| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC 630 MAIN ROAD BABINA CANTT 284401 TESIL DISTT JHANSI UP | BABINA CANTT | JHANSI | UP | 284401 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.2 L+₹25,377.73 (1.82%)Rejected-Finance HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹14.3 L+₹37,989.83 (2.72%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹14.4 L+₹41,469.58 (2.97%)Rejected-Finance | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹14.4 L+₹41,830.40 (2.99%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
₹17.9 L
EMD Value
₹35,780
Closing Date
30 Nov 2023, 6:00 pmClosed
CWE JHANSI
HQ CWE JHANSI
PROVN OF GUARD ROOM WITH BATHROOM AND TOILET FOR 02 X HAV AND 06 X OR AT ZONE-3 SM-I UNDER GE BABINA CANTT
2023_MES_626720_1
CWE/JHA/BAB/TOKEN/90 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
BABINA
As per tender documents
8 documents required · 8 mandatory
₹500
GE BABINA
₹35,780
Yes
27 Feb 2024
3 Nov 2023
2 Dec 2023
3 Nov 2023
30 Nov 2023
18 Nov 2023
Amount
Surface dressing n.exc 15 cm thicknes in hard and dense soil complete all as specified and directed.
Excavating in trenches in hard and dense soil , not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning, filling in hard and dense soil in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified and directed
M&L for form work to sides of square or rectangular columns, pillars, posts and struts for rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surfaces of concrete complete all as specified and directed.
Material and labour for form work to soffits of suspended slabs such as roof slabs floor slabs, landing and similar works not exceeding 200mm thick finishing concrete surfaces fair and even complete all as specified and directed
M&L for form work to edges of concrete flat, opening in concrete walls and roofs not exceeding 20 cm wide and sides of RCC/PCC bands and similar works exceeding 10cm but n.exc 20cm wide complete all as specified and directed
M&L, old size Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed
M&L, old size Brick work with sub class ;B; bricks old size half brick thickstraight or covered on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for form work to chullah, chajjas, troughs and similar items including edges, fair finished complete all as specified and directed
M&L for RCC M-20 (using 20 mm graded stone aggregates) in chajjas (reinforcement to be measured separately) complete all as specified and directed
M&L RCC M-20 (using 20 mm graded stone aggregates) in slabs supported on complete all as specified and directed. (reinforcement to be measured separately).
M&L RCC M-20 (using 20 mm graded stone aggregates) in foundations, footing, plinth beams, bases for columns and mass concrete complete all as specified and directed. (reinforcement to be measured separately).
M&L RCC M-20 (using 20 mm graded stone aggregates) in columns, pillars, posts & struts complete all as specified and directed. (reinforcement to be measured separately).
M&L RCC M-20 (using 20 mm graded stone aggregates) in roof beams,cantilevers,lintels,chajja etc complete all as specified and directed.
M&L for TMT bars 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed not less than 0.9 mm dia or securing with clips quality complete all as specified and directed
M&L for TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed not less than 0.9 mm dia or securing with clips quality complete all as specified and directed
M&L for TMT bars 5mm dia and overupto and including 10mm dia stirrups spacers and binder, cut to length, bent to shape required including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed not less than 0.9 mm dia or securing with clips quality complete all as specified and directed
M&L for providing precast cement concrete type B-1,1:2:4 (20mm graded aggregate) as in cover slabs ,shelves and similar articles all as specified ,set in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in cm 1:4 mixed with water proofing compound 2% by weight of cement and finish the surfaces fair and even without using extra cement (WPC shall be measured separately) complete all as specified and directed
M&L for rendering 10 mm thick cement plaster 1:6 on brick surfaces other than fair face finished fair and even complete all as specified and directed
M&L for rendering 5 mm thick cement plaster in cm 1:3 on ceiling Finishing the surfaces fair and even complete all as specified and directed
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls over a coat of primer and apply two coats of OBD over a coat of putty complete all as specified and directed.
M&L for Preparing new decorated plastered or unplastered surfaces of ceiling and applying two coats of white wash complete all as specified.
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over & including a coat of primer complete all as specified and directed
M&L hard core of base n.exc 63mm of broken stone or bolder, deposited, spread and leveled in layers n exc. 15cm thick watered and rammed to a true surface complete all as specified and directed
M&L for cement concrete 75 mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base complete all as specified and directed.
M&L for cement concrete flooring ,25 mm thick PCC 1:2:4 type B-1 using 20mm graded aggregate finished even and rough to receive tiles complete all as specified and directed
M&L for Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.18sqm but not exc 0.36 sqm, in dado/Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match set in CM 1:4 as in backing coat to floor etc complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed ceramic tiles of size 300x450x 7-8 mm thick on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed,jointed in white/coloured cement to match set in CM 1:4 as in backing coat complete all as specified and as directed
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection complete all as specified and as directed
S&F for vitreous china wash basin white flat back size 630x450 mm including brackets,cutting for and pinning in ends of brackets connection to supply and waste pipe fixed in concrete type( B-1 )1:2:4 and complete all as specified and as directed
S&F for cast iron nahani trap100mm dia including grating, jointing to waste pipe complete all as specified and directed
S&F for pillar tap cast capper alloy with capstan head, fancy type chromium plated screwed iron pipe 15 mm dia and complete all as specified and as directed
Supply and fixing cast copper bib taps 15 mm bore dia, fancy type chromium plated with crutch or butterfly handles, screwed down, suitable for 15 mm bore GI pipe complete all as specified and directed
Supply and fixing stop cock 15 mm bore dia cast copper alloy fancy type,chromium plated with capstan head screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipes and complete all as specified and as directed
Supplyand fixing 32 mm dia waste fitting brass chromium plated for wash hand basin couth long screwed sharks and fly nuts flange and embedded in red lead cement and other end fixed and complete all as specified and as directed.
Supply and fixing tubular towel rail brass chromium plated 20 mm dia D type 60 cms long and complete all as specified and as directed
M&L for galvanized steel water tubing 15 mm dia medium grade including all fitting laid in floor/walls & ceiling and complete all as specified and as directed
M&L for galvanized steel water tubing 20 mm dia with all fitting medium grade including all fitting laid in floor/walls & ceiling and complete all as specified and as directed
M&L for galvanized steel water tubing 25 mm dia with all fitting medium grade laid in floor/walls & ceiling as specified and directed.
PVC connection suitable for 15 mm bore GI pipe, 450 mm long of pressure rating 6 kg/sq cms fixed complete including one GI unions at each end and complete all as specified and as directed
M&L 1000 ltrs rotational moulded polyethylene water storage tank (cyclindrical vertical with closed top) fixed in position and complete all as specified and as directed
Supply and fixing ball brass valves 20 mm bore dia high pressure with polythene float and fly nut complete screwed iron pipe or brass ferrule complete all as specified and directed
S&F, Gun metal Glabe or gate valves with iron wheel head screwed both ends for pipe, 20mm bore dia of pipe complete all as specified and directed
S&F PVC valve less, symphonic action type, flushing cistern 10 liters capacity low level white with inlet ,ball valve ,float and handle including bracket and any description complete all as specified and directed
S&F for flush pipe of polyethylene of low or high density PVC, 32 mm dia and complete all as specified and as directed
S&F for water closet vitreous china squatting pan” pedestal pattern” size 580x440mm white with integral foot rest complete including provision of lime concrete all as Specified including seat cover complete all as specified and directed.
S&F for Chromium plated shower roses with or without swivel joints 125mm size complete all as specified and directed.
S&F, angle cock, cast copper alloy, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe 15mm bore complete all as specified and directed.
S&F Pressed steel frames for doors of size 125x60 mm with one or more rebates including necessary PCC1;4;8 filling, fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
Supplied and fixed 35 mm thick IInd class hardwood plain, framed panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered plywood commercial type 9 mm thick complete all as specified and directed.
M&L IInd class hard wood 35 mm thick glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members as speciifed in SSR Part I, Section-8, clause 8.20(a), supplied and fitted to chowkhats complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top &bottom rails. MS framed shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail &bottom rail on either side & as gap insert for tap rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement supplied & fixing in the frame at site complete all as specified and directed.
Supplied and fixed butt hinges, extruded aluminium alloy with galvanized mild steel hinge bin, anodized and fixed type C-22 100mm size complete all as specified and directed.
Supplied and fixed 100 mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
Supplied and fixed 200 mm size aluminium anodized barrel tower bolt of extruded section complete all as specified and directed.
Supplied and fixed aluminium alloy, anodized sliding door bolt with hasp and staple bolt type and fixing clips of sheets, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy, length 300 mm complete all as specified and directed.
Material and labour for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring fixed in floors, length of cover plate 150 complete all as specified and directed.
S&F for 300mm,brass ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cms in width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
M&L Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, with glazing bars complete all as specified and directed.
M&L Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, without glazing bars complete all as specified and directed.
M&L Mild steel bearing bars, window guard bars, plain, let in and fixed independently in wooden frames, conforming to Fe-410-0 or Fe 310-0 complete all as specified and directed.
M&L Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
M&L Figured glass, pin head type 3mm thick and glazing with oil putty in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
Supply and fixing galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average sidth of aperture 1.40 mm complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description over 10 cms in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F,110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F,110mm bore PVC (SWR) bends of any radius complete all as specified and directed.
Cutting into existing manholes for connecting 100 mm dia PVC pipe new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.
M&L 100mm dia salt glazed stoneware drain pipe laid in trenches and jointed in neat cement slurry complete all as specified and directed.
M&L 150mm dia salt glazed stoneware drain pipe laid in trenches and jointed in neat cement slurry complete all as specified and directed.
M&L for concrete bed to drain pipe (100 mm dia) in cement concrete 1:4:8 type D2 including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for concrete bed to drain 150mm pipe in cement concrete 1:4:8 type D2 including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L Treating the bottom and sides of excavation at the rate of 5 liters of emulsion per sqm of surface area complete all as specified and directed
M&L Treating the backfill in contact with foundation at the rate of 7.5 liters of emulsion per Sqm of vertical surface ( Area of sub structure in contact with backfill to be measured ) complete all as specified and directed.
M&L Treating the top surface of filled earth at the rate of 5 liters of emulsion per Sqm of surface area complete all as specified and directed
M&L Treating the soil under plinth protection at the rate of 5 liter of emulsion per sqm of surface area complete all as specified and directed.
M&L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per meter of the perimeter wall complete all as specified and directed
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed , including watering, consolidating and dressing complete all as specified and directed
M&L water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100mm microne HMHDPE outer flim 20 micron each having thickness 3 mm weight not less than 3kg/Sqm with 100mm overlap laid as per manuacturer's instructions and complete all as specified and directed with following course of description below:- (a) 1st coat applying bitumen primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated. (b) 2nd coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm. (c) 3rd course ie. laying of APP Based modified membrane described herein before with 100mm overlap in longitudinal direction and 150mm in transverse direction, all joints and changes in all direction should be covered covered with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. (d) Applying one coat of bituminious aluminium paint @ 0.20 Kg Per Sqm over APP membrane,
M&L for rendering 10mm thick fair finished using cement mortar (1:4) with WPC on flat roof slab complete all as specified and directed.
S&F in repair CP Brass soap dish fixed to wall with cp brass screws etc complete all as specified and as directed.
S&F in repair stainless steel curtain rod of 25 mm dia curtain with stainless steel end knob ,suitable for curtain rod 25 mm dia complete all as specified and directed.
Supply only PVC waste pipe with 32 mm bore and 65 cm long with cap complete all as specified and directed.
M & L for concealed point wiring complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green multi stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed for the following :-
One light point controlled by one switch
One fan point controlled by one switch & regulator.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per Ser item No 97 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S & F delux Fan Regulator electronic rotary, step type 240 Volt 50 Hz, complete all as specified and directed.
S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified and directed.
S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified and directed.
S&F ceiling rose,surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S&F for sub main wiring with PVC insulated, unsheathed 2 single core cable 1100 volts grade with copper conductor of size 6.0 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 6.0 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately.
S & F Regid non-metallic PVC conduit not less than 25 dia (external) ISI marked concealed and including cutting necessary chases concealed incl of all acces and all fitting such as Tees ,bend blbow reducer bell mouth , tube end and fixing accessories such as coupler locknut saddle pipe, hook etc complete all as specified and as directed
S&F TPN DB-DPX 125 MCCB DBs 4 way DOUBLE door ip 43 with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as out going no of modules DPX 125+12, concealed on wall Complete all as specified and as directed.
Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 100 Amp 100% ICU complete all as specified and as directed.
S&F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed .
S&F MCB single pole and neutral 40 Amp/63 Amp 240 V ,10KA , 'C' series, complete all as specified and as directed with copper lugs complete all as specified and directed.
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'C' series,complete all as specified and as directed
Supply and fixing in repair 20 W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 28watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed.
Supply and fix LED 35W street light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminium IP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtr length with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesingle core PVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and directed.
Supply and laying XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 X 4 sq. mm complete all as specified and directed.
Supply and Fixing Exhaust fans AC single phase 230/240V of size 300 mm sweep, 1400 RPM with louvre complete including with all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessary fixing arrangement such as fastener bolts, nuts, washers etc, of appropriate size all as specified and as directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 225 CFM with 30 watt consumption. Five star rated with brushless direct current motor (BLDC) with 350 rpm complete all as specified and as directed
Excavation in trenches in any type of soil not exe 1.5 mtrs wide and not exe 1.5 mtr in depth for laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
Returning fitting in soft/loose soil, including spreading levelling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated soils to a distance n.exc. 50 mtrs and depsiting where directed at a level n.exc. 1.5 above the starting point complee all as specified and directed
Supply laying dry clean river sand free from sharp materials, unscreened filling in trenches around under ground cables for cushioning complete all as specified and directed.
Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete all as specified and directed.
M&L pipe galvanised iron of size 50 mm dia, light grade ISI marked, complete with fittings laid in trenches/ fixed with poles etc as protection to cables complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
m/s bobby enterprises
M/s Ravi Traders
Shree Jee Associates
FTH Traders
M/S Kharya Associates
HARNAM SINGH ANIL SINGH
Ms Vinay constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .