Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
17 Sept 2024, 3:00 pmClosed
Chief Manager (Infrastructure)
Chief Manager (Infrastructure), IIMB
Renovation of Classrooms at K Cluster at IIMB-Electrical Works
2024_IIMB_824402_1
CMI/SMCD/37/2027-25
Limited
Electrical Works
Item Rate
45 days
IIMB
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
19 Sept 2024
4 Sept 2024
18 Sept 2024
4 Sept 2024
17 Sept 2024
4 Sept 2024
Amount
Supply of 600 x 600 mm ,recess mounted , 36 W, K capacity LED luminarie, 6500 K , colour temperature ,m in Powder coated, CRCA enclosure , with full window acrylic difuser with high efficiency flat low glare diffuser . Power factor >0.95 THD < 12 % ,> Colour temperature - 6000 K . Make : Crompton . Output shall be greater than 100 lm/ Watt
Installation of lighting fixtrues mentioned in Sl no-1 with necessary accessories and hardwares.
Supply and running 2 R x2.5 sq.mm + 1 R 1.5 sq.mm finolex /polycab make PVC insulated, Fire retardent copper multistrand wire in 3/4"or 1" conduit or casing and capping . Conduit shall be fixed to wall / flooring using wood plugs, heavy guage saddles and screws. Rate shall be exclusive of conduit -
Supply and fixing of 25 mm dia 2. .mm thick heavy guage PVC conduit pipe with suitble size bends , PVC junctions adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone sructure or rawl plugs in case of brick walls and cemanet plastering damaged protion using hevay guage saddles at an inveternal of 700 mm using WF screws. -
Supply and running 2 R x4sq.mm + 1 R 1.5 sq.mm Poly cab / finolex make PVC insulated, fire reatrdent copper multistrand wire in 3/4" , 2 mm thick conduit casing and capping wherever necessary.
Supply and laying of 3C x 2.5 sq.mm , multistrnad ,PVC insulated , copper flexible cable.
Supply, Erection, Testing and Commisionning of POP-UP BOX 8 Modules with soft close & with shield - Make -Ebco
Suppl , Erection ,testing and commissioniong of Floor box - Make - MK , suitble for fixing 2 Nos 5A socket and two nos of 5 A switches.
Supply and fixing surface / flushmounting unbreakable PVC modular box suitble for mounting switch plates with due due groove cutting in Brick / CC wall , including necessary rawl plugs, machine screws / NF screws etc. complete.
3 Mdoule
4 Module
8 Module
10 Module
Supply and fixing superior quality modular siwtch mouting polycabonate plate with necessary supporting back plate with requried number of machine screws., bolts nuts etc. complete on the existing metal / PVC box.
3 Mdoule
4 Module
8 M odule
10 Module
12 Module
Supply and fixing modular switch / socket / stepped electronic fan regulator etc on existing modular switch plate as per IS 3854 and IS 1293 . Make : Anchor Roma / Legrand - Mylink
6 A one way switch
6 A/ 16 A , 5 pin 3way , universal socket -
Stepped fan regulartor
Supply and fixing of race ways made of aluminium sections removable covers of 40 mm depth x 100 MM width .
Supply and fixing of PVC race way - 100 mm x 40mm heavy duty . Make : GM , Legrand , MK
Supply and fixing of floor junction box r 300 mm x 300 mm, depth - 50 mm to be connected to race made up GI sheet of 2mm thick with cover hinged cover
Civil works for fixing above floor trunking - Chipping in concrete floor, concreting after fixing the floor trunk and removal of debries .
Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1.1 kV grade , copper , FRLS multistrand flexible conductor, 3 R x1.5 sq.mm with 6 A switch shall be fixed on the existing PVC/ GI box . Theother end of the wires shallbe terminated with sufficient loose length in a wood/ PVC round block. complte for each out lent. Cost of the switch not included. Distance from from switch up to last light fixture considered for measuremnt of point length when more than one light is connected to one point.
Point up to 3 Mtr from tapping point to outlet via switch.
Point above 3 Mtr up to 6 Mtr
Point above 6 Mtr up to 10 Mtr
Core cutting 3" / 4" dia hole in Stone / RCC wall using core drilling machine . Width of wall 600 mm to 750 mm
Supply and fixing of 1.5 " Casing caping of approved make- Modi /Anchor / VIP
Supply and fixing of 2 " Casing caping of approved make - Make - Modi /Anchor / VIP
Supply and laying of 4 C x 4 sq.mn, copper , multristrand , FRLS , Flexible cable. Make : Polycab / Anchor / Finolex.
Supply of 2 TR , Non inverter Cassette AC Unit , Model no , Make - Daiken Model : Indoor : FCQF24ARV16, Out Door unit : RFVF24ASV16 and Panel : BYCQ48EAF-3*
Supply of 2 TR , Non inverter Cassette AC Unit , Model no , Make - Daiken Model : Indoor : FCQF24ARV16, and Panel : BYCQ48EAF-3*
Supply of Out unit stand made of MS angle with anti rust Powder coating. Unit shall be mounted on rubber pads
Supply of refrigerant supply and return lines suitble for above unit( 1/2" and 1/4 ") using Softdrawn pipe with complete foam insulation , Copper tube make - Totalline / Hills . Refrigerant line should be supported by threded rod and slotted angle/ clamps as per the site condition. Refrigerant pipe line shall be insulated with foam insulation
Installation charges for 2 TR Unit as mentioned in SL no -1 with complete indoor and out door units, refrigerant pipes, foam insulation for pipes, Installation of out door unit stand etc.
Installation charges for 2 TR Unit as mentioned in SL no -2 with complete indoor and out door units, refrigerant pipes, foam insulation for pipes, Installation of out door unit stand etc.
Acchu Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .