| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.0 LAccepted-AOC 30 20 ATHIPALAYAM ROAD CHINNAVEDAM PATTI POST COIMBATORE 641 006 TN | COIMBATORE | COIMBATORE | TAMIL NADU | 641006 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹82.9 L+₹5.9 L (7.69%)Rejected-Finance 2 375 ARAVENU POST KOTAGIRI THE NILGIRIS TAMIL NADU 643 201 | KOTAGIRI | THE NILGIRIS | TAMIL NADU | 643201 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹83.0 L+₹6.0 L (7.79%)Rejected-Finance 121004 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹84.0 L+₹7.0 L (9.14%)Rejected-Finance 7 345 C 1 AERO NAGAR KANGEYAMPALAYAM KADAMPADI SULUR COIMBATORE TAMIL NADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹84.3 L+₹7.3 L (9.49%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹77 L
EMD Value
₹1.4 L
Closing Date
9 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF ALL WEATHER SHELTERS OVER TECH AND KADAMPADI GATES AT AF STN SULUR
2022_MES_507135_1
8461/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹1.4 L
Yes
22 Mar 2022
10 Feb 2022
10 Mar 2022
10 Feb 2022
9 Mar 2022
3 Mar 2022
10 Feb 2022 - 2 Mar 2022
60 days
Amount
SCHEDULE A BOQ
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed
M & L Plain Cement Concrete 1:4:8, type D-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
S & F TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending and binding spirally for hooping for columns, hooking ends with mild steel wire not less than 0.9 mm dia complete all as pecified and as directed.
S& F TMT bars 6mm to 8 mm dia cut to length as in stirrups/spacers, bent to shape required, including cranking bending and binding spirally for hooping for columns, hooking ends and anneled with mild steel wire not less than 0.9 mm dia complete all as pecified and as directed.
M & L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , straight rough finished surfaces complete all as specified and as directed
M & L formwork to sides of pillars, posts, struts, piers, columns straight rough finished surfaces complete all as specified and as directed.
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in footing foundation beams, plinth beams,bases for columns etc and mass concrete etc complete all as specified and as directed
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in columns , pillars, post and struts etc complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated surplus soil to a distance exceeding 1.50 km but not exc 5 km and depositing where directed complete all as specified and as directed
S & F Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete all as specified and as directed
S & F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe- 290 (Gde E- 165) complete all as specified and as directed
S & F Mild Steel base plates & cleats (Chequred or plain) channels, squared cut or notched (Ordinary and counter sunk) forming holes for nuts and bolt or welded attachment conforming to Fe-410- W(Gde E-250) quality- 'A' including mild steel Anchor Nuts & Screw bolts of size 20mm dia 400mm long (machine made) with hexagonal or square heads complete all as specified and as directed
S & F Mild Steel Anchor bolts made with hexagonal or squre head one end and screwed other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exc 300mm long and 20mm dia complete all as specified and as directed
M&L Pre-painted Galvalume corrugated roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet, any colour, having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Note for Pre-painted coloured Galvalume roofing (Item No 17 & 18) :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
S & F Mild steel bands straps, supports or stays for rainwater, ventilating pipes and gutters including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed
M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Note for item No 25 :- (a) All synthetic enamel paint, shall be of 1st quality of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards.
(d) Paints shall be obtained directly from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers:- i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thick (above or below the ground level) complete all as specified and as directed.
M&L 50 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in base concrete for laying floor finishes complete all as specified and as directed.
M&L Chequered cement concrete tiles 20cmx20cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6) including complete all as specified and as directed
Note for Item No 36 : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing.
M & L for 32 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings as laid in trenches/fixing on walls complete all as specified and as directed. Make : SFMC, Prince, KPT
M & L for 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings as laid in trenches/fixing on walls complete all as specified and as directed. Make : SFMC, Prince, KPT
Note for item No 38 & 39 :- (a) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc.
(b) For pipes laying in trenches, excavation earth work shall be measured and paid seperately under relevant item.
(c ) Wall thickness of pipes shall be all as per IS : 15801
Removing excavated soil to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 500mm depth but not exc 1mtr depth, wide 800mm including making good existing surface with PCC 1:2:4, type B-1, using 20mm graded stone aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 44 :- The unit quoted rate is deemed to be included for the following :-
(i) Earth work excavation in any type of soil/ PCC/ BT road
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in road
(vi) Cost of pipe will be measured and paid separately as supply only.
Supply and fixing 32 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends complete all as specified and directed.
Supply and fixing 25 mm dia PP-R ball valves (brass insert) complete all as specified and directed.
Supply and fixing PVC tank connector with check nuts for inlet pipe of 25mm dia complete all as specified and directed
M&L Rotational moulded polythene water storage tank of 500 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I complete all as specified and directed.
M & L for cutting the existing GI/PPR pipe size 40/50 mm and making Tee joint for taking branch connection including GI/PP-R fitting such as Tee, Union etc complete all as specified and as directed.
M & L Cutting and removing existing rusted and damaged OH tanks hand rails with stand posts and material and Labour fabricate for Compound girders and stanchions, lattice girders, aerial masts, staging of water tank and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250), with square /round or any shape and sizes of MS pipe including two coats of synthetic enamel painting over a coat of red oxide, with scuffolding complete all as specified and directed.
Note for Item No 57 : The unit rate is deemed to be included for supporting to existing water line pipe any description of pipe provided at roof level
M&L for plain cement concrete 1:3:6, type C-1 using 20 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Supply , install , testing and commissioning of Automatic Boom barrier AZ- BB114 Open type -up/down, Auto close type, Rated Power–60W, Accessible through Push button, remote. Kit includes AC Motors set 1, Remote Controller 2, Photocell Sensor 1set, Accessories set 1, 6M/4M barrier ARM 1, Push button 1, Boom Holder
M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including supply and laying HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 6 sq mm 3 core, 1100 Volts grade.
Supply, installation & commissioning of water cooler stainless steel body, electric driven, single phase having storage and nominal cooling capacity of 40/ 80 ltrs complete all as specified and directed. Make : Blue Star/ Voltas/ Hitachi.
Note for item No 63 :- The Contractor shall given a written guarantee of minimum two years from completion of work.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V - 285V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed. Make :- V-Guard/ Microtek/ AE.
M&L Sub main wiring for circuit complete with 2 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable PVC Casing Capping / PVC rigid conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc complete all as specified and directed. Make:- Havells/ Polycab/ Plaza.
Note for item No 66 :- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC casing capping/PVC rigid conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F metal clad socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps complete all as specified and directed. Make :- Legrand /Siemens/ Schnieder.
M & L for point wiring complete with 2.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl pvc conduit Concealed with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with plastic laminated top cover 2.8mm fixed with cadmium plated iron screws etc and 2.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly complete all as specified and directed for the following:-
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 70 here in before but for One 3 pin socket out 5 amp independent,with cables 2.5 sq.mm size
All as per Item No 70 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
S&F modular switch 1 way 6 Amps, 1 module complete all as specified and directed.
S&F modular switch 1 way 16 Amps, 1 module complete all as specified and directed.
S&F modular socket outlet multipurpose 2/3 pin 6 amps, 2 module complete all as specified and directed.
S&F modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module complete all as specified and directed.
S&F white cover plate with frame, 3 Module complete all as specified and directed.
S&F white cover plate with frame, 6 Module complete all as specified and directed.
S&F white cover plate with frame, 8 Module complete all as specified and directed.
S&F metal flush box 3 module complete all as specified and directed.
S&F metal flush box 6 module complete all as specified and directed.
S&F metal flush box 8 module complete all as specified and directed.
S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing sheet metal enclosure powder coated ,MCCB DB, 'G' frame TPN vertical D/D, 4 way including one number MCCB, three pole, 160A, 25KA for incoming bus bar, neutral links, blanking plates etc, all as specified and directed Make Havell's cat art No DHDLVDRWGOFO04 or eauivalent
S&F MCCB four pole, 125 Amp ultimate breaking capacity 16 KA, 415 V complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Siemens/ Schnieder.
M&L Sub main wiring for circuit complete with 2 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable steel conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc complete all as specified and directed. Make:- Havells/ Polycab/ Plaza.
Note for item No 90 :- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and steel conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Material and labour, earthing complete with copper earth plate electrode of size 600mm x 600x 3.15 mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level),with top edge of earth plate not less than 1.5m below normal ground level, eart plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, magnesium sulphate (1 : 1 : .5), electrode connections using copper strip of size 20 x 3 mm thick (upto body of equipment) by means of brazing / welding conencted to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40mm dia bore nd watering pipe 20mm dia bore GI medium grade with funnel and wire mesh including all neesary(excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in elctrical plate No 3 of MES schedule Part-I (2009), testing on completion, complete including dismantling of exisitng earthing all as specified and directed.
Note for Item No 93 :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM not less than 4Kg/ Sqm.
(ii) PCC pit cover shall be constructed 500mm away from the edge of earth pit.
(iii) Copper strip upto 7.5 Mtrs shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately.
(iv) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.
(v) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vi) Earth resistance should be less than 3 Ohm, In case the test results are not found below 3 Ohm, complete earthing will redone without and extra cost to Govt.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and as directed. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. The rate is deemed to be included.
S&F Fly ash bricks using moduar bricks as in cable protection cover of any size complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated , PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated , PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed.
Supply only GI pipe 50 mm bore light grade for cable protection complete all as specified and as dierced Make : Tata, Jindal, Surya Prakash
Note for Item No 105 : The unit rate is included for supply only and cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
S&F Wall mounting Air circulator fan 400 mm Sweep complete all as specified and as dierced Make:-Cat pt No AC 600 Wall -1 of Cromption or Equavelent, complete all as directed
Supply and fix Digital Timer with Analog time ,contactor pre wired Distribution Board complete time lite 32A 3 Pole 230 v complete all as specified and as dierced Make:- Indo asian cat pt No TL032dbo Or equivalent
Supply and fix Cable Junction Boxes with terminals IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry)complete all as specified and as dierced Make : Hensal Cat part No KF 1616 G or equivalent
G Perumal and co
Neptune Engineers and Builders
p.chinnasamy
Lucky Enterprises
DANDU CONSTRUCTIONS
KSR AND COMPANY
devan enterprises
KRISHNA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .