Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L-1 | Accepted-AOC Accepted being L1 |
| 2 | L-2₹3.8 Cr+₹24.3 L (6.91%)Rejected-Finance H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | ₹3.8 Cr+₹24.3 L (6.91%) | L-2 | Rejected-Finance Not being L-1 |
| 3 | S Balbir Singh L-3₹4.0 Cr+₹50.2 L (14.3%)Rejected-Finance | ₹4.0 Cr+₹50.2 L (14.3%) | L-3 | Rejected-Finance Not being L-1 |
| 4 | L-4₹5.4 Cr+₹1.8 Cr (52.5%)Rejected-Finance | ₹5.4 Cr+₹1.8 Cr (52.5%) | L-4 | Rejected-Finance Not being L-1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical See evaluation |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
17 Mar 2020, 6:00 pmClosed
CE AF BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
801323A/E8 EXT SERVICES TO STP AT AFS BEGUMPET
2020_MES_323225_1
120_801323A/E8
Open Tender
Civil Works
Lump-sum
270 days
BEGUMPET
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹2,000
Yes
₹4.3 L
Yes
22 May 2020
8 Feb 2020
18 Mar 2020
9 Feb 2020
17 Mar 2020
5 Mar 2020
9 Feb 2020 - 15 Feb 2020
Amount
BOQ UPLOADED ON 28 FEB 2020 AND BOQ UPLOADED ON 08 FEB 2020 CANCELLED
NOTE: Schedule ‘A’ Part I to IX are under Ser No. 3.00 to 11.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building or Structures” as listed in Schedule ‘A’ Part–I.
Lumpsum price worked out by the contractor for “Site Clearance and land development” as listed in Schedule ‘A’ Part–II.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–III.
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–IV.
Lumpsum price worked out by the contractor for "Sewage Disposal” as listed in Schedule ‘A’ Part–V.
Lumpsum price worked out by the contractor for "Area Drainage” as listed in Schedule ‘A’ Part–VI.
Lumpsum price worked out by the contractor for "Fencing” as listed in Schedule ‘A’ Part–VII.
Lumpsum price worked out by the contractor for "Road, Path & Culvert” as listed in Schedule ‘A’ Part–VIII.
Lumpsum price worked out by the contractor for “External Electrification” as listed in Schedule ‘A’ Part–IX.
SCHEDULE `A' PART - X (Fittings, fixtures and Miscellaneous items under Phase-I) Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Health faucet, chrome finished,suitable for 15mm bore of pipe with HDPE pipe length 900mm, wall hook, water shower gun, washers, connections, brass union etc., complete all as specified and as directed.
Point wiring complete with 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC conduit with all conduit accessories not less than 25mm dia (concealed) and including provision of 2.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, metal flush box and white cover plate with frame for suitable number of modules mounted and concealed in walls with suitable screws for housing one 3 pin socket outlet 15 Amps, on independent board complete all as specified and as directed.
(a) Chasing of walls for concealing pipes and cost of flush box and cover plate combination is deemed to be included in the rates for point wiring.
(b) Metal flush box and white cover plate with frame for suitable number of modules shall be measured and paid separately.
Metal flush box in any number of combinations as required complete all as specified and as directed.
Note:- The rate shall be quoted on per module basis irrespective of the number of modules in the combination.
White cover plate with frame in any number of combinations as required complete all as specified and as directed.
Note:- The rate shall be quoted on per module basis irrespective of the number of modules in the combination.
Modular socket, multi purpose, 2 / 3 pin, 6 Amps, complete all as specified and as directed.
Modular socket, multi purpose, 2-in-1, 3 pin, 6 / 16 Amps complete all as specified and as directed.
TV / Sat / FM, 6 shielded socket, 2 module all as specified and as directed.
Note:- Make shall be of Legrand Cat No.6730 51 or equivalent of makes as listed here-in-after.
Ceiling fan, 1200mm sweep, 230 Volts, 50 Hz A/C, 5 star and connecting including provision of two way PVC connectors, 0.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed.
Note:- Make shall be of Havells ES 50 (5 star rated) or equivalent of makes as listed here-in-after.
Wall mounting fan, 400mm sweep, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 0.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed.
Note:- Make shall be of Havells Swing Platina or equivalent of makes as listed here-in-after.
Ventilating fan, 200mm sweep, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed.
Note:- Make shall be of Havells Ventil Air DX or equivalent of makes as listed here-in-after.
Exhaust fan, heavy duty, 300mm sweep, 1400 RPM, with louvers, conforming to IS-2312-1967, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed.
Note:- Make shall be of Havells Turbo Force SP or equivalent of makes as listed here-in-after.
LED Batten luminaire with and including 20/22 W LED, extruded aluminium housing IP-20, high efficiency, surface and wall mounted, 4 feet, system wattage of 22 Watts, meets LED IS specifications, Class-1, SDCM<5, short circuit and over circuit protection, temperature range 0 to 50 degree centigrade and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed.
(a) Make shall be makes and/ Cat No./Product No. as listed below:-
(i) Bajaj Product No. 830254
(ii) Crompton Greaves Cat No. LT5RT-18-CDL.
(iii) Philips Cat No. BN021C LED 20S PSU CDL GR.
(b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.189(R)
Surface mounted LED down lights, system wattage of 09 / 10 Watts, meets LED IS specifications, Class-1, SDCM<5, short circuit and over circuit protection, temperature range 0 to 50 degree centigrade, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters complete all as specified and as directed.
(a) Make shall be makes and/ Cat No./Product No. as listed below:-
(i) Bajaj Product No. 830203
(ii) Crompton Greaves Cat No. LCTL-9-CDL.
(iii) Philips Cat No. BN021 LED 10S 6500 PSU GRS1.
(b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.189(R)
LED street light fitting 20 / 25 W, high efficient and has peanut lens optics specially designed for street lighting polycarbonate cover and an electronic driver of efficiency >85% compliant to IEC safety standards, including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Housing: Pressure die cast LM6 aluminium housing,
(b) Lumen output :2000 Lumens
(c) System efficiency: At luminaire level of >100 lumens per watt
(d) Life class : 50000 burning hours at L70
(e) Colour temperature : Around 5700
(f) Colour rendering : index of : >70
(h) Voltage variation range of 140 to 270 Volts
(j) Power factor > 0.95
(l) Surge protection of 3KV in CM
(a) Make shall be makes and/ Cat No./Product No. as listed below:-
(i) Wipro Cat No. LR02-291-XXX-57-XX
(ii) Havells Cat No. ENDURAPEARLSL20WLED757SASYTOPC.
(iii) Philips Cat No. BRP022 LED 20 CW MR S1 PSU GR.
(b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.189(R)
Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor FRLS cable, four runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor FRLS cable as earth continuity conductor concealed in wall / roof and connecting to common earth dolly complete all as specified and as directed.
(a) Four runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length.
(b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor FRLS cable, two runs of single core 4 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor FRLS cable as earth continuity conductor concealed in wall / roof and connecting to common earth dolly complete all as specified and as directed.
(a) Two runs of 4 sqmm cable and one run of 4 sqmm cable and one run of conduit will be measured as one length.
(b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor FRLS cable, two runs of single core 2.50 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 2.50 sqmm PVC insulated single core multistranded copper conductor FRLS cable as earth continuity conductor concealed in wall / roof and connecting to common earth dolly complete all as specified and as directed.
(a) Two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable and one run of conduit will be measured as one length.
(b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
MCB DB TPN 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 43 protected, with provision for FP MCB / lsolator / RCCB / RCBO as incomer and SP / TP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
Note:- Make shall be of Legrand Cat No. 6077 50 or equivalent of makes as listed here-in-after.
MCB DB SPN 4 way, acrylic, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB / RCBO double pole as incomer and DP / SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
Note:- Make shall be of Legrand Cat No. 6077 20 or equivalent of makes as listed here-in-after.
MCB 6-32 Amps, SP, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed.
Note:- Make shall be of Legrand Cat No.4085 87 - 4085 95, Schneider Electric Cat No.A9N1P06C-32C or equivalent of makes as listed here-in-after.
MCB 6-32 Amps, SPN, 240 Volts, 50 Hz, AC supply, "C" curve with breaking capacity of 10 kA complete all as specified and as directed.
Note:- Make shall be of Legrand Cat No.4086 09 - 4086 17 or equivalent of makes as listed here-in-after.
Digital type daily and weekly timer switch with quick and easy programming, switch times visible in weekly overview on display including necessary fixing arrangements all as specified and as directed.
Note:- Make shall be of Legrand Cat No.4126 31 or equivalent of makes as listed here-in-after.
SMC (Sheet Moulded Compound) junction box, outdoor type of minimum size 140mm x 140mm x 95mm, loop in - loop out cable connections including necessary clamps made out of mild steel flat iron, nuts, bolts etc for fixing to steel tubular poles including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Note:- Make shall be Sintex Cat No. GSJB-1414 or equivalent of makes as listed here-in-after.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 32mm x 6mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Pre-cast cement concrete block masonry with grade 'C' solid blocks exceeding 10cm in width having minimum compressive strength of 50 Kg/Sqcm as per IS 2185 (Part-I) 2005 and set in CM 1:4 complete all as specified and as directed.
_BLANK_
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia 250mm complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia 200mm complete all as specified and as directed.
Supply, installation, testing and commissioning of non-clog vertical submersible pump coupled with electric motor 415 Volt, AC, 3 Phase, 50 Hz, of capacity 10 HP, with a miximum of 700 LPM at a maximum of 40m head, with chrome steel impeller, cutter for smooth suction to pass around 40mm size particles, including supply and installation of automatic star delta starter of 10 HP, 3 phase capacity all as per recommendation of non-clog pump manufacturer, guide rail alongwith chain pulleys, supporting ropes, delivery hose of PVC material and 80mm size and length 50m, submersible flat copper cable 4 core, 6 sqmm, 30m length including suitable earthing complete all as specified and directed.
Supply, installation, testing and commissioning of non-clog vertical submersible pump coupled with electric motor 415 Volt, AC, 3 Phase, 50 Hz, of capacity 20 HP, with a miximum of 1500 LPM at a maximum of 40m head, with chrome steel impeller, cutter for smooth suction to pass around 40mm size particles, including supply and installation of automatic star delta starter of 20 HP, 3 phase capacity all as per recommendation of non-clog pump manufacturer, guide rail alongwith chain pulleys, supporting ropes, delivery hose of PVC material and 100mm size and length 60m, submersible flat copper cable 4 core, 10 sqmm, 60m length including suitable earthing complete all as specified and directed.
Cutting across roads / hardstanding to a depth of 600mm for taking up / laying LT under ground cable and returning, filling in the excavated earth in any type of soil, well ramming, making good the top portion to a thickness of 75mm with plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate and finished fair and even complete all as specified and as directed.
Note:- Measurement shall be area as measured on plan.
Air release valve (double action), heavy duty with bolts and nuts, natural rubber moulded on wooden ball, fixed up on CI water mains of bore of pipe 200mm complete all as specified and as directed
Supply, install, testing and commissioning of automatic on mains failure (AMF) silent type Diesel Engine Generating Set , air cooled, 415 Volts, 40 kVA, 3 Phase, 4 wire, 0.80 power factor, 50 Hz, 1500 RPM self excited, self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition of Hakimpet / Begumpet and conforming to condition under IS 4722, 10001 , 10002, 13364, BS 5514, 2613, 5000 and shall include alternator, diesel engine, AMF panel, relay panel and civil works complete complete all as specified and as directed.
Note:- For full details of description of items and specifications please refer under PS Clause 44 on Sl Page No.190(R), 191 to 193. Bidders are advised to read the description alongwith particular specifications before inserting their rates.
Sand filling with M-sand as screed bed under interlocking tiles including watering and consolidation complete all as specified and as directed.
_BLANK_
Cutting across roads / hardstanding to a depth of 150mm for taking up / laying LT under ground cable and returning, filling in the excavated earth in any type of soil, well ramming, making good the top portion to a thickness of 75mm with plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate and finished fair and even complete all as specified and as directed.
Note:- Measurement shall be area as measured on plan.
Decorative post top street light luminaire 42/35 W LED, with sheet aluminium circular canopy and clear acrylic cover mounted on necessary GI tubing medium grade 32mm bore of pipe length 0.50m with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surfaces complete all as specified and as directed.
(a) Make shall be makes and/ Cat No./Product No. as listed below:-
(i) Wipro Cat No. LP02-501-XXX-57-XX
(ii) Havells Cat No. CORALPT35WLED757PSYMTOPC.
(iii) Crompton Greaves Cat No. LPTOI-45-CDL.
(b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.189(R)
PVC insulated and PVC sheathed copper conductor FR cable, twin core, 2.50 sqmm, 1100 volts grade complete all as specified and as directed.
SMC (Sheet Moulded Compound) junction box, outdoor type of minimum size 250mm x 200mm x 105mm to house one number MCB SP 6-10 Amps, 10 kA, 230 Volts capacity, 100 Amps rated 4 pole connector, loop in - loop out cable connections including necessary clamps made out of mild steel flat iron, nuts, bolts etc for fixing to steel tubular poles including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
(a) Make of SMC junction box shall be Sintex Cat No. GSJB-2520 or equivalent of makes as listed here-in-after.
(b) Make of MCB shall be Legrand Cat No.4085 87 to 4085 90 or equivalent of makes as listed here-in-after.
LED street light fitting 72W, highly efficient with compliance to the following parameters and an electronic driver compliant to IEC safety standards with , , including provision of necessary GI tubing light grade 50mm bore of pipe 1.50m bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Housing: Pressure die cast LM6 aluminium housing,
(b) Lumen output :> 80 lm
(c) System efficiency: At luminaire level of >120 lumens per watt
(d) Life class : 50000 burning hours at L70
(e) Colour temperature : Around 6000 k
(f) Colour rendering : index of > 70
(h) Voltage variation range of 150 to 240 Volts
(j) Power factor > 0.90
(l) Surge protection of 3 KV
(a) Make shall be makes and/ Cat No./Product No. as listed below:-
(i) Wipro Cat No. LR02-781-XXX-57-G2.
(ii) Havells Cat No. ENDURAPEARLPLUSSL70WLED757SASYTOPC.
(iii) Philips Cat No. BRP410 LED CW 068 MR PC S1 PSU GR.
(b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.189(R)
Design, fabrication, supply, installation, testing and commissioning of factory made panel board, outdoor type, made up of CRCA sheet 3mm thick, with hinged doors, angle iron base frame (40mm x 40mm x 4mm) with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, floor mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and in accordance and connected to 3 phase distribution terminals complete all as specified and directed by Engineer-in-Charge.
(a) MCB TPN, 415 Volt, of capacity 40 Amps and rupturing capacity not less than 10 KA - 01 No.(Incoming)
Note:- Make shall be of Havells Cat No.DHMGCTNF040 or equivalent of makes as listed here-in-after.
(b) Astronomical Weekly Programmable Time Switch (SST - 1 min) - 01 No.
Note:- Make shall be of Havells Cat No.DHTBW01006 or equivalent of makes as listed here-in-after.
(c) Power contactor 32A - 1 No.
Note:- Make shall be of Legrand Cat No.4125 49 or equivalent of makes as listed here-in-after.
(d) The LT panel board shall be kept 450mm above ground level, mounted by base frame suitably embedded into platform of PCC 1:3:6, type C1, using 20mm graded stone aggregate, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of factory made feeder pillar box, KIOSK, outdoor type, made up of CRCA sheet 3mm thick, with hinged doors, front and rear openable, suitable opening for vent and cable entry, with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears, spare terminal for MCCB - 02 Nos, space for fixing submersible pump starter suitable for 20 HP capacity, including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and in accordance with IS-13947 (Part-I) 1993 & IS-8623 and all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with rating 200 Amps 3 phase and neutral with epoxy insulated coating with colour code mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB, 415 Volt, 4 pole, of capacity 100 Amps and rupturing capacity not less than 36 KA - 01 No.
(c) MCCB, 415 Volt, 3 pole, of capacity 63 Amps and rupturing capacity not less than 25 KA - 02 Nos.
(d) MCCB, 415 Volt, 3 pole, of capacity 25 Amps and rupturing capacity not less than 25 KA - 06 Nos.
(e) MCB SP, 240 Volt, "C" curve of capacity 10 Amps and rupturing capacity not less than 10 KA - 01 No.
(f) Digital display VAF panel meter - 1 No.
(g) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(h) The LT panel board shall be kept 450mm above ground level, mounted by base frame of angle iron 50mm x 50mm x 5mm, suitably embedded into platform of PCC 1:3:6, type C1, using 20mm graded stone aggregate, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of factory made feeder pillar box, KIOSK, outdoor type, made up of CRCA sheet 3mm thick, with hinged doors, front and rear openable, suitable opening for vent and cable entry, with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears, spare terminal for MCCB - 02 Nos, space for fixing submersible pump starter suitable for 20 HP Capacity including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and in accordance with IS-13947 (Part-I) 1993 & IS-8623 and all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with rating 200 Amps 3 phase and neutral with epoxy insulated coating with colour code and aluminium earth bus of size 25mm x 3mm mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB, 415 Volt, 4 pole, of capacity 63 Amps and rupturing capacity not less than 36 KA - 01 No. (Incoming)
(c) MCCB, 415 Volt, 3 pole, of capacity 25 Amps and rupturing capacity not less than 25 KA - 05 Nos. (Outgoing + 01 No. Spare)
(d) MCB SP, 240 Volt, "C" curve of capacity 10 Amps and rupturing capacity not less than 10 KA - 02 Nos.
(e) Digital display VAF panel meter - 1 No.
(f) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(g) The LT panel board shall be kept 450mm above ground level, mounted by base frame of angle iron 50mm x 50mm x 5mm, suitably embedded into platform of PCC 1:3:6, type C1, using 20mm graded stone aggregate, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Design, fabrication, supply, installation, testing and commissioning of factory made feeder pillar box, KIOSK, outdoor type, made up of CRCA sheet 3mm thick, with hinged doors, front and rear openable, suitable opening for vent and cable entry, with locking arrangement, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears, spare terminal for MCCB - 02 Nos, space for fixing submersible pump starter suitable for 5 HP / 10 HP Capacity including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and in accordance with IS-13947 (Part-I) 1993 & IS-8623 and all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with rating 200 Amps 3 phase and neutral with epoxy insulated coating with colour code and aluminium earth bus of size 25mm x 3mm mounted on suitable insulators with terminal switch - 01 Set
(b) MCCB, 415 Volt, 4 pole, of capacity 40 Amps and rupturing capacity not less than 36 KA - 01 No. (Incoming)
(c) MCCB, 415 Volt, 3 pole, of capacity 25 Amps and rupturing capacity not less than 25 KA - 05 Nos. (Outgoing + 01 No. Spare)
(d) MCB SP, 240 Volt, "C" curve of capacity 10 Amps and rupturing capacity not less than 10 KA - 02 Nos.
(e) Digital display VAF panel meter - 1 No.
(f) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.
(g) The LT panel board shall be kept 450mm above ground level, mounted by base frame of angle iron 50mm x 50mm x 5mm, suitably embedded into platform of PCC 1:3:6, type C1, using 20mm graded stone aggregate, using 20mm graded stone aggregate, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
Ductile iron pipe, for domestic sewage of 200mm diameter (8”), centrifugally cast (spun), ISI marked, spigot and socket joints of "K-9" class including jointing materials like EDPM gaskets in any length laid and tested complete all as specified and as directed.
Concrete bedding, earthwork, DI fittings etc., as required shall be measured and paid separately.
Ductile iron specials / fittings for pressure pipes for sewage i.e bends (any type,radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, "Y" junction, double branch, tail piece, cross (all socket and spigot), collars, caps and plugs upto 200mm dia as required for laying pipes complete all as specified and as directed.
Construction of valve chamber of size 1000mm x 1000mm x 1000mm (inner dimension), with 150mm thick PCC foundation 1:4:8 type D2, PCC block masonry 200mm thick built in CM 1:6, 15mm thick internal and external plaster in CM 1:4, external plaster to a depth of 150mm below ground level as also the valve chamber floor, MS sheet cover of size 1200mm x 1200mm, 3.00mm thick including flat iron framework of FI 25mm x 4mm alround the frame and diagonal bracing, base frame of angle iron 40mm x 40mm x 5mm, and 100mm thick PCC coping of 1:2:4, type B1, using 20mm graded aggregate with FI hinge, nuts, bolts, locking arrangement, handles etc, lock 7 lever of approved make with duplicate keys, and painting steel surfaces with one coat of red oxide primer and two coats of synthetic enamel black paint complete including necessary excavation in any type of strata and removal of surplus soil to a distance not exceeding 50m, complete all as specified and as directed.
Cast iron pipes with flanged ends, centrifugally cast, class "B" in any length, including rubber gasket, nuts, bolts, washers etc., to pump sewage from UG well into main header, laid and tested of bore of pipe 80mm complete all as specified and as directed.
Note:-CI specials / fittings etc., as required shall be measured and paid separately.
CI Specials / fittings i.e bends, tapers, tee pieces (single and double branch), tail pieces any type and angle / radius and straight connecting pieces, bell mouth pieces all specials with ends of flanges / spigot / socket / tapering as required, suitable for upto 200mm bore of pipe, complete all as specified and as directed
ramesh construction co
S Balbir Singh
laasya constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .