Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹43.0 L+₹1.1 L (2.71%)Rejected-Finance | L2 | Rejected-Finance Not Lowest bidder | |
| 3 | L3₹45.9 L+₹4.0 L (9.51%)Rejected-Finance 35 PATHAK PARA ROAD FLAT NO 32C 3RD FLOOR SHANTINEER APARTMENT BEHALA KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance Not Lowest bidder | |
| 4 | L4₹46.6 L+₹4.7 L (11.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest bidder | |
| 5 | L5₹46.7 L+₹4.9 L (11.6%)Rejected-Finance 10 UDAY SHANKAR SARANI SEVOKE ROAD SILIGURI DIST DARJEELING WB PIN 734 001 | JALPAIGURI | WEST BENGAL | 734001 | L5 | Rejected-Finance Not Lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Jun 2021, 6:00 pmClosed
GE Bengdubi
Bengdubi Military Station, PO-Bengdubi,Dist-Darjeeling, Pin 734424
PROVN OF STORE ROOM (WOODEN AND STEEL FURNITURE) SENTRY POST IRON GRILL AROUND SYNTEX TANK MONKEY TRAP WIRE MESH LED SECURITY LIGHTS PVC PANELING AND LIGHTENING CONDUCTOR AT BSO OFFICE AND CERTAIN UINTS UNDER AGE BRI AT BENGDUBI MIL STN
2021_MES_438937_2
GE/BENG/04 OF 2021-22
Open Tender
Civil Works
Works
240 days
Bengdubi
MES Enlisted/ Un-enlisted contractor of Class D and above with category a(i)
8 documents required · 8 mandatory
₹500
GE Bengdubi
₹80,000
Yes
15 Jul 2021
11 Jun 2021
2 Jul 2021
11 Jun 2021
30 Jun 2021
18 Jun 2021
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Surface dressing n exc 15 cm deep in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and 1.5 mtr depth for foundation etc, not exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Ditto all as per Item no 2.00 here-in-before but exceeding 1.5mtr not exceeding 3.0mtr deep complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Removing excavated material (soil) to a distance exc 50m but n.exc. 100m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (Design Mix) using 20 mm graded crushed stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 12.5 mm graded crushed stone aggregate in Columns, pillars, piers, posts etc all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 12.5 mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span etc all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 20mm graded crushed stone aggregate Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 12.5 mm graded crushed stone aggregate in Chajja etc all as specified and directed.
Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick in rough finish of concrete surface etc., complete all as specified and directed.
Use & Waste of formwork to chullah hoods, chajjas, troughs and similar items including edges, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide, rough finished surface of concrete complete all as specified and directed.
M&L for Fly ash brick work with old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 10 mm dia & over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 8 mm dia, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Ditto all as per item No. 21.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed.
S&F 1.25mm thick rolling shutter without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with gear operated type with bevel gear box and crank handle all as specified and directed.
S&F safety lever locks mild steel with 4 levers for rolling shutter all as specified and directed.
S&F ball bearing for rolling shutter all as specified and directed.
S&F Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming Fe-410W (GdeE-250) quality B complete complete all as specified.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F for Framed work such for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
S&F for Expanded metal, not exceeding 4kg/sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, devetailed or welded complete all as specified and directed.
Ditto all as per item No. 32.00 here-in-before but without glazing bars (for mosquito proof shutter )
S&F in steel ventilator with top hung shutter including hinges steel peg staycomplete all as specified and directed.
S&F roof trusses (farmed), trusses purlins, crane gantries, rails and fastenings and heavy bracket framing MS angle/MS tubes medium grade as in truss, purlin, rafters, post etc fixed with and including angle cleat , MS plate etc including necessary welding, fittings etc Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
S&F Pre-painted coloured trapezoidal profiled Galvalume / Zincalume sheet with min thickness of 0.50 mm TCT confirming to IS-513 (AZ-150 GSM, AI Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof covering/cladding to wall fixed with self tapping screws colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron poyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling self tapping fastener (12-14 x 55 with EPDM seals) complete as specified etc complete all as specified and directed.
S&F Pre-painted coloured plain Galvalume / Zincalume sheet with min thickness of 0.60 mm TCT confirming to IS-513 (AZ-150 GSM, AI Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof ridge colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron poyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling self tapping fastener (12-14 x 55 with EPDM seals) complete as specified etc complete all as specified and directed.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in subbase/flooring complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L for 16-20mm thick machine cut kota stone slab in floors etc. over screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Ditto all as per item No. 41.00 here-in-before but in vertical surfaces such as dado/skirting including backing coat 10mm thick cement mortar (1:4) complete all as specified and directed.
M&L for Non Skid ceramic tiles (coloured) 7 to 8 mm thick, (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match etc., including screed bed mortar 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protections, finished even and smooth w/o using extra cement with joints 10 mm wide and in full depth at corners and @ 3.0 m c/c filled with mastic mortar complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth without using extra cement etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth without using extra cement etc complete all as specified and as directed
M&L for rendering 20 mm thick in CM (1:4) on other than fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) complete all as specified and as directed
M&L rendering 5mm thick in cement mortar (1:3) on ceiling, soffits of chajjas fins etc complete as specified and directed.
M&L for prepration of newly plastered surfaces of walls and applying two coat of oil bound distemper over chalk whiting etc complete all as specified and directed.
M&L for newly plastered surface of wall appying two coat of cement base paint over one coat of alkali resistant priming paint etc., complete all as specified and directed.
S&F 3mm thick plain glass of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares n exc 0.50 sqm in each pane complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described for two coat of Synthtic Enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparing new plastered on wall and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered on ceiling and applying three coats of white wash complete all as specified and directed.
Cutting opening in cement concrete walls (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc. complete all as specified and directed.
S&F PVC wall paneling frame made out of electric resistance welded semi-bright square steel tube of size 25mm x 25mm x 16 SWG, size laid both ways not less than 600mm C/C both ways with two coat of synthetic enamel paint over a coat of red oxide zinc on frame shall be fixed to walls by means of wooden/plastic rawel plugs or gut ties PVC wall panelling shall be laminated plastic section SPUF-144 of size 250mm x 8mm with distance between the supporting ribs not exceeding 19mm including necessary cutting for electrical fitting as per site requirement complete all as specified and directed. (Makle:- Cactus, Sintex, Plasopan)
M&L for preparation of new steel sruface of any description, n.exc. 10 cm in width or girth, not otherwise described for two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Spreading and leveling in layers n.exe. 25 cm thick well ramming including watering for earth filling quantity obtained from item No 02 & 03 approved soil by GE without bushes and etc.
SCHEDULE 'A' PART-II (E/M WORKS)
M&L for concealed point wiring One light point/one fan/light/exjaust/bell point controlled by one switch with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface all as specified and directed.
All as per item No 62.00 here-in-before but One 3 pin socket outlet, 5 Amp on independent board all as specified and directed.
All as per item No 62.00 here-in-before but One 3 pin socket outlet, 5 Amp on same board all as specified and directed.
S&F Switch piano, flush button type, single pole, one way 6 Amp, 230 volt complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amp complete all as specified and directed.
S&F switch socket outlet combination 2 in 1, 5 amp, flush piano universal type controlled by one switch conforming to IS complete all as specified and as directed.
S&F ceiling rose surface bakelite three terminals complete all as specified and as directed.
S&F LED Tube Light luminaries with high performance LED with driver 1 x 18W (4 Feet long, Cool day/Warm white) complete all as specified and directed. Make:- CG Cat Part No -LCTL-18-CDL or equivalent model of Philips / Bajaj /Surya
S&F Sheet metal enclosure for MCB, DBs, phosphatised, power coated, single door single pole & Neutral 4 way 240 volt with 200 Amps bus bar at incoming end complete all as specified and directed.
S&F MCB 'C' series Double pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. Make:- Legrand Cat No 408628-36 or equivalent model of L&T/ C&S/ Indoasian
S&F MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. Make:- Legrand Cat No 408587-95 or equivalent model of L&T/ C&S/ Indoasian
M&L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trenches /poles/on wall complete including necessary cable glands, aluminium lugs duly crimped, termination etc all as specified and directed.
M&L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trenches /poles/on wall complete including necessary cable glands, aluminium lugs duly crimped, termination etc all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
Supply & Laying Sub Class 'B' Bricks,old size, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
M&L for Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification. GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC (1:2:4, type B-1) cover, of 450 x 450 mm complete all as specified and directed. (Make: ASHLOK / INDELEC / JMV / TERCEL).
Supply, fixing energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source connecting and testing LED Flood lights of 120 watts capacity and unique peanut lens to ensure uniform distribution complete all as specified and directed. (Make : Crompton/Philips/Havells)
Supply and errection of steel tubular swaged poles 9.0 metre long, type 410 SP-31 complete with cast iron base plate, final taper plug, bolts, nuts and screws, pole cap etc confirming to IS-2713 of 1980 including painting two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces and numbering to be done in black synthetic enamel paint complete all as specified and directed.
S&F junction box made of thermoplastic of size 200mm x 160mm x 98mm with knockouts for cable entry including terminals IP 65 protection complete all as specified and directed. (Make Hensal/syntex)
Supply and fixing street light bracket made out of 50x50x5mm angle iron 1.00 metre 1.50 Mtrlength with MS flat iron clamp of required shape with bolts nuts and washers complete all as specified and directed.
S&F flexible PVC insulated multicore FR PVC sheathed multistranded cable with bright annealed electrolytic bare copper conductor of size 1.5 sqmm 3 core for voltage grade upto 1100 volt in 25mm bore PVC conduit including fixing with sutable clamps, nut bolts etc. complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 with using 40 mm grade crushed stone aggregate as in beding of steel tubular poles (15 mm thick) with necessary form work as required complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 with using 20 mm grade crushed stone aggregate as in foundation, copping of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
S&F Air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F aluminium strip 25 x 3.15 mm with saddles fixinf scrcub etc for roof conductors down & above ground complete all as specified and directed.
S&F Galvanised iron strip 32 x 6 mm as continuity conductor burried in ground complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 3Nos 8mm dia 25 mm long hex head screw complete all asspecified and directed.
M&L for earthing complete of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgrated (Zinic & alloy coated) Zinic coated (80-100) microns with pure (99.9%) & alloy coating (200-250) microns earthing system confirming IS-3034 the outer and inner pipe should be 76.2mm & 41.9mm dia 3 mtr length zinic coated with additional special alloy coating 300mm on the topside for additional protection of the terminal the annular space between the pipes being filledup with compact fill(CF) (Crystalline conductive compound) the compact fill (CF) mixture which is machine pressed in the pipes should not disintgrate or collapse when outer pipe corrods, the inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrode/conductolite back fill compound (Ground enhancer)the BFC should dbe eco friendly it should not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pitcover for protection and safe guard of terminals. In area where soil condition is bad good earth is to be arranged to fill the excavated pits by mixing the same with BFC 4 bags (as per soil condition) extra perpit/unit. As earth electrode is the main component of the earthing system which is indirect contact with the ground and thus provides ameans of releasing or collecting earth leakage current. The materials should have a good electrical conductivity & anti corrosion properrty in wide range of soil condition complete and testing on completion including dismantlingh unserviceable earthing complete all as specified and directed Make ASHLOK Model ASEELor equivalent Note:- Earth result should be obtain minimum 1 Ohm.
M/S KAR CONSTRUCTION
MUKHERJEE ENTERPRISE
UNIVERSAL CONSTRUCTION
Paritosh Saha
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .