Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹108.4 CrAdmitted-Finance B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | -17.90% | ₹108.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹116.0 CrAdmitted-Finance | -12.15% | ₹116.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹118.5 CrAdmitted-Finance | -10.21% | ₹118.5 Cr | L3 | Admitted-Finance |
| 4 | L4₹131.9 CrAdmitted-Finance AHEMDABAD B WING 15TH FLOOR PRIVILON BUILDING VIKRAM NAGAR AMBALI BOPAL ROAD BEHIND ISCONTAMPLE AHEMDABAD 380058 GUJRAT INDIA | AHMADABAD | GUJARAT | 380058 | -0.09% | ₹131.9 Cr | L4 | Admitted-Finance |
Tender Value
₹132.0 Cr
EMD Value
₹1.3 Cr
Closing Date
4 Apr 2026, 4:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Construction Circe, U.P. Jal Nigam (Urban), Varanasi
construction of Over Head Tanks, CWR cum Pump house, SCADA Automation of all CWR, Rising Main, Distribution Network, House connection, Boundary wall, MS gate, site development work
2026_UPJNM_1122623_1
350/ 08-081-005 / 83 Dated 28.02.2026
Open Tender
Water Supply
547 days
CIS Varuna Area
Please refer to NIT/Tender Document
2 documents required · 2 mandatory
₹23,600
EE, CD-I, UP Jal Nigam (Urban)
₹1.3 Cr
SE, CC, UPJN(U), Varanasi
17 Apr 2026
7 Mar 2026
4 Apr 2026
7 Mar 2026
4 Apr 2026
7 Mar 2026
13 Mar 2026
Civil Work
OVERHEAD TANKS
Investigate the soil bearing capacity by only nationalised institute and If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity. Design, Supply of all materials labour T&P etc. required for complete construction of R.C.C. Over Head Tank of following capacity and staging as specified in bid document as per direction of Engineer-in-charge. The key feature, but not limited to, pertaing to design and construction of OHT are as follows: 1. The finished floor level of OHT shall be min 0.3m above the finished ground level of the campus. 2. Soil investigation and bearing capacity. 3. Structural design and drawing confirming to IS: 456, IS: 3370, IS: 1893, IS: 875 & Other relevant IS Code. 4. Grade of concrete M30 for water retaining structure and concrete grade for other components shall not be less then M25. 5. Saprete two column based RCC stair case of width minimum 1m. 6. 1m wide R.C.C. M30 balcony, SS ladder inside the tank from top dome to bottom dome shall be made of 50x50x6 mm angle section with hand rails of 20mm SS pipes. The grade shall be SS 316. 7. Railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m. 8. Proper ventilator at top dome in circular shape of 1.2 m dia.
9. Food Grade epoxy coating of FOSROC / Ciba-Geigy or reputed brand on inside surface area of water container after testing of water tightness, two coat of apex painting over one coat of primer of approved colour after finishing of RCC surface with grinder. 10. Repairs of pin holes, unevenness of all concrete surface. 11. Ultra Sonic Water level indicator fabricated with sensor connecting to automation 12. Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309‐1969 and ISS 3013‐1966. 13. C.I. manhole of min 60x60cm size with locking arrangement. 14. Supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout with Bell Mouth as per latest / relevant I.S. specifications with all jointing materials for proper completion of work. 15. Construction of 120mm thick RCC floor in 1:1.5:3 with cement, coarse sand, approved stone grit and reinforcement t@8mm dia @250mm c/c both way over 100mm thick PCC 1:4:8. 16. Supply, fixing of D/F Sliuce Valve with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest / relevant I.S. specifications with all jointing materials for proper completion of work. 17. Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing. 18. Supply of 200 mm dia PVC pipe for disposal of water from washout chamber to suitable point outside the water works compound.
19.MS steel box type enclosure of at the entrance of the staircase having locking arrangements. 20.The C.I (D/F)pipe dimensions for inlet,outlet,washout,overflow will be decided as per site requirements. For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determined after soil investigation / 8 tonne/sqm Note :- The bid price of Over Head Tanks is to be submitted considering that the design of over head tank will be done by retired / working Associate proffessor of any IIT and it shall be vetted by a working professor also of IIT and The net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work.
Construction of R.C.C. Over Head Tank 2600 KL/27 mtr including all Materials, Labours, T & P etc. Complete. For Zone-2
Construction of R.C.C. Over Head Tank 2600 KL/29 mtr including all Materials, Labours, T & P etc. Complete. For Zone-3
Construction of R.C.C. Over Head Tank 3100 KL/27 mtr including all Materials, Labours, T & P etc. Complete. For Zone-5
Construction of R.C.C. Over Head Tank 2800 KL/29 mtr including all Materials, Labours, T & P etc. Complete. For Zone-6
Construction of R.C.C. Over Head Tank 3300 KL/29 mtr including all Materials, Labours, T & P etc. Complete. For Zone-7
Construction of R.C.C. Over Head Tank 1600 KL/29 mtr including all Materials, Labours, T & P etc. Complete. For Zone-8
Construction of R.C.C. Over Head Tank 3100 KL/29 mtr including all Materials, Labours, T & P etc. Complete. For Zone-9
Construction of R.C.C. Over Head Tank 3100 KL/29 mtr including all Materials, Labours, T & P etc. Complete. For Zone-10
Repairing of RCC Over Head Tank- 1250 KL/18 m Staging of Water Campus of Zone-1 including all materials, labour, T&P etc complete for proper completion of work as per instructions of Engineer -in -charge.
Repairing of RCC Over Head Tank- 1000 KL/18 m Staging of Water Campus of Zone-4 including all materials, labour, T&P etc complete for proper completion of work as per instructions of Engineer -in -charge.
C.W.R. CUM - PUMP HOUSE
Supply of all materials, labour and T&P etc. complete for the construction of Ground RCC CWR cum pump house of following capacities & with 1.00m wide R.C.C. with minimum reinforcement appron alround with 20 cm semi circular P.C.C. drain M.S. ladder with hand rails out side and inside the tank body proper ventilators at top, water level indicator, Lightening conductor as per latest I.S.I. or electricity rules, 1150mm dia medium pattern C.I. Manhole cover hinged with locking arrangement fixing and jointing vertical DID/F, pipes, specials and duck foot bents of required size for inlet, outlet fising of outlet sluice valve and wash out sluice valves with all jointing materials for proper completion and other appurtenant works including excavation in all type of soil & in rock etc. painting on exposed water proof cement paint, painting of pepes and ladder with approved anticorrosive paints also including testing of the CWR including carriage of construction materials by truck/ head load etc. upto site of work. For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determined after soil investigation / 8 tonne/sqm Note :- The bid price of CWR cum Pump House is to be submitted considering that the design of CWR cum pump House will be done by retired / working Associate proffessor of any IIT and it shall be vetted by a working professor also of IIT and The net safe allowable bearing capacity as 8 t/m2.
175 KL, For Zone 1
650 KL, For Zone 2
650 KL, For Zone 3
200 KL, For Zone 4
800 KL, For Zone 5
400 KL, For Zone 8
800 KL, For Zone 9
Repair of 61.50 KL CWR in Zone -1 including all materials, labour, T&P etc complete for proper completion of work as per instructions of Engineer -in -charge.
Repair of 61.50 KL CWR in Zone -4 including all materials, labour, T&P etc complete for proper completion of work as per instructions of Engineer -in -charge.
Rising Main
Supply of following sizes (D.I.) pipes for rising main/distribution system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as specials conforming to latest /relevant I.S. specifications, suitable for D.I pipes, as per IS-1239 /2000 and IS 8329/2000 or their latest amendment including F.O.R. destination and all taxes and insurance etc. with loading, unloading
250 mm dia D I K-9
300 mm dia D I K-9
350 mm dia D I K-9
400 mm dia D I K-9
Excavation of earth in ordinary soil (loam, clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 m and refilling watering, ramming of the excavated earth into the trench and also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour, T&P etc complete as per instructions of Engineer -in -charge.
Carting, laying and jointing of the following sizes of pipes into the trenches including cost of all jointing materials, labour and T&P, testing etc. complete.
250 mm dia D I K-9
300 mm dia D I K-9
350 mm dia D I K-9
400 mm dia D I K-9
Dismantling of the following type of road surface for laying of pipe line including sorting out and stacking of serviceable materials and disposal of unserviceable materias. as per instructions of Engineer -in-charge.
Interlocking Road
Bituminous Road
Permanent re-instatement of the following ty pe of road surface after laying of pipeline including supply of all materials, labour, T&P etc. required for completion of work. it also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning surface for proper completion of the work as per directions of Engineer ‐in ‐charge.
Bituminous surface (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20%
Interlocking Road (existing usable Interlocking bricks M-30 grade, on 20cm local sand & 10cm TH. PCC 1:6:12). Incl. Entire surface Spreading 3 cm local sand for paste of brick & joint filling
Supply of the following sizes of C.I. Double flanged sluice valves and tail peace as per I.S. 780/1969 class-1 working pressure 10kg/sqcm F.O.R destination
Sluice Valve PN 1.0 dia 250mm ( By Pass Arrangement)
Sluice Valve PN 1.0 dia 300mm ( By Pass Arrangement)
Sluice Valve PN 1.0 dia 350mm ( By Pass Arrangement)
Sluice Valve PN 1.0 dia 400mm ( By Pass Arrangement)
carting laying and jointing with fixing in proper position of the following sizes of C.I. Double flanged sluice valves and tail peace as per I.S. 780/1969 class-1 working pressure 10kg/sqcm including lowering, fixing in position and jointing then with pipe line etc comlete including all jointing material and specials of following sizes.
Sluice Valve PN 1.0 dia 250mm ( By Pass Arrangement)
Sluice Valve PN 1.0 dia 300mm ( By Pass Arrangement)
Sluice Valve PN 1.0 dia 350mm ( By Pass Arrangement)
Sluice Valve PN 1.0 dia 400mm ( By Pass Arrangement)
Sluice valve chamber (Massonary Type)
Design and construct Thrust Block made in R.C.C. with cement coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 for pipe line including supply of MS reinforcement wrought to required shape as necessary its bending fixing & binding the same with 0.50 mm thick binding wire in position & necessary centering & shuttering including curing and supply of all materials labour T & P etc. required for proper completion of the work and as per specifications for RCC work as per instructions of Engineer -in -charge.
Supply of MS reinforcement wrought to required shape as necessary its bending, fixing & binding the same with 0.50mm thick binding wire.
Distribution System
Supply of following sizes (pipes for rising main/distribution system conforming to latest/relevant I.S. 8329/2000 Specifications conforming to latest /relevant I.S. specifications, suitable for D.I pipes and I.S. 4984/2016 Specifications conforming to latest /relevant I.S. specifications, suitable for HDPE pipes including F.O.R. destination and all taxes and insurance etc. with loading, unloading but excluding the cost of trenches).all complete as per instructions of Engineer -in - charge.
110 mm dia HDPE PN-6 PE-100
140 mm dia HDPE PN-6 PE-100
160 mm dia HDPE PN-6 PE-100
200 mm dia DI K-7
250 mm dia DI K-7
300 mm dia DI K-7
350 mm dia DI K-7
400 mm dia DI K-7
450 mm dia DI K-7
500 mm dia DI K-7
600 mm dia DI K-7
Supply of the following sizes of C.I. Double flanged sluice valves and tail peace as per I.S. 780/1969 class-1 working pressure 10kg/sqcm F.O.R destination
Supply of 80 mm dia C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including lowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with including values and specials, testing etc. complete
Supply of 50 mm dia screwed down type air valve with gun metal seat at site stone including lowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with including values and specials Required, testing etc. complete
Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia duck foot band and 63 mm dia standard make iron coupling with cap and chain etc. complete to ISS 909 at site including lowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with including values and specials, testing etc. complete.
Excavation of earth in ordinary soil (loam, clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 m and refilling watering, ramming of the excavated earth into the trench and also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour, T&P etc complete as per instructions of Engineer -in -charge.
Carting from (up to 8 Km) the following sizes of ISI marked DI pipes and specials to the site of working lowering them into trenches and laying true to alignment and gradient including testing of pipe line excluding cutting of pipes etc. for, making of lengths and making of joints.
110 mm dia HDPE PN-6 PE-100
140 mm dia HDPE PN-6 PE-100
160 mm dia HDPE PN-6 PE-100
200 mm dia DI K-7
250 mm dia DI K-7
300 mm dia DI K-7
350 mm dia DI K-7
400 mm dia DI K-7
450 mm dia DI K-7
500 mm dia DI K-7
600 mm dia DI K-7
Carting laying and jointing with fixing in proper position of the following sizes of C.I. Double flanged sluice valves and tail peace as per I.S. 780/1969 class-1 working pressure 10kg/sqcm including lowering, fixing in position and jointing then with pipe line etc comlete including all jointing material and specials of following sizes.
Provision for following types of Culvert crossing along the alignment of pipe line complete as per instructions of Engineer -in -charge. (casing of pipe is done by concreting)
Crossing of Culvert for laying pipe line including supply and materials labour, T&P etc. complete.
Crossing of Nala/drain for laying pipe line including supply and materials labour, T&P etc. complete.
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions.
200 mm dia pipe, 6mm Pipe Wall Thickness
250 mm dia pipe, 6mm Pipe Wall Thickness
300 mm dia pipe, 6mm Pipe Wall Thickness
350 mm dia pipe, 6mm Pipe Wall Thickness
400 mm dia pipe, 6mm Pipe Wall Thickness
450mm dia pipe, 8mm Pipe Wall Thickness
600mm dia pipe, 8mm Pipe Wall Thickness
Dismantling of the following type of road surface for laying of pipe line including sorting out and stacking of serviceable materials and disposal of unserviceable materias upto a distance of 50 m. as per instructions of Engineer -in -charge.
B.O.E. surface
Bituminous surface
Interlocking Road
C.C. Road
Stone Patiya
Reinstatement of the following type of road surface with old and new materials including supply of all materials labour T&P etc. required for proper completion of the work as per instructions of Engineer -in -charge.
B.O.E. surface (15 Cm. sand with first class brick 50% New and 50% Old)
Bituminous surface (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20%
Interlocking Road (existing usable Interlocking bricks M-30 grade, on 20cm local sand & 10cm TH. PCC 1:6:12). Incl. Entire surface Spreading 3 cm local sand for paste of brick & joint filling
C.C. Road in M25 grade, minimum thickness 15cm on 20cm th. sand & 15 .cm th. PCC (M15) filling base & 10 cm GSB
Stone Patiya (existing usable Stone Patia, on 20cm local sand & 10cm TH. PCC 1:6:12). Incl. Entire surface Spreading 3 cm local sand for paste of brick & joint filling
Making new House Connection with 20 mm hdpe pipe up to 5m in length in 90-600 mm dia of DI / HDPE Distribution main including Dismentling of Road, excavation of earth, supply, carting of e-fusion specials, lowering them into trenches, fixing them including bailing out water necessary excavation for connection, G.I. pipe minimum class 2 m, E-fusion clamp, water tap ferrule and all other material required heavy duty brass bib cock as per type design . Including all labour, T&P etc. required for proper completion of the works as per design and satisfaction of engineer in charge.
For 90mm to 110mm dia
For 125mm to 160mm dia
For 200mm to 250mm dia
For 300mm dia
For 350mm to 600mm dia
Shifting of house connections from old distribution main to new distribution main with 20 mm hdpe pipe up to 5m in length including supply of all material labour T&P etc in 90-600 mm dia line DI / HDPE Distribution main including Dismentling of Road, excavation of earth, supply, carting of e-fusion specials, lowering them into trenches, fixing them including bailing out water necessary excavation for connection, G.I. pipe minimum class 1m, E-fusion clamp, water tap ferrule and all other material required heavy duty brass bib cock as per type design . Including all labour, T&P etc. required for proper completion of the works as per design and satisfaction of engineer in charge.
For 90mm to 110mm dia
For 125mm to 160mm dia
For 200mm to 250mm dia
For 300mm dia
For 350mm to 600mm dia
Construction of following type chambers as per department type design and drawing including Heavy duty M.S. Manhole Cover and all materials, labour, T&P etc complete for proper completion of work as per instructions of Engineer -in -charge.
Sluice valve chamber (masonry Type) - dia above 150 mm - 1000 (L) x 1200 (W) x 1300 (H) mm as per departmental drawing
Sluice valve chamber (surface box Type) - dia upto 125 mm as per departmental drawing
Fire Hydrant chamber (750 (L) X 450 (W) X 1000 (H) mm) as per departmental drawing
Air Valve Chamber 350 (L) x 350 (W) x 500 (H) mm as per departmental drawing
Scour Valve Chamber dia upto 200 mm - 1000 (L) x 1200 (W) x 1300 (H) mm as per departmental drawing
Design and construct Thrust Block made in R.C.C. with cement coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 for pipe line including supply of MS reinforcement wrought to required shape as necessary its bending fixing & binding the same with 0.50 mm thick binding wire in position & necessary centering & shuttering including curing and supply of all materials labour T & P etc. required for proper completion of the work and as per specifications for RCC work as per instructions of Engineer -in -charg
Supply of MS reinforcement wrought to required shape as necessary its bending, fixing & binding the same with 0.50mm thick binding wire.
Construction of H.T. Panel and L.T. Panel Room in the RCC framed structure including all the associated works
H.T. Panel Room
L.T. Panel Room
Construction of Booster Pump house room sizes 6m x5m in the RCC framed structure including all the associated works
Construction of Boundary Wall, Gate and Approach road as per type design of upjn
Construction of 1.80 m high and 115mm thick boundary wall with 230 mmx230 mm thick pillar made in Brick masonry in 1 cement and 4 sand mortar, the spacing between two pillar should not be more than 3.0 m c/c and the depth of foundation should not be less than 0.60m, at the site of water works as per departmental type design and drawing, and, as per specifications given in the bid document including supply of all materials, labour T&P etc.for proper completion of work as per instructions of Engineer -in -charge.
Repairing of boundry wall as per departmental type design at water works including supply of all materials, labour T&P etc. complition of work.
Supply and fixing of 3.6 m x 1.20 m MS gate along with Fixing 1.2 m for water work including fabrication and supply of steel and construction of bounary wall pillars of size 1.35mx0.23mx0.23m with ornamental brick work 115mm th. around RCC, as per departmental type design and drawing (Drawing No. D-1) and as per specifications laid down in the bid document, including supply of all material, labour,T&P etc.required for proper completion of work as per instructions of Engineer-in-charge.
Construction of Coloured Interlocking road with for approach kerb stones on side for water works, as per departmental type design and drawing and as per specifications laid down in the bid document, including supply of all materials , labour, T&P etc.required for proper completion of work as per instructions of Engineer -in -charge.
Earth filling work for proper leveling of water work site, in accordance with the contour map and Grid map of existing site enclosed, including leveling, dressing, excavation and filling of earth where necessary and also including all labour, materials, T&P etc.required for proper completion of works and also including carriage of earth from within a distance of about 8 km. from the site of works as per instructions of Engineer -in -charge.
Supply of all material labour T&P etc required for Construction of Cemicurcular 250 mm dia drain along boundry wall as per instructions of Engineer -in -charge.
Provision for arboroculture of water works compound including green grass, show tree etc.
Provide of all material labour, T&P etc and Construt of two room staff quarter/ office room at water works site identified by the Engineer -in-charge as per department type design and rawing and specifications of civil work laid down in the bid document, including all material, labour, T&P etc complete for proper completion of work as per instruction of Engineer-in-charge
Provide all materials labour and T&P etc required for proper completion of Construction of ground water recharge mechanism
E/M Work
CLEAR WATER PUMPING PLANT
2500 LPM discharge 30 m head (1W+1S) ( Zone-1)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 2500 LPM discharge 30 m head complete with column Pipe of size 200mm, Suitable length , for (1W+1S+1 Spare) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. as per tender document specification and direction of EIC
Main Piping accessories & Valves with Actuator
Delivery Pipe Size of 200mm and Common Header of 200 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 200 mm dia Reflux Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side 01 For cwr inlet as per tender documents
Kirloskar/IVC make 200 mm dia Reflux Valve confirming to IS - 5312 part -1)
SITC of Actuator Panel
SITC of UPS of suitable capacity (3 KVA) for operation actuators installed at outlet line, in case of power failure at the time of distribution water supply with cabinet
Tee of size 200x200 mm dia.
M.S.distance piece of 200 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 200 mm Diameter
200 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3140 LPM discharge 44 m head (2 W+1 S) ( Zone-2)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3140 LPM discharge 44 m head complete with column Pipe of size 200mm, Suitable length , (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 200mm and Common Header of 300 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 200 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 300 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make sluice Valve 350mm dia with actuator having specification confirming (as per IS 14446-2000) for cwr inlet
Kirloskar/IVC make 300 mm dia Reflex Valve confirming to IS - 5312 part -1)
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at inlet line, in case of power failure at the time of distribution water supply with cabinet
SITC of Actuator Panel
Tee of size 200x300 mm dia.
M.S.distance piece of 200 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 300 mm Diameter
300 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
chequer plate of 8 mm thickness,as per site requirement
Rubber resistance sheet.
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
2814 LPM discharge 44 m head (2 W+1 S) ( Zone-3)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 2814 LPM discharge 44 m head complete with column Pipe of size 200mm, Suitable length , (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 200mm and Common Header of 300 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 200 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 300 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make sluice Valve 350mm dia with actuator having specification confirming (as per IS 14446-2000) for cwr inlet
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at inlet line, in case of power failure at the time of distribution water supply with cabinet
Kirloskar/IVC make 300 mm dia Reflex Valve confirming to IS - 5312 part -1)
SITC of Actuator Panel
Tee of size 200x300 mm dia.
M.S.distance piece of 200 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 300 mm Diameter
300 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3140 LPM discharge 44 m head (1 W+1 S+1 spare) ( Zone-4)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3140 LPM discharge 44 m head complete with column Pipe of size 200mm, Suitable length , (1W+1S+1 spare) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 200mm and Common Header of 200 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 14446-2000)
Kirloskar/IVC make 200 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make 200 mm dia Reflex Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side 01 For cwr inlet
SITC of Actuator Panel
SITC of UPS of suitable capacity (3 KVA) for operation actuators installed at inlet line, in case of power failure at the time of distribution water supply with cabinet
Tee of size 200x200 mm dia.
M.S.distance piece of 200 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 200 mm Diameter
200 mm dia C.I/D.I. dismantling joint PN 1.6
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3816 LPM discharge 44 m head (2 W+1 S) ( Zone-5)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3816 LPM discharge 44 m head complete with column Pipe of size 250mm, Suitable length , (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 250mm and Common Header of 350 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 250 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 250 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 350 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make 350 mm dia Reflex Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 350mm dia with actuator having specification confirming (as per IS 14446-2000) for cwr inlet
SITC of Actuator Panel
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at inlet line, in case of power failure at the time of distribution water supply with cabinet
Tee of size 250x350 mm dia.
M.S.distance piece of 250 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 350 mm Diameter
350 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3300 LPM discharge 44 m head (2W+1 S) ( Zone- 6)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3300 LPM discharge 44 m head complete with column Pipe of size 200mm, Suitable length , for (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. as per tender document specification and direction of EIC
Main Piping accessories & Valves with Actuator
Delivery Size of 200mm and Common Header of 300 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 200 mm dia Reflux Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 300mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make 300 mm dia Reflux Valve confirming to IS - 5312 part -1)
SITC of Actuator Panel
Tee of size 200x300 mm dia.
M.S.distance piece of 200 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 300 mm Diameter
300 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete set & piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3942 LPM discharge 44 m head (2 W+1 S) ( Zone-7)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3942 LPM discharge 44 m head complete with column Pipe of size 250mm, Suitable length , (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 250mm and Common Header of 350 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 250 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 250 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 350 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make 350 mm dia Reflex Valve confirming to IS - 5312 part -1)
SITC of Actuator Panel
Tee of size 250x350 mm dia.
M.S.distance piece of 250 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 350 mm Diameter
300 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3442 LPM discharge 44m head (1 W+1 S+1 S.S) ( Zone-8)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3442 LPM discharge 44m head complete with column Pipe of size 250mm, Suitable length , (1W+1S+1S.S) pumping plant
Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 200mm and Common Header of 200 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 200 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 200 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 250 mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make 250 mm dia Reflex Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 250mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side 01 For cwr inlet
SITC of Actuator Panel
SITC of UPS of suitable capacity (3 KVA) for operation actuators installed at inlet line, in case of power failure at the time of distribution water supply with cabinet
Tee of size 200x250 mm dia.
M.S.distance piece of 200 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 250 mm Diameter
250 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
3940 LPM discharge 44 m head (2 W+1 S) ( Zone-9)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3940 LPM discharge 44 m head complete with column Pipe of size 250mm, Suitable length , (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 250mm and Common Header of 350 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 250 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 250 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 350mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make sluice Valve 500mm dia with actuator having specification confirming (as per IS 14446-2000) for cwr inlet
SITC of Actuator Panel
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at inlet line, in case of power failure at the time of distribution water supply with cabinet
Kirloskar/IVC make350 mm dia Reflex Valve confirming to IS - 5312 part -1)
Tee of size 250x350 mm dia.
M.S.distance piece of 350 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Fourway motion ,double girder Gantry Crane Having 10 Metre lift, suitable span as per CWR sizeChain pulley Block all electrically operated complee in all respect as per tender specification.
Electromagnetic Flowmeter 350 mm Diameter
350 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
60HP (2 W+1 S) ( Zone-10)
Supply of VT Clear water pump (as per civil structure) and appurtenant / related accessories ,etc complete. to lift 3785 LPM discharge 44 m head complete with column Pipe of size 250mm, Suitable length , (2W+1S) pumping plant,Flange Mounted Solid Shaft Motor, 1475/985 RPM(preferable 985 rpm) , LT Type of motor with arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.
Main Piping accessories & Valves with Actuator
Delivery Size of 250mm and Common Header of 350 mm size (approx wt in Kg)
Kirloskar/IVC make sluice Valve 250 mm dia with actuator having specification confirming (as per IS 1446-2000)
Kirloskar/IVC make 250 mm dia Reflax Valve confirming to IS - 5312 part -1)
Kirloskar/IVC make sluice Valve 350mm dia with actuator having specification confirming (as per IS 14446-2000) for common header and bypass side
Kirloskar/IVC make350 mm dia Reflex Valve confirming to IS - 5312 part -1)
SITC of Actuator Panel
Tee of size 250x350 mm dia.
M.S.distance piece of 250 mm dia 1.0 M. long (as per requirement)
M.S. Enlarger/Reducer of suitable size as per site requirement.
Supply of 3 Ton Capacity Gantry Crane Having 10 Metre lift, suitable span as per CWR size with girder & Mono Rail Trolley, Chain pulley Block all electrically operated.
Electromagnetic Flowmeter 350 mm Diameter
350 mm dia C.I/D.I. dismantling joint PN 1.6
2 HP Dewatering Pump with complete piping
Internal Electrification and Campus Lighting
SITC of 2 KW Solar Power Plant with battery backup for Internal & external Lighting complete in all respect as per tender document.
Power Wiring & Earthing material.
Rubber resistance sheet.
chequer plate of 8 mm thickness,as per site requirement
Erection of Pumping plant including necessary Nut bolts,packing & supporting block for valves etc
Commissioning & Testing at site & works of pumping plant
Booster pumping plant for zone-1
supply of 69 LPS,6 mtr head booster pump set (1W+1S),with suction strainer,single stage with 4 Pole,10 kw LT moter IP68 protected,2900 rpm,VFD operated moter with VFD control panel of Suitable capacity for Above motor pump-set complete in all respect
SITC, lowering, laying, aligning, fixing in position jointing in pipeline of 300 mm dia/suitable size D/F DI solenoid operated diaphragm type (Flow Control Valve) PN 1.6 class valve,for Main Line and inlet/outlet line of 2 nos pump sets. suitable for SCADA compatibility complete including all material, labour, testing and commissioning as per EIC
main piping,reducer /enlarger, tee ,bend and all other accessories for fitting of pumping plant and related items complete
pressure transmitter
integration of booster pp and panel with scada panel and software ,proggramming work etc to run pp in auto mode
sitc of main switch,complete cabling work including 3 phase power supply from pump house to booster pumping plant
Booster pumping plant for zone-4
supply of 64 LPS,6 mtr head booster pump set (1W+1S),with suction strainer,single stage with 4 Pole,10 kw LT moter IP68 protected,2900 rpm,VFD operated moter with VFD control panel of Suitable capacity for Above motor pump-set complete in all respect
Providing, lowering, laying, aligning, fixing in position jointing in pipeline of 350 mm dia/suitable size D/F DI solenoid operated diaphragm type (Flow Control Valve) PN 1.6 class valve, suitable for SCADA compatibility complete including all material, labour, testing and commissioning as per EIC
main piping,reducer /enlarger, tee ,bend and all other accessories for fitting of pumping plant and related items complete
pressure transmitter
integration of booster pp and panel with scada panel and software ,proggramming work etc to run pp in auto mode
sitc of main switch,complete cabling work including 3 phase power supply from pump house to booster pumping planr
400 mm dia OHT outlet AT ZONE-1&8
SITC OF CE/UL certifeid Radar Type level sensor with transmitter for OHT
SITC OF sluice valve with Actuator of 400 mm dia size for OHT ,throtlled at any position at any instant, inbuilt with positioning card and panel
SITC of CE/UL certifeid Electromagnetic Flowmeters for OHT.size delivery pipe dia 400 mm
400 mm dia C.I. dismantling joint PN 1.0
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at outlet line, in case of power failure at the time of distribution water supply with cabinet
Complete wiring, cabling, earthing & arrangement of power and communication with PLC if power and PLC is not nearby and arrangement of protection for these intruments/equipments- complete in all respect
For 500 mm dia OHT outlet AT ZONE-2,3,4,5&10
SITC OF CE/UL certifeid Radar Type level sensor with transmitter for OHT
SITC OF sluice valve with Actuator of 500 mm dia size for OHT ,throtlled at any position at any instant, inbuilt with positioning card and panel
SITC of CE/UL certifeid Electromagnetic Flowmeters for OHT.size 500 mm
500 mm dia C.I. dismantling joint PN 1.0
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at outlet line, in case of power failure at the time of distribution water supply with cabinet
Complete wiring, cabling, earthing & arrangement of power and communication with PLC if power and PLC is not nearby and arrangement of protection for these intruments/equipments- complete in all respect
For 600 mm dia OHT outlet AT ZONE-6,7,&9
SITC OF CE/UL certifeid Radar Type level sensor with transmitter for OHT
SITC OF sluice valve with Actuator of 600 mm dia size for OHT ,throtlled at any position at any instant, inbuilt with positioning card and panel
SITC of CE/UL certifeid Electromagnetic Flowmeters for OHT.size 600 mm
600 mm dia C.I. dismantling joint PN 1.0
SITC of UPS of suitable capacity (5 KVA) for operation actuators installed at outlet line, in case of power failure at the time of distribution water supply with cabinet
Complete wiring, cabling, earthing & arrangement of power and communication with PLC if power and PLC is not nearby and arrangement of protection for these intruments/equipments- complete in all respect
ELECTRIC SUB STATION (Note-For cable work in all zone,shall be paid as per actual consumption)
L.T. Pannel for zone-1 CWR
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-MCC panel having 1 Nos. incoming having 100 amp 4P ,microprocessor based MCCB & outgoing Panels (2 No.) 63 amp MCCB, 03 Nos 32 Amp MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays apru and other Protective Devices Complete in all Respects. Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel of 32 kvar capacity/ suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
30 HP soft Starter Panel
Three phase 63 kva,11kv/0.4kw transformer with double pole sub- station
Supplying and laying of Power cable of 25 sq. mm size of 440 Volt grade 3.5core armoured XLPE sheathed Al conductor for transformer to meter & LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 10 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
ELECTRIC SUB STATION
L.T. Pannel for zone-2 CWR
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-L.T. panel having 2 Nos. incoming from Transformer having 400 amp 4P ,microprocessor based MCCB & 1 No outgoing. MCC panel having outgoing Panels (3 No.) 100 amp MCCB, 02 Nos 63 Amp & 2 No 32 Amp MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,APRU,Surge protector ,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects. Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel with 75 KVAR/ suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
HT Panel Providing with11 kV system 630 Amp 25 Ka VacuumCircuit Breaker panel Indoor type having 1 incomer & 02 outcomer incuding CT of required ratio for,metering and protection,including 3O/C and E/F relay,and high speed trip relay.
50 HP soft Starter Panel
160 KVA 11/0.440 kv LT copper wound Transformer with all accessories like buchholz relay marshalling box, and other relay continuously rated,for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45o C by, thermometer in oil and 50oC by the,resistance in winding after,continuous run resistance in,winding after continuous run at full load rating, EE Level - III provided specification as per is1180 (Part I) : 2014)
Supplying and laying of Power cable of 70 sq mm/suitable size of 11000 Volt grade 3.0 core armoured XLPE sheathed Al conductor from UPPCL metering panel to HT Panel & to transformer
Supply and making end termination/joints of the above cable
Supplying and laying of Power cable of 240 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Al conductor for transformer to LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 25 sq. mm size of 440 Volt grade 3.5 core un-armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Proper fencing of sub-station portion as per IE Rules
Charges of Electrical safety clearance.
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Erection H.T./L.T. panels, transformers, laying of cables & filling H.T., L.T. Cable end boxes as detailed above.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
ELECTRIC SUB STATION
L.T. Pannel for zone-3 CWR
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-L.T. panel having 2 Nos. incoming from Transformer having 400 amp 4P ,microprocessor based MCCB & 1 No outgoing. MCC panel having outgoing Panels (3 No.) 100 amp MCCB, 02 Nos 63 Amp & 2 No 32 Amp MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects. Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel with 75 KVAR/ suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
HT Panel Providing with11 kV system 630 Amp 25 Ka VacuumCircuit Breaker panel Indoor type having 1 incomer & 02 outcomer incuding CT of required ratio for,metering and protection,including 3O/C and E/F relay,and high speed trip relay.
50 HP soft Starter Panel
160 KVA 11/0.440 kv LT copper wound Transformer with all accessories like buchholz relay marshalling box, and other relay continuously rated,for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45o C by, thermometer in oil and 50oC by the,resistance in winding after,continuous run resistance in,winding after continuous run at full load rating, EE Level - III provided specification as per is1180 (Part I) : 2014)
Supplying and laying of Power cable of 70 sq mm/suitable size of 11000 Volt grade 3.0 core armoured XLPE sheathed Al conductor from UPPCL metering panel to HT Panel & to transformer
Supply and making end termination/joints of the above cable
Supplying and laying of Power cable of 240 sq. mm size 3.5 core of 440 Volt grade armoured XLPE sheathed Al conductor for transformer to LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 25 sq. mm size of 440 Volt grade 3.5 core un-armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Proper fencing of sub-station portion as per IE Rules
Charges of Electrical safety clearance.
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Erection H.T./L.T. panels, transformers, laying of cables & filling H.T., L.T. Cable end boxes as detailed above.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
ELECTRIC SUB STATION
L.T. Pannel for zone-4 cwr
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-MCC panel having 1 Nos. incoming having 100 amp 4P ,microprocessor based MCCB & outgoing Panels (2 No.) 63 amp MCCB, 03 Nos 32 Amp MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects. Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel of 32 kvar capacity/ suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
30 HP soft Starter Panel
Three phase 63 kva,11kv/0.4kw transformer with double pole sub- station
Supplying and laying of Power cable of 25 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Al conductor for transformer to meter & LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 10 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
ELECTRIC SUB STATION
L.T. Pannel for zone-5 CWR
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-L.T. panel having 2 Nos. incoming from Transformer having 400 amp 4P ,microprocessor based MCCB & 1 No outgoing. MCC panel having outgoing Panels (3 No.) 125 amp MCCB, 02 Nos 63 Amp & 2 No 32 Amp MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects. Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel with 90 KVAR/ suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
HT Panel Providing with11 kV system 630 Amp 25 Ka VacuumCircuit Breaker panel Indoor type having 1 incomer & 02 outcomer incuding CT of required ratio for,metering and protection,including 3O/C and E/F relay,and high speed trip relay.
60 HP soft Starter Panel
200 KVA 11/0.440 kv LT copper wound Transformer with all accessories like buchholz relay marshalling box, and other relay continuously rated,for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45o C by, thermometer in oil and 50oC by the,resistance in winding after,continuous run resistance in,winding after continuous run at full load rating, EE Level - III provided specification as per is1180 (Part I) : 2014)
Supplying and laying of Power cable of 70 sq mm/suitable size of 11000 Volt grade 3.0 core armoured XLPE sheathed Al conductor from UPPCL metering panel to HT Panel & to transformer
Supply and making end termination/joints of the above cable
Supplying and laying of Power cable of 150 sq. mm X 2 R size of 440 Volt grade 3.5 core armoured XLPE sheathed Al conductor for transformer to LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 35 sq. mm size of 440 Volt grade 3.5 core un-armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Proper fencing of sub-station portion as per IE Rules
Charges of Electrical safety clearance.
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Erection H.T./L.T. panels, transformers, laying of cables & filling H.T., L.T. Cable end boxes as detailed above.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
ELECTRIC SUB STATION FOR CWR ZONE-6,7,9 & 10
zone 6,7,9,10 of L.T. Pannel
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-L.T. panel having 2 Nos. incoming from Transformer having 400 amp 4P ,microprocessor based MCCB & 1 No outgoing. ,MCC panel having 3 Nos outgoing for MCC panel 125 amp MCCB, 01 Nos 63 Amp MCCB,01 Nos 32 Amp MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects. Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel with suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
HT Panel Providing with11 kV system 630 Amp 25 Ka VacuumCircuit Breaker panel Indoor type having 1 incomer & 02 outcomer incuding CT of required ratio for,metering and protection,including 3O/C and E/F relay,and high speed trip relay.
60 HP (45kw) soft Starter Panel
200 KVA 11/0.440 kv LT copper wound Transformer with all accessories like buchholz relay marshalling box, and other relay continuously rated,for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45o C by, thermometer in oil and 50oC by the,resistance in winding after,continuous run resistance in,winding after continuous run at full load rating, EE Level - III provided specification as per is1180 (Part I) : 2014)
Supplying and laying of Power cable of 70 sq mm/suitable size of 11000 Volt grade 3.0 core armoured XLPE sheathed Al conductor from UPPCL metering panel to HT Panel & to transformer
Supply and making end termination/joints of the above cable
Supplying and laying of Power cable of 2Rx120 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Al conductor for HT panel to LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 25 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Proper fencing of sub-station portion as per IE Rules
Charges of Electrical safety clearance.
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Erection H.T./L.T. panels, transformers, laying of cables & filling H.T., L.T. Cable end boxes as detailed above.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
ELECTRIC SUB STATION
L.T. Pannel for zone-8cwr
2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items-L.T. panel having 2 Nos. incoming from Transformer having 400 amp 4P ,microprocessor based MCCB & 1 No outgoing. MCC panel having outgoing Panels (2 No.) 100 amp microprocessor based MCCB, 01 Nos 63 Amp MCCB ,01 Nos 32 Amp MCCB for aux light & suitable to operated on 400 ± 5 % volt , 3 Phase , 50 Hz, AC supply ,with HMI, C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects.Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU.
APFC panel with suitable capacity of capacitor bank having suitable MCCB and Discharge system with all necessary relays,instruments & wiring etc. Complete.
HT Panel Providing with11 kV system 630 Amp 25 Ka VacuumCircuit Breaker panel Indoor type having 1 incomer & 02 outcomer incuding CT of required ratio for,metering and protection,including 3O/C and E/F relay,and high speed trip relay.
for (60 HP) 45kw soft Starter Panel
100 KVA 11/0.440 kv LT copper wound Transformer with all accessories like buchholz relay marshalling box, and other relay continuously rated,for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45o C by, thermometer in oil and 50oC by the,resistance in winding after,continuous run resistance in,winding after continuous run at full load rating, EE Level - III provided specification as per is1180 (Part I) : 2014)
Supplying and laying of Power cable of 70 sq mm/suitable size of 11000 Volt grade 3.0 core armoured XLPE sheathed Al conductor from UPPCL metering panel to HT Panel & panel to transformer
Supply and making end termination/joints of the above cable
Supplying and laying of Power cable of 120 sq. mm size of 440 Volt grade 3.50 core armoured XLPE sheathed Al conductor Transormer to LT panel
Supply and making end termination of the above cable
Supplying and laying of Power cable of 25 sq. mm size of 440 Volt grade 3.5 core armoured XLPE sheathed Cu conductor from LT Panel to Motor JB.
Earthing of electrical equipments as per IS/ IER
Proper fencing of sub-station portion as per IE Rules
Charges of Electrical safety clearance.
Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.
12/20 mm. thick rubber electric resistance rubber sheet as per ISS.
Erection H.T./L.T. panels, transformers, laying of cables & filling H.T., L.T. Cable end boxes as detailed above.
Exhaust fans of suitable sweep/capacity
MS. chaquer plates for covering of trenches
Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary.
FOR SCADA WORK IN ALL CWR (ZONE-1 to ZONE-10)
CE/UL certified local conrol room PLC/RTU with redundant CPU& power supply in IP 54 enclouser to communiate with gsm based modem unit with redundant cpu & power supply with analog and digital parameter and features as per spec mentioned in technical bid documents.
GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & receive data & gather data form remote sites to control station,All accessories include signal enhancer antenna along with running expences till DLP.
Intelligent energy meter
Smart Pressure transmitter
Auto phase reversal unit/Automatic transfer switch with inbuilt time delay and enclosure (Conforming to IEC 60947-1 & IEC 60947-6-1) of suitable for suitable size (200 amp). rating
Cabling for ZPS including all power & control cables
Security survelliance IP camera
Radar type level transmitter with RTU communication
Surge protector for all AC control supplies to all the equipment
7" HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters
SITC of Cl analyzer at CWR
Installation, testing and commissioning
double Earthing work of all equipments of scada system
LCS & INTEGRATION WITH EXISTING MCS
CE/UL certified local conrol room PLC with redundant CPU& power supply at LCS in IP 54 enclouser as per spec mentioned in technical bid documents,including integration with existing MCS
Full development version of required TAGS SCADA Software with coustomization of software for LCS as per spec mentioned in technical bid documents.
CE / UL Certified industrial grade 65" LED MONITOR with latest configuration as per technical specification.
Internet connection with Static IP
CE & BIS approved H.P or equvalent computer with latest configuration i- 7 processor, 1TB - HDD , 8 GB RAM , DVD , Minimum 32" LED LG/Samsung or equivalent , mouse & key board, UPS & other Required item as per technical bid documents
CE/UL Certified 3 KVA UPS with batteries as per spec mentioned in tachnical bid documents.
GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & receive data & gather data form remote sites to control station,All accessories include signal enhancer antenna along with running expences till DLP.
Mobile App facility system architecture ( Industria internet based & viewed through mobile apps for increased local & remote visibility)
CE/UL certified Firewall for network protection.
Surge protector for Ethernet communication protection.
Industrial grade Ethernet Switch.
Canon/hp Laser printer1018 or equivalent(1 Color & 1 B&W)
Installation,Commissioning ,testing including required furniture as 2 moduler Tables, 10 Chair, Control Desk & other necessary Furniture items for LCS room internal wiring,PVC panelling of walls/false ceiling work etc.
Model of Water Supply Scheme for Presentation with table top
SITC of 2 KW Solar Power Plant for Internal & external Lighting at campus with battery backup.
Split AC suitable for the control room 1.5 tonnes 5 star
Security Survelliance IP Camera with required hard drive to store data of atleast 15 Days
Three Month Trial & Run
Three Month Trial & Run for all zones PP
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_2090640.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.32 MB
Tender_Document_Cluster4WSS.pdf
Tender Documents • 22.70 MB
BOQ_2090640.xls
BOQ • 1.11 MB
Download all tender documents and submit your bid