Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹35.8 L+₹3.1 L (9.40%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹37.4 L+₹4.6 L (14.1%)Rejected-Finance RZG 205 RZG STREET NO 9 PALAM COLONY RAJ NAGAR PART 2 BAGDOLA SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹39.9 L+₹7.1 L (21.8%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
13 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
ADDN ALTN TO AUDIOMETRY ROOM AND BERA ROOM AT ENT DEPT OF AFCME AT SUBROTO PARK
2024_MES_638018_1
GE/SP/ TOKEN-64/2023-24
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹87,200
Yes
28 Mar 2024
18 Jan 2024
15 Feb 2024
18 Jan 2024
13 Feb 2024
1 Feb 2024
Amount
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr-in-charge.
All as per item No 1 above. But not exc 1.5 Sqm .
S &F in reapir of Door Frame:- Made up of 19mm thick plywood (double layered) steel to achieve. Covered externally with 3 mm thick non-woven fabric with appropriate door hinges. Door:- Each door leaf will be 2" thick double layered plywood, insulated internally with acoustic material and externally cladded with 3mm thick non-woven fabric with suitable door handle and lock. Note:- Double doors and single door frameworks constitute this requirement complete all as specified and directed by Engr-In-Charge.
S&F in repair of Observation Window Comprising of double layers 8mm thick glass with the inside glass being placed at an angle of 45 ft degrees, secured to a wooden frame work with rubber gaskets and silica gel. V Shape Glass Fixing complete all as specified and directed by Engr-In-Charge.
S&F in repair of Center partition wall:- Double layered gypsum of 12mm with GI frame work and insulated with glass wool complete all as specified and directed by Engr-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), wooden floor including removing the rubbish off the premises complete all as specified and directed.
M&L for FLOOR- 5 mm thick loop pile carpet, the material attenuates the low frequency waves 125 to 4K Hz and less interference from low frequency sound complete all as specified and directed by Engr In Charge.
Dismantling of ceiling /wall panelling including frame work and board complete all as specified and directed by Engr-in-Charge.
M&L for Audiology Room side Paneling: Gl galvanized iron box panel frame work of 24 gauze perforated to an extent of 70% and of 4"" thick box panel of (8'x1') in dimension with 4""(100MM) thick box panel should have infill acoustic material density varies from 32 & 16 kg/cum (glass wool as acoustic material). The Material should have the ability to attain 50% insertion loss and attenuate incident sound energy from frequencies that are concentrated in the 125 to 8000 hertz range to meet the ANSI standards. The external surface having cladded with noise reduction coefficient rated fabric & the encapsulated panels will be secured to floor with mild steel track frame work made up of 16 gauge of U channel approx size (20mmX55mmX40mm) and fasteners complete. The total thickness of acoustic panel will be 100 mm, and 44 STC Value tested as per IS: 9901 (part – III) – 1981, DIN: 52210 Part – IV-1984, ISO: 140 (part – III) –1995, TRN:- 11080668/.07a/T-031" complete all as specified and directed by Engr-in-charge.
All as per item No 9 above, but for ceiling having mild steel angle frame work (16-gauge mild steel powder coated L angle 50X50mm in size) to support the ceiling panel.
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and as directed by Engr-In-Charge.
M&L for Rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth ( without using extra cement) complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete all as specified and directed by Engr-in-charge.
M&L for preparation of old surface and applying one coat of oil bound distemper white or tinted on wall complete all as directed and specified.
S&F Aluminium(extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as directed and specified.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light point controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing including cancealled wiring in PVC conduit not less than 20mm dia with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover complete for one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 17 above but for one fan point controlled by one switch through regulator.
All as per srl item 17 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 17 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 17 above but for call bell controlled by one push button in indi board as specified and directed by engr-in-chrge.
All as per item No 17 above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire complete all as specified and directed by Engr-in-charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular bell push 1 module 5 amps suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Fan regulator rotary step type 20 watt, 240 volt Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 3 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 4 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 6 module Complete all as specified and directed by Engineer-in-Charge.
S & F in replacement electric calling bell Ding Dong type suitable for 230 volts all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed by Eng-in charge
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non- metallic PVC/metallic conduit incl 4.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire complete all as specified and directed by Engr-in-charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair ultra slim FOS LED Commercial Ceiling Panel Light 2x2 36/40-Watt, 4400 LUMENS complete with all accessories connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed by the Engineer-In- Charge.
Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing metal clad socket single pole and neutral sheet enclosure with and 20A earth plug and socket complete with one single pole MCB 20 amp 240 Volts all as specied and specified and as directed by Engineer-in-Charge.
Supply and fixing exhaust fan 200mm sweep 230volt, 1400 RPM including necessary fixing arrangement for proper fxing on wall as per site requiement complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing XLR 8 port Modular patch panel stock No 251-9040 brand Re-An product suitable for fixing the Audio and Video jack inside the audiometry room complete all as specified and directed by Eng-in- change
Supply and fixing fancase 4 pack 3.5mm plug jack TRS 3 pole stereo male plug 1/' 3.5mm solder type DIY audio cable connector for audiometry room complete all as specified and directed by Eng-in-Charge
Supply and fixing ark 4 Pcs 3.5mm audio video socket stero solder panel Jack connector 3 pole black for audiometry room complete all as specified and directed by Engr-in-Charge
Supply & fix in jack panel complete set for audiometry room for proper connection with XLR-8 port modular patch panel and plug jack with male and female audio cales as per site requirement all as sepecified and directed by Engr-in-Charge.
Supply and fixing basics male to female stereo audio cable plated connectors 6 feet (3.5mm) suitable for audiometry room all as specified and directed by Engr-in-Charge
Supply and install hi wall split units indoor/outdoor copper tube evaporator and condencing unit with capacity of 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 Ton fitted on wall and out door to be fixing on roof/wall as per site requirement including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc up to 3 mtr all as specified and directed by Engineer -in -Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA including fixing on wall and necessary electrical connections all as specified and directed by Engr-In-Charge.
M & L for submain wiring with single core PVC insulated but unsheathed FRLS cable of size 2 Run of 4 sq mm cable and one Run of 4 sq mm earth continuity conductor of similar type cable multistranded copper conductor 1100 volts grade IS:694 marked drawn in and inluding 25mm dia of rigid non metallic PVC conduit , medium grade, ISI marked complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and directed by Engineer-in-charge. (Note :- 2 Run of main cable, one run of earth continuity condctor & one run of PVC pipe shall be measured as one Run unit length) Complete all as specified and directed by Engineer-in-Charge.
M&L for cross arms bracings suppots clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condesning unit on the wall / ground complete all as specified and as directed by Engineer-in-charge
Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20-32 amps complete fixing on wall all as specified and directed by Engineer-in-charge
S&F Low density polyethylene pipes (LDPE) 20 mm dia of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc. including accessories, clamps and fastners complete all as specified and as directed by Engineer-in-charge
S&F flexible threaded pvc pipe for drain of water of size 15mm from indoor unit to exist point as per design including accessories clamps fastners complete all as specified and as directed by Engineer-in-charge
M&L laying of copper tubing of dia 1/2" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 1/4" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
Supply, & Fixing of 3 core flexible copper cable of size 4.0 Sq mm 1100 V grade complete fixing on wall by clamping/securing including connections all as specified and as directed by Engineer-in-charge.
J D ENTERPRISES
M/S LADPURIA ENTERPRISES
GIR RAJ BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .