Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.3 L+₹3.8 L (14.4%)Rejected-Finance 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹30.7 L+₹4.2 L (15.9%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹36.9 L+₹10.4 L (39.4%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹37.8 L+₹11.4 L (42.9%)Rejected-Finance MANNI MOUNTA COMPLEX NEAR SGPGI RAEBARELI ROAD LUCKNOW 226014 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226014 | L5 | Rejected-Finance Being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF WINDOW TYPE ACS, SPLIT TYPE ACS, TOWER ACS, CASSETTE ACS AND VOLTAGE STABILIZERS IN THE AREA OF AGE E/M EXT (WS AND AC) UNDER GE E/M LUCKNOW
2024_MES_648343_1
GE/EM/LKO/EXT(WS)/T-07 OF 2024-2025
Open Tender
Miscellaneous Works
Item Rate
270 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹96,000
Yes
7 Jun 2024
29 Mar 2024
26 Apr 2024
29 Mar 2024
24 Apr 2024
12 Apr 2024
Amount
Deployment of refrigerint mechanic for attending the Complaints of Split AC / Window AC / Tower AC by for rectification for minor deffects and making it in working condition at any location of Cantt area complete all as directed by EIC
M&L for dismantling of burnt contactor and Supply & fix power contactor 1 ph suitbale for Tower AC / split AC / Window AC of any make, model and capacity complete all as specified and directed by Engineer-in- Charge.
M&L for dismantling of defective outdoor stand of split AC and supply & fix new outdoor stand of split AC at suitable location complete all as specified and directed by EIC.
M&L for dismantling of burnt capacitor and Supply & Fix new capacitor of capacity 36 Mfd in plastic / metal container complete all as directed by EIC.
M&L for dismantling of burnt capacitor and Supply & Fix new capacitor of capacity 50+5Mfd in plastic/ metal container complete all as directed by EIC.
M&L for dismantling of burnt capacitor and Supply & Fix new capacitor of capacity 45 Mfd in plastic/ metal container complete all as directed by EIC.
M&L for dismantling of burnt Indoor unit Censor and Supply & Fix new Censor (in each set) of Indoor unit Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC.
M&L for dismantling of burnt Outdoor unit Censor and Supply & Fix new Censor (in each set) of Outdoor unit Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC
M&L for dismantling of burnt Swing motor and Supply & Fix new Swing motor for 1.5 TR / 2 TR indoor unit of split AC all as directed by EIC.
M&L for dismantling of burnt Swing motor and Supply & Fix new Swing motor for 1.5 TR / 2 TR indoor unit of split AC Inverter type (cooling only / hot & cold type) all as directed by EIC.
M&L for dismantling of burnt Swing motor and Supply & Fix new Swing motor for 1.5 TR / 2 TR window AC all as directed by EIC.
M&L for dismantling of defected brass suction valve and Supply & fix new brass suction valve size 3/8" complete all as specified and directed
M&L for dismantling of defected Discharge valve and Supply & fix new Discharge valve size 1/2" complete all as specified and directed .
M&L for dismantling of defected charging valve and Supply & fix new charging valve size 1/4" complete all as per directed by EIC
M&L for dismantling of defected flare nuts and Supply & fix new flare nuts size 3/8" complete all as specified and directed.
M&L for dismantling of defected flare nuts and Supply & fix new flare nuts size 1/4"complete all as specified and directed.
M&L for dismantling of defected flare nuts and Supply & fix new flare nuts size 1/2" complete all as specified and directed
M&L for dismantling of defected flare nuts and Supply & fix new flare nuts size 5/8" complete all as specified and directed
M&L for dismantling of defected copper gas filter and Supply & fix new copper Gas filter for AC 1.5 TR / 2 TR capacity all as specified and directed
M&L for dismantling of burnt electric connector and Supply & fix new electric connector suitbale for Tower AC / split AC / Window AC of any make , model and capacity complete all as specified and directed by Engineer-in- Charge.
Supply & fix / connecting and testing of 3 core, 2.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694, for power supply of any type AC including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F in repair MCB SP -6 to 32 Amps rating to be housed in DBs catered here in after complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating):-
S&F in repair Mettalic Plugs ( top) of AC box 20 A, 2P+E and connecting all as specified and directed
S&F in repair copper capillary of size 0.60 mm complete all as specified and directed
S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified
M&L for repairing of leackage from copper tube by soldring / brazing etc of Tower AC, Split AC, Window AC of 1.5 TR / 2.0TR capacity of any make and model at any location of cantt area, after rectification of lecakage testing of leakage, vaccumnisation and charging of refrigerant (R-22 / R-32 / R-410) and making unit fully functional complete all as directed by EIC. Note :- Refrigerant gas will be provided by Contractor.
Supply & fix in repair puff insulation of size1/2" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
Supply & fix in repair puff insulation of size1/4" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
Supply & fix in repair puff insulation of size5/8" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
Supply and fix in repair PVC pipe nylon braided 15 mm dia for condensed water drain fitted with clamps / concealed in wall all as specified and directed.
Supply and fix in repair of copper tubing 3/8"dia with puff insulation complete all as specified and directed .
Supply and fix in repair of copper tubing 1/2" dia with puff insulation complete all as specified and directed .
Supply and fix in repair of copper tubing 1/4" dia with puff insulation complete all as specified and directed .
Supply of wireless remote control hand set of window type air conditioner of cap 1.5 / 2.0 TR of existing make with and including pencil cells complete all as specified and directed.
Supply of wireless remote control hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
Supply of wireless remote control hand set of Inverter type Split air conditioner (hot & cold type) of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
Supply and fix in repair Air Censor for temperature control for 1.5 TR / 2.0 TR Split AC / Tower AC / Window AC complete all as specified and directed.
Supply and fix in repair PVC fan blade with gun metal bush of blower, Screw complete all as directed by EIC
Supply and fix in repair PVC blower for window A.C. as per sample complete all as specified and directed
M&L for taking down of Split type AC (Indoor & outdoor complete) of any capacity or model and transporting and refixing at New Location to make it fully functional again at new location with all as specified and directed by Engr-In -Charge.
M&L for taking down of Window AC any capacity or model, transporting and refixing at New Location to make it fully functional again all as specified and directed by Engr-In -Charge.
Taking out defective blower motor from window type AC of cap 1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1/ 5 to 1/ 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR / 2.0 TR split AC (indoor unit) and supply & fixing new blower motor Suitable for Carrier / Voltas / Blue star / LG / Samsung Make ACs as per sample complete all as specified and directed.
Dismantling of burnt outdoor fan motor of 1.5 TR / 2.0TR split AC (outdoor unit) and supply & fixing new outdoor fan motor Suitable for Carrier / Voltas / Blue star / LG / Samsung Make ACs as per sample complete all as specified and directed.
Dismantling of defective indoor unit of 2.0 TR capacity Tower AC and supply & fixing new indoor unit Tower AC of the same capacity with blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit all as specified and directed. ( Make :- Bluestar/ Voltas//LG/ Hitachi)
Dismantling of existing window type AC. from its location and refixing after doing by Servicing by oiling & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filter complete with cleaning of Cooling & Condensing coil all as directed by EIC.
M&L for painting of outer cage and front grill of window type AC or indoor unit & outdoor unit of Split type AC or Tower AC of any make & capacity with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paper including writing SM No. / MES No. etc complete all as directed by EIC
Taking down outdoor unit of Tower Ac / split AC any make / model / capacity and transporting from site to contractor workshop for carrying out repairs and renewal / replacements of Parts including servicing and liquid soap washing, after repairing the same, transporting back to site, make it fully functional reassemble and installation on existing same location with complete all as specified and directed. (Note :- M&L for parts renew/ replacements shall be measured and paid separately under appropriate item(s)
M&L for rectification of Water dropping from Tower AC, Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC
Deployment of refrigering technician for convert to heating mode in cooling mode (only reverse cycle connection) in Split AC, Window AC of any make, model and capacity at any location of cantt area with complete all as directed by EIC
M&L for Renewal of plywood 6 mm thick, BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished to cover space of window or wall for fix of window AC any capacity to complete as directed by EIC
M&L for Renewal of 2nd class HW (SAL) fillets, cross sectional area 50 mm x 50 mm approx on all four sides of window type AC splayed or chamfered edge including applying two or more coat french polish etc complete all as specified and directed.
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing new indoor unit Inverter type (hot & cold) type of the same capacity with blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall / ceiling mounted all as specified and directed.
Dismantling of defective cooling coil of 1.5 TR / 2.0 TR window type AC of any make and S&F new cooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
Dismantling of defective condencing coil of 1.5 TR / 2.0 TR window type AC of any make and S&F new condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
Dismantling of defective cooling coil of 1.5 TR / 2.0TR Split AC of any make and S&F new cooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
Dismantling of defective condencing coil of 1.5 TR / 2.0TR Split AC of any make and S&F new condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
Dismantling of burnt fan motor of 1.5 TR / 2.0TR window AC double shaft and supply & fixing new fan motor Suitable for ACs as per sample complete all as specified and directed.
Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.
Dismantling of unserviceable compressors of 2 TR capacities including disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.
Dismantling of unserviceable compressors of 1.5 TR capacities of window / split type ACs including disconnecting suction / discharge copper tubing and S&F new compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately. (iii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier / Kirloskar / Blue star.
Dismantling of unserviceable compressors of 2 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F new compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately. (iii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Supply and fix in repairs front grill for window AC of 1.5 TR / 2 TR all as specified and directed
M&L for fabrication of Tray for Window AC made out of 24 SWG thick mild steel sheet with 10 mm aperture including rivetting brazing / soldering including painting with two coat of (black) enameled paint over one coat of red oxide primer and installed at locations complete all as specified and directed.
Dismantling of defective condensing unit ( outdoor unit) of Tower AC of 2.0 TR capacity and supply & fixing new condensing unit (outdoor unit) of Tower AC 2.0 TR capacity complete with compressor, Copper condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed.
M&L for servicing of Split AC, and tower AC s 1.5 / 2.0 / 3.0 / 4.0 TR Indoor & out door unit by means of electric blower & water under pressure, cleaning & washing of cooling & condencing coil by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc complete all as specified and directed by EIC.
M&L for Nitrogen pressure testing, flushing out the system by Nitrogen, vacumrnation and charging of refrigerant gas R-22 / R-32 / R-410 into the system for 1.5 TR / 2.0 TR capacity split type AC all as specified and directed. (The refrigerant gas will be provided by Contractor)
M&L for Nitrogen pressure testing, flushing out the system by Nitrogen, vacumrnation and charging of refrigerant gas R-22 / R-32 / R-410 into the system for 1.5 / 2.0 TR capacity window type AC all as specified and directed. (The refrigerant gas will be provided by Contractor)
Supply & Charging in full the AC unit of 1.5 TR / 2 TR split AC/ window AC unit with refrigerant gas R-22 / R-32 / R-410 in required Qty complete all as specified and directed (The refrigerant gas will be provided by Contractor)
Supply & fix in repair display unit suitable for Split AC / window AC / Tower AC of any make/ model & capacity complete all as directed by EIC
Supply & fix in repair display unit suitable for Inverter Split AC (cooling or Hot & cold type) of any make / model & capacity complete all as directed by EIC.
M&L for dismantling of defective display unit of 1.5 / 2.0 TR capacity Split AC / Window AC of any make and transporting to contractors workshop for repair of the same, transporting back to site & refixing to ensure proper functioning of the AC complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR / 2.0 TR split AC (indoor unit) Inverter Split AC and supply & fixing new blower motor of Inverter Split AC (Cooling or hot & cold type) complete all as specified and directed.
Dismantling of burnt outdoor fan motor of 1.5 TR / 2.0 TR split AC (outdoor unit) Inverter Split AC and supply & fixing new outdoor fan motor of Inverter Split AC (Cooling or hot & cold type) as per sample complete all as specified and directed.
S&F in repair reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction / discharge copper tubing & toggle switch complete all as specified and directed by Engineer-in- Charge.
Dismantling of defective condensing unit (outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit (outdoor unit) Inverter type (hot & cold) of the same capacity complete with compressor, copper condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed.
S&F in replacement New PCB for indoor unit of (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5 / 2.0 TR Split AC complete all as specified and directed.
M&L for dismantling of defective PCB of 1.5 / 2.0 TR capacity Split AC of any make from indoor unit and transporting to contractors workshop for repair of the same, transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
M&L for dismantling of defective PCB of 1.5 / 2.0 TR capacity window type AC of any make from indoor unit and transporting to contractors workshop for repair of the same, transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
S&F in replacement New PCB for window AC of Cap 1.5/2.0 TR of any make/ model complete all as specified and directed.
S&F in replacement New PCB for indoor unit of (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed.
S&F in replacement New PCB for Outdoor unit (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed.
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type (cooling only/ hot & cold) of any make from indoor or outdoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
M&L for dismantling of burnt capacitor and Supply & Fix new capacitor of capacity 2.5 Mfd in plastic container complete all as directed by EIC.
M&L for dismantling of burnt capacitor and Supply & Fix new capacitor of capacity 4/ 6 Mfd in plastic container complete all as directed by EIC.
Dismantling of unserviceable compressors of 3 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor scroll type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately. (iii) The compressor of make – Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 4 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor scroll type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately. (iii) The compressor of make – Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors inverter type of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary inverter type type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note : (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately. (iii) The compressor of make – Model No KTN130D42UFZ and Equivalent of other make and model Carrier/ Kirloskar/ Blue star
Supply and fix in repair Polycarbonate Plug top 3 pin 16 Amp complete all as specified and directed.
M&L for taking down unserviceable voltage stablizers of any make of 4 / 5 KVA capacities and dismantling the stablizers of any size for repair of the defective parts / spares & ressembling including repairs of defective screws, rubber shose testing and after repair refixing the same at existing location complete all as specified and directed Note:- Spare parts measured and paid seprately
Supply only relay 25/30 Amps 24 volts for 4 KVA/5KVA voltage stablizers complete all as specified and directed
Supply only main PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed
Supply only Relay PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed
Supply only 2 mtr long copper cable 3 core PVC insulated and sheathed 80/.20(2.5 Sqmm) size duly fitted with 3 pin top 20 Amps all as specified and directed
Supply only power transfromers suitable for voltage stablizers of capacity 4/5 KVA all as specified and directed
Supply only AC volt meter square/round type 0-300 volts suitable for 5/4 KVA single phase voltage stablizers complete all as specified and directed
supply and fix in repair of dimmer type transfromer for 4KVA/5KVA Voltage stablizers all as specified and directed by EIC
Note for All items of this BOQ:- All window / split / tower AC provided at site are of make samsung / carrier / hitachi / bluestar / voltas / LG. contractor special attention is invited that all the spear part of window / split / tower AC shall be of make as recommended by the OEM and approved by the GE.
VISHAL TRADERS
M/s Acme Engineers and Contractors
NAVJYOTI ENTERPRISES
COOLING CENTRE
Uma engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .