Electrical Goods/Equipments
GOVERNMENT POLYTECHNIC COLLEGE
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
2 Jul 2026
2 Jul 2026
17 Jul 2026
2 Jul 2026
16 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SINGLE PHASE TRANSFORMER - Single Phase Transformer, Rating: 1 kVA, 50 Hz, Input: 230 V ac
Output: 115 V ac
Type: Air-cooled, single-phase step-down transformer
Properly insulated input and output terminals brought out for safe operation | 2 | Nos. | - | - |
| 2 | THREE PHASE TRANSFORMER - Type: Three Phase Transformer, Rating: 3 kVA
Input Voltage: 415 V ac, 3-Phase, Output Voltage: 230 V ac, 3-Phase
Frequency: 50 Hz
Winding Material: Copper wound
Insulation Class: Class B or higher
Duty: Continuous duty suitable for laboratory use Bench/Floor | 1 | Nos. | - | - |
| 3 | LOAD RHEOSTAT THREE PHASE - Rating: 5.25 kW, Supply: 415 V ac, 3-Phase, 50 Hz
Total Number of Load Steps: 6, Main switch to be provided
Approximate dimensions: 18 × 18 × 22 inches (L × B × H) Comprising special cement-insulated electrical load resistors
Mounted on powder-coated MS panel/enclosure
Individual ON/OFF rotary switches for load selection
Mounted on rubber wheels/casters for portability
Suitable for laboratory load testing applications
Proper insulation, ventilation, and earthing arrangement to be provided | 1 | Nos. | - | - |
| 4 | THREE PHASE CAPACITOR BANK - 3-phase capacitor bank
Rating: 2 kVAR, Voltage: 440 V ac, Frequency: 50 Hz
Heavy duty self-healing capacitor units
Powder coated MS enclosure
Compact panel mounted/floor mounted construction
Proper ventilation arrangement to be provided
Capacitor duty contactor/switch to be provided
Fuse/MCB protection to be provided
Discharge resistors to be provided for safety
Proper earthing arrangement provided | 1 | Nos. | - | - |
| 5 | 3 Phase Auto transformer starter - 3-phase variable autotransformer
Input: 415 V, Output: 0–470 V AC (continuous), Current: 15 A
Copper wound, carbon brush type
Heavy duty toroidal/core construction
Mounted in powder coated MS/CRCA enclosure
Front panel mounted voltage control knob with scale indication
Proper insulated terminals provided
Floor/bench mounted type suitable for laboratory use
Input/Output terminal arrangement provided
MCB/Fuse protection provided
Proper earthing terminal provided
Ventilation arrangement for heat dissipation | 1 | Nos. | - | - |
| 6 | Transformer Oil BDV Test Kit - Transformer Oil Breakdown Voltage (BDV) Test Set
Input Supply: 230 V ac, Single Phase, 50 Hz
Output Voltage Range: 0–60 kV ac
Suitable for testing dielectric strength of transformer insulating oil
Oil test cup with standard electrodes
Transparent safety hood provided over test chamber
Electrode gap adjustable as per standard testing requirements
Interlocking safety switch for hood protection
Automatic tripping protection provided
Tripping current: 10/20 mA at 2.5 mm electrode gap
HT ON switch with zero-voltage start facility
Sample transformer oil to be provided with test kit. | 1 | Nos. | - | - |