| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹27.0 LAdmitted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | -47.00% | ₹27.0 L | L1 | Admitted-Finance |
| 2 | L2₹31.9 LAdmitted-Finance | -37.37% | ₹31.9 L | L2 | Admitted-Finance |
| 3 | L3₹33.9 LAdmitted-Finance SHAHDARA | DELHI | 110095 | -33.40% | ₹33.9 L | L3 | Admitted-Finance |
| 4 | L4₹36.7 LAdmitted-Finance | -27.77% | ₹36.7 L | L4 | Admitted-Finance |
| 5 | L5₹39.2 LAdmitted-Finance NOT SPECIFIED | -22.99% | ₹39.2 L | L5 | Admitted-Finance |
Tender Value
₹50.9 L
EMD Value
₹1.0 L
Closing Date
24 Jun 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Comprehensive maintenance of Street Lights Flood Lights installed at underdeck of new RTR Flyover Naraina Flyover Moti Bagh Flyover and other roads and underdeck not maintained by DISCOM
2026_PWD_293705_1
24/EE(E)/ PWD EMD South West/2026-27
Open Tender
Electrical Works
365 days
works
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹1.0 L
1 Jul 2026
17 Jun 2026
24 Jun 2026
17 Jun 2026
24 Jun 2026
17 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Routine Maintenance of street lights, Decorative Lights, Tricolor & Flood Lights by using tower wagon, ladders & all other relevant suitable tools & plants required for smoothly, healthy and proper illumination on roads i/c dismantling the defective fittings and re-fixing the LED fitting on the existing street light pole of 8 to12 Mtr height, High Mast 16 to 30 Mtr height & under deck of flyover at a height of upto 6 Mtr after repairing the LED fittings with all electrical accessories i/c replacement of MCB, Relay, contactor, Timer MCCB & other related accessories, and replacement of defective wiring from pole window to fitting i/c providing & fixing of Pole window cover and supplying and laying of cables from pole to pole for smooth functioning of all the fittings after removing of block tile and cutting the road / hard rock / soil and making good the same with bitumen / cement concrete i/c dismantling and removing of accidental / damaged pole etc as and when required and also to prevent theft of electricity from street light i/c daily inspection of roads and submit the fortnightly inspection report to JE(E)/AE(E) and removing the defective/damage pole due to accident and handed over to the JE(E) store, Dhaula Kuan etc complete as reqd. and as per direction of Engineer-in-charge i/c Sundays & Holidays as per terms & conditions attached:` Location of Street Light:- (As per Inventory attached) (For 12 Months) | 23,364 | Points Per Month | 190 | ₹44,39,160 |
| 2Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS /HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 2.01 | 120 watt | 12 | Each | 2,178 | ₹26,136 |
| 2.02 | 150 watt | 32 | Each | 2,883 | ₹92,256 |
| 2.03 | 200 watt | 50 | Each | 4,100 | ₹2,05,000 |
| 3Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >8 5%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg -1 20deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 3.01 | 70 Watt | 20 | Each | 1,717 | ₹34,340 |
| 3.02 | 150 Watt | 20 | Each | 2,690 | ₹53,800 |
| 3.03 | 200 Watt | 10 | Each | 3,972 | ₹39,720 |
| 4Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >8 5%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.96 MB
BOQ_390394.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid