Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.9 LAccepted-AOC OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹1.0 Cr+₹61,790 (0.62%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹1.0 Cr+₹66,800 (0.67%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹1.0 Cr+₹81,830 (0.82%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹1.0 Cr+₹95,190 (0.95%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
20 Nov 2020, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGRS
OUTSOURING SERVICES FOR MAINTENANCE AND UPKEEPING OF E/M INSTALLATION WATER SUPPLY AND ELECTRIC SUPPLY AT JALAPAHAR AND LEBONG AREA UNDER AGE I DARJEELING
2020_MES_388920_1
CWE/136 WE/62 of 2020-21
Open Tender
Civil Works
Item Rate
330 days
DARJEELING
Class C, Category d(v)
8 documents required · 8 mandatory
₹1,000
AGE I DARJEELING
₹1.9 L
Yes
9 Dec 2020
23 Oct 2020
21 Nov 2020
23 Oct 2020
20 Nov 2020
13 Nov 2020
23 Oct 2020 - 30 Oct 2020
60 days
Amount
Manning and operation of Electric supply installation at Jalapahar Power House with a team of one Electrician and one Helper in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of Electric installation such as cleaning of Power house surrounding like cutting of grass, dusting of VCBs, ACBs, Pannel boards etc. for the following type/capacity of equipments complete all as specified and as directed :- (Srl Item No. 1.00 is continued as Srl Item No. 1.01 to 1.10)
HT 11KV VCB Panel (01 No as incoming and 04 Nos as outgoing)
HT 11KV VCB Panel (01 No as incoming and 01 Nos as outgoing)
Indoor Transformer of Cap 500 KVA -01 No & 250KVA - 01No
GOD (11KV Isolator) fitted on Two pole structure--4 Nos
Voltage stabilizer 100 KVA-01 No
LT distribution panel board -3 Nos, DG set AMF Pannel Bd - 01 No
Diesel Engine generating set of capacity 125 KVA - 01 No
Diesel Generating set shall be put on service/operational at the time of failure of civil supply of electricity as and when required.
Filling of log sheets daily and maintaining register for running of DG Set and recording of fuel consumption, collection of fuel when required acounting of consumption daily all as directed by Engr-In-Charge.
Carrying out routine maintainance of DG Set by cleaning of diesel tank, Radiator filling distill water into the battery, filling Engine oil, measuring specific gravity of battery solution, tighting and replacing of nuts/bolts as when required, complete all as directed by Engr-In-Charge.
Manning and operation of Electric supply installation at 163 MH Power House with a team of one Electrician and one Helper in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of Electric installation such as cleaning of Power house surrounding like cutting of grass, dusting of VCBs, ACBs, Pannel boards etc. for the following type/capacity of equipments complete all as specified and as directed :- (Srl Item No. 2.00 is continued as Srl Item No. 2.01 to 2.10)
HT 11KV VCB Panel (01 No as incoming and 02 Nos as outgoing)
Outdoor Transformer of Cap 400 KVA -02 Nos (1 No is floor mounted & 1 No is trolley mounted)
GOD (11KV Isolator) fitted on Two pole structure--2 Nos
LT ACB of Cap 800 Amp 440 volt 3 phase-01 No
LT distribution panel board -1 No, DG set AMF Panel Bd - 01 No and APFC Pannel Bd - 01 No
Diesel Engine generating set of capacity 100 KVA - 01 No
Diesel Engine generating set of capacity 125 KVA - 01 No
Diesel Generating set shall be put on service/operational at the time of failure of civil supply of electricity as and when required.
Filling of log sheets daily and maintaining register for running of DG Set and recording of fuel consumption, collection of fuel when required acounting of consumption daily all as directed by Engr-In-Charge.
Carrying out routine maintainance of DG Set by cleaning of diesel tank, Radiator filling distill water into the battery, filling Engine oil, measuring specific gravity of battery solution, tighting and replacing of nuts/bolts as when required, complete all as directed by Engr-In-Charge.
Manning and operation for day to day maintenance of External Electric supply installations, Overhead conductors, UG cables, Feeder Pillar Boxes, panels and Street lights/security lights at Jalapahar & Katapahar area with two Electrician in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including attending complaints, emergency repair/maintanance work, periodical maintanance of LT panels/Feeder pillar boxes & overhead conductors etc. as detailed by JE E/M complete all as specified and as directed.
Manning and operation for day to day maintenance of External Electric supply installations, Overhead conductors, UG cables, Feeder Pillar Boxes, panels and Street lights/security lights at Lebong area with two Electrician in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including attending complaints, emergency repair/maintanance work, periodical maintanance of LT panels/Feeder pillar boxes & overhead conductors etc. as detailed by JE E/M complete all as specified and as directed.
Manning and operation of water supply installation at Alobari Pump House with a team of one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of pumping installation by tightening the gland of pump, replacing rubber coupling bushes, clearing the leakage of sluice valves, Non return valves by tightening gland and Cleaning of Foot valves etc. Change of Engine oil when required (Engine Oil will be issued by department). Cleaning of pump house surrounding like cutting of grass, dusting of Pump sets, Panel boards, DG set etc, for the following type/capacity of pump sets and other equipments complete all as specified and as directed :- (Srl Item No. 5.00 is continued as Srl Item No. 5.01 to 5.12)
Multi stage centrifugal pump set of 75 HP capacity -02 No and 50 HP capacity 02 Nos
Altoch dozing system full set -01 Set
Semi Underground RCC Reservoir of 30000 Glns capacity -01 No at Pump House
Steel Tank of 14500 Glns capacity -01 No at Pump House
Steel Tank of 5000 Glns capacity -01 No at Pump House
Pressure filter of capacity 35000 Ltrs per Hour - 01 No
All size of control valves at Pump House including distribution valves- 15 - Nos
Diesel Engine generating set of capacity 160 KVA - 01 No
LT distribution/Starter panel board -04 Nos, DG set AMF Pannel Bd - 01 No,APFC Panel --02 Nos
Filling of log sheet of each plant & to be maintained separetely
Record of testing of water shall be maintained daily before delivers time of water
Collection of chlorine/bleaching powder when required and accounting the consumption complete all as directed by Engr-In-charge.
Manning and operation of water supply installation at Jalapahar Pump House with a team of one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of pumping installation by tightening the gland of pump, replacing rubber coupling bushes, clearing the leakage of sluice valves, Non return valves by tightening gland and Cleaning of Foot valves etc. Change of Engine oil when required (Engine Oil will be issued by department). Cleaning of pump house surrounding like cutting of grass, dusting of Pump sets, Panel boards, DG set etc, for the following type/capacity of pump sets and other equipments complete all as specified and as directed :- (Srl Item No. 6.00 is continued as Srl Item No. 6.01 to 6.10)
Multi stage centrifugal pump set of 50 HP capacity -02 No
Altoch dozing system full set -01 Set
Overhead RCC Reservoir of 50000 Glns capacity -01 No at Pump House
Overhead Steel tank of 14500 Glns capacity -02 Nos at Pump House
Steel tank of 5000 Glns capacity -01 No at Pump House
All size of control valves at Pump House including distribution valves- 18 - Nos)
Diesel Engine generating set of capacity 62.5 KVA - 01 No
Filling of log sheet of each plant & to be maintained separetely
Record of testing of water shall be maintained daily before delivers time of water
Collection of chlorine/bleaching powder when required and accounting the consumption complete all as directed by Engr-In-charge.
Manning and operation of water supply installation at Jhora Pump House with a team of one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of pumping installation by tightening the gland of pump, replacing rubber coupling bushes, clearing the leakage of sluice valves, Non return valves by tightening gland and Cleaning of Foot valves etc. Change of Engine oil when required (Engine Oil will be issued by department). Cleaning of pump house surrounding like cutting of grass, dusting of Pump sets, Panel boards, DG set etc, for the following type/capacity of pump sets and other equipments complete all as specified and as directed :- (Srl Item No. 7.00 is continued as Srl Item No. 7.01 to 7.12)
Multi stage centrifugal pump set of 75 HP capacity -03 set
Altoch dozing system full set -01 Set
LT distribution panel board -3 Nos,
APFC Pannel Bd - 01 No
Underground RCC Reservoir of 50000 Glns capacity -02 No at Pump House and 01 No at source
Pressure filter of capacity 35000 Ltrs per Hour - 01 No
All size of control valves at Pump House including distribution valves- 12 - Nos
Diesel Engine generating set of capacity 160 KVA - 01 No
Daily vigilence check at natural water source No 1 & 2 and 01 No Underground RCC Reservoir of capacity 50000 Glns
Filling of log sheet of each plant & to be maintained separetely
Record of testing of water shall be maintained daily before delivers time of water
Collection of chlorine/bleaching powder when required and accounting the consumption complete all as directed by Engr-In-charge.
Manning and operation of water supply installation at 107 Pump House with a team of one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of pumping installation by tightening the gland of pump, replacing rubber coupling bushes, clearing the leakage of Gate Valves, Non return valves by tightening gland and Cleaning of Foot valves etc. Cleaning of pump house surrounding like cutting of grass, dusting of Pump sets, Pannel boards etc, for the following type/capacity of pump sets and other equipments complete all as specified and as directed :- (Srl Item No. 8.00 is continued as Srl Item No. 8.01 to 8.08)
Centrifugal pump set of 5 HP capacity -02 set and 3 HP - 01 No
LT distribution panel board -01 No,
Altoch dozing system full set -01 Set
Underground RCC Reservoir of 10000 Glns capacity -02 Nos
All size of control valves at Pump House including distribution valves- 8 - Nos)
Filling of log sheet of each plant & to be maintained separetely
Record of testing of water shall be maintained daily before delivers time of water
Collection of chlorine/bleaching powder when required and accounting the consumption complete all as directed by Engr-In-charge.
Manning and operation of water supply installation at Kalimata Pump House with a team of one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including periodical maintenance of pumping installation by tightening the gland of pump, replacing rubber coupling bushes, clearing the leakage of Gate Valves, Non return valves by tightening gland and Cleaning of Foot valves etc. Cleaning of pump house surrounding like cutting of grass, dusting of Pump sets, Pannel boards etc, for the following type/capacity of pump sets and other equipments complete all as specified and as directed :- (Srl Item No. 9.00 is continued as Srl Item No. 9.01 to 9.08)
Centrifugal pump set of 5 HP capacity - 01 No
LT distribution panel board -01 No,
Altoch dozing system full set -01 Set
Steel tank 30000 Glns capacity- 01 No and 9000 Glns capacity -01 Nos
All size of control valves at Pump House including distribution valves- 15 - Nos
Filling of log sheet of each plant & to be maintained separetely
Record of testing of water shall be maintained daily before delivers time of water
Collection of chlorine/bleaching powder when required and accounting the consumption complete all as specified and directed by Engr-In-charge.
Manning and operation of valves in Supply Mains at differnt locations at Jalapahar & Katapahar area with one FGM (Valveman) in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including repairing of sluice valve leakage by replacing gland packing/tightening valve collar bush, repairing of minor leakage in supply mains, confirming flow of water and supply of adequate water to the service reservoirs complete all specified and ditected.
Manning and operation of valves in Supply Mains at differnt locations at Lebong area with one FGM (Valveman) in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including repairing of sluice valve leakage by replacing gland packing/tightening valve collar bush, repairing of minor leakage in supply mains, confirming flow of water and supply of adequate water to the service reservoirs complete all specified and ditected.
Manning and operation of Electric supply installation at Station HQ Substation with one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including daily maintanance, entry of logbook, POL register, refilling of water & coolant in radiator, cleaning of sub-station surrounding like cutting of grass, dusting of DG sets, Pannel boards etc, for the following type/capacity of installations and other equipments complete all as specified and as directed :- (Srl Item No. 12.00 is continued as Srl Item No. 12.01 to 12.02)
Diesel Engine generating set of capacity 62.5 KVA - 01 No.
LT Control Panel 400A - 01
Manning and operation of oil fired incinerator installed at 163 MH with one FGM in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including cleaning of incinerator bldg surroundings, like grass cutting, dusting of electric panel, cleaning of burner, combustion chamber etc., filling of log sheet daily and maint register for running of incinerator and fuel consumption, collection of fuel as required for the following equipments complete all as specified and as directed :- (Srl Item No. 13.00 is continued as Srl Item No. 13.01 to 13.02)
Oil fired incinerator of burning capacity, 30-45 Kgs/Hrs
LT control panel.
Manning and operation for day to day maintenance of heating appliances, at Jalapahar and Katapahar area with one Refrigeration Mechanic in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including attending complaints of unserviceable geysers (repalacement of heating elements, indicator lamps, thermostat etc., repair/maint of electric point for geyser, replacement of plug top, taking down/refixing of Geyser etc) as detailed by JE E/M complete all as specified and as directed.
Manning and operation for day to day maintenance of heating appliances, at Lebong area with one Refrigeration Mechanic in one shift per day of 08 hours duration per shift on all working days incl Sundays & holidays including attending complaints of unserviceable geysers (repalacement of heating elements, indicator lamps, thermostat etc., repair/maint of electric point for geyser, replacement of plug top, taking down/refixing of Geyser etc) as detailed by JE E/M complete all as specified and as directed.
NOTES
Rate required to be quoted above items in BoQ keeping in mind of the following and as per tender documents:- (a) Wages, (b) ESI, (c ) EPF, (d) Contribution of Bonus, (e) LWC, (f) Over head charges etc
One No operator shall always be rpesent in each shft in each pump/power houses/sub station including sundays and holidays, in case of absent of any operator the penalty @ Rs 800.00 per shift shall be imposed on the conractor.
Qualification of trademen/operator shall be matriculation or SSC with 2 years experience /ITI pass and as specified in Tender Documents
Operator shall always be present in proper uniform of approved colour. Contractor shall be prepare duty roster of operator duty signed by al concerned and submitted to the concerned in Engr -in-Charge/office. This will be mandatory for payment of RAR
Operator shall always be present in proper uniform of approved colour. If operator found without uniform the penalty @ Rs 150.00 per shift shall be imposed on the contractor.
Age of FGM/trademen/operator shall not be less than 18 years and not more than 60 years.
Instructions to the Bidder/ Contractor
Tenderer are requested to attach the latest order of Central Govt/ State Govt/ Local body regarding minimum wages and statutary deductions regarding EPF & ESI etc
Contractor is required to quote upto two digits after decimal place otherwise it will be considared by rounding off two digits after decimal place in accordance with IS: 02 of 1960 (Revised 2016) of BIS.
The rate quoted for items of outsoursing shall not be less than minimum wages as notified by Govt of India/concerned state Govt/Local body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contributionto ESIC, contribution to bonus and LWC under respective heading/sub item(s). In case the rates quoted are less than the prevailing rates/instuctions under any headings , the bid will be treated as non-bonafied/ invalid & shall be disqualified and such bid will not be considered for acceptance. In such cases, the lowest bidder shall be determined from amongs the valid/bonafiede bids only.
The quotation with 'Nil' or 'Zero' consideration (Overhead/profit) shall be considered as 'Non-bonafide'.
In case two or more firms quote the same rates, the preference will be given to the firm based on their capability such as working capital, turn over of last 3 financial years ending and list of similar nature work completed in last 3 years.
The rate quoted by contractor shall deemed to be inclusive of all taxes, cess, levies as applicable including GST.
Note 1: (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
M/S TSHERING BHUTIA
Darjeeling Enterprises
M/S S. S CHETTRI AND SONS
HIRA SINGH
Janata Enterprises
GEETA CONSTRUCTION
RAI CONSTRUCTION
JALAPAHAR HARDWARE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .