| 1 | L1₹77.8 LAccepted-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹80.2 L+₹36,407 (0.46%)Rejected-Finance V P O JAGANOO TEH DISTT UDHAMPUR J K 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹81.8 L+₹1.9 L (2.41%)Rejected-Finance JAGANOO PO JAGANOO JAGANOO DISTT UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹84.3 L
EMD Value
₹1.5 L
Closing Date
8 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE UDHAMPUR
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIRS TO BLDG NO P-12 OF PB ENCLAVE UNDER GE (NORTH) UDHAMPUR
2023_MES_586907_1
CWE/U(N)-99/2022-23
Open Tender
Civil Works
Item Rate
180 days
Udhampur
Class C and cat a(i)
7 documents required · 7 mandatory
₹1,000
GE (North) Udhampur
₹1.5 L
22 Jul 2023
28 Mar 2023
16 May 2023
28 Mar 2023
8 May 2023
19 Apr 2023
29 Mar 2023 - 13 Apr 2023
Amount
Providing and maintaining Barricading on the site 2.5 m high by using MS Pipes or angle iron frame work of verticals at 3 m c/c and horizontals at 0.90 m c/c, Galvalume sheets, Struts, MS Clamps, etc. The verticals shall be embedded/ fixed to concrete pedestals below ground. The rate to include fabricating, cutting and fixing in position MS frame work, painting the same with two coats of approved anti rust paint, etc complete all as specified and directed by Engr-in-Charge. Contractor to get structural design approved by the Engineer. Contractor shall remove and take away the barricading at his own cost on completion of the works.
Chipping/removing loose concrete up to reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc. complete all as specified and directed by Engr-in-Charge.
Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying polymer bond to the old concrete surface before applying Polymer mortar complete all as specified and directed by Engr-in-Charge. Make :- SIKA- SIKA Rust off 100 or SIKA S.B.R or Latex Power FOSROCK - Reebaklens RR or Nitobond AR
Application of Corrosion Inhibitor Providing & applying One coat of Concrete Penetrating Corrosion Inhibitor (Surface applied) which works on Bipolar Inhibition Mechanism on entire concrete surface to be repaired by using brush or spray at 250 ml per Sqm/Coat or as per manufacturer’s specification and prior to application of first coat of anti corrosive coating to reinforcement complete all as specified and directed by Engr-in-Charge.
Providing Micro Concrete jacketing to walls/ columns or beams of thickness upto 75 mm using Polymer modified cement premixed quartz sand aggregate packed in bags of standard manufacture, for high early strength of 40 N/mm sq.cm of approved brand. The dry product is to be mixed with 12.5% water by weight, along with washed and poured into rigid form work moulds & tamped properly, & cured for 3 days complete all as specified and directed by Engr-in-Charge. Payment is to be made by weight premixed of micro concrete product consumed as per site register records. No extra payment shall be made for shuttering or any other material.
Providing and applying Polymer modified cement mortar of average thickness 15-20mm using Polymer in one or more layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster complete all as specified and directed by Engr-in-Charge.
Providing and applying Polymer modified cement mortar of average thickness 30-40mm using Polymer in two layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster complete all as specified and directed by Engr-in-Charge.
Shear Connectors: Make 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars complete all as specified and directed by Engr-in-Charge. (The rates included with 8mm dia TMT bars used as shear connector of any length as per site requirement).
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and includingMS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge.
Bond Coat: Providing & applying One coat of structural grade epoxy bond coat by brush conforming to ASTM-C-882-87 to the prepared concrete surface to be repaired / strengthened. This is applied prior to the application of polymer repair mortar / epoxy mortar / Microconcrete to have monolithic action between old concrete surface and new concrete surface complete all as specified and directed by Engr-in-Charge.
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. complete all as specified and directed by Engr-in-Charge.
Providing precast cement concrete louvres and jallies of 35 mm thick (measured solid), including all mouldings but excluding frame in Nominal Mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:4 (1 cement: 4 fine sand) etc. complete all as specified and directed by Engr-in-Charge excluding plastering of the jambs, sills and soffits.
Demolition of unreinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed by Engr-in- Charge. Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
20mm thick precast machine pressed factory made PCC tiles as in 1:2:4, type B-0, 300x300mm size and 20mm thickness with grey cement & No pigment on bedding layer of 15mm thick cement mortor 1:4 mixed with 5% creosote oil, joined & pointed flush in cement mortor 1:3 complete all as specified and directed by Engr-in-Charge.
Providing and laying water proofing treatment to sunken portion of WCs, bathrooms, etc by applying first layer of slurry of cement @ 0.488kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253kg/sqm this layer allowed to air cure for 4 hrs then applying slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified cementitious composite compound @0.126kg/sqm and allowed to aircure for 4 hrs and joints seal with sealing compound as approved by GE. Note: (i) Before laying of lime concrete joints of trap/WC/Soil pipes shall be properly sealed with sealing compound of Roofex/Forre/FOSROC and provn of P or S trap & Nahani /Floor traps with long arm complete all as specified and directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:3, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Lean concrete using 40mm graded stone aggregate as in 1:5:10 as in sunken portion treatment, complete all as specified and directed by Engr-in-Charge.
Water proofing treatment to the chajja after removing old plaster and roughening the surface and finishing the top surface with 20mm thk. 1:2 cement slurry plaster with approved water proofing compounds and neat cement finish, the rate also includes for 1:3 cement slurry facia of chajja to match the new surface (actual area treated will be paid) complete all as specified and directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Supply only integral water proofing compound.
12mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:3, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
1 to 1.20mm thick wall care putty on wall, complete all as specified and directed by Engr-in-Charge.
Removing any kind of debris/Demolished building material outside A-1 Def land including loading in truck and conveying day to day basis to beyond the lead included in the rates, including loading, unloading and stacking at the destination approved dumping point etc. complete. With all lifts and lead outside MD Land 1 to 2 Km distance, complete all as specified and directed by Engr-in-Charge.
Note :- The rates Quoted against Ser item 01 to 08, 10,11,14 &16 here in before shall includes the following:- (i) Work shall be executed only through authorized applicator of manufacturer. (ii) All scaffolding work and safety measures such as provision of props and supports shall be of Steel and extent of provision shall be to the entire satisfaction of GE. (iii) After obtaining approval of the makes of products the Contractor shall give a letter from the manufacturer regarding the details of agency and name of Person to be deployed for carry out repair & supervisor of work. (iv) The T&P shall be strictly as per manufacturer instruction. (v) Necessary Jacks shall be errected to support various floors before exposing columns/ beams for repair and it shall also be ensured that no damage is made to the existing structure during repair process & all safety norms shall be followed. (vi) Contractor shall furnish a written guarantee for structure repairs carried out under above ser items of BOQ for a period of five years. An amount to the tune of 5% of total amount Quoted against ser item 01 to 08, 10,11,14 & 16 or Rs.50,000.00 whichever is less shall be held back from Contractors payment as security deposit against the guarantee period of 5 years from certified date of completion. Which shall be refunded to him after expiry of this period. Alternatively Contractor may give interest bearing deposit infavour of GE for five year for the Sum above which shall be refunded back after satisfactory completion of five year from date of completion.
(vii) Close vigin & promptness on the progress and joint measurement has to be ensured and Photographic evidence in Soft copy for complete repair process for each structural members shall be taken by Contractor & handed over to GE. (viii) The Construal chemical/ Fibers to be used shall to of following approved brands :- (a) Sika (b) Chembond (c) Hilti (d) BASF (e) Dr.Fixit (f) FOSROC (g) CICO (h) STP Limited.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Taking down shutters of any description exceeding 1.00 square metre and not exceeding 2.00 square metre each complete, all as specified and directed by Engineer-in charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 28 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Dismantling PVC/wooden boarding any discription fixing in any position with nail complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 25 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Dismantling water tank of capacity exceeding 500 litres but not exceeding 1000 litres each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
Dismantling water tank of capacity exceeding 250 litres but not exceeding 500 litres each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 41 above but except brick.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Reinforced cement concrete, 1:11/2:3, type A-1 (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, shelves and like ccomplete all as specified and directed by Engr-in-Charge.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide complete all as specified and as directed by Engineer-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed by Engr-in-Charge.
16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Moulding on sides of granite slabs 16-18mm thick complete all as specified and as directed by Engineer-in-Charge.
35mm thick factory made, 2nd class hard wood glazed and skelton shutter open rebated and prepare to receive glass, gauge etc for window/ventilator edges of framing plain, chamfered rounded fitted with cut and mitred beads for securing glass etc, with member size as specified in SSR Part-I clause 8.24(a), complete all as specified and as directed by Engr-in-Charge.
S&F 35 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides, complete all as specified and as directed by Engr-in-Charge.
35mm thick flush shutters, solid core construction, with block board core and decorative laminates of approved colourand pattern on both faces complete all as specified and directed by Engineer-in-charge.
M & L for pressed steel frames for doors of size 105mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as direceted by Engr-in-Charge.
M & L for pressed steel frames for doors of size 165mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engr-in-Charge.
Refixing door shutter of any description exc 1.00 Sqm and not exc 2.00 Sqm each in same opening after taking down,easing and adjusting and also refixing builders hardware as required; complete all as specified and as directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
S & F powder coated (of approved colour ) aluminium sections as in frame & shutter of windows, ventilators as in sliding/ openable/ louvers/ fixed type with and including necessary rolling for smooth moving & locking arrangement, etc fixed to wall including, preparation of disturbed portion both side (internal & external surfaces of wall) match with existing surface treatment and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face) complete all as specified as directed by Engr-In-Charge. Make : JINDAL/ HINDALCO/INDALCO
S&F Powder coated aluminium handles of size 100mm in built with locking arrangement for aluminium windows fixed with screws to window shutters, complete all as specified. complete all as specified and as directed by Engr-in-Charge.
S&F Powder coated Aluminium Hinges suitable for aluminium openable windows 125mm long match with ventilator/window shutters fixed with screw complete all as specified and as directed by Engr-in-Charge.
S & F Powder coated aluminium tower bolt 150mm long to ventilators fixed with screws, complete all as specified and as directed by Engr-in-Charge
5mm frosted/ tinted sheet glass, ordinary quality and glazing with rubber neoprene packing for aluminium doors/windows in square/rectangular exc 0.5 sq. m in each pane, complete all as specified and as directed by Engr-in-Charge.
5mm frosted/ tinted sheet glass, ordinary quality and glazing with rubber neoprene packing for aluminium doors/windows in square/rectangular not exc 0.5 sq. m in each pane, complete all as specified and as directed by Engr-in-Charge.
Non skid, ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 10 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes , complete all as specified and as directed by Engr-in-Charge.
Coloured vitrifired (double charged) tiles 10mm thick (square) polished, light shade, area of each tiles exc 0.38 sqm but n.exc 0.64Sq.m (min. size 800mm x 800mm) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement incl 10mm thick screed bed in CM (1:4) complete all as specified and as directed by Engr-in-Charge.
All as per serial item No. 63 here in before but on vertical surfaces as in skirting/dado over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete as in 1:3:6, type C-1 (Using 20mm graded stone aggregate) for water tank staging above roof finished even & fair, complete all as specified and as directed by Engr-in-Charge.
Glazed ceramic coloured digital tiles in vertical surfaces of wall of size 450mm x 300mm x 7 mm thick as approved pattern approved by GE, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in Cement mortar 1:4 as in skirting, dado, etc, complete all as specified and as directed by Engr-in-Charge.
50mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even & smooth with out using extra cement incl making joints 10mm wide and 30mm deep at spacing n more than 2.5m and at corners at mandatory and filled with sealing compound grade B complete all as specified and as directed by Engr-in- Charge.
S&F in repair 18 mm thick prelaminated medium density fibre (MDF) boards, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws as in shelves, etc, complete all as specified and as directed by Engr-in- Charge.
S&F in repairs telescopic drawer side channel of std size and incl of roller for moving drawer, mild steel bright finish, or electrogalvanised, for modular kitchen, complete all as specified for modular kitchen.
S&F in repairs Stainless steel multipurpose basket in wooden drawer/partitions for storing rations of various types made of 3 to 4mm dia stainless steel rods, fixed in side partitions etc. fixed, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Stainless steel of 3 to 4mm dia luddle-craddle hanging stand for cutlery, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair stainless steel zero crank hinges (auto) fancy type (with Euro concealed hinges) fixed to shutters in cupboards of standard size and shape for modular kitchen, complete all as directed by Engr-in-Charge for modular kitchen.
100 mm aluminium handles, cast type anodised complete all as specified and as directed by Engineer-in-Charge.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixing with wooden/steel beads, complete all as specified and as directed by Engineer-in-Charge.
Stainless steel wire cloth fixed in repairs 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixing with wooden/steel beads, complete all as specified and as directed by Engr-in-Charge.
200mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed by Engr-in- Charge.
S&F in repairs 200mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section, complete all as specified and directed by Engr-in- Charge.
S&F in repairs mild steel cold rolled butt hinges medium weight 100 mm long fixed to pressed steel/angle iron frames by welding, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs aluminium alloy sliding door bolt 250 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed by Engr-in-Charge.
300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed by Engr-in-Charge.
150 mm size mild aluminium handles cast type anodised complete all as specified and as directed by Engr-in-Charge.
Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Floor door stopper of alumium body powder coated and tongue anodised with land drawn steel spring overall lengthof cover plate 140mm fixed with screw, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, size 140 mm, complete all as specified and directed by Engineer-in-Charge.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified and as directed by Engr-in-Charge.
100mm size stainless steel hinges complete all as specified and as directed by Engr-in-Charge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, as in repairs, complete all as specified and as directed by Engr-in-Charge.
125 mm size hasp and staple,safety type, aluminium anodised,including bolt to hinge plate and fixed with screws, as in repairs, complete all as specified and as directed by Engr-in-Charge.
150mm size aluminium handles,cast type, anodised as in repairs, complete all as specified and as directed by Engr-in-Charge.
Double action spring hinges 125mm, mild steel with steel wire spring, stove enamelled, black fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Stainless steel 25mm dia (curtain rod) with fixing of domes, with stainless steel brackets etc. fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and ceiling or laid under floors etc complete all as specified and as directed by Engr-in-Charge.
All as per Serial Item No 94 here-in-before but except tubing (Old serviceable tubing as retrieved vide item above shall be reused under this item).
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls ceiling and or laid under floors etc complete all as specified and as directed by Engr-in-Charge.
All as per Serial Item No 96 here-in-before but except tubing (Old serviceable tubing as retrieved vide item above shall be reused under this item).
25mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls ceiling and or laid under floors etc complete all as specified and as directed by Engr-in-Charge.
All as per Serial Item No 98 here-in-before but except tubing 25mm (Old serviceable tubing as retrieved vide item above shall be reused under this item).
Cutting screweing existing steel tubing for alteration or addtion for 25 to 32mm dia pipe, complete all as specified and as directed by Engr-in-Charge.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3, for concealed water tubing etc and maing good, cutting exc 10cm and not exc 20cm girth, complete all as specified and as directed by Engr-in-Charge.
Vitreous china wash down water closet (pedestal pattern) snow white suitable for p or s trap complete, including connection to drain pipe and to flushing pipe antisyphonage pipe etc, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Make-CERA cat part No. S1050101/02, Jaquar –CNS-WHT-WH 10 or equivalent of Kohler make as approved by GE.
Plastic water closet seat, white colour closet pattern with flat bottom and cover and incl mild steel chromium plated or aluminum hinges device complete fixed in repairs , all as specified. Make-CERA cat part No. B1510121, Jaquar –CNS-WHT-WCS 1 or equivalent of any approved make as approved by GE.
Vitreous china squalting pan, orissa pattern size 580 x 440 mm white with integral foot rests, P or S trap long body with integral foot rest and fixed with cement concrete bedding complete all as per specified. (Fixed in Repair). Make-CERA, Cat part No. 2071, Jaquar –CNS-WHT-OP01 or equivalent of Kohler make as approved by GE.
PVC low level flushing cistern 10 ltrs capacity, valve less, syphonic action type, white, with inlet, ball valve, float and handle including brackets, PVC 32mm dia flushing pipe etc., fixed in repairs,complete all as specified and directed.Make-CERA cat part No.B1020101, Jaquar or hindware as approved by GE.
Vitreous china,white, wash hand basin, flat back of size 550x400mm, white including MS brackets and pedestal pattern including cutting for and pinning including 32mm dia CP brass waste coupling and PVC waste pipe, fixed in repair complete all as specified.Make-CERA cat part No. S 2040105 for WHB & for pedestal cat part No.S 2090101, Jaquar- SLS-WHT-0611F for WHB and SLS-WHT-1510 for pedestal or equivalent of Kohler as approved by GE.
CP Towel Ring 200mm dia fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make-Jaquar, AQN-7721, Cera-F 5002105 or equivalent of any approved make as approved by GE.
20mm dia brass chromium plated tubular towel rails, D type,60 cm long between flanges Fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make -Jaquar cat part no. CAN-1111NM, Cera- F5007103 or equivalent of any approved make as approved by GE.
Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated brackets, guard and railing 60cm long fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make -Jaquar cat part no. AKP-35771P, Cera-F 5001114 or equivalent of any approved make as approved by GE.
Corner Glass self ( With CP brakets) 225 x 225 mm complete all as specified and as directed by Engineer-in-Charge. Make-Jaquar cat part No. CAN-1173, Cera- F 5005102 or equivalent of any approved make as approved by GE.
Single lever wall mixer 3 in 1, with provn of over head shower & hand shower, telephonic type, brass, chromium plated, fancy type, with capstan head handles with lettered 'hot' and 'cold', screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, with provision for both hand shower and over head shower, fixed in repair, complete all as specified and as directed by Engineer-in-Charge. Make : Jaquar cat part No. FUS-29281, Cera- F 2007403 or equivalent of any approved make as approved by GE.
Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' & 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make : Jaquar, Cat part No. SOL-6169B, Cera- QTF 2006461 or equivalent of any approved make as approved by GE.
Hand shower 90mm round shape (telephonic shower), chromium plated, with 1500mm long 15mm bore chrome finish flexible pipe with hook, fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar-code HSH-1727,SHA-571, Cera-F 7030105 for hand shower & F 8070401 for flexible tube or equivalent of any approved make as approved by GE.
Shower rose, brass, chromium plated, with CP arm 120mm dia with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe or union as in repair complete all as specified and as directed by Engineer-in-Charge. Make : Jaquar cat part No. OHS-1719, Cera- F 7040101 for arm & F 7020305 for shower rose or equivalent of any approved make as approved by GE.
Angle valve, brass, chromium plated, fancy type, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and as directed by Engineer-in-Charge. Make : Jaquar cat part No- CON-053KN, Cera- QTF 2006201 or equivalent of any approved make as approved by GE.
Bib taps, brass, chromium plated, fancy type, long nose, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and as directed by Engineer-in-Charge. Make : Jaquar cat part No.- CON-037KN, Cera-QTF 2006152 or equivalent of any approved make as approved by GE.
Health faucet, brass, chromium plated, with 1000mm long 8mm dia chrome finish flexible pipe with wall hook, fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make - Jaquar cat part No- ALD-573, Cera- F 8030103 or equivalent as approved by GE
Jet spray, brass, chromium plated, heavy duty, including flexible pipe suitable for 15mm bore water connection; for EWC fixed complete all as specified and as directed by Engineer-in-Charge.
PVC flexible connections 450mm long 15mm dia with brass flange nuts & washers complete all as specified and as directed by Engineer-in-Charge. Make-Jaquar, cat part No. ALD-805B, Cera-CG 107 or equivalent of any approved make as approved by GE.
PVC flexible connections 600mm long 15mm dia with brass flange nuts & washerscomplete all as per the direction of Engr-in-Charge.
Stop valves, brass, fancy type with flange, chromium plated with long shank and cup (concealed type), screwed down high pressure, with capstan head handle, screwed both ends for iron pipe or for unions and fixed. Make : Jaquar cat part No.CQT-23083, Cera- F 1014751 for exposed part & F 4060102 for consealed part or as approved by GE.
Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cromium plated screws, fixed in repair complete all as specified and as directed by Engr-in-Charge. Make : Jaquar, Cera- cat No. F 5007106 or equivalent as approved by GE.
CP brass grating 100mm dia, centre hole, fixed in repair complete all as specified and as directed by Engr-in-Charge.Make- Prayag Cat No. FT-70 or equivalent of any approved make as approved by GE.
CP brass grating 100mm dia, fixed in repair complete all as specified and as directed by Engr-in-Charge. Make- Prayag Cat No. FT-03 or equivalent of any approved make as approved by GE.
Toilet paper holder, brass, chromium plated, heavy duty, fixed with brass screw complete all as specified and as directed by Engr-in-Charge. Make- Jaquar cat part No. ACN-1153N, Cera-F 5007109 or equivalent of any approved make as approved by GE.
Tumbler holder, brass, chromium plated, heavy duty, having suitable recesses made for hanging necessary bath items complete fixed with brass screws as per manufacturer's instructions. Make: Jaquar Cat part No. AQN-7741, Cera- F 5002107 as approved by GE.
Sink wall mixer, brass, chromium plated, fancy type, with capstan head handles screwed down high pressure, with lettered 'hot' and 'cold', including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat part No. CON-309KN, Cera- F 2007501 or equivalent of any approved make as approved by GE.
Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including waste coupling and waste pipe & bedding in CM to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 1040mmx 510mmx 203mm bowl size 510mmx405mmx203mm, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Make: Prayag, Cat No. 1244D of prayag or equivalent of any approved make as approved by GE.
S&F Stainless steel peg sets of six pegs of standard quality fixed with brass screws as approved by Engr-in- charge and fixed etc, complete all as specified and as dircted.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity (Tripple layer) white in colour including water tank cover (internaly/interlocking arrangment for water tank cover), hoisted and fixed in position including tank nipple inlet & outlet and connecting up pipes, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity (Tripple layer) white in colour including water tank cover (internaly/interlocking arrangment for water tank cover), hoisted and fixed in position including tank nipple inlet & outlet and connecting up pipes, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
PTMT ball valve 20mm dia high pressure with polythene float and fly nut complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair complete all as specified and as directed by Engr-in-Charge.
1.60mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel section of angle, tee, flats,and plates as in roof trusses, purlines, rails, etc and the like fixed with angle cleats and connecting plates including welding,Gde FE-410-0 or FE-310-0, complete all as specified and as directed by Engr-in-Charge.
Nails of 50mm to 80mm in length fixed with welding to MS sheet, complete all as specified and as directed by Engr-in-charge.
Taking down eaves gutters and rainwater pipes/soil pipes (any size, type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., for (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
All as per description of srl item No 140 above but except pipes, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 110mm bore PVC (SWR) bends any radius, complete all as specified and as directed by Engr-in-Charge.
S & F repair stack clamps made out of 50mm x 5mm flat iron & 15 mm dia round iron steys, including bolts and nuts and securing ends of syays to wall or roof for 110mm bore, complete all as specified and as directed by Engr-in-Charge.
150 mm x 150mm size Salt-glazed stoneware gully traps, square or round mouthed, type ‘P’ and jointed, ISI marked complete all as specified and as directed by Engr-in-Charge.
S&F in repairs cast iron multi floor trap with grating to 75mm bore including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 complete all as specified and directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore in repair, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore in repair, complete all as specified and as directed by Engr-in-Charge.
Re-fixing only pipe execpet pipe Sand Cast iron soil, waste and vent pipes, 100mm dia in any length with or without ears with cement joints, fixed to wall in repair, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 75mm bore in repair, complete all as specified and as directed by Engr-in-Charge.
Re-fixing only pipe execpet pipe Sand Cast iron soil, waste and vent pipes, 75mm dia in any length with or without ears with cement joints, fixed to wall in repair, complete all as specified and as directed by Engr-in-Charge.
110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all as specified and as directed by Engr-in-Charge. (ISI Marked)
Fixing only in repairs 75mm bore bends(any radius) measured larger bore complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 100mm bore bends/reducer (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Engr-in-Charge.
Fixing only in repairs 100mm bore bends(any radius) measured larger bore complete all as specified and as directed by Engr-in-Charge.
S & F in repairs branch pieces 75mm bore Cast iron, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval accessed door, complete all as specified and as directed by Engr-in-Charge.
S & F in repairs branch pieces 100mm bore Cast iron, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval accessed door, complete all as specified and as directed by Engr-in-Charge.
S& F Cast iron cowls of 75mm bore as in repair, complete all as specified and as directed by engineer-in-charge.
S& F Cast iron cowls of 100mm bore as in repair, complete all as specified and as directed by engineer-in-charge.
Dismantling cast iron or reinforced concrete drain pipes, any size up to 100mm bore, jointed in in cement mortor and taking out of trenches if required, complete all as specified and as directed by Engineer-in-charge.
M&L 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed by Engineer-in-charge.
M&L 200 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed by Engineer-in-charge.
Cutting into existing manholes for connecting new drains of 150mm dia internal bore) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate smooth finished and reforming benching as required complete all as specified and as directed by Engineer-in-charge.
Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in concrete bed to drain pipes 150mm internal bore including packing under and hunching against the sides of pipes after they are laid and tested, in complete all as per the direction of Engr-in-Charge.
All as per srl item No.163 above but 200mm dia complete all as specified and as directed by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drains pipes jointed in cement mortar of dia 150mm and taking out of trenches/walls if required (of any bore bore) complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drains pipes jointed in cement mortar of dia 200mm and taking out of trenches/walls if required (of any bore bore) complete all as specified and directed by Engr-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Complete removing existing treatment using grinding machine / Mechanical means (as per instructions) on walls including scraping, removing all mud, cake with wire brush and gunny bags from old plastered surfaces and preparation of surfaces by applying minimum 1 to 1.2mm thickness of white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and as directed by Engr-in-Charge.
Rubbing, stopping existing treatment on ceiling including scraping, removing all mud, cake with wire brush and gunny bags from old plastered surfaces and preparation of surfaces by applying 1 to 1.2mm thickness of white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and as directed by Engr-in-Charge.
Preparation of new plastered surfaces of wall by applying 1 to 1.2mm thick white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and as directed by Engr-in-Charge.
Preparation of new plastered surfaces of ceiling by applying 1 to 1.2mm thick white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over and including a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old decorated plastered surfaces and applying two coats of white wash on ceiling, complete all as specified and as directed by Engr-in-Charge.
Preparation of old decorated plastered surfaces and applying one coat of white wash on walls, complete all as specified and as directed by Engr-in-Charge.
Preparation of old wooden painted surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr- in-charge
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
Preparation of new or previously untreated steel and iron surface of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old steel surfaces not exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-1 (using 20mm graded crushed stone aggregates) as in sub base, complete all as specified and as directed by Engr-in-Charge.
50mm thick sand filling in floors or pavings, laid in layers, spread, levelled, and blinded with earth and rammed including watering, complete all as specified and as directed by Engineer-in-Charge.
Machine pressed rubber moulded manufactured / compacted by vibrating table method pre-cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand complete all as specified and as directed by Engr-in-Charge.
S&F plain fillets square of rectangular or triangular in section of Iind class Hard wood sectional area exc 6 Sqcm but nexc 13 Sqcm fixed with nails as fixed in repair, complete all as specified and as directed by Engr-in-Charge.
S&F magnet catchers 50mm steel plate MS body and striking plate incl letting in & fixed, complete all as specified and directed by Engr-in-Charge.
M&L for Providing & fixing, pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in kerb stones and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
S & F of Stainless steel pipe 50 mm dia 16 gauge and grade 304 fixed in vertical/Horizontal position cut to length required and welded complete all as specified and as directed by Engr-in-Charge.
S & F of Stainless steel pipe/square 35 mm dia 16 gauge and grade 304 fixed in vertical/Horizontal position cut to length required and welded complete all as specified and as directed by Engr-in-Charge.
Supply and fix of Stainless steel pipe/square 16 mm dia 16 gauge and grade 304 fixed in vertical/Horizontal position cut to length required and welded complete all as specified and directed by Engr- in-charge.
Supply and fix of grade 304 stainless steel foot caps and top caps of 50 mm dia and 16 gauge thickness fixed to vertical pipes including necessary welding etc complete all as specified and as directed by Engr-in-Charge.
Supply and fix of grade 304 stainless steel foot caps and top caps of 35 mm dia and 16 gauge thickness fixed to vertical pipes including necessary welding etc complete all as specified and as directed by Engr-in-Charge.
Supply and fix of grade 304 stainless steel foot caps and top caps of 16 mm dia and 16 gauge thickness fixed to vertical pipes including necessary welding etc complete all as specified and as directed by Engr-in-Charge.
Site clearance in soft/ loose soil and dressed with proper manner upto desire satisfaction of Engr-in-Charge, Complete all as specified and as directed.
Cutting holes in brick walls/ RCC beams exc one brick by using mechanical means for placing spout and making good after provision of pipe, complete all as specified and as directed by Engr-in-Charge.
M & L for GI pipe 40mm dia as in spout for sunken portion, complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume / Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513 (AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397), as in roof covering / clading to wall fixed with self taping screws, colour / exterior coat of silicon modified polyster / BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer, all fixed with galvanised self drilling self tapping fastener (12-14x55 with EPDM seals), complete all as specified and as directed by Engr-in-Charge.
Cutting holes in brick walls not exc 150Sqcm built in lime mortar or cement concrete 1:2:4, type B-1, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store (Accessories or components to be provided free for replacement by department) complete all as specified and as directed by Engr-in-Charge.
Taking down unservicable/ servicable MCB DB's/AC box to deposite in store for keeping in safe custody for re-use or for taking in schedule of credit of any size/rating, complete all as specified and directed by Engr -in- Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick and all accessories for one light / fan controlled by one switch with 1.25mm thick pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete including cutting, chasing the surface and then making good the same in CM 1:3, complete all as specified & directed by Engr-in-Charge.
Description all as per item No 203 above but for one fan/exhaust fan/Air ciculator/bell point controlled by one way switch.
Description all as per item No 203 above but 05 Amp socket outlet controlled by one switch on same board with other switch.
Description all as per item No 203 above but 05 Amp socket outlet controlled by one switch on independent board .
Description all as per item No 203 above but for light point controlled by 2-two way switch.
Description all asper item No 203 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
M&L for modular socket, 06 Amp 5 pin flush type 240 Volts with polycarbonate body, complete all as specified and as directed by Engr-in-Charge.
M&L for modular socket outlet, 6 pin 06 & 15 Amp multi purpose 2 in 1, flush type 230 Volts with polycarbonate body, complete all as specified and as directed by Engr-in-Charge.
M&L for modular Switch piano, single pole, one way, 06 Amp 240 Volts with polycarbonate body, complete all as specified and as directed by Engr-in-Charge.
M&L for modular Switch piano, single pole, two way, 06 Amp 240 Volts with polycarbonate body, complete all as specified and as directed by Engr-in-Charge.
M&L for modular Switch piano , single pole, one way, 16 Amp 240 Volts with polycarbonate body, complete all as specified and as directed by Engr-in-Charge.
Modular type stepped type fan regulator 120W, 230V 50 C/S, Deluxe 2 Modular electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 203.00 here-in-before but for geyser point on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor along with PVC insulated and unsheathed FRLS 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
S&F of Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 18/20Watt LED with integral electronic driver, fixed in repair, complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
S&F of Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10/12 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
S&F of Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 5/6 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
S&F of Environmental friendly, energy saving, surface mounted, decorative LED 9/10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Re-fixing any type LED tube light fittings of 5W/12W/20W/'2x2' panel light and LED bulk head fitting 9W as obtained from Srl item No. 202 above complete with all fixing accessories complete all as specified and directed.
M&L for Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 6 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
S&F Sheet metal enclosures for distribution board when MCB to be used TPN 4 way ( 8+12 Module) 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions, complete all as specified and as directed by Engr-in-Charge.
M&L for MCB 20 to 63 Amps TPN 415V, complete all as specified and as directed by Engr-in-Charge.
Modular bell push single pole one way 6 Amps 1 module type complete all as specified and directed by Engr- in-charge
Bell (ding dong type), AC electronic type, 230 volts, single pole, fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 40 Amps, 'C' series 10 KA 240 Volts including providing aluminium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Taking down the existing geyser of any capacity carefully and shifting to the store and re-fixing the same after completion of B/R works, complete all as specified and as directed by Engr-in-Charge.
Supply and fix sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 16 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully ceiling/exhaust fan any type and any sweep and removing fan blade including cleaning all dust particle and filling cavities with filler materials, oiling, greasing including painting fan and blades complete with one coat of synthetic enamel white paint by spraying and writting Ser No/MES No with black paint complete and assemble the same along with all fixing connecting accessories and fixing in same position along with all new electric wire connection from ceiling rose to fan, etc. complete, all as specified and as directed by Engineer-in-Charge. Note:- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
Taking down care fully old electric panel by descrewing from wall after all incoming and outgoing connections and making good all disturbed surface of wall including taking out all energy meters and MCCB 160 Amps four pole without damaging for fixing in new panel, complete all as specified and as directed by Engr-in-Charge.
Supply and installation, testing and commissioning factory made LT control panel board of Each adequate size totally enclosed front opening type cubical , floor mounted and indoor type made out of 2.00 mm thick MS sheet with base frame of angle iron of size 40x40x4mm thick provided with copper bus bar - 04 nos with color coated sleeves of capacity 1.5 times of incomer and internal wiring with PVC insulated copper conductor cable of adequate size for making connections to various eqpts / accessories incl powder caoated painting ( internal & externally ) complete over a coat of red oxide primer all as specified CPRI approved and with PCC foundations complete with comprising of following accessories- (a) Fixing only electric meters with complete -08 Nos properly isolated from panel body by means of providing backelite sheet not less than 3.00 mm thick as base plate cable connections ( b ) S & F MCCB 160 Amp TPN Four pole 415 Volt ( c ) S & F MCB TPN 40 to 63 Amp 415 Volt - 08 No s ( d ) S & F RYB indicator ( set of three ) -01 sets .
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 50 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 2009 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
HANS RAJ SHARMA
KALSOTRA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .