Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.3 LAdmitted-Finance | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | sri sai leela electrical projects L1 |
|---|---|---|---|---|
| 1.00Solar Plants | ||||
| 2.00 | Cost of Non - Comprehensive Annual Maintenance Contract of solar plant of total installed capacity of 3.86 MWp as per the list installed at the roof top of the building that includes routine , preventive & break down maintenance for period of One year as per the scope and detailed specifications. The Contractor should deploy team of 1 Engineer and required no. of manpower for carrying out the preventive and breakdown maintenance as per the schedule for the entire period of contract. Any additional manpower required for attending breakdowns shall be in the scope of the contractor.Inverters will be covered under warranty by IIT, Madras and co ordinating with the OEM for rectification/ replacement of the Inverters under warranty is under the scope of the contractor. | 12 | Month | 2,00,600 ₹24,07,200 Lowest |
| 3.00 | Supply and installation of Solar Photovoltaic Module of required capacity consisting Mono/Poly Crystalline silicon solar cells manufactured in India as per the latset AMM List of MNRE 2022 conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Make and model shall be got approved before supply. | 20 | kWp | 12,000 ₹2,40,000 Lowest |
| 4.00 | Supply and cabling of 4 Sq.mm DC Solar copper cable from Solar panels to the DCDB with proper cable dressing with suitable cable tie in the already available channel/PVC pipe/GI duct etc at solar power plants available in various buildings.. | 1,000 | Metre | 68 ₹68,000 Lowest |
| 5.00 | Supply and providing suitable MC4 connectors for DC cabling as required in the DC array part upto DCDB at solar power plants available in various buildings. | 500 | Nos | 120 ₹60,000 Lowest |
| 6.00 | Supply and fixing of following 32 mm medium class PVC conduit alongwith accessories in surface/rececess/wall/floor/structure including cutting the wall and making good the same in case of recessed conduit is required at solar power plants available in various buildings. | 250 | Metre | 80 ₹20,000 Lowest |
| 7.00 | Supply, Installation, Testing and commissioning of cumulative capacity of Solar Grid Tie Inverter as per the attached Technical Specification to IIT Madras. Rate quoted shall be inclusive of transportation, taxes and all other charges. Capacity of the Individual inverter will be informed during the tenure of the contract as and when required. Approved Make : Fronius / Sungrow / Delta / Polycab / Hitachi / Deye Make and model shall be got approved before supply. | 100 | kWp | 5,800 ₹5,80,000 Lowest |
| 8.00Solar Water Heating System | ||||
| 9.00 | Non comprehensive Annual maintenance contract of Flat plate Collector Solar Water Heating HTF based System with water tank made out of stainless steel confirming to SS 304 insulated with PU foam. The 500 LPD with 4 collectors and 1000 LPD with 8 nos of collectors. The out flow temperature is an average of 60°C. Collectors as per BIS and approved as per MNRE specifications. Collector equipped with anti-condensation system and as per the enclosed specfication vide Annexure A | 12 | Month | 1,29,800 ₹15,57,600 Lowest |
| 10.00Supply & repLacement following accessories in the existing solar water system. | ||||
Tender Value
₹56.6 L
EMD Value
₹1.1 L
Closing Date
27 Oct 2025, 3:00 pmClosed
Executive Engineer (Electrical)
Engineering Unit, Admin Block 3rd Floor, IIT Madras CHENNAI-600036
Non-Comprehensive Annual Maintenance Contract of Solar Plants installed at roof top of various Hostel and Academic zone building and Non-Comprehensive AMC of Solar water system at IIT Madras for the year 2025-26
2025_IITM_252084_1
26/2025-26/ELDB
Open Tender
Electrical Works
Item Rate
365 days
IIT MADRAS CHENNAI
All required documents as specified in the tender
2 documents required · 2 mandatory
₹0
₹1.1 L
7 Nov 2025
11 Oct 2025
28 Oct 2025
11 Oct 2025
27 Oct 2025
12 Oct 2025
11 Oct 2025 - 14 Oct 2025
Solar Plants
Cost of Non - Comprehensive Annual Maintenance Contract of solar plant of total installed capacity of 3.86 MWp as per the list installed at the roof top of the building that includes routine , preventive & break down maintenance for period of One year as per the scope and detailed specifications. The Contractor should deploy team of 1 Engineer and required no. of manpower for carrying out the preventive and breakdown maintenance as per the schedule for the entire period of contract. Any additional manpower required for attending breakdowns shall be in the scope of the contractor.Inverters will be covered under warranty by IIT, Madras and co ordinating with the OEM for rectification/ replacement of the Inverters under warranty is under the scope of the contractor.
Supply and installation of Solar Photovoltaic Module of required capacity consisting Mono/Poly Crystalline silicon solar cells manufactured in India as per the latset AMM List of MNRE 2022 conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Make and model shall be got approved before supply.
Supply and cabling of 4 Sq.mm DC Solar copper cable from Solar panels to the DCDB with proper cable dressing with suitable cable tie in the already available channel/PVC pipe/GI duct etc at solar power plants available in various buildings..
Supply and providing suitable MC4 connectors for DC cabling as required in the DC array part upto DCDB at solar power plants available in various buildings.
Supply and fixing of following 32 mm medium class PVC conduit alongwith accessories in surface/rececess/wall/floor/structure including cutting the wall and making good the same in case of recessed conduit is required at solar power plants available in various buildings.
Supply, Installation, Testing and commissioning of cumulative capacity of Solar Grid Tie Inverter as per the attached Technical Specification to IIT Madras. Rate quoted shall be inclusive of transportation, taxes and all other charges. Capacity of the Individual inverter will be informed during the tenure of the contract as and when required. Approved Make : Fronius / Sungrow / Delta / Polycab / Hitachi / Deye Make and model shall be got approved before supply.
Solar Water Heating System
Non comprehensive Annual maintenance contract of Flat plate Collector Solar Water Heating HTF based System with water tank made out of stainless steel confirming to SS 304 insulated with PU foam. The 500 LPD with 4 collectors and 1000 LPD with 8 nos of collectors. The out flow temperature is an average of 60°C. Collectors as per BIS and approved as per MNRE specifications. Collector equipped with anti-condensation system and as per the enclosed specfication vide Annexure A
Supply & repLacement following accessories in the existing solar water system.
2000w heating element with thermostat
Make up tank of 2 litres capacity made up SS 304 to suit the existing system
Glass for HTF based solar collector
Charges for insulating the pipe of 40/50mm dia with rock wool/PUF covered with aluminium cladding
Descaling of Collectors of SWH using Scalgun SAF liquid.
500 LPD SWH system
1000 LPD SWH system
Towards Plumbing spares as and when required.
500 LPD SWH system
1000 LPD SWH system
2000 LPD SWH System
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TenderNoT26.pdf
Tender Documents • 1.74 MB
PriceBidForViewT26.pdf
Other Document • 0.69 MB
BOQ_289534.xls
BOQ • 0.30 MB
Solar-Water-Heater-Details.pdf
Additional Documents • 0.18 MB
Solar-Plant-Details.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .