Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.9 CrAdmitted-Finance | -9.11% | ₹5.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.1 CrAdmitted-Finance | -5.55% | ₹6.1 Cr | L2 | Admitted-Finance |
Tender Value
₹6.5 Cr
EMD Value
₹13.0 L
Closing Date
28 Apr 2026, 6:00 pmClosed
EE, ADA, Ajmer
ADA, Ajmer
Providing and Fixing HVAC System in Surgical Block JLN Hospital , Ajmer.
2026_ADA_549634_1
59/2025-26 (1)
Open Tender
Electrical Works
Percentage
365 days
ADA
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Yes
ADA, Ajmer
₹13.0 L
Yes
4 May 2026
7 Apr 2026
29 Apr 2026
7 Apr 2026
28 Apr 2026
7 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of Wall mounting cubical type Starter panel made out of 1.6 mm thick sheet steel powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of following cfm range Air Washer's Blower motor, pump comprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | - | - | - |
| 2 | Upto 7500 cfm | - | Set | - | - |
| 3 | more than 7500 cfm to 15000 cfm | - | Set | - | - |
| 4 | Supply , Installation, Testing and Comissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | Set | - | - |
| 5 | P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | Sq.Mtr | - | - |
| 6 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | - | - | - |
| 7 | 0.60 mm | - | Sq.Mtr | - | - |
| 8 | 0.80mm | - | Sq.Mtr | - | - |
| 9 | 1.00mm | - | Sq.Mtr | - | - |
| 10 | 1.25mm | - | Sq.Mtr | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
bid.pdf
Tender Documents • 10.52 MB
BOQ_979849.xls
BOQ • 0.58 MB
59c.pdf
PDF • 0.72 MB
59c.pdf
PDF • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].