| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.7 LAccepted-Finance | 1 | Accepted-Finance Bidder quoted the less than the estimate Value | |
| 2 | 2₹3.8 L+₹2,747 (0.73%)Rejected-Finance | 2 | Rejected-Finance Bidder quoted the More than the estimate Value |
Tender Value
₹3.9 L
EMD Value
₹7,800
Closing Date
4 Mar 2025, 3:00 pmClosed
Commissioner
Commissioner Tiruppur City Municipal Corporation-641604
Supply and Delivery of 3 core 4 Sq.mm Submersible Cable and Extension of Borewell Water Distribution Pipe Line at Amarjothi Garden and SRG Nagar and Construction of Chamber at Sripathi Nagar and Velampalayam OHT opposite in ward No 12
2025_MAWS_526521_8
494 / 2024-25 / N / Z1 / EE, Tcmc
Open Tender
Civil Works - Water Works
Works
Tiruppur City Municipal Corporation
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,800
16 Apr 2025
21 Feb 2025
4 Mar 2025
21 Feb 2025
4 Mar 2025
21 Feb 2025
Amount
Earthwork excavation for foundation in all soils and sub soils except in hard rock requiring blasting and depositing on bank with initial lead of 10m and initial lift of 2m inclusive of shoring, shuttering, bailing out water wherever necessary, refilling the foundation with excavated earth other than sandy soil in layers of not more than 150mm thick layers well rammed and depositing the surplus earth within the compound in place shown by the departmental officers and clearing and levelling the site etc,. complete.
Plain Cement concrete 1:4:8 [one cement, four M-sand and eight course aggregates] using 40mm size Hard Broken/Machine crushed Granite Stone Jelly including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification.
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of 75mm thickness in RCC 1:2:4 (one cement, two M-Sand and four course aggregates) using 20mm size Hard Broken/Machine crushed Granite Stone Jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification.
Brick work In CM 1:5 mix using best Second Class Table Moulded Chamber Burnt Bricks 9"x4½"x3" having 350 kg/cm² compressive strength and 15% or less water absorbent in the period of 24hours immersement and confirming to ISI specifications including finishing, curing etc., complete complying with standard specification.
Plain Cement concrete in 1:3:6 [one cement, three M-sand and six course aggregate] using 20mm size Hard Broken/Machine crushed Granite Stone Jelly including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification.
Plastering with cement mortar 1:5 mix (one cement five P-sand), 12mm thick in all floors using clean screened M-Sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting from other damages till setting of mortar etc., complete complying with standard specification.
Supply and delivery of 50mm UPVC Pipe with IS specification etc., complete.
Supply and delivery of 63mm PVC Pipe with IS specification etc., complete.
Supply and delivery of following size of PVC / G.I Pipes and Specials with IS specification etc., complete.
50mm G.I Union
50mm G.M Non Return Valve
63mm PVC Elbow
63mm PVC Tee
20mm G.I Pipe
20mm G.I Elbow
20mm G.I Tee
Supply of PVC insulated and sheathed 4.0 Sq.mm 3 core flat type copper cable conforming to IS 694 / 1990 etc., complete
Earth work excavation and depositing on bank with initial lead and lift as initial of 10 M and lift of 2 M in narrow trenches for laying of pipes for water supply works in Hard stiff clay, stiff black cotton, hard red earth shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravel soil including refilling the sides of foundation in layer of 15m thick watering ramming depositing the surplus earth in the premises as directed by the departmental officers etc., complete complying with standard specification.
Lowering of 63mm (2") PVC Pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
Add G.S.T. @ 18%
M.Palanisamy (BID ID -1260215)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .