Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.8 L+₹8.4 L (27.5%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER | |
| 3 | L3₹39.4 L+₹8.9 L (29.2%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L3 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER | |
| 4 | L4₹40.0 L+₹9.5 L (31.3%)Rejected-Finance | L4 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER | |
| 5 | L5₹45.5 L+₹15.0 L (49.2%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT IS HIGHER THAN L1 BIDDER |
Tender Value
₹41.3 L
EMD Value
₹82,540
Closing Date
21 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI ARVIND KUMAR SHARMA IDSE SE CWE
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
WORKS SERVICES FOR UPGRADATION OF EXISTING POWER INFRASTRUCTURE AT AF STATION PANAGARH UNDER GE (AF) PANAGARH
2023_MES_601592_1
82396/PAN/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF PANAGARH
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE AF PANAGARH
₹82,540
Yes
8 Sept 2023
7 Jun 2023
28 Jul 2023
7 Jun 2023
21 Jul 2023
7 Jul 2023
7 Jun 2023 - 12 Jun 2023
Amount
B/R WORKS
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded aggregate as in foundation filling and mass concrete complete all as specified ans as directe.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified ans as directe.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified ans as directe.
M&L for providing 150 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in sub-base finished even and rough to receive the topping layer all as specified and as directed.
M&L for providing 100 mm thick cement concrete 1:2:4 type B-2 (using 20mm graded stone aggregate) as in path, hardstanding finished even and smooth without using extra cement all as specified and directed.
M&L for providing 50mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in path, hardstanding finished even and smooth without using extra cement all as specified and directed.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work for concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge.
Removig excavated material exc 250m & not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in ground floor as paving n exc 15 cm thickness (below of above ground level) complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directe.
M&L for brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as directed.
M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) with Fe 290 (Gde E 165) all as specified and directed.
M&L for preparation of new steel furfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M&L Plain cement concrete type B2 1:2:4 (40mm graded aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed.
M&L steel work as in hand rails, wind ties for roof including securing bolts, posts and struts in fencing including cutting top to shape as directed drilling holes, notching for wire etc flat iron fillets for securing wire mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for preparation of new steel surfaces of any description not exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only chain link mild steel galvanised fencing, any size or type complete all as specified and directed.
S&F Mild steel screw bolts (machne made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long Diameter of neck in 5 to 10 mm complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20mm graded aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20mm graded aggregate) in Columns, pillars, piers, posts and struts etc. complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter etc. complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting poing all as directed.
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick/concrete /stone surfaces, finished even and smooth without using extra cement complete all as specified and directed.
S&F for mild steel framed work as in doors or gates of angle or other section with gusset, rails, braces etc. complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and incl either books and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, runnings rails and guides) and hanging, also fastening and fixing complete all as specified and directed. (Fe410-W Gde E-250 quality-A) complete all as specified and as directed.
M&L for prewparation of new or previously untreated surfaces of wall and applying 2 coats of cement base paint over a coat of primer complete all as specified and as directed.
M&L for providing 100mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub-base finished even and rough to receive the topping layer all as specified and as directed.
Note : Prior to commencement of the subject works, the contractor needs to submit valid Electrical License in the name of himself/them self or Agreement with agency having valid Electrical License alongwith Agency's Electrical License to the Accepting Officer for his approval through GE. In absence of such documents, no work will be executed at site and to be treated as defaulter on the Contractor's part . In addition, Supervisor for execution of electrical works employed by the Contractor shall posses Supervisory Certificate of competency issued by concerned State Govt/Union Territory and the Worker/Tradesman for execution of Electrical Works must hold necessary permit issued by concerned State Govt/Union Territory.
INTERNAL ELECTRIFICATION
M&L for point wiring with 1.5 sqmm PVC sheathed and insulated copper multistranded conductor (FR) cable 1100 Volts grade (red colour cable to be used for Phase connection and black colour cable to be used for neutral connection) including PVC casing caping of suitable size with all accessories including 1.5 sqmm copper multistrand conductor FR 1100 Volts grade sheathed PVC insulated (green colour) continuity earth wire connected to common earth dolly and switch box for mounting of fittings like switch for one fan point controlled by one switch complete all as specified and as directed.
S&F ceiling rose 2 to 3 terminal single (65x50) mm surface type with PVC/ polycarbonate, isolated body, ISI marked complete all as specified and as directed.
S&F switch piano flush type 5/6 amps, 240 volt single pole one way complete all as specified and as directed.
M&L for cutting holes in brick masonry wall of size 300 mm to 600 mm dia and making good the distrubuted surfaces as original complete all as directed.
Supply & fixing Heavy Duty Single Phase IP 55 protection & ISI marked Metal exhaust fan (450mm sweep & 1400 rpm) 230V with self closing louvers complete with nuts, screws, bolts of specified sizes including electrical connection with twisted three core PVC insulated flexible cord of size 0.75 sqmm copper conductor from ceiling rose complete all as specified and as directed.
Supply & fix MCB SPN 240 volts, 10KA, 50 Hz of capacity 6-32 Amps 'C' curve all as specified.
Supply & fix MCB SP 240 volts, 10KA, 50 Hz capacity 6-32 Amps 'C' curve all as specified
Supply & fix sheet metal enclosure powder coated single phase DB, SPN, 240 Volts, 04 Way for fixing of MCBs, double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces to match with existing colour of wall complete all as specified
Material and labour for sub main wiring with approved colour coding as per IS with Two run of PVC insulated cable with stranded copper conductor of size 4 sqmm nominal area and drawing through PVC Casing caping of suitable size including one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified. Note:- (a) Two runs of 4 sqmm cable, one run of 4.0 sqmm cable and one run of non metalic conduit be measured as one unit. (b) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.
EXTERNAL ELECTRIFICATION
Supply, install, testing and commissioning of Indoor Servo controlled voltage stabilizer of capacity 150 KVA (Confirming to BIS 9815:Part1:1994) Three phase, 50 Hz, Naturally Oil cooled, indoor with IP 42 protection, unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of 400 L of transformer oil (IS335:1993 reaffirmed 2005), in voltage stabilizer up to desired level having following specification. (a) Input voltage 340V-480V, (b) Output voltage stabilized at any deigned/ desired voltage 415V ± 1% (c) Rated frequency 50 Hz (d) No distortion in wave form (e) Response time not to exceed 20 mille seconds (f) Sensitivity (± )1% (g) Rate of correction Volt/second for single phase and 13 V/seconds for phase to phase (h) Efficiency more than 95% (i) Type of load : three phase, unbalanced type (j) Digital display Voltmeter/Ammeter Protections:- 1. Over load/Short Circuit protections (MCCB with min 250A, 25KA, 3 pole, 2. High/Low voltage cut off 3. By pass arrangement in case of emergency 4. Single phase sequence change protection
Supply, Installation, Testing and commissioning of indoor type isolation transformer of capacity 160 KVA, three phase, 50Hz, Copper wound, oil cooled, class of insulation A, metallic body duly powder coated designed for input Voltage range 415± 5% and output voltage range 415± 5%, Ratio 1:1, Vector group : Dyn 11, Delta-star, indoor type with IP 42 protection (CPRI Approval Required) with first filling of transformer oil (400 Litre) of requisite dielectric strength up to level, efficiency more than 95%, separate neutral bushing shall be brought out for earthing, Potential difference between neutral to earth less than one volt with all standard fittings like digital temperature meter, adequate number of cooling radiators, lifting hooks one set, Earthing terminal two nos complete with Over load/ short circuit protection.
Taking Out existing Distribution Transformer 11KV/433V of Capacity 160 KVA, Make-Voltamp from BPI Substation transport to EE hall substation, cleaning, including Installation and testing and fixed with Existing VCB and Prop Voltage stabilizer of EE Hall Substation, Completed all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/ control board upto 7.5 m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab charcoal, watering pipe, wire mesh lugs, earth strip protection pipe 32mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2020 and all as specified. Note: Quoted rate shall be deemed to inclusive of:- (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode. (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick pre cast RCC cover with suitable handle. (e) Funnel with watering pipe with GI 20 mm nominal bore, medium grade & copper lug etc. (f) 32mm nominal bore light grade GI protection pipe 7.50 m long for protection of earthing strip. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
M & L for earthing complete with copper plate 60 x 60cm x 3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to 20x3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including excavation earth work, PCC chamber, MS sheet cover charcoal, watering pipe, wire mesh lugs, earth strip protection pipe 20mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2020 and all as specified. Note: Quoted rate shall be deemed to inclusive of:- (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode. (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 3.15mm thick MS sheet cover with 40x40x6mm thick angle iron frame. (e) Funnel with watering pipe with GI 20 mm nominal bore, medium grade & copper lug etc. (f) 32mm nominal bore light grade GI protection pipe 7.50 m long for protection of earthing strip. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion..
M&L for test point terminal block mead of gun metal of phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex. Head screw complete all as directed.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, FRLS electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, 04 core of size 120 sqmm all as directed by Engr-in-Charge.
M&L for sand cushioning/covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (Note:- Punned thickness will be measured at the time of measurement and payment)
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, Flat, size 250mm X 150mm X 40mm complete all as directed.
Supply and fixing GI pipe Light grade galvanised 100 mm dia complete with all fitting and laid on floor or wall for strip protection complete all as directed by Engineer-in-Charge.
Taking out existing Distribution Transformer of capacity - 63 KVA after disconnecting, cleaning, including deposited to MES store yard, Completed all as specified and directed by Engineer-in-Charge.
Taking out existing Voltage Stabilizer of Capacity - 63 KVA after disconnecting, cleaning, including deposited to MES store yard, Completed all as specified and directed by Engineer-in-Charge.
Taking out existing LT panel and switch gear after disconnecting, checking of Switch gear, cleaning of serviceable parts of switch gear and change over switch of existing size, including deposited to MES store yard, completed all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing and commissioning of indoor type isolation transformer of capacity 125 KVA, Three phase, 50Hz, Copper wound, oil cooled, class of insulation A, metallic body duly powder coated designed for input Voltage range 415± 5% and output voltage range 415± 5%, Ratio 1:1, Vector group : Dyn 11, Delta-star, Outdoor type with suitable IP protection (CPRI Approval required) with first filling of transformer oil (280 Litre) of requisite dielectric strength upto level, efficiency more than 95%, separate neutral bushing shall be brought out for earthing, Potential difference between neutral to earth less than one volt with all standard fittings like digital temperature meter, adequate number of cooling radiators, lifting hooks one set, Earthing terminal two Nos complete with Over load/ short circuit protection, Note:- Including Integration of Existing LT panel with Isolation transformer, Connection of LT cable. lugs and necessary spares and complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing and commissioning of Indoor Servo Controlled voltage stabilizer of capacity 125 KVA (Confirming to BIS 9815:Part1:1994) Three phase, 50 Hz, Naturally Oil cooled, outdoor with suitable IP protection, unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of 360 L transformer oil in voltage stabilizer upto desired level having following specification. (a) Input voltage 340V-480V, (b) Output voltage stabilized at any deigned/desired voltage 415± 1% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time not to exceed 20 mille seconds (f) Sensitivity (±)1% (g) Rate of correction 8 Volt/second for single phase and 13 V/second for phase to phase (h) Efficiency more than 95% (i) Type of load : three phase, unbalanced type (j) Digital display Voltmeter/Ammeter Protections:- 1. Over load/ Short Circuit protections (MCCB with min 200 A, 25 KA 3 pole) 2. High/ Low voltage cut off 3. By pass arrangement in case of emergency 4. Single phase sequence change protection
Supply, laying and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, FRLS electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, 04 core of size 25 sqmm complete all as specified and as directed. (Location - Exchange substation to WCDMA Tower and EE Hall substation to WCDMA Tower)
M&L for boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine etc as per site requirement for protection of UG cable complete all as directed.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, 03 core of size 95 sqmm complete all as directed.
Supplying and laying Un-reinforced precast concrete cable cover, Class HV Type 1, peak size 300mm x 180mm x 40mm complete all as directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 5652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 5652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Testing resistivity of soil for earthing of equipment including all tools and equipment and labour complete all as specified and directed.
Supply and fixing GI pipe Light grade galvanised 40 mm dia complete with all fitting and laid on floor or wall for cable, earth strip protection complete all as directed by Engineer-in-Charge.
M&L for Earth continuity conductor (20 X 3mm Copper trip) or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn through conduit/pipe or fixed to poles or any other indicated situation complete all as directed.
M&L for Earth continuity conductor (32 X 6mm GI trip) or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn through conduit/pipe or fixed to poles or any other indicated situation complete all as directed.
Supply and fixing cable joining kit for 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
Supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size HT 25x20 cm complete all as directed.
Supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size LT 20x15 cm complete all as directed.
Supply and fix cable joining kit for 11 KV grade cable for indoor termination cold shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
S&F LED street light fitting 35 W Aluminium PDC housing, toughened glass cover, IP 65 protection, pre-wired complete with driver and including suitable GI bracket, clamp, nut, bolts, etc of suitable size, connecting up with twin core twisted flexible copper conductor cable with suitable size
M/S TRIVENI BUILDERS
M/S Ali Trading Co
M/s KUMAR BUILDERS
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .