Zirconium Complex, Pazhayakayal
Annual Civil Maintenance of Various Plant buildings at Zirconium Complex, Pazhayakayal, Tuticorin 628152
2023_NFC_742287_1
ZC/NFC/CIVIL/796/2023
Open Tender
Civil Works
Item Rate
365 days
Zirconium Complex, Pazhayakayal
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹1.7 L
Yes
14 Mar 2023
2 Mar 2023
14 Mar 2023
2 Mar 2023
11 Mar 2023
4 Mar 2023
Amount
Upto 1.50 m depth from average ground level.
From 1.50 m to 3.00 m depth from average ground level.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete as directed by EIC.
Cement concrete 1:3:6 using Portland Slag Cement (PSC) conforming to IS 455 (M/s. ACC, Ultra Tech,Chettinadu, Coramandal, KCP or equivalent), crushed stone sand, graded stone aggregates of 20 mm maximum size at and at all depths below plinth level including consolidation, finishing smooth/broom finish as applicable, curing, etc., complete but excluding formwork as per specifications and direction of EIC.
Random rubble stone masonry using approved local stones in foundations/pedestals and plinth at and at all depths below finished floor level in cement mortar 1:6 (1 cement : 6 Crushed Stone Sand) including simultaneous flush pointing with the same mortar, bond stones, curing, etc., complete as specified and directed by EIC.
Reinforced Cement Concrete by insitu mixing using Weigh Batching or approved RMC source of Grade M - 30 (Minimum Cementitious Content not less than 340 Kg/Cum) up to specified level using Portland Slag Cement (PSC) conforming to IS 455 Part-1 (M/s. ACC, Ultra Tech,Chettinadu, Birla, Coromandal, , KCP or equivalent make) with manufactured/robo sand and graded stone aggregates of 20mm maximum size including mixing superplasticizer of brand M/s. Fosroc, Demech, Huntsman, Pidilite, Sunanda Chemicals, Agro Chemicals, MBT or equivalent make in proportion as per Manufacturer's Specifications, Pumping / Lifting of concrete to the required heights, Concrete laid to proper level, profile and slope, placing concrete, consolidation, finishing, curing, etc., but excluding Formwork as specified and directed by EIC.
Upto Finish Floor Level
Above Finish Floor Level for all Heights
Reinforced Cement Concrete (RCC) by insitu mixing using Weigh Batch or approved RMC Mix of Grade M - 20 (Minimum Cement Content 300Kg/Cum) using using Portland Slag Cement (PSC) conforming to IS 455 Part-1 (M/s. ACC, Ultra Tech,Chettinadu, Birla, Coromandal, , KCP or equivalent make) with manufactured/robo sand and graded stone aggregates of 20mm maximum size, Concrete laid to proper level, profile and slope in panels of convenient size by alternate/staggered panels, placing concrete, consolidation, finishing, curing, etc., for Grade Slab, etc. as per the specification and as per the direction of EIC.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete as per the direction of EIC.
Providing and laying 150mm thick dry stone pitching/ soling using hard stone including surface preparation, filling the interstices with coarse aggregate etc complete as per the specification and as directed of EIC.
Supplying, Fabricating, erecting / fixing in position Reinforcement for reinforced cement concrete items at all depths and heights below and above plinth level with high yield strength deformed bars conforming to IS 1786, Fe 500D with TM Treatment from approved source (Vizag steel, Tata, SAIL, Jindal or equivalent make) including transporting steel to site, loading , unloading, decoiling, straightening, cutting, bending using rod bending machine , fixing and tying in position with two strands of 18 gauge soft drawn annealed MS binding wire, providing cement mortar cover blocks in CM 1:1, etc., complete as per specifications and as directed by the EIC.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per the direction of EIC.
Providing formwork (centering and shuttering) using timer planks/steel plates at and at all depths and heights below and above plinth level, in vertical, horizontal and inclined plates including propping and bracing using Acro pipes or steel tubular staging, stripping for in-situ reinforced and plain cement concrete work as required, chamfers, splays, keys, wedges, nails, bracings, brackets and applying a coat of shuttering oil on all contact surfaces with concrete, hacking the surfaces in contract with masonry after stripping etc., complete as specified and directed by EIC.
Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Brick work in foundation, plinth and superstructure using quality bricks of class designation 7.5 using cement mortar 1:6 (1 cement :6 using crushed stone sand of grade conforming to BIS 2116) at and at all depths below & above plinth level, simultaneous pointing with same mortar below ground level, and ranking out joints above ground level, curing etc., complete as per specifications and as directed by EIC.
Brick work in super structure using quality clay bricks of class designation 7.5 conforming to using cement mortar 1:6 (1 cement :6 using crushed stone sand of grade conforming to BIS 2116 ) at all heights above plinth level including pilasters, scaffolding, raking out joints, curing etc., complete as per specifications and as directed by EIC.
Cement plastering 6 mm thick for ceiling with cement mortar 1:4 finished smooth finish including hacking of concrete surfaces, preparation of surface, steel/tubular scaffolding, curing, etc., complete as directed by EIC.
Cement plastering 15 mm thick for internal walls in cement mortar 1:4 (1 Cement : 4 Crushed Stone Fine Sand) finished smooth at and at all heights above plinth level over brick walls or concrete surfaces including making necessary grooves in between junctions of brick masonry and RCC and also other places wherever required over brick walls or concrete surface, preparation of surface, scaffolding, curing, etc., complete as directed by EIC.
Sand faced plaster 20 mm thick in 2 coats over exterior masonry and concrete surfaces at and at all heights above plinth level as given below with base coat in cement mortar 1:4 with 12 mm thick and finishing coat in CM 1:3, 8 mm thick, final rendering, making necessary grooves, bands, drip moulds as required, double steel/tubular scaffolding wherever necessary, hacking of concrete surfaces, curing, etc., complete as directed by EIC.
Providing and applying white washing with lime to give an evenshade including the blue and gum if required, man power, tools & tackles etc. Complete as per specification and as per the direction of EIC. (Note: The moving scaffolding set available with Dept. can be utilised on free of cost)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer of Asian, Pidilite, Johnson & Nicklson, Nerolac, berger or equivalent brand, of required shade and colour over one coat of approved cement primer at all heights above plinth level including preparing the plastered surfaces, steel/tubular scaffolding and cleaning etc., complete and as specified and directed by EIC.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth at all heights above plinth level including preparing the plastered surfaces, steel/tubular scaffolding and cleaning etc. complete as directed and specified by EIC.
Painting exterior walls on sand faced plaster with two coats of antifungus acrylic emulsion paint of exterior quality having 100% acrylic of Asian, Pidilite, Johnson & Nicklson, Nerolac, berger or equivalent brand of approved shade including preparing surfaces filling cracks with external crack filler of Birla or any approved equivalent, applying one coat of approved primer as per manufacturers specification, filling cracks or wherever required for external filler, curing, scaffolding, cleaning, etc., complete and as specified and directed by EIC.
Painting two or more coat with synthetic enamel paint of approved brand and manufacture to give an even shade on new work over the coat of ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works etc. complete as per the specification and as directed by the EIC.
Providing and applying two coats of approved best quality Anti-Corrosive Bitumen based paint conforming to IS: 9862 over one coat of compatible primer of approved brand on exterir surfaces of underground concrete surfaces of structures below plinth/FFL including preparing the surfaces, filling cleaning etc., complete as specified and directed by EIC.
Providing and fixing in position single leaf flush door shutters of solid block board core, 35 mm thick, at all heights above plinth level internally lipped with second class teakwood, 25 mm deep along all edges of shutters bounded with water-proof type phenol formaldehyde synthetic resin, hot pressed, Chemicaly treated and with commercial ply finish on both faces providing and fixing under pressure with approved type adhesive 200 x 150 mm laminated sheet on both sides where mortice lock is fixed including providing and fixing 2nd class teak wood rebate at meeting junction of shutters in case of double door shutters, fixing hinges supplied under relevant item to shutter and frame as specified and directed by EIC.
Providing and fixing Anodised aluminium work for frames and shutters of doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required etc. complete. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the direction of EIC.
Providing and fixing glazing with float glass panes of 4.0 mm thickness in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of EIC.
Providing MS grills using 10mm square bars incuding welding to flat of requisite size fixing the grills in postion as requires and directed by EIC.
Supplying only approved anodized extruded aluminium heavy quality butt hinges with S.S. pin generally conforming to IS specifications Classic, Jyothi or approved equivalent make) of size 125 x 63 x 4 mm with cadmium plated wood screws of appropriate size etc., complete as directed by EIC.
Supplying and fixing to wooden doors etc. and at all heights above plinth level approved anodized extruded aluminium tower bolts using 250 mm long, 10 mm shoot conforming to relevant IS specifications (Classic or its approved equivalent) with approved cadmium plated brass screws of appropriate size etc., complete as directed by EIC.
Supplying and fixing to wooden doors approved anodized aluminium aldrop conforming to relevant IS specifications and with ISI marking classic/ J.S.E. (ECIE) or any approved equivalent of size 250 x 16 mm with suitable approved CP brass screws, machine screws or bolts for securing clamps from inside etc., complete as directed by EIC.
Supplying and fixing to wooden doors at all heights above plinth level approved anodized extruded aluminium handles with round grip and face plate conforming to relevant IS specifications and with ISI marking Classic/Jyothi or approved equivalent make and of size 150 mm (grip) with approved cadmium plated screws of appropriate size etc., complete as directed by EIC.
Supplying and fixing to wooden doors at and at all heights above plinth level approved best quality anodized extruded aluminium door stoppers twin type with rubber cushion (JSE (ECIE) make or approved equivalent), with approved cadmium plated brass screws of appropriate size, etc., complete as directed by EIC.
Providing cement based waterproofing treatment to new terraces an average thickness of 110 mm (minimum 65 mm thick at outlets) in cement mortar not leaner than 1:4 including cleaning the concrete surfaces, giving injections to the top slab as required with cement and approved waterproofing compound solution to fill up all inherent holes, voids, honey-combs, etc., in the concrete slab, setting brick bat coba in waterproof mortar with necessary gradient for easy flow of water and continue the treatment along the inner faces of parapet or other adjoining wall upto a height of 300 mm in the shape of Vatas, finally treating the top surface and Vatas with waterproof plaster finished smooth with trowel in cement colour with false markings of 300 mm squares etc., generally as indicated in drawings and as per manufacturers specifications and enclosed specifications whichever is superior as directed by EIC. 1)The treatment shall be tested by ponding water for a period of 10 days. If due to location of rain water pipes the average thickness of treatment exceeds 110 mm for easy flow of water the extra brickbat coba will be paid as extra item and the rate for the same to be got approved from the Department before execution. 2) The waterproofing treatment is to be guaranteed for bone-dry condition for a period of 10 years in the prescribed proforma. 3) The measurement for payment shall be the entire area of terrace covered by the treatment measured between brick/concrete parapets without plaster and the area of vatas calculated by taking the length of vatas and the height above the finished level of the terrace.
Supply and laying of Acid resistant bricks 230*115*38 mm thick confirming IS 4860 Class -1 including the application of Bitumen primer as per IS 158-1981 over that laying bed mortar with Si - K mortar of Potassium silicate and joints are pointed with furnace mortar etc.complete as per the manufacturer specification and as per the direction of EIC.
Dismantling stacking the damage Acid resistant tiles and stacking the same at 50 M lead, Cost of the item includes the Manpower, Tools & tackles & etc all in complete as per direction of the EIC.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of EIC.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of EIC.
Dismantling Asbestos Cement sheet roofing including ridges, hips, valleys and gutters and stacking the material within 50 metres lead etc. Complete as per specification and as per the direction of EIC.
Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required etc. complete as per specification and as per the direction of EIC.
Providing and fixing Corrugated serrated adjustable ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete as per specification and as per the direction of EIC.
Providing, erecting and removing pipe scaffolding making cubical type with pipes, bracings, brackets, along with ladder with handrail, working platform and intermittant halting to reach the top for carrying out the works etc. complete as per specification and as per the direction of EIC.
Providing and fixing on wall face unplasticised Rigid PVC Single socketed 110mm dia. rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion etc.all complete as per specification and as directed by the EIC.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by EIC) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .