| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 CrAccepted-AOC RAMNAGAR COLONY MOHADDIPUR GORAKHPUR U P 273008 | ₹13.3 Cr Quoted ₹11.3 Cr | L1 | Accepted-AOC Qualified |
| 2 | L2₹11.8 CrRejected-Finance | ₹11.8 Cr | L2 | Rejected-Finance High Amount Quoted |
Tender Value
₹11.3 Cr
EMD Value
₹56.6 L
Closing Date
28 Jan 2026, 2:30 pmClosed
Excutive Engineer
GDA Office, Taramandal, Gorakhpur.
Please refer Tender documents.
2026_GORDA_1106915_1
35/GDA/2025-26/06012026
Open Limited
Civil Works
270 days
Near RKBK
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹56.6 L
20 Feb 2026
17 Jan 2026
28 Jan 2026
17 Jan 2026
28 Jan 2026
17 Jan 2026
17 Jan 2026 - 28 Jan 2026
Boring,providing and installation bored cast-in-site reinforced cement concrete piles of grade m-25 of specified diameter and length below the pile cop,to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.by percussion drilling using direct mud circulation (DMC)or bailer and chise technique by tripod and mechanical winch machine all complete,including removal of excavated earth with all its lifte and leads (length of pile for payment shall be measured up to bottom of pile cop).300 mm dia piles (DSR-20.3.1/2023)
Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.5 mtr etc complete DSR NO 2.8.1/2023
Concrete with 4.00cm (1.5") gauge approved stone ballast, approved coarse sand and cement in the proportion of 1:4:8 including supply of materials, labour T&P etc. required for the proper completion of the workDSR 4.1.8/2023
providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources , all works upto plinth level,concrete of M25grade with minimum cement content of 330 kg /cum , (DSR NO 5.33.1.1/2023) Below plinth level
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (D.S.R. No-5.9.1/2023)
Centering and shuttering including strutting, propping etc. and removal of form for wall etc. (D.S.R. No-5.9.2/2023)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more Pile 650x3x3.14x0.15x0.15=105.98 cum (D.S.R. 5.22.6/2023)
Providing and laying Non Pressure NP-3 class (Medium duty)600mm dia R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1.2 (1 cement : 1 fine sand) including testing of joints etc. complete (D.S.R. 19.35.2)
1:2 :4 (1 Cement: 2 coarse sand (zone-III) derived from natural source : 4 graded stone aggregate 20 mm nominal size derived form natural sources) (D.S.R.4.1.3)
Part -B (Near RKBK SPS and Mandir)
Boring,providing and installation bored cast-in-site reinforced cement concrete piles of grade m-25 of specified diameter and length below the pile cop,to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.by percussion drilling using direct mud circulation (DMC)or bailer and chise technique by tripod and mechanical winch machine all complete,including removal of excavated earth with all its lifte and leads (length of pile for payment shall be measured up to bottom of pile cop).450 mm dia piles (DSR-20.3.3/2023)
Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.5 mtr etc complete DSR NO 2.8.1/2023
Concrete with 4.00cm (1.5") gauge approved stone ballast, approved coarse sand and cement in the proportion of 1:4:8 including supply of materials, labour T&P etc. required for the proper completion of the workDSR 4.1.8/2023
providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources , all works upto plinth level,concrete of M25grade with minimum cement content of 330kg /cum , (DSR NO 5.33.1.1/2023) Below plinth level
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (D.S.R. No-5.9.1/2023)
Centering and shuttering including strutting, propping etc. and removal of form for wall etc. (D.S.R. No-5.9.2/2023)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more (D.S.R. 5.22.6/2023)
Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Techincal specifications
Part- C (Manhole rising, leakage repairing & Airwall chamber)
Rising of existing manhole as per site requirement.
leakage repair in 900 mm dia M.S pipe
Dismantling of Old/Damage and Making of Air wall chamber
leakage repair in main sewer line 900 mm dia D.I. pipe
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
document35.pdf
Tender Documents • 4.14 MB
BOQ_2042400.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid