Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC AOC to lowest bid of M/s Sohtra and Co. | |
| 2 | L2₹34.2 L+₹5.1 L (17.4%)Rejected-Finance NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Being other than lowest bid | |
| 3 | L3₹36.1 L+₹7.0 L (24.2%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bid |
| Sl No | Description | Qty | Unit | sohtra and co L1 | MAHAJAN TRADING CO L2 | RAMAN KUMAR L3 |
|---|---|---|---|---|---|---|
| 1.00 | Cleaning and desludging of existing septic tanks / soakage wells of any capacity (10 users to 500 users) including inlet and outlet chambers, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means and removing waste material/ sludge etc. to a distance not exc 50 mtr including digging, burrying in ground, complete all as specified and directed.
Notes :-
(i) Work shall be done in foul conditions, necessary precautionary measures/ equipments to be adopted by the contractor.
(ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth.
(iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing manhole covers.
(iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt. | 100 | Cum | 100 ₹10,000 | 50 ₹5,000 Lowest | 50 ₹5,000 Lowest |
| 2.00 | Dewatering of existing septic tank of any capacioty (10 users to 500 user) including inlet and outlet chambers and soakage well, taking out sewage water by mechanical pump and equipment, filling in closed tank attached with tractore or truck etc. and removing the same out side from population area, complete all as specified and directed,
Notes :-
(i) Work shall be done in foul conditions, necessary precautionary measures/ equipments to be adopted by the contractor.
(ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth.
(iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing manhole covers.
(iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt. | 200 | Cum | 50 ₹10,000 Lowest | 50 ₹10,000 Lowest | 50 ₹10,000 Lowest |
| 3.00 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in any type of soil, complete all as specified and directed. | 100 | Cum | 380 ₹38,000 | 150 ₹15,000 | 100 ₹10,000 Lowest |
| 4.00 | Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr in depth but not exc 3.0 mtr in depth for foundation, laying of pipes, cables or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in any type of soil, complete all as specified and directed. | 20 | Cum | 400 ₹8,000 | 250 ₹5,000 | 100 ₹2,000 Lowest |
| 5.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. | 80 | Cum | 20 ₹1,600 Lowest | 20 ₹1,600 Lowest | 20 ₹1,600 Lowest |
| 6.00 | Removing excavated material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr from the starting point, complete all as specified and directed. | 40 | Cum | 20 ₹800 Lowest | 20 ₹800 Lowest | 20 ₹800 Lowest |
| 7.00 | Dismantling of cast iron drain pipes, jointed in cement mortar and taking out from trenches (if required) of 75/100mm bore pipes, complete all as specified and directed. | 200 | RM | 20 ₹4,000 | 1 ₹200 Lowest | 10 ₹2,000 |
| 8.00 | Demolition and breaking up of drain pipe of 150mm to 300mm dia (Salt glazed stoneware, AC or reinforced concrete), set in cement mortar, complete all as specified and directed. | 1,500 | RM | 5 ₹7,500 Lowest | 10 ₹15,000 | 15 ₹22,500 |
| 9.00 | M&L for concrete bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) including necessary shuttering and supports, complete all as specified and directed. | 780 | RM | 20 ₹15,600 Lowest | 80 ₹62,400 | 90 ₹70,200 |
| 10.00 | M&L for concrete bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) including necessary shuttering and supports, complete all as specified and directed. | 290 | RM | 30 ₹8,700 Lowest | 80 ₹23,200 | 100 ₹29,000 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
21 Feb 2026, 6:00 pmClosed
GE (North) Udhampur
Garrison Engineer (North) Udhampur PIN-901220 C/o 56 APO
SPECIAL REPAIRS TO SEWAGE LINE AND MISC WORK OF 5071 ASC BN (MT) UNIT AREA UNDER GE (NORTH) UDHAMPUR.
2026_MES_750561_1
GE/U(N)-112/2025-26
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (North) Udhampur
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (North) Udhampur
₹94,000
Yes
12 Mar 2026
30 Jan 2026
23 Feb 2026
30 Jan 2026
21 Feb 2026
14 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cleaning and desludging of existing septic tanks / soakage wells of any capacity (10 users to 500 users) including inlet and outlet chambers, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means and removing waste material/ sludge etc. to a distance not exc 50 mtr including digging, burrying in ground, complete all as specified and directed.
Notes :-
(i) Work shall be done in foul conditions, necessary precautionary measures/ equipments to be adopted by the contractor.
(ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth.
(iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing manhole covers.
(iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt. | 100 | Cum | - | - |
| 2 | Dewatering of existing septic tank of any capacioty (10 users to 500 user) including inlet and outlet chambers and soakage well, taking out sewage water by mechanical pump and equipment, filling in closed tank attached with tractore or truck etc. and removing the same out side from population area, complete all as specified and directed,
Notes :-
(i) Work shall be done in foul conditions, necessary precautionary measures/ equipments to be adopted by the contractor.
(ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth.
(iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing manhole covers.
(iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt. | 200 | Cum | - | - |
| 3 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in any type of soil, complete all as specified and directed. | 100 | Cum | - | - |
| 4 | Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr in depth but not exc 3.0 mtr in depth for foundation, laying of pipes, cables or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in any type of soil, complete all as specified and directed. | 20 | Cum | - | - |
| 5 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. | 80 | Cum | - | - |
| 6 | Removing excavated material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr from the starting point, complete all as specified and directed. | 40 | Cum | - | - |
| 7 | Dismantling of cast iron drain pipes, jointed in cement mortar and taking out from trenches (if required) of 75/100mm bore pipes, complete all as specified and directed. | 200 | RM | - | - |
| 8 | Demolition and breaking up of drain pipe of 150mm to 300mm dia (Salt glazed stoneware, AC or reinforced concrete), set in cement mortar, complete all as specified and directed. | 1,500 | RM | - | - |
| 9 | M&L for concrete bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) including necessary shuttering and supports, complete all as specified and directed. | 780 | RM | - | - |
| 10 | M&L for concrete bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) including necessary shuttering and supports, complete all as specified and directed. | 290 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TENDER112.pdf
Tender Documents • 1.05 MB
BOQ_840628.xls
BOQ • 1.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .