| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC F 20 SHASTRI NAGAR DELHI52 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.4 L+₹8,790 (0.86%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.4 L+₹13,575 (1.32%)Rejected-Finance SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance L3 |
Tender Value
₹11.3 L
EMD Value
₹23,850
Closing Date
27 Jun 2022, 11:00 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, defence Colony, New Delhi 110024
Repair and improvement of E.I, Fans and Compound Lights at Mahavir Vatika Community Centre in ward no 55-S under Central Zone in SDMC
2022_SDMC_119576_1
EE(Elect.)/CNZ/2022-23/09-01
Open Tender
Electrical Works
Item Rate
60 days
C-Block, Defence Colony, New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹23,850
16 Jan 2024
18 Jun 2022
27 Jun 2022
18 Jun 2022
27 Jun 2022
18 Jun 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required: Group-C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required: Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required: 6 Module (200 mm x 75 mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required: 8 Module (125 mm x 125 mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required: 12 Module (200 mm x 150 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: 5/6 Amp switch
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 8 way Double Door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 12 way Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required: 63 A
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: 40 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required: 63A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 x 2.5 sq mm + 1 x 2.5 sq mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 4 x 2.5 sq mm + 2 x 2.5 sq mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 x 6 sq mm + 1 x 6 sq mm
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as required: Upto 450 sq mm sweep
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supply of 12" (300 mm) sweep 1400 RPM exhaust fan heavy duty complete with shutter, blade etc as reqd
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
SITC of LED tubelight luminaire 20W rating complete with extruded Al batten prewired with high efficient LED with the following: (a) Total system wattage 20W+/-5% (b) Luminous efficiency Lumens/Watt >=95 © Power factor >= 0.95
P/F hot press sheet moulded compound (SMC) fire retardent (Temp resistance upto 200 C), IP55 weather proof pole box of inner dimension 200x160x98 mm complete with suitable arrangement for fixing of 2 no of 6-32 A SP MCB & 63A DP isolator (MCB/isolator excluded) with neutral link duly shorting on DIN channel with 2 nos of MS clamps with SS black plate of suitable size with danger monogram properly printed on the cover etc as reqd.
S/o XLPE insulated PVC sheathed Al conductor armored cable 1.1 kV grade confirming to IS-7098of foll size: 4 x 25 sq mm
S/o XLPE insulated PVC sheathed Al conductor armored cable 1.1 kV grade confirming to IS-7098of foll size: 2 x 10 sq mm
S/o XLPE insulated PVC sheathed Al conductor armored cable 1.1 kV grade confirming to IS-7098of foll size: 3 x 6 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required: Upto 35 sq mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required: Upto 35 sq mm
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required: (a) 125A, 36kA, 4P MCCB
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover pla te having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required: (a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
P/L including HDPE pipe of 40 mm outer dia with PN rating 4 by hand molling/manual method confirming to IS 4984
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.Logo/Name of manufacturer shall be embossed on the pole.Galvanization as per relevant IS 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts of size 16mm dia and 600 mm long,J type i/c 2 nos. template anchor plates of size 225x225x3 mm and providing DCW HDPE for cable entry and exit as required for 3m and 5 mtr pole.
Fabrication supplyiing and fixing B-class Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
The Electrician
Aviadu energy and infra pvt ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .