Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-PreQual/Technical 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹58.6 L
EMD Value
₹65,000
Closing Date
19 Oct 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Electricity Construction and Works Division, P.V.V.N.L., Victoria Park, Meerut
Increasing Capacity of various 33 KV SS
2023_PVVNL_840679_2
02/ECWD/MRT/2023-24
Open Tender
Electrical Works
Lump-sum
60 days
Meerut
Please refer tender notice and tender documents
3 documents required · 3 mandatory
₹3,540
Payable to E.E.E.C.W.D., Meerut
₹65,000
7 Dec 2023
13 Oct 2023
19 Oct 2023
13 Oct 2023
19 Oct 2023
13 Oct 2023
Supply of following Items :- 33 KV Line Isolator
33 KV Bus Isolator 800 Amp
33 KV Fuse Set
33 KV Lightening Arrestor
33 KV Post Insulator
24 Volt Battery & Battery charger
PG Clamp for Dog conductor to Panther Conductor
Structure 33 KV Bus Isolator 800 Amp on 125×65×6 mm Galvanised Channel
Structure 33 KV fuse set on 125×65×6 mm Galvanised Channel
Structure 33 KV Lightening Arrestor on 125×65×6 mm Galvanised Channel
Structure 33 KV Post Insulator on 125×65×6 mm Galvanised Channel
Structure 33 KV CT on 125×65×6 mm Galvanised Channel
2×2.5 mm2 Control Cable
4×2.5 mm2 Control Cable
11 KV 3×300mm2 XLPE Cable Jointing Kit (Outdoor)
11 KV 3×300mm2 XLPE Cable Jointing Kit (Indoor)
11 KV 3×185mm2 XLPE Cable Jointing Kit (Outdoor)
11 KV 3×185mm2 XLPE Cable Jointing Kit (Indoor)
Stone Pad (300×300×75mm)
Number Plate with Clamp & Nuts
Danger Board & Clamps with Bolts and nuts
MS Nut & Bolts
M.S. Earthing Rod of 20×2500mm and 6 SWG Wire
Stay Complete (Stay Rod 16×1800mm, Stay Wire 5 Kg, Stay Insulators, Sty Clamps, bolts & nuts with grouting)
Barbed Wire GI
11 KV TPMO with fixing clamp (3 Phase)
11 KV Fuse Set (drop out) with fixing clamp (3 Phase)
Holding Clamp for GI Pipe
Holding Clamp for Channel and Angle
G.I. Channel 100×50×6mm, 2240mm
G.I. Channel 100×50×6mm, 2028mm
G.I Pipe 150 mm Dia, 3 mtr long
Safe carriage of following items from store center (under jurisdiction of PVVNL) to site with loading & unloading at both ends respectively. 11 KV V.C.B. (Outgoing) 200/100/5A, 350 MVA
33 KV VCB 800 Amp, 750 MVA with Steel Structure
11 KV VCB 600/300/5A, 350 MVA I/C
Control panel I/C for 33 KV Double T/F
11 KV Bus Coupler
33 KV C.T 400/200 1A
11 KV 3×300 mm2 XLPE Cable
11 KV 3×185 mm2 XLPE Cable
ACSR Dog Conductor
STP 11 mtr.
11 KV Disc Fitting, Disc Insulator, Pin Insulator (03 No each)
Miscellaneous Civil works of Increasing Capacity of 33/11 KV Substation Plinth for new 5 MVA/10 MVA Transformer (as per specification)
Hiring of D/G Set including carriage, loading, unloading & operating charges (with fuel) at 33/11 KV Substation under construction in case L.T. supply is not available near S/S within prescribed accessible limit. 63 KVA, Three phase, D/G Set for fabrication of different structure at Substation.
Miscellaneous Electrical works of Increasing Capacity of 33/11 KV Substation Installation of 33/11 KV, 05 MVA/10 MVA Transformer : Shifting of available 05 MVA/10 MVA 33/11 KV, Transformer to transformer plinth in Switch Yard.
Erection of shifted Transformer at plinth by fixing all accessories like radiators, conservator tank, filling the transformer oil to desired level and ensuring that there is no leakage, complete job in all respect.
Boring and lowering of G.I. Pipe size 32 mm dia… into the ground up to water level with the lower end of solid copper cone Approx 225mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the M.S. earth Strip for Transformer neutral connection, the earth strip will be welded to the G.I. pipe and neutral earthing support.
Providing & Fabrication and erection of neutral earthing L Type support made of M.S. Angle size 65x65×6mm. Structure shall be 5.3 Mtr. long with 1 Mtr. Arms. Structure shall be grouted in ratio 1:3:6 in block size 300×300×700mm and painted with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and M.S. Earthing strip with the help of flexible copper bond, M.S. Bolt and washer.
Providing & Fabrication and erection of cable support made of two pieces of M.S. Channel 100x50x6 mm, 3.75 meter long, joined to each other by means of 5 Nos. M.S. Flat (50×6)mm pieces of size 150 mm long each by welding at equal intervals and grouting in a block of size (300×300×700)mm in CC 1:3:6 complete with one coat of ready mixed primer and two coats of Al. paint. Work includes providing of three Nos. M.S. clamps made of (50×6)mm M.S. Flat for holding the cable including nuts and bolts.
Providing & Fabrication of copper bus bar of size (2500×50×6)mm in L.V. side of 5 MVA/10 MVA 33/11 KV, power transformer. Work includes connection of outside bus bar in L.V. side busing rod of Power Transformer and other side with outdoor 11 KV cable box as well as providing empire tape and H.T. tape etc. for proper insulation work.
Installation of 11 KV Switch Gears in Control Room Carefully & safely shifting of 11 KV switch gears from outside to inside the switch gear room grouting foundation of bolts in C.C. ratio of 1:2:4 (including cutting of RCC floor and finishing of RCC floor) as per requirement placing, aligning and fixing of 11 KV anchor GI bolts and nuts of proper size for completion of work.
Proper fixing and making bus bar connection in between two switch gears after proper cleaning. Work also include proper insulation, taping by empire, PVC and H.T. tape etc.
H.T. Power Cable Laying : Laying and dressing of 11 KV 3×300 mm2/3×185 mm2 power cable in air/Trench.
Laying 11 KV, 3×300mm2/3×185mm2 XLPE, Power cable from outgoing switch gear to 11 KV double poles in the cable trench 0.45m wide, 0.90m depth. Providing 150 mm thickness local sand for cushion beneath and 150 mm above the cable (quantity of local sand required 0.375 cubm/m in length). The cable shall be duly protected by brick. On both side of cable by laying bricks vertically and bricks would also be laid horizontally on top of vertically laid bricks along the cable (minimum 18 Nos. per mtr. length are to be laid top and outer side along the cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal's, back filling of earth and testing and commissioning of power cables etc. Spare cable shall be left over and laid in the trenches in shape of 6m rings at both ends. At the end of feeder cables, where the cable is to be laid across pucca/main road, 150 mm dia G.I. pipe will be weared over the cable in the cable trench for the protection of cable.
Preparation of 11 KV Power Cable ends : Making of 11 KV XLPE Heat shrinkable out door jointing kits after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs.
Making of 11 KV XLPE heat shrinkable indoor jointing kits in switch gears after carefully removing the insulation of cable, providing and crimping of proper size of lugs, plumbing and taping of cable with good quality available insulation tape with J/Kit boxes. Fixing and insulating of lugs on cable with switch gear complete in all respect.
wearing of 150 mm dia 3 mtr. long G.I. pipe in the feeder cable of size of (3×300)mm2/(3×185)mm2 XLPE power cable before making the outdoor cable boxes. The work includes the sealing of G.I. Pipe, top end and lower end of the pipe is to be buried in to the ground about ½ m and proper dressing of cable etc. The work includes lifting, mounting and clamping of 11 KV feeder cable boxes on the feeder with double pole structure and making connections including supply of cable mounting clampls etc.
Control Cable Laying Laying of different size of (2×2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to switch gear room, 33 KV CT's to CT's Junction Box, CT 33 KV, 33 KV P.T, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment.
Laying of different size of (4×2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to switch gear room, 33 KV CT's to CT's Junction Box, CT 33 KV, 33 KV P.T, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment.
Construction of 11 KV Double Poles : Excavation of foundation pit in mix soil/normal soil/soft & hard rock and its back filling and leveling etc. The size of the pit will be (900×600)mm and having depth of 1/6th of the full length of the support & Erection of support. The work includes carriage and handling of supports from site store to pit site. 11 Mtr. ST Pole
Erection and grouting of 2 Nos. 11 Mtr. ST Pole pole for making DP Structure including & fabrication fixing of M.S. Channel, M.S. Angle, TPMO, Fuse Set, disc. insulators, pin insulators, stone pad, number plate, danger board, barbed wire etc. The work includes supply and fixing of necessary clamps with nuts, bolts and washers. The work also includes grouting of Double pole support in C.C. 1:4:8 (cement, sand & brick ballast) in block of size (0.45m × 0.45 × 1/6 length of the pole) including earthing of Double pole with M.S. earthing rod complete in all respect.
Grouting of stay rods (16×1800)mm including all work of excavation, cement concrete in size (0.60 × 0.60 × 0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast) as per drg. including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing.
Construction of plinth for the structure of 33 KV VCB as per details Plinth for 33 KV V.C.B. (Qty.- 01) Excavation of earth of size (2.4×1.5×1.0) m pits for construction of plinth.
Brick Ballast ratio (1:4:8) (cement, sand & brick ballast ) for foundation work (2.4×1.5×0.15)m plinth.
C.C. work in ratio 1:2:4 (cement, coarse sand &stone grit) of 20mm size for making plinth of size (2.4×1.5×1.00)m and grouting of foundation bolts 04 Nos. for 33 KV VCB.
12 mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level size (2.4×1.5)m.
Assembling and installation of 33 KV VCB on the VCB out door structure on the plinth.Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes fabrication of addition arrangement for proper fixing, if required.
Construction of fire wall between Transformer (as per Specification)
Construction of Control Cable Trench (as per Specification)
Construction of SSO Approach Road (as per Specification)
Excavation of Earth, Erection of Structure 33 KV Bus Isolator, Grouting and Plinthing of completed Structure with fabrication work if required.
Excavation of Earth, Erection of Structure 33 KV Fuse Set, Grouting and Plinthing of completed Structure with fabrication work if required.
Excavation of Earth, Erection of Structure 33 KV Lightening Arrestor, Grouting and Plinthing of completed Structure with fabrication work if required.
Excavation of Earth, Erection of Structure 33 KV Post Insulator, Grouting and Plinthing of completed Structure with fabrication work if required.
Excavation of Earth, Erection of Structure 33 KV CT, Grouting and Plinthing of completed Structure with fabrication work if required.
Erection of 24 Volt Battery and Battery charger with fixing of fitting
Outdoor switchyard Earthing with 32 mm.size MS round Earth mat with Delta Earthing on power Transformer Nutral & 33 KV LA as per respo specification
Indoor Equipment Earthing
Safe Carriage of dismantled old 5 MVA Power Transformer from 33/11 KV Substation Power T/F Plith to outside of switchyard This includes the following works :– Draining of oil from conservator, radiators of the 5 MVA transformer already available site into the dry & clean drums and stocking at the safe place. Dismantling of conservator, radiators and other accessories from existing 5 MVA transformer. Shifting of 5 MVA transformer main body and others accessories from the Sub-Station switchyard to loading point outside the switchyard to loading point outside the Switchyard. Loading of main tank of transformer alongwith conservator, radiators, transformer oil and other accessories on the trailer/truck. Carriage of transformer conservator, radiators, transformer oil and other accessories Unloading of main transformer body, conserator, radiators, transformers oil and other accessories at unloading point out side the switchyard of 33/11 KV Providing and fixing of 5 MVA Power T/F’s Radiator Sealing Package (16 Each) Cleaning & painting of 33/11 KV, 5 MVA Power Transformer complete with radiators, conservator tank etc. with good quality two coats of assian/narolack make paint after applying one coat of red oxide. Topping up of the transformer oil from drums into the conservator and radiators of the 5 MVA transformer and releasing the air etc. and Transit Insurance of 5 MVA Transformer
Repairing of Existing plinth for New 10 MVA Transformer
Dismantling of Damage 33 KV VCB, CT from Structure and kept aside outside of switch yard
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .