Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.4 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹9.4 L Quoted ₹9.8 L | 1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | 2₹10.4 L+₹63,090 (6.44%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | ₹10.4 L+₹63,090 (6.44%) | 2 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 3 | 3₹10.7 L+₹89,328 (9.12%)Rejected-Finance H O WANI HOUSE II SHOWPORA SRINAGAR J K | ₹10.7 L+₹89,328 (9.12%) | 3 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 4 | 4₹10.8 L+₹1.0 L (10.6%)Rejected-Finance BROADWAY SHIVPORA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | ₹10.8 L+₹1.0 L (10.6%) | 4 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 5 | 5₹11.1 L+₹1.3 L (13.4%)Rejected-Finance | ₹11.1 L+₹1.3 L (13.4%) | 5 | Rejected-Finance BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | RISING SUN ENGG WORKS L5 | national engineering L7 | M/S SHABIR AHMAD SHAH AND CO L6 | SUMEET TRADING CORPORATION L1 | MM ENTERPRISES L8 | M/S ZTECH L2 | LEO TRADERS L4 | M/S WEB COMPNAY L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. | 328 | Per Point | 75 ₹24,600 | 90 ₹29,520 | 80 ₹26,240 | 50 ₹16,400 Lowest | 90 ₹29,520 | 60 ₹19,680 | 70 ₹22,960 | 68 ₹22,304 |
| 2.00 | Taking out old unsv underground cable of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. | 200 | RM | 75 ₹15,000 | 90 ₹18,000 | 75 ₹15,000 | 50 ₹10,000 | 90 ₹18,000 | 60 ₹12,000 | 70 ₹14,000 | 24 ₹4,800 Lowest |
| 3.00 | M&L for Wiring for circuit/submain wiring alongwith earth wire with the 2x10.0 sq. mm + 1x10.0 sq. mm
earth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit all as specified and directed by Engineer in Charge. | 130 | RM | 1,050 ₹1,36,500 | 1,020 ₹1,32,600 | 1,050 ₹1,36,500 | 890 ₹1,15,700 Lowest | 1,070 ₹1,39,100 | 940 ₹1,22,200 | 1,000 ₹1,30,000 | 1,290 ₹1,67,700 |
| 4.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(a) One light point/one fan point controlled by one switch | 182 | Per Point | 1,075 ₹1,95,650 | 1,090 ₹1,98,380 | 1,100 ₹2,00,200 | 930 ₹1,69,260 Lowest | 1,130 ₹2,05,660 | 950 ₹1,72,900 | 1,070 ₹1,94,740 | 1,290 ₹2,34,780 |
| 5.00 | M&L in repair for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size | 56 | Per Point | 1,075 ₹60,200 | 1,090 ₹61,040 | 1,100 ₹61,600 | 1,000 ₹56,000 Lowest | 1,130 ₹63,280 | 1,200 ₹67,200 | 1,070 ₹59,920 | 1,290 ₹72,240 |
| 6.00 | M&L in repair for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(c) One 3 pin 5 Amp socket outlet on same board. | 40 | Per Point | 690 ₹27,600 | 730 ₹29,200 | 700 ₹28,000 | 650 ₹26,000 | 730 ₹29,200 | 700 ₹28,000 | 690 ₹27,600 | 325 ₹13,000 Lowest |
| 7.00 | All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by Engr in Charge. | 50 | Per Point | 1,875 ₹93,750 | 1,890 ₹94,500 | 1,900 ₹95,000 | 1,800 ₹90,000 | 1,890 ₹94,500 | 1,900 ₹95,000 | 1,860 ₹93,000 | 1,680 ₹84,000 Lowest |
| 8.00 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. | 40 | Each | 135 ₹5,400 | 140 ₹5,600 | 132 ₹5,280 | 120 ₹4,800 | 140 ₹5,600 | 140 ₹5,600 | 130 ₹5,200 | 99 ₹3,960 Lowest |
| 9.00 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge. | 222 | Each | 145 ₹32,190 | 160 ₹35,520 | 141 ₹31,302 | 120 ₹26,640 | 160 ₹35,520 | 120 ₹26,640 | 140 ₹31,080 | 32 ₹7,104 Lowest |
| 10.00 | S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge . | 56 | Each | 130 ₹7,280 | 130 ₹7,280 | 131 ₹7,336 | 120 ₹6,720 | 130 ₹7,280 | 140 ₹7,840 | 130 ₹7,280 | 112 ₹6,272 Lowest |
Tender Value
₹9.3 L
EMD Value
₹20,000
Closing Date
9 Feb 2026, 6:00 pmClosed
AGE (I) NIMU
AGE (I) NIMU PIN 901312 C/O 56 APO
SPL REPAIR TO INTERNAL WIRING SUB MAIN WIRING MCB DBS AND LIGHTING AND FIXTURE IN OFFICE COMPLEX AND STORES SHELTER NO T-119 T-120 T-121 DIMENSION OF 22.5M X 6.10M X2.7M OF 108 MED REGT AT NURLA MIL STN UNDER AGE (I) NIMU AND SPL REPAIR FOR REWIR
2026_MES_749231_1
AGE(I)/NIT-60/2025-26
Open Tender
Civil Works
Item Rate
180 days
AGE (I) NIMU
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) NIMU
₹20,000
25 Apr 2026
20 Jan 2026
16 Feb 2026
20 Jan 2026
9 Feb 2026
3 Feb 2026
Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge.
Taking out old unsv underground cable of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge.
M&L for Wiring for circuit/submain wiring alongwith earth wire with the 2x10.0 sq. mm + 1x10.0 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit all as specified and directed by Engineer in Charge.
M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :- (a) One light point/one fan point controlled by one switch
M&L in repair for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :- (b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size
M&L in repair for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :- (c) One 3 pin 5 Amp socket outlet on same board.
All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by Engr in Charge.
S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge.
S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge.
S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge .
S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr in Charge .
M&L for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engr in Charge.
S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXACP7IN1W010 or equivalent in Philips/Crompton) complete all as per specified and as directed by Engr-in-Charge.
S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXAXPNIN1W020 or equivalent in Philips/Crompton) complete all as per specified and as directed by Engr-in-Charge.
S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 16 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr in Charge.
M&L in repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards with all accessories complete all as per specified and as directed by Engr-in-Charge.
Dismantling and Taking down old u/s street / building sequrity Light fittings from poles, flood lights, post top lantern lights and garden lights for replacement with LED fittings all as specified and as directed by Engr in Charge.
Supply and fix in Repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Specified and directed by Engr in charge.
M&L for GI bracket 1.5 mtr long made out of GI pipe 40mm dia bend to suitable radius incl clamps nuts bolts washers incl painting with aluminum paint etc complete all as specified and directed by Engr in charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per specified and as directed by Engr-in-Charge.
Supply and fix in replacement exhaust fan, engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm AC single phase with, blades, and frame and louvers of size 300 mm sweep all as per specified and as directed by Engr-in-Charge.
M & L in repair for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanized earh strip of size 25 x 4 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 8 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr in Charge.
Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300mm sweep heavy duty with, blades, and frame and louvers voltage 230V, 50 Hz, RPM 1200, Copper winding all as specified and directed by Engr in Charge.
Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, and frame and louvers voltage 230V, 50 Hz, RPM 1200, Copper winding all as specified and directed by Engr in Charge.
Wiring for circuit/submain wiring alongwith earth wire with the 2x6.0 sq. mm + 1x6.0 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit all as specified and directed by Engeneer in Charge.
Dismantling old U/S Lt feeder piller box / Busbar chamber incl all outgoing and incoming connection and making good the disturbed area from site all as specified and directed by Engr in Charge.
M&L for Busbar chambers with 4 aluminium busbar strip of rating 400 Amp 6 Way fixed on angle iron of size 40mm x 40mm x 5mm complete all as specified and directed by Engineer in Charge.
Supply and laying or fixing in repair passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core, 10 sq. mm nominal cross section in service connections all as specified and directed by Engr in Charge.
M&L in repair Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm dia by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_839065.xls
BOQ • 0.37 MB
Tender60.pdf
Tender Documents • 2.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .