Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.7 L+₹85,850.74 (5.79%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹15.8 L+₹1.0 L (6.78%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
₹13.9 L
EMD Value
₹27,800
Closing Date
18 Mar 2020, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
PROVN OF TOILET BLOCK IN TRG AREA OF 1 TRG BN, 1 EME CENTRE UNDER GE(N) SECUNDERABAD
2020_MES_319284_1
CWE(S)/NORTH/TOKEN-31 OF 2019-2020
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE(NORTH) SECUNDERABAD
₹27,800
Yes
11 May 2020
28 Jan 2020
21 Mar 2020
28 Jan 2020
18 Mar 2020
12 Feb 2020
Amount
Surface dressing n exc 15 cm deep and getting out as in hard/ dence soil complete all as specified and directed.
Surface excavation in Hard/Dense soil n exc 30 cm deep averaging 15 cm thick as in hard dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for foundations laying cable, poles etc.or for shafts, manholes etc., and getting out in hard/dense soil complete all as specified and as directed
M&L for PCC 1:4:8, type D2( using 40mm size graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L Brickwork with sub-class 'B' bricks, old size bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L Brickwork with sub-class 'B' bricks, old size bricks straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L Half Brickwork with sub-class 'B' bricks, old size bricks straight or curved on plan exceeding 6m mean radius built in CM 1:4 as in partition wals, complete all as specified and directed.
M&L Rendering 10 mm thick on other than fair faces of brick surfaces built in CM 1:6, finished even and smooth without using extra cement complete all as specified and as directed.
M&L Rendering 5mm thick in CM 1:4 with WPC @ 2% by weight of cement over 10 mm thick in CM 1:6 on other than fair faces of brick surfaces built in cm (1:6), finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 10 mm thick finished fair and smooth without using extra cement in CM 1:4, in ceiling surfaces complete all as specified and as directed.
M & L for preparing plastered surface and applying three coats of white wash on wall complete all as specified and directed.
M & L for preparing plastered surface and applying three coats of white wash on ceiling surfaces complete all as specified and directed.
M & L for preparing plastered surface and applying two coats of cement base paint over a coat of white wash on wall surfaces complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in each layers not exceeding 25cm thick all as specified and as directed.
Removal of excavated surplus soil to a distance not exc 50m away and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Removing excavated material n exc. 250M but n.exc 500M and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M & L Spreading and levelling in layers not exceeding 25cm thick well ramming including watering as required all as specified and as directed.
M & L Plain Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate ), 75mm thick as in sub base all as specified and as directed.
M & L for non skid ceramic coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exc 0.06 Sqm and not exceeding 0.11 Sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for glazed ceramic tiles of 1st quality and size of 300 X 200 X 7 mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile and including laying over 10 mm thick back coat/plastering in CM 1:4 complete all as specified and as directed.
M&L hardcore of broken stones or boulders of guage n exc 63mm,deposited,spread,levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L Rendering 15 mm in cement mortar 1:4, on fair faces of brick work and finished fair and even smooth with using extra cement and mix with 2% water proofing compound by weight of cement complete all as speciified and directed. Note : WPC shall be measured and paid saparately
S&F vitreous china squatting pan Orissa pattern size 580x440mm white integral foot rest including all fittings (excluding flushing cistern and flush pipe) including concrete bedding, P trap, complete all as specified and as directed.
S & F 10 litres capacity PVC low level flushing cistern including brackets complete all as specified and as directed.
S & F Concealed GI tubing of size 15 mm dia, medium grade, laid in floors/ walls complete all as specified and as directed.
S & F GI tubing of size 20 mm dia, medium grade, laid in floors/ walls complete all as directed and as specified
S&F bib taps 15 dia bore, cast copper alloy with crutch or butterfly handle, screwed down, fancy type screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F fancy type stop valves 15 mm dia bore, cast copper alloy, screwed down, high pressure, with crutch or butterly handle, screwed both ends for iron pipe or for unions all as specified and as directed.
S&F Fancy type stop valves 20 mm dia bore, cast copper alloy, screwed down, high pressure, with crutch or butterly handle, screwed both ends for iron pipe or for unions all as specified and as directed.
S&F Pillar taps of 15 dia bore, cast copper alloy with crutch or butterfly handle, screwed down, fancy type screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm all as specified and as directed.
S & F Salt glazed stoneware gully traps, square or round mounted type 'P' of size 150 x 150 mm complete all as specified and as directed.
Supply & fixing PVC (SWR) 75 mm floor trap complete all as specified and as directed..
M&L for PVC ( SWR ) pipes 110 mm dia fixed to walls single socketed with rubber ring joints complete all as specified and directed.
S & F 110 mm bore UPVC (SWR) vent cowl complete all as specified and directed..
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber rings joints, laid in trenches or in floors complete all as specified and as directed..
S&F 75 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
Supply and fixing PVC (SWR) junction single 'T' 110 mm bore equal or unequal with access door complete all as specified and as directed.
Supply and fixing PVC (SWR) bends 75 mm bore, any radius with oval access door complete all as specified and as directed..
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position , complete all as specified and directed.
S& F 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed ( minimum weight 200-210gms) complete all as specified and directed.
S & F Solid PVC door framed of size 50mm x 47 mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube all as specified in SSR Part-II of 2010, complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tube for top & bottom rail, all as per drawing and as specified in SSR Part-II of 2004 complete all as specified and as directed..
M & L for Butt hinges of size 100mm medium weight cold rolled alluminium extruded section and fixed complete all as specified and as directed..
S & F 150 mm long aluminium handles, cast type anodised extruded section and fixed complete all as specified and as directed..
S & F aluminium anodised barrel tower bolt of extruded section of size 150 mm long complete all as specified and as directed.
Supply and fix framed work as in doors or gates of angle or other section with gusset plates, plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering doors,etc., to be prepared for hanging or sliding with and including either covering hooks and hinges or steel hanging door fittings complete all as specified and directed.
M&L for two coates of synthetic enamel paint on steel surfaces over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed
M&L for Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter, for rough finished surface of concrete flat complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, colulnns and stanchions for fair finished surfaces of concrete flat complete all as specified and as directed.
M&L formwork to sides and soffits of suspended slabs such as roof slab, floor slab landings and similar work; not exceeding 200 mm thick (Horizontal or sloping)complete all as specified and as directed.
M & L Reinforced cement concrete M-25 design mix (using 20 mm graded aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L Reinforced cement concrete M-25 design mix (using 20 mm graded aggregate) in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L Reinforced cement concrete M-25 design mix (using 20 mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L Reinforced cement concrete M-25 design mix (using 20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab as in shelves and like complete all as specified and as directed.
M&L for Formwork to sides and soffits of lintel beams, roof beams for fair finished surfaces of concrete complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking, bending, sprillay for hooping for columns, hooking ends and binding with and including MS wire (annealled) not less than 0.90 mm dia complete all as specified and as directed.
M&L for mild steel TMT bars 8mm dia as in stirrups, spacers and binders and over cut to length bend to shape required including cranking, bending, sprillay for hooping for columns, hooking ends and binding with and including MS wire (annealled) not less than 0.90 mm dia complete all as specified and as directed.
M&L Providing precast cement concrete louvres and jallies, 25 mm thick (measured solid) type B-0 1:2:4 (using 12.5 mm graded stone aggregate), including all mouldings but excluding frame complete all as specified and as directed.
M&L for 75 mm thick type PCC 1:3:6 type C2 (using 40mm size graded stone aggregate) as in plinth protection laid in alternate panels including finished the surfaces even and smooth without using extra cement including making 10 mm wide grooves to full depth at junction of wall and plinth protection and at 3 metre intervals and every change of direction and filling the grooves with mixture of bitumen and sand mixed in 1:3 ratio by weight and top 10 mm depth to be sealed with sealing compound grade 'A' complete all as specified and as directed.
S&F for Vitreous China bowl urinal flat back, size of 465x355x265 mm white (minium), with grating and union, out let pipeetc for discharge complete all as specified and as directed. .
S&F Vitreous China urinal partition white of size 310x 700 mm complete all as specified and as directed. .
S&F vitreous china wash basin, white, flat back, size of 550x400mm with brackets, including cutting for pinning in ends of brackets including waste pipe, PTMT 32mm dia, waste coupling 32 mm dia and PVC connection 15 mm dia 300 mm long complete all as directed and specified.
M&L hardcore of broken stones or boulders of guage n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
S&F PTMT waste coupling 32mm bore half or full threaded( minimum weight 32mm - 45 gms) complete all as specified and as directed.
S&F PTMT waste coupling 32mm bore half or full threaded( minimum weight 40mm - 60 gms) complete all as specified and as directed.
S & F PVC waste pipe 32 mm bore for WHB/Urinal complete all as specified and as directed. .
M & L for rendering 10 mm thick in CM 1:4 on fair surfaces of brick work or concrete using water proofing compound . Note: WPC shalll be measured and paid separately.
Supply only water proofing compound.
M&L for preparation of roof surfaces by sweeping with wire brushes to remove projections and cleaning with water from dust and dirt and priming roof surfaces by application of one coat of oil based bitumen emulsion primer @ 0.3 Ltr/Sqm ( or as per the directions of manufacturers instructions) and providing water proofing treatment with APP based polymeric membrane minimum weighing 3.0 Kgs/Sqm and minimum 3mm thickness reinforced with polyester non woven fabric (weight not less than 150 gm / sqm ) as per IS 3384 on primed surface by forced application with 10cm over laps and applying a coat of blown bitumen 85/25 @ 1.2Kg/sqm on top of membrane and finally coating the surface with a coat of bituminious aluminium paint at the rate of 100gm per Sqm complete all as directed and as specified.
M&L for chequerred cement concrete tiles with grey cement and pigments of size 250x250x22mm thick set, jointed and pointed in neat cement slurry in floors over a screed bed of 15mm thick in CM 1:6 complete all as specified and directed.
Extra over forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed..
S & F salt glazed stoneware drain pipe (SGW) grade 'A' laid in trenches and jointed as specified of internal dia of pipe 150mm all as specified and as directed.
M&L for Concrete bed with cement concrete 1:4:8, type D2 using 40mm size graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 150 mm bore complete all as specified and directed.
Provn of on site LLDPE septic tank of conventional type designed to carry sewage and sulage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc ., complete for 30 users capacity complete all as specified and directed.
Provision of soak well exc in ordinary soil, foundation in PCC 1:3:6. well of honey combed and solid in M25 concrete, including intercepting chamber screen chamber brick work in CM, RCC cover slab in M25/RR masonry/filling with brick bats complete of size 1.8m dia x 3.0 m deep complete all as specified and directed.
M & L precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded agg) as in cover slab for man hole set in CM 1:6 complete all specified and directed
Supply, Lay and fixing steel water tubes, medium grade, ISI marked, as per IS-1239 Part I, galvanised with all fittings bends. Tees, elbows, sockets, nipples, tapers, and reducers etc laid in trenches as in repairs complete all as specified and directed for following bore of pipes :-
(a) 50 mm Dia
(b) 25 mm Dia
Supply and Fix gun metal gate valve, ISI marked connected with iron wheel head, screwed at both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for the following sizes.
(a) 50 mm Dia
(b) 25 mm Dia
Supply, Lay, connect, test and commissioning of XLPE insulated (Earthed) screened, PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor, multistranded, 1100 Volts grade, fixed to poles or laid in trenches,floors, ducts, through pipes etc, with suitalbe size cable glands, crimping type lugs for stranded aluminium conductor etc for following size complete all as specified and directed Note : (i) Earth work, cable protection , GI pipe, sand cushioning will be measured and paid separately. (ii) All LT cables to be terminated with heavy type brass glands double compression type and heavy duty CU lugs. The cost of termination is deemed to be included in unit rate quoted.
All as per item No. 80 above here-in-before but for stranded aluminium conductor of size of cross sectional area 4 core 16 sqmm
All as per item No. 80 above here-in-before but for stranded aluminium conductor of size of cross sectional area 3.5 core 25 sqmm
M & L for sand cushioning to under ground cables including punning down of sand in layer complete all as specified and as directed. Note: Thickness of sand cushion after punning down i.e. 18cm shall be measured for payment
Supply and lay un-reinforced precast concrete cable covers, class LV, type-I, flat of size 250mmx150mmx40mm laid across in trenches for cable protection as in repairs complete all as specified and directed.
Supplying, Erecting and fixing in repair Steel tubular swaged poles complete with cast iron base plate of size 300mm x 300mm x 6mm , finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including painting two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and tarring with black bituminous paint to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, including taking down old unserviceable poles of any type complete all as specified and directed. Note : Excavation, Earth work, PCC foundation, coping etc will be measured and paid separately.
M&L for PCC 1:3:6, type C2 ( using 40mm size graded stone aggregate) as in foundations, filling and mass concrete for pole/stay/post including necessary form work complete all as specified and as directed.
M&L for PCC 1:2:4, type B1 using 20mm size graded stone aggregate in coping poles/foundation for poles,struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and as directed.
Supply and lay Galvanised Iron tubing 40 mm bore, light grade in protection of cable at road crossing/hard standing/pole fixed with MS clamps, nut bolts and washer as per site requirement complete all as specified.
Supply and lay Galvanised Iron tubing 50 mm bore, light grade in protection of cable at road crossing/hard standing/pole fixed with MS clamps, nut bolts and washer as per site requirement complete all as specified.
Supply and fix 90 watts LED street light fitings new generation energy saving environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10 KV surge protection road way, luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with 4.0 sq mm multistranded aluminium conductor PVC insulated twin core weather proof cable from fittings to over head lines or to the junction box and fixing to complete all as specified and directed, Make :- Bajaj Cat No BRTFG 90 W LED I or Philips cat No BR 410LED 091 CW HEMR PCS2 PSUGR or equivalent in wipro Notes: (i) LED'S used should be the make of Cree/Osram/Lumilieds/Nitchia, (ii) Contractor has to produce LM-79/ LM-80 certificate along with purchase vouchers. (iii) Surge protection of the drive should be 10 KV or equivalent model in philips or Bajaj.
Earthing complete with galvanised steel earth plate electrode 60cmx 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nuts, checknuts and washers etc., of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of light grade from earth electrode to DBs/main switch all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work in hard dense soil, returning in and removal of surplus soil to a distance not exc 50m, PCC chamber in 1:2:4 Type B-1 using 20mm graded stone aggregate, 40mm thick RCC Cover in 1:2:4 type B-1 reinforced with XPM of weight not less than 4 Kg/Sqm and frame of angle iron 25 x 25 x 6 mm with lugs 2 Nos. and with 6mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling, connection to test point complete all as specified.
Supply and fix storage type Water heater (Geyser) 5 star rating od Cap 25 Ltrs working on 230 volts AC supply with in and out going water connection pipes (cold & hot) and fixing arrangement with nut bolts and making good the disturbed surface all as specified and as directed.
S& F Exhaust fan 300 mm sweep single Heavy duty phase 50 Hz, 1400 RPM AC with provision of making hole on wall with louver and connecting up with and including provision of PVC insulated copper flexible cord of size 23/0,198, 3 core from ceiling rose to connection of exhaust fan on wall complete all as specified and directed.
M & L for point wiring with 1.5 Sqmm FRLS PVC insulated unsheathed single core copper conductor, 1100 Volt grade drawn through and including concealed rigid PVC conduit pipe of suitable dia mediuim grade with all fittings and accessories complete laid/fixed in walls/roofs and 2 mm thick mild steel, duly painted with red oxide metal primer including fixing/grouting sunken/surface as per site requrirement covered with 3mm thick laminated sheet including runing up of 1.5 sqmm copper conductor FRLS PVC insulated cable as earth continuity conductors along with wiring and connecting to common earth dolly all including cutting chases and making good the grooves etc complete as directed by Engineer-in-charge for One light point controlled by one, one way switch 5 Amps, SP all as specified and as directed.
Discription all as item No. 92 , but for or One ceiling fan/exhaust fan point controlled by one, one way switch and regulator all as specified and as directed.
Discription all as item No.92 , but for One 3 pin 5 A switch socket outlet point controlled by one switch on the independent board all as specified and as directed.
Discription all as item No. 92 , but for 3 pin 5 A switch socket outlet point controlled by one switch on the same board all as specified and as directed.
Description all as per item No. 92 here-in-above but using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade for 3 Pin 5 Amps switch socket combination point on independent board including running 2.50 Sqmm copper conductor PVC insulated cable earth continuity conductor all as specified and as directed.
S & F Switch MODULAR 1 WAY 6 amps, 230 volts.
S & F MODULAR socket 2/3 pin 6 amps 2 MODULE 230 volts all as specified.
S & F MODULAR socket 2/3 pin 6/16 amps 2 MODULE 230 volts all as specified.
S & F Switch MODULAR 1 WAY 16 amps, 230 volts.
S & F lamp holder insulated body with back plate for angle/ batten fitting fixed with PVC round blocks complete all as specified and as directed.
S&F ceiling rose surface bakelite 5 amps 230 volt with three terminal 50x65 mm size complete all as specified.
S & F Wall mounted Indus plus LED batten 20W, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver including LED lamp 1 X 20 W, 230 Volts, bipin holders, Diffused type connector block, internally prewired with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make : C & S CAT No. LTIC00120WLED/WD, Havells CAT No.LHFYBYPN1AW022 Incl tube rod CAT No. LHLDDBXEUL7Z020 or BAJAJ CAT No. BLRB21W CWC incl tube rod Cat No. BLRB21W CWC
S & F LED security light fitting of 25 Watt with deep drawn housing including all accessories, lamp and connecting up with and provision of 2.5 Sqmm 3 core 1100 volts grade multistranded copper conductor cable from light fitting to junction box and bracket made out of GI tubing 25mm dia bore not less than 0.6m long bend to required shape for fixing to wall/poles with 2 nos MS clamps made out of MS flat 40 X 5 mm with MS nuts, bolts and washers complete all as specified and as directed. Make : C & S Cat No. LTESSE10X2.5HPLED or Havells CAT No. LHETAXU7PA6S025 or Bajaj CAT No. BCLST25WLED or equivalent as approved
S&F sheet metal enclosure MCB DB SPN 8 Way with 200 Amps rated bus bar 240 Volts double door magnetic locking system complete all as directed and specified.
S&F MCB SPN 230 Volts 'C' Series suitable for fixing in MCB DB's of capacity 40/ 60 Amps complete all as specified and as directed.
S&F MCB SP 240 Volts suitable for fixing in MCB DB's of capacity 5 to 40 Amps complete all as specified and as directed.
M&L modular enclosure cable junction box IP 65, weather proof with hinged door and locking arrangement of size 240mm x 320mm x 135mm internal comprising of one No MCB SP 6 Amps and epoxy porcealin terminal block 6 way suitable for three incoming cable and for outgoing and single phase connection for light fitting with provision of cable entry throgh gland and fixed to the existing/new PCC/Steel pole with suitable clamps made out of MS flat iron 25 x 4mm thick with nuts, bolts and washer complete all as specified and directed. Make :- NEPTUNE Cat Part No 6320 or equivalent model of HENSEL/ABB/Schneider.
Himagiri Constructions
NARAYANA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .