Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC 61 LAALA LAJPAT RAI COLONY BHOPAL M P 462023 | BHOPAL | MADHYA PRADESH | 462023 | ₹7.1 Cr Quoted ₹7.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹7.3 Cr+₹12.5 L (1.74%)Rejected-Finance 106 AGARWAL AND COMPANY PROFESSOR COLONY OPP OF WALL FORT CITY RING ROAD NO 01 RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | ₹7.3 Cr+₹12.5 L (1.74%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹7.6 Cr+₹36.4 L (5.06%)Rejected-Finance | ₹7.6 Cr+₹36.4 L (5.06%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹7.6 Cr+₹37.9 L (5.27%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹7.6 Cr+₹37.9 L (5.27%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹7.8 Cr+₹60.6 L (8.43%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹7.8 Cr+₹60.6 L (8.43%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹7.9 Cr
EMD Value
₹7.2 L
Closing Date
31 Jul 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
ADDN ALTN RENOVATION AND UPGRADATION OF BUILDING NO P-213, P-385A AND P-385B AT NDA KHADAKWASLA
2023_MES_605459_1
CA NO CEPZ/PNA/TOKEN-05 OF 2023-24
Open Tender
Civil Works
Item Rate
540 days
NDA Khadakwasla
Class S category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE NDA Khadakwasla
₹7.2 L
Yes
7 Aug 2023
24 Jun 2023
2 Aug 2023
24 Jun 2023
31 Jul 2023
17 Jul 2023
26 Jun 2023 - 3 Jul 2023
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed,
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including removal of rubbish off outside MD land complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including removal of rubbish off outside MD land complete all as specified and as directed.
Material and labour for providing and fixing stainless steel (Grade 304), ornamental railing and frame work for moduler kitchen made of hollow tubes, channels, plates etc., including laser cutting, welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including laser cutting and fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts, fasterners with min 100 mm deep on concrete etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc all as specified and as directed.
Material and labour for steel work in tubular semi circular or conical shape trusses including purlin, rafter, special shaped washer etc.,. complete using ERW or induction butt welded tubes fixed by fasteners with min 100 mm deep on concrete or stone wall conforming to I. S.1161-1979 grade St.-240 all as specified and as directed.
Material and labour for 1 mm thick plain, galvanised, mild steel sheeting as in stepped flashings (measured as the minimum rectangle from which the pieces can be cut), welded or soldered joints are provided for conical /sloped shape roof etc all as specified and as directed.
Material and labour roof trusses (framed), trussed, purlins, crane gantries, post, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties etc grade Fe-410-W Quality A fixed by fasterners with min 100 mm deep on concrete or stone wall with Mild steel bolts or welded on existimg MS article etc all as specified and as directed.
Supply and fix pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to wall fixed with self taping screws all as specified and as directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to wall fixed with self taping screws as specified and as directed.
Disconnecting existing water storage tanks of any capacity exc. 1000 ltrs and n.exc. 2000 ltrs capacity setting aside for carrying out necessary roof treatment all as specified and as directed. NOTE :- Necessary arrangement for water supply to occupants shall be done by the contractor till completion of roof repair work with out any extra cost.
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of 15mm dia complete all as directed.
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of 20mm dia complete all as directed.
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of 25mm dia complete all as directed.
Refixing old steel tubing and connections in new or old position in walls, ceiling, floors, etc.of 15mm dia, complete all as directed.
Refixing old steel tubing and connections in new or old position in walls, ceiling, floors, etc.of 20mm dia, complete all as directed.
Refixing old steel tubing and connections in new or old position in walls, ceiling, floors, etc.of 25mm dia, complete all as directed.
Supplying and laying 15mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Supplying and laying 20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Supplying and laying 32mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Material and labour cutting chases, pinning on stone wall in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sun shades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good matching to existing surface, cutting not exceeding 20cm girth complete all as specified and as directed.
Material and labour for Ready Mix Plaster mixed with approved water proofing compound having compressive strength 6-8 Mpa and water absorption max 5 percent with average 20 mm thick for roof top (Roof of G+2) of buildings finished even and smooth as per manufactures instruction including racking, hacking for key and scrubbing down with water etc., complete all as specified and as directed. MAKE :- ACC’s “ACCOPLAST”/ CK Birla’s “AEROCEN” / Magic Plast /Speed Dry Mix’s “ ECO PLASTER”. NOTE :- WPC shall be measured and paid separately.
Spply only integral Water Proofing Compound (WPC) as approved by engineer in charge complete all as directed.
Material and labour water proofing treatment to RCC roof slab.(Roof of G+2), walls, chajja etc, shall be carried out as specified below and as directed by Engineer-in-Charge including taking down old waterproofing treatment and old roof plaster to achieve the original surface of slab :- (a) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 0.70kg/Sqm of area complete all as specified. (b) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.6 kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified and as directed as per manufactures instructions by Engr-in-Charge, carrying out test by flooding water for 24 hrs for leakagge & seepages and rectifying the same to the entire satisfaction of GE. (c) Applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane (d) Finally all outer side of membrene to be sealed by torching with waterproofing seleant surfaces complete all as specifed and as directed by Engr in Charge
Supply and fix rotational moulded polyethylene water storage tanks 2000 ltrs capacity with all connecting accessories ( tripple layer cylindrical vertical with colsed top) hoisted and fixed in postion including and connecting up pipes and ball valve complete set of PTMT, securing access covers all as specified and as directed .
Fixing only rotational moulded polythylene water storage tanks (cylinrical vertical with colsed top) hoisted and fixed in postion including all accessories required to fixing tank all as specified and directed of 2000 ltrs capacity. NOTE: Serviceable Water storage tanks as obtained from Ser item No. 10 here-in-above shall be incorporated.
Supply and fix gun metal globe or gate valves with iron wheel head (ISI marked), screwed both ends for iron pipe and fixed of 20mm dia on stone, concrete, block, slab or wall fixed in repairs complete all as specified and as directed.
Supply and fix gun metal globe or gate valves with iron wheel head (ISI marked), screwed both ends for iron pipe and fixed of 25mm dia on stone, concrete, block, slab or wall fixed in repairs complete all as specified and as directed.
Demolition of stone slab/tiles of any description or thickness laid, bedded and pointed in cement mortar/in floor, skirting, hard standing, Apron etc incl rubbish off outside of MD land complete all as specified and as directed. NOTE :- Demolition of tiles shall be carried out carefully without causing any damage to the structural stability of the buildings.
Dismantling of floor, hearth or wall tilinng including cement mortar bedding (but not backing), removal of rubbish outside of MOD land complete all as specified and as directed. NOTE :- Demolition of tiles shall be carried out carefully without causing any damage to the structural stability of the buildings.
Removal of old building material / concrete beyond the lead included in the rates, including loading, and stacking at the destination to a distance not exc. 5.00 km. (Each load is deemed to be considered as five Cum capacity)
Material and labour for 25mm thick plain cement concrete (1:2:4), type B0 using 12.5mm graded stone aggregates as in levelling course mixed with and including liquid water proofing compound complete all as specified and as directed.
Material and labour for 75mm thick plain cement concrete, (1:4:8), type D2 using 40mm graded stone aggregates as in levelling course complete all as specified and as directed.
Material and labour for coloured joint free homogeneous full body vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant matt finish / anti skid, light shade, 9-10 mm thick (square/ rectangular) area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including wastage on tiles i.e. raking, circular cutting or notching etc complete all as specified and as directed
Material and labour for coloured joint free homogeneous full body vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant matt finish / anti skid, light shade, 9-10 mm thick (square/ rectangular) area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in skirting and wall tiling /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick plaster as in backing coat in CM (1:4) and filleting with CM (1:4) on the top tile including wastage on tiles i.e. raking, circular cutting or notching etc complete all as specified and as directed.
Material and labour for coloured joint free homogeneous glazed vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant PEI III-V (Gloss PEI II-III) dark shade 9-10 mm thick (square/ rectangular) area of each tiles exceeding 0.72 sqm but not exceeding 1.28 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with spacer 3-5 mm thick and grouting with silicon sealant including wastage on tiles i.e. raking, circular cutting or notching etc complete all as specified and as directed
Material and labour for 18 to 20 mm thick granite stone slab of any type and jet black colour (superior quality approved by engineer in charge/GE) of area exc. 0.30 sq.m but n.exc. 1.2 s.qm, machine cut including roughning to back side with approved quality adhesive binder and sand to achive binding, as in skirting/ dado / riser laid over and including 10mm thick plaster in CM (1:4) and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete directed.
Material and labour for coloured joint free homogeneous glazed vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant PEI III-V (Gloss PEI II-III), dark shade, 9-10 mm thick (square/ rectangular) polished area of each tiles exceeding 0.78 sqm but not exceeding 1.28 sqm, as in skirting and wall tiling /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with spacer 3-5 mm thick and grouting with silicon sealant over and including 10 mm thick plaster as in backing coat in CM (1:4) and filleting with CM (1:4) on the top tile including wastage on tiles i.e. raking, circular cutting or notching etc complete all as specified and as directed.
Material and labour for coloured joint free homogeneous full body vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant matt finish / anti skid, dark shade, 9-10 mm thick (square/ rectangular) area of each tiles exceeding 0.72 sqm but not exceeding 1.28 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with spacer 3-5 mm thick and grouting with silicon sealant including wastage on tiles i.e. raking, circular cutting or notching etc complete all as specified and as directed
Material and labour for coloured joint free homogeneous full body vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant matt finish / anti skid, dark shade, 9-10 mm thick (square/ rectangular) area of each tiles exceeding 0.72 sqm but not exceeding 1.28 sqm, as in skirting and wall tiling /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with spacer 3-5 mm thick and grouting with silicon sealant over and including 10 mm thick plaster as in backing coat in CM (1:4) and filleting with CM (1:4) on the top of tile including wastage on tiles i.e. raking, circular cutting or notching etc complete all as specified and as directed.
Material and labour for 18 to 20 mm thick granite stone slab of any type and jet black colour (superior quality approved by Engineer-in-Charge/GE) as in floors with intricate design of area exc. 0.30 sq.m but n.exc. 1.2 sq.m machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including wastage on granite slab i.e. raking, circular cutting or notching etc complete over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed by Engr-inCharge/GE.
Material and labour for 18 to 20 mm thick granite stone slab of any type and jet black colour (superior quality approved by engineer in charge/GE) of size exc 0.30 sqm but n exc 1.2 sqm (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge/GE
Material and labour for coloured joint free non skid /matt finish full body vitrified tiles 10 to 12 mm thick (square/rectangular) area of each tile exceeding 0.3 sq.m but not exceeding 0.5 sq.m,(1500 mm x300 mm size) as in steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour for machine cut Cudapah stone slab 20-25mm thick over and including 15mm thick cement screed base in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Material and labour for machine cut Kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed base in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Material and labour for 15 mm thick screed bed or bedding layer of cement mortar in CM(1:4) for laying floor finishes etc complete all as specified and as directed.
Material and labour for providing edge moulding to 18-20mm thick Kota stone / Granite stone / cudappa stone of counters, vanities with semi circular shape etc. including machine polishing to edge to give high glossy finish complete all as specified and as directed.
Material and labour rolled mild steel of grade Fe-410( E- 250) quality as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, clamps, nut and bolt, fasterners inserted 100 mm deep in concrete or stone wall etc. complete all as specified and as directed.
Supply and fix 0.71 mm thick plain, aluminium alloy sheeting, 31000 H4 as in valley gutter (machine moulded), drip and straight flashing (length and girth as directed), with water proof welded joint complete all as specified and as directed.
Material and labour for cutting holes into or through stone walls built in cement mortar and making good in cement mortar (1:3) or cement concrete (1:2:4), type B0 mixed with and including water proofing compound as required area exc. 150 sq. cm but n.exc. 400 sq.cm all as specified and as directed.
Supply and fix in repairs vitreous china wash down Water Closet pan, pedestal pattern, floor mounted type, coloured, bowl with cistern for coupled WC with UF soft closed slim seat cover, with hinges, dual flush cistern fitting, with all fixing accessories and accessories set, size: 380x655x765 mm, with S trap 250 mm dia all as specified and as directed. MAKE :- Jaquar Cat No. LYS-WHT-38751S250UFSMZ or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix Health Faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and as directed. MAKE :- Jaquar Cat Part No ALD 577 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs wall mixer 3-in-1 system with provision for both hand shower and overhead shower complete with 115mm long bend pipe, connecting legs and wall flange (without hand & over head shower) all as specified and as directed. MAKE :- Cat No. FUS-29281 of Jaquar series or techno commercially equivalent model in makes as per Appendix 'C'.
Material and labour for Towel ring of brass chromium plated, with brass screws and wooden/plastic cleats (minimum weight 90gms) complete all as specified and as directed. MAKE :- Jaquar Cat Part No AQN 7721 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs brass chromium plated Towel rail 24" long including built in side brackets all as specified and as directed. MAKE :- Cat No. 7711 of Jaquar ‘QUEEN'S COLLECTION' Series or techno commercially equivalent model in makes as per Appendix 'C'.
Material and labour for corner sheet glass Shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 30cm x 30 cm long etc., complete all as specified and as directed. MAKE :- Jaquar Cat Part No. ACN1173 or techno commercially equivalent model in makes as per Appendix 'C'.
Material and labour for brass chromium plated soap dish, fixed in repairs complete all as specified and as directed. MAKE :- Jaquar Cat Part No AQN 7731 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs brass chromium plated Hat and coat hooks, solid body, all as specified and as directed. MAKE :- Jaquar Cat part No:- AQN-7706 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs counter top wash basin vanity of size 605 x 455mm with wash basin cabinet size 580 x 451 x 680mm made with material HDHMR including bottle trap, brass waste fitting, mixer tap (excluding mirror cabinet) complete all as specified and as directed. MAKE :- Cat Part : SYDNEY of Somany or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs oval shaped Ivory coloured vitreous china WHB table top, fancy type of overall size 460 x460x 160 mm, including 32 mm dia CP waste coupling, PVC waste pipe etc complete, all as specified and directed. MAKE :- CERA Cat No S2020105 of Ivory or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs chromium plated Pillar cock single lever tall body with 155mm extension, fixed spout without popup waste system with 600mm long braided hoses all as specified and as directed. MAKE :- Jaquar cat No. KUP-35005BPM or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs chromium plated Pillar cock single lever basin mixer without popup waste with 450mm long braided hoses all as specified and as directed. MAKE :- Jaquar Cat No. KUP-35011BPM or techno commercially equivalent model in makes as per Appendix 'C'.
Material and labour for 15mm dia two way Bib taps for washing machine, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to pipe etc complete all as specified and as directed. MAKE : Jaquar Cat Part No. ORM 10041 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs15mm dia bib taps fancy type for washing machine, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to pipe etc complete all as specified and as directed. MAKE :- Jaquar cat No CON-049NKN or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix over head Shower 150 x 150mm square shaped, single flow (ABS body chrome plated with gray face plate) with rubit cleaning system . (minimum weight 40gms) complete all as specified and as directed. MAKE :- Jaquar Cat Part No OHS 35495 or techno commercially equivalent model in makes as per Appendix 'C'
Supply and fix Shower Arm, brass chromium plated, 15 mm size, 450/600 mm long suitable for Jaquar Cat Part No OHS 35495 any colour.(minimum weight 40gms) complete all as specified and as directed. MAKE :- Jaquar Cat Part No. SHA 455L400 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix PVC connections 15mm size with brass nuts of length 600mm long complete all as specified and as directed.
Supply and fix 15mm dia stop valves/ angle cock with wall flange, cast copper alloy, chromium plated, fancy type, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and as directed. MAKE :- Jaquar Cat Part No KUP 35053PM or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs Jet spray with brass chromium plated suitable for fixing to EWC along with 1 Mtr long PVC pipe complete all as specified and as directed. MAKE :- Jaquar ALE547 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix toilet paper holder with flap recessed type, stainless steel body, fixed in repairs complete all as specified and as directed. MAKE :- Jaquar Cat Part No AKP 35755PS or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix stainless steel 0.5 mm thick sheet (SS-304 grade) hindi and english letters,girth of three side not less than 40 mm, length 30 cm, width 30 cm and height not less than 14 inch with ornamental and intricate design fixed on granite/concrete complete all as specified and as directed. NOTE :- Letters shall be fixed for building with height of G+3.
Providing and fixing of granules texture homogeneous wall finishing system consisting of a two component system of dry granules (25 Kg per pack) made of 92% silica particles coated with fade resistant pigments, 100 % acrylic polymer bonding agent (5 Kg per pack) with the thickness of the coating being between 0.8 mm - 1.2 mm on a cured, smooth level plaster as per the shades / combinations approved and as per the directions of the engineer-in-charge, the surface spread of flame class on of BS 476:part 7:1971 and pull off strength of the coating to meet JISA 6909 on smooth plsatered surface complete all as specified and as manufacturers specifications / instructions. NOTE :- Work to be carried out at for buildings at a height up to 20 mtr and the rate quoted shall be deemed to be incuded cost of scaffolding and overheads.
Supply and fix in repairs bottle trap of 32mm dia, PTMT, chromium plated having minimum water seal of 25mm .(minimumweight 32mm dia -260gms) complete all as specified and as directed.
Supply and fix 110mm dia PVC floor trap with stainless steel grating round 140mm size complete all as specified and as directed.
Dismantling of cast iron/RCC pipes of 100mm dia jointed in cement mortor and taking out of trenches if required complete all as specified and as directed.
Dismantling of cast iron/RCC pipes of 75mm dia jointed in cement mortor and taking out of trenches if required complete all as specified and as directed.
Supply and fix PVC (SWR) pipes 110mm dia, type 'B' single socketed, in any length, with rubber ring joints, fixed to walls with PVC clamps complete all as specified and as directed.
Supply and fix PVC (SWR) pipes 75mm dia, type 'B' single socketed, in any length, with rubber ring joints, fixed to walls with PVC clamps complete all as specified and as directed.
Supply and fix PVC (SWR) 110mm dia bends (any radius), diminishing pieces or tapers, larger bore measured all as specified and as directed.
Supply and fix for PVC (SWR) 75mm dia bends (any radius), diminishing pieces or tapers, larger bore measured all as specified and as directed.
Supply and fix PVC (SWR) branch pieces, 110mm dia single Y, equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches all as specified and as directed.
Supply and fix PVC (SWR) branch pieces, 75mm dia single Y, equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches all as specified and as directed.
Supply and fix 110 mm dia PVC cowl, type 'B' all as specified and as directed.
Supply and fix 75 mm dia PVC cowl, type 'B' all as specified and as directed.
Supply and fix SENSOR based vitreous china urinal with sensor including fixing accessories of size 480x300x740 mm complete all as specified and as directed. MAKE :- JaquarCat Part No :URS-WHT-1325S or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fixed in repairs vitreous china urinal with urinal spreader and all fixing accessories, size of 350 mm x 340mm x 500 mm, half stall type, white (excluding flushing cistern, flush pipe and waste pipe complete all as specified and as directed.
Taking down shutters of any description and refixing in the same opening area exc. 1.0 sqm and n.exc. 2.00 sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc. 1.0 sqm and not exc. 2.0 sqm. each all as specified and as directed.
Material and labour for second class hardwood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
Supply and fix 40 mm thick second class hardwood plain framed panelled shutters (ornamental and intricate design) any number of panels with panels of timber flat on both sides of wood particle board with commercial face veeners, the size of rail and stile as per IS : 1003 (Part I) kiln seasoned and chemically pressure treated all as specified and as directed.
Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. NOTE :- MS hold fast/ lugs or SS dash fasteners shall be measured and paid for separately.
Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. NOTE :-Stainless steel butt hinges and necessary SS screws shall be paid separately.
Supply and fix 100mm long butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed complete all as specified and as directed.
Supply and fix 150 mm long heavy duty brass handles (shape and pattern as approved), cast type, polished bright handles, fabricated type complete all as specified and as directed.
Supply and fix heavy duty brass barrel tower bolts, (shape and pattern as approved), with cast or sheet barrel and rolled or cast bolts and fixed 150mm long and 12 mm bore all as specified and directed
Supply and fix in repairs heavy duty brass, sliding door bolt (shape and pattern as approved by GE) with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed of 250mm long and 20 mm bore all as specified and as directed.
Material and labour for plain fillets. square, rectangular or triangular in section area exc. 13 sq.cm & n.exc. 25 sq.cm, clean sawn, secured with nails or brads etc complete all as specified and as directed.
Material and labour for plain fillets. square, rectangular or triangular in section n.exc 3 sq.cm, clean sawn, secured with nails or brads etc., complete all as specified and as directed.
Material and labour for 18 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces with min 7 Nos ply; fixed with brass screws to timber as in TV cabinet frame / cup board work / showcase / works station as per drawing as directed at site etc., complete all as specified and as directed.
Material and labour for 12 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces with min 7 Nos ply; fixed with roller in cupboard, aluminium frame work including all fittings fixture as per drawing at site etc., complete all as specified and as directed.
Material and labour for 150 mm long extruded brass handles, fabricated type polished etc complete all as specified and as directed.
Material and labour for brass locks, as in cupboards, grade I, size 75 mm, brass 4 levers etc complete all as specified and as directed.
Material and labour for auto hinges, zero crank self closing, size 110 mm stainless steel complete all as specified and as directed.
Supply and fix 125 mm brass handles, cast type, polished bright handles, fabricated type complete all as specified and as directed.
Supply and fix brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed 125mm long all as specified and directed.
Supply and fix Megnetic catcher for cabinets all as specified and directed
Supply and fix 20mm bore stainless steel coated curtain rod matt finish weight not less than 1.0 kg/Rm suitable for for cupboard complete all as specified and as directed.
Supply and fix stainless steel (SS-304 ), fancy type (shape / pattern approved by GE) brackets with matt finish heavy duty suitable for 20 mm dia bore curtain rods complete all as specified and as directed.
Supply and fix in repairs for aluminium hat pegs, solid body, 125mm to 175 mm of six fixing on wooden strip (cross section of wooden strip area exc. 10 sq. cm and n.exc. 12 sq.cm is all as specified and as directed.
Supply and fix in repairs sink mixer CP 15mm dia, cast copper alloy with capstan heads, screwed down high pressure with long screwed shanks of and fly nuts complete, screwed for iron pipe complete all as specified and directed. MAKE :- Jaquar Cat No. CON-321 KNB or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
Supply and fix factory made second class hard wood 35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge,with out sash bars, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified and as durected.
Supply and fix in repairs 300 mm long, ordinary rat tail rod pattern springs of mild steel including roller and roller plate complete all as specified and as directed.
Supply and fix perforated cutlery basket of size 530x505x100mm fabricated with purpose made stainless steel of grade 304, weight around 8 Kg per each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed.
Supply and fix stainless steel cup and saucer rack 530x505x100mm fabricated with purpose made stainless steel of grade 304, weight around 8 Kg per each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed.
Supply and fix perforated thali rack of size 530x505x200mm fabricated with purpose made stainless steel of grade 304, weight around 8 Kg per each rack, using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed.
Supply and fix plain basket 710x505x200 mm size fabricated with purpose made stainless steel of grade 304, weight around 8 Kg per each rack , using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed.
Supply and fix pull out 3 shelf fabricated with purpose made stainless steel of grade 304, weight around 8 Kg per each rack using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed.
Supply and fix multipurpose double tier of size 456x170x450 mm, with fabricated purpose made stainless steel of grade 304, weight around 8 Kg per each rack , using square hollow tubes for frame work and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and as directed.
Supply and fix telescopic channels, soft closing, powder coated with ball bearings, suitable for sliding SS plate racks 60 cm long, standard width, fixed over and including 2nd class hard wood rectangular fillet sectional area exc. 3 sq.cm & n.exc. 6 sq.cm, clean swan secured with screws and the fillet fixed on cudappah stone with screws, all as specified and as directed.
Supply and fix stainless steel handle oval shape fabricated type anodized 150mm long of approved design, shape and make with ISI mark embosed on it, fixed in repairs with nut screws & washers complete all as specified and as directed.
Supply and fix stainless steel finish soft closing hinges of approved design, shape and make with ISI mark embosed on it, fixed in repairs with nut screws & washers complete all as specified and as directed.
Supply and fix of 18mm thick marine plywood as per IS 710, laminated of any colour with high glossy acrylic sheet of 3mm thick grade I of frame & shutter for kitchen cabinets complete all specified and as directed.
Material and labour for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-5 and setting in CM (1:6) complete all as specified and as directed.
Rendering 15mm thick in cement mortar (1:6) on brick or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour plain cement concrete (1:2:4) type B0, using 12.5 mm graded stone aggregate as in coping including weathering, slightly rounded and chamferred angle including necessary form work and finishing of exposed surfaces of concrete as described in SSR Part-II complete all as specified and as directed.
Supply and fix 4mm thick figured glass, pin head type and glazing with oil putty in squares n.exc. 0.5 sq. m in each pane fixed to aluminium ventilator shutters etc complete all as specified and directed
Material and labour 12 mm thick prelaminiated particle board (both side laminated) fixed with glazing clips, jointing cleats.rubber gasket, neprene packing, anodised aluminium snap beading screws and complete all as specifed and as directed. NOTE :- Aluminium article shall be measured and paid separately.
Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, chromium plated brass/ stainless steel screws complete as per architectural drawings all as specified and as directed.
Supply and fix 4mm thick sheet glass / glass strip area n.exc. 0.5 sqm ordinary quality and glazing fixed to aluminium and wooden window / ventilator shutters / steel windows with glazing cllips and putty etc all as specified and as directed.
Supply and fix stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.including fillets complete all as specified and as directed.
Material and labour for 10mm thick plaster of paris ceiling (Gypsum anhydrous) in false ceiling including sunk or raised moulding made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joints of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish including necessary supporting hanger with 4.0 mm dia GI wire and 'J' bolts washer nuts for securing frame work to Gl frame work for (605 mm x 605 mm) seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc. 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including thin layer of putty with gypsum binder, sanding the sufrace till smooth surface is obtained and applying two coats of acrylic emulsion distemper of approved tint over a coat of primer complete all as specified and as directed.
Material and labour for decorative POP cornices/ moulding of pattern of cross section area exc 13 sqcm and not exc 25 sqcm complete all as specified and directed.
Material and labour for decorative POP cornices/ moulding of pattern of cross section area not exc 13 sqcm complete all as specified and directed.
Supply and fix 25 mm bore stainless steel (S S -304 ) Curtain rod matt finish weight not less than 1.5 kg/Rm for door and window complete all as specified
Supply and fix stainless steel (SS-304 ) fancy type (shape / pattern as approved by GE) brackets, matt finish, heavy duty suitable for 25 mm bore curtain rod complete all as specified and as directed.
Material and labour finishing with two coats of melamine polish on new wooden surfaces of any description, over 10 cm in width or girth including preparation of surfaces complete all as specified and as directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, haking for key, scrubbing down with water, etc.complete all as specified and as directed. NOTE :- Work to be carried out for buildings at height up to 15 mtr. No extra payment shall be made for scaffolding or overheads.
Material and labour dubbing out average 10mm thick on irregular face of stone walls / concrete ceilling in CM (1:4) complete all as specified and as directed. NOTE :- Work to be carried out for buildings at height up to 15 mtr. No extra payment shall be made for scaffolding or overheads.
Material and labour for rendering 15mm thick in CM (1:4) on concrete surfaces of any description, finished with sponge finish complete all as specified and as directed. NOTE :- Work to be carried out for buildings at height up to 15 mtr. No extra payment shall be made for scaffolding or overheads.
Material and labour for 10mm thick plaster in CM (1:6) on brick surfacesof any description, finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 10mm thick cement plaster for ceilling in CM (1:3) on brick surfaces finished even and smooth without using extra cement. including all neccessary scaffolding up 15 m height of specified of buildings complete all as specified and as directed.
Material and labour for providing and applying wall care putty of 1.5 mm thickness (total thickness 1.5mm in two coats) over plastered surface and prepare the surfaces even and smooth on wall /ceilling complete all as specified and as directed.
Material and labour for preparing newly plastered surfaces and applying two coats of acrylic emulsion distemper of approved tint over a coat of primer on walls complete all as specified and as directed.
Material and labour for new plastered surfaces of wall and finishing the wall surfaces with acrylic smooth exterior paint of required shade(New work or equivalent ) with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm for buildings at height of G+2 complete all as specified and as directed. NOTE :- All painting work, distempering, cement based paint and luster paint catered in BOQ shall be execute at site by authorised applicatiors of makes specified in Appendix 'A'
Material and labour for preparing old plastered surfaces and applying two coats of acrylic emulsion distemper of approved tint on wall over a thin layer of putty to achieve smooth surface complete all as specified and directed
Material and labour for preparing newly plastered surfaces and applying two coats of acrylic emulsion distemper of approved tint over a coat of primer on ceilling surfaces complete all as specified and directed
Material and labour complete removal of existing tratment on wooden surfaces till achieving the original surface of wood including srapping, flaming /torching or by chemical treatment and fill up hole by oil based putty, preparation of old wooden surfaces and applying two coats of melamine polish on surfaces of any description, width or girth including one coat of wooden primer with wood filler transparent liquid complete all as specified and as directed. NOTE :- (i) Resecuring or easing & adjusting of wooden articles / door / window shutter fixing in original position after complete removal of existing treatment with brass mongery shall be included in the quoted rate..(ii) Flaming / torching chemical treatment till achiving original surface of wooden article done by contractor at own cost.
Material and labour for finishing with two coats of melamine polish on old wooden surfaces of any description, over 10 cm in width or girth including preparation of surfaces complete all as specified and as directed.
Material and labour for preparing old plastered surfaces and applying two coats of acrylic emulsion distemper of approved tint on ceilling complete all as specified and as directed
Material and labour for preparation of old treated surface of wall two or more coats of acrylic emulsion distemper with 1st quality (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specifications all as specified and as directed.
Material and labour for preparing of old surface and applying two coats of 100% premium acrylic emulsion paint / luster paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sq.m over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sq.m over new surfaces complete all as specified and as directed. NOTE :- All painting work, distempering, cement based paint and luster paint catered in this BOQ shall be executed at site by authorised applicators of the paint manufacturing companies specified in Appendix 'C'
Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid decorative wall panelling of 5 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw with drawal strength of 1800 N (face) & 900 N (edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixing with supporting wooden batten area exc, 13 & n.exc. 25 sq.cm size and cornice section n.exc. 13 sq.cm (pattern as approved by GE) provided at top and bottom of panelling with necessary full body threaded star headed counter sunk stainless steel screws, all as specified and as directed.
Material and labour for injection grouting with admixture of “GROUT MIX + SBR+OPC” unique formulation, specially developed for the consolidation and strengthening of old stone masonry walls and sunken concrete surface, the grout can be seen as suspension of binder particles in aqueous media that has a considerable fluidity in order to be pumped into voids and cracks within the masonry and sunken concrete by saturation pressure grouting, the treatment comprises of enhancing the impermeability co-efficient of the masonry wall and sunken concrete using “GROUT MIX + SBR + OPC” by Injection grouting system using electrical pressure pumps and power tools, added in a proportion of 500gm “GROUT MIX” and 3 Litrs of SBR to 50kg of ordinary Portland cement (53grade). “GROUT MIX” is a free flowing, non-shrink, high strength cementious grout. with high early and ultimate strength with excellent plastic and restrained expansion characteristics, system shall comprises of drilling holes of 10 / 12 mm dia into the masonry wall and “GROUT MIX + SBR + OPC” is pressure grouted from top. with an injection grouting of every 30cm center to center intervals, finally, the drilled holes are sealed with sealants all as per instructions of manufaturers all as specified and as directed.
Supply and fix rolled mild steel tie bars with screwed ends, nuts, bolt, washers fixed in and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts concrete with HILTHI epoxy grout mortor or equivalent min 100 mm deep anchoring in concrete/stone for extension of existing porch conforming to Fe290 Gde-E-165 all as specified and as directed.
Supply and fix aluminium compostie panel in metalic colour of approved shade, cut to shape required, made out of 3mm thick aluminium composite panel material, comprising of 2.5 mm thick FR grade mineral core sand wiched between two aluminium sheets (each 0.25 mm thick) using stainless steel screws , nuts , bolts, washers, cleats, weather silicon, sealant, brackets rods etc duly fixed for extended porch complete all as specified and as directed.
Material and labour for coloured Glazed digital ceramic tiles as per IS 15622:2017, Group B III, water absorption E>10%, MOH hardness >4 as in verticle surfaces of pattern and highlighter as approved by GE of size 300mm x600mm x 7 to 8mm thick set, jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick plaster in CM (1:4) as a backing coat and filleting with CM (1:4) on the top tile complete all as specified and as directed.
Material and labour for non skid / matt finish full body Vitrified coloured tiles 9 to 10 mm thick of size of each tile of area exc. 0.06 sqm but n.exc. 0.36 sqm as in floors as per IS 15622:2017, Group B III, water absorption 3< E<6%, MOH hardness >4 etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match including wastage on tiles i.e. raking, circular cutting or notching etc laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed by Engr-in-Charge.
Taking down carefully seamless toughned glass partition (without braking of glass) any thickness, remove to store and refixing after flooring work as on original position without braking the glass including jointing with silicone sealeant and stainless steel brackets (Gde 304) and stainless steel tie member (Gde 304) anchoring in concrete slab with 100 mm deep and strengthening to partation etc complete all as specified and as directed. NOTE :- Any glass brocken or damaged at the time of removal or re fixing, the same shall be get it replaced with new glass to match with the existing with out any extra cost.
Material and labour ashlar facing trap stone masonry walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in CM (1:4) and extra over hammer dressed facings, with maximum depression on face from straight edge held against the dressed surface n.exc. 20 mm; to block-in-course ashlar masonry with fine tooled dressed face all as specified and as directed.
Taking down shutters carefully of any description, resecuring or easing, adjusting, including connecting carpentery work and refixing in same opening and in same position with the existing brass mongery to match match area exc. 1.0 sq.m and n.exc. 2.00 sqm each after completation of flooring etc complete all as specified and as directed.
Material and labour for clean swan second class hard wood as in timber scantlings, framed and fixed complete all as specified and as directed.
Material and labour for providing and laying at or near ground level, factory made kerb stone of M-25 grade cement concrete fixed in position to the required line, level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required and providing PCC (1:2:4) type B2 as in foundation with 100mm deep complete all as specified and as directed.
Material and labour for plain cement concrete, (1:4:8), type D2, using 40mm graded stone aggregate as in sub bases 50 mm thick complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint over one coat of primer including preparation of new surfaces of concrete / brick / stone exc. 10 cm in width or girth complete all as specifed and as directed.
Material and labour for 40 mm thick plain cement concrete, type B-1, (1:2:4), using 20mm graded stone aggregate as in sub base of floor complete all as specified and as directed.
Material and labour for pre polished coloured chequered cement concrete tiles 400 x 400 x 25mm or 300 x 300 x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments over and including 20 mm thick screed bed in CM (1:6) as in floors complete all as specified and as directed.
Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in foot parth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
Material and labour for sand filling under floors under paver blocks including watering and consolidation complete all as specified and as directed.
Relaying of paver blocks in patches , including removing and cleaning old paver block preparing beds and laying or setting, jointing new or old paver blocks complete all as specified and as directed. NOTE :- Sand cushioning if required shall be measured and paid separately.
Surface excavation n. exc 30cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and as directed.
Supply, jointing and laying 200mm bore dia sewer line double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8(conforming to IS 16098(Part 2) :2013), spigot and socket ended pipe with base of 150mm thick PCC (1:3:6), type C2, using 40mm graded stone aggregate including jointing with rubber gasket, by jointing jack method and making connection to old or new manholes including dismantling and making good the manhole wall, filling and compaction of trenches with appropriate materials etc and duly tested the pipe line as per manufacturers instructions after laying of pipe line complete all as specified and as directed. NOTE :- Excavation and earth work shalll be measured and paid separately.
Supply, jointing and laying 150mm bore dia sewer line double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8(conforming to IS 16098(Part 2) :2013), spigot and socket ended pipe with base of 150mm thick PCC (1:3:6), type C2, using 40mm graded stone aggregate including jointing with rubber gasket, by jointing jack method and making connection to old or new manholes including dismantling and making good the manhole wall, filling and compaction of trenches with appropriate materials etc and duly tested the pipe line as per manufacturers instructions after laying of pipe line complete all as specified and as directed. NOTE :- Excavation and earth work shalll be measured and paid separately.
Material and labour for plain cement concrete, (1:4:8), type D2, using 40mm graded stone aggregate as in bed to 150 mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; all as specified and as directed.
Material and labour for plain cement concrete, (1:4:8), type D2, using 40mm graded stone aggregate as in bed to 200 mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4), type B-l smooth finished, and reforming benching as required etc all as specified and all as directed.
Material and labour for pre cast cement concrete block masonry with solid blocks type C-1 (1:3:6), exc. 10 cm in width and setting in CM (1:4) all as specified and as directed.
Material and labour for cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting width not exc. 10 cm girth all as specified and as directed.
Excavation in trenches, n.exc 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc., n.exc. 10 sqm on plan and n.exc. 1.5 mtr in depth and getting out in hard / dense complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and directed by Engineer-in-Charge
Removing excavated material to a distance exc. 50 mtr but n.exc. 150 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and as directed.
Demolition of cement concrete in ground floor as in pavings n.exc. 15 cm thickness (below or above ground level) including removal of rubbish off outside of MD land complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes, drain and wall compound etc., and getting out in in soft / loose soil complete all as specified and as directed.
Material and labour for plain cement concrete, (1:4:8), type D2 using 40mm graded stone aggregates as in foundations, filling in mass concrete etc., complete all as specified and as directed.
Material and labour for brickwork with fly ash bricks, straight or curved on plan exc. 6 mtr mean radius, built in CM (1:6) complete all as specified and as directed.
Material and labour for plain cement concrete, (1:2:4), type B1, using 20 mm stone graded aggregate as in benching to man holes and coping etc., complete all as specifed and as directed.
Rendering 15mm thick in cement mortar (1:4) on brick surfaces finished even smooth with spong finish duly mixed with integral water proofing compound as per manufacturers instrucitons, complete all as specifed and as directed. NOTE :- WPC shall be measured and paid separately.
Supply only integral Liquid Water Proofing Compound all as specified and as directed.
Material and labour for plain cement concrete, (1:2:4), type B1, using 20mm graded stone aggregate as in surface channels and drains including all moulds and forms all as specified and as directed.
Material and labour for extra for forming, fair finished drain or channel inner girth n.exc. 30 cm in cement concrete using extra cement including forms, moulds, mitred / stopped ends etc., complete all as specified and as directed.
Supply and fix rolled mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Supply and fix in repairs, heavy duty SFRC (Steel Fibre Reinforced Concrete) Manhole cover slabs of size 600mm x 900mm x 100mm thick set in cement mortar (1:4) complete all as specified and as directed.
Material and labour for preparation of new untreated steel or iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified all as directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping screws etc and making good the disturbed surfaces all as specified and as directed.
Material and labour for point wiring complete with 1.5 sq.mm (nominal area) confirming to IS:3419-1988 PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic rigid PVC conduit, ISI marked, not less than 20 mm dia, thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes and modular cover plates suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq.mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts as required at site including cutting chiselling on wall,roof as per site requirement and also making good surfaces and matching with the existing surface for the following:- (a) One light /fan point controlled by one switch one way.
(b) One 3 pin socket outlet, 5/6 Amps on independent board.
(c) One 3 pin socket outlet, 5/6 Amps on the same board with other switches.
(d) One bell/ buzzer point controlled by one push button on independent board.
(e) One light point controlled by two two way switches on independent board.
Material and labour point wiring complete with 2.5 sq.mm (nominal area) confirming to IS:3419-1988 PVC insulated, PVC unsheathed, multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic rigid PVC conduit, ISI marked, not less than 20 mm dia, thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes and modular plates suitable for mounting switches, sockets etc and including PVC insulated, unsheathed multistranded single core copper conductor cable of size 2.5 sq.mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts as required at site including cutting chiselling on wall, roof as per site requirement and making good surfaces and matching with the existing surface complete all as specified and as directed.
Supply and fix modular switch 1 way 10 Amps, 1 module, complete all as specified and as directed. MAKE :-Roma Cat Part No 289101 or equivalent in Havells Cat Part No AHOSXXW101 or Crabtree Cat Part No ACASXXE101 or LEGRAND Cat Part No. 673000
Supply and fix modular switch 1 way 16 Amps, 1 module with neon indicators complete all as specified and as directed. MAKE :- Roma Cat Part No 289163 or equivalent in Havells Cat Part No AHOSXIW161 or Crabtree Cat Part No ACNSXIA161 or Legrand Cat Part No. 6730 10
Supply and fix modular switch 2 way 10 Amps, 1 Module, complete all as specified and as directed.
Supply and fix modular bell push 6 Amps, 1 module, complete all as specified and as directed.
Supply and fix modular socket, 6 Amps - 2/3 pin,2 module complete all as specified and as directed. MAKE :- Roma Cat Part No 289323 or equivalent in Havells Cat Part No AHOKPXW063 or Crabtree Cat Part No ACAKPXW063 or Legrand Cat Part No. 6730 44
Supply and fix modular socket 6/16 Amps, 2/3 Pin, 2 module. complete all as specified and as directed. MAKE :- Roma Cat Part No 289368 or equivalent in Havells Cat Part No AHOKPXW163 or Crabtree Cat Part No ACAKCXW163 or Legrand Cat part No 6730 83
Supply and fix modular fan regulator 120 Watt, 240 volts, 2 module, suitable for ceiling fan of 1200/1400mm sweep complete all as specified and as directed.
Supply and fix electric bell ding dong type AC, 230 volts single phase complete all as specified and as directed.
Supply and fix ceiling rose surface shall comply with IS :371-1979, surface bakelite 60x 25 mm ,two to three terminals plates and of outside diameter not less than 63.5mm complete all as specified and as directed.
Supply and fix RJ-11 telephone socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module complete all as specified and as directed. MAKE :- Roma Cat Part No 289611 or equivalent in Havells Cat Part No AHOKROW111 or Crabtree Cat Part No ACAKTOW000 or Legrand Cat part No 6730 52
Supply and fix LAN socket UTP Cat with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module complete all as specified and as directed. MAKE :- Roma Cat Part No 289685 or equivalent in Havells Cat Part No AHOKJWW451 or Crabtree Cat Part No ACAKJWW451 or Legrand Cat part No 6730 55
Supply and fix TV socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module complete all as specified and as directed. MAKE :- Roma Cat Part No 289677 or equivalent in Havells Cat Part No AHOKTOW061 or Crabtree Cat Part No ACAKTOW000 or Legrand Cat part No 6730 50
Supply, lay and terminating of four runs of 0.61 mm dia (2 pair) PVC insulated copper conductor wire including heavy duty non metalic rigid PVC conduit, ISI marked, not less than 20 mm dia, thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings from tag block to telephone outlet complete as required at site including making good surfaces and matching with the existing surface all as specified and as directed
Supply and drawing including termination of RG-11 cable suitable for TV including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia, thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings complete as required at site including making good surfaces and matching with the existing surface all as specified and as directed.
Supply and lay of Cat 6-4 pair, 23 AWG, UTP cable with cross member pair spearator including heavy duty non metalic rigid PVC conduit of suitable size, ISI marked, not less than 20 mm dia, thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings complete as required at site including making good surfaces and matching with the existing surface all as specified and as directed.
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete all as specified and as directed.
Material and labour for sub main wiring with PVC insulated FRLSH grade cable LT 1100 volts grade, 2 x 2.5 sq.mm with one continuous earth wire of 2.5 sq.mm, PVC insulated, unsheathed, multistranded with stranded copper conductor drawn through and including heavy duty non metallic PVC conduit ISI marked not less than 20mm dia of thickness 1.8mm concealed in any type of wall, roof, etc, with all connected fittings with all standard accessories and making good to match with the existing surfaces after completion along with one continuous earthwire and connected to the common earth doly complete all as specified and as directed . NOTE :- Two runs of 2.5 sq.mm and one run of 2.5 sq.mm earth wire and one run of PVC conduit pipe with elbow, bends etc will be measured as one unit length for payment purpose.
Material and labour for sub main wiring with PVC insulated FRLSH grade cable LT 1100 volts grade, 2 x 4.0 sq.mm with one continuous earth wire of 4.0 sq.mm, PVC insulated, unsheathed, multistranded with stranded copper conductor drawn through and including heavy duty non metallic PVC conduit ISI marked not less than 20mm dia of thickness 1.8mm concealed in any type of wall, roof, etc, with all connected fittings with all standard accessories and making good to match with the existing surfaces after completion along with one continuous earthwire and connected to the common earth doly complete all as specified and as directed . NOTE :- Two runs of 4.0 sq.mm and one run of 4.0 sq.mm earth wire and one run of PVC conduit pipe with elbow, bends etc will be measured as one unit length for payment purpose.
Material and labour for sub main wiring with PVC insulated FRLSH grade cable LT 1100 volts grade, 2 x 6.0 sq.mm with one continuous earth wire of 6.0 sq.mm, PVC insulated, unsheathed, multistranded with stranded copper conductor drawn through and including heavy duty non metallic PVC conduit ISI marked not less than 25mm dia of thickness 1.8mm concealed in any type of wall, roof, etc, with all connected fittings with all standard accessories and making good to match with the existing surfaces after completion along with one continuous earthwire and connected to the common earth doly complete all as specified and as directed . NOTE :- Two runs of 6.0 sq.mm and one run of 6.0 sq.mm earth wire and one run of PVC conduit pipe with elbow, bends etc will be measured as one unit length for payment purpose.
Material and labour for sub main wiring with PVC insulated FRLSH grade cable LT 1100 volts grade, 4 x 16.0 sq.mm with one continuous earth wire of 16.0 sq.mm, PVC insulated, unsheathed, multistranded with stranded copper conductor drawn through and including heavy duty non metallic PVC conduit ISI marked not less than 40mm dia of thickness 1.8mm concealed in any type of wall, roof, etc, with all connected fittings with all standard accessories and making good to match with the existing surfaces after completion along with one continuous earthwire and connected to the common earth doly complete all as specified and as directed . NOTE :- Four runs of 16.0 sq.mm and one run of 16.0 sq.mm earth wire and one run of PVC conduit pipe with elbow, bends etc will be measured as one unit length for payment purpose.
Material and labour for sub main wiring with PVC insulated FRLSH grade cable LT 1100 volts grade, 4 x 25.0 sq.mm with one continuous earth wire of 25.0 sq.mm, PVC insulated, unsheathed, multistranded with stranded copper conductor drawn through and including heavy duty non metallic PVC conduit ISI marked not less than 40mm dia of thickness 1.8mm concealed in any type of wall, roof, etc, with all connected fittings with all standard accessories and making good to match with the existing surfaces after completion along with one continuous earthwire and connected to the common earth doly complete all as specified and as directed . NOTE :- Four runs of 25.0 sq.mm and one run of 25.0 sq.mm earth wire and one run of PVC conduit pipe with elbow, bends etc will be measured as one unit length for payment purpose.
Material and labour for sub main wiring with PVC insulated FRLSH grade cable LT 1100 volts grade, 4 x 35.0 sq.mm with one continuous earth wire of 35.0 sq.mm, PVC insulated, unsheathed, multistranded with stranded copper conductor drawn through and including heavy duty non metallic PVC conduit ISI marked not less than 50mm dia of thickness 1.8mm concealed in any type of wall, roof, etc, with all connected fittings with all standard accessories and making good to match with the existing surfaces after completion along with one continuous earthwire and connected to the common earth doly complete all as specified and as directed . NOTE :- Four runs of 35.0 sq.mm and one run of 35.0 sq.mm earth wire and one run of PVC conduit pipe with elbow, bends etc will be measured as one unit length for payment purpose.
Supply and fix in replacement of LED light fittings 20 Watt, 220V, AC, 4 feet tube light fitting extruded polycarbonate housing and robust construction, LED lighting with high lumen output environmental friendly energy efficient CRI-6500K PF not less than 0.95 fixed on PVC square for mounting the fitting & electrically connecting with three core 23/0.0076 PVC insulated multi stranded copper flexible cable from ceiling rose to light fitting and for earthing complete all as specified and as directed. MAKE :- Havells Model LHEXBLP7PN1W020 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in replacement of 18watt, 230 volts, surface and wall mounted, motion sensor LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and as directed.
Supply and fix in replacement of surface mounted 9/10 Watt, 220 volts, AC, 2 feet tube light fitting, extruded polycarbonate housing and robust construction LED lighting with high lumen output environmental friendly energy efficient CRI-6500K PF not less than 0.95 fixed on PVC square for mounting the fitting and electrically connecting with three core 23/0.0076 PVC insulated multi strand copper flexible cable from ceiling rose to light fitting and for earthing complete all as specified and directed. MAKe :- Havells Model LHEXBLP7PN1W009 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix in replacement honour board LED (warm white) fitting of 1x12 Watt, individual LED lenses, chorme coloured with twin core flexible wire of size 1.0 sq.mm complete all as specified and as directed.
Supply and fix in replacement of surafce mounting brushed nickel fixture suitable for B 22 base bulb including 01x09 W LED bulb (warm white) and connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and as directed.
Supply and fix in replacement of suspended LED light with high efficiency providing soft-light and glare free symmetrical illumination including suspension kit upto 1 meter suitable for E-27 base bulb including 01x09 Watt, including LED bulb (warm white) connecting up with twin core twisted flexible copper cable to fitting complete all as specified and as directed.
Supply and fix in replacement of 1x10 watt, 230 volts, surface mounted LED downlight with white powder coated polycarbonate housing and pressure die-cast heat shink, having high efficiency, including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and as directed.
Supply and fix in replacement of recess type LED ceiling lights, 18/ 20 Watt LED with ceiling cut out of 160mm Ø, environmental friendly, energy saving, recess mounted downlighter with separate replaceable electronic driver including connecting with twin core wire, cutting the existing false ceiling to the required size, shape and also matching to the adjacent false ceiling surfaces carefully all as specified and as directed. NOTE :- Havells Cat Part No EDGEPRONEORDDLR18WLED857S or equivalent in Crompton Cat Part No CDR-206-18-57-SL-NWH or Wipro Cat Part No LD90-231-XXX-65-XX
Supply and fix in replacement of recess mounted 2' x 2' LED panel lights 36/ 40 Watt, LED 5700K, 240 volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. NOTE :- The quoted price shall include the cost of light and its driver. MAKE :- Havells Cat Part No VENUSNEO2X2PLR36WLED857G2 or equivalent in Crompton Cat Part No LCTLRNE-36-FO-CDL or Wipro Cat Part No CRCO10R038SP57G1L1
Supply and fix in replacement of environment friendly, energy efficient, aesthetically designed, surface moulded body, oudoor wall light, updown LED 2 x 3 Watt, warm white in colour and rating of IP-54 including connecting up with twin core twisted flexible copper cable to fitting all as specified and as directed.
Supply and fixing in replacement of ceiling fan complete with blades, down rods with suitable size and other accessories, 230 volts, 1200 mm sweep with minimum air delivery of 210 CMM, BEE five star rated with brushless direct current motor (BLDC), white in colour complete with down rod and GI hook with welding work, wire connections from ceiling rose to ceiling fans, with complete accessories including writing of MES No with unit name on ceiling fans using approved stencil with synthetic enamal paint complete all as specified and as directed. NOTE :- Old ceiling fan shall be deposited in MES store. MAKE :- Usha Cat Part TECHNIX BLDC or equivalent in Havells Cat Part EFFICIENCIA PRIME BLDC or Orient Cat Part HECTOR500
Supply and fixing in replacement of plastic body exhaust fan, AC, single phase, 240 volts, size 200 mm sweep complete with accessories including writing of MES No with unit name on exhaust fans using approved stencil with synthetic enamal paint complete all as specified and as directed. NOTE :- Old exhaust fan shall be deposited in MES store. NOTE :- Usha Cat Part CRISPAIR VX or equivalent in Havells Cat Part Ventil Air DXHS White or Orient Cat Part 200mm Ventilator HS(P B) WHITE
Supply and fix in replacement of metal body exhaust fan, AC, single phase, 240 volts, size 450 mm sweep with louvers complete with accessories including writing of MES No with unit name on exhaust fans using approved stencil with synthetic enamal paint complete all as specified and as directed. NOTE :- Separate louvers of suitable size shall be provided, the cost of the same is deemed to be included and old exhaust fan shall be deposited in MES store. NOTE :- Usha Cat Part TURBOHD EF or equivalent in Havells Cat Part Turboforce 1P or Orient Cat Part 450mm Heavy duty exh
Disconnecting electric connection and taking down carefully wall mounted fan of 400 mm sweep, removing the burnt winding of fan motor, rewinding with super enamelled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and reflxing to original position complete all as specified and as directed.
Supply and fix vertical stationary type electric water heater closed / vented type, inner body made up of stainless steel and outer body madeup of rust free ABS with capacity 25 Litres suitable for 230 volts , single phase, AC, 50 Hz, with BEE star (5 star rating) complete with seven years warranty on tank and two year warranty on geyser including grouting with nut, bolts/fastners of suitable size, including set of GI mesh, flexible hot and cold pipe with 600mm length and one no of brass NRV of suitable size complete all as specified and as directed. NOTE :- Quoted rate shall be deemed to be included the cost of Geyser and set of GI mesh felxible hot and cold pipe and 1x NRV. MAKE :- Usha Cat Part AQUASWIRL25 L WHITE GREY NEW or equivalent in Havells Cat Part BIANCA or Racold Cat Part Andris Lux plus
Taking down the Geyser of any size/capacity carefully after disconnecting and making good the disturbed surface including metallic flexible hot water connection 600 mm long all as specified and directed by Engr-in-charge and deposited in MES store
Supply and fix in replacement of sheet metal enclosures with single pole MCB 20 Amps & 240 volts with a two pin and earth plug and socket complete with all accessories etc all as specified and as directed.
Supply and fix in replacement of factory made epoxy powder coated distribution board TP & N, 4 way, double door (VTPN MCCB DB), MCCB as in comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall, suitable for universal mounting, including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall, making good disturbed surface, touch up with the same finishes including cutting and chiselling on wall and make good with existing surface complete all as specified and as directed. NOTE :- MCBs/ MCCBs will be measured and paid seperately under respective items of the BOQ.
Supply and fix in replacement factory made epoxy powder coated Distribution Board TP & N 8 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes including cutting and chiselling on wall and make good with existing surface complete all as specified (Make/Model of VTPN DB : Legrand/L&T/C&S) Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule
Supply and fix in replacement of MCB DB 12 way, SPN, double door, sheet metal enclosure, factory made suitable for MCB DB's 240 volts with 200 Amps rated busbar, neutral and earthing link bar, surface mounting complete including taking down the existing DBs of any type and size alongwith its accessories by removing from existing circuits and fixing the new DBs, circuits, cutting and chiselling on wall and making good the existing surfaces to match with complete all as specified and as directed. NOTE :- MCBs will be measured and paid separately under respective items of BOQ.
Supply and fix in replacement of MCCB with rating of 100 Amps, 415 volts, three pole with 16 KA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 and the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu), MCCB should be with suitable spreaders and phase barriers for each terminals all as specified and as directed.
Supply and fix in replacement of MCCB with rating of 63 Amps, 415 volts, three pole with 16KA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 and the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu), MCCB should be with suitable spreaders and phase barriers for each terminals all as specified and as directed.
Supply and fix in replacement of MCCB with rating of 40 Amps, 415 volts, three pole with 16KA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 and the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu), MCCB should be with suitable spreaders and phase barriers for each terminals all as specified and as directed.
Supply and fix in repalcement of MCB SP 6-32 Amps, 240 volts,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and as directed.
Supply and fix in repalcement of MCB SP 40 Amps 240 volts,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and as directed.
Supply and fixin repalcement of MCB SPN 40 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing. Make: Legrand/L&T/Havells
Supply and fixin repalcement of MCB TP 100 Amps 415 volts,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and as directed.
Supply and fix in replacement of MCB TP 63 Amps 415 volts,10 KA breaking capacity, C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and as directed.
Supply and fix in replacement of sheet metal enclosure single pole MCB 40 Amps with a two pin and earth plug and socket complete including cutting chiselling and make good with existing surface with all accessories all as specified and as directed.
Supply and fix in replacement of electrical meter box compartmentalized design suitable for 4 energy meters, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet for outer section and 1.6mm thick for doors and inner partitions, powder coated in siemens grey colour, double door, the enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakellite sheet for mounting the energy meters and MCB DB, the enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables / wires, the overall size of the meter box shall not be less than 1200 x 1200 x 300 mm size complete with all accessories prewired twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and laying in trenches including, fixing on walls, floors with suitable size of GI clamps, nuts, bolts and washers etc of LT XLPE cable, PVC Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with multi-stranded aluminium conductor of size 4 core 6 sq.mm complete all as specified and as directed.
Supply and laying in trenches including, fixing on walls, floors with suitable size of GI clamps, nuts, bolts and washers etc of LT XLPE cable, PVC Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with multi-stranded aluminium conductor of size 4 core 16 sq.mm complete all as specified and as directed.
Supply and laying in trenches including, fixing on walls, floors with suitable size of GI clamps, nuts, bolts and washers etc of LT XLPE cable, PVC Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with multi-stranded aluminium conductor of size 3.5 core 25 sq.mm complete all as specified and as directed.
Supply and laying in trenches including, fixing on walls, floors with suitable size of GI clamps, nuts, bolts and washers etc of LT XLPE cable, PVC Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with multi-stranded aluminium conductor of size 3.5 core 150 sq.mm complete all as specified and as directed.
Supply and laying in trenches including, fixing on walls, floors with suitable size of GI clamps, nuts, bolts and washers etc of LT XLPE cable, PVC Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with multi-stranded aluminium conductor of size 3.5 core 120 sq.mm complete all as specified and as directed.
Supply and laying in trenches including, fixing on walls, floors with suitable size of GI clamps, nuts, bolts and washers etc of LT XLPE cable, PVC Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with multi-stranded aluminium conductor of size 3.5 core 240 sq.mm complete all as specified and as directed. NOTE FOR SL ITEM NO. 255 to 260 : - Excavation / earthwork, bricks, cable cover and sand cushioning will be measured and paid separately under respective items of BOQ.
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting point complete all specified and as directed.
Material and labour for sand cushioning for UG cables using dry river sand, gently punning down all as specified and as directed. NOTE :- For measurement purpose punned thickness shall be considered.
Material and labour unreinforced precast concrete cable covers class LV, type II, flat of size 300 x 180 x 40 mm laid transverse to cable all as specified and as directed.
Taking out old unserviceable LT XLPE cables Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core.
Taking out old unserviceable LT XLPE cables Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size up to 16 sq mm 4 core.
Taking out old unserviceable LT XLPE cables Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core.
Supply, installation, testing and commissioning LT panel, weather proof, outdoor type, double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032, Siemens grey shade with matt finish with seven tank pre treatment process, the panel shall be fabricated by CPRI approved manufacturer only, the panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side openable double door type with locking arrangement for front side and back side also, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel, the panel shall be provided with four strip of aluminium bus bars, electrolytic grade of 600 Amps current rating, the busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding, the bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment, the panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured, all joints and cable connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including lugs etc., the panel shall be provided with digital multifunction meter 4410 series, accuracy Class 1 with RS 485 parameters with cast resign CTs and RYB, ON, OFF & trip LED indicating lamps at incoming, the panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc., the panel shall be provided with 4 Nos 50x50x5mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement , all MCCBs shall be provided with spreader links with phase separators on both sides contd to Serial item No. 268..
Contd from Serial item No. 267.. and suitable extended rotary handles for all incoming and outgoing MCCBs ,the overall size of the panel shall not less than 1500mmX600mmX1200mm (LxDxH), the panel shall be provided with cable entry from bottom side for 4 No of cable, size upto 240 sq.mm with suitable size of SS cable glands including 2 Nos of earthing terminals one on each side with continuous GI earth strip of the panel including following accessories:- NOTE :- Before manufacturing, drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge.(a) ON LOAD change over switch four pole with advance Neutral 315 Amps current rating manual changeover front side handle operated conforming to IS 13947 (Part-3) including RYB LED Indication Lamp for both incoming cables. (b) MCCB, 4 Pole 320 Amp, 36 KA Conforms to IS/IEC 60947-3, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separater etc. (Incoming) - 01 No (c) MCCB, 4 Pole 200 Amp, 25 KA Conforms to IS/IEC 60947-3, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separater etc. (outgoing) - 01 No (d) MCCB 4 Pole, 415 Volts, 63 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 04 No. (e) MCCB 4 Pole, 415 Volts, 40 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 02 No. (f) Isolator 4 pole 40 Amps with adjustable setting -02 Nos (outgoing )
Supply, installation, testing and commissioning LT panel, weather proof, outdoor type, double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032, Siemens grey shade with matt finish with seven tank pre treatment process, the panel shall be fabricated by CPRI approved manufacturer only, the panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side openable double door type with locking arrangement for front side and back side also, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both sides of panel, the panel shall be provided with four strip of aluminium bus bars, electrolytic grade of 300 Amps current rating, the busbars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding, the bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment, the panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured, all joints and cable connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc., the panel shall be provided with digital multifunction meter 4410 series, accuracy Class 1 with RS 485 parameters with cast resign CTs and RYB, ON, OFF & trip LED indicating lamps at incoming, the panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc., the panel shall be provided 4 Nos 50x50x5mm size angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement, all MCCBs shall be provided with spreader links with phase separators on both sides contd to Serial item No. 270..
Contd from Serial item No. 269.. and suitable extended rotary handles for all incoming and outgoing MCCBs, the overall size of the panel shall not be less than 1200mmX600mmX1200mm (LxDxH), the panel shall be provided for cable entry from bottom side for 4 No of cable, size upto 150 sq.mm with suitable size of SS cable glands including 2 Nos of earthing terminals one on each side with continuous GI earth strip of the panel including following accessories:- NOTE :- Before manufacturing, drawing and design of panel including size and length of busbar shall be approved by Engr-in-charge. (a) MCCB, 4 Pole 200 Amp, 36 KA Conforms to IS/IEC 60947-3, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separater etc. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 63 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 04 No. (c) MCCB 4 Pole, 415 Volts, 40 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 01 No. (d) Isolator 4 pole 40 Amps with adjustable setting -02 Nos (outgoing )
Supply, installation, testing and commissioning LT panel, weather proof, outdoor type, double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032, Siemens grey shade with matt finish with seven tank pre treatment process, the panel shall be fabricated by CPRI approved manufacturer only, the panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side openable double door type with locking arrangement for front side and back side also, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel, the panel shall be provided with four strip of aluminium bus bars, electrolytic grade of 400 Amps current rating, the busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding, the bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment, the panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured, all joints and cable connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc., the panel shall be provided with digital multifunction meter 4410 Series, accuracy Class 1 with RS 485 parameters with cast resign CTs and RYB, ON, OFF & trip LED indicating lamps at incoming, the panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc., the panel shall be provided with 4 Nos 50x50x5mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement, all MCCBs shall be provided with spreader links with phase separators on both sided contd to Serial item No. 272..
Contd from Serial item No. 271.. and suitable extended rotary handles for all incoming and outgoing MCCBs, the overall size of the panel shall not be less than 1200mmX600mmX1200mm (LxDxH), the panel shall be provided for cable entry from bottom side for 4 No of cable, size upto 300 sq.mm with suitable size of SS cable glands including 2 Nos of earthing terminals one on each side with continuous GI earth strip of the panel including following accessories:- NOTE :- Before manufacturing, drawing and design of panel including size and length of busbar shall be approved by Engr-in-charge. (a) MCCB, 4 Pole 250 Amps, 36 KA Conforms to IS/IEC 60947-3, Ics = 100% Icu suitable for Isolation, adjustable over load setting : 0.8-1.0 x In with both side of spreader links and phase separater etc. (incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 100 Amp with Thermal Magnetic release, 25 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 01 No. (c) MCCB 4 Pole, 415 Volts, 63 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 07 No. (d) Isolator 4 pole 40 Amps with adjustable setting -02 Nos (outgoing )
Supply, installation, testing and commissioning LT panel, weather proof, outdoor type, double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032, Siemens grey shade with matt finish with seven tank pre treatment process, the panel shall be fabricated by CPRI approved manufacturer only, the panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side openable double door type with locking arrangement for front side and back side also, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel, the panel shall be provided with four strip of aluminium bus bars, electrolytic grade of 500 Amps current rating, the busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding, the bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment, the panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured, all joints and cable connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including lugs etc., the panel shall be provided with digital multifunction meter 4410 series, accuracy Class 1 with RS 485 parameters with cast Resign CTs and RYB, ON, OFF & trip LED indicating lamps at incoming, the panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc., the panel shall be provided with 4 Nos of 50x50x5mm size angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive contd to Serial item No. 274..
Contd from Serial item No. 273.. black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement, all MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for all incoming and outgoing MCCBs, the overall size of the panel shall not be less than 1200mmX600mmX1200mm (LxDxH), the panel shall be provided for cable entry from bottom side for 4 No of cable, size upto 300 sq.mm with suitable size of SS cable glands including 2 Nos of earthing terminals one on each side with continuous GI earth strip of the panel including following accessories:- NOTE :- Before manufacturing, drawing and design of panel including size and length of busbar shall be approved by Engr-in-charge. (a) MCCB, 4 Pole 320 Amps, 36 KA Conforms to IS/IEC 60947-3, Ics = 100% Icu suitable for isolation, adjustable overload setting : 0.8-1.0 x In with both side of spreader links and phase separater etc. (incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 100 Amp with Thermal Magnetic release, 25 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 01 No. (c) MCCB 4 Pole, 415 Volts, 63 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 07 No. (d) Isolator 4 pole 40 Amps with adjustable setting -02 Nos (outgoing )
Supply and fix in replacement of LED flood light 250 Watt 230 volts, AC, outdoor type with thermal management in multiple optics and equiped with IP-66 protection, with impact and corrossion resistant complete with driver and lamp including fixing arrangements on top of building complete all as specified and as directed. MAKE :- Wipro Cat Part LF30-272-060-57-XX or equivalent in Crompton Cat Part CFS-506-250-57-60D-SL-GL-NSG or Havells Cat Part JETAIRIS MAXFL 250W LED757 PWB LTG
Supply and fix of LED bollard 10 Watt warm white lights of 1 mtr height in garden including necessary foundation work for installation and its connected accessories complete all as specified and as directed. MAKE :- Wipro Cat Part LB14-131-XXX-65-05 or equivalent in Crompton Cat Part LBLSN-10-WW or Havells Cat Part TURINBLS10WLED830PSYMTOPC
Material and labour for cutting of existing road/ hard standing as in chequered tiles /Road /PCC / bitumen surfaces by providing suitable T&P to make suitable for laying and crossing of 100 mm dia bore of GI pipe including make good the disturbed surface and matching with existing one complete all as specified and as directed.
Supply and fix galvanised iron tubing, light grade, 100 mm dia, ISI marked with all fittings laid in trenches and fixed to pole by flat iron clamps, nut, bolt, washers of suitable size all as specified and as directed.
Material and labour for straight through joint (epoxy) for LT upto 240 sq.mm cable 1100 volts grade, aluminum conductor including jointing kits, aluminium ferrules for making joints and testing complete all as specified and as directed.
Supply and laying synthetic rubber insulated mats of 2.5 mm thick for voltage upto 11 KV of size 2 mtr x1 mtr all as specified and as directed.
Supply and fixing of the approach path decorative lights with 3 mtr decorative casting poles aesthetically designed and decorative arms with LED post top light 72 Watt with IP-66 aluminium enclosure, powered with high power LEDs as light source and die casted heat shink exhibiting classic victorian look with symmetrical light distribution, suspended mounting arrangements and excellent heat dissipation for long life including necessary foundation work with PCC(1:2:4) complete all as specified and as directed. MAKE :- Havells Cat part No. of pole EROSPOLET02030M with orbit plus S round arm for pole and cat part No. of EROS LED Post top light EROSPT72WLED730PSYMTOPC or techno commercially equivalent model in makes as per Appendix 'C'.
Material and labour for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level in any type of soil strata, connected to galvanized iron earth strip 25x4 mm as earthing lead by means of bolts, nuts and washers of galvanised iron or steel all as shown in earthing plate No 3 of MES schedule 2009 Part – I connected to change over switch panel including necessary excavation and earth work, concrete pit & chamber, pit cover made of PCC (1:2:4) type B1 with lifting handle and earth lead and 20mm dia GI watering pipe medium grade and 40mm dia GI pipe for protection to earth strip, funnel, wire mesh, etc. complete all as specified and as directed. NOTE :- GI strip exceeding 7.5 mtr long shall be measured and paid seperately.
Material and labour for galvanised iron strip of size 25 x 4 mm with saddles and fixing screws etc., for roof/down conductor above ground including jointing with rivets, bolts, nuts, washers etc all as specified and as directed.
Supply and laying 50 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e, coupler,Tee, elbows, clamps for cable protection complete all as specified and as directed.
Supply and fix digital timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps, three Pole MCB, power contactor and 230 volts digital timer switch for controlling LED / SV street lights, including earth work for fixing timer switch distribution board and shall be provided with 4 Nos of 35x35x4mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement all as specified and as directed.
Supply and fix sintex box thermo plast (weather proof) IP-66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable complete all as specified and as directed. MAKE :- Sintex Cat part No GSJB-3020 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix GI Octagonal poles 9 Mtr long having top dia 70mm, bottom dia 155mm, Sheet thickness 3mm, base plate dimension 250 x 250 x 16mm (LXBXT) including nuts, bolts & screws suitable PCC foundation if required as per manufacture instructions complete all as specified and as direceted. NOTE :- (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 mtr top of coping shall be painted with 2 coats of black and white strips alternate layers of 30cm each over one coat of red oxide primer. (iii) Steel tubular pole above 1.5 mtr shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv) Pole below ground shall be tarred by one coat (v) Poles shall be numbered and the rate for above items shall be deemed to be included in the quoted rate.
Supply and fix 100 watt LED street light luminaries comprising of cast aluminium housing, toughned glass, IP-66 protection and impact resistance of IK07 with 10KV build in surge protection device wired with all accessories enclosed with glass cover in frame, fixed with and including suitable size of GI brackets, clamps having two coats of synthetic enamal paint, nut, bolts all as specified and as directed. MAKE :- Wipro Cat Part LR06-112-XXX-57-XX or equivalent in Crompton Cat Part LSTP-100-CDL-M or Havells Cat Part ENDURA OMNIPLUS SL100WLED 757SASY TOPC
Supply and fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS GI clamps with necessary bolts, nuts and washers all as specified of size 40mm bore all as specified and as directed.
Material and labour plain cement concrete (1:3:6), type C1, using 40 mm graded stone aggregate as in cement concrete foundations, filling and mass concrete complete all as specifed and as directed.
Material and labour plain cement concrete,(1:2:4), type B1, using 20 mm graded stone aggregate as in coping of pole sand including form work complete all as specifed and as directed.
Material and labour for making hole on a street light pole top and bottom for entry and including of service wire of 2.5 sq.mm 3 core connection from junction box to fitting complete all as specified and as directed.
Supply and fix steel tubular swaged poles 11 Mtr long complete with MS base plate of 6mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screws, pole made out of ERW MS tubing confirming to IS-2713 part II, 410 SP-55(11.00 meters long) poles including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of black bituminous paint for portion embedded in concrete complete with cast iron base plate finial taper plug bolts, nuts and screws complete all as specified and as directed.
Supply and fix rolled mild steel as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and finishing coat of paint of aluminium paint complete all as specified and as directed.
Supply and fix flood light fitting with LED 250 watts, white in colour, LM6 aluminium or higher grade powder coated, water proof pressure die cast aluminium enclosure, with in built electronic drivers, IP 66 protection, single phase, fixing in MS chanel by drilling hole of suitable size, using nut, bolts and washers as required at the site complete all as specified and as directed.
Material and labour for repairs, servicing, cleaning and testing of mechanical chimney, electrically operated 3 phase 4 wire system of the kitchen by replacing of its all unserviceable parts such as electric motor rewinding, starter, dampers of exhaust, exhaust opening pipe, bearings, shafts etc of suitable size including its connected items required at site and make it serviceable complete all as specified and as directed.
Supply and fix of exterior RGBW LED flood lighting luminaire, round type, COMPASS 28W ± 15 % DMX 25° with dedicated optics for architectural lighting, the luminaire should have high strength aluminium die cast fixture with anti-aging, anti-corrosion electrostatic coating with aesthetically designed heat shink for efficient thermal management, powder coated toughned glass, PC lens with symmetric and elliptical distribution, toughened glass cover with high impact resistance strength, the operating voltage range is 100-277 volts, AC, PF - > 0.9, 50Hz ± 3%, built-in potted electronic LED driver with APFC, lower THD, open circuit protection, over voltage protection, surge voltage protection upto 4kV, the luminaire should be IP 66 and IK 07 type, the luminaire should be 50000 hr @ amb temp, the product should be BIS approved with R number mentioned on product label, to be supported with product test reports - LM79, BIS Report and LEDs test reports, luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. - RGB /RGBW - with CRI>70 - LED Luminaire, Luminaire of 28W ± 15 %, System lumen output of Per No 1640 lumens ± 3%, The luminaire beam angles of 25° complete all as specified and as directed.
Supply and fix of M15 female cable 1 Meter with IP-67 connector complete all as specified and as directed.
Supply and fix of M15 extension cable 1 Meter, 3 pin, IP-67 connector complete all as specified and as directed.
Supply and fix of M15 extension cable 3 meter, 3 pin with IP-67 connector complete all as specified and as directed.
Supply and fix of IP-66 protected junction box with connectors complete all as specified and as directed.
Supply and fix of exterior RGBW LED linear wall washer of 60 W ± 15 % with dedicated optics for architectural lighting, the luminaire should have high strength aluminium die casted fixture with anti-aging, anti-corrosion electrostatic coating with aesthetically designed heat shink for efficient thermal management, powder coated toughned glass, PC lens with symmetric and elliptical distribution, toughened glass cover with high impact resistance strength, with internal/ external LED driver, the operating voltage range is 100-277V AC, PF - > 0.9, 50Hz ± 3% , built-in potted electronic LED driver with APFC, lower THD, open circuit protection, over voltage protection, surge voltage protection, upto 4kV, the luminaire should be IP 66 and IK 07 type, the luminaire should be 50000 hr @ amb temp, the product should be BIS approved with R number mentioned on product label, to be supported with product test reports - LM79, BIS report and LEDs test reports, luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. - RGBW - LED luminaire, luminaire of 60W ± 15 % - 1 mtr length, system lumen output of Per No 2800 lumens ± 3%, the luminaire beam angles 25° complete all as specified and as directed. MKAE :- Havells Cat No. Lineate INT 60W DMX 25° or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix of exterior BIS registered RGBW flexible LED strip having 60 Nos LEDs per meter through out the length with the silicon cover, standard length of LED strip is 5 mtr and it shall be capable of producing dynamic colour changing light with 16 million colours and should be programmable using 8 bit control DMX512 protocol / ethernet based control, the strip should have IP-67 protection with inbuilt IP-67 connectors at both ends, DMX enabler circuit should be outside the luminaire/LED strip only, LED strip shall be suitable to operate at an ambient temperature range of 20°C to 50°C, life time shall be at least L70B50 @ 35000 burning hours at 50°C, LED should be of make Nichea, Osram, Cree, Lumiled, Hongya of 5050 SMD package only, the rated voltage of the Luminaire should be 24VDC, luminaire shall be offered with a BIS approved potted driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, LED driver should have operating input voltage range: 90-305 Vac, PF > 0.95 and must have safety operation range form 90V - 176 Vac, life time of LED driver should be > 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, LED driver must have SELV output and case temperature i.e. Tc > 90°C, the product should be BIS approved with R number mentioned on product label, to be supported with product test reports - LM79, BIS Report and LEDs test reports, luminaire shall be conforming to BIS i.e. IS 10322 (PART 5/SEC 7) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required, LED strip of 14.4W/M ± 15 % - system lumen output of per No 3500 lumens ± 3% for 5 Mtr role complete all as specified and as directed.
Supply and fix of LED driver IP-66, 250 Watt with 24 volts complete all as specified and directed. MAKE :- Havells Cat No. LEDDRIVERCV250W 24V 10.5A EBV250S024SV or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix of DMX decoder for RGBW flexi strip 12V/24V- 480 Watt complete all as specified and as directed. MAKE :- Havells Cat No. DMX DECODER_RGBW_12V/24V_480W or techno commercially equivalent model in makes as per Appendix 'C'.
Supplyand fix of signle amplifier for RGBW strip, instruction forwarder Ranger / Compass(AC) / strip complete all as specified and as directed.
Supply and fix of 1 Mtr wire 5 pin IP-67 female cable with connector for RGBW flexi strip complete all as specified and as directed.
Supply and fix of 1 Mtr wire 5 pin IP-67 extension cable with connector for RGBW flexi strip complete all as specified and as directed.
Supply and fix of aluniminum profile with diffuser complete all as specified and as directed.
Supply and fix of exterior BIS registered mono colour - 3K flexible LED strip of wattage 14.4 W/Mtr ± 15 % lumen output 1260, with CRI >80, LED strip should have 60Nos LEDs per meter through out the length with the silicon cover, standard length of LED strip is 5 mtr, the strip should have IP-67 protection with inbuilt IP-67 connectors at both ends, LED strip shall be suitable to operate at an ambient temperature range of 20°C to 50°C, life time shall be at least L70B50 @ 35000 burning hours at 50°C, LED should be of make Nichea, Osram, Cree, Lumiled, Hongya of 5050 SMD package only, the rated voltage of the luminaire should be 24VDC, luminaire shall be offered with a BIS approved potted driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, LED driver should have operating input voltage range: 90-305Vac, PF > 0.95 and must have safety operation range form 90V - 176Vac, life time of LED driver should be > 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, LED driver must have SELV output and case temperature i.e. Tc > 90°C, the product should be BIS approved with R number mentioned on product label, to be supported with product test reports - LM79, BIS Report and LEDs test reports, luminaire shall be conforming to BIS i.e. IS 10322 (PART 5/SEC 7) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required complete all as specified and as directed.
Supply and fix of 1 Mtr wire, 2 pin, IP-67 female cable with connector mono complete all as specified and as directed.
Supply and fix of LED driver 150 Watt with IP-66, 24 volts complete all as specified and as directed. MAKE :- Havells Cat No.LEDDRIVERCV150W24V6.3AEBV150 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix of exterior LED linear wall washer RGBW with dedicated optics for architectural lighting, the luminaire should have high strength aluminium die casted fixture with anti-aging, anti-corrosion electrostatic coating with aesthetically designed heat shink for efficient thermal management, powder coated toughned glass, PC lens with symmetric and elliptical distribution, toughened glass cover with high impact resistance strength, with internal/ external LED driver, the operating voltage range is 100-277V AC, PF - > 0.9, 50Hz ± 3% , built-in potted electronic LED driver with APFC, lower THD, open circuit protection, over voltage protection, surge voltage protection upto 4kV, the luminaire should be IP 66 and IK 07 type, the luminaire should be 50000 hr @ amb temp, the product should be BIS approved with R number mentioned on product label, to be supported with product test reports - LM79, BIS report and LEDs test reports, luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc., warm white - CCT of 3000K with CRI>70 - LED luminaire, luminaire of 24W ± 15 % - 1 Mtr length, system lumen output of per No 2000 lumens ± 3%, the luminaire beam angle 25° complete all as specified and directed. MAKE :- Havells Cat No. Linete 24W 25° DMX wall washer or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix of M16C, 2 pin, 1 Meter female cable with IP-67 connector complete all as specified and as directed.
Supply and fix of M16C, 2 pin, 1 meter extension cable with IP-67 connector complete all as specified and directed.
Supply and fix of M16C, 2 pin, 3 meter extension cable with IP-67 connector complete all as specified and as directed.
Supply and fix of LED driver 150 Watt with IP-55 24 volts complete all as specified and directed. MAKE :- Havells Cat No. LEDDRIVERCV150W24V6.3AEBV150 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix of DMX controller for the system including all other accessories required for the running of the system, controller should have input power 5-5.5V, DC 0.6A and output protocol DMX 512(x4), it should be compatible for programmability with PC, Mac, tablet, smartphone. it must have connections Mini USB, XLR3, XLR5, Ethernet, 2xHE10, battery, there should be provision for memory micro SD card, it is an IP20 unit and has an operating temperature of 0°C to 50°C, dimensions should be79x92x43mm and weight should not be more than 120g, OS requirements for the controller is Mac OS X10.8-10.12, Windows7/8/10, standards should be EC, EMC, ROHS. the controller should have a variety of features including 1024 DMX channels, clock/calendar, iPhone / iPad / Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory, network synchronization of one area across hundreds of universe switch, the possibility of 250 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions,the controller should be supplied along the atleast 6 port network hub along with the controller which can be connected on cloud server and integrated with the android device for controlling various scenes, the facade lighting products and DMX controller should be of same / single make complete all as specified and as directed. MAKE :- Havells DMX CONTOLLER UE11 or techno commercially equivalent model in makes as per Appendix 'C'.
Supply and fix of address writer suitable for DMX 512 controller complete all as specified and as directed.
Supply and fix of instruction forwarder ranger / compass (AC) suitable for DMX 512 controller complete all as specified and as directed.
Supply and fixing of DMX Splitter cum Booster ,Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz.,Housing rugged alluminium, Operation Temperature -17ºC ~ +55ºC (0ºF ~ 131ºF) , 5/6 output ports with 3/5-pin terminal sockets , each port should be optically isolated , Protection Rating IP20 including connection complete all as specified and directed Make : Philips/Wipro/Havells/Halonix
Provision for programming of software with 08 Nos of themes by qulaified rep of OEM complete testing, trail run of themes as per site requirement upto satisfaction and approval by GE complete all as specified and as directed by Engr-in-Charge as per site requirement.
Supply and fixing of Cat 06, four paired twisted wire UTP 23 AWG, pure copper unsheilded PVC bulk cable as per ISI/ BIS standard including PVC conduit pipes of dia not less than 19 mm complete all as specified and directed.
Material and labour for PVC insulated 2.5 sq.mm 4 core copper conductor 1100 volts FRLS grade ISI marked including PVC conduit pipes of dia not less than 19 mm complete all as specified and as directed.
Taking up or down 80/40 mm bore GI water tubing and connections of pipe and fittings including segregating of serviceable pipes and keeping in safe custody for reuse in the work and removing unserviceable pipes and fittings from site of work complete all as directed.
Taking up or down 25 mm bore GI water tubing and connections of pipe and fittings including segregating of serviceable pipes and keeping in safe custody for reuse in the work and removing unserviceable pipes and fittings from site of work complete all as directed.
Supply and fix galvanised iron tubing 'medium grade' 80 mm bore, with all fittings (Tee, elbow, nipple, reducer, union) clamps, screws, MS clamps, hooks complete as in laying in ground / fixed on wall / floors /ceilings all as specified and as directed.
Supply and fix galvanised iron tubing 'medium grade' 40 mm bore, with all fittings (Tee, elbow, nipple, reducer, union) clamps, screws, MS clamps, hooks complete as in laying in ground / fixed on wall / floors /ceilings all as specified and as directed.
Supply and fix galvanised iron tubing 'medium grade' 25 mm bore, with all fittings (Tee, elbow, nipple, reducer, union) clamps, screws, MS clamps, hooks complete as in laying in ground / fixed on wall / floors /ceilings all as specified and as directed.
Supply and fix in replacement of bronze gate valves (hexagonal type) 80mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
Supply and fix in replacement of bronze gate valves (hexagonal type) 40mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
Supply and fix in replacement of bronze gate valves (hexagonal type) 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
Supply and fix ball (float) valves, high pressure of brass with epoxy coated brass rod and high density plastic ball, screwed for 25mm bore iron pipe, including replacement of adjacent GI fittings (socket, nipple,reducer socket,etc.) where necessary complete all as specified and as directed.
Material and labour for valve pit chamber on exisiting chamber foundation with 230 mm thick brick wall in CM (1:6), 75 mm thick coping with PCC (1:2:4) type B1, 15 mm thick plaster work in CM (1:4) to all internal and external wall surfaces with three coats white wash on both surfaces and MS sheet cover of suitable thickness for valve pit chamber of size 900x900x750 mm with hinges, equal angle iron frame and necessary locking arrangements painting with two coats of synthetic enamel paint over coat of red oxide primer on MS plate including dismantling existing chamber and removal of all debris all as specified and directed,
Material and labour for boring of holes under road, pavements, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of upto 150mm dia suitable for 0.4 Mpa working pressure complete all as directed for passing GI pipe of bore size 15/20/50mm dia complete all as specified and as directed. NOTE :- Damages to any existing cable/ pipeline if any, will be repaired immediately and cost for the repairs are deemed to be included in the quoted rate.
Supply and installation of extendable type 100 % all inverter variable refrigerant flow outdoor units comprising of hermetically sealed inverter variable speed scroll compressors, the unit shall comprise of high efficiency, low noise condenser, fan with guard and IP-55 motor, heat exchanger and coated fins for increased durability, the casing shall be powder coated and the unit shall be provided with liquid line strainer, catch all drier, thermostats etc., suitable for interconnecting with any type of indoor units with cordless / corded remote controller, the ODU & IDU shall be integrated with special super wiring system, the unit shall be factory wired and tested before dispatch, the operating refrigerant shall be R-410A /R 32 only, outdoor should give 100% capacity at 43 Deg C ambient temperature, the Condensing unit shall have compressors of 16HP and above capacity with following specifications :- (a) Supply of VRF based vertical tower AC complete with fan section with fan/cooling coil suitable for HFC-410A/R32 with electronic expansion valve, return air filter, insulated drain tray, inbuilt drain pump and necessary controls, 4 TR-3 Nos. (b)Supply of Remote controllers & refnet joints as designed by OEM, cordless remote-03 Nos, refnet Joints (indoor unit) -02 Nos, refnet Joints (outdoor unit)
Supply, installation of extendable type 100 % all Inverter variable refrigerant flow outdoor units comprising of hermetically sealed inverter variable speed scroll compressors, the unit shall comprise of high efficiency, low noise condenser fan with guard and IP-55 motor, heat exchanger and coated fins for increased durability, the casing shall be powder coated and the unit shall be provided with liquid line strainer, catch all drier, thermostats etc., suitable for interconnecting with any type of indoor units with cordless / corded remote controller, the ODU & IDU shall be integrated with special super wiring system, the unit shall be factory wired and tested before dispatch, the operating refrigerant shall be R-410A /R 32 only, outdoor should give 100% capacity at 43 Deg C ambient temperature, the condensing unit shall have compressors for 32HP(2x 16HP) and above capacity. a) Supply of VRF based vertical tower AC complete with fan section with fan / cooling coil suitable for HFC-410A/R32 with electronic expansion valve, return air filter, insulated drain tray, inbuilt drain pump and necessary controls, 4 TR-5 Nos. (b) Supply of remote controllers & refnet Joints as designed by OEM, cordless Remote-05 Nos, Refnet joints (indoor unit) -04 Nos, Refnet joints (outdoor unit).
agarwal and company
SIGNATURE INFRASTRUCTURES(E DHARANI KUMAR REDDY)
Shree Ayyappa Engineering
Garima Construction Co
Horizon Construction
Nexus Infratech
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .