CWE NAGPUR
Commander Works Engineers Bldg No. P-9, Sitabuldi Fort, Nagpur-440 001 Pin-900419, C/o 56 APO
SPECIAL REPAIR TO INTERNAL E/M SERVICES AND EXTERNAL ELECTRIC SUPPLY OF BLDG NO. 136 MUSEUM AT GRC KAMPTEE
2022_MES_526823_1
84738/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE KAMPTEE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE KAMPTEE
₹13,000
Yes
18 Jul 2022
27 May 2022
25 Jun 2022
27 May 2022
24 Jun 2022
10 Jun 2022
27 May 2022 - 6 Jun 2022
Amount
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 metre depth for foundation, laying of cables/pipes/poles etc., and getting out in Soft/ Loose soils, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm by excavated soil, complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed.
Supply and fixing double wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 50mm outer diameter and 38mm inner diameter with IS 14930 (Part-2):2001,and 6 mm thick laid in trenches/floors and fixed on walls/poles, with and including necessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and directed.
Supply, laying & testing of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured earthed electric power cable (heavy duty) with aluminium conductor of cross sectional area 10 Sqmm, 4 Core.1100 Volts grade suitable for earthed system, laid in trenches / passing though GI pipe / fixed along wall / on pole complete all as specified and as directed. Note: Earth work shall be measured and paid separetely against the respective items.
Supply, laying & testing of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured earthed electric power cable (heavy duty) with aluminium conductor of cross sectional area 16 Sqmm, 4 Core.1100 Volts grade suitable for earthed system, laid in trenches / passing though GI pipe / fixed along wall / on pole complete all as specified and as directed. Note: Earth work shall be measured and paid separetely against the respective items.
Supply and fixing LED fittings, IP65 rated Inverted Pyramid tripod Type LED Bollard with soft 360 degree light distribution 9 W 230 V, 50 Hz complete on suitable PCC 1:2:4 alongwith suitable connectors to connect with 10 sqmm X 4 core cable having protection from water and soil, complete all as specified and directed. Make: BAJAJ cat part No. BGBOS 600 9W LED WW or equivalent in specified makes.
Supply and fixing LED flood light luminaries of capacity 80 watts pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection complete with driver with suitable size Flat iron clamps, nuts, bolts, washers and fixing accessories including taking down old unserviceable fittings, complete all as specified and directed. Make: BAJAJ cat part No. BJFL 80 W LED or equivalent in specified makes.
Taking down unserviceable point wiring with copper/aluminium conductor cable of (light, fan, plug and power plug point) complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fittings, regulator etc, and making good disturbed surfaces of walls/floor etc to match with existing surfaces including white/ colour washing/distempering , complete all as specified and as directed.
Taking down old unserviceable sheet metal enclosure with MCB's ,main switch, etc., and making good the disturbed surfaces of wall , complete all as specified and as directed.
Taking down carefully unserviceable sub main wiring of any size/capacity and making good disturbed surfaces to match with the existing surfaces complete all as specified and as directed.
Material and labour for concealed point wiring 1100 volt grade single core PVC FRLSH insulated and unsheathed cable with multi-stranded copper conductor 1.50 Sqmm drawn in with and including electrical grade heavy duty PVC conduit not less than 20 mm dia with IS 9537 (Part-III) 1983 IS marked, medium grade concealed on wall/ceiling as per site requirement including PVC FRLSH insulated and unsheathed cable with copper conductor of size 1.50 Sqmm as earth conductor and pressed steel modular boxes sunk on wall for mounting modular switches, switch sockets, fan regulator, etc including modular cover with frame of any size, including making good the disturbed surfaces complete all as specified and as directed for one light point controlled by one, one way switch for one light. Note: (i) Cost of cable provided from submain DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. (ii) Quoted rate shall be including the cost of cutting/ chases/ re-plastering and colour etc all as site requirement to be match with existed surface of wall.
All as per Item Sr No. 12 above but for one wall mounted fan point controlled by one No. one way switch and regulator.
All as per Item Sr No. 12 above but for one 3 in 5 Amps socket outlet point on the same board with other switches.
All as per Item Sr No. 12 above but for one 3 in 5 Amps socket outlet point on independent board.
Material and labour for sub main wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in PVC conduit of suitable size with accessories (ISI marked) on wall/ceiling complete all as specified and directed:- 2 run of 4 sqmm PVC FRLSH copper cable and one run of 4 sqmm PVC FRLS copper cable for earth wire , complete all as specified and directed. Note: (i) sub main wiring-2 runs of wire and 1 run of earth wire alongwith PVC conduit will be measured as one unit. (ii) Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.
Supply & fix ceiling rose ,3 Terminal /PVC/polycarbonate ,isolated body surface, all as specified and as directed.
Supply and fix modular switch 1 way 6 Amps, single pole, 250 Volts AC, all as specified and as directed.
Supply and fix modular socket 2/3 pin combined 2 module 6 Amps, single pole, 250 Volts AC, all as specified and as directed.
Supply and Fix Highly durable surface mounted 18/20 watts LED batten / surface constructed of fire retardant engineering grade extruded aluminium body 100 lumen per watt min 2000 lumen and decorative end cap complete with driver including 3 core 1.0 sqmm copper conductor cable for connection drawn through in flexible connection pipe and accessories, complete all as specified and directed. MAke: BAJAJ Cat part No. BCLAB 18 W WH LED P or equivalent in specified makes.
Supply and fix building security light LED 24/25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 1.2 m long and bent in 120 degree including GI clamp made out by 32 X 6 mm GI strip and making all electric connection using 3 core flexible copper cable, two shape including FI clamps nut bolts etc , complete all as specified and directed. MAke: BAJAJ Cat part No. ENXT P24L WH CR PC SD or equivalent in specified makes.
Supply and fix spot decorative LED lights 10 W with 180 degree rotation warm white track mounted and magnetic hinge arrangement including tracks and making all electrical connection using 3 core flexible copper cable drawn through in PVC conduct pipe, complete all as specified and directed. MAke: Jaquar Cat part No. LTRLW1R010XW or equivalent in specified makes.
Supply & fix Sheet metal enclosure SPN for 240 volts 8 way with 200 Amp rated bus bar flush/surface mounting double door, complete all as specified and directed.
Supply & fix MCB SP 6 to 40 Amps, 240 Volts,, breaking capacity 10 KA, C series, complete all as specified and as directed.
Supply & fix MCB SPN 6 to 40 Amps, breaking capacity 10 KA, 240 Volts,'C' series complete all as specified and as directed.
Supply and fix MCCB TPN 415 volts 40 to 63 Amps 16 KA in enclosure connecting including enclosure as original and fixing arrangement as per site 10 sqmm X 4 core FRLSH wire complete all as specified and as directed.
Supply and fix MCB TPN 415 volts 40 to 60 Amps 10 KA 'C' series, complete all as specified and as directed.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth lead wire 4.00mm dia by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40mm bore, medium grade 7.5m long as applicable and as per plate No. 3 of SSR Part-I 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) PCC pit in cement concrete (1:2:4) type B-1 (c) Pre-cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 kg/ sqmm (e) Funnel with watering pipe of GI 20 mm nominal bore ,medium grade & aluminium lug etc. (f) 15mm nominal bore medium grade GI protection pipe upto 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
Supply and fix wall mounted cabin fans modular type 400 mm sweep, copper wounded with cord and hanging arrangement, complete all as specified and as directed. Make: Bajaj / Orient/ Crompton as approved by GE.
NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.8,018.00 /- ]
VIJ ASSOCIATES
Paragon Electrotechnics
Vaidehi E Link
Chinmaya Enteprises
Bidder Name
Paragon Electrotechnics
Chinmaya Enteprises
Vaidehi E Link
VIJ ASSOCIATES
M/S. ELECTROPOWER TECHNOLOGIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .