Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹33.7 L+₹5.0 L (17.4%)Rejected-Finance BLOCK NO 7 BEHIND MALTI APTS NEAR SHIV DAIRY WANOWARI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹40.2 L+₹11.5 L (40.1%)Rejected-Finance | L3 | Rejected-Finance Not the lowest e-tenderer | |
| 4 | L4₹42.4 L+₹13.7 L (47.7%)Rejected-Finance | L4 | Rejected-Finance Not the lowest e-tenderer | |
| 5 | L5₹64.3 L+₹35.6 L (124.2%)Rejected-Finance | L5 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹42.8 L
EMD Value
₹85,500
Closing Date
5 Oct 2021, 6:00 pmClosed
Col Santosh Pandey CWE(A)Mumbai
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
ADDITION / ALTERATION TO FIRE FIGHTING SYSTEM OF VARIOUS BUILDING OF ARMY AREA UNDER GE WEST COLABA MUMBAI
2021_MES_469216_2
84046/W/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE WEST COLABA MUMBAI
Please Refer The Tender Documens
7 documents required · 7 mandatory
₹500
₹85,500
17 Dec 2021
14 Sept 2021
6 Oct 2021
14 Sept 2021
5 Oct 2021
23 Sept 2021
14 Sept 2021 - 28 Sept 2021
Amount
Supply, Installation, Testing, Aligning and proper leveling & commissioning of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft working parts (EN-8) mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 1620 LPM discharge , directly coupled to totally enclosed fan cooled squirrel cage A.C. induction motor of suitable capacity of operate on 3ph, 415V & 50 cyc A.C. with B class installations & both the pump & motor are to be Erected on common M.S. base plate, and required size MS channel suitable rigid foundation, nut bolt washer, coupling guards and anti vibration rubber pad and accessories including taking down of existing all as specified and directed. Make: Kirloskar/KSB/Mather & Platt.
Supply, Installation, Testing, Aligning and proper leveling & commissioning of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft working parts (EN-8) mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 2850 LPM discharge , directly coupled to totally enclosed fan cooled squirrel cage A.C. induction motor of suitable capacity of operate on 3ph, 415V & 50 cyc A.C. with B class installations & both the pump & motor are to be Erected on common M.S. base plate, and required size MS channel suitable rigid foundation, nut bolt washer, coupling guards and anti vibration rubber pad and accessories including taking down of existing all as specified and directed. Make: Kirloskar/KSB/Mather & Platt.
Supply, fix and jointing in repairs duly welded heavy grade MS ERW pipe with 100mm dia class 'C' conforming to IS 1239:2004 in trenches / wall / floor including all fittings, such as coupling, bends, elbow, and tee etc with two coats of synthetic enamel paint in red colour over red oxide primer for pipe and fire hydrant stand post with welding, screwing joint etc complete all as specified and directed by Engineer-in-Charge. Make : Jindal/Tata
Supply, fix and jointing in repairs duly welded heavy grade MS ERW pipe with 150mm dia class 'C' conforming to IS 1239:2004 in trenches / wall / floor including all fittings, such as coupling, bends, elbow, and tee etc with two coats of synthetic enamel paint in red colour over red oxide primer for pipe and fire hydrant stand post with welding, screwing joint etc complete all as specified and directed by Engineer-in-Charge. Make : Jindal/Tata
Supply, Installation, Testing & Commissioning of Stainer of size 150mm with necessary fittings, flanges, nut bolts etc. as per specification including taking down of existing all as directed. Details: The "Y" type Strainer shall have cast iron body conforming to IS210 FG 200. Perforated sheet shall be of brass or Stain less Steel 304. The Screen open area shall be minium four times cross sectional area at inlet. The Strainer shall be suitable for MIN. flow of 300 LPM. at 10kg/cm.sq pressure. The flanges shall be to IS1538. The nut bolts and washers shall be Galvanized confirming to IS1367. The pressure loss shall not be more than 0.5 kg/cm.sq. The Hydraulic Testing shall done at 21 kg/cm2 for the duration of Two hours. Make- Rapid Control / Emberland / Sant
Supply, Installation, Testing & Commissioning of Hydrant Valve with necessary fittings as per specification. Details: Hydrant valve shall be marked IS 5290 and shall have Double outlet having 75mm flanged inlet and complete set shall be made of Gunmetal. Oblique outlet female instantaneous type coupling having spring loaded lugs; internal parts shall be of copper or gunmetal. A cap (made of Gun metal) with chain shall be provided on the outlet of the valve, which have 63mm instantaneous pattern female coupling confirming and marked IS-903 including taking down of existing UNSV valves all as specified and directed . Make- 1. Kirloskar 2. Leader 3. Sant 4. Upadhyay 5. L & T
Supply, Installation, Testing & Commissioning of Hydrant Valve with necessary fittings as per specification. Details: Hydrant valve shall be marked IS 5290 and shall have single outlet having 75mm flanged inlet and complete set shall be made of Gunmetal. Oblique outlet female instantaneous type coupling having spring loaded lugs; internal parts shall be of copper or gunmetal. A cap (made of Gun metal) with chain shall be provided on the outlet of the valve, which have 63mm instantaneous pattern female coupling confirming and marked IS-903 including taking down of existing UNSV valves all as specified and directd . Make- 1. Kirloskar 2. Leader 3. Sant 4. Upadhyay 5. L & T
Supply, Installation, Testing & Commissioning of yard Hydrant stand post of size 80mm dia MS/GI both end flanged type and 1.5 Mtr height with necessary fittings as per specification including taking down of existing UNSV all as specified and directed . Make- Minimax / Firex / Safex
Supply, Installation, Testing & Commissioning of N.R.V. butterfly valve type of size 150mm with necessary fittings, flangs, nut bolts etc. as per specification including taking down of existing UNSV valves as specified . Details: Non-return valves shall be cast iron spring action swing check type. An arrow mark in the direction of flow shall be marked on the body of the valve. The valve shall bear IS:5312 certification. The valve shall be of cast iron body and cover. The internal flap in the direction of water shall be of cast iron and hinged by a hinge pin of high tensile brass or stainless steel Cast iron parts shall be conform to 13:210/70, grade 200/260 type. Make-(a) L&T (b) AUDCO (c) Upadhya (d) Kirloskar
Supply & Fix in repairs valve reflux cast iton (NRV) with by pass arrangement supplied installed complete of size 100mm dia including filling properly the gland packing kit complete all as specified and directed by Engineer-in-Charge. Make :- Kirloskar
Supply, Installation, Testing & Commissioning of Pressure switch universal type with accessories complete including taking down all as specified and directed . Make- Siemens / Honeywell / Danfoss / Schneider / Rapid Control
Supply, Installation, Testing & Commissioning of flow switch of size 150mm dia type with accessories complete including taking down all as specified and directed . Make- Siemens / Honeywell / Danfoss / Schneider / Rapid Control
Supplying, fixing fire hose cabinet box of size 1200x900x715mm made out from 16 guage MS sheet with double leafed glazed shutters (glaged with 4mm thick glass) including provision for two length of canvas hose, branch pipe fire hose and nozzle, fireman axe, first aid hose and single outlet landing valve complete including taking down existing box all as specified and directed at site. Make- EXFLAME/CEASE FIRE/VIJAY ENGG/WINCO
Supply, Installation, Testing & Commissioning of Double door Hose box with painting with necessary fittings as per specification. Details: Fire Hose Cabinets shall be fabricated from 3mm MS Sheet with locking arrangement of size of hose cabinet shall be 800 X 600 X 250mm the painting of the hose cabinet shall be as described earlier. Each hose cabinet shall accommodet Hydrant valve. Two nos of 15 Mtr. long hosepipes & One no. of branch pipe with nozzle. The Fire Hose cabinet will have the legend "FIRE HOSE" painted prominently in the graphic style including taking down existing box all as specified and as directed . Make- EXFLAME/CEASE FIRE/VIJAY ENGG/WINCO
Supply, Installation, Testing & Commissioning of Hose real drum with Hose pipes including taking down existing real . The hose pipes shall be externally elastomeric coated all synthetic jacketed, rubberized fabric reinforced rubber lined (RRL). Non-percolating, flexible fires fighting hose, delivery resistant to liquids, chemical abrasion & heat, having 38 Kg/cm2 burst pressure, 22 Kg/cm2 proof pressure, 14 kg/cm2 working pressure, bearing IS:636 type 'A' mark, fitted with gunmetal instantaneous pattern heavy duty male & female delivery heavy duty hose coupling, bearing IS:903 mark. Binded by copper wire with necessary fittings as per specification. Make- Minimax / Safex / Superex
Supply, Installation, Testing & Commissioning of CP Hose pipes of size 15 RM The hose pipes shall be externally elastomeric coated all synthetic jacketed, rubberized fabric reinforced rubber lined (RRL). Non-percolating, flexible fires fighting hose, delivery resistant to liquids, chemical abrasion & heat, having 38 Kg/cm2 burst pressure, 22 Kg/cm2 proof pressure, 14 kg/cm2 working pressure, bearing IS:636 type 'A' mark, fitted with gunmetal instantaneous pattern heavy duty male & female delivery heavy duty hose coupling, bearing IS:903 mark. Binded by copper wire with necessary fittings as per specification. Make- Dunlop / Cosmos / Jayshree/EXFLAME/CEASE FIRE/VIJAY ENGG
Supply, Installation, Testing & Commissioning of Fire Brigade Inlet Unit 4way with necessary fittings 150mm dia including taking down old unit . Fire Brigade Inlet for Tank filling by Fire Brigade shall be four way with flanged gun metal instantaneous male inlet coupling connection for connection with Fire Brigade vhicles or Tanker. The inlets shall be provided with ABS Quality by Plastic Blank caps with chain and arrangemet for attaching the blank cap & chain to the Fire Brigade inlet as per specification. Make-Minimax / Safex / Superex
Supply, Installation, Testing & Commissioning of A.R.V of size 32mm with necessary fittings, flanges, nut bolts etc. as per specification including taking down existing . Details: Air valves shall be provided at all points in the piping system to enable expelling entrapped air when filling or allowing in take of air when emptying the system air release valve shall be installed at top of risers with isolation valve. Isolation valve shall be marked IS 778 or ball valve. Make: Zoloto/ ZIP/ Leader
Supply & Fix CI Sluice valve with flanged ends, cast iron body flanged and drilled end non rising type. HT bronze spindle with nuts, class PN-1.6 suitable for 100 mm bore as per IS 14826, ISI marked including all joints with rubber or fibre board, bolts and nuts, washers etc complete including taking down existing all as specified and directed by Engineer-in-Charge. Make-1 Leader 2 Kirloskar 3 Upadhya 4 L&T 5 AUDCO 6 Bir
Supply & Fix CI Sluice valve with flanged ends, cast iron body flanged and drilled end non rising type. HT bronze spindle with nuts, class PN-1.6 suitable for 150 mm bore as per IS 14826, ISI marked including all joints with rubber or fibre board, bolts and nuts, washers etc complete including taking down existing all as specified and directed by Engineer-in-Charge. Make-1 Leader 2 Kirloskar 3 Upadhya 4 L&T 5 AUDCO 6 Bir
Supply, Fix and testing complete for 20 mm dia Gun Metal Gate Valve as per site condition including taking down existing all as specified and as directed . Make: Zoloto/ ZIP/ Leader
Supply, Installation, Testing & Commissioning of GM Short Universal Branch pipe as per specification. Details: Branch pipe shall be constructed from Gunmetal alloy as per IS:318, LTB 2 grade, or aluminium alloy and finished to a smooth polish. 63mm dia instantaneous type inlet at one end and secound shall have threading. The nozzle shall be of gunmetal, 20mm internal dia. The screwed inlet fitted to the branch pipe. The branch pipe shall be marked IS:903 including taking down existing all specified
M & L for valve chamber of any size, type and construction of brick masonry valve chamber of size 0.90m x 0.90m x 0.90m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 10mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth wotk in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified.
M & L for Point wiring complete with copper conductor, multi-standard PVC insulated and un sheathed 2.5 sqmm cable, 1100 volts grade, conforming to IS-694-I in and including PVC casing caping with all fixing accessories on wall/ceiling/floor/roof with PVC moulded terminal boxes for mounting fixtures duly earthed with one ran of 16 SWG coper earth wire of 2.5 Sqmm all as specified for the One 3 pin 15 Amps switch socket outlet on independent board all as specified and directed .
M&L for switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal type all as specified and directed .
Supply & Fix foot valve CI with ISI marked heavy duty conforming to IS 4038 of rubber ball lock type including all accessories regular little rubber gasket, nut & bolts, washers etc complete of size 150mm dia complete all as specified and directed at site. Make :- Kirloskar
M & L for cement concrete in foundations, filling and mass concrete (PCC) in CM of (1:2:4) with type B2 using 40mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanised earth plate electrode 60cmx60cmx6.15mm thick, burried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI strip 32x6 mm as earthing lead by means bolts and nuts check nuts and washers galvanised iron and connected to main switch board including watering arrangement with PCC chamber, MS funner with wire mesh CI cover with frame etc including necessary excavation in any type of strata, returning filling removal of soil outside MD land filling of charcoal and salt complete includiong taking out existing all as specified and directed and testing on completion all as directed.
Supply & Fix earth continuty conductor fixed to wall/surface or recess or burried in ground or any situation for loop earthing by 25 X 4 mm GI strip complete including taking down old all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. in soft/loose soil n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
M & L for road cutting in Bituminous road/hardstanding for laying cables/pipes and making good after necessary returning & filling all as specified & directed.(Returning filling shall be measured & paid seperately)
Returning, filling in including spreading levelling, watering and well ramming in layers not exc 25 cm deep as in soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed by Engineer-in-Charge.
Supply & Lay cable PVC insulated armoured with ISI marked and PVC sheathed LT 1100 Volts grade with aluminium conductor including saddeling if aluminium over the surface/wall/floor in proper alignment with proper cable Lugs of suitable size at site with the cable size 35 Sqmm X 3.5 Corecomplete including taking down existing all as specified and directed. Make : polycab/KEI/HAVELLS
Supply & Lay cable PVC insulated armoured with ISI marked and PVC sheathed LT 1100 Volts grade with aluminium conductor including saddeling if aluminium over the surface/wall/floor in proper alignment with proper cable Lugs of suitable size at site with the cable size 95 Sqmm X 3.5 Core complete including taking down existing all as specified and directed. Make : polycab/KEI/HAVELLS
Material and labour GI tubing 50 mm dia light grade galvanized for cable protection and fixing of post top lantern with all connecting items (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole complete including taking down existing all as specified and directed. Make : Tata /jindal/swastik
Supply and Fixing of New fire alarm panel Digital type with PA system with audio visual indication suitable for operating on 230 V AC / 24 V DC supply with solid state electric having addressable type one loop per card complete with following details: a) Visual zone indicators to which fire has emerged. b) 2 Sounder Circuits Device and 20 Fire Zone. c) Acknowledgement indication incorporating the following : - I) Fire - Indicators- Dual Red. ii) Fault indication. iii) AC battery failure indicators. iv) Blow fuse indicators (AC & DC) v) Built in hooter electronic. vi) AC pilot indicators. vii) Open and short circuit fault indications viii) The reset push button. ix) Acknowledge reset and test device. x) Width 12 V x 7.2 AH battery 2 Nos. Make: APOLLO / GE –EDWARD / HONEYWELL / SIEMENS/ MORLEY COOPER / NOTIFIER /RAVEL
Supply , Commissioning and Testing of addressable type combine manual call points & Electronic dual tone sounder operating with PA system of every floor with break glass type weather proof of standard size metal hammers and chain mounted on wall at the height of 2 meter approximate from the ground complete including taking down existing all as specified and directed. Make: APOLLO / GE –EDWARD / HONEYWELL / SIEMENS/ MORLEY COOPER / NOTIFIER /RAVEL
Supply, Commissioning and Testing of Multisensor Smoke with Heat detector addressable type , automatic reset type, approved by loss, prevention corporation bureau complete all including taking down existing as specified and directed. Make: APOLLO / GE –EDWARD / HONEYWELL / SIEMENS/ MORLEY COOPER / NOTIFIER /RAVEL
Supply of junction boxes for detector complete including taking down existing all as specified and directed. Make: APOLLO / GE –EDWARD / HONEYWELL / SIEMENS/ MORLEY COOPER / NOTIFIER /RAVEL
Supply, testing & commissioning of 1.5 Sqmm Solid Copper 6 core armored cable including shadling/cable gland etc.including taking down existing
Supply, fixing and Testing complete of pipe suports for all type of pipes including hangers, fastners, elbows ,bend,tees etc including taking down existing all as specified and directed.
Trinity Engineers
M/S GLOBAL FIRE PROTECTION SYSTEM
Shetty Construction Co
SD INFRA And MEP Services Pvt. Ltd.
cooltech engineering services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .