楷桴映慲敭漠汣慥灯湥湩楳敺㐠〵㙘〰浭爠捥慴杮汵牡栠癡湩敷杩瑨漠挨浯汰瑥湵瑩 眨楥桧⁴景映慲敭ㄠ㠮欴敷杩瑨漠潣敶㐱㈮杫넠ㄠ┰ 䰨⽄⸲䴵⥔栠癡湩潬摡戠慥楲杮挠灡捡瑩⁹倨楯瑮氠慯⸲䴵⥔愠数整瑳湩潣敤䈠䕓⁎㈱㨴㤱㐹慨楶杮氠晩楴杮愠牲湡敧敭瑮猠潨汵慨敶愠湩敳瑲潩景㔠浭搠畯汢敳污摥挠潬敳敫⁹潨敬愠摮栠杩瑳敲杮桴瀠慬瑳捩愠汬祯猯慴湩敬獳猠整汥猠捯敫整牡慲杮浥湥ǀ匀灵汰楹杮愠摮映硩湩景䘠偒䜯偒挠浯潰楳整洠湡潨敬挠癯牥眠瑩牦浡景挠敬牡漠数楮杮猠穩〳堰〳洰猨畱牡⥥栠癡湩敷杩瑨漠挨浯汰瑥湵瑩 眨楥桧⁴景映慲敭ㄠㄮ欲敷杩瑨漠潣敶⸴欱₱〱⤥⠠䑌㈯㔮呍 慨楶杮氠慯敢牡湩慣慰楣祴⠠潐湩⁴潬摡㈠㔮呍 獡瀠牥琠獥楴杮挠摯卂久ㄠ㐲ㄺ㤹⸴栠癡湩楬瑦湩牡慲杮浥湥⁴桳畯摬栠癡湡椠獮牥楴湯漠洵潤扵敬猠慥敬汣獯摥欠祥栠汯湡楨桧猠牴湥瑧汰獡楴污潬⽹瑳楡汮獥瑳敥潳正瑥摥愠牲湡敧敭瑮밮畓灰祬湩湡楦楸杮漠剆⽐則⁐潣灭獯瑩慭桮汯潣敶楷桴映慲敭漠汣慥灯湥湩楳敺㘠〰浭⠠潲湵⥤栠癡湩敷杩瑨漠挨浯汰瑥湵瑩 眨楥桧⁴景映慲敭ㄠ⸳欶敷杩瑨漠潣敶㌴ㄮ杫⬠ⴠㄠ┰ 䠨⽄㔲呍 慨楶杮氠慯敢牡湩慣慰楣祴⠠潐湩⁴潬摡㈠䴵⥔愠数整瑳湩潣敤䈠䕓⁎㈱㨴㤱㐹慨楶杮氠晩楴杮愠牲湡敧敭瑮猠潨汵慨敶愠湩敳瑲潩景㔠洠潤扵敬猠慥敬汣獯摥欠祥栠汯湡楨桧猠牴湥瑧汰獡楴污潬⽹瑳楡汮獥瑳敥潳正瑥摥愠牲湡敧敭瑮ƻ匀灵汰楹杮愠摮映硩湩景䘠偒䜯偒挠浯潰楳整洠湡潨敬挠癯牥眠瑩牦浡景挠敬牡漠数楮杮猠穩〵洰爨畯摮 慨楶杮眠楥桧⁴景⠠潣灭敬整甠楮⥴⠠敷杩瑨漠牦浡ㄱ㈮杫⬠眠楥桧⁴景挠癯牥㐠⸱㠷杫†₱〱⤥⠠䑈㈯䴵⥔栠癡湩潬摡戠慥楲杮挠灡捡瑩⁹倨楯瑮氠慯㔲呍 獡瀠牥琠獥楴杮挠摯卂久ㄠ㐲ㄺ㤹⸴䠠癡湩楬瑦湩牡慲杮浥湥⁴桳畯摬栠癡湡椠獮牥楴湯漠洵潤扵敬猠慥敬汣獯摥欠祥栠汯湡楨桧猠牴湥瑧汰獡楴污潬⽹瑳楡汮獥瑳敥潳正瑥摥愠牲湡敧敭瑮B䐀摥捵⁴潦潮⁴牰癯摩湩湡湩瑳污楬杮䘠偒䜯偒洠湡潨敬挠癯牥猠穩ݥ㤱㐮⸵⬱〹洰硭㔴洰眨楥桧⁴景挠癯牥㐠⸳㘷杫넠ㄠ┰ܩ㤱㐮⸵⨲㔴洰硭〶洰眨楥桧⁴景挠癯牥ㄠ⸴欲₱〱⤥⸹㔴㌮)㌀〰浭㍸〰浭⠠敷杩瑨漠潣敶⸴欱₱〱⤥⸹㔴㐮%㘀〰浭⠠敷杩瑨漠潣敶ㄴ㜮欸₱〱⤥⸹㔴㔮$㔀〰浭⠠敷杩瑨漠潣敶㌴ㄮ杫넠ㄠ┰椩牐癯摩湩Ɽ氠祡湩湡潪湩楴杮䠠偄⁅潄扵敬圠污潣牲杵瑡摥⠠坄⥃瀠灩獥⠠硥慣慶楴湯琠敢瀠楡敳数慲整祬ܩ㤱㐮⸶ᠱ〱‰浭搠慩琠ㄱ‰浭搠慩⸹㘴㈮〵洠楤潴ㄠ〶洠楤ݡ㤱㐮⸶ܳ㤱㐮⸶ܴ㤱㐮⸶ଵ牐癯摩湩湡楦楸杮愠畬業楮浵眠牯潦潤牯ⱳ眠湩潤獷敶瑮汩瑡牯湡慰瑲瑩潩獮眠瑩硥牴摵摥戠極瑬甠⁰瑳湡慤摲琠扵汵牡猠捥楴湯⽳愠灰潲牰慩整娠猠捥楴湯湡瑯敨敳瑣潩獮漠灡牰癯摥洠歡潣普牯業杮琠卉›㌷″湡卉›㈱㔸楦楸杮眠瑩慤桳映獡整敮獲漠敲畱物摥搠慩愠摮猠穩ⱥ椠据畬楤杮渠捥獥慳祲映汩楬杮甠⁰桴慧獰愠⁴番据楴湯ⱳ椠攮瑡琠灯潢瑴浯愠摮猠摩獥眠瑩敲畱物摥䔠䑐⁍畲扢牥 敮灯敲敮朠獡敫⁴瑥䄠畬業楮浵猠捥楴湯桳污敢猠潭瑯ⱨ爠獵⁴牦敥瑳慲杩瑨業牴摥愠摮樠楯瑮摥洠捥慨楮慣汬⁹桷牥癥牥爠煥極敲湩汣摵湩汣慥⁴湡汧ⱥ䄠畬業楮浵猠慮⁰敢摡湩潦汧穡湩 慰敮楬杮⹃⹐戠慲獳⼠猠慴湩敬獳猠整汥猠牣睥ⱳ†污潣灭敬整愠数牡档瑩捥畴慲牤睡湩獧愠摮琠敨搠物捥楴湯景䔠杮湩敥湩挭慨杲⠠汇穡湩Ⱨ瀠湡汥湩湡慤桳映獡整敮獲琠敢瀠楡潦敳慰慲整祬 غㄲㄮㄮ䘀牯映硩摥瀠牯楴湯ㄲㄮㄮㄮ䄀潮楤敳污浵湩畩愨潮楤敳牴湡灳牡湥⁴牯搠敹潴爠煥極敲桳摡捡潣摲湩潴䤠㩓ㄠ㘸ⰸ䴠湩浩浵愠潮楤潣瑡湩景朠慲敤䄠ㅃ⤵㈀⸱⸱⸱䜲潐摷牥挠慯整污浵湩畩洨湩浩浵琠楨正敮獳漠潰摷牥挠慯楴杮㔠‰業牣湯ࠩㄲㄮㄮ㌮\倀汯敹瑳牥瀠睯敤潣瑡摥愠畬業楮浵⠠業楮畭琠楨正敮獳漠潰祬獥整潰摷牥挠慯楴杮㔠‰業牣湯ةㄲㄮ㈮ĕ䘀牯猠畨瑴牥景搠潯獲楷摮睯湡敶瑮汩瑡牯湩汣摵湩牰癯摩湩湡楦楸杮栠湩敧⽳瀠癩瑯湡慭楫杮瀠潲楶楳湯映牯映硩湩††漠††映瑩楴杮†眠敨敲敶敲畱物摥†椠据畬楤杮†琠敨†挠獯⁴†景䔠䑐⁍畲扢牥⼠渠潥牰湥慧歳瑥爠煥極敲䘨瑩楴杮桳污敢瀠楡潦敳慰慲整祬⸩㈀⸱⸱⸲࠱ㄲㄮ㈮㈮㈀⸱⸱⸲سㄲㄮ㌮A䐀摥捵⁴潦潮⁴牰癯摩湩䑅䵐爠扵敢⽲敮灯敲敮朠獡敫⁴污愠潲湵ť倀潲楶楤杮愠摮映硩湩㈱浭琠楨正倠敲氭浡湩瑡摥瀠牡楴汣潢牡汦瑡瀠敲獳摥琠牨敥氠祡牥漠牧摡摥眠潯慰瑲捩敬戠慯摲挠湯潦浲湩琠卉›㈱㈸″片摡祔数氠ⱬ椠慰敮汬湩楦數湩愠畬業楮浵搠潯獲楷摮睯桳瑵整獲愠摮瀠牡楴楴湯映慲敭楷桴䌠倮牢獡 瑳楡汮獥瑳敥捳敲獷攠捴潣灭敬整愠数牡档瑩捥畴慲牤睡湩獧愠摮搠物捥楴湯景攠杮湩敥湩挭慨杲㈀⸱⸲欱牐ⵥ慬業慮整慰瑲捩敬戠慯摲眠瑩敤潣慲楴敶氠浡湩瑡潩湯漠敮猠摩湡慢慬据湩慬業慮楴湯漠瑯敨楳敤خㄲ㈮㈮F倀敲氭浡湩瑡摥瀠牡楴汣潢牡楷桴搠捥牯瑡癩慬業慮楴湯漠潢桴猠摩獥ᨮ牐癯摩湩湡楦楸杮朠慬楺杮椠污浵湩畩潤牯楷摮睯敶瑮汩瑡牯猠畨瑴牥湡慰瑲瑩潩獮攠捴楷桴䔠䑐⁍畲扢牥 敮灯敲敮朠獡敫⁴瑥挠浯汰瑥獡瀠牥琠敨愠捲楨整瑣牵污搠慲楷杮湡桴楤敲瑣潩獮漠湥楧敮牥椭档牡敧䌨獯⁴景愠畬業楮浵猠慮⁰敢摡湩桳污敢瀠楡湩戠獡捩椠整⥭㨠㈀⸱⸳䬱楗桴映潬瑡朠慬獳瀠湡獥漠⸴‰浭琠楨正敮獳⠠敷杩瑨渠瑯氠獥桴湡ㄠ‰杫猯浱ةㄲ㌮㈮O圀瑩汦慯⁴汧獡慰敮景㔠〮洠桴捩湫獥眨楥桧⁴潮⁴敬獳琠慨㈱㔮‰杫猯浱⤠㈀⸱⸳䬳楗桴映潬瑡朠慬獳瀠湡獥漠‸浭琠楨正敮獳⠠敷杩瑨渠瑯氠獥桴湡㈠‰杫猯浱⤠䤮摁硥牴潦牰癯摩湩湡映硩湩牦慯瑳摥朠慬獳椠獮整摡漠汦慯⁴汧獡ٳㄲ㐮ㄮE圀瑩汧獡慰敮景㐠〮洠桴捩湫獥眨楥桧⁴潮⁴敬獳琠慨〱欠⽧煳⥭㈀⸱⸴䤲楗桴朠慬獳瀠湡獥漠⸵‰浭琠楨正敮獳⠠敷杩瑨渠瑯氠獥桴湡ㄠ⸲〵欠⽧煳ةㄲ㐮㌮E圀瑩汧獡慰敮景㠠洠桴捩湫獥眨楥桧⁴潮⁴敬獳琠慨〲欠⽧煳⸩Ȇ倀潲楶楤杮愠摮映硩湩搠畯汢捡楴湯栠摹慲汵捩映潬牯猠牰湩景愠灰潲敶牢湡湡慭畮慦瑣牵潣普牯業杮琠卉㨠㘠ㄳⰵ栠癡湩牢湡潬潧攠扭獯敳湯琠敨†潢祤⼠汰瑡楷桴搠畯汢灳楲杮洠捥慨楮浳愠摮搠潯敷杩瑨甠瑰㈱‵杫Ⱞ映牯搠潯獲湩汣摵湩潣瑳漠挠瑵楴杮†汦潯獲Ⱐ攠扭摥楤杮椠汦潯獲愠敲畱物摥愠摮洠歡湩潧摯琠敨猠浡慭捴楨杮琠桴硥獩楴杮映潬牯映湩獩楨杮愠摮挠癯牥瀠慬整楷桴戠慲獳瀠癩瑯愠摮猠湩汧楰捥⹍⹓猠敨瑥漠瑵牥戠硯眠瑩汳摩汰瑡瑥挠浯汰瑥獡瀠牥琠敨搠物捥楴湯漠湅楧敮牥椭档牡敧㨠ؠㄲ㔮ㄮ<圀瑩瑳楡汮獥瑳敥潣敶汰瑡業楮畭⸱㔲洠桴捩湫獥ٳㄲ㔮㈮3圀瑩牢獡潣敶汰瑡業楮畭⸱㔲洠桴捩湫獥ʲ倀潲楶楤杮愠摮映硩湩潰摷牥挠慯整污浵湩畩潷歲⠠業楮畭桴捩湫獥景瀠睯敤潣瑡湩〵洠捩潲⥮挠湯楳瑳湩景琠敥 湡汧敳瑣潩獮景愠灰潲敶慭敫挠湯潦浲湩潴䤠⁓›㌷″湩映慲敭景映污敳挠楥楬杮椠据畬楤杮愠畬業楮浵愠杮敬挠敬瑡楷桴渠捥獥慳祲䌠倮牢獡⽳猠慴湩敬獳猠整汥猠湵捳敲獷污浵湩畩数楲敭整湡汧獥映硩摥琠慷汬眠瑩瑳楡汮獥瑳敥慲汷瀠畬獧䀠㐠〵洠散瑮敲琠散瑮敲愠摮映硩湩桴牦浡潷歲琠⹇⹉氠癥汥愠橤獵楴杮栠湡敧獲㘠洠楤眠瑩敮散獳牡⁹慣浤畩汰瑡摥洠捡楨敮猠牣睥污潣灭敬整愠数灡牰癯摥愠捲楨整瑣牵污搠慲楷杮湡楤敲瑣潩景琠敨䔠杮湩敥湩挭慨杲氨癥汥愠橤獵楴杮栠湡敧獲散汩湩汣慥獴愠摮攠灸湡楳湯栠汯慦瑳湥牥潴戠慰摩映牯猠灥牡瑡汥⥹㼮牐癯摩湩愠摮†楦楸杮†‶洠搠慩⹇⹉氠癥汥愠橤獵楴杮栠湡敧獲⠠灵潴ㄠ〲洰敬杮桴Ⱙ映硩摥琠潲景猠慬獢戠⁹敭湡景挠楥楬杮挠敬瑡慭敤漠瑵漠⹇⹉映慬⁴〴㍸浭猠穩〶洠潬杮愠摮猠慴湩敬獳猠整汥攠灸湡慤汢慤桳映獡整敮景ㄠ⸲‵浭††楤†愠摮††〵††浭††潬杮潣灭敬整愠数楤敲瑣潩景䔠杮湩敥椭档牡敧缮牐癯摩湩湡楦楸杮洠捡楨敮洠畯摬摥愠畬業楮浵挠癯牥湩景愠灰潲敶慰瑴牥湡敤楳湧慭敤漠瑵漠慭档湩畣⁴污浵湩畩桳敥⁴湡慭档湩潨敬潦敲散癩湩慤桳映獡整敮Ⱳ漠敶硥慰獮潩潪湩獴漠敶瑲捩污猠牵慦散⽳散汩湩汦潯獲桴楦楸杮漠汰瑡湩漠敮爠睯漠湯楳敤漠潪湩⁴湯祬猠慨汬戠潤敮眠瑩瑳楡汮獥瑳敥慤桳映獡整敮獲漠‸浭搠慩愠摮㜠‵浭氠湯潢瑬椠据畬楤杮瀠潲楶楤杮愠畬業楮浵眠獡敨獲㈠洠桴捩湡㔱洠楤ⱡ愠⁴瑳条敧敲楰捴景†〲洰散瑮敲琠散瑮敲椠据畬楤杮搠楲汬湩潨敬湩琠敨爠捥楥楶杮猠牵慦散愠摮瀠潲楶楤杮攠灸湡慤汢汰獡楴汳敥敶湩栠汯獥攠捴潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲غㄲ㠮ㄮ䄀潮楤敳污浵湩畩桳敥⁴⸲洵桴捩愨潮楤敳牴湡灳牡湥⁴牯搠敹潴爠煥極敲桳摡捡潣摲湩潴䤠㩓ㄠ㘸ⰸ䴠湩浩浵愠潮楤潣瑡湩景朠慲敤䄠⁃㔱ةㄲ㠮㈮Y倀睯敤潣瑡摥愠畬業楮浵猠敨瑥㈠㔮浭琠楨正⠠業楮畭桴捩湫獥景瀠睯敤潣瑡湩〵洠捩潲⥮Ă䘀汩楬杮琠敨朠灡椠敢睴敥污浵湩畩牦浡湡摡慪散瑮删䍃 牂捩⽫匠潴敮眠牯祢瀠潲楶楤杮眠慥桴牥猠汩捩湯猠慥慬瑮漠敶慢正牥爠摯漠灡牰癯摥焠慵楬祴愠数牡档瑩捥畴慲牤睡湩獧愠摮搠物捥楴湯漠湅楧敮牥椭档牡敧挠浯汰瑥唠瑰‵浭搠灥桴愠摮㔠洠楷瑤녨硅牴潦灡汰楹杮愠摤瑩潩慮湡摯捩†潣瑡湩䄠⁃㈠‵椠獮整摡漠䍁†ㄠ‵†潴†愠畬業楮浵†硥牴摵摥猠捥 ions. For fixed portion & for shutters of doors, windows and ventilatorsProviding and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.ªProviding and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and length as required with SS screws etc complete as per direction of Engineer-in-Charge.21.12.1.Anodized (AC 15 ) aluminium tubular handle bar21.12.2GPowder coated minimum thickness 50 micron aluminium tubular handle bar.21.12.3QPolyester powder coated minimum thickness 50 micron aluminium tubular handle bar.ÍProviding and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.21.15.1Anodized (AC15) aluminium21.15.24Powder coated minimum thickness 50 micron aluminium.21.15.3?Polyester powder coated minimum thickness 50 micron aluminium.Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-Charge21.16.1Anodized (AC15 ) aluminium21.16.23Powder coated minimum thickness 50 micron aluminium21.16.31Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge. (Only ,weight of grill to be measured for payment).Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately).ÏProviding and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make.¹Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make.ÁProviding and fixing 25 micron thick Non reflective heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in- charge of approved brand and make.³Providing and fixing 12 mm thick toughened glass including all connectors and fixing accessories all complete for partitions, cubicals etc. As per direction of Engineer-in-Charge.¿Providing and fixing 12mm thick toughened glass railing complete height of 1400mm with top 50m X 50mm teak wood hand railing finish with PU polish glass fitted with 45 mm dia SS glass holdingmetere=Extra for froasted glass (with eching film) in item No. 21.22Providing, section design pattern and fixing/installation of mil finish powder coated System aluminum partition/door/windows outer frame and shutter sections use(The profile should be of alloy 6063 T6 and dimensional tolerance should be within the limit specified in EN 12020) infill glass Dgu-5 mm ctg+ 1Omm Air gap +5 mm ctg-1,5 for shutter pleated mesh use for fittings Handle, ( Casement for double side door handle)Locking system (MVD Locking), hinge type (Door hinges)All hardware and accessories fitted must have corrosion protection to met requirement of minimum 480 hours of salt spray test as per ASTMB117. The drainage system should be built in to the 1.0 system with drainage cap equipped with non return valve. The wool pile should be enhanced with silent fin. Corner joints should mandatorily have spring loaded corner cleats to provide added strength to the corner. All accessories essential for smooth performance, durability should be used in line system . Product should have manufacturer and installation warranty of at least 10 years. All work complete as per directed by the Architect Engineer in-Charge Note:- After fixing the outer frame, the gap between frame and adjacent finish walls shall be filled with weather proof neutral cure silicon sealant on outside as well as inside with backer rod to provide the essential control of sealant depth and two sided adhesion of sealant. 21.25.1 3000X2600 mm21.25.2 3000X2400mm21.25.3 1200X2600mm21.25.4 1200X2700mm21.25.5 4000X2600mm21.25.6 4900X2600mm21.25.7 1500X2600mm21.25.8 2000X2600mm21.25.9 2400X2700mm21.25.10 3500X2600mm21.25.1121.25.12Providing and fixing mill finish powder coated System Profile 10 mm thick toughened glass partition having system profile size (25X45mm) with every glass joint use I-Profile frame for glass partition, All work complete as per directed by the Architect/Engineer-in-Charge.Providing and fixing 10mm thick toughened glass railing of height up to 1200 mm with top 75mm X 50mm teak wood hand railing finish with PU polish glass fitted with45 mm dia SS glass holding studs all work complete as per directed by architect/engineer in charge.ìProviding and fixing 10mm thick toughened glass railing of height up to 1200 mm with top 50mm X 50mm S.S hand railing glass fitted with45 mm dia SS glass holding studs all work complete as per directed by architect/engineer- in -charge.Providing and fixing 12 mm thick toughened glass partition with patch fitting All work complete as per directed by the Architect/Engineer-in-Charge.ÊProviding and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge consisting of:(i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the levelling course ( levelling course to be bpaid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.(ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportions.EÂ(iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (with 5 years service guarantee) Using rough Kota stone.EÁProviding and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended pr sqm 1040
432 9.221 oportion complete at all levels and as directed by Engineer-in-charge (with 5 years service guarantee) Using rough Kota stone.Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :Îa) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.FE¿b) IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.FE`c) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area.FE¿d) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee)FEProviding and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete (with 5 years service guarantee)22.4.17Serrated with central bulb (225mm wide, 8- 11mm thick).22.4.24Dumb bell with central bulb (180mm wide, 8mm thick).22.4.3 Kickers (320mm wide, 5mm thick).³Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.FE[b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.FEProviding and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying :a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.FEb) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.FEdc) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around.FEÄProviding and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.FE!b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.FEÇc) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep.Pe) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge: (with 5 years service guarantee) With average thickness of 120mm and minimum thickness at khurra as 65 mm. wProviding and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic decimeter per square metre including preparation of surface but excluding grading complete with : (with five years service gurantee). Bitumen felt (hessian base) type 3 grade I conforming to IS: 1322.¸Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of µstone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee).Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6cu.dm per sqm including preparation of surface, excluding grading, complete. (With five years service gurantee).+Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blow or/ and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee)Deduct for omitting in water proofing treatment final course of spreading stone grit 6mm down size or pea sized gravel at 6 cudm per sqm.8Grading roof for receiving water proofing treatment withWCement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size)0Providing and laying insitu six course water proofing treatment with APP (Atactic poly- propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm,conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. (with 5 years service guarantee))Providing and layi metre 1260
433 9.222 ng in situ four course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with 5 years service guarantee).4Providing and laying in situ six course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with five years service gurantee).mProviding and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2mm thick water proofing membrane for corrugated roof sheets, black finished reinforced with glass fibre matt consisting in longitudinal and transverse direction at 23°C as 350/300 N/ 5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. (With five years service gurantee).Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer of the membrane shall be as under:Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (with 5 years service guarantee)Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: (with 5 years service guarantee).2 (i) Surface preparation roughening of surface, opening cracks in V groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely.FE(ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). F E!D#E¬(iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area.T(iv) The treated area should be cure with water for 48 hrs. by flooding the surface.|(v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee)v(i)Removal of damaged waterproofing treatment if any like bituminous membrane / plaster/ brick bat koba/screeding etc.E(ii) Surface preparation: Roughening of surface by scrubbing with steel wire/ Nylon brush/ Removing all dust particles and washing with adequate water to clean completely, opening of cracks in 'V' groove in size of 5mm x 10m (WxD), filling of cracks with elastomeric creak filler/PU sealent repair of potholes and holor making on roof surface by polymer mortar with adding SBR bonding agent.(iii) Providing and applying 1st coating of rubberized elastomeric liquid membrane as primer (ratio 1:2 1 part liquid membrane and 2 part water) by brush/ Roller/ Spray having minimum thickness of 70-80 micron. Allow the coating to set in natural air for minimum 2 hrs, then put reinforcement by laying 45gsm fibre glass mesh and applying 2nd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 20% water) with minimum thickness 100-120 micron. Allow the coating to set in natural air for minimum 12 hrs.÷(iv) Providing and applying 3rd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 10% water). Total DFT (Dry film thickness) thickness after 3rd coat must be 280-300 micron and consumption in three coats @ 6.5kg for 10sqm.ü(v) Providing and applying 4th and 5th coat of High quality waterproof membrane in white colour, single component special synthetic resin based flexible thixotropic white color coating with excellent UV resistance (SRI - 144) with more than 300% elongation (confirming ASTM D 412-98) in ratio: 1 part membrane and 10% water thickness of 200 micron DFT in two coats, with average consumption @ 5kg per 10 sqm. After application of fourth coat let it air dry for minimum 3 hrs before application of fifth coat.`(vi) The treated area must be tested for water leakage/seepage by flooding with water for 48 hrsa(vii) Application of membrane coating shall be got done by authorized applicator of manufacturer.(viii) 5 years of service guarantee to be provided. All above operations to be done in order as per direction on Engineer-in-Charge. ZSupplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure sqm 28929
434 9.223 猀 瀀攀爀 䐀䤀一 㐀㠀 猀琀愀渀搀愀爀搀猀Ⰰ 眀椀琀栀 攀 sqm 12719
ongation of 350% as per ASTM D412 & crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping a
435 9.224 nd properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge.ɕ匀灵汰楹杮愠摮愠灰祬湩睴潣灭湯湥⁴汥獡潴敭楲捡祲楬潰祬敭潭楤楦摥挠浥湥楴楴畯慷整灲潲景湩潣瑡湩Ⱨ栠癡湩〸‥汥湯慧楴湯愠数十䵔䐠ㄴⰲ爠獥獩楴杮㔠戠牡票潲瑳瑡捩瀠敲獳牵獡瀠牥䐠义ㄠ㐰ⰸ爠摥捵楴湯琠慲楰档潬楲敤猠慨汬戠〷愠数䥄⁎〱㠴牣捡牢摩楧杮甠瑰⸱洲獡瀠牥䄠呓⁍㔴㠴㔮桔潣瑡湩桳污慨敶映潯牧摡散瑲晩捩瑡牦浯氠扡牯瑡牯敩楬敫䌠呆䥒桔業楸杮爠瑡潩漠桴潣瑡湩桳污敢㈠瀠牡獴漠潰摷牥☠ㄠ瀠牡⁴景氠煩極楷桴畯⁴湡⁹慷整摡楤楴湯椠桴業楸杮瑥潣灭敬整愠数慭畮慦瑣牵牥灳捥晩捩瑡潩獮愠摮愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲̶倁爀漀瘀椀搀椀渀最 愀渀搀 愀瀀瀀氀礀椀渀最 唀嘀 匀琀愀戀氀攀 瀀漀氀礀甀爀攀琀栀愀渀攀 氀椀焀甀椀搀 眀愀琀攀爀 瀀爀漀漀昀椀渀最 洀攀洀戀爀愀渀攀 栀愀瘀椀渀最 匀甀渀 刀攀昀氀攀挀琀椀瘀椀琀礀 䤀渀搀攀砀 ⠀匀刀䤀⤀ 漀昀 㘀 漀渀 琀漀瀀 漀昀 挀漀渀挀爀攀琀攀 爀漀漀昀 ⼀ 刀攀琀愀椀渀渀椀渀最 眀愀氀氀 ⼀ 伀氀搀 氀愀礀攀爀 漀昀 戀椀琀甀洀椀渀漀甀猀 猀甀爀昀愀挀攀猀 ⼀ 倀漀氀礀甀爀攀琀栀愀渀攀 昀漀愀洀 愀渀搀 洀攀琀愀氀 猀甀爀昀愀挀攀猀 椀渀 琀栀爀攀攀 漀爀 洀漀爀攀 挀漀愀琀猀 䀀㈀ 欀最⼀ 猀焀洀 挀漀渀猀椀猀琀椀渀最 漀昀 愀 挀漀愀琀 漀昀 琀眀漀 挀漀洀瀀漀渀攀渀琀 攀瀀漀砀礀 瀀爀椀洀攀爀 椀渀 爀愀琀椀漀 漀昀 㨀㌀⠀漀渀攀 瀀愀爀琀 漀昀 爀攀猀椀渀 愀渀搀 ㌀ 瀀愀爀琀猀 漀昀 栀愀爀搀渀攀爀⤀ 愀琀 愀 挀漀渀猀甀洀瀀琀椀漀渀 漀昀 ㈀欀最⼀ 猀焀洀⸀ 琀栀攀 瘀椀琀愀氀 瀀栀礀猀椀挀愀氀 愀渀搀 挀栀攀洀椀挀愀氀 瀀愀爀愀洀攀琀攀爀猀 猀栀愀氀氀 戀攀 愀猀 甀渀搀攀爀 㨀 䴀椀渀 䔀氀漀渀最愀琀椀漀渀 愀琀 戀爀攀愀欀 漀昀 㘀 ─ 愀猀 瀀攀爀 䄀匀吀䴀 䐀㐀㈀ 愀渀搀 琀攀渀猀椀氀攀 猀琀爀攀渀最琀栀 漀昀 ㌀⸀ 一⼀洀洀㈀ 愀猀 瀀攀爀 䄀匀吀䴀 䐀㐀㈀⸀ 吀栀攀 漀瀀攀爀愀琀椀漀渀 猀栀愀氀氀 戀攀 挀愀爀爀椀攀搀 漀甀琀 愀昀琀攀爀 猀挀爀愀瀀瀀椀渀最 愀渀搀 瀀爀漀瀀攀爀氀礀 挀氀攀愀渀椀渀最 琀栀攀 猀甀爀昀愀挀攀 琀漀 爀攀洀漀瘀攀 氀漀漀猀攀 瀀愀爀琀椀挀氀攀猀 眀椀琀栀 眀椀爀攀 戀爀甀猀栀攀猀Ⰰ 挀漀洀瀀氀攀琀攀 椀渀 愀氀氀 爀攀猀瀀攀挀琀 愀猀 爀攀挀漀洀洀攀渀搀攀搀 戀礀 琀栀攀 洀愀渀甀昀愀挀琀甀爀攀爀ᤀ猠 猀瀀攀挀椀昀椀挀愀琀椀漀渀 愀渀搀 搀椀爀攀挀琀椀漀渀 漀昀 䔀渀最椀渀攀攀爀ⴀ椀渀ⴀ䌀栀愀爀最攀⸀䐀畓灰祬湩…湩瑳污楬杮眠瑡牥牰潯楦杮琠敲瑡敭瑮戠⁹獵湩⸱′浭琠楨正䠠偄⁅敭扭慲敮戠晥牯慣瑳湩景琠敨戠獡䍒⁃汳扡桔牰ⵥ灡汰敩敭扭慲敮朠瑥潢摮摥琠桴湵敤湲慥桴漠桴潰牵摥挠湯牣瑥獵摥愠慢敳猠慬吠敨洠浥牢湡桳污潣獮獩⁴景愠琠楨正䠠偄⁅楦浬楨桧祬†条牧獥楳敶瀠敲獳牵敳獮瑩癩摡敨楳敶愠摮眠慥桴牥爠獥獩楴杮挠慯楴杮眠楨档戠湯獤椠瑮来慲汬⁹潴瀠畯敲潣据敲整漠慢敳猠慬吠敨洠浥牢湡桳污潣普牯獭琠慢敳敭瑮眠瑡牥牰潯楦杮瀠潲整瑣潩潴朠慲敤ⰲ㌠☠㐠愠敤楦敮湩䈠⁓ㄸ㈰㈺〰⸹吠敨眠瑡牥牰潯楦杮洠浥牢湡桳污慨敶映汯潬楷杮洠湩浩浵瀠潲数瑲敩㩳PȈ愀ꀩꂠ删獥獩⁴票牤獯慴楴牰獥畳敲漠灵琠〷洠栠慥景眠瑡牥愠数十䵔䐠㌵㔸Ȼ䘀䔀㜀ࠀ⥢ꂠꂠ₠畐据畴敲删獥獩慴据景㤠〵丠⠠獡瀠牥䄠呓⁍ㅅ㐵ȩ䘀ࠀ䔀⼀ࠀ⥣ꂠꂠ₠汅湯慧楴湯漠㐾〰┠⠠獡瀠牥䄠呓⁍㑄㈱ȩ䘀ࠀ䔀㴀ࠀ⥤ꂠ₠敐汥匠牴湥瑧景挠湯牣瑥㩥㸠㔱〰丠洯⠠獡瀠牥䄠呓⁍㥄㌰ȩ䘀䔀㠀ࠀ⥥ꂠꂠ₠敔獮汩瑳敲杮桴漠㠲㈮䴠䅐⠠獡瀠牥䄠呓⁍㑄㈱⸩FEˍ倀潲楶楤杮愠摮愠灰祬湩⸲‰浭琠楨正琠楷潣潬牵映敬楸汢噐⁃慷整灲潲景湩敭扭慲敮汆硥扩汩瑩⁹湵敤潬⁷整灭牥瑡牵獥愠数久㐠㔹㔭猠潨汵敢㰠ⴠ㈠搰来⹃传污潨楲潺瑮污猠牵慦散敇瑯硥楴敬㌠〰䜠浳琠敢氠楡癯牥倠䍃桴湡氠祡湩噐⁃敭扭慲敮漠敶敇瑯硥楴敬愠摮琠敢猠慥敬楷桴栠瑯愠物眠汥楤杮洠瑥潨瑡愠汬樠楯瑮湡癯牥倠䍖洠浥牢湡牰癯摩〳‰獇䜠潥整瑸汩吠敨瀠潲整瑣潩猠牣敥†景猠極慴汢桴捩湫獥传污敶瑲捩污猠牵慦散敇瑯硥楴敬㌠〰䜠浳琠敢氠楡污湯楷桴嘠牥楴慣慷汬桴湡氠祡湩噐⁃敭扭慲敮漠敶敇瑯硥楴敬愠摮琠敢猠慥敬楷桴栠瑯愠物眠汥楤杮洠瑥潨瑡愠汬樠楯瑮湡癯牥倠䍖洠浥牢湡牰癯摩湩牰瑯捥楴湯氠祡牥漠牄楡潂牡䑈䕐䐠浩汰桳敥⁴敢潦敲戠捡楦汬湩景猠楯ɺ倁爀漀瘀椀搀椀渀最 愀渀搀 愀瀀瀀氀礀椀渀最 眀愀琀攀爀瀀爀漀漀昀椀渀最 ☀ 䠀攀愀琀 爀攀昀氀攀挀琀椀渀最 爀漀漀昀 挀漀愀琀椀渀最 眀椀琀栀 ─ 愀挀爀礀氀椀挀 攀氀愀猀琀漀洀攀爀椀挀 瀀漀氀礀洀攀爀猀⸀ 䌀漀渀琀愀椀渀猀 ㌀ ─ 嘀漀氀甀洀攀 猀漀氀椀搀Ⰰ 琀攀渀猀椀氀攀 猀琀爀攀渀最琀栀 㠀 欀最⼀挀洀눀Ⰰ 挀爀愀挀欀 戀爀椀搀最椀渀最Ⰰ 嘀伀䌀 ㌀ 넀 㔀 最洀⼀氀琀爀 甀瀀琀漀 ㈀ 洀洀⸀ 琀栀攀渀 愀瀀瀀氀礀椀渀最 琀眀漀 挀漀愀琀猀 眀椀琀栀 昀漀爀挀攀搀 挀漀瘀攀爀愀最攀 漀昀 ㈀ 猀焀昀琀⼀氀琀爀⼀琀眀漀 挀漀愀琀猀⸀ 吀栀攀 漀瀀攀爀愀琀椀漀渀 猀栀愀氀氀 戀攀 挀愀爀爀椀攀搀 漀甀琀 愀昀琀攀爀 猀挀爀愀瀀瀀椀渀最 ☀ 瀀爀漀瀀攀氀礀 挀氀攀渀椀渀最 琀栀攀 猀甀爀昀愀挀攀 琀漀 爀攀洀漀瘀攀 氀漀漀猀攀 瀀愀爀琀椀挀氀攀猀 眀椀琀栀 眀椀爀攀 戀爀甀猀栀⼀䨀攀琀 眀愀猀栀攀爀⸀ 䄀瀀瀀氀礀 挀漀愀琀 䀀 氀琀爀⼀ 猀焀洀 ☀ ㌀ 甀渀搀椀氀甀琀攀搀 挀漀愀琀猀 䀀 㠀 氀琀爀⼀ 猀焀洀 眀椀琀栀 㐀 栀爀猀 椀渀琀攀爀瘀愀氀 漀昀 攀愀挀栀 挀漀愀琀⸀吀栀攀 眀漀爀欀 猀栀愀氀氀 戀攀 挀愀爀爀椀攀搀 漀甀琀 愀猀 爀攀挀漀洀洀攀渀搀攀搀 戀礀 琀栀攀 洀愀渀甀昀愀挀琀甀爀攀爀ᤀ猠 猀瀀攀挀椀昀椀挀愀琀椀漀渀 ☀ 琀栀攀 搀椀爀攀挀琀椀漀渀 漀昀 琀栀攀 䔀渀最椀渀攀攀爀ⴀ 椀渀ⴀ䌀栀愀爀最攀⸀᠀ĂProviding & applying single pack component, solvent-free, cold applied, Polyurethane modified, elastomeric liquid applied waterproofing membrane- PU coat with excellent UV resistant capacity, The material shall meet the requirement as specified in ASTM D2370-98 of elongation at break of film>350% with geotextile fleece =50% approx.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. The product performance shall carry guaranteed for 5 year against any leakage.Ĉ䘀牯䠠牯穩湯慴畳晲捡眨瑩敇瑯硥楴敬映敬捥⥥琠潷挠慯獴眠瑩潨瑵搠汩瑵潩…‱敓晬瀠楲業杮挠慯㔠┰搠汩瑵潩楷桴眠瑡牥䀠ㄠ‰杫洯茲䐀蜀潆潈楲潺瑮污猠牵慦散⠠楷桴畯⁴敇瑯硥楴敬映敬捥⥥琠潷挠慯獴眠瑩潨瑵搠汩瑵潩…‱敓晬瀠楲業杮挠慯㔠┰搠汩瑵潩楷桴眠瑡牥䀠ㄠ‰杫洯牐癯摩湩湡業楸杮椠瑮来慲牣獹慴汬湩摡業瑸牵潦慷整牰潯楦杮琠敲瑡敭瑮琠䍒⁃瑳畲瑣牵獥氠歩慢敳敭瑮爠晡ⱴ爠瑥楡楮杮眠污獬敲敳癲潩Ⱳ猠睥条…慷整牴慥浴湥⁴汰湡ⱴ琠湵敮獬⼠猠扵慷⁹湡潃灭牡摥眠瑩潣瑮潲潣据敲整愠数䥄⁎〱㠴愠摮爠獥獩慴瑮琠㘱戠牡栠摹潲瑳瑡捩瀠敲獳牵吠敨挠祲瑳污楬敮愠浤硩畴敲猠慨汬戠慣慰汢景猠汥ⵦ敨污湩景挠慲正灵琠楷瑤景〠㔮洰吠敨眠牯桳污敢挠牡楲摥漠瑵愠汬挠浯汰瑥獡瀠牥猠数楣楦慣楴湯愠摮琠敨搠物捥楴湯漠桴湅楧敮牥椭桃牡敧倮吠敨瀠潲畤瑣瀠牥潦浲湡散猠慨汬挠牡祲朠慵慲瑮敥映牯ㄠ‰敹牡条楡獮⁴湡⁹敬歡条̡倀潲楶楤杮愠摮愠灰祬湩湩整牧污挠祲瑳污楬敮猠畬牲⁹景栠摹潲桰汩捩椠慮畴敲映牯眠瑡牥牰潯楦杮琠敲瑡敭瑮琠桴䍒⁃瑳畲瑣牵獥氠歩敲慴湩湩慷汬景琠敨戠獡浥湥ⱴ眠瑡牥琠湡獫潲景猠慬獢潰楤浵ⱳ爠獥牥楶牯敳慷敧☠眠瑡牥琠敲瑡敭瑮瀠慬瑮畴湮汥 畳睢祡愠摮戠楲杤敤正攠捴桔慭整楲污猠慨汬洠敥⁴桴敲畱物浥湥獴愠灳捥晩敩湩䄠䥃ㄲⴲ刳㈭‰祢爠摥捵湩数浲慥楢楬祴漠潣据敲整戠⁹潭敲琠慨〹‥潣灭牡摥眠瑩潣瑮潲潣据敲整愠数䥄⁎〱㠴愠摮爠獥獩慴瑮琠㘱戠牡栠摹潲瑳瑡捩瀠敲獳牵湯瀠獯瑩癩楳敤桔牣獹慴汬湩汳牵祲猠慨汬戠慣慰汢景猠汥ⵦ栠慥楬杮漠牣捡獫甠⁰潴愠眠摩桴漠⸰〵浭桔潷歲猠慨汬戠慣牲敩畯⁴污潣灭敬整愠数灳捥晩捩瑡潩湡桴楤敲瑣潩景琠 sqm 16886
e engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.22.33.122.33.2&Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product Performance shall carry guarantee for 10 years against any leakage.For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat.ËProviding and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.dProviding and applying waterproofing treatment in bathroom or tiled balcony area without breaking or removing tiles, by using waterproofing sheets as per manufacturer's data sheet instructions. Permitting use of bathroom/balcony after 24 hours of application of treatement, Complete with materials and labour and gurantee of leakage for a period of 5 year.bProviding and fixing 2 mm thick homogeneous conductive PVC (Poly Vinyl Flooring) EN (European Standard), total weight is 3250 g/m2, approx. PUR (Polyurethane Reinforced ), abrasion group P: d"2.00 mm, residual indentation approx. 0.03 mm, anti-bacterial and fungal resistance, castor wheel test qualified, dimensional Phthalate free, directional in design.The floor finish should be termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto 100mm.Recommended to use in area like ICU , Post operative, Recovery rooms, OPD, Patient rooms, Corridors ,passages etc.Providing and fixing permanently static dissipative pressed homogeneous conductive PVC ( Poly Vinyl Flooring) EN (European Standard), anti static, wear layer thickness is 2mm (EN429), vinyl flooring having carbon backing with total weight 3000 g/m2 ESD approved, restorable properties, available in rolls. 100% recyclable (eco - freindly). Low VOC emission after 28days of installation (lower than d"100¼g/m3), Phthalate free non-directional in Design. Recommended to use in area like Operation theater, ICU, Server room, etc.ZProviding and fixing 0.92mm thick hetrogeneous compact PVC (Poly Vinyl Wall Covering) for Interior wall area, with wear layer thickness 0.12mm of PVC, EN(European Standard) total weight is 1500 g/m2, approx PUR (Polyurethane Reinforced), good resistance to chemical and fire, doesn t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28 days of installation (lower than d"10¼g/m3), phthalate free, directional in design, The wall finish should termite free at the room perimeter. Recommended to use in area like OT,ICU, Corridors, Patient Room etc.?Providing and fixing 1.3mm thick homogeneous PVC (Poly Vinyl Wall Covering) for interior area with wear layer thickness 1.3 mm of PVC, EN (European Standard) total weight is 2100 g/m2,approx. PUR (Polyurethane Reinforced), good resistant to chemical and fire, doesn t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28days of installation (lower than d"10¼g/m3), phthalate free, directional in design.The wall finish should termite free at the room. Recommended to use in area like OT.ICU,Corridors, Passages , Patient Room EtcSupply and installation of 2mm thick homogeneous vinyl flooring, Highest abrasion wear rating Group T (EN660), binder content exceeds 55% of the flooring composition, no waste technology, consisting of PVC resin, plasticizers and stabilizers, type I. flooring ( (EN ISO 23997) max 0.4%, Abrasion group (MSZ EN 660-1) T, Fire resistance EN 13501-1 BF1-s1, Slip resistance DIN 51130 R9, EN 13893 DS, electrical resistance EN 1815 <2 kv, Chemical resistance EN ISO 26987, Castor chair resistance EN ISO 4918, Hygenie Bacterial resistant, Seaming method - hot welding, finishing complete . Recommended to use in area like Operation theater, ICU, Server room, etc.² Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ- 150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800- 1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO- V8i/A
436 9.225 rchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.The main frame shall be fixed to RCC slab or Plinth Tie beam, over Neoprene rubber using self- expanding carbon steel anchor bolt of dia. as per design subject to minimum 12 mm diametre and minimum 121 mm length, confirming to AISI 304 and 316 at 500 mm c/c with minimum embedment of 100 mm in RCC (RCC to be paid separately) and located not more than 300 mm from corners or termination of bottom tracks complete in all respects.Welding shall not be permitted to the member of structure having thickness less than 1.09 mm. Load- bearing steel framing members shall have a legible label, stamp, stencil or embossment, spaced at a minimum of 1200 mm on center along the length of the member, with the following minimum information: Manufacturer's Name; Minimum uncoated steel thickness in mm, Minimum coating designation and, Minimum yieldstrength in MPa.Rate is inclusive of designing charges contractor shall submit shop drawings and structural stability report from any structural engineer empanelled in o/o the chief architect, MPPWD or NIT/IIT.@Design, supply, fabrication, Transport and erection of structural Steel/Mild Steel built-up sections for Pre- Engineered steel building in column, Rafter, Truss, floor joist, Wind Bracings, Tie Beam, foundation bolts, Fasteners etc. including two coats of Epoxy paint and one coat of prime. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line, Welding shall be in full depth on both sides of the plate adopting relevant I.S. Code, design of PEB Steel building to be proof checked by any NIT/IITProviding and fixing Trim for window and door 1mm thick with zinc coating not less than 275gm/m3 galvanizedsheet material Girth up to 400mm._@`=JProviding and Fixing neoprene rubber in between wall frame and foundation.ÌProviding and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000, category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approvedmake. A grove of 2 mm to 3mm shall be maintained and groves shall besealed with silicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25to 45 mm and internal face 12.5mm thick gypsum plaster board fixed on 8mm thick fiber cement boardconfirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixedwith self-drilling / taping screws /fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. Including breathable vapour barrier underneath the cement fiber board as per national building code 2009 complete as per direction of Engineer-in-Charge. (costof frame work to be paid for separately).cNote: Insulating material is not required in the hollow wall space between two cement fiber boards.=ïProviding and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8mm thick fiber cement board conforming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately) Note: Insulating material is not required in the hollow wall space between two cement fiber boards.=¿Providing and fixing in all exterior face panels breathable vapor barrier underneath the cement fiber board asper National Building Code 2009 complete as per direction of Engineer- in-charge.kSupplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS14862:2000 of category III type B as per standard sizes fixed with self-drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.BProviding and fixing thermal insulation with Resin Bonded glass wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by crisscrossing GI wire etc. complete as per directions of Engineer-in-Charge.s@t=24.9.1<Providing and fixing insulation with resin bonded Glass wool24.9.2;Providing and fixing insulation with resin bonded Rock woolSupply and installation of moisture/fire resistant lap siding 8 mm thick and width as per standard sizes made of cement fiber board with embossed decorative finish to give pleasing exterior finish fixed horizontally withstaggered joints including minimum overlap of 32 mm on external cement fiber board conforming to IS 14862:2000 fixed with self- drilling/tapping screws/fasteners of approved make.Providing and fixing precoatedgalvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm + 0.05 %, total coated thicknesswith zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.9Providing and fixing precoatedgalvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping sqm 1429
437 9.226 screws complete :24.12.124.12.224.12.324.12.4Barge board (Upto 300 mm).24.12.524.12.6 Gutter. (600 mm over all girth).}Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fiber glass wool conforming to IS: 8183 density 24kg/m3, 50mm thick, wrapped in aluminium foil laminated placed over metal mesh between the gape of purlin and sheet with wire mesh of 12.5mm x24 gauge wire mesh, using self- drilling/ self-taping screws of size (5.5x55mm), EPDM seal.@=24.13.1<Providing and fixing under deck fiber glass wool insulation.24.13.25Providing and fixing under deck rock wool insulation.tProviding and fixing PUF insulated continuous sandwich panels for roofs of total thickness not less than 30 mm made out from continue line method panel shall have pre coated GI sheet on both side of Polyurethane foam with external face being corrugated in shape for GI and PU foam both material. The crest height of the panel shall be of 35 mm minimum with 250mm c/c pitch. The Precoated sheet shall be ofminimum 240mpa steel grade confirming to IS 14245:1995 and shall have zinc coating of 120 gsm as perIS:277, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches whiletransportation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90 mm self-drilling bolts with rubber washer including all types of flashings. PU Foam must be self-extinguishing. Fire retardant type having minimum density of 40 Kg/ Cum.(±2 Kgs) including 0.25 mm craft paper edging, self-tapping screws of required length and nos. etc. complete as per structural design and direction of Engineer-in- charge.24.14.1*PPGI sheet 0.5mm thick skin on both sides.24.14.2+PPGI sheet 0.35mm thick skin on both sides.±Providing and fixing PUF insulated continuous sandwich panels for wall of total thickness not less than 50 mm or 40mm (as specified) and width 1.0m, made out from continue line method on automatic plant. Panel shall have pre coated GI sheet on both side of Polyurethane foam confirming to IS 12436:1988. The precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 micron. ThePPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The panels shall be vertically joined together by tongue and groove joints. The PU foam shall be self- extinguishing, fire retardant type havingminimum density of 40 kg/Cum. (±2 Kgs) including 0.25 mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick craft paper edging on both edges. The panels shall be fixed to the steel frame structure with minimum 5mm thick self- tapping GI screws of required length and nos. with minimum spacing of 300 mm c/c. UUF panel 40 mm thick.24.15.1 24.15.1.1 24.15.1.224.15.2PUF panels for 40 mm thick wall 24.15.2.1 24.15.2.2ÿSupply and installation of moisture/fire resistant solid wall 75mm thick non asbestos fiber reinforced aerated cement sandwich panel made out of light weight fiber reinforced aerated cement/ concrete core composed of Portland cement, fly ash, binders etc. and 4mm thick non asbestos fiber cement board conforming to IS 14862:2000 and ISO : 8336:1993 (E) on either side of the core, having a tongue and groove on longitudinal side of the panels and fixed to steel structure frame by pre- coated water head self-drilling/tapping fasteners of minimum 100 mm length and 4 mm dia of approved make as per design. Rate include for supply and fixing of 15mm high density non asbestos fiber cement board conforming to IS 14862:2000 and ISO 8336:1993 (E) on exterior side of the steel structure frame with similar fastening arrangement. The joints of the cement boards must be sealed with polymer fortified thin set mortar and self- adhesive alkali resistant dry wall fiber mesh tape of minimum 100 mm width complete in all respects.åProviding and fixing of Bottom and top U track for closing of end joints for cut PUF panels. The U track shall be made out of 1 mm thick pre coated GI sheet. The Precoated sheet shall be ofminimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS:277: 1992 , 5-7 microns epoxyprimer on both side of the sheet andpolyester top coat 15-18 micron. ThePPGI Sheet shall have plastic protectiveguard film of minimum 25 microns to avoid scratches during transportation. The U track shall be fixed with suitable POP rivet with wall roof panels and plinth with Expandable fasteners withminimum spacing of 450 mm c/c. The Utrack shall be fixed to RCC Plinth or Tie Beams by suitable anchor bolts.24.17.1>For panel of size of 52mmx30mm with 5mm lipping on both edges.24.17.2>For panel of size of 42mmx30mm with 5mm lipping on both edges.ðSupplying and installation of magnesia block 66 mm thick drywall partition including Framework includes Floor/ Head GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed tofloor and ceiling with suitable fasteners at 300mm centers staggered. Noise and fire rated silicon bead sealant to be caulked along the perimetre of thepartition frame before fixing channels. Then Stud channel having thickness 0.45mm, length 3600mm, unequal flanges of 34/36mm and web of 48mm should be placed into the floor/head channel positioned vertically at 600mm centers. Extra reinforcement to be provided at openings (doors, windows, etc.,)The first layer of magnesia oxide block 8mm thick should be fixed on oneside of the Stud framework in a staggered pattern by using suitable metal fasteners at 3 sqm 26456
0mm centers. Second layer of magnesia oxide block 8mm thick should be fixed other side of the frame work similar fashion as the first layer. 3mm gap should be maintained between boards.3 mm gap shall be filled with jointing compound. Magnesia oxide block shall have following physical characteristics. " Core - Magnesia " Fire Rating upto 150mins " Acoustics STC upto 44-50 " Climate (OC RH) 50, 99 " Moisture Absorption - 6.8% after 2hrs and 11.3% after 24hrs soaking " Wet Expansion - < 0.02% from ambient to saturation " Dry Contraction - d" 0.02% from evaporation " Moisture Movement - 0.02% " Light reflectance 80 % " Green (RC %) 30 " Strength - Antisag " Impact - 4kg hammer 175mm áAdd extra for providin
438 9.227 g and fixing Thermal insulation by providing 50mm thick synth PF (Phenolic Foam) having density 1000 GSM within the cavity held in position by using chicken wire mesh/ cross bracing/ pasting to the wall.!Supply and installation of moisture/fire resistant solid wall 75mm thick non asbestos fiber reinforced with expanded polysteryrene sandwich panel made out of light weight fiber cement facing board composed of Portland cement, fly ash, binders expanded polystyrenebeads etc. and 4mm thick non asbestos fiber cement board (category 3 type B) conforming to IS 14862:2000 and ISO : 8336:1993 (E) on either side of the core, having a tongue and groove on longitudinal side of the panels and fixed to steel structure frame by pre-coated water head self-drilling/tappingfasteners of minimum 100 mm length and 4 mm dia of approved make as per design. Rate include for supply andfixing of 15mm high density non asbestos fiber cement board conforming to IS 14862:2000 and ISO 8336:1993 (E) on exterior side of the steel structure frame with similar fastening arrangement. The joints of the cement boards must be sealed with polymer fortified thin set mortar and self- adhesivealkali resistant dry wall fiber mesh tape of minimum 100 mm width complete in all respects.Supply and installation of termite proof, moisture/fire resistant cement bonded particle board confirming to IS: 14276: 1995 in wall panel on structure to form wall/partition wall on external face of the frame fixed the self-drilling/tapping screws/fasteners of approved make. The hollow wall space between two cement particle board providing with 50mm thick resin bonded glass wool insulation conforming to IS 8183 of density not less than 48kg/cum (glass wool insulation shall be paid separately). All exterior faces of the wall/frame shall essentially be provided with breathable vapor barrier underneath of the cement bonded particle board. The inslattional of the vapor barrier should conforming to the provision of the international building code 2009 and as per the design, The joints of the cement board must be sealed with polymer modified thin set mortar conforming to ANSI A 118.4 standard and self-adhesivealkali resistant dry wall fiber mesh tap of minimum 100 mm width. All exterior wall corner of cement bonded particle board wall panel must be reinforced with galvanized metal angel of 100X100X1.09 mm thickness and fixed on both adjoining walls with self- drilling/tapping fasteners of approved make as per design including providing silicone gel caulking complete in all respects.24.21.1812mm thick cement bonded particle board as per IS: 1427624.21.2810mm thick cement bonded particle board as per IS: 14276$Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core panels made of core material of EPS granule balls/beads (conforming to IS 4671:1984 and shall have density notless than 15kg per cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fiber cement board confirming to IS 14862:2000 or Calcium silicate board confirming to EN 14306:2009 of 5mm thick each. Panel shall be laid on 6mm thick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall be preferably fixed into 'C' channel made of 1.2mm thick MS plate screwed/fastenened to the slab/column/beam etc. The panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor &roofing with additional structural support, steel or RCC depending upon the design. All the operation shall becompleted in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except "C channel" which will be paid separately).24.22.13Non load bearing panels 50mm thick of required size24.22.23Non load bearing panels 60mm thick of required size24.22.33Non load bearing panels 75mm thick of required size24.22.43Non load bearing panels 90mm thick of required size24.22.54Non load bearing panels 100mm thick of required sizeüProviding and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibrecement board confirming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer's and fixed to floor andRCC soffit in plumb to each other with steel screw/fasteners. The panel shall befixed vertically with tongue & groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymerbased jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in- Charge (Cost of all the material is included except "tracks/C channel" which will be paid separately).24.23.1YNon load bearing panels 50mm thick of required size (minimum 4mm thickfibre cement board)24.23.2ZNon load bearing panels 75mm thick of required size (minimum 5mm thickfibre cement board))Providing and fixing white vitreous china Anti germ Fluoro-Polymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- ótrap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required.25.1.1White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 260 x 440 x 580mm With integral foot rests. (Premium Range)25.1.2White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 445 x 585 x 260 mm with integral foot rests. (Premium Range)Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required.25.2.1Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. with solid poly propelyne made soft closing seat cover (Premium Range)25.2.2£Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 350 x 480 x 390 mm with solid poly propelyne made soft closing seat cover (Premium Range)Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required.25.3.1£Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 350 X 360 X 545mm with solid poly propelyne made soft closing seat cover (Premium Range)25.3.2¤Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 570 x 360mm with solid poly propelyne made, soft closing seat cover (Premium Range)25.3.3¤Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 640 x 690mm with solid poly propelyne made, soft closing seat cover (Premium Range)25.3.4´Anti germ Fluoro-Polymer Coated (N sqm 3364
ano coating) Wall hung water closet size 360 x 535 x 380mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range)AProviding and fixing white vitreous china Anti germ fluoro-polymer coated couple water closet flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete .25.4.1Anti germ Fluoro-Polymer Coated couple water closet Size 760 X 360 X 635mm with solid poly propelyne made soft closing seat cover. (Premium Range)25.4.2Anti germ Fluoro-Polymer Coated couple water closet Size 405 x 730 x 800mm with solid poly propelyne made soft closing seat cover. (Premium Range)25.4.3Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range)25.4.4Anti germ Fluoro-Polymer Coated couple water closet Size 375 x 650 x 800mm with solid poly propelyne made soft closing seat cover. (Premium Range)>Providing and fixing white vitreous china Anti germ fluoro-polymer coated single piece W.C. dual flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete.25.5.1Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 770 X 375 X 695mm with solid poly propelyne made soft closing seat coverEach.(Premium Range)25.5.2Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370 x 685 x 835mm with solid poly propelyne made soft closing seat cover.(Premium Range)25.5.3Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 390 x 710 x 710mm with solid poly propelyne made soft closing seat cover.(Premium Range)25.5.4Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 360 x 640 x 690mm with solid poly propelyne made soft closing seat cover.(Premium Range)nProviding and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet along with dual flushing cistern flushing capacity 3 & 6 litre approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete.25.6.1Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 760X360X635mm with solid poly propelyne made soft closing seat cover (Premium Range)25.6.2×Providing and fixing
439 9.228 e vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 365x635x770mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range)ÒProviding and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol technology), 15mm quarter turn angular stop cock, 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required.25.7.1µWhite Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 160x580x450 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range)Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete.25.8.1´White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 1570x415x200mm with wall mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range)25.8.2åProviding and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x820x195mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology). (Premium Range)Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted single lever concealed basin mixture, (cartridge size 32 mm) 32 mm C. P. brass waste coupling length 130mm and 32 mm C. P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range)25.9.1±White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 1615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range)25.9.2ÌProviding and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range)¼Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with 15 mm Table mounted single lever Tall boy basin mixture, (cartridge size 32 mm) 15mm quarter turn angular stop cock, 32 mm C. P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required.25.10.1²White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 1595x435x185mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range)25.10.2©White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range)Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated urinal (Inbuilt spreaders, bottle trap and ceramic waste coupling) with 15mm brass pressmatic auto closing concealed urinal flush valve with wall flange (decol technology, 400000 operation warranted) i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete .25.11.1`White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range)25.11.2dWhite Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 475 x 315 x 715 mm. (Premium Range)25.11.3dWhite Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 385 x 325 x 635 mm. (Premium Range)Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required .25.12.1ÒWhite Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340 X 325 X650 mm with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock. (Premium Range)25.12.2¼White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385 x 325 x 635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range)Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with 15mm Brass made pressmatic (Decol technology, 400000 operation warranted) concealed flushing Stop cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required .25.13.1íWhite Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 840 X 300 X740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range)&Providing and fixing white vitreous china Flat Back sqm 3178
Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensor complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required.25.14.1ÉWhite Vetrious China made Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) Size 340 X 325 X650 mm with sensor (Premium Range)25.14.2ßProviding and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 475x 315 x 715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor for flushing. (Premium Range)Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with chrome plating. (Premium Range)Providing & Fixing 8mm thick froasted Urinal glass partition size height 900 mm top width 450mm and bottom width 300mm brass made bracket $with chrome plating. (Premium Range)Providing & Fixing plain bath tub of size 180x80x47cm body made of PMMA (Poly Methyl metha acrylate) with 20mm wooden reinforcement. (Premium Range)ØProviding and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Pillar cock. (Premium Range)ÔProviding and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range)ÝProviding and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range)ßProviding and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Concealed stop cock. (Premium Range)ÓProviding and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range)ÐProviding and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 3-in1 Wall Mixer .(Premium Range Sanitary Ware)Providing and fixing in position best Indian C. P. brass made quarter turn (Ceramic disc Size 25mm) Flush Cock for Indian W. C. (Orissa Pan). (Premium Range)ÊProviding and fixing in position best Indian single Lever Auto Mixing Wall Mixer (Cartridge Size 40mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range)ÏProviding and fixing in position best Indian single Lever Auto mixing Basin Mixer (Cartridge Size 32mm, nickel plating 0.10 micron and chrome plating 0.3 micron) For Wash Basin area use only. (Premium Range)ÈProviding and fixing in position best Indian single Lever Auto Mixing Diverter (Cartridge Size 47mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range)Providing and fixing in position best Indian C. P. brass made Spout (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range)¡Providing and fixing in position best Indian C. P. brass made Shower Arm Length 300mm (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range)®Providing and fixing in position best Indian C. P. brass made Shower Arm Length 450mm (nickel plating 0.10 micron and chrome plating 0.3 micron).(Premium Range Sanitary Ware)¯Providing and fixing in position best Indian C. P. brass made Shower Arm Length 600mm (nickel plating 0.10 micron and chrome plating 0.3 micron) .(Premium Range Sanitary Ware)´Providing and fixing in position best Indian shower rose 300mm dia body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range Sanitary Ware)§Providing and fixing in position best Indian shower rose 150mm dia, body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range)§Providing and fixing in position best Indian shower rose 200mm dia body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles .(Premium Range)±Providing and fixing in position best Indian shower rose 240mm body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) size 190x295mmÛProviding and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range)±Providing and fixing in position best Indian Health Faucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware)Providing and fixing in position best Indian Auto Closing Pillar Cock (with DECOL cartridge) for wash basin use. (Premium Range)~Providing and fixing in position best Indian Auto Closing Bib Cock (with DECOL cartridge) for common area use. (Premium Range)Providing and fixing in position best Indian Auto Closing Urinal valve open type (with DECOL cartridge) for urinal use only. (Premium Range)Providing and fixing in position best Indian Auto Closing Urinal valve concealed type (with DECOL cartridge) for urinal use only. (Premium Range)Providing and fixing in position best Indian Auto Closing wall mounted Pillar Cock (with DECOL cartridge) for wash basin use only. (Premium Range)µProviding and fixing in position best Indian Auto Closing 40mm Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range)ÏProviding and fixing in position best Indian Auto Closing 40mm Dual Flow (3.0/6.0 liter) Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range)µProviding and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range)oProviding and fixing in position best Indian Sensotronic Sensor Faucet for Wash Basin use only. (Premium Range)kProviding and fixing in position best Indian Sensotronic Sensor Faucet For Urinal use only. (Premium Range)Providing and fixing in position best Indian Sensotronic Sensor concealed type Faucet For Wall Mounted Water Closet use only. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 300 mm long. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Swivel Towel holder Twin Type. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dish Holder. (Premium Range)¢Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dispenser with Metallic Bottle. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Tumbler Holder. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet paper holder with Flap. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range)¨Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Glass Self-size 600mm with toughened glass (Premium Range
440 9.229 )Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Double coat Hook. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Towel Rake 600 mm. (Premium Range)Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) W. C. Brush Holder. (Premium Range)tProviding & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range)°Wall Hung Basin: Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range)25.63.1qwhite Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range)25.63.2qwhite Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range)25.63.3qwhite Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 595x400x365 mm. (Premium Range)25.63.4qwhite Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 500x440x380 mm. (Premium Range)25.63.5qwhite Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 625x485x305 mm. (Premium Range)ªWall Hung Basin ; Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, 15 mm C. P. brass pillar cock, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range)25.64.1qwhite Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 420x480x185 mm. (Premium Range)ÐProviding and fixing in position best Indian, quarter turn table mounted sink mixer (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range)ÎProviding and fixing in position best Indian, quarter turn wall mounted sink cock (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range)Shower Glass Cubical: Providing and fixing toughen glass shower enclosure conformed Is 2553 (part 1. 1990) or IS 14900. 2000 or IS 2835.1987 or IS 14450. 2000 with C. P. brass 5 Year warranted hardware, 19mm dia SS 304 grade stabilizer, all plastic Parts of food grade plastic and all glass shall be toughened at 700 degree Celsius and Anti lime scale treated including painting of fittings, cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range)25.67.1{Providing and fixing 8 mm toughen glass wall to wall sliding shower enclosure size 1200mm X 12000mmX1950mm. (Premium Range)25.67.2£Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts size 2000mm x 1500mm x2000mm. (Premium Range)25.67.3ÖProviding and fixing corner entry 6 mm toughen glass made to measurement shower enclosure size 2000mm x800mm x 200mm with aluminum profile on sides, shower enclosure with door sliding on both sides. (Premium Range)^Shower Panel : Providing and fixing shower panel with Anti finger point stainless steel body finish, Inbuilt absolute butadiene styrene (ABS) top shower with 60 nozzles and waterfall, embedded self, brass spout, multifunction water diverter for top shower, waterfall, hand shower, body jets, brass faucet body with thermostatic mixer. (Premium Range)âShower Panel : Providing and fixing shower panel of stainless steel structure, 200mm square overhead shower , 3 adjustable vertical jets (round), mixer and diverter, hand shower with 1 metre long flexible tube. (Premium Range)3Thermostat Mixer : Providing and fixing in position best Indian, concealed high flow bath and shower mixer with thermostatic control cartridge (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range)gProviding and fixing in position best Indian, exposed wall mounted bath and shower mixer with thermostatic control cartridge with button attachment on spout with connecting legs and wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) .(Premium Range)dProviding and fixing in position best indian, eko exposed shower mixer (wall mounted) with thermostatic control cartridge, 115mm long bend pipe on lower side, connecting legs and wall flange (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range)MProviding and fixing in position best Indian, exposed shower mixer (tub mounted) with thermostatic control cartridge, with button attachment on spout with straight legs (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range)}Providing and fixing in position best Indian, 4 - way diverter consisting of concealed body and wall flange for multiple shower working with one shut-off position and 3 outlets for body shower, head shower and spout ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range)Providing and fixing in position best Indian, thermostatic concealed high flow control valve with wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range)]Medical Faucets: Providing and fixing in position best indian, single lever surgical purpose elbow action basin mounted mixer with extended Operating lever without popup waste system with 450mm long braided hoses (cartage size32mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3micron, quarterturn).(Premium Range)Providing and fixing in position best Indian, surgical purpose elbow action pillar cock with extended Operating lever.( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) (Premium Range)Providing and fixing in position best Indian, surgical purpose elbow action wall mounted pillar cock with extended Operating lever and wall flange. (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range)ÈProviding and fixing in position best Indian, 692mm long, satin finish C. P. Brass grab bar made of 304 grade ss i/c all nuts and screw (0.3 micron chrome and 10 micron nickel plated). (Premium Range)àProviding and fixing in position best Indian, satin finish, C. P. Brass grab bar with left/right 90 degree angle, made of 304 grade ss i/c all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range)ºProviding and fixing in position best Indian, C. P. Brass grab bar vertical swing, 304 grade ss made all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range)Providing and fixing 8mm thick frosted safety glass Urinal partition size 900mm height and 450mm width, fixed with C P brass bracket of appropriate size i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete.(Premium Range)þProviding and fixing Stainless steel plate 304 grade of 1.50mm thick, including writing with Embossing of letters of required size including fixing at Sqm 5505
441 9.23 required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge..Providing and fixing of name plate for offices name of Stainless steel plate 304 grade of 1.50mm thick, including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge.YProviding and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with 1.25m Chromium plated Steel Pipe 15mm dia, compete as per direction of Engineer-in-Charge.PProviding and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer-in-Charge.¸Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes welding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-in-Charge.OProviding and fixing of prestressed vertically casted concrete panels (both surfaces should be smooth and having grooves on both faces) of M-40 grade of concrete of size 2100x300x50 mm having minimum 4 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed horizontally in full length of panel with prestressed precast concrete column of M-40 grade of size 3000x150x150 mm having minimum 7 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed vertically in full length to erect precast boundary wall panels to height 2100 mm from GL including excavation of pit of size 750x750x900 mm in all kind of soil except rock for erection of columns and grouting the pit with M-20 grade of concrete. Manufacturing, transportation and installation at site all complete as per the direction of Engineer-in-Charge.CExtra for every additional height of 0.3 m up to height of wall 3 m°Supplying and stacking of good earth specific useful for plantation at site including royalty if any and carriage (earth measured in stacks will be reduced by 20% for payment).Supplying and stacking sludge at site including royalty and carriage (sludge measured in stacks will be reduced by 8% for payment).Supplying and stacking at site dump manure from approved source, including carriage (manure measured in stacks will be reduced by 8% for payment) :ºSpreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).mMixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.ÀDigging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :28.14.1!Holes 120 cm dia and 120 cm deep.28.14.2Holes 60 cm dia and 60 cm deep.28.14.3Holes 45 cm dia and 45 cm deep.28.14.4Holes 30 cm dia and 30 cm deep.ºFilling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and levelling (cost of supplying earth and sludge or manure and mixing excluded).Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm.hProviding and fixing of stone planter (bench) made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1200mm, width 500mm, legs height 500 mm.]Providing and fixing of stone table made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1000mm, width 600mm, legs height 750 mm.®Providing and laying C.C. pavement of mix M- 25 with ready mixed concrete from batching plant including centering and shuttering complete. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, with wire brush etc. complete as per specifications and directions of Engineer- in-Charge.Note: Cement content considered in this item is @ 330 kg/cum.NPreparation of site plan and location plan with total station surveying showing all individual structures and features like trees, roads, culverts, nallas, electric poles, telephone poles, sewer lines, chambers, water supply lines, hand pumps, well etc. complete along with showing location of roads proposed in master plan. i/c Contours of entire area at 0.5 m. intervals using auto level, preparing of site plan in soft copy (using autocad) in suitable scale as desired by engineer-in-charge duly indicating north direction. Rate includes providing 1 digital copy and six hard copies, one print on tracing film, khasra map duly showing the land and location plan (index plan) and google image of the land. Rates are inclusive of transportation charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.)29. 1.1Upto 1 Hectare29.1.21 Hectare to 2 Hectare29.1.3;Add extra for each additional one Hectare or part there off29.1.4/Excavation of trial pit of size 1.20 m X 1.20 m with minimum depth of 0.9 m and maximum depth of 3.5m as directed by the Engineer in Charge. Trial pit shall be taken at suitable location/ locations as directed by Engineer in charge and shall be indicated on the site plan showing details of soil strata.ÑPreparation of double line plan after measurement of internal as well as external dimensions of existing buildings/structures and plotting the same in suitable scale as directed by Engineer-in-charge.+Preparing of double line plan for planning of addition and alteration work after measurement of internal as well as external dimensions and details of existing door window, ventilator openings and partitions, addition /alteration done previously in buildings/structures and plotting the same separately showing sectional elevations (minimum two numbers) and all elevations along with all relevant details like doors, windows stairs etc in suitable scale as directed by Engineer-in-charge. The consultant shall also submit detailed condition survey report.ÛPerforming Plate Load Test (P.L.T.) for Determining soil bearing capacity (SBC) at site including submission of Geotechnical Report and recommending bearing capacity in accordance with IS-1888-1982 (Without Conveyance).per pitíPerforming Standard Penetration Test for determining soil bearing capacity (SBC) in accordance with IS-2131-1981 and submission of Geotechnical Report on bearing capacity based on SPT in accordance with IS-6403-1981 (Without Conveyance)per boreTransportation charges for transportation of Geotechnical testing equipments for plate load te Sqm 5773
442 9.235 st or standard penetration test upto a distance of 100km. (upto 100km going and 100km returning from district H.Q. both way) Rates are inclusive of Loading and unloading of testing equipments and other incidental charges during both journeys to be paid Sqm 7222
443 9.236 tion P.W.D. City Sub Division 03 P.W.D. Maint. Division No.01 ± Bhopal Bhopal BhopalName of Work: AR SR works of sewer line chambers drain etc in Resi. buildings GST department work at all Section of PWD. City Sub Dn. No.3 Bhopal. Contract No: 2025_PWDRB_466683 AR SR works of sewer line chambers drain etc in Resi. buildings GST department work at all Section of PWD. City Sub Dn. No.3 Bhopal. Sqm 5785
463 9.258 nimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.ÌReplacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size):19.19.119.19.2<Supplying and fixing C.I. cover without frame for manholes :19.20.1a455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.19.20.2[500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg.19.20.3\560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg.nProviding and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality19.21.1Light duty D- 2.5 19.21.1.1/Rectangular shape 600x450mm internal dimensions 19.21.1.2&Square shape 450mm internal dimensions 19.21.1.3&Circular shape 450mm internal diameter19.21.2Medium duty - 10 19.21.2.1%Square shape 450mm internal dimension 19.21.2.2&Circular shape 500mm internal diameter19.21.3Heavy duty D - 20 19.21.3.1'Circular shape 560 mm internal diameter19.21.4Extra Heavy Duty - 35 19.21.4.1#Circular shape 560 mm internal dia.Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg.Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :19.23.1 For pipes 100 to 230 mm diameter19.23.2 For pipes 250 to 300 mm diameter19.23.3 For pipes 350 to 450 mm diameteréProviding sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with cement mortar 1:1 (1 cement : 1 sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications :19.24.1*100 mm dia. sand cast iron drop connection19.24.2*150 mm dia. sand cast iron drop connectionJExtra for depths beyond 60 cm of sand cast iron drop connection complete :19.25.1.For 100 mm dia. sand cast iron drop connection19.25.2.For 150 mm dia. sand cast iron drop connectionÃRaising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Brick work for Raising depth of manhole to be paid separately) :19.26.1PRectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.519.26.2MRectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 1019.26.3MRectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 2019.26.4[Circular manhole 140 cm dia with circular cover 600 mm dia of grade Extra heavy duty HD -35ÑConstructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design :19.27.119.27.2(With fly ash bricks 100 key/c
493 10.3 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 153
32 mm long sqm 1231
Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. sqm 578
Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. sqm 642
Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. sqm 709
41000 meter 500
41001 meter 431
41091 meter 459
41092 meter 402
41244 meter 367
41245 meter 311
41246 meter 420
41247 meter 506
12.33.1 Coupler
12.33.2 Single push fit Coupler :
12.33.3 Single tee with door
12.33.4 Single tee without door
12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) each 78
12.33.6 Shoe (Plain)
12.37.1 Stone ware spout each 72
12.37.2 Upvc spout (Pipe dia.110 mm) each 38
41275 1:4 (1 cement : 4 sand) sqm 173
41276 1:6 (1 cement : 6 sand) sqm 160
41306 1:4 (1 cement : 4 sand) sqm 184
41307 1:6 (1 cement : 6 sand) sqm 168
41334 1:4 (1 cement : 4 sand) sqm 245
41335 1:6 (1 cement : 6 sand) sqm 225
41365 1:3 (1 cement : 3 sand) sqm 210
41366 1:4 (1 cement : 4 sand) sqm 203
41395 1:3 (1 cement : 3 sand) sqm 236
41396 1:4 (1 cement : 4 sand) sqm 220
693 13.1 Neat cement punning sqm 30
One coat. sqm 20
Two coats. sqm 32
One coat. sqm 37
Two coats. sqm 56
13.56.1 On steel work sqm 109
13.56.2 On concrete work sqm 113
13.66.1 One coat. sqm 35
13.66.2 Two coats. sqm 53
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete. cum 73829
820 14.38 Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work. sqm 32
831 14.49 Finishing walls with water proofing cement paint of required shade :
14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. sqm 42
14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 30
Providing and fixing 50 mm Stainless steel cup board or wardrobe knob with necessary screws (best make of approved quality) each 122
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : each 74
125x85x5.5 mm (heavy type) each 30
855 14.78 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.
14.78.1 Upto and including 12mm dia metre 78
856 14.79 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
14.79.2 Epoxy bonding adhesive having coverage 2.20 sqm/kg ofapproved make sqm 318
14.83.1 Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work kg 65
14.83.2 Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. kg 68
14.83.3 Epoxy injection grout in concrete/RCC work of approved make kg 658
891 15.3 metre 5
902 15.41 metre
909 15.48 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. sqm 13
(mailto:[email protected]塹ᴻ䡿ⲯ嶂藄挧ꮥ) each 4590
Single tee with door
Single tee without door
9.58.4 meter 429
9.81.3 meter 275
18.6.1 Internal work - Exposed on wall
18.6.1.2 20 mm nominal outer dia .Pipes. metre 153
18.6.1.3 25 mm nominal outer dia .Pipes. metre 177
18.6.1.6 50 mm nominal outer dia .Pipes. metre 528
18.6.2.1 15 mm nominal outer dia .Pipes. metre 207
18.6.2.2 20 mm nominal outer dia .Pipes. metre 234
18.7.1 metre 122
18.7.2 20 mm nominal outer dia .Pipes. metre 141
18.7.3 metre 185
18.7.4 32 mm nominal outer dia .Pipes. metre 238
18.7.5 metre 324
18.7.6 50 mm nominal outer dia .Pipes. metre 498
18.8.1 Internal work - Exposed on wall
18.8.1.1 15 mm dia. nominal bore metre 211
18.8.1.2 20 mm dia. nominal bore metre 255
18.8.1.3 25 mm dia. nominal bore metre 300
18.8.1.4 32 mm dia. nominal bore metre 361
18.8.2.1 15 mm dia nominal bore metre 269
18.8.2.2 20 mm dia nominal bore metre 309
18.8.3 External work : including trenching and refilling etc.
18.8.3.1 15 mm dia. nominal bore metre 188
18.8.3.2 20 mm dia. nominal bore metre 223
18.8.3.3 25 mm dia. nominal bore metre 263
18.8.3.4 32 mm dia. nominal bore metre 310
Internal work - Exposed on wall
25 mm nominal bore each 486
25 mm nominal bore each 341
1031 18.13 Providing and fixing CPVC gate valve with knob of approved quality.
18.13.1 25 mm nominal bore each 428
1032 18.14 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
18.14.1 15 mm nominal bore each 316
18.14.2 20 mm nominal bore each 431
25 mm nominal bore each 499
25 mm nominal bore
32 mm nominal bore
15 mm nominal bore each 236
20 mm nominal bore each 285
25 mm nominal bore each 391
15 mm nominal bore each 88
20 mm nominal bore each 129
15 mm nominal bore each 149
20 mm nominal bore each 184
15 mm nominal bore each 117
20 mm nominal bore each 148
25 mm nominal bore each 158
32 mm nominal bore each 204
1046 18.28 per litre 7
15 mm nominal bore each 306
20 mm nominal bore each 338
15 mm nominal bore each 318
20 mm nominal bore each 344
1071 18.53 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
1078 18.6 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
18.60.1 25 to 40 mm nominal bore each 247
18.60.2 50 to 80 mm nominal bore each 644
1176 22.13 Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. sqm 23
22.14.2 Cement mortar 1:3 (1 cement : 3 sand) cum 9308
22.14.3 Cement mortar 1:4 (1cement : 4 sand) cum 8437
1184 22.21 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. [for item No. 22.18 to 22.20] sqm 59
1185 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of sqm 465
1186 22.23 Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. sqm 544
1193 22.3 Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer-in-Charge metre 55
For vertical surface two coats @ 0.70 kg per sqm sqm 412
For horizontal surface one coat @1.10 kg per sqm. sqm 319
1198 22.35 Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge.The product performance shall carry guarantee for 10 years against any leakage.
22.35.2 For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @ 0.070 kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar @ 0.040 kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040 kg to fill the hole) each hole 16
Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete.
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: Executive Engineer P.W.D. Maint. Dn. No.1 Bhopal
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 BI01010001010000000000000515BI0100001113 1 Nos 2500000 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tenderdocument.pdf
Tender Documents • 7.94 MB
BOQ_548800.xls
BOQ • 1.26 MB
Download all tender documents and submit your bid